- ML20028F278 + (ML20028F278)
- ML20028F279 + (ML20028F279)
- ML20028F280 + (ML20028F280)
- ML20028F282 + (ML20028F282)
- 05000368/LER-1982-033-03, In Mode 6,safety Injection Check Valve LSI-13C Stuck in Open Position When Stroked by Hand.Caused by Protruding Valve Disc Stud Interfering W/Body & Holding Disc in Open Position + (ML20028F284)
- ML20028F285 + (ML20028F285)
- ML20028F287 + (ML20028F287)
- 05000267/LER-1983-001-01, /01T-0:on 830101 & 02,reactor Operated W/O Min Number of Operable Moisture Monitor Channels Required Per Table 4.4.1 of Limiting Conditions for Operation.Caused by Personnel Misinterpretation of Tech Specs + (ML20028F288)
- ML20028F289 + (ML20028F289)
- ML20028F290 + (ML20028F290)
- ML20028F292 + (ML20028F292)
- ML20028F293 + (ML20028F293)
- ML20028F295 + (ML20028F295)
- ML20028F302 + (ML20028F302)
- ML20028F304 + (ML20028F304)
- ML20028F306 + (ML20028F306)
- ML20028F307 + (ML20028F307)
- ML20028F309 + (ML20028F309)
- ML20028F310 + (ML20028F310)
- ML20028F312 + (ML20028F312)
- ML20028F314 + (ML20028F314)
- ML20028F315 + (ML20028F315)
- ML20028F317 + (ML20028F317)
- ML20028F319 + (ML20028F319)
- ML20028F321 + (ML20028F321)
- ML20028F324 + (ML20028F324)
- ML20028F326 + (ML20028F326)
- ML20028F332 + (ML20028F332)
- ML20028F335 + (ML20028F335)
- ML20028F337 + (ML20028F337)
- ML20028F339 + (ML20028F339)
- ML20028F340 + (ML20028F340)
- ML20028F342 + (ML20028F342)
- ML20028F343 + (ML20028F343)
- ML20028F344 + (ML20028F344)
- 05000339/LER-1983-008, Forwards LER 83-008/03L-0 + (ML20028F347)
- ML20028F348 + (ML20028F348)
- 05000339/LER-1983-008-03, /03L-0:on 830107,during Mode 3,individual Rod Position Indication Deviated from Group Demand Position by Greater than 12 Steps While Withdrawing Shutdown Bank B. Caused by Instrument Drift.Rods Recalibr + (ML20028F350)
- ML20028F351 + (ML20028F351)
- ML20028F353 + (ML20028F353)
- ML20028F354 + (ML20028F354)
- 05000324/LER-1982-142, Forwards LER 82-142/03L-0 + (ML20028F355)
- ML20028F356 + (ML20028F356)
- 05000237/LER-1982-058, Forwards LER 82-058/03L-0 + (ML20028F357)
- ML20028F358 + (ML20028F358)
- ML20028F359 + (ML20028F359)
- 05000324/LER-1982-142-03, /03L-0:on 821218,PCIV B32-F058B,located at RIP X-241B,found Closed.Caused by Const Personnel Accidently Bumping Valve &/Or Associated Instrument Piping.Valve Opened & Personnel Counseled + (ML20028F361)
- 05000361/LER-1982-168, Forwards LER 82-168/03L-0.Detailed Event Analysis Submitted + (ML20028F362)
- ML20028F363 + (ML20028F363)
- ML20028F365 + (ML20028F365)
- 05000361/LER-1982-168-03, /03L-0:on 821212,indicated Position for Shutdown Control Element Assembly 12 Went from 148 Inches to 120 Inches Resulting in Reactor Trip.Caused by Failure of Reed Switch.Switch Replaced.No Further Corrective Action Planned + (ML20028F366)