- IR 05000443/1981009 + (ML20032D347)
- 05000267/LER-1981-066-03, /03L-0:on 811020,during Plant Startup,Emergency Diesel Generator Set Taken Out of Svc W/O Previously Verifying Other Diesel Generator Set Operable.Caused by Misinterpretation of LCO 4.6.1(d) + (ML20032D350)
- ML20032D351 + (ML20032D351)
- 05000206/LER-1981-025-01, /01T-0:on 811025,ball Valve CV-534 Did Not Close Automatically on Initiation of Containment Isolation Signal.On 811101,containment Isolation Valve CV-102 Did Not Close.Caused by Sticking Relays in Closing Circuits + (ML20032D352)
- ML20032D357 + (ML20032D357)
- 05000312/LER-1981-052, Forwards LER 81-052/03L-0.Detailed Event Analysis Submittted + (ML20032D359)
- ML20032D361 + (ML20032D361)
- 05000266/LER-1981-015, Updated LER 81-015/01T-1:on 811010,high & Low Head Safety Injection Check Valve Leakage Test Indicated Leakage in Excess of Acceptable Criteria for 1-853C.Cause Not Stated. Affected Line Flushed & 1-853C Retested + (ML20032D362)
- ML20032D363 + (ML20032D363)
- 05000312/LER-1981-052-03, /03L-0:on 811005,nuclear Svc Raw Water Pump B (P-472B)tripped W/O Alarms or Target Drops.Cause Not Found. Pump Restarted & Quarterly Surveillance Test Run W/O Problems + (ML20032D364)
- PNO-I-81-120, on 811104,licensee Reported Loss of Six Ir-192 Seeds & Ribbon After 811027 Removal from Patient.Personnel Interviewed Patient & Surveyed Areas W/O Finding Seeds.Addl Survey Planned + (ML20032D365)
- ML20032D366 + (ML20032D366)
- ML20032D368 + (ML20032D368)
- 05000344/LER-1981-024, Forwards LER 81-024/03L-0.Detailed Event Analysis Encl + (ML20032D369)
- ML20032D371 + (ML20032D371)
- ML20032D372 + (ML20032D372)
- ML20032D373 + (ML20032D373)
- 05000344/LER-1981-024-03, /03L-0:on 811003,emergency Diesel Generator Declared Inoperable Due to Blown Fuse & Loss of Dc Power. Caused by Failure of Indicator Lamp Socket.Lamp Socket & Dc Fuse Replaced + (ML20032D374)
- ML20032D375 + (ML20032D375)
- ML20032D376 + (ML20032D376)
- ML20032D377 + (ML20032D377)
- 05000344/LER-1981-025, Forwards LER 81-025/03L-0.Detailed Event Analysis Encl + (ML20032D378)
- ML20032D380 + (ML20032D380)
- ML20032D383 + (ML20032D383)
- ML20032D384 + (ML20032D384)
- 05000344/LER-1981-025-03, /03L-0:on 811104,power to Preferred Instrument Bus Y11 Lost for 1 Minute Due to Failure of Output Current Sensing Relay on Associated Static Inverter.Caused by Normal Relay end-of-life.Relay Replaced + (ML20032D385)
- ML20032D386 + (ML20032D386)
- ML20032D389 + (ML20032D389)
- ML20032D390 + (ML20032D390)
- ML20032D391 + (ML20032D391)
- ML20032D392 + (ML20032D392)
- ML20032D394 + (ML20032D394)
- ML20032D395 + (ML20032D395)
- 05000368/LER-1981-037, Forwards LER 81-037/03L-0 + (ML20032D397)
- ML20032D399 + (ML20032D399)
- IR 05000254/1981020 + (ML20032D400)
- 05000368/LER-1981-037-03, /03L-0:on 811006,small Pipe Hanger for a Low Pressure Safety Injection Pump Cooler Outlet Piping Discovered Missing.Caused by Const Mod Removing Hanger Due to Interference.Hanger Replaced + (ML20032D401)
- ML20032D404 + (ML20032D404)
- 05000368/LER-1981-038, Forwards LER 81-038/03L-0 + (ML20032D408)
- ML20032D410 + (ML20032D410)
- IR 05000213/1981013 + (ML20032D411)
- ML20032D414 + (ML20032D414)
- ML20032D416 + (ML20032D416)
- ML20032D417 + (ML20032D417)
- ML20032D419 + (ML20032D419)
- IR 05000213/1981009 + (ML20032D420)
- ML20032D421 + (ML20032D421)
- ML20032D422 + (ML20032D422)
- ML20032D423 + (ML20032D423)
- ML20032D424 + (ML20032D424)
- ML20032D425 + (ML20032D425)