- 05000324/LER-1983-005, Forwards LER 83-005/03L-0 + (ML20028G597)
- ML20028G598 + (ML20028G598)
- 05000324/LER-1983-005-03, /03L-0:on 830110,both Personnel Secondary Containment Airlock Doors,Located on 50-ft Elevation Northeast Wall,Found Inoperable Due to Excessive Leakage Past Seals.Caused by Damaged Sealing Gaskets + (ML20028G600)
- 05000416/LER-1983-019, Forwards LER 83-019/03L-0 + (ML20028G601)
- ML20028G602 + (ML20028G602)
- 05000416/LER-1983-019-03, /03L-0:on 830112 & 20,one Smoke Detector in Zone 1-15 & Eight Detectors in Zone 2-18 Covered During Planned Maint Functions to Prevent False Alarms or Damage to Unit. Detectors Uncovered After Maint Completed + (ML20028G603)
- 05000335/LER-1983-004, Forwards LER 83-004/03L-0 + (ML20028G604)
- ML20028G605 + (ML20028G605)
- 05000368/LER-1983-001, Forwards LER 83-001/03L-0 + (ML20028G606)
- ML20028G607 + (ML20028G607)
- 05000335/LER-1983-004-03, /03L-0:on 830114,auxiliary Feedwater Pump C Trip & Throttle Valve Not Manually Reset.Caused by Operator Oversight.Operator Counseled on Correct Trip Operation + (ML20028G608)
- 05000368/LER-1983-001-03, /03L-0:on 830106,during Mode 1,control Room Emergency Air Conditioner 2VE-1B Failed Surveillance Test Due to Excessive Compressor Cycling.Caused by Low Freon Due to Leak on Discharge Relief Valves.Valve Will Be Replaced + (ML20028G609)
- ML20028G610 + (ML20028G610)
- ML20028G611 + (ML20028G611)
- ML20028G612 + (ML20028G612)
- 05000327/LER-1983-001, Forwards LER 83-001/03L-0 + (ML20028G613)
- ML20028G614 + (ML20028G614)
- 05000296/LER-1983-002, Forwards LER 83-002/03L-0 + (ML20028G615)
- ML20028G616 + (ML20028G616)
- ML20028G618 + (ML20028G618)
- 05000327/LER-1983-001-03, /03L-0:on 830113,during Mode 5,pressurizer Safety Valve I-RV-68-565 Not Tested within Setpoint Lift Setting Limits.Caused by Relaxation of Valve Spring Due to Normal Wear.New Valve Installed & Tested + (ML20028G619)
- 05000296/LER-1983-002-03, /03L-0:on 830112,primary Purge Sys Failed to Achieve Required Flow Rate of Greater than 10% of Design. Caused by Filter Internals Clogged W/Sand Dust from Sandblasting.New Filters Installed + (ML20028G621)
- ML20028G622 + (ML20028G622)
- 05000339/LER-1983-016, Forwards LER 83-016/03L-0 + (ML20028G623)
- ML20028G624 + (ML20028G624)
- ML20028G625 + (ML20028G625)
- ML20028G626 + (ML20028G626)
- ML20028G628 + (ML20028G628)
- ML20028G629 + (ML20028G629)
- ML20028G630 + (ML20028G630)
- 05000339/LER-1983-016-03, /03L-0:on 830115 & 16,both Open & Closed Containment Isolation Valves TV-SI-200 & TV-CC-204C,train a Position Indication Lights Found Lit.Caused by Leaking Steam Generator Chemical Feed Line Vent Valve + (ML20028G631)
- ML20028G632 + (ML20028G632)
- ML20028G635 + (ML20028G635)
- ML20028G636 + (ML20028G636)
- ML20028G638 + (ML20028G638)
- ML20028G640 + (ML20028G640)
- ML20028G641 + (ML20028G641)
- ML20028G642 + (ML20028G642)
- ML20028G643 + (ML20028G643)
- ML20028G645 + (ML20028G645)
- ML20028G646 + (ML20028G646)
- ML20028G647 + (ML20028G647)
- 05000338/LER-1983-003, Forwards LER 83-003/03L-0 + (ML20028G649)
- ML20028G650 + (ML20028G650)
- ML20028G652 + (ML20028G652)
- ML20028G653 + (ML20028G653)
- 05000338/LER-1983-003-03, /03L-0:on 830122,during Mode 5,RHR Flow Was Lost for 4 Minutes.Caused by Failure of 15 Kv a Inverter to Ac Vital Bus 1-III,de-energizing Auxiliary Relay for Pressure Channel P-1403.Vital Bus 1-III & RHR Flow Restored + (ML20028G654)
- ML20028G655 + (ML20028G655)
- ML20028G656 + (ML20028G656)
- ML20028G657 + (ML20028G657)
- ML20028G658 + (ML20028G658)