- 05000311/LER-1988-006-02, :on 880421,reactor Trip Occurred.Caused by Maint Technician Not Using Proper Procedure When Repairing Leak on Low Pressure Side of Reactor Coolant Loop 23 Flow Channel II Transmitter.Event Reviewed + (ML18093A831)
- ML18093A833 + (ML18093A833)
- ML18093A834 + (ML18093A834)
- ML18093A835 + (ML18093A835)
- ML18093A836 + (ML18093A836)
- ML18093A837 + (ML18093A837)
- ML18093A839 + (ML18093A839)
- 05000272/LER-1988-001, :on 880211,improper Anchoring of Three Diesel Generator Day Tanks to Supporting Steel Beam Foundation Identified.Caused by Inadequate Design & Design Review. Tanks Weld Anchored to Steel Beam Foundation + (ML18093A840)
- 05000272/LER-1988-018, :on 871209,personnel Determined That Lead/Lag & Derivative Amplifiers in Process & Protection Control Sys Incorrectly Calibr.Caused by Procedural Inadequacy. Procedures Revised + (ML18093A841)
- 05000311/LER-1988-008-02, :on 880426,discovered That Valve 2FP147 Not Surveilled.Caused by Personnel Error.Procedure Revised to Address Requirement to Surveill the 2FP147 Valve & 2FP148 Check Valve at Same Time + (ML18093A842)
- ML18093A845 + (ML18093A845)
- IR 05000272/1988011 + (ML18093A850)
- ML18093A855 + (ML18093A855)
- 05000311/LER-1988-007-02, :on 880422,reactor Trip Occurred Due to Turbine Trip as Result of Steam Generator hi-hi Level.Caused by electro-hydraulic Control (EHC) Equipment Problems.Ehc Rate Amplifier Card Replaced & Successfully Tested + (ML18093A857)
- ML18093A858 + (ML18093A858)
- ML18093A859 + (ML18093A859)
- ML18093A860 + (ML18093A860)
- ML18093A861 + (ML18093A861)
- 05000272/LER-1988-010-01, :on 880519,discovered That Diesel Generator Area Cardox Fire Suppression Sys PE Relay May Not Be Class 1E Seismically Qualified.Caused by Inadequate Design. Procedure Mods Made Re Resetting Relay + (ML18093A863)
- ML18093A864 + (ML18093A864)
- 05000311/LER-1988-009-02, :on 880513,reactor Trip Occurred.Caused by Control Rod 1D3 Drop Resulting in Negative Rate Trip.Testing for Probable Causes of Control Rod Drop Completed + (ML18093A868)
- ML18093A869 + (ML18093A869)
- ML18093A870 + (ML18093A870)
- ML18093A874 + (ML18093A874)
- 05000311/LER-1988-010-02, :on 880509,identified That for 37 Electrical Circuits Penetrating Containment,Backup Overcurrent Protection Device Would Not Operate.Caused by Inadequate Design Review.Detailed Calculation Prepared + (ML18093A875)
- ML18093A876 + (ML18093A876)
- ML18093A877 + (ML18093A877)
- ML18093A878 + (ML18093A878)
- ML18093A879 + (ML18093A879)
- ML18093A881 + (ML18093A881)
- ML18093A883 + (ML18093A883)
- ML18093A884 + (ML18093A884)
- ML18093A885 + (ML18093A885)
- ML18093A890 + (ML18093A890)
- ML18093A891 + (ML18093A891)
- ML18093A893 + (ML18093A893)
- ML18093A894 + (ML18093A894)
- ML18093A895 + (ML18093A895)
- ML18093A897 + (ML18093A897)
- ML18093A899 + (ML18093A899)
- ML18093A901 + (ML18093A901)
- 05000311/LER-1988-011-01, :on 880523,Tech Spec Surveillance 4.7.10.1.1.c Late Due to Inadequate Communications Between Nuclear Fire Dept Supervision & Station Mgt.Ltr Issued to Station Supervision Addressing Adequate Communications + (ML18093A902)
- ML18093A903 + (ML18093A903)
- ML18093A905 + (ML18093A905)
- 05000272/LER-1988-011-02, :on 880517,monthly Tech Spec Surveillance 4.0.5 for Apr Not Performed for Valve 12SW39.Caused by Personnel Error.Programmatic Review Conducted to Determine Progammatic Improvements Needed + (ML18093A906)
- ML18093A907 + (ML18093A907)
- ML18093A908 + (ML18093A908)
- ML18093A909 + (ML18093A909)
- ML18093A911 + (ML18093A911)
- ML18093A912 + (ML18093A912)
- PNO-I-88-066, on 880622,unit Tripped Following Loss of Vital Instrument Bus Inverter C.Loss Caused Low Reactor Loop Flow Trip.Caused by Loss of Reactor Coolant Pump Breaker Open Indication & Loss of Power.Licensee Initiated Investigation + (ML18093A913)