Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML16265A00923 September 2016Acceptance of Requested Licensing Action License Amendment Request to Change Technical Specifications to Allow the Use of Optimized Zirlo Fuel Rod Cladding Material
ML16262A21320 September 2016LLC - Final Significance Determination for a White Finding with Assessment Follow-up and Notice of Violation - Inspection Report 05000244/2016009Significance Determination Process
Preliminary White Finding
IR 05000244/201600920 September 2016LLC - Final Significance Determination for a White Finding with Assessment Follow-up and Notice of Violation - Inspection Report 05000244/2016009Significance Determination Process
Preliminary White Finding
CAC:MF823820 September 2016
ML16253A12520 September 2016Fleet License Amendment Request to Revise Technical Specification Requirements for Inservice Testing Program (CAC Nos. MF8238 - MF8256)
ML16258A38615 September 2016EN-16-021, Issuance of Final Significance Determination and Notice of Violation to Ginna, (EA-16-128)Significance Determination Process
ML16230A2376 September 2016Fleet Request for Proposed Alternative to Use ASME Code Case N-513-4 (CAC Nos. MF7301-MF7322)Incorporated by reference
Through-Wall Leak
ML16321A45031 August 2016Part 21 Notification - Flowserve Swing Check ValvesAnchor Darling
IR 05000244/201600531 August 2016Mid-Cycle Assessment Letter for R.E. Ginna Nuclear Power Plant, (Report 0500244/2016005)Spent Fuel Pool Instrumentation
ML16252A27429 August 2016Azz/Nli - Part 21 Report - Potential Allen Bradley Timing Relay
ML16235A14829 August 2016Project Manager Assignment
ML16243A47426 August 2016Potential Part 21 Unqualified Component in Certain Allen Bradley Timing Relays
ML16229A23926 August 2016R. E. Ginna Nuclear Power Plant - Correction Letter to License Amendment No. 115 Issuance of Amendment to Conform the Renewed Facility Operating License to Reflect the Direct Transfer of Operating Authority
CAC:MF258826 August 2016
ML16236A09626 August 2016R. E. Ginna - Correction Letter to License Amendment No. 122 Licence Amendment Request to Relocate Specific Surveillance Frequency Requirements to a Licensee Controlled Program - Adoption of TSTF-425, Revision 3Surveillance Frequency Control Program
CAC:MF830022 August 2016
CAC:MF829922 August 2016
ML16236A30022 August 2016License Amendment Request and 10 CFR 50.12 Exemption Request for the Use of Optimized Zirlo Fuel Rod CladdingShutdown Margin
Hydrostatic
Pressure and Temperature Limits Report
Exemption Request
Fuel cladding
IR 05000244/201600218 August 2016LLC - Integrated Inspection Report 05000244/2016002 with Preliminary White Finding, and Independent Spent Fuel Storage Installation Report 07200067/2016001Fire Barrier
Internal Flooding
Nondestructive Examination
Temporary Modification
Functionality Assessment
Significance Determination Process
Process Control Program
Operability Determination
Preliminary White Finding
Operability Assessment
ML16228A06215 August 2016Summary of July 26, 2016, Public Meeting on Status of Associated Effects Submittals Related to the Reevaluated Flood Hazards at Exelon Generation Company, LLC Sites as Part of the Response to Near-Term Task Force Recommendation 2.1, FloodinTornado Generated Missile
ML16229A44515 August 2016Interim Part 21 Report Regarding Internal Pump Tolerances Between the Impeller Hub and a Wear Ring
ML16232A60415 August 2016Potentially Unqualified Component in Certain Allen Bradley Timing Relays
ML16238A18615 August 2016Update - Report of Potential l0CFR Part 21, Allen Bradley Timing Relay Model 700RTC-NRC Event Number 51030, Accession Number ML15134A016
ML16209A49626 July 2016Relief Request for Alternative to ASME CodeIncorporated by reference
ML16209A21826 July 2016Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Lnservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing.Shutdown Margin
Reactor Vessel Water Level
Packing leak
High Radiation Area
Stroke time
Hydrostatic
Squib
Incorporated by reference
Missed surveillance
Surveillance Frequency Control Program
Excess Flow Check Valve
Power Operated Valves
Pressure Boundary Leakage
Recently irradiated fuel
Power change
Unidentified leakage
ML16207A11314 July 2016Radiological Emergency Plan Annex RevisionsSafe Shutdown
Health Physics Network
High Radiation Area
Grab sample
Offsite Dose Calculation Manual
Cyber Security
Emergency Lighting
B.5.b
Severe Accident Management Guideline
Earthquake
Minimum staff
Scaffolding
Inadvertent Siren Activation
Siren
Exclusive Use
Overexposure
ML16209A05414 July 2016Independent Spent Fuel Storage Installation, Nine Mile Point, Units 1 and 2, R.E. Ginna, Nuclear Radiological Emergency Plan Annex RevisionsSafe Shutdown
Cyber Security
ML16124A03814 July 2016Safety Evaluation Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Pool Instrumentation Related to Orders EA-12-049 and EA-12-051Safe Shutdown
Boric Acid
High winds
Shutdown Margin
Loop seal
High Radiation Area
Ultimate heat sink
Mission time
Tornado Missile
Safe Shutdown Earthquake
Internal Flooding
Emergency Lighting
FLEX
Tornado Generated Missile
Fukushima Dai-Ichi
Tornado Missile Protection
Spent Fuel Pool Instrumentation
Severe Accident Management Guideline
Frazil ice
Earthquake
Fire Protection Program
Coast down
ML16190A3858 July 2016EP-AA-1 12-100-F-50, Revision D, Shift Emergency Director Checklist (Cng), Emergency Implementing ProcedureSafe Shutdown
Health Physics Network
Ultimate heat sink
FLEX
Severe Accident Management Guideline
Minimum staff