Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18024A659 + (ML18024A659)
- 05000260/LER-1978-024-03, /03L-0 on 781219:drywell Air Compressor Suction Valve FCV-32-62 Failed to Close Due to O-ring Failure within Electropneumatic Control Valve FSV-32-62.Latter Valve Replaced & Subsequent Testing Was Satisfactory + (ML18024A660)
- ML18024A661 + (ML18024A661)
- ML18024A662 + (ML18024A662)
- IR 05000259/1978035 + (ML18024A664)
- ML18024A665 + (ML18024A665)
- 05000296/LER-1979-001, Forwards LER 79-001/03L-0 + (ML18024A667)
- ML18024A668 + (ML18024A668)
- 05000296/LER-1979-001-03, /03L-0 on 790111:switch on LIS-3-56B Failed to Trip Reactor Recirculation Pump Motor Generator.Caused by Misadjusted Switch on Yarway Model 4418CE.Switch Recalibr & Tested Satisfactorily + (ML18024A670)
- ML18024A671 + (ML18024A671)
- ML18024A672 + (ML18024A672)
- ML18024A673 + (ML18024A673)
- ML18024A674 + (ML18024A674)
- ML18024A675 + (ML18024A675)
- 05000260/LER-1979-001, Forwards LER 79-001/03L-0 + (ML18024A676)
- ML18024A677 + (ML18024A677)
- 05000260/LER-1979-001-03, /03L-0 on 790113:during Test of high-pressure Injection Coolant Sys,Steam Supply Valve FCV-73-16 Failed to Open,Rendering Sys Inoperative.Caused by Failure of Limitorque Valve Operator Limit Switch + (ML18024A678)
- ML18024A679 + (ML18024A679)
- ML18024A680 + (ML18024A680)
- 05000296/LER-1979-002, Forwards LER 79-002/03L-0 + (ML18024A681)
- ML18024A682 + (ML18024A682)
- 05000296/LER-1979-002-03, /03L-0 on 790117:during Maintenance of Reset Switch,Short Circuit Damaged Power Supply & Sensor Circuit Board,Rendering Fixed Spray Automatic Initiation Circuit for Fire Protection Inoperable + (ML18024A683)
- ML18024A685 + (ML18024A685)
- ML18024A686 + (ML18024A686)
- IR 05000259/1978031 + (ML18024A689)
- ML18024A691 + (ML18024A691)
- IR 05000259/1978036 + (ML18024A693)
- PMNS20180032, Notice of Meeting with Nuclear Industry Groups and Other Stakeholders on Possible Regulatory Process Improvements for Advanced Reactor Designs + (ML18024A695)
- 05000260/LER-1979-003, Forwards LER 79-003/01T-0 + (ML18024A696)
- ML18024A697 + (ML18024A697)
- 05000260/LER-1979-003-01, /01T-0 on 790214:rod Position Info Sys Power Supply Ps X-5 Failed,Causing Loss of Rod Position Indication in Bottom Half of Vertical Core Display.Caused by Failure of Cooling Fan in Trygon Model L5B6-70-OVS4989 + (ML18024A698)
- ML18024A699 + (ML18024A699)
- ML18024A702 + (ML18024A702)
- ML18024A704 + (ML18024A704)
- ML18024A705 + (ML18024A705)
- ML18024A706 + (ML18024A706)
- 05000296/LER-1979-003, Forwards LER 79-003/03L-0 + (ML18024A707)
- ML18024A708 + (ML18024A708)
- 05000296/LER-1979-003-03, /03L-0 on 790202:linear Heat Generation Rate Out of Tech Spec Limits.Caused by Operation Close to Limiting Values & Increase in Reactivity Due to Gadolina Burnup. Greater Margin to Limiting Value Will Be Maintained + (ML18024A709)
- 05000260/LER-1979-002, Forwards LER 79-002/03L-0 + (ML18024A711)
- ML18024A712 + (ML18024A712)
- 05000260/LER-1979-002-03, /03L-0 on 790203:alarm for Fire Protection Panel 25-236 Annunciated in Control Room.Panel Was Not Alarmed Condition.Caused by Normal End of Life Electrical Failure of Annunciator Point Card.Card Replaced & Sys Normalized + (ML18024A713)
- ML18024A714 + (ML18024A714)
- IR 05000259/1978037 + (ML18024A717)
- ML18024A718 + (ML18024A718)
- ML18024A719 + (ML18024A719)
- ML18024A721 + (ML18024A721)
- ML18024A723 + (ML18024A723)
- ML18024A724 + (ML18024A724)
- IR 05000259/1978032 + (ML18024A725)
- ML18024A726 + (ML18024A726)