- 05000316/LER-1979-049-01, /01T-0:on 791218,during Insp of Seismic Class 1 safety-related Piping Sys Per IE Bulletin 79-14,noted Discrepancy in Auxiliary Pipe.Caused by Pipe 3-ft Longer than Specified in Model.Two Addl Restraints Installed + (ML17326A446)
- ML17326A447 + (ML17326A447)
- ML17326A448 + (ML17326A448)
- ML17326A449 + (ML17326A449)
- ML17326A452 + (ML17326A452)
- ML17326A455 + (ML17326A455)
- ML17326A456 + (ML17326A456)
- ML17326A461 + (ML17326A461)
- ML17326A462 + (ML17326A462)
- 05000315/LER-1979-066-03, /03L-0:on 791218,glycol Containment Isolation Valve VCR-10 Did Not Close When Control Switch Turned to Closed Position.Cause Not Known.Valve Operated Properly When Manually Shut + (ML17326A463)
- 05000315/LER-1979-067-03, /03L-0:on 791221,after Update of Axial Power Distribution Monitoring Sys Fz Setpoints,Two of Four Thimbles Used Found Lacking Lowest Sigma.Caused by Personnel Error in Readout.Fz Recalculated Using Correct Thimbles + (ML17326A464)
- 05000315/LER-1979-065-01, /01T-0:on 791224,during in-house Evaluation of Containment Air Recirculation/Hydrogen Skimmer Sys, Discrepancies Noted Between Math Models & Design Drawings. Cause Not Stated.Mods Made to Supports + (ML17326A465)
- 05000316/LER-1979-053, Forwards LER 79-053/03L-0 + (ML17326A466)
- ML17326A467 + (ML17326A467)
- 05000316/LER-1979-053-03, /03L-0:on 791226,while Performing Type B & C Leak Tests Several Valves Exhibited Leakage Exceeding Tech Spec Limit.Caused by Sand Deposits on Valve Seating Surfaces & Pitted Valve Seats on Check Valves + (ML17326A468)
- ML17326A469 + (ML17326A469)
- ML17326A470 + (ML17326A470)
- ML17326A471 + (ML17326A471)
- ML17326A472 + (ML17326A472)
- ML17326A486 + (ML17326A486)
- ML17326A487 + (ML17326A487)
- 05000316/LER-1980-001-03, /03L-0:on 800119,during Normal Startup & W/Power Level at Approx 10%,steam Generators Fed Too Much Feedwater Flow Resulting in Drop in Temp Average to 539 F.Cause Not Stated + (ML17326A490)
- IR 05000324/2017008 + (ML17326A491)
- 05000316/LER-1980-002-03, /03L-0:on 800115,during Integrity Testing of South Safety Injection Train,Excessive Leakage from Safety Injection Valve to Pressurizer Relief Tank Observed.Caused by Undersized Disc Insert.Disc Insert & Nozzle Replaced + (ML17326A494)
- ML17326A499 + (ML17326A499)
- ML17326A500 + (ML17326A500)
- ML17326A501 + (ML17326A501)
- ML17326A502 + (ML17326A502)
- ML17326A503 + (ML17326A503)
- ML17326A507 + (ML17326A507)
- ML17326A510 + (ML17326A510)
- IR 05000315/1979028 + (ML17326A512)
- ML17326A514 + (ML17326A514)
- ML17326A515 + (ML17326A515)
- ML17326A517 + (ML17326A517)
- ML17326A518 + (ML17326A518)
- ML17326A519 + (ML17326A519)
- ML17326A520 + (ML17326A520)
- ML17326A522 + (ML17326A522)
- ML17326A527 + (ML17326A527)
- ML17326A528 + (ML17326A528)
- ML17326A529 + (ML17326A529)
- 05000315/LER-1980-001-03, /03L-0:on 800123,while Performing Airlock Seal Leak Rate Testing,Inner Airlock Declared Inoperable.Caused by Broken Adjustment Bolt.Bolt Will Be Replaced During Next Unit Refueling Outage + (ML17326A530)
- 05000315/LER-1980-002-03, /03L-0:on 800125,during Normal Operation,Loop 3 T-average & delta-T Indication Decreased & Determined Inoperable.Caused by Resistance Temp Detector Producing Erroneous Temp Readings.Detector Was Replaced + (ML17326A531)
- 05000316/LER-1980-003, Forwards LER 80-003/03L-0 + (ML17326A534)
- ML17326A535 + (ML17326A535)
- 05000316/LER-1980-003-03, /03L-0:on 800124,during Surveillance Test,Turbine Driven Auxiliary Feed Pump Trip & Throttle Valve Unlatched. Caused by Burned Up Reset Coil on Trip & Throttle Valve Linkage.Linkage Not Engaging Due to Worn Mating Surfaces + (ML17326A536)
- ML17326A537 + (ML17326A537)
- ML17326A539 + (ML17326A539)
- 05000316/LER-1980-005-03, /03L-0:on 791113,re-evaluation of Calibr Data Taken During Last Refueling Outage Revealed That Steam Line Pressure Transmitter Data Would Result in Nonconservative Differential Steam Line Pressure Setpoint for Loops 3 & 4 + (ML17326A540)
- 05000316/LER-1980-006-03, /03L-0:on 800129,during Surveillance Test on Pressurizer Pressure Protection Set 3,discovered That Bistable 2 PB-457D Tripped at Value Exceeding Tech Specs. Cause Unknown.Bistable Set within Allowable Values + (ML17326A541)