- ML20052A523 + (ML20052A523)
- 05000366/LER-1982-013-03, /03L-0:on 820214,while Performing Routine Surveillance,Sample Pump for Primary Containment Gaseous Monitoring Sys Was Inoperable.Caused by Bearing Failure Due to Normal Wear.Pump Replaced + (ML20052A525)
- ML20052A526 + (ML20052A526)
- 05000321/LER-1982-011, Forwards LER 82-011/03L-0 + (ML20052A529)
- ML20052A531 + (ML20052A531)
- ML20052A532 + (ML20052A532)
- ML20052A533 + (ML20052A533)
- ML20052A534 + (ML20052A534)
- 05000321/LER-1982-011-03, /03L-0:on 820212,following Reactor Core Isolation Cooling Initiation,Smoke Discovered Coming from Diagonal. Caused by Oil Leak from 3/8-inch Threaded Pipe That Had Vibrated Loose.Pipe Tightened + (ML20052A536)
- ML20052A538 + (ML20052A538)
- ML20052A539 + (ML20052A539)
- PNO-II-82-038, on 820412,reactor Shut Down Because of Excessive Vibration in C Low Pressure Turbine While at 25% Power.Caused by Loose 13th Stage Shroud.Unit Had Returned to Svc After Refueling Outage Previous Day + (ML20052A540)
- PNO-V-82-019, on 820423,util Executive Board Will Meet to Consider Recommendations to Suspend Const Until Troubles Solved & Region Requires More Generating Capacity + (ML20052A541)
- IR 05000029/1982005 + (ML20052A542)
- PNO-V-82-014D, verifying Current Status of HPI Nozzle Repairs.Nozzle a Radiographic Test of safe-end to Nozzle Weld Good.Penetrant Test & Ultrasonic Test to Follow.Thermal Sleeve a Hard Rolled to safe-end & Contact Rolled to Nozzle + (ML20052A543)
- ML20052A544 + (ML20052A544)
- 05000366/LER-1982-028, Forwards LER 82-028/01T-0 + (ML20052A546)
- PNO-II-82-037, on 820414,contractor Security Guard Accidentally Shot Self in Leg While Working W/Gun + (ML20052A548)
- 05000366/LER-1982-028-01, /01T-0:on 820402,standby Gas Treatment Filter Train 2T46-D001B Found Out of Compliance W/Tech Spec.Caused by Error in Testing Procedure.Charcoal Replaced & Tested. Procedure Revised + (ML20052A549)
- ML20052A556 + (ML20052A556)
- PNO-II-82-036, on 820409,ultrasonic Testing Indicated Two Possible Irregularities Near or on Outside Surface of Pressure Vessel.Metallurgist Sent to Site to Monitor Action. Unit Defueled + (ML20052A557)
- 05000366/LER-1982-012, Forwards LER 82-012/03L-0 + (ML20052A558)
- ML20052A560 + (ML20052A560)
- ML20052A563 + (ML20052A563)
- ML20052A564 + (ML20052A564)
- 05000366/LER-1982-012-03, /03L-0:on 820126,reactor Core Isolation Cooling Turbine Trip & Throttle Valve Would Not Electronically Trip Closed Upon Receipt of Hi Dp Signal.Caused by Oxidized Contacts on Trip Coil Assembly.Contacts Cleaned + (ML20052A565)
- PNO-V-82-017A, updating Info Re a & B Auxiliary Feedwater once-through Steam Generator Header Problem.Fiberoptics Exam of B Header Showed Deformation W/Pin in Place.Similar Exam of a Header to Be Performed + (ML20052A566)
- ML20052A567 + (ML20052A567)
- ML20052A568 + (ML20052A568)
- 05000339/LER-1982-016, Forwards LER 82-016/03L-0 + (ML20052A569)
- 05000324/LER-1982-054, Forwards LER 82-054/03L-0 + (ML20052A571)
- ML20052A573 + (ML20052A573)
- ML20052A574 + (ML20052A574)
- ML20052A575 + (ML20052A575)
- ML20052A577 + (ML20052A577)
- 05000324/LER-1982-054-03, /03L-0:on 820314,reactor Low Level Switch 2-B21-LIS-NO17D-1 Actuated at Level Below Reportable Limit. Caused by Instrument Drift.Switch Recalibr & Returned to Svc + (ML20052A578)
- ML20052A579 + (ML20052A579)
- 05000366/LER-1982-014, Forwards LER 82-014/03L-0 + (ML20052A581)
- IR 05000395/1982027 + (ML20052A583)
- 05000325/LER-1982-040, Forwards LER 82-040/03L-0 + (ML20052A584)
- 05000339/LER-1982-016-03, /03L-0:on 820323,lower Main Bearing 14 in Emergency Diesel 2-EE-EG-1J Found Scored.Caused by Lack of Lubrication Due to Disconnected Lubrication Oil Line. Bearing Replaced + (ML20052A586)
- ML20052A587 + (ML20052A587)
- ML20052A589 + (ML20052A589)
- 05000366/LER-1982-014-03, /03L-0:on 820128,results of Primary Containment Leakage Test on D/W Personnel Airlock Interspace Determined Leak Rate Exceeded Tech Specs.Caused by Damaged Shaft & Seal Assembly on Outer Air Lock Door + (ML20052A590)
- ML20052A591 + (ML20052A591)
- ML20052A592 + (ML20052A592)
- ML20052A593 + (ML20052A593)
- ML20052A594 + (ML20052A594)
- ML20052A595 + (ML20052A595)
- 05000325/LER-1982-040-03, /03L-0:on 820319,primary Containment Multipoint Temp Recorder 1-CAC-TR-1258 Printed Erratically.Caused by Fouled Electrical Contacts in Recorder Point Select Relay. Contacts Cleaned + (ML20052A597)