Semantic search

Jump to navigation Jump to search
 Issue dateTitle
L-MT-23-005, Response to the NRC Request for Additional Information Regarding the 50.55a Request Pr 08, HPCI Pump Quarterly Testing (EPID Number L-2022-LLR-0088)6 January 2023Response to the NRC Request for Additional Information Regarding the 50.55a Request Pr 08, HPCI Pump Quarterly Testing (EPID Number L-2022-LLR-0088)
IR 05000263/202001313 October 2020Design Basis Assurance Inspection (Programs) Inspection Report 05000263/2020013
IR 05000263/20200023 August 2020Integrated Inspection Report 05000263/2020002
ML17352A67318 December 2017Submittal of Anchor Darling Double Disc Gate Valve Information and Status
ML17319A59110 December 2017Safety Evaluation Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Pool Instrumentation Related to Orders EA-12-049 and EA-12-051
L-MT-17-066, Supplemental Information for the Notification of Full Compliance of Required Action for NRC Order EA-12-049 Mitigation Strategies for Beyond-Design-Basis External Events28 September 2017Supplemental Information for the Notification of Full Compliance of Required Action for NRC Order EA-12-049 Mitigation Strategies for Beyond-Design-Basis External Events
IR 05000263/201700211 August 2017NRC Integrated Inspection Report 05000263/2017002
ML17194A82511 July 2017Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections
05000263/LER-2017-00314 June 2017Main Steam Isolation Valve Leakage Exceeds Technical Specification Limits
LER 17-003-00 for Monticello Regarding Main Steam Isolation Valve Leakage Exceeds Technical Specification Limits
ML16321A45031 August 2016Part 21 Notification - Flowserve Swing Check Valves
ML13064A01225 February 2013Notification of Potential Part 21 Report Re Wedge Pin Failure of an Anchor/Darling Double-Disc Gate Valve
L-MT-12-018, Fifth Ten-Year Lnservice Inspection Plan28 February 2012Fifth Ten-Year Lnservice Inspection Plan
L-MT-09-078, Submittal of Cycle No. 24 Inservice Inspection Summary Report for Inservice Inspection and ASME Section Xl Repairs and Replacements7 August 2009Submittal of Cycle No. 24 Inservice Inspection Summary Report for Inservice Inspection and ASME Section Xl Repairs and Replacements
ML05208048527 July 2005IR 05000263-05-003, on 04/01/2005, for Monticello Nuclear Generating Plant; Operability Evaluations and Event Follow-Up
Information Notice 1996-08, Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate Valve5 February 1996Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate Valve
Information Notice 1994-55, Problems with Copes-Vulcan Pressurizer Power-Operated Relief Valves4 August 1994Problems with Copes-Vulcan Pressurizer Power-Operated Relief Valves
Information Notice 1993-77, Human Errors That Result in Inadvertent Transfers of Special Nuclear Material at Fuel Cycle Facilities4 October 1993Human Errors That Result in Inadvertent Transfers of Special Nuclear Material at Fuel Cycle Facilities
Information Notice 1993-16, Failures of Not-Locking Devices in Check Valves19 February 1993Failures of Not-Locking Devices in Check Valves
ML20125C7167 December 1992Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils Encl
Information Notice 1992-67, Deficiency in Design Modifications to Address Failures of Hiller Actuators Upon a Gradual Loss of Air Pressure10 September 1992Deficiency in Design Modifications to Address Failures of Hiller Actuators Upon a Gradual Loss of Air Pressure
Information Notice 1992-41, Consideration of Stem Rejection Load In Calculation of Required Valve Thrust29 May 1992Consideration of Stem Rejection Load In Calculation of Required Valve Thrust
Information Notice 1992-41, Consideration of Stem Rejection Load in Calculation of Required Valve Thrust29 May 1992Consideration of Stem Rejection Load in Calculation of Required Valve Thrust
NRC Generic Letter 1991-1717 October 1991NRC Generic Letter 1991-017: Generic Safety Issue 29, Bolting Degradation or Failure in Nuclear Power Plants.
Information Notice 1989-56, Questionable Certification of Material Supplied to the Defense Dept. By Nuclear Suppliers22 November 1989Questionable Certification of Material Supplied to the Defense Dept. By Nuclear Suppliers
Information Notice 1989-56, Questionable Certification of Material Supplied to the Defense Dept. by Nuclear Suppliers22 November 1989Questionable Certification of Material Supplied to the Defense Dept. by Nuclear Suppliers
Information Notice 1988-90, Unauthorized Removal of Industrial Nuclear Gauges22 November 1988Unauthorized Removal of Industrial Nuclear Gauges
Information Notice 1988-92, Potential for Spent Fuel Pool Draindwon22 November 1988Potential for Spent Fuel Pool Draindwon
Information Notice 1988-89, Degradation of Kapton Electrical Insulation21 November 1988Degradation of Kapton Electrical Insulation
Information Notice 1988-87, Pump Wear and Foreign Objects in Plant Piping Systems16 November 1988Pump Wear and Foreign Objects in Plant Piping Systems
Information Notice 1988-88, Degradation of Westinghouse Ard Relays16 November 1988Degradation of Westinghouse Ard Relays
Information Notice 1988-86, Operating with Multiple Grounds in Direct Current Distribution Systems21 October 1988Operating with Multiple Grounds in Direct Current Distribution Systems
Information Notice 1988-85, Broken Retaining Block Studs on Anchor Darling Check Valves14 October 1988Broken Retaining Block Studs on Anchor Darling Check Valves
Information Notice 1987-08, Degraded Motor Leads in Limitorque DC Motor Operators4 February 1987Degraded Motor Leads in Limitorque DC Motor Operators
ML20199L64726 June 1986Summary of Operating Reactors Events Meeting 86-21 on 860623.Attendance List & Viewgraphs Encl