ML20217A16922 September 1999Part 21 Rept Re Engine Sys,Inc Controllers,Manufactured Between Dec 1997 & May 1999,that May Have Questionable Soldering Workmanship.Caused by Inadequate Personnel Training.Sent Rept to All Nuclear Customers
ML20205N8341 April 1999Part 21 Rept Re Automatic Switch Co Nuclear Grade Series X206380 & X206832 Solenoid Valves Ordered Without Lubricants That Were Shipped with Std Lubrication to PECO & Tva.Affected Plants Were Notified
ML20207E93126 February 1999Part 21 Rept Re Sprague Model TE1302 Aluminum Electrolytic Capacitors with Date Code of 9322H.Caused by Aluminum Electrolytic Capacitors.Affected Capacitors Replaced
ML20199M08922 January 1999Part 21 Rept Re Failure of Square Root Converters.Caused by Failed Aluminum Electrolytic Capacitory Spargue Electric Co (Model Number TE1302 with Mfg Date Code 9322H).Sent Square Root Converters Back to Mfg,Barker Microfarads,Inc
ML20153D01918 September 1998Part 21 Rept Re Defect in Gap Conductance Analyses for co- Resident BWR Fuel.Initially Reported on 980917.Corrective Analyses Performed Demonstrating That Current Operating Limits Bounding from BOC to Cycle Exposure of 8 Gwd/MtuFuel cladding
ML20153C67717 September 1998Part 21 Rept Re Defect Relative to MCPR Operating Limits as Impacted by Gap Conductance of co-resident BWR Fuel at Facilities.Operating Limit for LaSalle Unit 2 & Quad Cities Unit 2 Will Be Revised as Listed
ML20248F35321 May 1998Part 21 Rept Re Electronic Equipment Repaired or Reworked by Integrated Resources,Inc from Approx 930101-980501.Caused by 1 Capacitor in Each Unit Being Installed W/Reverse Polarity. Policy of Second Checking All Capacitors Is Being AdoptedReverse polarity
ML20217D02822 April 1998Part 21 Rept Re Additive Constants Used in MCPR Determination for Siemens ATRIUM-9B Fuel by Core Monitoring Sys Were Found to Be non-conservative.SPC Personnel Notified All Customers w/ATRIUM-9B Lead Test AssembliesFitness for Duty
LD-97-031, Part 21 Rept Re Incorrect Nut & Washer Plate Matl for ECCS Suction Strainer Bolted Connections.Nut Plates & Washer Plates Fabricated from Incorrect Matl & Delivered to Peach Bottom Unit 3 Site.Nut & Washer Plates Never Installed30 October 1997Part 21 Rept Re Incorrect Nut & Washer Plate Matl for ECCS Suction Strainer Bolted Connections.Nut Plates & Washer Plates Fabricated from Incorrect Matl & Delivered to Peach Bottom Unit 3 Site.Nut & Washer Plates Never Installed
ML20211M6498 October 1997Addenda 1 to Part 21 Rept Re Weldments on Opposed Piston & Coltec-Pielstick Emergency stand-by Diesel gen-set lube-oil & Jacket Water Piping Sys.Revised List of Potentially Affected Utils to Include Asterisked Utils,Submitted
ML20211M9483 October 1997Supplemental Part 21 Rept Re Condition Effected Emergency Svc Water Pumps Supplied by Bw/Ip Intl Inc to Gpu Nuclear, Oyster Creek Nuclear Generation Station.No Other Nuclear Generating Stations Effected by Notification
ML20211H79130 September 1997Part 21 Rept Re Failure of Weldment Associated w/lube-oil Piping Sys on 970804 at Millstone,Unit 2.Root Cause Is Not Yet Known.Quality of Weldment Is Being Considered.Listed Util Sites Affected
ML17309A62129 September 1997Part 21 Rept Re Final Disposition of Masterflow 713 & Embeco 636 Grout Nonconformance Reported by Master Builders,Inc. Licensee Continuing to Monitor shelf-life of Masterflow 713 & Embeco 636 Grouts Produced at Rancho Cucamonga
ML20211B74624 September 1997Part 21 Rept Re Failure of Emergency Service Water Pump Due to Threaded Flange Attaching Column to Top Series Case Failure.Caused by Dissimilar Metals.Pumps in High Ion Svc Will Be Upgraded to 316 Stainless Steel Matl
ML20217J61314 July 1997Part 21 Rept Re Incomplete Defined Changes Made to Standby DG W/Emd Diesel Engines by Mfg
ML20140J19812 June 1997Part 21 Rept Re Failures of GE Type CR120AD Relays Dedicated for SR Use.Resulting High Current Through Short Circuit Caused Magnet Wire to Fuse & Produced Energetic Arc at Failure
ML20140A47627 May 1997Provides Addl Info to 970429 Part 21 Rept Re Potential safety-related Problem W/Asco HV 266000-007J Scram Solenoid Pilot Valves.Corrective Actions Also Listed
ML20148B0182 May 1997Part 21 Rept Re Failure of Plunger on Solenoid Number 1 to Return to de-actuated Position in Timely Manner When Solenoid Was de-energized.Caused by Plunger Moving While in Energized Condition.Added 'Noise' Test
ML20140G55529 April 1997Part 21 Rept Re Potential safety-related Problems W/Asco HV 266000-007J Scram Solenoid Pilot Valves (Sspv).Caused by Hardening of Core Disc in SSPV Pilot Head.Investigation Is Continuing
ML20133E8008 January 1997Deficiency Rept Re Nonconformance Related to Masterflow 713 Grout,Which Master Builders,Inc Has Supplied as Nuclear SR Product to 18 Npps.Cause Unknown.Requests That Listed Info Be Provided to Gain Insight as to Scope & Possible Cause
ML20134F5744 November 1996Part 21 Rept Re non-compliance for DG Control Sys.Licensee Revised Component Dedication Rept to Require Removal of Jumper & Require Checking Auxiliary Contact Arm Screws for Tightness.Gpu Only User Affected by Notification
ML20134D85728 October 1996Part 21 Rept Re Steam Isolation Valved Failed to Close within 3-5 Seconds Required by Ts.Caused by One Plunger from Solenoid Missed Machining Operation After Vitron Insert Pressed In.Solenoid Energized
ML20115J39822 July 1996Interim Part 21 Rept Re 3/4 Schedule 80 Pipe Furnished to Consolidated Power Supply.Investigation Revealed Only One Nuclear Customer Involved in Sale of Matl
ML20095K39121 December 1995Final Part 21 Rept 95-015 Re Bldg of Achor Darling Valves W/ Cavitation Trim.Plant Will Perform Monthly Testing of Running Loads on a Loop Valve Until ModifiedTime of Discovery
Anchor Darling
ML20086T17619 July 1995Part 21 Rept Re Potential Problem W/Type 51's & 87T Relays. Potential Problem Identified as Defective Tap Block. Recommends That Users Identified on Attachment 1 Page Verify Testing Per Instruction Listed on Encl Product Advisory Ltr
ML20083L12014 March 1995Part 21 Rept Re Model 200,227A,288A & 289A Differential Pressure Instruments Mfg w/B-fill Fluid Possibly Not Functioning If Subj to Radiation Field Greater than 1 Million rads.Long-term Evaluation in Progress
ML20078F60230 January 1995Part 21 Rept Re Possibilities of Some Nonconforming Diodes May Have Been Used in Safety Related Spare Parts Provided for S4N,D4N,T4N & 2100C
ML20078S19321 December 1994Final Part 21 Rept Re Nonconservative Assumptions of Turbine Bypass Vot in Plant Transient Analyses for Unit 2.GE Analyses Determined That Deviation Created Potential Substantial Safety HazardTime of Discovery
Feedwater Controller Failure
JAFP-94-0571, Part 21 Rept Re Spare GE Molded Case Circuit Breaker.Breaker Overcurrent Trip Failed to Perform within Specified time- Current Curve.Defective Breaker Returned to GE for Evaluation28 November 1994Part 21 Rept Re Spare GE Molded Case Circuit Breaker.Breaker Overcurrent Trip Failed to Perform within Specified time- Current Curve.Defective Breaker Returned to GE for Evaluation
ML18038A8977 September 1994Part 21 Rept Re Defect in Latching Mechanism of Potter & Brumfield Relay on C&D High Voltage Shut Down Alarm Assembly Printed Circuit Boards.Pull Test on Relay Reset Button Incorporated Into Receiving Insp Procedures
ML20072P67829 August 1994Part 21 Re Condensers for Four 25 Ton Safety Related Packaged Air Conditioner Units (Acu) for BFN Units 1 & 3. Acus Supplied by Ellis & Watts & Condensers Supplied by Itt. Condensers Returned to Itt to Rerate Shell
ML20059H77217 January 1994Part 21 Rept Re Virginia Power Notifying Fairbands Morse Via Failure Analysis Rept NESML-Q-058 of Defective Air Start Distributor cam,16104412
ML20059F2637 January 1994Part 21 Rept Re Air Start Distributor Cam Mfg by Fairbanks Morse.Mfg Suggests That Site Referenced in Encl App I Inspect Air Start Distributor Cam as Soon as Practical
ML20058H0743 December 1993Part 21 Rept Re Discovery That Current Limiting Isolation Resistors Not Located in Respective Scram Contactor Boxes as Required by Plant Design Documents.Recommends That Isolation Resistors Be Installed in Scram Contactor Separation BoxesHot Short
Safe Shutdown
ML20058G59817 November 1993Part 21 Rept Re Westronics Recorders,Model 2100C.Signal Input Transition Printed Circuit Board Assembly Redesigned to Improve Recorder Immunity to Electromagnetic Interference.List of Affected Recorders & Locations Encl
ML20059L98611 November 1993Part 21 Rept Re Deviation Wherein Fully Open Butterfly Valve Located 15 Pipe Diameters Upstream of Sensors Was Disturbing Flow Profile Enough to Cause Ultrasonic Meter to Indicate 3 to 4% Low.Customers Notified & Valve Removed
ML20056D70715 July 1993Part 21 Rept Re Reportable defect-75 PSIG Relief Check Valve 1 Npt,Emd 9521844,Kepner 416C-1-75
ML20128N62812 February 1993Updates 920929 Part 21 Rept Re Failure of Wyle Rept 30081-99 to Provide Sufficient Evidence That Eight Cited Solenoid Valve Assemblies Qualified Per Rev a to Wyle Rept 17514-1.Parts Returned to Util on 930211.Rept WithheldCommercial Grade Dedication
ML20125C7167 December 1992Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils EnclStroke time
Anchor Darling
ML20127N23425 November 1992Interim Part 21 Rept Re Defect in GE RMS-9 Trip Devices W/ Instantaneous Trip Function.Initially Reported on 921027. Util Formally Discontinued Installation of Defective Devices & Investigating Replacement of Units W/Ge
ML20127P58623 November 1992Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl
ML20116J8659 November 1992Update to 920929 Part 21 Rept Re Failure of Wyle Rept 30081-99 to Provide Sufficient Evidence That Noted Serial Numbers on Solenoid Manifold Assemblies,Mfg by Automatic Valve Co,Qualified.Util Returned Valves on 921005Commercial Grade Dedication
ML20116L60027 October 1992Part 21 Rept Documenting Event 24505 Re GE Ak Circuit breaker,RMS-9 Trip Devices W/Instantaneous Trip Adjustment. Installation of RMS-9 W/Instantaneous Function Discontinued
ML20116L5129 October 1992Part 21 Rept Re safety-related RHR Pump Motor Fan Failure Due to Lack of Weld Penetration Between Fan Blades & Discs. New Duplicate GE Motors Mfg by GE Canada,Motors & Drive Dept.New Surplus Motors Have Double Fillet Welds
ML20115C63830 September 1992Part 21 Rept Re Failure to Provide Sufficient Evidence That Eight Solenoid Manifold Valves,W/Codes GRE-001 Through GRE-008,mfg by Automatic Valve,Qualified to Wyle Rept 17514-1,Rev A.Return of Defective Valves RequestedCommercial Grade Dedication
ML20118B82930 September 1992Potential Part 21 Rept Re Lack of Evidence That Eight Solenoid Manifold Assemblies Mfg by Automatic Valve Qualified to NUREG-0588,Category I Requirements.Return of Suspect Assemblies Requested
ML20106B83524 September 1992Part 21 Rept Re Cracked Weld Found in Sample of ASTM A-500 Grade B Steel Tubing Heat T42510 from Coil 924544.Micro Analysis Indicated That Edges of Tubing Did Not Come in Contact from Weld During Mfg Process
ML20118B60822 September 1992Part 21 Rept Re Crack in Weld Seam on Wall Section of ASTM A-500 Grade B Steel Tubing Found by Tva/Bechtel.Caused by Not Enough Contact or No Contact Near Tube Outside Diameter.Mill Operators Should Be Reinstructed
ML20115B74022 September 1992Part 21 Rept Re Crack in Weld Seam of One End of Sample Taken of 4 X 4 X 1/2 ASTM-500 Grade B Tubing Supplied by Consolidated Power Supply.Appropriate Personnel Reinstructed on Importance of Weld Quality
ML20118B43911 September 1992Part 21 Rept Re Degradation in Abb Type 27N Undervoltage Relays Used in Electrical Switchgear.Recommends That Users Review Applications Requiring Exposures Greater than 1E03 Rads TID W/Time Delay Function Option