Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20063D550 + (ML20063D550)
- ML20063D554 + (ML20063D554)
- ML20063D556 + (ML20063D556)
- 05000413/LER-1993-012-02, :on 931225,Unit 1 Entered Mode 3,hot Standby from Mode 4,hot Shutdown W/Auxiliary Feedwater Pump Inoperable.Caused by Personnel Error.Ts Reviewed & Revised + (ML20063D558)
- ML20063D564 + (ML20063D564)
- ML20063D568 + (ML20063D568)
- ML20063D577 + (ML20063D577)
- ML20063D578 + (ML20063D578)
- ML20063D579 + (ML20063D579)
- ML20063D580 + (ML20063D580)
- ML20063D585 + (ML20063D585)
- ML20063D588 + (ML20063D588)
- ML20063D592 + (ML20063D592)
- ML20063D601 + (ML20063D601)
- 0CAN028210, Forwards Annual Occupational Radiation Exposure Rept, Personnel Whole Body Exposure for CY81, Per 10CFR20.407 + (ML20063D603)
- ML20063D606 + (ML20063D606)
- ML20063D607 + (ML20063D607)
- ML20063D608 + (ML20063D608)
- ML20063D614 + (ML20063D614)
- ML20063D624 + (ML20063D624)
- ML20063D626 + (ML20063D626)
- ML20063D629 + (ML20063D629)
- 05000280/LER-1981-005-03, /03L-0:on 810301,radiation Monitor Recorder RR-175 Found Printing Erratically.Caused by Dirty Slidewire Resistor in Circuit That Controls Positioning of Printing Device.Resistor Cleaned & Recorder Returned to Svc + (ML20063D634)
- 05000280/LER-1981-006-03, /03L-0:on 810306,alarm Setpoint for Component Cooling Water Radiation Monitor RM-CC-106 Found to Be Greater than Twice Background.Caused by Instrument Drift. Monitor Reset to Proper Setpoint & Returned to Svc + (ML20063D636)
- ML20063D649 + (ML20063D649)
- ML20063D654 + (ML20063D654)
- ML20063D662 + (ML20063D662)
- ML20063D663 + (ML20063D663)
- ML20063D669 + (ML20063D669)
- ML20063D671 + (ML20063D671)
- ML20063D678 + (ML20063D678)
- ML20063D681 + (ML20063D681)
- ML20063D684 + (ML20063D684)
- ML20063D687 + (ML20063D687)
- ML20063D691 + (ML20063D691)
- ML20063D693 + (ML20063D693)
- ML20063D703 + (ML20063D703)
- 05000331/LER-1982-035, Forwards LER 82-035/03L-0 + (ML20063D711)
- ML20063D717 + (ML20063D717)
- RC-94-0017, Provides 10CFR50.46 30 Day Rept Followup,Consisting of Schedule for Resolution of Safety Injection in Broken Loop Issues,As Committed to in Util + (ML20063D719)
- 05000331/LER-1982-035-03, /03L-0:on 820607,reactor Core Isolation Cooling Steam Line High Flow Pressure Differential Indicating Switches PDTS 2441 & 2442 Tripped Low.Caused by Instrument Drift.Switches Recalibr.Design Change Underway + (ML20063D729)
- 05000317/LER-1982-028, Forwards LER 82-028/03L-0 + (ML20063D733)
- ML20063D745 + (ML20063D745)
- ML20063D747 + (ML20063D747)
- 05000249/LER-1982-025, Forwards LER 82-025/03L-0 + (ML20063D750)
- ML20063D761 + (ML20063D761)
- 05000305/LER-1982-018, Forwards LER 82-018/03L-0 + (ML20063D762)
- ML20063D763 + (ML20063D763)
- 05000361/LER-1982-070-03, /03L-0:on 820720,while in Mode 3,main Steam Safety Valves Found to Have Pressure Setpoints Lower than Tech Spec.Caused by Instrument Drift & Limitations in Procedure Used in Performing Initial Adjustment & 18-month Tests + (ML20063D770)
- ML20063D771 + (ML20063D771)
- 05000305/LER-1982-018-03, /03L-0:on 820602,1A RHR Pump Taken Out of Svc to Repair Excessive Shaft Seal Leakage.Caused by Scored Shaft & Excessive Clearances on Pump Wear Rings.New Shaft,Impeller, Shaft Sleeve & Mechanical Seal Installed + (ML20063D772)