- 05000325/LER-1979-022, Forwards LER 79-022/03L-0 + (ML19207B313)
- ML19207B314 + (ML19207B314)
- ML19207B315 + (ML19207B315)
- 05000325/LER-1979-022-03, /03L-0 on 790723:linear Heat Generation Rate Found to Be 0.29 Kw/Ft Above Limit During Daily Core Parameter Check After Reaching 99% Power.Caused by Faulty Computer Reading.After Evaluation 1-3% Power Derate Imposed + (ML19207B316)
- 05000325/LER-1979-049, Forwards LER 79-049/03L-0 + (ML19207B318)
- ML19207B319 + (ML19207B319)
- ML19207B320 + (ML19207B320)
- 05000321/LER-1979-057-03, /03L-0 on 790802:coil for Relay A71-k25 in Panel H11-p623 Failed to Energize While Performing Reactor Water Cleanup Auto Isolation.Caused by burned-out Coil. Relay Replaced & Retested + (ML19207B322)
- 05000325/LER-1979-049-03, /03L-0 on 790724:drywell 0-2 Monitor Air Dryer Showed -1259 Reading During Normal Operation After Routine Preventive Maint.Caused by Ice Buildup on Chiller Coils Resulting in Reduced Sample Flow + (ML19207B323)
- 05000338/LER-1979-085, Forwards LER 79-085/03L-0 + (ML19207B324)
- ML19207B325 + (ML19207B325)
- 05000338/LER-1979-085-03, /03L-0 on 790715:following Power Reduction Caused by Secondary Plant Problems,Quadrant Power Tilt Alarm Was Observed.Possibly Caused by Dropped Rodlets.Tilts Under Review + (ML19207B326)
- ML19207B327 + (ML19207B327)
- ML19207B328 + (ML19207B328)
- ML19207B330 + (ML19207B330)
- ML19207B331 + (ML19207B331)
- ML19207B332 + (ML19207B332)
- ML19207B333 + (ML19207B333)
- ML19207B334 + (ML19207B334)
- ML19207B335 + (ML19207B335)
- 05000324/LER-1979-063, Forwards LER 79-063/03L-0 + (ML19207B336)
- ML19207B337 + (ML19207B337)
- ML19207B338 + (ML19207B338)
- ML19207B340 + (ML19207B340)
- 05000324/LER-1979-063-03, /03L-0 on 790723:during Normal Plant Operation, Technician Working on Fire Protection Mod Discovered Line Drain Valve W/Excessive Leakage.Caused by Check Valve in Drain Line w/off-centered Disk + (ML19207B341)
- ML19207B342 + (ML19207B342)
- ML19207B343 + (ML19207B343)
- ML19207B344 + (ML19207B344)
- 05000321/LER-1979-059, Forwards LER 79-059/03L-0 + (ML19207B345)
- ML19207B346 + (ML19207B346)
- ML19207B347 + (ML19207B347)
- 05000321/LER-1979-059-03, /03L-0 on 790804:while Performing Surveillance Procedure During Shutdown Mode,Switch Failed to Operate at Proper Setpoint.Caused by Foreign Particles on Switch Mechanism.Switch Cleaned & Calibr + (ML19207B349)
- ML19207B350 + (ML19207B350)
- ML19207B351 + (ML19207B351)
- ML19207B352 + (ML19207B352)
- ML19207B353 + (ML19207B353)
- ML19207B354 + (ML19207B354)
- ML19207B355 + (ML19207B355)
- 05000321/LER-1979-060, Forwards LER 79-060/03L-0 + (ML19207B356)
- ML19207B357 + (ML19207B357)
- ML19207B358 + (ML19207B358)
- 05000338/LER-1979-093-03, /03L-0 on 790726:during Mode 1 Operations,Fire Door S54-11 Between Unit 2 Emergency Switchgear Room & Turbine Bldg Found Nonfunctional.Caused by Temporary Cooling Water Hoses Preventing Closure.Hoses Removed + (ML19207B359)
- 05000321/LER-1979-060-03, /03L-0 on 790805:while Performing Normal Surveillance,Auxiliary Relay Failed to Actuate.Caused by Open Relay Coil.Relay Replaced & Functional Test Completed Sucessfully + (ML19207B360)
- 05000338/LER-1979-095-03, /03L-0 on 790727:during Rapid Power Reduction & Subsequent Increase in Power,Oxide Flux Difference Deviated More than 5% from Target for 104 Minutes.Caused by Power Reduction.Power & Control Rods Manipulated by Operator + (ML19207B361)
- ML19207B362 + (ML19207B362)
- ML19207B363 + (ML19207B363)
- ML19207B365 + (ML19207B365)
- ML19207B366 + (ML19207B366)
- ML19207B367 + (ML19207B367)
- 05000263/LER-1979-016, Forwards LER 79-016/03L-0 + (ML19207B368)
- ML19207B369 + (ML19207B369)