- ML17285B037 + (ML17285B037)
- ML17285B040 + (ML17285B040)
- ML17285B042 + (ML17285B042)
- 05000397/LER-1990-003, :on 900126,HPCS Sys Pump Suction Valve Switchover Occurred During Performance of Procedure for Draining Ref Leg.Caused by Plant Configuration.Sys Restored to pre-event Lineup Status + (ML17285B047)
- ML17285B050 + (ML17285B050)
- IR 05000397/1990002 + (ML17285B051)
- GO2-90-032, Application for Amend to License NPF-21,allowing Use of Cycle 6 Reload Fuel in Plant.Changes to Listed Tech Specs Requested.Supporting Reload Analysis Repts Encl.Proprietary GE & ABB Atom Repts Withheld (Ref 10CFR2.790(b)(4)) + (ML17285B052)
- ML17285B053 + (ML17285B053)
- ML17285B054 + (ML17285B054)
- ML17285B055 + (ML17285B055)
- ML17285B056 + (ML17285B056)
- ML17285B057 + (ML17285B057)
- GO2-90-031, Forwards Washington Nuclear Plant-2 Semiannual Radioactive Effluent Release Rept,Jul-Dec 1989 & Amend 7 to Odcm + (ML17285B058)
- ML17285B059 + (ML17285B059)
- ML17285B060 + (ML17285B060)
- ML17285B062 + (ML17285B062)
- GO2-90-029, Informs of Delay of Equipment Setpoint Methodology Program Plan.New Schedule Will Be Provided within 30 Days of Ltr Date + (ML17285B063)
- ML17285B064 + (ML17285B064)
- GO2-90-026, Annual Personnel Monitoring Rept for WPPS-2 for CY89. W/ + (ML17285B065)
- GO2-90-037, Application for Amend to License NPF-21,revising Tech Spec 3.8.1.1, AC Sources, to Eliminate Unnecessary Starts,Per Generic Ltr 84-15 & to Allow Plant Resources to Focus on Restoring Equipment to Operable Status + (ML17285B068)
- ML17285B069 + (ML17285B069)
- ML17285B070 + (ML17285B070)
- GO2-90-036, Application for Amend to License NPF-21,revising Battery Load Profiles in Surveillance Requirement 4.8.2.1.d.2 to Reflect Results of Recent Reviews of Battery Capabilities + (ML17285B071)
- ML17285B072 + (ML17285B072)
- ML17285B073 + (ML17285B073)
- GO2-90-034, Responds to NRC Re Violations Noted in Insp Rept 50-397/89-30.Corrective Action:Plant Personnel Currently in Process of Making Improvements to Plant Operations Procedure Writers Guide + (ML17285B074)
- ML17285B075 + (ML17285B075)
- ML17285B077 + (ML17285B077)
- IR 05000397/1989040 + (ML17285B078)
- ML17285B080 + (ML17285B080)
- 05000397/LER-1989-033, :on 890811,RWCU Isolation Occurred When Fuse in Power Supply to Leak Detection Monitor Blew,Giving False High Alarm Signal to Isolation Logic.Cause Unknown.Fuse Replaced & RWCU Sys Restored to Operation + (ML17285B082)
- 05000397/LER-1989-038, :on 890121,two 3/8-inch Drain Line Valves Associated W/Standby Liquid Control Flow Transmitter Not Labeled & Not Contained in Checklist.Caused by Inadequate Procedures.Walkdown Will Be Conducted + (ML17285B083)
- RS-17-139, Second Updated Response to NRC Regulatory Issue Summary 2017-03, Preparation and Scheduling of Operator Licensing Examinations + (ML17285B084)
- GO2-90-033, Forwards Compilation of Responses to Regulatory Impact Survey Questionnaire,Per Generic Ltr 90-01 + (ML17285B086)
- NL-17-1097, Proposed Alternatives FNP-ISI-AL T-05-02 and VEGP-ISI-AL T-04-02 in Accordance with 10 CFR 50.55a(z)(2) Hardship Without a Compensating Increase in Quality and Safety + (ML17285B088)
- GO2-90-035, Forwards Supplementary Info Re 900214 Application for Amend to License NPF-21,revising Tech Spec 3.3.7.5 to Address Failed Safety/Relief Valve Position Indicators + (ML17285B093)
- ML17285B094 + (ML17285B094)
- ML17285B095 + (ML17285B095)
- ML17285B097 + (ML17285B097)
- ML17285B101 + (ML17285B101)
- ML17285B103 + (ML17285B103)
- ML17285B104 + (ML17285B104)
- ML17285B105 + (ML17285B105)
- GO2-90-038, Application for Amend to License NPF-21,revising Tech Spec 3.4.2, Safety Relief Valves & Tables 3.3.7.5-1 & 4.3.7.5-1, Accident Monitoring Instrumentation, to Allow Monitor on Safety Valves to Be Inoperable Until Shutdown + (ML17285B106)
- ML17285B107 + (ML17285B107)
- ML17285B108 + (ML17285B108)
- ML17285B109 + (ML17285B109)
- 05000397/LER-1990-004, :on 900208,HPCS Diesel Generator Declared Inoperable for Performance of Corrective Maint to Investigate Previous Trip of Output Circuit Breaker Which Occurred on 900204.New Droop Switch Installed + (ML17285B110)
- 05000397/LER-1990-005, :on 900209,nonsafety-related Circuit Breaker on Power Panel Tripped,Resulting in ESF Actuation.Caused by Equipment Mfg Error Involving Defect in Circuit Breaker Tripping Mechanism.Defective Breaker Replaced + (ML17285B111)
- GO2-90-050, Provides Level of Property & Liability Insurance Coverage for Facility,Per 10CFR50.54(w)(2) Annual Requirement + (ML17285B112)