Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000318/LER-1982-021-03, LER-021/03L-0:on 820714,22B Safety Injection Tank Pressure Found Decreased to 197 Psig on 820427.Caused by Loop Isolator Failure.Isolator Replaced + (ML20062N318)
- ML20062N339 + (ML20062N339)
- ML20062N347 + (ML20062N347)
- JAFP-82-0850, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/82-06.Corrective Actions:Operator Stationed at Portable Monitor to Continuously Monitor Containment Atmosphere + (ML20062N360)
- ML20062N361 + (ML20062N361)
- JAFP-82-0543, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/82-01.Corrective Actions:Valves 250C & BAS-4 Repositioned to Agree W/Lineup List & Procedures Reviewed for Control of Plant Status + (ML20062N365)
- ML20062N378 + (ML20062N378)
- ML20062N388 + (ML20062N388)
- B14716, Requests Relief from ASME Boiler & Pressure Vessel Code Section XI Requirements,Per GL 90-05.Description of Actions Taken by Util to Repair Leak in SWS Piping Line 3SWP-010-028-3 as Alternative to IWA-4000/70005 Repair + (ML20062N390)
- 05000305/LER-1982-002, Forwards Updated LER 82-002/03X-1 & LERs 82-024/03L-0 & 82-025/03L-0 + (ML20062N391)
- ML20062N404 + (ML20062N404)
- 05000305/LER-1982-002-03, During Normal Operation, Pressurizer Level Transmitter LT427 Found Out of Spec.Caused by Instrument Drift.Transmitter Recalibr.Barton Transmitters Will Be Changed as Part of long-term Upgrade + (ML20062N408)
- ML20062N412 + (ML20062N412)
- LIC-93-0299, Forwards Application for Amend to License DPR-40,revising TS Surveillance Test Frequency from Monthly to Quarterly for Several Channel Functional Tests for RPS & ESF I&Cs,Per GL 93-05,based on NRC Approval of TR CEN-327-A & Tr,Suppl 1 + (ML20062N413)
- ML20062N417 + (ML20062N417)
- 05000305/LER-1982-024-03, /03L-0:on 820716,while at Full Power,Overpower Delta T Channel 3 Rod Stop Alarm Observed Cycling in & Out. Caused by Malfunction of Tavg Signal Conditioner Causing Channel to Drift.Spare Signal Box Installed & Calibr + (ML20062N420)
- ML20062N421 + (ML20062N421)
- ML20062N427 + (ML20062N427)
- ML20062N432 + (ML20062N432)
- 05000305/LER-1982-025-03, /03L-0:on 820716,during Document Review,Waste Disposal Liquid Effluent Monitor Found Indicating Low.Caused by Weak Detection Tube on Monitor.Tube Replaced & Detector Recalibr + (ML20062N435)
- 05000317/LER-1982-041, Forwards LER 82-041/03L-0 + (ML20062N440)
- 05000317/LER-1982-041-03, /03L-0:on 820713,channel a High Power,Thermal Margin/Low Pressure & Axial Shape Index Trip Units Bypassed to Allow Failing Hot Leg Temp Element Signal to Be Removed from Reactor Protective Sys.Caused by Changing Temp Element + (ML20062N449)
- ML20062N463 + (ML20062N463)
- ML20062N467 + (ML20062N467)
- ML20062N473 + (ML20062N473)
- ML20062N476 + (ML20062N476)
- ML20062N505 + (ML20062N505)
- ML20062N506 + (ML20062N506)
- 05000315/LER-1982-056, Forwards LER 82-056/03L-0 + (ML20062N510)
- ML20062N511 + (ML20062N511)
- ML20062N514 + (ML20062N514)
- ML20062N521 + (ML20062N521)
- ML20062N524 + (ML20062N524)
- 05000315/LER-1982-056-03, /03L-0:on 820717,during Surveillance Test of Automatic Load Sequence Timing Relays,Three Relay Timers Exceeded Allowable Tolerance.Caused by Instrument Drift. Timers Adjusted.Use of New Solid State Relay Under Review + (ML20062N538)
- ML20062N540 + (ML20062N540)
- ML20062N541 + (ML20062N541)
- ML20062N545 + (ML20062N545)
- ML20062N548 + (ML20062N548)
- ML20062N551 + (ML20062N551)
- 05000315/LER-1982-057, Forwards LER 82-057/03L-0 + (ML20062N552)
- ML20062N561 + (ML20062N561)
- ML20062N579 + (ML20062N579)
- ML20062N581 + (ML20062N581)
- ML20062N585 + (ML20062N585)
- ML20062N588 + (ML20062N588)
- ML20062N590 + (ML20062N590)
- ML20062N595 + (ML20062N595)
- ML20062N603 + (ML20062N603)
- ML20062N607 + (ML20062N607)
- ML20062N619 + (ML20062N619)
- ML20062N624 + (ML20062N624)