Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20052A644 + (ML20052A644)
- ML20052A647 + (ML20052A647)
- ML20052A649 + (ML20052A649)
- 05000348/LER-1982-013, Forwards LER 82-013/03L-0 + (ML20052A650)
- PNO-II-82-042, on 820417,fire Discovered in Steam Generator Repair Bldg Located Near Unit 1.Both Reactors Not Affected by Fire.Fire Extinguished by Surry County Fire Dept & Plant Fire Brigade.Cause Not Known + (ML20052A655)
- ML20052A656 + (ML20052A656)
- 05000348/LER-1982-013-03, /03L-0:on 820317,containment Atmosphere Activity Monitors R-11 (Particulate Monitor) & R-12 (Gaseous Monitor) Declared Inoperable Due to Failure of Vacuum Pump.Caused by Failed Outboard Pump.Filter & Gasket Replaced + (ML20052A657)
- ML20052A659 + (ML20052A659)
- 05000364/LER-1982-005-03, /03L-0:on 820226,4160-volt B Train Ac Electrical Power Circuit Declared Inoperable When Emergency Bus 2G de-energized.Bus 2G de-energized When Breaker 2-DG15 Opened. Cause Under Investigation + (ML20052A661)
- ML20052A662 + (ML20052A662)
- 05000364/LER-1982-008-03, /03L-0:on 820226,instrumentation Loop Associated w/LI-485 (Steam Generator B Level Indication) Declared Inoperable When Reading Was Out of Tolerance W/Other Channels.Caused by Obstruction in Ref Leg + (ML20052A663)
- ML20052A664 + (ML20052A664)
- ML20052A665 + (ML20052A665)
- 05000364/LER-1982-009-03, /03L-0:on 820228,instrumentation Loop Associated w/FT-474 (Steam Generator a Flow Transmitter) Declared Inoperable.Caused by Leaking Equalizing Valve.Valve Stem Repaired + (ML20052A667)
- ML20052A668 + (ML20052A668)
- ML20052A669 + (ML20052A669)
- ML20052A670 + (ML20052A670)
- 05000364/LER-1982-010-03, /03L-0:on 820226,instrumentation Loop Associated w/LI-474 (Steam Generator a Level Indicator) Declared Inoperable.Caused by Loss of Necessary Level in Ref Leg While Steam Generator Not in Svc.Leg Refilled + (ML20052A671)
- ML20052A673 + (ML20052A673)
- IR 05000305/1981027 + (ML20052A674)
- ML20052A677 + (ML20052A677)
- ML20052A679 + (ML20052A679)
- ML20052A682 + (ML20052A682)
- ML20052A683 + (ML20052A683)
- ML20052A684 + (ML20052A684)
- ML20052A686 + (ML20052A686)
- ML20052A687 + (ML20052A687)
- ML20052A688 + (ML20052A688)
- ML20052A690 + (ML20052A690)
- ML20052A691 + (ML20052A691)
- ML20052A692 + (ML20052A692)
- ML20052A693 + (ML20052A693)
- ML20052A694 + (ML20052A694)
- ML20052A695 + (ML20052A695)
- AECM-82-146, Advises That Bailey & Rochester Balance of Plant/Pg CC Devices Are Adequately Qualified to Ensure Essential post- Accident Info Will Be Provided to Control Room Operators During Interim Operations Per SER Item 1.10(17) + (ML20052A696)
- ML20052A697 + (ML20052A697)
- ML20052A698 + (ML20052A698)
- ML20052A700 + (ML20052A700)
- ML20052A701 + (ML20052A701)
- ML20052A704 + (ML20052A704)
- ML20052A706 + (ML20052A706)
- ML20052A709 + (ML20052A709)
- ML20052A710 + (ML20052A710)
- ML20052A712 + (ML20052A712)
- ML20052A713 + (ML20052A713)
- ML20052A714 + (ML20052A714)
- ML20052A715 + (ML20052A715)
- ML20052A717 + (ML20052A717)
- ML20052A719 + (ML20052A719)
- ML20052A722 + (ML20052A722)
- ML20052A723 + (ML20052A723)