- ML17326A243 + (ML17326A243)
- ML17326A246 + (ML17326A246)
- ML17326A247 + (ML17326A247)
- ML17326A250 + (ML17326A250)
- ML17326A251 + (ML17326A251)
- ML17326A252 + (ML17326A252)
- ML17326A253 + (ML17326A253)
- ML17326A254 + (ML17326A254)
- 05000316/LER-1979-029-03, /03l-0:on 790715,axial Power Distribution Monitoring Sys Detector Set Improperly.Caused by Poor Communication Between Shift Changes.Setpoint Reset.Setpoint Values Posted + (ML17326A255)
- ML17326A256 + (ML17326A256)
- ML17326A260 + (ML17326A260)
- ML17326A261 + (ML17326A261)
- ML17326A262 + (ML17326A262)
- ML17326A263 + (ML17326A263)
- ML17326A264 + (ML17326A264)
- ML17326A265 + (ML17326A265)
- ML17326A266 + (ML17326A266)
- ML17326A267 + (ML17326A267)
- ML17326A268 + (ML17326A268)
- ML17326A270 + (ML17326A270)
- ML17326A271 + (ML17326A271)
- ML17326A272 + (ML17326A272)
- ML17326A273 + (ML17326A273)
- ML17326A274 + (ML17326A274)
- ML17326A275 + (ML17326A275)
- ML17326A276 + (ML17326A276)
- ML17326A277 + (ML17326A277)
- 05000315/LER-1979-046-03, /03L-0:on 790905,during Full Length Control Rod Operability Test,Urgent Failure Alarm from Power Cabinet 2AC Was Received on Rod Control.Cause Could Not Be Found.Power Supply Reset & Operability Test Satisfactorily Completed + (ML17326A278)
- 05000315/LER-1979-047-03, /03l-0:on 790908,circuit Breakers FMO-241,breaker- to-engineered Safety Feature Ventillation Fan 2 & breaker- to-A Train Heat Trace Circuits Found Open.Cause Not Identified.Breakers Reclosed & keep-free Areas Established + (ML17326A279)
- ML17326A280 + (ML17326A280)
- ML17326A281 + (ML17326A281)
- 05000316/LER-1979-031-03, /03L-0:on 790912,elevation Containmment Airlock Interlock at 612 Ft Did Not Prevent Opening of Outer Door W/Inner Door Open.Caused by Flexing of One Interlock Support Bracket.Gusset Added to Bracket + (ML17326A282)
- 05000316/LER-1979-030-03, /03L-0:on 790909,while at 81% Power,Delta Flux Indication Was Below Tech Spec Limit.Caused by Operator Error.Procedures Have Been Revised + (ML17326A283)
- 05000316/LER-1979-032-03, /03L-0:on 790911,during Surveillance Test,High Pressure Reactor Trip Bistable Found to Trip at Setpoint Corresponding to 2417 Psig.Caused by Defective Bistable. Bistable Replaced + (ML17326A284)
- ML17326A285 + (ML17326A285)
- ML17326A286 + (ML17326A286)
- ML17326A287 + (ML17326A287)
- ML17326A288 + (ML17326A288)
- 05000315/LER-1979-048-03, /03L-0:on 790917,sample Pump for Radiation Monitor Was Inoperable Due to Failed motor-to-pump Coupling Insert. Caused by Failure of Rubber Spider in Coupling.Coupling Was Replaced & Air Sampler Tested + (ML17326A289)
- 05000316/LER-1979-033-03, /03L-0:on 790930,steam Generator Stop Valve Dump 3 Failed to Open.Caused by Open Coil for Solenoid Valve.Coil Replaced & Proper Action Verified + (ML17326A290)
- ML17326A292 + (ML17326A292)
- 05000315/LER-1979-049-03, /03L-0:on 790924,during Review of Axial Power Distribution Monitoring Sys Readout,Discovered That Sys Failed to Perform Tech Spec Surveillance Requirement F(Z). Caused by Direction Relay Sticking on Detector Drive 4 + (ML17326A293)
- 05000315/LER-1979-050-03, /03L-0:on 790929,during Surveillance Test,Steam Generator Water Level low-low Bistable Drifted Excessively. Caused by Defective Bistable.Bistable Replaced,Calibr,Tested & Returned to Svc + (ML17326A294)
- ML17326A295 + (ML17326A295)
- 05000316/LER-1979-034-03, /03L-0:on 790926,sample Pump for Radiation Monitors R-11 & R-12 Tripped at Frequent Intervals on Two Occasions.Cause Unknown.Pumps Replaced & Tested Satisfactorily.Pumps Scheduled for Periodic Replacement + (ML17326A296)
- ML17326A297 + (ML17326A297)
- ML17326A298 + (ML17326A298)
- ML17326A299 + (ML17326A299)
- ML17326A302 + (ML17326A302)
- ML17326A303 + (ML17326A303)
- 05000315/LER-1979-051, Forwards LER 79-051/03L-0 + (ML17326A304)