LR-N23-0011, In-Service Inspection Activities - 90 Day Report: Twenty-Fourth Refueling Outage | 19 January 2023 | In-Service Inspection Activities - 90 Day Report: Twenty-Fourth Refueling Outage | |
LR-N21-0059, In-Service Inspection Activities - 90 Day Twenty-Third Refueling Outage | 13 August 2021 | In-Service Inspection Activities - 90 Day Twenty-Third Refueling Outage | |
LR-N20-0011, In-Service Inspection Activities - 90 Day Report Twenty Second Refueling Outage | 3 February 2020 | In-Service Inspection Activities - 90 Day Report Twenty Second Refueling Outage | Weld Overlay |
LR-N18-0124, Correction to In-Service Inspection Activities - 90 Day Report, Nineteenth Refueling Outage | 14 November 2018 | Correction to In-Service Inspection Activities - 90 Day Report, Nineteenth Refueling Outage | |
LR-N18-0079, In-Service Inspection Activities - 90 Day Report Twenty First Refueling Outage | 8 August 2018 | In-Service Inspection Activities - 90 Day Report Twenty First Refueling Outage | |
LR-N17-0127, Request to Use a Later Edition of the American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants, 2012 Edition with No Addenda, for the Fourth Inservice Test Interval | 17 August 2017 | Request to Use a Later Edition of the American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants, 2012 Edition with No Addenda, for the Fourth Inservice Test Interval | Incorporated by reference |
LR-N16-0238, In-Service Inspection Activities - 90 Day Report Twentieth Refueling Outage | 11 January 2017 | In-Service Inspection Activities - 90 Day Report Twentieth Refueling Outage | |
LR-N15-0250, Lnservice Testing (IST) Program - Fourth Ten-Year Interval | 18 December 2015 | Lnservice Testing (IST) Program - Fourth Ten-Year Interval | Incorporated by reference Surveillance Frequency Control Program Grace period |
LR-N15-0157, Inservice Inspection Activities - 90 Day Report Nineteenth Refueling Outage | 30 July 2015 | Inservice Inspection Activities - 90 Day Report Nineteenth Refueling Outage | |
LR-N14-0037, Inservice Inspection Activities - 90 Day Report Eighteenth Refueling Outrage | 7 February 2014 | Inservice Inspection Activities - 90 Day Report Eighteenth Refueling Outrage | Coatings |
LR-N12-0292, Submittal of Program for Hope Creek Third Ten-Year Interval Inservice Testing Program | 30 August 2012 | Submittal of Program for Hope Creek Third Ten-Year Interval Inservice Testing Program | Safe Shutdown Ultimate heat sink Stroke time Squib Incorporated by reference Locked High Radiation Area Scram Discharge Volume Excess Flow Check Valve Operability Determination Cold shutdown justification Power-Operated Valves Power Operated Valves |
LR-N12-0218, Inservice Inspection Activities - 90 Day Report Seventeenth Refueling Outage | 19 July 2012 | Inservice Inspection Activities - 90 Day Report Seventeenth Refueling Outage | |
LR-N11-0043, Inservice Inspection Activities - 90 Day Report Sixteenth Refueling Outage | 3 February 2011 | Inservice Inspection Activities - 90 Day Report Sixteenth Refueling Outage | |
LR-N11-0035, Refueling Outage R16 Steam Dryer Inspection Results | 1 February 2011 | Refueling Outage R16 Steam Dryer Inspection Results | |
LR-N09-0163, Submittal of Inservice Inspection Activities - 90 Day Report Fifteenth Refueling Outage | 30 July 2009 | Submittal of Inservice Inspection Activities - 90 Day Report Fifteenth Refueling Outage | |
LR-N08-0266, Submittal of Relief Request Associated with the Second Inservice Inspection (ISI) Interval | 11 December 2008 | Submittal of Relief Request Associated with the Second Inservice Inspection (ISI) Interval | Nondestructive Examination |
LR-N08-0012, Inservice Inspection Activities - 90 Day Report Fourteenth Refueling Outage | 14 February 2008 | Inservice Inspection Activities - 90 Day Report Fourteenth Refueling Outage | Weld Overlay |
LR-N07-0284, Submittal of Relief Requests Associated with the Third Inservice Inspection (ISI) Interval | 12 December 2007 | Submittal of Relief Requests Associated with the Third Inservice Inspection (ISI) Interval | VT-2 Dissimilar Metal Weld |
LR-N06-0337, Inservice Inspection Activities - 90 Day Report, Thirteenth Refueling Outage | 8 August 2006 | Inservice Inspection Activities - 90 Day Report, Thirteenth Refueling Outage | Weld Overlay Nondestructive Examination VT-2 EVT-1 Liquid penetrant Pressure Boundary Leakage Through Wall Leak |
ML032530391 | 3 September 2003 | Request for Additional Information Response - Relief Request HC-RR-B12 | EVT-1 |
ML032410065 | 21 August 2003 | Inservice Inspection Activities - 90 Day Report, Eleventh Refueling Outage | Nondestructive Examination VT-2 EVT-1 Liquid penetrant Pressure Boundary Leakage |
ML031630973 | 5 June 2003 | Inservice Inspection Program Relief Request HC-RR-A10 | Non-Destructive Examination |
ML031400574 | 9 May 2003 | Inservice Inspection Program, Revision to Relief Request HC-RR-B11, Hope Creek Generating Station | EVT-1 |
ML031070440 | 9 April 2003 | Inservice Inspection Program Relief Request Hope Creek Station | |
ML030690177 | 20 February 2003 | Inservice Inspection Program Relief Request HC-RR-F02 | |
ML021010241 | 1 April 2002 | Inservice Inspection Program Relief Request SH-RR-W01 for Salem Generating Station, Units 1 and 2, Hope Creek Station | |