- IR 05000320/1981013 + (ML20010E113)
- 05000219/LER-1981-041, Forwards LER 81-041/01P-0 + (ML20010E114)
- ML20010E115 + (ML20010E115)
- ML20010E116 + (ML20010E116)
- 05000219/LER-1981-041-01, /01P-0:on 810824,stack Gas Pump a Tripped Causing Stack Gas Low Flow Alarm to Annunciate.Caused by Thermal Overload Due to Pump Binding from Brittle Carbon Vanes.Stack Gas Sample Pump Rebuilt + (ML20010E117)
- ML20010E118 + (ML20010E118)
- 05000237/LER-1981-049, Forwards LER 81-049/01T-0.Detailed Event Analysis Encl + (ML20010E119)
- ML20010E120 + (ML20010E120)
- ML20010E121 + (ML20010E121)
- 05000237/LER-1981-049-01, /01T-0:on 810814,valves 2-203-1A & 2-203-1D Had Closure Time Limits of 2.1-s & 1.7-s,respectively.Caused by Misadjusted Timing Mechanisms on Valves.Valves Adjusted + (ML20010E123)
- 05000255/LER-1981-031, Forwards LER 81-031/03L-0 + (ML20010E124)
- ML20010E125 + (ML20010E125)
- ML20010E126 + (ML20010E126)
- ML20010E127 + (ML20010E127)
- ML20010E128 + (ML20010E128)
- ML20010E129 + (ML20010E129)
- 05000255/LER-1981-031-03, /03L-0:on 810725,LPSI Pump Suction Valves from Sirw Tank & PCS Were Misaligned.Caused by Cl 3.2 Incorrect Identification of Valve Positions.Administrative Controls for Cl Revisions Will Be Changed to Require Proofreading + (ML20010E130)
- 05000155/LER-1981-014, Forwards LER 81-014/03L-0 + (ML20010E131)
- ML20010E133 + (ML20010E133)
- 05000315/LER-1981-030-03, /03L-0:on 810727,pressurizer Pressure Channel NPP-153 Was Indicating Approx 100 Psi Higher than Normal During Unit Heatup.Caused by Pressurizer Pressure Transmitter Calibr Drift.Transmitter Calibr + (ML20010E134)
- 05000155/LER-1981-014-03, /03L-0:on 810728,both Emergency Condenser Radiation Monitors Were Removed from Svc During Repairs to Power Supply Component.Caused by Possibility of Shock & Fire Hazard.Monitors Returned to Svc within 15 Minutes + (ML20010E135)
- ML20010E136 + (ML20010E136)
- ML20010E137 + (ML20010E137)
- 05000315/LER-1981-031-03, /03L-0:on 810807,612-ft Elevation Containment Inner Airlock Door Interlock Was Found Inoperable During Containment Entry.Caused by Broken Cable.Cable Replaced + (ML20010E138)
- ML20010E139 + (ML20010E139)
- ML20010E141 + (ML20010E141)
- ML20010E142 + (ML20010E142)
- 05000315/LER-1981-032-03, /03L-0:on 810727,TDAFP Could Not Meet Discharge Pressure & Flow Requirements Per Tech Specs.Caused by TDAFP Governor Valve Repair During Outage.Linkage Adjustments Were Not Made.Procedures Modified + (ML20010E143)
- ML20010E144 + (ML20010E144)
- IR 05000073/1981003 + (ML20010E145)
- ML20010E146 + (ML20010E146)
- ML20010E148 + (ML20010E148)
- IR 05000344/1981020 + (ML20010E150)
- ML20010E151 + (ML20010E151)
- ML20010E152 + (ML20010E152)
- ML20010E154 + (ML20010E154)
- ML20010E155 + (ML20010E155)
- ML20010E156 + (ML20010E156)
- ML20010E158 + (ML20010E158)
- ML20010E160 + (ML20010E160)
- IR 05000423/1981004 + (ML20010E162)
- ML20010E163 + (ML20010E163)
- ML20010E164 + (ML20010E164)
- IR 05000228/1981002 + (ML20010E166)
- ML20010E167 + (ML20010E167)
- 05000155/LER-1981-016, Forwards LER 81-016/01T-0 + (ML20010E168)
- AECM-81-335, Forwards Addl Info Re Evaluations of Class IE Electrical Equipment,Per NUREG-0588 + (ML20010E170)
- ML20010E171 + (ML20010E171)
- ML20010E172 + (ML20010E172)
- ML20010E173 + (ML20010E173)
- 05000155/LER-1981-016-01, /01T-0:on 810813,discovered That Actions to Mitigate Potential for Pressurization of Reactor Containment from Instrument & Svc Air Sources Not Incorporated Into Plant Procedures + (ML20010E174)