- 05000133/LER-1980-006-03, /03L-0:on 800926,w/plant Shut Down,Leak Observed in Gate Valve Housing at Screen Wash Pump Discharge 6.Caused by Corrosion & Erosion,Due to Natural end-of-life.Valve Will Be Replaced W/Pratt Monoflange Mk II Butterfly Valve + (ML19338G123)
- 05000259/LER-1980-074, Forwards LER 80-074/03L-0 + (ML19338G124)
- ML19338G125 + (ML19338G125)
- 05000366/LER-1980-137, Forwards LER 80-137/03L-0 + (ML19338G126)
- ML19338G127 + (ML19338G127)
- 05000133/LER-1980-005-03, /03L-0:on 800926,w/plant Shutdown,Water Seepage Observed Through Cracks in Pavement 4 Ft Above 10-inch Line Connecting Screen Wash Pumps in Fossil & Nuclear Units. Caused by Faulty Installation.Broken Section to Be Replaced + (ML19338G128)
- ML19338G129 + (ML19338G129)
- 05000267/LER-1980-055, Forwards LER 80-055/03L-0 + (ML19338G130)
- ML19338G131 + (ML19338G131)
- 05000366/LER-1980-137-03, /03L-0:on 800929,during Plant Shutdown,While Performing HPCI Turbine Exhaust Diaphragm Functional Test & Calibr,Pressure Switch Actuated Contrary to Tech Spec.Caused by Setpoint Drift.Switch Recalibr & Functionally Tested + (ML19338G132)
- 05000267/LER-1980-055-03, /03L-0:on 800918,sampling Requirements of SR Nr 1.1 Were Not Met for Night Shift.Caused by Personnel Oversight.Personnel Have Been Reinstructed as to Procedure Importance + (ML19338G133)
- ML19338G134 + (ML19338G134)
- ML19338G135 + (ML19338G135)
- ML19338G136 + (ML19338G136)
- ML19338G137 + (ML19338G137)
- 05000293/LER-1980-070, Forwards LER 80-070/01T-0 + (ML19338G138)
- ML19338G139 + (ML19338G139)
- ML19338G140 + (ML19338G140)
- 05000293/LER-1980-070-01, /01T-0:on 801010,480 Volt Breaker 52-204 Tripped Twice within 10 Minutes de-energizing 480 Volt Bus B14, Disabling Loop a of Rbccw.Cause Unknown.Breaker Closed,Bus Returned to Svc & Loop a Returned to Normal + (ML19338G141)
- ML19338G142 + (ML19338G142)
- 05000293/LER-1980-073, Forwards LER 80-073/03L-0 + (ML19338G143)
- ML19338G144 + (ML19338G144)
- ML19338G145 + (ML19338G145)
- ML19338G146 + (ML19338G146)
- 05000348/LER-1980-057-03, /03L-0:on 800922,during Startup,Rhr Sys Was Removed from Svc & Isolated from RCS at 250 F.Caused by Operator Error.Tech Specs Changed to Clarify Svc Procedure + (ML19338G147)
- 05000293/LER-1980-073-03, /03L-0:on 800917,mgt Review of Records Revealed That Monthly Surveillance Test SP74-41,visual Insp of Energy Piping Outside Containment,Was Not Performed within Required Interval.Caused by Scheduling Error + (ML19338G148)
- ML19338G149 + (ML19338G149)
- 05000259/LER-1980-074-03, /03L-0:on 800924,during Normal Operation,Seismic Monitor SMA2 Found Inoperable.Caused by Failed Printed Wiring Board 100935.Assembly Repaired,Tested & Returned to Svc.Failure Considered Random.No Further Action Planned + (ML19338G151)
- 05000267/LER-1980-054, Forwards LER 80-054/03L-0 + (ML19338G152)
- ML19338G153 + (ML19338G153)
- ML19338G155 + (ML19338G155)
- 05000334/LER-1980-075-01, /01T-0:on 801008,determined That Overstress Condition Exists on Reactor Coolant Fill Header from High Head Charging Pumps.Cause Unknown.Necessary Mods Made Prior to Start Up + (ML19338G156)
- 05000313/LER-1980-037, Forwards LER 80-037/03L-0 + (ML19338G157)
- ML19338G158 + (ML19338G158)
- 05000213/LER-1980-014-03, /03L-0:on 800926,during Surveillance Testing of Diesel Fire Pump,Pump Discharge Pressure at 2500 RPM Found Below Tech Spec Limit.Caused by Low Operating RPM of Diesel Motor.Adjustments Made to Increase Motor RPM + (ML19338G159)
- 05000267/LER-1980-053, Forwards LER 80-053/03L-0 + (ML19338G160)
- ML19338G161 + (ML19338G161)
- 05000213/LER-1980-015-03, /03L-0:on 801020,while Boiling Down Aerated Drains Tank Waste Evaporator in Preparation for Drumming,Level Indication Was Lost.Caused by Failed Gasket on Discharge Piping of Reboiler Pump.Gasket Replaced + (ML19338G162)
- ML19338G163 + (ML19338G163)
- 05000302/LER-1980-040, Forwards LER 80-040/04L-1 + (ML19338G164)
- ML19338G165 + (ML19338G165)
- 05000313/LER-1980-035-99, /99X-0:on 800916,during Investigation of Svc Water Condition,Flow Check & Cooling Coil Indicated Southwest Side of Coolers VCC2C & D Were Partially Restricted.Caused by Buildup of Asian Clams.Engineering Evaluation Is Contin + (ML19338G166)
- ML19338G168 + (ML19338G168)
- 05000325/LER-1980-080, Forwards LER 80-080/03L-0 + (ML19338G169)
- ML19338G170 + (ML19338G170)
- 05000325/LER-1980-080-03, /03L-0:on 800923,low Level Switch 1-B21-LIS-N031A-2 Failed to Actuate.Caused by Sticking Switch Actuator.Switch Actuator Was Cleaned + (ML19338G172)