- 05000280/LER-1981-050-03, /03L-0:on 810804,during Routine Walkdown,Oil Discovered Being Slung from Outboard Bearing of Charging Pump A.Caused by Tube Leak in Pump Lube Oil Cooler Which Admitted Water to Lube Oil,Causing Seal Failure + (ML20010F114)
- 05000260/LER-1981-043-01, /01T-0:on 810815,4,160-volt Shutdown Board U-2 Was Made Critical from Cold Condition W/Start Bus Undervoltage Relays Out of Svc for Start Bus 1A.Caused by Personnel Error.Relays Were Reconnected + (ML20010F115)
- 05000324/LER-1981-085-03, /03L-0:on 810808,rod 26-11 Did Not Have RTGB Position Indication at Position 47.Probably Caused by Defective Rod Position Indication Probe Switch.Problem Will Be Corrected During Future Outage + (ML20010F116)
- ML20010F117 + (ML20010F117)
- 05000324/LER-1981-077, Forwards LER 81-077/03L-0 + (ML20010F119)
- ML20010F120 + (ML20010F120)
- 05000280/LER-1981-051-03, /03L-0:on 810804,both Charging Pump Svc Water Pumps 2-SW-P-10A & B Lost Suction & Were Secured W/Unit at 100% Power.Caused by Increased Use of Svc Water by Chillers Causing Loss of Suction Pressure + (ML20010F121)
- AECM-81-320, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/81-24.Corrective Actions:Vendor Documentation Clerk Reinstructed as to Distribution Requirements.No Proprietary Info + (ML20010F122)
- 05000324/LER-1981-077-03, /03L-0:on 810814,rod Overtravel Annunciator Received During Verification of rod-drive Coupling for Rod 18-47.Cause Unknown.Rod Reinserted & Deactivated.Drive Will Be Removed & Inspected During Next Outage + (ML20010F123)
- ML20010F124 + (ML20010F124)
- 05000324/LER-1981-089, Forwards LER 81-089/03L-0 + (ML20010F125)
- ML20010F126 + (ML20010F126)
- ML20010F127 + (ML20010F127)
- PNO-V-81-046, on 810821,during Unloading of Low Level Radwaste Shipment,Metal Bin Appeared to Be Leaking Liquid. Contamination Check Indicated Radioactive Matls.State of Wa Cancelled Burial Permit & Banned Licensee Effective 810831 + (ML20010F128)
- 05000324/LER-1981-088, Forwards LER 81-088/03L-0 + (ML20010F129)
- ML20010F130 + (ML20010F130)
- 05000324/LER-1981-089-03, /03L-0:on 810817,primary Containment Atmospheric Oxygen Analyzer 2-CAC-AT-1263-2,Model F3M3 Found W/Drywell Oxygen Concentration High.Probably Caused by Instrument Drift.Analyzer Recalibr.Analyzers to Be Replaced + (ML20010F131)
- ML20010F132 + (ML20010F132)
- IR 05000416/1981024 + (ML20010F133)
- 05000324/LER-1981-088-03, /03L-0:on 810811,primary Containment Atmospheric Oxygen Analyzer 2-CAC-AT-1263,Model F3M3,was Found Out of Calibr & Could Not Be Recalibr.Caused by Moisture Accumulation in Electromagnetic Unit.Unit Replaced + (ML20010F135)
- PNO-I-81-101A, on 810902,regional Inspectors Conducted re-enactment of Incident Where Exposed Individual Manipulated Collimator Containing Source W/Hand.Further Evaluation of Whole Body & Left Hand Doses to Be Conducted + (ML20010F137)
- PNO-V-81-047A, on 810903,tests Performed on Safety Injection Valves in Discharge of Main Feedwater/Safety Injection Pumps.Caused by Followup to Feedwater Transient Finding That Valves May Have Failed.Investigation Underway + (ML20010F138)
- ML20010F139 + (ML20010F139)
- ML20010F142 + (ML20010F142)
- ML20010F143 + (ML20010F143)
- ML20010F144 + (ML20010F144)
- ML20010F145 + (ML20010F145)
- ML20010F146 + (ML20010F146)
- ML20010F147 + (ML20010F147)
- ML20010F148 + (ML20010F148)
- 05000272/LER-1981-075, Forwards LER 81-075/03L-0.Detailed Event Analysis Encl + (ML20010F149)
- ML20010F150 + (ML20010F150)
- ML20010F151 + (ML20010F151)
- ML20010F152 + (ML20010F152)
- ML20010F153 + (ML20010F153)
- ML20010F154 + (ML20010F154)
- IR 05000329/1981008 + (ML20010F155)
- 05000364/LER-1981-032-03, /03L-0:on 810731,containment Atmosphere Radioactivity Monitoring Sys Was Declared Inoperable Due to Filter Paper Not Advancing.Caused by Filter Paper Spool Plates Slipping.Plates Tightened + (ML20010F157)
- 05000272/LER-1981-075-03, /03L-0:on 810809,containment Fan Coil Unit 13 Declared Inoperable Due to No Svc Water Flow Indication. Caused by Equipment Failure.Flow Transmiter FA-3543Z-1 Sensing Line Blown Clear & Transmitter Recalibr + (ML20010F158)
- ML20010F160 + (ML20010F160)
- AECM-81-318, Final Deficiency Rept PRD-81/08 Re Installation of Standby Svc Water Pump,Initially Reported 810212.Item Reportable Under 10CFR50.55e But Not Under Part 21.Metal Will Be Machined from Outer Edge of Suction Bell on Four Pumps + (ML20010F163)
- ML20010F165 + (ML20010F165)
- 05000364/LER-1981-033-03, /03L-0:on 810801,instrumentation Loop Associated W/Refueling Water Storage Tank Level Transmitter Was Declared Inoperable.Caused by Level Indicator Failing High Due to Moisture in Transmitter Junction Box + (ML20010F166)
- ML20010F167 + (ML20010F167)
- ML20010F169 + (ML20010F169)
- ML20010F170 + (ML20010F170)
- ML20010F171 + (ML20010F171)
- ML20010F172 + (ML20010F172)
- 05000348/LER-1981-054-03, /03L-0:on 810730,instrument Channel N-43 Was Declared Inoperable When High Flux Trip Setpoint Exceeded Acceptance Criteria.Caused by Setpoint Drift.Trip Setpoint Reset + (ML20010F173)
- ML20010F174 + (ML20010F174)
- 05000348/LER-1981-055-03, /03L-0:on 810728,during Review of Monthly Surveillance Schedule,Determined That Surveillance Test FNP-1-STP-227.1B Had Not Been Performed for Apr,May or June. Caused by Error in Scheduling + (ML20010F175)