- ML19290E897 + (ML19290E897)
- ML19290E898 + (ML19290E898)
- 05000304/LER-1980-004, Forwards LER 80-004/03L-0 + (ML19290E900)
- ML19290E902 + (ML19290E902)
- ML19290E903 + (ML19290E903)
- 05000304/LER-1980-004-03, /03L-0:on 800128,during Normal Operation,Maint Personnel Found Steam/Generator Level Transmitter 2LT-538 Had Shifted High by 3.9%.Caused by Transmitter Drift. Transmitter Recalibr + (ML19290E904)
- ML19290E906 + (ML19290E906)
- ML19290E907 + (ML19290E907)
- ML19290E908 + (ML19290E908)
- ML19290E909 + (ML19290E909)
- 05000304/LER-1980-006, Forwards LER 80-006/03L-0 + (ML19290E910)
- ML19290E912 + (ML19290E912)
- 05000304/LER-1980-006-03, /03L-0:on 800202,during Normal Operation, Containment Vent Particulate Rad Monitor 2 RE-0011 Would Not Respond to Check Source Nor Manual Bugging.Apparently Caused by Detector Tube & Hvps Natural End of Life + (ML19290E913)
- ML19290E915 + (ML19290E915)
- ML19290E916 + (ML19290E916)
- 05000344/LER-1980-003, Forwards LER 80-003/03L-0 + (ML19290E917)
- 05000344/LER-1980-003-03, /03L-0:on 800219,functional Check on Reactor Protection Sys Instrumentation Identified Pressurizer Pressure Transmitter PT-457 Setpoints Exceeding Tech Specs. Caused by Instrument Drift.Transmitter Recalibr + (ML19290E919)
- ML19290E920 + (ML19290E920)
- ML19290E921 + (ML19290E921)
- ML19290E922 + (ML19290E922)
- ML19290E923 + (ML19290E923)
- 05000333/LER-1980-020, Advises That Date on Transmittal Ltr for LER 80-020/04L-0 Should Be 800305,instead of 800205 + (ML19290E924)
- ML19290E925 + (ML19290E925)
- ML19290E926 + (ML19290E926)
- ML19290E927 + (ML19290E927)
- ML19290E928 + (ML19290E928)
- ML19290E930 + (ML19290E930)
- ML19290E931 + (ML19290E931)
- ML19290E932 + (ML19290E932)
- ML19290E934 + (ML19290E934)
- ML19290E935 + (ML19290E935)
- ML19290E936 + (ML19290E936)
- ML19290E937 + (ML19290E937)
- ML19290E940 + (ML19290E940)
- ML19290E944 + (ML19290E944)
- ML19290E945 + (ML19290E945)
- ML19290E946 + (ML19290E946)
- ML19290E947 + (ML19290E947)
- ML19290E948 + (ML19290E948)
- 05000338/LER-1980-025, Forwards LER 80-025/03L-0 + (ML19290E950)
- ML19290E951 + (ML19290E951)
- ML19290E952 + (ML19290E952)
- 05000338/LER-1980-025-03, /03L-0:on 800215,channel III Steamline Pressure Protection Bistable for P2 Greater than P1 Safety Injection Initiation Tripped at Unacceptable Setpoint.Caused by Setpoint Drift in Signal Comparator Card Circuitry + (ML19290E953)
- ML19290E957 + (ML19290E957)
- NL-19-1248, Revise Technical Specification Requirements During Handling Irradiated Fuel and Core Alterations - TSTF-51, SNC Response to NRC Request for Additional Information + (ML19290E958)
- ML19290E961 + (ML19290E961)
- ML19290E962 + (ML19290E962)
- ML19290E963 + (ML19290E963)
- 05000254/LER-1980-004, Forwards LER 80-004/03L-0 + (ML19290E964)
- ML19290E965 + (ML19290E965)
- ML19290E966 + (ML19290E966)