Issue date | Title | |
---|---|---|
ML18127B723 | 14 May 2018 | Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: May 22, 2018 |
ML16243A515 | 30 August 2016 | License Amendment Request for Reclassifying Quality Group of Low Temperature Portions of Reactor Water Cleanup System |
ML15355A496 | 21 December 2015 | Final Safety Analysis Report, Amendment 63, Chapter 3 - Design Criteria - Structures, Components, Equipment, and Systems, Table of Contents |
GO2-16-021, R02 15-5462, Revision a, Expedited Seismic Evaluation Process (ESEP) Report | 27 October 2015 | R02 15-5462, Revision a, Expedited Seismic Evaluation Process (ESEP) Report |
GO2-15-039, TIA XXXX-XX, Tower Makeup System Unresolved Issue | 6 March 2015 | TIA XXXX-XX, Tower Makeup System Unresolved Issue |
IR 05000397/2014003 | 6 August 2014 | IR 05000397-14-003; 03/24/2014 - 06/23/2014; Columbia Generating Station; Equipment Alignment, License Operator Requalification Program and Licensed Operator Performance, Occupational ALARA Planning and Controls, Problem Identification & Re |
ML14010A295 | 30 December 2013 | Final Safety Analysis Report, Amendment 62, Chapter 3 - Design Criteria - Structures, Components, Equipment, and Systems, Table of Contents Through 3.5-46 |
ML12011A154 | 14 December 2011 | Amendment 61 to Final Safety Analysis Report, Chapter 3, Design Criteria - Structures, Components, Equipment, and Systems |
Information Notice 1996-64, Modifications to Containment Blowout Panels Without Appropriate Design Controls | 10 December 1996 | Modifications to Containment Blowout Panels Without Appropriate Design Controls |
ML17289B155 | 9 February 1993 | Requests for Temporary Relief from Tornado Missile Design Criteria as It Relates to Protective Soil Cover Requirements Above Underground safety-related Diesel Oil Storage Tanks |
ML20213E474 | 22 July 1983 | Requests Input to SER Suppl 4 by 830815.Marked-up Copy of SER Suppl 3,Sections 1.7,1.8 & 1.9,listing Status of All Open & Confirmatory Items,Encl |
ML20213E330 | 25 February 1983 | Forwards Suppl to SER Chapter 9,covering Blockage of Diesel Generator Combustion Air Intake & Exhaust Sys Due to Various Meteorological Conditions & Tornado Missile Protection of Exhaust Sys |
ML20213E322 | 4 February 1983 | Forwards Rev 3 to Auxiliary Sys Branch SER Input,Section 3.5.2, Structures,Sys & Components to Be Protected from Externally Generated Missiles. No Tornado Missile Protection for Diesel Exhausts Necessary |
ML20213E229 | 6 August 1982 | Discusses 820723 Submittal Re Protection of Diesel Generator Exhausts from Tornado Missiles.Applicant Must Select Either Alternative 1,control of Bluff or Alternative 2,providing Missile Barrier,Contained in O Parr 820611 Memo |
ML17276B585 | 5 August 1982 | Clarifies Diesel Generator Bldg Air Intake Per Discussion Re Design Basis Dust Storm Effect.Response Closes Out SER Outstanding Concern |
ML17276B559 | 23 July 1982 | Comments on NRC 820629 Response to 820514 Ltr Re Tornado Missile Protection for Diesel Generator Exhausts.Backfitting Would Not Justify Cost.Requests Item Be Deleted from SER Open Item List |
ML20213E179 | 11 June 1982 | Discusses Tornado Missile Protection for Diesel Generator Exhausts,In Response to 820605 Memo.Licensee Should Either Assure That No Loose Matl Will Be Stored in Bluff Area or That Failure of Exhaust Will Not Result in Diesel Failure |
ML17276B448 | 14 May 1982 | Provides Justification for Adequacy of Present Design Re Tornado Missile Protection for Diesel Generator Exhausts. New SRP Requirement Should Not Be Imposed.Removal of Item from SER Outstanding Issue List Requested.Rept Encl |
ML20213E129 | 7 April 1982 | Forwards Review Questions from USGS Re Site Region.W/O Encl |
ML20213E107 | 24 March 1982 | Forwards Revised Sections 9.3.1,9.1.4,9.4.8 & 9.4.4 of 820219 SER Input,Based on Addl Info Received on 820129,0222 & 25 & 0302 |
ML17276B131 | 1 March 1982 | Forwards Addl Info Re Control Room Chillers & One Oversize Drawing of Diesel Generator Exhaust Line Configuration Showing Tornado Missile Protection,Per NRC 820219 Request. Aperture Card Is Available in PDR |
ML17276A971 | 14 January 1982 | Forwards Response to Draft SER Open Issues & Outstanding Open Branch Meeting Issues |
ML20213D833 | 14 October 1981 | Forwards Auxiliary Sys Branch Draft SER Up to & Including Amend 17 to Fsar.Open Items Include Internally Generated Missiles,Structures,Sys & Components to Be Protected,Fuel Handling Sys & MSIV Leakage Control Sys |