Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20035G269 + (ML20035G269)
- ML20035G271 + (ML20035G271)
- ML20035G272 + (ML20035G272)
- ML20035G273 + (ML20035G273)
- ML20035G277 + (ML20035G277)
- ML20035G280 + (ML20035G280)
- RC-93-0097, Forwards 1992 Santee Cooper Annual Rept + (ML20035G284)
- ML20035G286 + (ML20035G286)
- ML20035G289 + (ML20035G289)
- ML20035G290 + (ML20035G290)
- ML20035G291 + (ML20035G291)
- ML20035G293 + (ML20035G293)
- 05000327/LER-1993-007, :on 930324,inadvertent Actuation of Containment Isolation Valve Occurred.Caused by Personnel Error. Individuals Involved Counseled & Operators Restored Affected Equipment to Svc + (ML20035G298)
- IR 05000213/1993002 + (ML20035G299)
- ML20035G300 + (ML20035G300)
- ML20035G304 + (ML20035G304)
- ML20035G305 + (ML20035G305)
- 05000328/LER-1993-004-01, :on 930323,discovered That Surveillance Interval Specified in TS 4.6.5.1 Exceeded.Caused by Ineffective Communication Between Chemistry Personnel. Procedure Revised + (ML20035G315)
- ML20035G323 + (ML20035G323)
- ML20035G325 + (ML20035G325)
- ML20035G328 + (ML20035G328)
- HL-3255, 1992 Annual Radiological Environ Surveillance Rept. W/ + (ML20035G329)
- ML20035G330 + (ML20035G330)
- ML20035G331 + (ML20035G331)
- ML20035G332 + (ML20035G332)
- ML20035G340 + (ML20035G340)
- ML20035G346 + (ML20035G346)
- ML20035G349 + (ML20035G349)
- 05000321/LER-1993-002-03, :on 930401,experienced Setpoint Drift in Excess of Tolerance Specified by Ist.Caused by Corrosion Induced Bonding of Pilot Valve Disc & Seat.Sys Installed to Provide Redundant Electrical Actuation Signals + (ML20035G351)
- PNO-I-93-021, on 930419,contamination Identified in Several Areas on Floor of Radioactive Matl Lab on Second Floor of Bldg.Caused by Spill of Approx .57 Mci.Areas on First Floor Have Been Decontaminated.Commonwealth of Ma Notified + (ML20035G352)
- ML20035G353 + (ML20035G353)
- ML20035G356 + (ML20035G356)
- ML20035G358 + (ML20035G358)
- ML20035G359 + (ML20035G359)
- ML20035G361 + (ML20035G361)
- NG-93-1551, Monthly Operating Rept for Mar 1993 for Duane Arnold Energy Ctr + (ML20035G364)
- ML20035G365 + (ML20035G365)
- ML20035G366 + (ML20035G366)
- IR 05000266/1993006 + (ML20035G368)
- ML20035G369 + (ML20035G369)
- ML20035G371 + (ML20035G371)
- 05000416/LER-1993-002, :on 930322,two Electrical Circuits Installed Through Containment Electrical Penetration Not Identified in Ts,Resulting in No Functional Testing of Circuit Breaker Protection Documented.Protection Device Tested + (ML20035G375)
- IR 05000219/1993004 + (ML20035G376)
- ML20035G378 + (ML20035G378)
- IR 05000346/1993005 + (ML20035G380)
- ML20035G381 + (ML20035G381)
- ML20035G383 + (ML20035G383)
- ML20035G386 + (ML20035G386)
- ML20035G387 + (ML20035G387)
- ML20035G388 + (ML20035G388)
- IR 05000254/1993008 + (ML20035G389)