Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19343C206 + (ML19343C206)
- 05000219/LER-1976-022-03, /03L-0:on 760910,acceptance Criteria in Procedures 629 & 614 for Low & low-low Reactor Level Trip Points Found Less Conservative than Tech Specs.Caused by Faulty Surveillance Test Procedure.Trip Point Settings Calibr + (ML19343C207)
- 05000219/LER-1976-021-03, /03L-0:on 760820,while Performing Pump Operability Test for Containment Spray Sys 1,valve V-21-18 Failed to Open When Auto Start Signal Applied.Caused by Contact Switch Failure Due to Dirty Switch Contacts + (ML19343C208)
- 05000219/LER-1976-020-03, /03L-0:on 760727,while Performing Surveillance on Fire Electromatic Relief Valve switches,1A83B Tripped at 1,100 Psig.Caused by Instrument Repeatability.Trip Point Reset + (ML19343C209)
- ML19343C211 + (ML19343C211)
- ML19343C212 + (ML19343C212)
- 05000219/LER-1976-017-01, /01P-0:on 760701,oxygen Concentration in Torus Reached Indicted Level of 5.4% Which Exceeded Tech Specs Limit.Caused by Erratic Behavior of Torus Oxygen Analyzer Following Calibr + (ML19343C213)
- 05000219/LER-1976-012-03, /03L-0:on 760414,maint Personnel Discovered That Sensing Line to Flow Switch in Standby Gas Treatment Sys I Were Reversed & Switched out-of-calibr.Cause Unknown.Sensing Lines Oriented Properly & Switch Recalibr + (ML19343C214)
- ML19343C215 + (ML19343C215)
- 05000219/LER-1976-010-03, /03L-0:on 760401,during Pump Operability Test for Containment Spray Sys 2,torus Spray Valve V-21-15 Failed to Open.Caused by Misaligned Starter Contacts.Contacts Repositioned & Inspected + (ML19343C216)
- ML19343C217 + (ML19343C217)
- ML19343C218 + (ML19343C218)
- ML19343C219 + (ML19343C219)
- ML19343C220 + (ML19343C220)
- ML19343C221 + (ML19343C221)
- ML19343C222 + (ML19343C222)
- ML19343C223 + (ML19343C223)
- ML19343C224 + (ML19343C224)
- ML19343C225 + (ML19343C225)
- ML19343C226 + (ML19343C226)
- ML19343C227 + (ML19343C227)
- ML19343C228 + (ML19343C228)
- ML19343C229 + (ML19343C229)
- ML19343C230 + (ML19343C230)
- 05000213/LER-1978-007-03, /03L-0:on 780504,pinhole Leak Found in Pumps Discharge Recirculation Orifice Bypass Valve.Caused by Severe Erosion Due to Valve Design.Valve Replaced & Better Design Under Investigation + (ML19343C231)
- ML19343C232 + (ML19343C232)
- 05000213/LER-1978-004-01, /01T-0 Suppl:On 780427-28,significant Gas Generation & Pressure Buildup Found in Annular Poison Cavity in Spent Fuel Racks.Caused by Decomposition in B4C Plates &/Or Decomposition of Binder Matl Used w/B4C Plates + (ML19343C233)
- ML19343C234 + (ML19343C234)
- 05000213/LER-1978-005-03, /03L-0:on 780403,HPIS Pump a Dragged During Manual Operation to Check Coupling Alignment.Caused by Cracked Wear Rings & Impeller Bushing.All Rings & Bushings Replaced.Pump re-assembled,test Run & Found Acceptable + (ML19343C235)
- ML19343C236 + (ML19343C236)
- ML19343C237 + (ML19343C237)
- ML19343C238 + (ML19343C238)
- 05000213/LER-1978-003-03, /03L-0:on 780317,leak Found at Junction of Waste Liquid/Steam Generator Blowdown Line & Svc Water Effluent Blowdown Line.Caused by Interaction of Hot Generator Blowdown & Cold Svc Water.Line Repaired & Pipe Extended + (ML19343C239)
- ML19343C240 + (ML19343C240)
- ML19343C241 + (ML19343C241)
- ML19343C242 + (ML19343C242)
- 05000213/LER-1978-001-01, /01T-0:on 780126,Marathon Terminal Blocks Failed in twenty-second Hour of Scheduled 24-h Screening Type Test to Show Ability to Function in Postulated Containment Environ After Loca.Caused by Current Path + (ML19343C243)
- ML19343C245 + (ML19343C245)
- ML19343C246 + (ML19343C246)
- ML19343C247 + (ML19343C247)
- ML19343C248 + (ML19343C248)
- ML19343C249 + (ML19343C249)
- ML19343C250 + (ML19343C250)
- ML19343C251 + (ML19343C251)
- ML19343C252 + (ML19343C252)
- GO2-19-162, Amendment 65 to Final Safety Analysis Report, Chapter 12, Radiation Protection + (ML19343C253)
- 05000213/LER-1977-009-03, /03L-0:on 770531,overhead Crane Control Malfunctioned,Lifting Spent Fuel Racks Approx 12 & 6 Inches. Caused by Button Stuck in Depressed Position Due to Mechanical Wear of Button Internal Mechanism.Button Replaced + (ML19343C254)
- 05000213/LER-1977-008-03, /03L-0:on 770523,containment Air Recirculation Fan 2 Vibration Exceeded Alarm Setpoints.Caused by Normal Wear. Bearing Replaced + (ML19343C255)
- ML19343C256 + (ML19343C256)
- 05000213/LER-1977-007-03, /03L-0:on 770428,inboard Motor Bearing Temp Increase Caused Charging Pump 1A to Be Shut Down.Caused by Excessive Thrust on Motor Bearing Thrust Plate Due to Axial Misalignment Between Pump & Motor.Bearings Replaced + (ML19343C257)
- 05000213/LER-1977-006-03, /03L-0:on 770426,while Filling & Venting Charging Pump 1A,small Weep Noted on Suction End Mechanical Seal Housing 1A.Caused by Small Leak Path Opened Through Slight Porosity During Decontamination of Housing.Housing Replaced + (ML19343C258)