List of results
- 05000298/LER-1981-011-03, /03L-0:on 810528,during Insp of Unexpected Alarm, CS Header Break Detection Instrument Switches Found Piped to Incorrect Lines.Caused by Connection to Wrong Line at Drywell Penetration.Instruments Connected to Proper Lines + (ML20009E620)
- ML20009E621 + (ML20009E621)
- ML20009E622 + (ML20009E622)
- ZS-2019-0114, Restoration Project Final Status Survey Report - Phase 3, A14 FSS Release Record - Survey Unit 10209E + (ML20009E623)
- ML20009E624 + (ML20009E624)
- ML20009E628 + (ML20009E628)
- 05000316/LER-1981-028, Forwards LER 81-028/01T-0.Clarification of Reporting Requirements Per IE Bulletin 80-24 Requested + (ML20009E629)
- ML20009E634 + (ML20009E634)
- 05000334/LER-1981-060, Forwards LER 81-060/03L-0 + (ML20009E635)
- ML20009E638 + (ML20009E638)
- ML20009E639 + (ML20009E639)
- ML20009E640 + (ML20009E640)
- 05000316/LER-1981-028-01, /01T-0:on 810709,1-inch Lower Containment Ventilation Cooling Coil Drain Valve Bonnet Found Leaking. Caused by Loose Valve Bonnet.Bonnet Tightened + (ML20009E642)
- 05000334/LER-1981-060-03, /03L-0:on 810616,during Operations Procedure to Dampen Axial Xenon Oscillations,Delta Flux Outside of Target Band Alarm Was Received When Flux Left High Side of Target. Caused by Xenon Oscillation.Procedures Revised + (ML20009E644)
- IR 05000341/1981009 + (ML20009E645)
- 05000305/LER-1981-023, Forwards LER 81-023/03L-0 + (ML20009E647)
- ML20009E648 + (ML20009E648)
- ML20009E649 + (ML20009E649)
- ML20009E652 + (ML20009E652)
- ML20009E653 + (ML20009E653)
- ML20009E654 + (ML20009E654)
- 05000321/LER-1981-063, Forwards LER 81-063/03L-0 + (ML20009E658)
- ML20009E659 + (ML20009E659)
- ML20009E660 + (ML20009E660)
- ML20009E661 + (ML20009E661)
- 05000305/LER-1981-023-03, /03L-0:on 810621,boric Acid Found Leaking from Instrument Isolation Valve CVC-11188.Caused by Leaking Diaphragm & Corroded Bonnet.Transfer Pump 1A Isolated & Bonnet Assembly Replaced + (ML20009E662)
- ML20009E663 + (ML20009E663)
- ML20009E664 + (ML20009E664)
- 05000289/LER-1981-007, Forwards LER 81-007/99X-0 + (ML20009E665)
- ML20009E666 + (ML20009E666)
- ML20009E667 + (ML20009E667)
- 05000321/LER-1981-063-03, /03L-0:on 810630,high Pressure Core Injection Steamline Switch Found to Acutate High.Caused by Setpoint Drift.Switch Recalibr & Returned to Svc + (ML20009E668)
- ML20009E669 + (ML20009E669)
- ML20009E670 + (ML20009E670)
- 05000302/LER-1981-035, Forwards LER 81-035/03L-0 + (ML20009E671)
- ML20009E672 + (ML20009E672)
- ML20009E676 + (ML20009E676)
- 05000289/LER-1981-007-99, /99X-0:on 810702,pipe Supports Found Located or Oriented Improperly When Installed Per IE Bulletin 79-02 & 79-14 Insp Results.Caused by Inadequate Insp Prior to Operation.Supports Are Being Modified + (ML20009E677)
- 05000302/LER-1981-035-03, /03L-0:on 810616,regulating Rod Groups 6 & 7 Exceeded Overlap Requirements.Caused by Procedural Deficiencies Resulting in Failure to Note Loss of Permissive Logic When Transferring Power Supplies + (ML20009E678)
- ML20009E679 + (ML20009E679)
- 05000302/LER-1981-037, Forwards LER 81-037/03L-0 + (ML20009E681)
- ML20009E682 + (ML20009E682)
- 05000339/LER-1981-051, Forwards LER 81-051/03L-0 + (ML20009E683)
- ML20009E684 + (ML20009E684)
- 05000267/LER-1981-035, Forwards LER 81-035/03L-0.Detailed Event Analysis Also Encl + (ML20009E686)
- ML20009E687 + (ML20009E687)
- 05000302/LER-1981-037-03, /03L-0:on 810617,during Performance of SP-110, Reactor Protection Sys Functional Testing,Delta Flux Module Meter Indication for Channel C Was Less Conservative than Requirement.Caused by Instrument Drift.Generator Recalibr + (ML20009E688)
- 05000302/LER-1981-034, Forwards LER 81-034/03L-0.Detailed Event Analysis Encl + (ML20009E698)
- ML20009E699 + (ML20009E699)
- ML20009E700 + (ML20009E700)
- 05000267/LER-1981-035-03, /03L-0:on 810511,w/plant at 70% Thermal Power During a Diesel Generator Set Surveillance Test,B Engine Tripped & Declutched.Caused by Failed Exhaust Temp Switch. Switch Repaired.Test Completed.Generator Returned to Svc + (ML20009E701)