- ML18139A527 + (ML18139A527)
- 05000281/LER-1980-017-03, /03L-0:on 800820,during Unit 2 Startup at 18% Power,Control Room Surveillance Revealed Zero Reading from Main Steam Flow Transmitter.Caused by Partially Closed Equalizing Valve.Bistables Tripped & Valve Closed + (ML18139A528)
- 05000281/LER-1980-019-03, /03L-0:on 800822,during Operation Trip Valve TV- SS-206B Would Not Stay Closed When Actuated from Control Room.Caused by Misadjusted Limit Switch.Valve Isolated & Position Limit Switch Readjusted + (ML18139A529)
- 05000281/LER-1980-020-03, /03L-0:on 800822 After Boric Acid Batching,Chemist Reported Concentration Above Tech Spec Requirements.Caused by Transfer of Batch Tank to Inservice Bast.Manual Shutdown Initiated & Boric Acid Diluted to Tech Spec Limits + (ML18139A530)
- ML18139A531 + (ML18139A531)
- ML18139A533 + (ML18139A533)
- ML18139A534 + (ML18139A534)
- ML18139A535 + (ML18139A535)
- IR 05000281/1980024 + (ML18139A536)
- ML18139A537 + (ML18139A537)
- ML18139A539 + (ML18139A539)
- ML18139A540 + (ML18139A540)
- ML18139A541 + (ML18139A541)
- IR 05000280/1980020 + (ML18139A542)
- ML18139A543 + (ML18139A543)
- ML18139A544 + (ML18139A544)
- ML18139A545 + (ML18139A545)
- ML18139A546 + (ML18139A546)
- ML18139A547 + (ML18139A547)
- ML18139A548 + (ML18139A548)
- 05000281/LER-1980-022-03, /03L-0:on 800826,w/unit Operating at Steady State, Channel III Flow Computer,For Steam Generator Steam Flow Fc 2474,failed.Caused by Loose Printed Circuit Board & Cold Solder Joint on Filter Capacitor.Board & Capacitor Repai + (ML18139A549)
- 05000281/LER-1980-021-03, /03L-0:on 800826,while Attempting to Pressurize Accumulator B Using Normal Nitrogen Supply,Pressure Fell Below Allowable Limits.Caused by Leak & Low Pressure in Nitrogen Fill Header.Added Pressure to Sys & Repaired Leak + (ML18139A550)
- ML18139A551 + (ML18139A551)
- ML18139A553 + (ML18139A553)
- 05000280/LER-1980-024-03, /03L-0:on 800828,w/unit in Intermediate Shutdown, Inside Trip Valve TV-SS-200A Would Not Close & Remain Closed When Control Switch Was Released.Caused by Failure of Close Limit Switch.Limit Switch Replaced + (ML18139A555)
- ML18139A556 + (ML18139A556)
- ML18139A557 + (ML18139A557)
- ML18139A558 + (ML18139A558)
- ML18139A559 + (ML18139A559)
- IR 05000281/1980030 + (ML18139A561)
- ML18139A562 + (ML18139A562)
- ML18139A563 + (ML18139A563)
- ML18139A564 + (ML18139A564)
- ML18139A565 + (ML18139A565)
- ML18139A566 + (ML18139A566)
- 05000280/LER-1980-061, Forwards LER 80-061/03L-0 + (ML18139A567)
- ML18139A568 + (ML18139A568)
- 05000280/LER-1980-061-03, /03L-0:on 800904,release valve,HCV-LW-104A,was Not Closed as Required & 3% of a Liquid Waste Test Tank Was Released Before Release Rate Had Been Determined.Caused by Operator Error + (ML18139A569)
- ML18139A570 + (ML18139A570)
- 05000280/LER-1980-066, Forwards LER 80-066/03L-0 + (ML18139A571)
- ML18139A572 + (ML18139A572)
- 05000280/LER-1980-066-03, /03L-0:on 800902,during Monthly Operational Test of Emergency Diesel Generator 1,base Tank Level Dropped to 160 Gallons W/O Being Replenished Automatically from Day Tank.Caused by Stuck Base Tank Control Switch + (ML18139A573)
- ML18139A574 + (ML18139A574)
- IR 05000280/1980027 + (ML18139A576)
- ML18139A578 + (ML18139A578)
- PNO-II-80-141, on 800814,unit Achieved Criticality Following Extended Outage for Steam Generator Replacement.Reactor Will Remain at Low Power for 24-h to Conduct Physics Testing.No Further Action Anticipated + (ML18139A580)
- ML18139A581 + (ML18139A581)
- ML18139A583 + (ML18139A583)
- 05000280/LER-1980-053, Forwards LER 80-053/03L-0 + (ML18139A584)
- ML18139A585 + (ML18139A585)
- 05000280/LER-1980-053-03, /03L-0:on 800909,recirculation Valve 1-RS-6 for Outside Recirculation Spray Pump B Was Found Open.Cause Undetermined + (ML18139A586)