BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION In the Matter of Docket Nos. 50-277 PHILADELPHIA ELECTRIC COMPANr 50-278 APPLICATION FOR AMENDMENT OF FACILITY OPERATING LICENSES DPR-44 6 DPR-56 Edward G.
Bauer, Jr.
Eugene J.
Bradley 2301 Market Street Philadelphia, Pennsylvania 19101 Attorneys for Philadelphia Electric Company r, c.
n"n s
7908240
()
BEFOPE THE UNITED STATES NUCLEAR REGULATORY COMMISSION In the Matter of Docket Nos. 50-277 PHILADELPHIA ELECTRIC COMPANY 50-278 APPLICATION FOR AMENDMENT OF FACILITY OPERATING LICENSES DPR-44 6 DPR-56 Philadelphia Electric Company, Licensee under Facility Operating Licenses DPR-44 and DPR-56 for Peach Bottom Atomic Power Station Unit Nos. 2 and 3 respectively, hereby requests that the Technical Specifications incorporated in Appendix A of the Operating Licenses be amended as is indicated by the changes described below.
Change I - Engineering - Health Physics Qualifications In response to a request from the Nuclear Pegulatory Commission, Philadelphia Electric Company, in May of 1979,_
')
J L
t-h
committed to meeting the requirements of Regulatory Guide 1.8, September, 1975 regarding the qualification of the Engineer -
Acalth Physics.
It was agreed that a license amendment request, incorporating these requirements ir.to the Technical Specification, would be submitted.
Therefore, Philadelphia Electric Company hereby requests that the Technical Specifications incorporated in Appendix A to the Facility Operating Licenses be amended by revising section 6.3.1 as indicated by a vertical bar in the margin of attached page 246.
The proposed revision is consistent with section 6. 3.1, page 6-5 of the Standard Technical Specifications for General Electric Boiling Water Reactors.
Chance II - Administrative and Typographical changes Philadelphia Electric Company requests a correction of a typographical error as indicated by a vertical bar in the margin of page 180 in Table 3.7.1 of Appendix A as follows: change the identified isolation group for the Oxygen Analyzer System from 2D to 3.
These valves are actuated by group 3 isolation signals as described in section 7. 3 of the Final Safety Analysis Report.
The valves in group 2D are isolated by high drywell pressure and reactor low water level conditions.
Group 3 valves are isolated by reactor building ventilation exhaust high radiation, and refuel floor ventilation exhaust high radiation in addition to the above conditions. q -- n i
O
Additionally, Philadelphia Electric Company requests a revision to section 6.5.1.2, composition of the Plant Operation Feview Committee, to reflect changes in the plant organization as indicated by a vertical bar in the margin of attached page 246.
Since these amendment requests are administrative in nature, pursuant to 10 CFR 170.22, " Schedule of Fees for Facility License Ame ndme nt", Philadelphia Electric Company proposes that this Application for Amendment be considered a Class II amendment for Unit 2 and a Class I amendment for Unit 3.
The Plant Operation Review Committee and the Operation and Safety Review Committee have reviewed the proposed changes to the Technical Specifications and have concluded that they do not involve an unreviewed safety question or a significant hazard consideration, and will not endanger the health and safety of the public.
Respectfully submitted, PIIILADELPIIIA ELECTRIC COMPANY
[
/
q'
- (
/
Vice~ President // _,
q 4
)
dOMMONWEALTIl OF PENNSYLVANIA ss.
COUNTY OF PilILADELPHIA S.
L.
Daltroff, being first duly sworn, deposes and says:
That he is Vice President of Philadelphia Electric Company, the Applicant herein; that he has read the foregoing Application for Amendment of Facility Operating Licenses and knows the contents thereof; and that the statements and matters set forth therein are true and correct to the oest of his knowledge, information and belief.
f, A
~.,
Subscribed and sworn to fk before me this MO ' day of e
/
A02_h
_ev ry Pemuy CUL 9Gli H GOY.~
,,,,, ; c, F ', c
, t.
gq g
- (; [ v {.,
- ' t. )
l
~
e{ ~.
h
CERTIFICATE OF SERVICE I certify that service of the foregoing Application was made upon the Board of Supervisors, Peach Bottom Township, York County, Pennsylvania, by mailing a copy thereof, via first-class mail, to Albert R.
Steele, Chairman of the Board of Supervisors, R.
D.
No.
1, Delta, Pennsylvania 17314; upon the Board of Supervisors, Fulton Township, Lancaster County, Pennsylvania, by mailing a copy thereof, via first-class mail, to George K.
Brinton, Chairman of the Board of Supervisors, Peach Bottom, Pennsylvania 17563; and upon the Eoard of Supervisors, Drumore Township, Lancaster County, Pennsylvania, by mailing a copy thereof, via first-class mail, to Wilmer P. Bolton, Chairman of the Board of Supervisors, R.
D.
No.
1, Holtwood, Pennsylvania 17532; all this 21st day of
- August, 1979.
5-Nw dgene /. Bradley [
Attordey for Philadelphia Electric company 9--
is J
+
PBAPS 6.3 Facility Staff Oualifications 6.3.1 Each member of the facility staff shall meet or exceed the minimum qualificationu of ANSI N18.1-1971 for comparable positions, except for the Engineer-liealth Physics who shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975.
6.4 Training 6.4.1 A retraining and replacement trainlag program for tne f acility staf f shall be maintained under the direction of th. Station Superintendent and shall meet the requirements of. Section 5.5 of ANSI N18.1-1971 and 10 CFR 55, Appendix A.
6.4.2 A training program for the Fire Brigade shall be conouctec such that Fire Brigade members complete an Instruction program within a two year period.
Regularly planned meetings will be held every 3 months.
- 6. 5 Review and Audit 6.5.1 Plant operation Review Committee (PORC)
Function 6.5.1.1 The Plant Operation Review Committee shall f unction to advise the Station Superintendent on all matters related to nuclear safety.
composition
- 6. 5.1. 2 The Plant Operation Review Committee shall be composed of the:
Station Superintendent-Chairman Station Assistant Superintendent Engineer - Technical Engineer - Maintenance Engineer - Operations Engineer - Results Engineer - Reactor Engineer - Instrument 6 Control Engineer - IIealth Physics Engineer - Chemistry Shift Superintendent Alternates
- 6. 5.1. 3 Alternate members shall be appointed in writing by the PORC Chairman to serve on a temporary basis; however, no more than two alternates shall participate in PORC activities at any one time.
q -,
., 9 Amendment No.
R, 39
-236-
4 9
P TAEL:. 3.7.1 (Cont'd.)
PF I:: AEY CC NT TINME'J r ISCL AT IC. VALVES N2rner ot Power
' *a x.num Action on
';p 9 r a t e t i Valves Operatin')
Normal Initiatiry Group Valve Identification inboarl. Outboard Time (sec. )
Position liign a l t;A Feedwater check valves 2*
2*
!!A O
Process NA Control rod hydraulic return 1*
1*
NA 0
Process check valves T
3 Oxygen Analyzer Syste:n 14 I4A o
- c g
C i
NA Stan iby liquid control s ys t e:n 1*
1*
NA C
Process g
2B PHRb shutdown cooling suction 1
1 32 C
SC I N isolation valves
-C 2 '3 hiiES shutdown cooling 1
24 C
.;C 9#**""
injection isolation vtives 8
23 RiiES heactor Vessel rirea d Seray 1
1 30 C
SC isolation valves 2C Feedwater Flush Valves 2
50 C
SC 4
If PC hi steam line isolation 1
20 0
';C
~
valves S
FCICS steam line isolation 1
1 15 O
GC y
cr valves J
2A Peactor water cleanup system 1
1 30 0
GC isolation valves rQ 2A Reactor water cleanup systen 1
20 0
GC r")
return isolation valt:-
- valvo em c o.o r - n r t cu.
,