- ML19270G364 + (ML19270G364)
- 05000321/LER-1979-033, Fowards LER 79-033/01T-0 + (ML19270G365)
- ML19270G366 + (ML19270G366)
- 05000321/LER-1979-033-01, /01T-0 on 790518:RHR Return Valves E11-F015B & E11-F017B & RHR Pump Suction Valves Leaked During Local Leak Rate Testing.Cause Unknown.Corrective Maint Will Be Performed to Allow Satisfactory Leakage Rate + (ML19270G367)
- 05000304/LER-1979-029, Forwards LER 79-029/03L-0 + (ML19270G368)
- 05000366/LER-1979-034, Forwards LER 79-034/01T-0 + (ML19270G370)
- ML19270G371 + (ML19270G371)
- 05000304/LER-1979-029-03, /03L-0 on 790423:during Change of Startup Batteries on 2C CS Pump,Spray Sys Was Inadvertently Rendered Inoperable W/O Performing Required Surveillance.Caused by Personnel Error in Operating multi-position Switch + (ML19270G372)
- 05000366/LER-1979-034-01, /01T-0 on 790514:instruments in Remote Shutdown Panel H21-P173 & Heating,Ventilation & Air Conditioning Panels H11-P654 & H11-P657 Did Not Meet Seismic Requirements.Caused by Installation Error.Proper Instruents + (ML19270G373)
- ML19270G374 + (ML19270G374)
- 05000366/LER-1979-035, Forwards LER 79-035/03L-0 + (ML19270G375)
- ML19270G376 + (ML19270G376)
- 05000366/LER-1979-035-03, /03L-0 on 790515:procedure HPN-2-3195,weekly Breaker Alignment Checks, Was Performed One Day Late. Caused by Late Issuance of Assignment Sheets.Surveillance Engineer Made Aware of Importance of Prompt Sheet Issuance + (ML19270G377)
- ML19270G379 + (ML19270G379)
- 05000366/LER-1979-036, Forwards LER 79-036/01T-0 + (ML19270G380)
- ML19270G381 + (ML19270G381)
- 05000366/LER-1979-036-01, /01T-0 on 790516:sprinkler Hanger Mods Indicated Seismic Design Deficiency for Cable Spreading Room Designs.Proper Analysis & Mods Have Begun + (ML19270G383)
- 05000266/LER-1979-009, Forwards LER 79-009/01T-0 + (ML19270G384)
- ML19270G385 + (ML19270G385)
- 05000266/LER-1979-009-01, /01T-0 on 790510:during Hydrostatic Test of Fire Water Sys,Compression Fitting Failed.Caused by Broken Flange.Flange Replaced + (ML19270G386)
- ML19270G387 + (ML19270G387)
- 05000266/LER-1979-008, Forwards LER 79-008/01T-0 + (ML19270G388)
- ML19270G389 + (ML19270G389)
- ML19270G390 + (ML19270G390)
- 05000266/LER-1979-008-01, /01T-0 on 790502:remote Possibility Exists for Simultaneous Safety Injection in Both Units,Which Could Result in Emergency Diesel Overloading.Pressurizer Logic & Power Supplies Changed + (ML19270G391)
- ML19270G392 + (ML19270G392)
- 05000409/LER-1979-008, Forwards LER 79-008/03L-0 + (ML19270G393)
- 05000409/LER-1979-008-03, /03L-0 on 790429:during Periodic Type C Leakage Rate Testing,Containment Isolation Did Not Meet Tech Spec Criteria.Caused by Damper Disc Shaft Packing.Replaced W/Chevron Type Asbestos Composition Shaft Packing + (ML19270G395)
- ML19270G396 + (ML19270G396)
- ML19270G397 + (ML19270G397)
- ML19270G398 + (ML19270G398)
- ML19270G399 + (ML19270G399)
- ML19270G400 + (ML19270G400)
- ML19270G401 + (ML19270G401)
- ML19270G402 + (ML19270G402)
- 05000304/LER-1979-031, Forwards LER 79-031/03L-0 + (ML19270G403)
- ML19270G405 + (ML19270G405)
- ML19270G406 + (ML19270G406)
- 05000304/LER-1979-031-03, /03L-0 on 790417:three Inoperable Snubbers Were Found.Caused by Hydraulic Fluid Loss in Two & Physical Disconnection at Piston Rod End in Third.Periodic Insp Changed from Yearly to Six Months + (ML19270G407)
- ML19270G408 + (ML19270G408)
- 05000318/LER-1979-017-03, /03L-0 on 790520:during Surveillance Testing, Diesel Generator 21 Failed to Start Upon Actuation of Remote Start Switch.Caused by Normally de-energized Low Speed Relay Being Energized During Initial Test + (ML19270G409)
- ML19270G410 + (ML19270G410)
- 05000318/LER-1979-017, Forwards LER 79-017/03L-0 + (ML19270G411)
- ML19270G412 + (ML19270G412)
- ML19270G413 + (ML19270G413)
- 05000295/LER-1979-032, Forwards LER 79-032/03L-0 + (ML19270G414)
- ML19270G416 + (ML19270G416)
- ML19270G417 + (ML19270G417)
- 05000295/LER-1979-032-03, /03L-0 on 790420:blower Tripped on Containment Vent Particulate Monitor,Resulting in Low Flow.Caused by Thermal Overload Due to Dust Blocking Pump Vent.Vent Cleaned & Monitor Tested & Returned to Svc + (ML19270G418)
- ML19270G419 + (ML19270G419)
- ML19270G420 + (ML19270G420)