Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000272/LER-1981-005, Forwards LER 81-005/03L-0 + (ML18085A869)
- ML18085A870 + (ML18085A870)
- 05000272/LER-1981-005-03, /03L-0:on 810128,during Routine Functional Test on Reactor Protection Sys,Safety Injection Signal Failed.Caused by Comparator Unit (Hagan Model 4111082-001) Failure. Defective Module Replaced + (ML18085A871)
- 05000272/LER-1981-004, Forwards LER 81-004/03L-0 + (ML18085A872)
- ML18085A874 + (ML18085A874)
- 05000272/LER-1981-004-03, /03L-0:on 810119,during Daily Surveillance Test on Control Room Emergency Air Conditioning Sys Isolation Dampers,Damper 1CAA3 Failed to Close.Caused by Ice Formation on Louvers.Ice Melted & Damper Returned to Svc + (ML18085A876)
- ML18085A904 + (ML18085A904)
- 05000272/LER-1981-008, Forwards LER 81-008/03L-0 + (ML18085A906)
- ML18085A907 + (ML18085A907)
- 05000272/LER-1981-008-03, /03L-0:on 810124,carriage Guide Wire of Auxiliary Annunciator Typewriter Broke,Resulting in Loss of Containment Sump Level Monitoring Sys.Caused by Equipment Failure.Broken Wire Replaced by Ibm Technician + (ML18085A908)
- ML18085A909 + (ML18085A909)
- ML18085A911 + (ML18085A911)
- ML18085A912 + (ML18085A912)
- ML18085A914 + (ML18085A914)
- ML18085A915 + (ML18085A915)
- ML18085A917 + (ML18085A917)
- ML18085A918 + (ML18085A918)
- ML18085A919 + (ML18085A919)
- ML18085A922 + (ML18085A922)
- 05000311/LER-1980-019-03, /03X-1:on 800820,spurious Signals Caused 2C Sec Safeguards Equipment to Start Three times.2C Sec de-energized.Output Cable Plug Disconnected,Cleared & Tagged to Prevent Energizing Circuits + (ML18085A924)
- ML18085A925 + (ML18085A925)
- 05000272/LER-1979-054, Forwards LER 79-054/01X-2 + (ML18085A926)
- ML18085A927 + (ML18085A927)
- 05000272/LER-1979-054-01, /01X-2:on 790824,three Snubbers on Main Feedwater Line 14 Found Unable to Rotate Around Spherical Rod End Bearings.Lead Screw & Traveling Nut Assembly Failed Due to Excessive Force.Cause Undetermined + (ML18085A928)
- 05000272/LER-1981-014, Forwards LER 81-014/03L-0 + (ML18085A929)
- ML18085A930 + (ML18085A930)
- 05000272/LER-1981-014-03, /03L-0:on 810201,centrifugal Charging Pump 12 Declared Inoperable.Caused by Loss of Oil Overheating Thrust Bearing & Partially Wiping Main Bearing.Bearings Replaced, Oil Reservoir & All Bearing Housing & Oil Lines Flushed + (ML18085A931)
- ML18085A932 + (ML18085A932)
- ML18085A933 + (ML18085A933)
- ML18085A934 + (ML18085A934)
- 05000272/LER-1981-012, Forwards LER 81-012/03L-0 + (ML18085A935)
- ML18085A937 + (ML18085A937)
- ML18085A938 + (ML18085A938)
- ML18085A939 + (ML18085A939)
- 05000272/LER-1981-013, Forwards LER 81-013/03L-0 + (ML18085A940)
- ML18085A941 + (ML18085A941)
- 05000272/LER-1981-012-03, /03L-0:on 810204,fire Pump 2 in Fire Suppression Water Sys Declared Inoperable for Maint on Leaking Inlet Cooling Water Line.Caused by Leaking Corrugated Stainless Steel Hose Connecting Common Cooling Water Piping + (ML18085A942)
- 05000272/LER-1981-013-03, /03L-0:on 810201,centrifugal Charging Pump 12 Declared Inoperable Due to Leak in Pump Oil Cooler.Oil Cooler Replaced + (ML18085A943)
- 05000272/LER-1981-010, Forwards LER 81-010/03L-0 + (ML18085A944)
- ML18085A945 + (ML18085A945)
- 05000272/LER-1981-010-03, /03L-0:on 810126,containment Fan Coil Unit 11 Declared Inoperable in Order to Replace Leaking Spool Piece in Svc Water Line.Due to Reactor Trip,Fan Coil Unit Had to Be Tested & Declared Operational + (ML18085A946)
- ML18085A947 + (ML18085A947)
- ML18085A948 + (ML18085A948)
- ML18085A949 + (ML18085A949)
- ML18085A951 + (ML18085A951)
- ML18085A971 + (ML18085A971)
- ML18085A972 + (ML18085A972)
- ML18085A973 + (ML18085A973)
- ML18085A974 + (ML18085A974)
- ML18085A975 + (ML18085A975)
- 05000272/LER-1981-015, Forwards LER 81-015/03L-0 + (ML18085A978)