- ML17317B048 + (ML17317B048)
- 05000315/LER-1979-014-03, /03L-0 on 790301:while in Mode 1,indicated Position of Rod F-6 Discovered to Be Oscillating within 15 Steps of Bank Demand Position.Caused by Signal Conditioning Module Connector.Cleaning & Reinstallation Corrected Limits + (ML17317B049)
- 05000315/LER-1979-015-03, /03L-0 on 790302:while Operating at Full Power, Pressurizer Relief Tank Rupture Disc Blew Out,Causing Ice Condenser Inlet Doors to Open.Caused by Pressure Fluctuations Resulting in Weakened Rupture Discs + (ML17317B050)
- ML17317B052 + (ML17317B052)
- ML17317B053 + (ML17317B053)
- ML17317B054 + (ML17317B054)
- ML17317B056 + (ML17317B056)
- ML17317B057 + (ML17317B057)
- ML17317B059 + (ML17317B059)
- 05000316/LER-1979-009, Forwards LER 79-009/03L-0 + (ML17317B060)
- ML17317B062 + (ML17317B062)
- 05000316/LER-1979-009-03, /03L-0 on 790303:2W Svc Water Pump Amp Pegged Meter Stopped,Constituting Inoperable Pump.Caused by Burr Formed Between Impeller Ring & Bowl.Pump Shaft & Bowl Replaced + (ML17317B063)
- 05000316/LER-1979-010, Forwards LER 79-010/03L-0 + (ML17317B064)
- ML17317B065 + (ML17317B065)
- 05000316/LER-1979-010-03, /03L-0 on 790306:during Surveillance Test on Turbine Driven Auxiliary Feed Pump,Pump Was Over Max Recommended Temp.Possible Cause Was Foreign Matl in Bearing Oil.Oil Was Changed + (ML17317B066)
- ML17317B067 + (ML17317B067)
- ML17317B068 + (ML17317B068)
- 05000315/LER-1979-016-03, /03L-0 on 790304:two Manual Containment Isolation Valves Were Inadvertantly Left Open Following Routine Sample of Instrument Room.Caused by Personnel Oversight.Both Valves Were Returned to Their Normally Closed Positions + (ML17317B069)
- 05000315/LER-1979-017-03, /03L-0 on 790312:spent Fuel Pit Exhaust Ventilation Unit Flow Failed to Meet Acceptance Criteria. Caused by Slight Closing of Intake Grills Due to Sys Vibration.Grill Damper Linkage Securely Fastened + (ML17317B070)
- ML17317B073 + (ML17317B073)
- ML17317B074 + (ML17317B074)
- ML17317B075 + (ML17317B075)
- ML17317B076 + (ML17317B076)
- ML17317B081 + (ML17317B081)
- ML17317B083 + (ML17317B083)
- 05000315/LER-1979-018, Forwards LER 79-018/03L-0 + (ML17317B084)
- ML17317B085 + (ML17317B085)
- 05000315/LER-1979-018-03, /03L-0 on 790310:root Valve for Lower Containment Pressure Transmitter PPP-300 Was Found in Closed Position. Cause Unknown.Valve Was Immediately Opened,Restoring Loop to Operable Status + (ML17317B086)
- ML17317B088 + (ML17317B088)
- ML17317B091 + (ML17317B091)
- ML17317B093 + (ML17317B093)
- ML17317B094 + (ML17317B094)
- ML17317B095 + (ML17317B095)
- ML17317B096 + (ML17317B096)
- ML17317B097 + (ML17317B097)
- ML17317B098 + (ML17317B098)
- ML17317B100 + (ML17317B100)
- ML17317B102 + (ML17317B102)
- ML17317B103 + (ML17317B103)
- ML17317B104 + (ML17317B104)
- ML17317B105 + (ML17317B105)
- ML17317B107 + (ML17317B107)
- ML17317B109 + (ML17317B109)
- ML17317B110 + (ML17317B110)
- ML17317B111 + (ML17317B111)
- 05000315/LER-1979-020-03, /03L-O on 790323:pressurizer Relief Tank Rupture Disk Blew Out While in Mode 3.Caused by Repeated Pressure Fluctuations Causing Rupture Disk to Weaken.Corrective Action Unnecessary Since Doors Functioned as Designed + (ML17317B112)
- 05000315/LER-1979-021-03, /03L-0 on 790327:pressure in RCS Was Found Below Tech Spec Limit While in Mode 1.Caused by Operator Inadvertantly Opening Auxiliary Spray Valve to Pressurizer QRV-51.Valve Closed Upon Discovery + (ML17317B114)
- ML17317B115 + (ML17317B115)
- 05000316/LER-1979-011, Forwards LER 79-011/03L-0 + (ML17317B116)
- ML17317B117 + (ML17317B117)
- 05000316/LER-1979-011-03, /03L-0 on 790327:outer Door Seal of Lower Containment Air Lock Found Leaking.Caused by Force Placed on Seal During Installation of Security Gate at Air Lock Entrance.Seal Tightened & Outer Seal Retested + (ML17317B118)