- 05000324/LER-1982-005, Forwards LER 82-005/01T-0 + (ML20040G534)
- ML20040G536 + (ML20040G536)
- ML20040G537 + (ML20040G537)
- 05000259/LER-1981-094, Forwards LER 81-094/03L-0 + (ML20040G538)
- 05000280/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040G540)
- 05000339/LER-1982-004, Forwards LER 82-004/03L-0 + (ML20040G542)
- 05000324/LER-1982-005-01, /01T-0:on 820116,both RHR Svc Water Loops Inoperable,Rendering RHR Shutdown & Suppression Pool Cooling Modes Inoperable.Caused by Loop Pumps Failure Due to Plugging of Sensing Line to Suction Header Pressure Switch + (ML20040G546)
- ML20040G547 + (ML20040G547)
- ML20040G548 + (ML20040G548)
- 05000280/LER-1982-001-03, /03L-0:on 820106,spurious Safety Injection Caused Phase 1 Containment Isolation.Trip Valve TV-CC-109B Failed to Close.Caused by Teflon Tape Preventing Operation of 3-way SOV That Controls TV-CC-109B + (ML20040G549)
- 05000272/LER-1982-004-03, /03L-0:on 820109,primary Coolant Water Sample Results Indicated Excessive Boron Concentration,Constituting Positive Reactivity Change.Caused by Water Draining Out of Steam Generator Tubes.Rcs Rapid Boration Initiated + (ML20040G550)
- 05000259/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040G551)
- 05000259/LER-1981-094-03, /03L-0:on 811226,B Dihydrogen Dioxide Sample Return Pump Tripped & Would Not Reset.Caused by Locked Cam Bearing Due to Misalignment or Insufficient Lubrication. Cams & Cam Bearings Replaced + (ML20040G553)
- 05000339/LER-1982-004-03, /03L-0:on 820110,containment Isolation Steam Operator Blowdown Valve TV-BD-200C Would Not Remain Closed from Control Room.Caused by Excessive Moisture in Limit Switch Housing.Housing Drained + (ML20040G554)
- ML20040G555 + (ML20040G555)
- ML20040G556 + (ML20040G556)
- 05000336/LER-1982-003, Forwards LER 82-003/03L-0 + (ML20040G558)
- 05000336/LER-1982-003-03, /03L-0:on 820104,fan F394 Tripped on Overload, Rendering Radiation Monitors 8123A & B Inoperable.Caused by Seized Bearings Due to Lack of Lubricaton.Blower Replaced. Proper Drainplug Installation Will Be Verified + (ML20040G562)
- 05000364/LER-1981-053-03, /03L-0:on 811210,diesel Generator 2C Failed to Start.Caused by Personnel Closing Air Start Header Isolation Valves Instead of Air Header Cross Connect Valves.Valves Realigned + (ML20040G563)
- 05000259/LER-1982-001-03, /03L-0:on 820103,meteorological Instrumentation O-Tdr-90-103 Air Temp Delta T & O-XR-90-102-1 (30 Ft Air Speed) Failed.Caused by Lightning Damage to Transistors Q3 & Q4 & Blown Fuses in Panel 9-34 & at Meterological Station + (ML20040G564)
- ML20040G565 + (ML20040G565)
- 05000259/LER-1982-002, Forwards LER 82-002/03L-0 + (ML20040G566)
- ML20040G568 + (ML20040G568)
- 05000364/LER-1981-055-03, /03L-0:on 811208,2B Recombiner Oxygen Inlet Analyzer Declared Inoperable.Caused by Faulty Analyzer Cell. Cell Replaced & Analyzer Recalibr + (ML20040G569)
- 05000272/LER-1982-003-03, /03L-0:on 820106,1B & 1C Diesels Locked Out, Rendering Diesels Inoperable at Same Time.On 820106,diesel Generator 1C Declared Inoperable While Diesel 1B Out of Svc for Maint.Caused by Misinterpretation of Lockout Switch Tag + (ML20040G570)
- 05000266/LER-1982-002, Forwards LER 82-002/03L-0 + (ML20040G571)
- ML20040G573 + (ML20040G573)
- ML20040G574 + (ML20040G574)
- 05000249/LER-1982-003, Forwards LER 82-003/03L-0 + (ML20040G576)
- 05000259/LER-1982-002-03, /03L-0:on 820106,drywell High Pressure Switch 1-PS-64-58C Found Isolated.Apparently Caused by Performance of Surveillance Instruction 4.2.B.5.Switch Returned to Normal & All Other Valving Involved Verified Correct + (ML20040G578)
- ML20040G579 + (ML20040G579)
- 05000266/LER-1982-002-03, /03L-0:on 820112,during Hot shutdown,1PT-469 Steam Generator Pressure Transmitter Isolated by Maint Personnel Due to Leaking Coupling.Pressure Sensing Tubing Showed Signs of Steam Leak Due to Freezing + (ML20040G580)
- 05000338/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040G581)
- ML20040G583 + (ML20040G583)
- 05000304/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040G584)
- ML20040G586 + (ML20040G586)
- ML20040G587 + (ML20040G587)
- 05000249/LER-1982-003-03, /03L-0:on 820115,during Steam Line Area Temp Switch Calibr Surveillance During Refueling Outage,Switch 3-261-16C Exceeded Tech Specs Limit of Less than or Equal to 200 F.Caused by Defective Temp Sensing Bulb.Switch Replaced + (ML20040G588)
- ML20040G589 + (ML20040G589)
- 05000304/LER-1982-001-03, /03L-0:on 820109,during Power operation,2C Steam Generator Pressure Channel 524 Failed High.Caused by Frigid Air Entering Transmitter Location Via Containment Tendon Tunnel Resulting in Frozen Sensing Line.Line Thawed + (ML20040G590)
- 05000338/LER-1982-001-03, /03L-0:on 820107,power Range Detector N-44 Drifted Low & Was Declared Inoperable.Quadrant Power Tilt Ratio Found Below Tech Spec Limit.Caused by Faulty Power Range Detector.Detector to Be Replaced During Refueling Outage + (ML20040G591)
- ML20040G592 + (ML20040G592)
- ML20040G593 + (ML20040G593)
- ML20040G594 + (ML20040G594)
- ML20040G595 + (ML20040G595)
- 05000339/LER-1982-002, Forwards LER 82-002/03L-0 + (ML20040G596)
- ML20040G598 + (ML20040G598)
- ML20040G599 + (ML20040G599)
- ML20040G601 + (ML20040G601)
- 05000305/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040G603)
- ML20040G605 + (ML20040G605)