LONG ISLAND LIGHTING COM PANY
(
M w[ L C O,f =
SHOREHAM NUCLEAR POWER STATION af.ugf,
~.I P.O. DOX 618, NORTH COUNTRY ROAD e WADING RIVER, N.Y.11792 a
May 23, 1979 SNRC-392 Mr. Harold R. Denton Division of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 SHOREHAM NUCLEAR POWER STATION - UNIT 1 DOCKET No. 50-322
Dear Mr. Denton:
This letter serves to inform you that the Long Island Lighting Company has invoked Ccde Case 1614 to ASME Section III which states that spray nozzles and spray nozzle attachment welds, if used, need not be hydrostatically tested including class 1, 2 and 3 piping systems which are spray systems.
This change has been reviewed and approved by LILCO, by our engineering and installation agents and has been reviewed and will be approved by the independent code inspection agency, Hartford Steam Boiler Company.
This change will be incorporated into the appropriate design specifications and installation documentation.
Very,[trulyyours, l
)
- 7. n y,_ ' c%vw J. P. Novarro Project Manager v
Shoreham Nuclear Power Station JJM/j k cc:
Mr. Boyce Grier Director Office of Inspection and Enforcement, Region 1 U. S. Nuclear Regulatory Commission 631 Park Avenue 2275
- ,41 King of Prussia, PA 19406 800s S6 80C060985~
$y*
.c.. m
/