Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML20246A226 | 28 April 1989 | Forwards Sser Re Steam Generator Tube Vibration for CESSAR Sys 80 Design.Concurs W/Licensee That Adequate Steam Generator Tube Integrity Can Be Assured at Each Plant Through Appropriate Program of Preventive Tube Plugging | |
ML20195D225 | 1 November 1988 | Forwards Request for Addl Info Re Amend C of Chapters 5,6 & 10 of CESSAR-DC,Sys 80+.Info Requested within 90 Days of Ltr Receipt | |
ML20205N485 | 28 October 1988 | Forwards Request for Addl Info Re Chapter 5,Amend C to CESSAR-DC,Sys 80+ on Steam Generators.Info Needed by 881230 | |
ML20195B901 | 26 October 1988 | Forwards Request for Addl Info Re 880930 Submittal of Amend D to Chapters 4,5,6 & 10 of CESSAR-DC,Sys 80+.Info Requested within 90 Days from Receipt of Ltr | Liquid penetrant |
ML20151N344 | 3 August 1988 | Forwards Request for Addl Info Re Chapter 9, Auxiliary Sys, & Chapter 5, RCS, CESSAR-DC,Sys 80+ in Order to Continue Review of Amend B | Ultimate heat sink Pressure Boundary Leakage |
ML20151R028 | 2 August 1988 | Discusses QA for CESSAR-DC,Sys 80+ & Significant Points Made Listed | |
ML20153B141 | 28 June 1988 | Requests Addl Info Re Amend B of Chapters 5 & 9 of CESSAR-DC,Sys 80+ for Review Completion | |
ML20153B128 | 28 June 1988 | Forwards Request for Addl Info Re Amend B of Chapters 4 & 5 of CESSAR-DC,Sys 80+,transmitted by .Receipt of Info within 90 Days of Ltr Date Requested | |
ML20148B510 | 15 March 1988 | Informs of Relocation of NRR to Stated Address in Rockville,Md | |
ML20236A726 | 13 October 1987 | Responds to Re Creation of New Docket for CESSAR-DC.Creation of New Docket Will Facilitate Recordkeeping & Minimize Confusion for Vendor & NRC | Backfit |
ML20205L697 | 27 March 1987 | Requests Further Info & Documentation Re Steam Generator Tube Vibration Problem for Generic CESSAR Sys 80 Steam Generator Design by 870410.Specific Questions Re Request Encl | Flow Induced Vibration |
ML20205F471 | 24 March 1987 | Requests Sufficient Info to Establish That Auxiliary Pressurizer Spray Sys for CESSAR Sys 80 & Associated Water Supply Sys Safety Grade | |
ML20141K523 | 17 January 1986 | Lists Types of Applications Which Fall Under 6-month Billing Process Per 840620 Rev to 10CFR170, Fees for Facilities & Matls Licenses & Other Regulatory Svcs.... Bills Will Be Issued in Dec & June | |
ML20135A103 | 23 August 1985 | Forwards Exam Rept 50-470/85-01 Administered During Wk of 850617 | |
ML20134D199 | 14 August 1985 | Forwards Final Draft of CESSAR Sys 80 NSSS STS for Review. Certification Under Oath or Affirmation Requested by 850822, If in Agreement W/Final Draft.W/O Encl | |
ML20150D102 | 22 November 1978 | Finds Recipient Has Not Addressed All Matters Required for CESSAR Sys 80 Preliminary Design Analysis Extension.When Info Is received,PDA-2 Will Be Extended for 2 Addl Years | |
ML20148H345 | 3 November 1978 | Ack Receipt of Ce'S Appl for Final Design Approval-Alternate 1 for CE Sys 80 NSSS & Supporting Documentation & Fees |