ML20210U82331 January 1999Technical Evaluation Rept Pump & Valve Inservice Testing Program Braidwood Nuclear Power Station,Units 1 & 2Boric Acid
High Radiation Area
Stroke time
Weld Overlay
Power Operated Valves
Scaffolding
ML20085K46730 June 1995Technical Evaluation Rept:Evaluation of Utility Response to Suppl 1 to NRC Bulletin 90-01,Braidwood-1/2
L-94-010, Evaluation of Util Response to Suppl 1 to NRC Bulletin 90-01: Byron-1/-2, Technical Evaluation Rept31 October 1994Evaluation of Util Response to Suppl 1 to NRC Bulletin 90-01: Byron-1/-2, Technical Evaluation Rept
ML20091D17331 July 1991Auxiliary Feedwater System RISK-BASED Inspection Guide for the Byron and Braidwood Nuclear Power PlantsPacking leak
Probabilistic Risk Assessment
ML20085C08130 April 1991TER Rept on First 10-Yr Interval ISI Program Plan for Braidwood Nuclear Power Station Units 1 & 2Boric Acid
High Radiation Area
Hydrostatic
VT-2
Incorporated by reference
Scaffolding
ML20059E19724 August 1990Emergency Preparedness Exercise, Final Rept Per Insp Repts 50-454/90-16 & 50-455/90-15
ML20084T30330 June 1990Pump & Valve Inservice Testing Program,Braidwood Station, Units 1 & 2, Technical Evaluation ReptBoric Acid
Stroke time
Cold shutdown justification
Power Operated Valves
ML20058K22514 June 1990Technical Evaluation Rept,Braidwood Station Units 1 & 2 Station Blackout EvaluationSafe Shutdown
Battery sizing
ML20058K1653 April 1990Technical Evaluation Rept Byron Station Units 1 & 2 Station Blackout EvaluationSafe Shutdown
Battery sizing
ML20011D10530 September 1989Conformance to Generic Ltr 83-28,Item 2.2.1-Equipment Classification for All Other Safety-Related Components: Byron-1/-2, Technical Evaluation Rept
ML20011D10330 September 1989Conformance to Generic Ltr 83-28,Item 2.2.1-Equipment Classification for All Other Safety-Related Components: Braidwood-1/-2, Technical Evaluation Rept
ML20246B97331 March 1989Conformance to Reg Guide 1.97:Byron 1/2 & Braidwood 1/2, Technical Evaluation ReptBoric Acid
ML20070Q51531 January 1989Nuclear Power Plant Sys Sourcebook,Byron 1 & 2Safe Shutdown
Boric Acid
Ultimate heat sink
Hydrostatic
Emergency Lighting
ML20070Q50031 January 1989Nuclear Power Plant Sys Sourcebook,Braidwood 1 & 2Safe Shutdown
Boric Acid
Ultimate heat sink
Hydrostatic
Emergency Lighting
ML20244A68031 March 1988Technical Evaluation Rept for Review of Byron Nuclear Generating Station Essential Svc Water Cooling Tower Thermal Performance Test Rept
ML20042D07031 January 1988TMI Action-NUREG-0737 (II.D.1),Braidwood Units 1 & 2, Technical Evaluation ReptLoop seal
Anticipated operational occurrence
Earthquake
ML20207E20631 January 1988Technical Evaluation Rept,Tmi Action - NUREG-0737 (II.D.1), Byron Units 1 & 2Loop seal
Anticipated operational occurrence
Earthquake
ML20235M35931 August 1987Preliminary Conformance to Reg Guide 1.97:Byron Units 1 & 2 & Braidwood Units 1 & 2, Technical Evaluation ReptBoric Acid
ML20235M93030 June 1987Final Evaluation of Braidwood Station Unit 1 Tech Specs, Informal Rept
ML20215L99022 May 1987Essential Svc Water Cooling Tower Test Plan Preliminary Evaluation, Ltr Rept
ML20215H67731 March 1987Conformance to Generic Ltr 83-28,Item 2.2.2,Vendor Interface Programs (All Other Safety-Related Components), Byron Station,Units 1 & 2, Technical Evaluation Rept
ML20213H06828 February 1987Conformance to Generic Ltr 83-28,Item 2.2.2, 'Vendor Interface Programs (All Other Safety-Related Components),' Braidwood Station Units 1 & 2, Technical Evaluation Rept
ML17334B03330 November 1986Input for Ser,Beaver Valley Power Station Units 1 & 2, Braidwood Station Units 1 & 2,Byron Station Units 1 & 2, Callaway Plant Unit 1,Catawba Nuclear Station Units 1..., Reactor Trip Sys Reliability Item 4.5.2 Generic Ltr 83-28.
ML20211E96431 October 1986Rev 3 to Conformance to Generic Ltr 83-28,Item 3.1.3 & 3.2.3,Braidwood Units 1 & 2,Byron Station Units 1 & 2, Callaway Plant Unit 1,Indian Point Unit 3,Trojan Nuclear Plant & Wolf Creek Generating Station
ML20206F52130 June 1986Analysis of Allowed Outage Times at Byron Generating StationSafe Shutdown
Boric Acid
Mission time
Probabilistic Risk Assessment
ML20133G4809 October 1985Review of Licensee & Applicant Responses to NRC Generic Ltr 83-28,Item 1.2 `Post-Trip Review:Data & Info Capabilities' for Byron Station,Units 1 & 2, Technical Evaluation Rept
ML20138K98430 September 1985Conformance to Generic Ltr 83-28,Items 3.1.3 & 3.2.3, Byron Station Unit 1,Callaway Plant Unit 1,Indian Point Unit 3,Trojan Nuclear Plant & Wolf Creek Generating Station
ML20138M46226 September 1985Design Verification Audit of SPDS for Byron Generating Station Units 1 & 2
ML20137D55631 July 1985Aerial Radiological Survey of Byron Station & Surrounding Area,Apr 1985
ML20132D14524 June 1985Final Review of Byron Limiting Condition for Operation Relaxation Study,Task 1, Interim ReptProbabilistic Risk Assessment
ML20083D08530 November 1983Review of the Byron/Braidwood Units 1 and 2 Auxiliary Feedwater System Reliability Analysis
ML20112J14531 July 1983Audit of Environ Qualification of Safety-Related Electrical Equipment at Byron Units 1 & 2 & Braidwood Units 1 & 2Boric Acid
Anchor Darling
ML20065C35831 July 1982Control of Heavy Loads at Nuclear Power Plants,Byron Units 1 & 2 & Braidwood Units 1 & 2, Draft Technical Evaluation ReptSafe Shutdown
Overtravel
Control of Heavy Loads