TENMSSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 374o1 1750 Chestnut Street Tower II February 10, 1983 Mr. James P. O'Reilly, Director U.S. Nuclear Regulatory Commission

]

Office'of Inspection and Enforcement a

Region II 101 Marietta Street, Suite 3100

~

Atlanta, Georgia 30303 n

8

Dear Mr. O'Reilly:

en TENNESSEE VALLEY AUTHORITY - BROWNS FERRY NUCLEAR PLANT UNIT 3 - DGCKET NO. 50-296 - FACILITY OPERATING LICENSE DPR REPORTABLE OCCURRENCE REPORT BFRO-50-296/83002 The enclosed report provides details concerning failure of the primary containment purge system to achieve design flow.

This report is submitted in accordance with Browns Ferry unit 3 Technical Specification 6.7.2.b(4).

Very truly yours, TENNESSEE VALLEY AUTHORITY

'h t

. J. Gre n irector of Nuclear Power Enclosure cc (Enclosure):

Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Records Center Institute of Nuclear Power Operations Suite 1500 1100 Circle 75 Parkway Atlanta, Georgia 30339 NRC Inspector, Browns Ferry N

~

f TICI AI,il!I"t 8302170142 830210 8b PDR ADOCK 05000296 S

PDR An Equal Opportunity Empl oyer