RS-22-108, Response to Request for Additional Information LaSalle County Station, Units 1 and 2 and Quad Cities Nuclear Power Station, Units 1 and 2 License Amendments Related to Fuel Storage

From kanterella
(Redirected from RS-22-108)
Jump to navigation Jump to search

Response to Request for Additional Information LaSalle County Station, Units 1 and 2 and Quad Cities Nuclear Power Station, Units 1 and 2 License Amendments Related to Fuel Storage
ML22278A149
Person / Time
Site: Quad Cities  
(DPR-029, DPR-030)
Issue date: 10/05/2022
From: Simpson P
Constellation Energy Generation
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML22278A148 List:
References
RS-22-108
Download: ML22278A149 (58)


Text

4300 Winfield Road Warrenville, IL 60555 630 657 2000 Office PROPRIETARY INFORMATION - WITHHOLD UNDER 10 CFR 2.390 contains Proprietary Information. Withhold from public disclosure under 10 CFR 2.390. When separated from Attachment 4, this document is decontrolled.

October 5, 2022 10 CFR 50.90 RS-22-108 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Quad Cities Nuclear Power Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265

Subject:

Response to Request for Additional Information RE: LaSalle County Station, Units 1 and 2 and Quad Cities Nuclear Power Station, Units 1 and 2 License Amendments Related to Fuel Storage

References:

1. Letter from P.R. Simpson (Exelon Generation Company, LLC) to U.S. NRC, "License Amendment Request Regarding New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies with Proposed Change to Technical Specifications Section 4.3.1," dated October 25, 2021 (ADAMS Accession No. ML21298A168)
2. Email from R. Kuntz (U.S. NRC) to R. Steinman (Constellation Energy Generation), "Request for Additional Information RE: LaSalle County Station, Units 1 and 2 and Quad Cities Nuclear Power Station, Units 1 and 2 License Amendments Related to Fuel Storage," dated September 12, 2022 (ADAMS Accession No. ML22256A011)

In Reference 1, Constellation Energy Generation, LLC (CEG) requested an amendment to Renewed Facility Operating License Nos. DPR-29 and DPR-30 for Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2, respectively. The proposed changes support the transition from Framatome (formerly AREVA) ATRIUM 10XM fuel to Global Nuclear Fuel - Americas, LLC (GNF-A) GNF3 fuel by allowing a different methodology to be used for the criticality safety evaluation for the spent fuel pool (SFP) and the new fuel vault (NFV).

In Reference 2, the NRC requested additional information that is needed to complete review of the proposed methodology change. Attachment 1 provides the additional information requested for QCNPS. CEG will submit a separate letter to address the LaSalle County Station aspects of Reference 2. Attachments 2 (non-proprietary) and 4 (proprietary) are vendor reports that support the additional information provided in Attachment 1. A signed affidavit from the owner of the information, GNF-A, is included as Attachment 3. The affidavit sets forth the basis on which GNF-As information may be withheld from public disclosure by the NRC and addresses

U.S. Nuclear Regulatory Commission October 5, 2022 Page 2 with specificity the considerations listed in paragraph (b)(4) of 10 CFR 2.390, "Public inspections, exemptions, requests for withholding." Accordingly, it is respectfully requested that the information in Attachment 4, which is proprietary to GNF-A be withheld from public disclosure.

CEG has reviewed the information supporting the finding of no significant hazards consideration, and the environmental consideration that were previously provided to the NRC in Reference 1. The additional information provided in this submittal does not affect the bases for concluding that the proposed license amendments do not involve a significant hazards consideration. In addition, the information provided in this submittal does not affect the bases for concluding that neither an environmental impact statement nor an environmental assessment needs to be prepared in connection with the proposed amendment.

CEG is notifying the State of Illinois of this supplement to a previous application for a change to the operating license by sending a copy of this letter and its attachments to the designated State Official in accordance with 10 CFR 50.91, "Notice for public comment; State consultation,"

paragraph (b).

There are no regulatory commitments included in this letter.

Should you have any questions concerning this letter, please contact Ms. Rebecca L. Steinman at 630-657-2831.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 5th day of October 2022.

Respectfully, Patrick R. Simpson Sr. Manager Licensing Constellation Energy Generation, LLC Attachments:

1. Response to Request for Additional Information (Non-Proprietary)
2. GEH Report 003N7421-NP, Revision 1, "Generic Criticality Safety Analysis of GE New Fuel Storage Racks for GNF3 Fuel," dated September 2022 (Non-Proprietary)
3. Global Nuclear Fuels - Americas, LLC 10 CFR 2.390 Affidavit for Attachment 4
4. GEH Report 003N7421-P, Revision 1, "Generic Criticality Safety Analysis of GE New Fuel Storage Racks for GNF3 Fuel," dated September 2022(Proprietary) cc:

Regional Administrator - NRC Region III NRC Senior Resident Inspector - Quad Cities Nuclear Power Station Illinois Emergency Management Agency - Department of Nuclear Safety

ATTACHMENT 1 RS-22-108 Response to Request for Additional Information

ATTACHMENT 1 Response to Request for Additional Information 1 of 3 REQUEST FOR ADDITIONAL INFORMATION TO SUPPORT REVIEW OF CRITICALITY SAFETY ANALYSIS THAT SUPPORT LICENSE AMENDMENT REQUESTS FOR LASALLE COUNTY STATION, UNITS 1 AND 2, AND QUAD CITIES NUCLEAR POWER STATION, UNITS 1 AND 2 DOCKET NOS. 50-373, 50-374, 50-254, AND 50-265 By applications dated June 30 and October 25, 2021 (Agencywide Document Access and Management System (ADAMS) Accession Nos. ML21183A169 and ML21298A168), Exelon Generation Company, LLC, submitted similar license amendment requests (LARs) for LaSalle County Station, Units 1 and 2 (LaSalle), and Quad Cities Nuclear Power Station, Units 1 and 2 (Quad Cities) respectively. The LaSalle LAR was supplemented by letters dated November 4, 2021 (ML21312A457) and June 17, 2022 (ML22172A175). The Quad Cities LAR was supplemented by letters dated November 3, 2021 (ML22194A086), and July 13, 2022 (ML22194A085). On February 1, 2022 (ADAMS Accession No. ML22032A333), Exelon Generation Company, LLC was renamed Constellation Energy Generation, LLC (the licensee). The proposed amendments would allow the licensee to use a new criticality safety analysis (CSA) methodology for GNF3 and legacy fuel types in the spent fuel pool. The proposed amendments would also change the CSA for the new fuel vault (NFV) to use the GESTAR II methodology for the storage of new GNF3 fuel in the NFV racks.

On August 2, 2022 (ML22214A004) the NRC issued a plan for the audit of the LaSalle and Quad Cities, as well as a similar amendment submitted by letter dated June 8, 2022 (ML22159A310) for Dresden Nuclear Power Station, Units 2 and 3. The audit was conducted to increase the NRC staffs understanding of the criticality information. The audit was conducted via virtual discussions and the use of an online portal from August 4 through September 2, 2022.

RAI-SFNB-8 Regulatory Requirements Paragraph 50.68(a) of Title 10 of the Code of Federal Regulations (10 CFR) requires each holder of a construction permit or operating license for a nuclear power reactor issued under this part or a combined license for a nuclear power reactor issued under Part 52 of this chapter, shall comply with either 10 CFR 70.24 of this chapter or the requirements in paragraph (b) of this section. The licensee has chosen to comply with 10 CFR 50.68(b).

Paragraph 50.68(b)(2) of 10 CFR states: The estimated ratio of neutron production to neutron absorption and leakage (k-effective) of the fresh fuel in the fresh fuel storage racks shall be calculated assuming the racks are loaded with fuel of the maximum fuel assembly reactivity and flooded with unborated water and must not exceed 0.95, at a 95 percent probability, 95 percent

ATTACHMENT 1 Response to Request for Additional Information 2 of 3 confidence level. This evaluation need not be performed if administrative controls and/or design features prevent such flooding or if fresh fuel storage racks are not used.

Paragraph 50.68(b)(3) of 10 CFR states: If optimum moderation of fresh fuel in the fresh fuel storage racks occurs when the racks are assumed to be loaded with fuel of the maximum fuel assembly reactivity and filled with low-density hydrogenous fluid, the k-effective corresponding to this optimum moderation must not exceed 0.98, at a 95 percent probability, 95 percent confidence level. This evaluation need not be performed if administrative controls and/or design features prevent such moderation or if fresh fuel storage racks are not used.

Background

In Section 2.3 of the LARs, the licensee states that the LaSalle and Quad Cities updated final safety analysis reports (UFSARs) will be updated as part of implementation of the amendments.

The licensee stated that these updates would include changes to reflect the proposed revisions to the NFV CSA.

By emails dated May 18 (ML22172A175) and June 13 (ML22164A785), 2022, the NRC staff requested, in part, that the licensee provide the following information for LaSalle and Quad Cities, respectively:

NFV criticality safety analysis methodology used in the analysis.

Criticality safety analysis that sets the limits for the NFVs.

Criticality safety analysis that demonstrates GNF3 meets the limits for the NFVs.

The licensees June 17 and July 13, 2022, letters provided additional information regarding the analysis performed to support the license amendment requests but did not provide the CSA methodology or the CSAs. During the regulatory audit, the NRC staff identified that information needed to support the review was included in a GNF3 fuel design specific NFV criticality safety analysis.

Request Provide the GNF3 fuel design specific NFV criticality safety analyses that would apply to LaSalle and Quad Cities. Confirm that proposed changes to the UFSARs include incorporating these CSAs (e.g., by reference).

CEG Response The fuel design specific new fuel vault (NFV) criticality safety analysis for GNF3 fuel is provided in Attachments 2 (non-proprietary version) and 4 (proprietary version). The fuel-type-specific analysis is applicable for GNF3 fuel stored in GE-designed NFV racks with cell pitches equal to or greater than those shown in Table 1-1, New Fuel Vault Rack Dimensions" of the attached reports. The installed QCNPS NFV racks are bounded by Concept 2 dimensions provided in the referenced table. The analysis demonstrates that storage of GNF3 fuel, with maximum cold, uncontrolled in-core eigenvalue (kinf) of 1.31, in the QCNPS NFV racks results in a storage rack maximum k-effective within a 95/95 confidence interval (kmax(95/95)) of less than 0.90 for dry

ATTACHMENT 1 Response to Request for Additional Information 3 of 3 normal storage conditions, and less than 0.95 for credible abnormal operation with tolerances and uncertainties considered.

The QCNPS Updated Final Safety Analysis Report (UFSAR) will be updated in accordance with 10 CFR 50.71(e) as part of implementation of the approved amendment. In response to this request for information, UFSAR Section 9.1.1.3 will be revised as shown below. Strikeout indicates proposed deletions and underlined text indicates proposed additions to the existing Section 9.1.1.3 text.

9.1.1.3 Safety Evaluation The new fuel storage racks are designed in accordance with Draft General Design Criterion 66 to prevent an accidental critical array, even in the event the vault becomes flooded. [9.1-4]

The spacing of fuel bundles in the new fuel storage vault maintains k{eff} <0.90 dry and k{eff} <0.95 flooded. [9.1-5] These conditions can be met for any GNF3 fuel lattice with kinf in the standard cold core geometry less than or equal to 1.31, which meets the licensing criteria defined by GESTAR (Reference 19). Additional details regarding the NFV criticality safety analysis for GNF3 fuel is found in 003N7421 (Reference 20).

The vault floor drain prevents flooding. A radiation monitor at the new fuel storage vault provides warning of any radiation level increase. Since the vault opens only at the top, the new fuel elements are afforded maximum protection. Grating is provided below the hatches such that, with the hatches removed, only one row of stored fuel will be exposed. Seismic design for the new fuel storage vault is described in Section 3.7.

ATRIUM 10XM assemblies can be safely stored in the Quad Cities Unit 1 and Unit 2 new fuel storage vault and meet the criteria of keff less than 0.90 for the dry condition and less than 0.95 for the fully flooded with un-borated water condition. Reference 18 provides the lattice enrichment and gadolinia loading criteria for ATRIUM 10XM assemblies to be safely stored in the Quad Cities Unit 1 and Unit 2 new fuel storage vault.

In addition, controls have been implemented to further reduce the probability of a criticality occurrence, i.e., the storage array will be in a moderation controlled area. A moderation control area limits the amount of hydrogenous material in the area. Administrative controls as generally defined in SIL 152[9] have been incorporated for the area.

ATTACHMENT 2 RS-22-108 GEH Report 003N7421-NP, Revision 1, "Generic Criticality Safety Analysis of GE New Fuel Storage Racks for GNF3 Fuel," dated September 2022 (Non-Proprietary)

GE Hitachi Nuclear Energy Copyright © 2022, GE-Hitachi Nuclear Energy Americas LLC, All Rights Reserved 003N7421-NP Revision 1 September 2022 Non-Proprietary Information Generic Criticality Safety Analysis of GE New Fuel Storage Racks for GNF3 Fuel Captured in PLM Spec. # 007N3330 R0

003N7421-NP Revision 1 Non-Proprietary Information Page 2 of 47 INFORMATION NOTICE Proprietary information of GNF has been removed from this non-proprietary version of 003N7421-P, Revision 1. The information removed was contained between opening double brackets ( (( ) and closing double brackets ( )) ).

IMPORTANT NOTICE REGARDING CONTENTS OF THIS REPORT Please Read Carefully The design, engineering, and other information contained in this document are furnished in accordance with the contract between Exelon and GNF, and nothing contained in this document shall be construed as changing the contract. The use of this information by anyone other than Exelon or for any purpose other than that for which it is furnished by GNF is not authorized; and with respect to any unauthorized use, GNF makes no representation or warranty, express or implied, and assumes no liability as to the completeness, accuracy, or usefulness of the information contained in this document, or that its use may not infringe privately owned rights.

003N7421-NP Revision 1 Non-Proprietary Information Page 3 of 47 REVISION

SUMMARY

Rev.

Section Modified Revision Description 0

Initial Release 1

Multiple Revised Table A-3 for CR-27347.

Minor administrative editorial changes.

003N7421-NP Revision 1 Non-Proprietary Information Page 4 of 47 TABLE OF CONTENTS

1.0 INTRODUCTION

............................................................................................................... 10 2.0 REQUIREMENTS.............................................................................................................. 11 3.0 METHOD OF ANALYSIS................................................................................................. 12 3.1 CROSS SECTIONS............................................................................................................... 12 3.2 GEOMETRY TREATMENT................................................................................................ 12 3.3 VALIDATION AND COMPUTATIONAL BASIS.............................................................. 13 3.4 IN-CORE K METHODOLOGY.......................................................................................... 14 3.5 DEFINITIONS....................................................................................................................... 15 3.6 DESIGN METHOD AND CONSERVATISMS................................................................... 15 4.0 FUEL DESIGN BASIS....................................................................................................... 17 4.1 GNF3 FUEL DESCRIPTION................................................................................................ 17 4.2 FUEL MODEL DESCRIPTION............................................................................................ 19 5.0 CRITICALITY ANALYSIS OF NEW FUEL VAULT..................................................... 21

5.1 DESCRIPTION

OF NEW FUEL VAULT STORAGE RACKS.......................................... 21 5.2 NEW FUEL VAULT STORAGE RACK MODELS............................................................ 21 5.3 FUEL RACK SELECTION................................................................................................... 24 5.4

(( ))....................................................................... 24 5.5 DESIGN BASIS LATTICE SELECTION............................................................................ 25 5.6 NORMAL CONFIGURATION ANALYSIS........................................................................ 26 5.6.1 Analytic Models..................................................................................................... 26 5.6.2 Results-Dry Conditions......................................................................................... 27 5.6.3 Results-Flooded Conditions.................................................................................. 28 5.7 ACCIDENT/ABNORMAL CONFIGURATION ANALYSIS............................................. 28 5.7.1 Analytic Models..................................................................................................... 28 5.7.2 Results.................................................................................................................... 30 5.8 TOLERANCE ANALYSIS................................................................................................... 32 5.8.1 Analytic Models..................................................................................................... 32 5.8.2 Results-Dry Conditions......................................................................................... 33 5.8.3 Results-Flooded Conditions.................................................................................. 33 5.9 UNCERTAINTY VALUES.................................................................................................. 34 5.10 MAXIMUM REACTIVITY.................................................................................................. 36

6.0 CONCLUSION

S................................................................................................................. 37

7.0 REFERENCES

.................................................................................................................... 38

003N7421-NP Revision 1 Non-Proprietary Information Page 5 of 47 APPENDIX A - MCNP-05P CODE VALIDATION................................................................... 39

003N7421-NP Revision 1 Non-Proprietary Information Page 6 of 47 List of Tables Table 1-1: New Fuel Vault Rack Dimensions.............................................................................. 10 Table 1-2: Summary Kmax(95/95) Result.......................................................................................... 10 Table 3-1: Summary of the Critical Benchmark Experiments...................................................... 13 Table 3-2: Area of Applicability Covered by Code Validation.................................................... 14 Table 4-1: Lattice Dimensions...................................................................................................... 18 Table 4-2: Cell Dimensions.......................................................................................................... 18 Table 4-3: Channel Dimensions.................................................................................................... 19 Table 5-1: GE NFV Rack Features............................................................................................... 21 Table 5-2: GE NFV Rack Element Dimensions and Drawing Specified Tolerances................... 23 Table 5-3: Rack Efficiency Comparison for Concept 2 and Concept 3 Rack Designs................ 24 Table 5-4: (( ))............................................................................... 25 Table 5-5: Fuel Parameters Studied in NFV-Full Loading, Dry................................................. 25 Table 5-6: Fuel Parameters Studied in NFV-Checkerboard Loading, Dry................................. 26 Table 5-7: Normal Configuration In-Rack K Results-Full Loading, Dry Air............................ 27 Table 5-8: Normal Configuration In-Rack K Results-Checkerboard Loading, Dry Air............ 28 Table 5-9: Normal Configuration In-Rack K Results-Full Loading, Flooded........................... 28 Table 5-10: Abnormal Configuration In-Rack K Results-Full Loading.................................... 31 Table 5-11: Abnormal Configuration In-Rack K Results-Checkerboard Loading.................... 31 Table 5-12: Tolerance Study In-Rack K Results-Full Loading, Dry......................................... 33 Table 5-13: Tolerance Study In-Rack K Results-Full Loading, Flooded.................................. 34 Table 5-14: Uncertainty K Values-Full Loading, Dry............................................................... 35 Table 5-15: Uncertainty K Values-Full Loading, Flooded........................................................ 35 Table 5-16: Uncertainty K Values-Checkerboard Loading, Dry............................................... 35 Table 5-17: Uncertainty K Values-Checkerboard Loading, Flooded....................................... 35 Table 5-18: NFV Rack Results Summary-Full Loading, Dry..................................................... 36 Table 5-19: NFV Rack Results Summary-Full Loading, Flooded.............................................. 36 Table 5-20: NFV Rack Results Summary-Checkerboard Loading, Dry..................................... 36 Table 5-21: NFV Rack Results Summary-Checkerboard Loading, Optimum Moderation........ 36 Table A-1: MCNP-05P Benchmark Calculation Results.............................................................. 39 Table A-2: Trending Parameters................................................................................................... 43 Table A-3: Trending Results Summary........................................................................................ 44 Table A-4: Bias and Bias Uncertainty for MCNP-05P with ENDF/B-VII.................................. 47

003N7421-NP Revision 1 Non-Proprietary Information Page 7 of 47 Table A-5: Recommended Bias and Bias Uncertainty................................................................. 47

003N7421-NP Revision 1 Non-Proprietary Information Page 8 of 47 LIST OF FIGURES Figure 4-1: GNF3 Lattice Configuration...................................................................................... 17 Figure 4-2: Channel 1/8 Cross Sections......................................................................................... 19 Figure 4-3: GNF3 Lattice in MCNP-05P...................................................................................... 20 Figure 5-1: Concept 2 GE NFV Storage Rack Element (X-Y Plane)........................................... 22 Figure 5-2: Concept 3 NFV Storage Rack Element (X-Y Plane)................................................. 22 Figure 5-3: New Fuel Vault Layout and Dimensions (Y-Z direction)......................................... 23 Figure 5-4: New Fuel Vault Layout and Dimensions (Y-X direction)......................................... 24 Figure 5-5: Checkerboard NFV Loading Pattern.......................................................................... 27 Figure 5-6: Optimum Moderation Results - Keff vs Percent Water Moderation.......................... 32 Figure A-1: Normality Test of Knorm Results................................................................................ 45

003N7421-NP Revision 1 Non-Proprietary Information Page 9 of 47 ACRONYMS Acronym Explanation AOA Area of Applicability BOL Beginning of Life BWR Boiling Water Reactor CFR Code of Federal Regulations EALF Energy of the Average Lethargy Causing Fission GDC General Design Criteria GEH GE Hitachi GNF Global Nuclear Fuel H/U Hydrogen to Uranium Ratio H/X Hydrogen to Fissile Material Ration IN Information Notice MOX Mixed Oxide NFV New Fuel Vault SIL Service Information Letter SS Stainless Steel

003N7421-NP Revision 1 Non-Proprietary Information Page 10 of 47

1.0 INTRODUCTION

This report describes the criticality analysis and results for a generic New Fuel Vault (NFV) for storage of 10x10 GNF3 fuel bundles. It includes sufficient detail on the methodology and analytical models utilized in the criticality analysis to verify that the storage rack systems have been accurately and conservatively represented. This report is intended to conservatively bound all existing plants with cell pitches equal to our greater than those shown in Table 1-1.

Table 1-1: New Fuel Vault Rack Dimensions GE Rack Type Cell Pitch (inches)

Concept 2: Aluminum I-beams

(( ))x10.5 Concept 3: Three tier aluminum castings

(( ))

The NFV racks are analyzed using the MCNP-05P Monte Carlo neutron transport program with the ENDF/B-VII nuclear cross section libraries and the infinite multiplication factor (k) criterion methodology. A maximum cold, uncontrolled peak in-core k of 1.31 as defined by the lattice physics code TGBLA06 is specified as the rack design limit for GNF3 fuel in the NFV racks.

This report covers both Service Information Letter (SIL) 152 (1) compliant and non-compliant plants. For non-compliant plants, an optimum moderation study is required in the criticality analysis. As a fully loaded rack under optimum moderation conditions does not meet regulatory reactivity limits, an alternate storage configuration must be used for non-compliant plants. As a result, the following two configurations were analyzed:

1.

Fully loaded assuming SIL 152 compliance

2.

One fuel bundle out of three in either linear direction checkerboard with consideration given to optimum moderation conditions Both analyses resulted in a storage rack maximum k-effective within a 95/95 confidence interval (Kmax(95/95)) less than 0.90 for dry normal storage conditions, and less than 0.95 for credible abnormal operation with tolerances and uncertainties taken into account, as demonstrated in Table 1-2. If a plant is not SIL 152 compliant, a checkerboard array must be employed where only one out of every three storage locations in either linear direction contains a fuel bundle.

Table 1-2: Summary Kmax(95/95) Result Configuration Peak in-core K Kmax(95/5) for Abnormal Operation Full loading (assuming SIL 152 compliance) 1.31 0.93919 Checkerboard loading 1.31 0.93152

003N7421-NP Revision 1 Non-Proprietary Information Page 11 of 47 2.0 REQUIREMENTS Title 10 of the Code of Federal Regulations (CFR) Part 50 defines the requirements for the prevention of criticality in fuel storage and handling at Nuclear Power Plants. 10 CFR 50.68 (2) details specifically that the storage rack eigenvalue for both new and spent fuel storage racks must be demonstrated to be 0.95 for normal and credible abnormal operation with tolerances and computational uncertainties taken into account. For cases where optimum moderation is a credible event for the storage of fresh fuel (i.e. non-compliant with SIL 152), the Kmax(95/95) corresponding to the optimum moderation condition must not exceed 0.98. The limit of 0.95 is conservatively assumed for all abnormal cases in this study. Reference (3) outlines the standards that must be met for these analyses. These requirements are supplemented by General Design Criterion (GDC) 62 (4) and Information Notice (IN) 2011-03 (5). All necessary requirements are met in this analysis.

003N7421-NP Revision 1 Non-Proprietary Information Page 12 of 47 3.0 METHOD OF ANALYSIS In this evaluation, in-core k values and exposure dependent, pin-by-pin isotopic specifications are generated using the GEH/GNF (Global Nuclear Fuel) lattice physics production code TGBLA06. TGBLA06 solves two-dimensional (2D) diffusion equations with diffusion parameters corrected by transport theory to provide system multiplication factors and perform burnup calculations.

The fuel storage criticality calculations are then performed using MCNP-05P, the GEH/GNF proprietary version of the Los Alamos National Laboratory code MCNP5 (6). MCNP-05P is a Monte Carlo program for solving the linear neutron transport equation for a fixed source or an eigenvalue problem. The code implements the Monte Carlo process for neutron, photon, electron, or coupled transport involving all these particles, and can compute the eigenvalue for neutron-multiplying systems. For the present application, only neutron transport was considered.

3.1 CROSS SECTIONS TGBLA06 uses ENDF/B-V cross-section data to perform coarse-mesh, broad-group, diffusion theory calculations. It includes thermal neutron scattering with hydrogen using an S(,) light water thermal scattering kernel.

MCNP-05P uses point-wise (i.e., continuous) cross section data, and all reactions in a given cross section evaluation (e.g., ENDF/B-VII.0) are considered. For the present work, thermal neutron scattering with hydrogen was described using an S(,) light water thermal scattering kernel. The cross section tables include all details of the ENDF representations for neutron data.

The code requires that all the cross sections be given on a single union energy grid suitable for linear interpolation; however, the cross section energy grid varies from isotope to isotope. The libraries include very little data thinning and utilize resonance integral reconstruction error tolerances of 0.001%.

3.2 GEOMETRY TREATMENT TGBLA06 is a 2D lattice design computer program for Boiling Water Reactor (BWR) fuel bundle analysis. It assumes that a lattice is uniform and infinite along the axial direction and that the lattice geometry and material are reflecting with respect to the lattice boundary along the transverse directions.

MCNP-05P implements a robust geometry representation that can correctly model complex components in three-dimensions. An arbitrary three-dimensional (3D) configuration is treated as geometric cells bounded by first and second-degree surfaces and some special fourth-degree elliptical tori. The cells are described in a Cartesian coordinate system and are defined by the intersections, unions and complements of the regions bounded by the surfaces. Surfaces are defined by supplying coefficients to the analytic surface equations or, for certain types of surfaces, known points on the surfaces. Rather than combining several pre-defined geometrical bodies in a combinatorial geometry scheme, MCNP-05P has the flexibility of defining geometrical shapes from all the first and second-degree surfaces of analytical geometry and elliptical tori and then combining them with Boolean operators. The code performs extensive checking for geometry errors and provides a plotting feature for examining the geometry and material assignments.

003N7421-NP Revision 1 Non-Proprietary Information Page 13 of 47 3.3 VALIDATION AND COMPUTATIONAL BASIS MCNP-05P has been compared to (( )) critical experiments for validation purposes using ENDF/B-VII.0 nuclear cross-section data. The experiments cover a number of moderator-to-fuel ratios and poison materials that represent material and geometric properties similar to that of a BWR fuel lattice both in and out of fuel racks. The critical experiments to which MCNP-05P has been compared are provided in Table 3-1. All are either low-enriched UO2 or Mixed Oxide (MOX) pin lattice in water experiments. The Area of Applicability (AOA) considered covered by this validation is listed in Table 3-2, along with the parameters which characterize the NFV rack system for comparison. The critical experiment modeling results, along with the calculation of the associated bias and bias uncertainty terms at the 95/95 confidence level using NUREG-6698 guidance, are provided in Appendix A (7). The study concluded that the appropriate bias to apply to systems covered by this AOA is (( )), and the appropriate uncertainty of that bias is (( )).

Table 3-1: Summary of the Critical Benchmark Experiments

((

))

003N7421-NP Revision 1 Non-Proprietary Information Page 14 of 47 Table 3-2: Area of Applicability Covered by Code Validation Parameters Validation Area of Applicability New Fuel Rack Characteristics Fissionable Material Uranium, Plutonium, Actinides Uranium, Actinides Chemical Form UO2, MOX UO2, MOX Enrichment (wt% U-235) wt% U-235 4.9 2.8 wt% U-235 4.9 Enrichment (wt% Pu-239) wt% Pu-239 5.3 wt% Pu-239 4.9 Physical Form Solid Compound Solid Compound Temperature

~20oC up to 100 oC 4-20oC Moderator (in fuel region)

H2O H2O Physical Form Solution Solution Temperature

~20oC up to 100 oC 4-20oC Reflector (in fuel region)

H2O H2O Physical Form Solution Solution Temperature

~20oC up to 100 oC 4-20oC Absorbers None/Boron/Gadolinium/

Stainless Steel/Copper Gadolinium/

Fission Products Neutron Energy Spectrum Thermal Thermal Energy of Average Lethargy Causing Fission (MeV) 6.8E 8.6 E-7 (Limiting In-rack) 2.1E-07 Table 3-2 demonstrates that the AOA of this validation encompasses the majority of storage characteristics of the NFV.

An additional uncertainty is also added to the fuel rack studies related to eigenvalue calculations performed using TGBLA06. A bias of (( )) and the 95%/95% tolerance level ((

)). The uncertainty is applied to the fuel racks Kmax(95/95) value to cover uncertainty in the assignment of in-core k values.

3.4 IN-CORE K METHODOLOGY The design of the fuel storage racks provides for a subcritical k for both normal and credible abnormal storage conditions. In all cases, the storage rack k must be 0.95 (3). To demonstrate compliance with this limit, the in-core k method is utilized.

The in-core k criterion method relies on a well-characterized relationship between infinite lattice k (in-core) for a given fuel design and a specific fuel storage rack k (in-rack) containing that fuel. The use of an infinite lattice k criterion for demonstrating compliance to fuel storage criticality criteria has been used for all GE-supplied racks, including those in NFV storage.

The analysis performed to calculate the lattice k to confirm compliance with the above criterion uses the NRC-approved lattice physics methods encoded into the TGBLA06 Engineering

003N7421-NP Revision 1 Non-Proprietary Information Page 15 of 47 Computer Project. One of the outputs of the TGBLA06 solution is the lattice k of a specific nuclear design for a given set of input state parameters (void fraction, control state, fuel temperature, etc.).

Compliance of GNF3 fuel with specified k limits will be confirmed for each new lattice as part of the bundle design process. The process for validating that specific assembly designs are acceptable for storage in the GE NFV racks is to compare peak in-core reactivity of the bundle to the in-core reactivity limit.

3.5 DEFINITIONS Fuel Assembly - A complete fuel unit consisting of a basic fuel rod structure that may include large central water rods. Several shorter rods may be included in the assembly. These are called part length rods. A fuel assembly includes the fuel channel.

Gadolinia - The compound Gd2O3. The gadolinia content in integral burnable absorber fuel rods is usually expressed in weight percentage gadolinia.

Lattice - An axial zone of a fuel assembly within which the axial nuclear characteristics of the individual rods are unchanged.

BASE Lattice - An axial zone of a GNF3 fuel assembly located in the bottom third of the bundle within which all possible fuel rod locations ((( ))) are occupied.

MID Lattice - ((

))

VAN Lattice - An axial zone of a GNF3 fuel assembly located in the top third of the bundle within which a number of possible fuel rod locations ((( ))) are unoccupied and ((

)).

Rack Efficiency - The ratio of in-rack k to its associated lattice nominal in-core k at a given exposure statepoint. This value allows for a straightforward comparison of a racks criticality response to varying lattice designs within a particular fuel product line. A lower rack efficiency implies increased reactivity suppression capability relative to an alternate design with a higher rack efficiency.

Design Basis Lattice - The lattice geometry, exposure history, and corresponding fuel isotopics for a fuel product line that result in the highest rack efficiency in a sensitivity study of reasonable fuel parameters at the desired in-core reactivity. This lattice is used for all normal, abnormal, and tolerance evaluations in the fuel rack analysis.

3.6 DESIGN METHOD AND CONSERVATISMS The NFV storage rack criticality calculations are performed with the following design methods and conservatisms to ensure the true system reactivity is always less than the calculated reactivity:

((

))

003N7421-NP Revision 1 Non-Proprietary Information Page 16 of 47 No credit is taken for the natural blanket ((

)).

Design basis lattices with in-core k values greater than the proposed 1.31 in-core k limit are used for all criticality analyses.

((

))

Neutron absorption in minor bundle components is neglected (e.g. spacer grids).

These structures act as neutron absorbers, neglecting them yields a higher calculated system reactivity, and therefore a more conservative result.

((

))

The storage system is modeled with periodic boundary conditions ((

))

((

))

003N7421-NP Revision 1 Non-Proprietary Information Page 17 of 47 4.0 FUEL DESIGN BASIS Criticality safety analyses to determine storage system reactivity are performed using the GNF3 fuel design. The most reactive lattice for each fuel storage configuration will then be evaluated in the GE NFV design.

4.1 GNF3 FUEL DESCRIPTION The GNF3 fuel lattice configuration is a 10x10 fuel rod array, ((

)), as shown in Figure 4-1 with corresponding dimensions in Table 4-1 and Table 4-2. Figure 4-1 also demonstrates the part-length rod locations. Fuel channel dimensions are provided in Figure 4-2 and Table 4-3. ((

))

((

))

Figure 4-1: GNF3 Lattice Configuration

003N7421-NP Revision 1 Non-Proprietary Information Page 18 of 47 Table 4-1: Lattice Dimensions Item Dimension mm in Channel

((

Fuel Rod Pellet

))

((

))

Bundle Lattice Rod-to-rod pitch Rod-to-rod gap Edge rod-to-channel gap M

N O

12.95 2.69 3.695 0.510 0.106 0.145

((

))

Table 4-2: Cell Dimensions Lattice Type Channel Name 1/2 Wide Gap, Q 1/2 Narrow Gap, R Control Blade Pitch, S mm in mm in mm in

((

))

003N7421-NP Revision 1 Non-Proprietary Information Page 19 of 47

((

))

Figure 4-2: Channel 1/8 Cross Sections Table 4-3: Channel Dimensions Channel Name 83AV 93AV Channel Section zone 1 zone 2 zone 1 zone 2 Dimension mm in mm in mm in mm in

((

))

((

))

4.2 FUEL MODEL DESCRIPTION The fuel models considered include 3D geometric modeling of all fuel material, cladding, water rods, and channels. ((

)) Neutron absorption in

003N7421-NP Revision 1 Non-Proprietary Information Page 20 of 47 minor structural members is also neglected (i.e., spacer grids are ignored). ((

)) An example of a GNF3 MID lattice model in MCNP-05P is depicted in Figure 4-3.

((

))

Figure 4-3: GNF3 Lattice in MCNP-05P The fuel loadings considered for each lattice span a range of average enrichments, number of gadolinia rods, gadolinia concentration, and void histories considered to be reasonably representative of any GNF3 fuel design. Each lattice type is analyzed at an exposure of 0 GWd/ST. The lattice type and that results in the worst-case rack efficiency for an in-core k greater than the proposed limit is then used to define the design basis lattice. This lattice is assumed to be stored in every location in the rack being analyzed. Details on the determination of the design basis lattice using the process outlined above are presented in Section 5.3.

003N7421-NP Revision 1 Non-Proprietary Information Page 21 of 47 5.0 CRITICALITY ANALYSIS OF NEW FUEL VAULT

5.1 DESCRIPTION

OF NEW FUEL VAULT STORAGE RACKS This report analyzes a NFV containing GE low-density fuel storage racks with the dimensions in Table 5-1. There are two types of NFV racks designed by GE, which will be referred to as Concept 2 and Concept 3. Models were created for both rack designs to demonstrate the most reactive rack type. Both GE NFV racks have ten positions for channeled or unchanneled fuel assemblies in a rack. The number of racks can vary from plant to plant. Thus a set of 10 racks was assumed with periodic boundary conditions to simulate an infinite number of racks in the ((

)). The Concept 2 racks maintain the fuel in geometrically safe locations by I-beam shaped aluminum structural guides. The fuel assemblies are introduced to the storage rack through the top and are fully supported at the bottom. In Concept 3, the fuel bundles are supported by three tier aluminum castings ((

)). A description of the rack models used is found in Section 5.2.

Table 5-1: GE NFV Rack Features 5.2 NEW FUEL VAULT STORAGE RACK MODELS Three-dimensional models have been defined to conservatively describe the NFV storage systems in MCNP-05P. A drawing (not to scale) of a Concept 2 storage rack element is provided in Figure 5-1, with dimensions and tolerances presented in Table 5-2. Figure 5-2 shows the rack element for Concept 3, with dimensions and tolerances presented in Table 5-2. Both elements were used to populate a 10x10 rack array. An image (not to scale) of the entire fuel vault in the Y - Z direction is provided in Figure 5-3. An image of the Y-X direction is provided in Figure 5-4. A sensitivity study was performed ((

)). This analysis investigates two different rack loadings:

1. Fully loaded assuming SIL-152 compliance
2. One in three in either linear direction checkerboard array with consideration given to optimum moderation conditions Construction Cell Pitch inches cm Concept 2 Aluminum I-beams

(( )) x 10.5

(( )) x 26.67 Concept 3 Three tier aluminum castings

((

))

003N7421-NP Revision 1 Non-Proprietary Information Page 22 of 47

((

))

Figure 5-1: Concept 2 GE NFV Storage Rack Element (X-Y Plane)

((

))

Figure 5-2: Concept 3 NFV Storage Rack Element (X-Y Plane)

003N7421-NP Revision 1 Non-Proprietary Information Page 23 of 47 Table 5-2: GE NFV Rack Element Dimensions and Drawing Specified Tolerances Tolerances Nominal Plus Minus (inch)

(inch)

(inch)

Concept 2 Short Inside Width

((

Concept 2 Long Inside Width Concept 2 Channel Lip Width Concept 2 Channel Half Thickness Concept 2 Channel Thickness Concept 2 Intra-Row Pitch Concept 2 Inter-Row Pitch

))

((

))

Figure 5-3: New Fuel Vault Layout and Dimensions (Y-Z direction)

003N7421-NP Revision 1 Non-Proprietary Information Page 24 of 47

((

))

Figure 5-4: New Fuel Vault Layout and Dimensions (Y-X direction) 5.3 FUEL RACK SELECTION A comparison study was performed to determine the highest rack efficiency and thus the most limiting rack design between Concept 2 and Concept 3. The same fuel bundle lattice was used in both cases, under dry conditions in the full loading pattern. As shown in Table 5-3, Concept 2 has the highest rack efficiency. The Concept 2 rack design was used for the rest of this analysis.

Table 5-3: Rack Efficiency Comparison for Concept 2 and Concept 3 Rack Designs Rack Concept In-Core k In-Rack k Error (1)

Rack Efficiency 2

((

0.69291

((

3

))

0.66775

))

5.4

(( ))

((

))

003N7421-NP Revision 1 Non-Proprietary Information Page 25 of 47 Table 5-4: (( ))

((

))

5.5 DESIGN BASIS LATTICE SELECTION Table 5-5 and Table 5-6 define the lattice designs and loading patterns that were explicitly studied in the Concept 2 NFV in order to determine the design basis lattice. The different lattice types and the effects of varying average enrichment coupled with gadolinia concentration were investigated. This study demonstrates that, in general, ((

)).

This meets expectations, as Beginning of Life (BOL) fuel does not experience the spectral shift associated with plutonium build-up in spent fuel, and therefore the selection of a design basis lattice is of less significance than in spent fuel rack studies. Cases 2 and 7 demonstrated the highest rack efficiencies in their given configurations, as shown in Table 5-5 and Table 5-6. Case 2 will be used to define all bundles in the remaining NFV analyses in the full loading pattern, while Case 7 will be used to define all bundles in the remaining NFV analyses in the checkerboard loading pattern.

Table 5-5: Fuel Parameters Studied in NFV-Full Loading, Dry Case Number Lattice Type Average Lattice Enrichment (U-235 wt%)

Number of Gad Rods Gad Enrichment (Gd wt%)

TGBLA06 Defined In-Core k MCNP-05P Defined In-Rack k Rack Efficiency 1

((

0.69131

((

2 0.69291 3

0.68900 4

0.65366 5

0.65043 6

))

0.65853

))

003N7421-NP Revision 1 Non-Proprietary Information Page 26 of 47 Table 5-6: Fuel Parameters Studied in NFV-Checkerboard Loading, Dry Case Number Lattice Type Average Lattice Enrichmen t (U-235 wt%)

Number of Gad Rods Gad Enrichm ent (Gd wt%)

TGBLA06 Defined In-Core k MCNP-05P Defined In-Rack k

Rack Efficiency 7

((

0.57970

((

8 0.57979 9

0.57024 10 0.55896 11 0.55278 12

))

0.55494

))

5.6 NORMAL CONFIGURATION ANALYSIS 5.6.1 Analytic Models The most reactive normal configuration was determined by studying the reactivity impact of the following credible normal scenarios:

  • Storage of non-channeled assemblies
  • Eccentric loadings o ((

o o

))

  • Bundle Rotation o ((

o

))

All of the above normal configurations were studied for the full loading pattern. In the checkerboard array (Figure 5-5), only the unchanneled and channeled cases were studied, ((

)). The normal conditions examined for each fuel loading pattern were studied in both dry and flooded conditions, (( )) (see Figure 5-3) (( )).

003N7421-NP Revision 1 Non-Proprietary Information Page 27 of 47

((

))

Figure 5-5: Checkerboard NFV Loading Pattern 5.6.2 Results-Dry Conditions The results of the normal configuration studies in dry storage are provided in Table 5-7 for the full loading, and Table 5-8 for the checkerboard loading. This information demonstrates that the removal of the channels from the storage assemblies increases the system reactivity over the nominal, centered, channeled case by a statistically significant amount under normal (dry) conditions. Due to this increased reactivity effect, all eccentric, abnormal and tolerance studies were performed with unchanneled fuel for dry conditions. The case with the highest in-rack reactivity was chosen as the design basis case for each loading pattern. The in-rack k associated with the unchanneled (( )) bundles is hereafter referred to as KNormal for the full loading under dry conditions and the in-rack k associated with unchanneled assemblies is hereafter referred to as KNormal for the checkerboard loading under dry conditions.

Table 5-7: Normal Configuration In-Rack K Results-Full Loading, Dry Air Term Configuration In-Rack k

Error (1)

K Base Nominal - Centered, Channeled 0.69291

((

KN1 Non-Channeled Assemblies 0.70459 0.01168 KN2A

((

0.70435

-0.00024 KN2B 0.70381

-0.00078 KN2C 0.70403

-0.00056 KN3A

))

0.70465 0.00006 KN3B Normal- (( ))

0.70471

))

0.00012

003N7421-NP Revision 1 Non-Proprietary Information Page 28 of 47 Table 5-8: Normal Configuration In-Rack K Results-Checkerboard Loading, Dry Air Term Configuration In-Rack k

Error (1)

K Base Nominal - Centered, Channeled, (( ))

0.57970

((

KN1 Non-Channeled Assemblies 0.58422

))

0.00452 5.6.3 Results-Flooded Conditions The results of the flooded condition study for the full loading is provided in Table 5-9. This information demonstrates that the channeled fuel is more reactive than unchanneled fuel under flooded conditions. All subsequent eccentric, abnormal and tolerance studies under flooded conditions were performed with channeled fuel. The case with the highest in-rack reactivity was chosen as the design basis case for the full loading flooded configuration.

The in-rack k associated with the channeled (( )) is hereafter referred to as KNormal for the flooded full loading configuration.

Table 5-9: Normal Configuration In-Rack K Results-Full Loading, Flooded Term Configuration In-Rack k

Error (1)

K K

Uncertainty (2)+

Base Nominal - Centered, Channeled, (( ))

0.91722

((

((

KN1 Non-Channeled Assemblies 0.91240

-0.00482 KN2A

(( ))

0.91641

-0.00081 KN2B Normal-((

))

0.92420 0.00698 KN2C

((

0.89595

-0.02127 KN3A 0.91742 0.00020 KN3B

))

0.91733

))

0.00011

))

  • Largest positive reactivity increase from nominal case for each term is included in roll-up of KBias

+ (( ))

5.7 ACCIDENT/ABNORMAL CONFIGURATION ANALYSIS 5.7.1 Analytic Models The following abnormal configurations of the NFV were considered for credible accident scenarios.

  • Water Flooding The consequences of this would be different for the two unique rack loadings, as specified below:
  • Full Loading with SIL-152 Compliance Compliance with SIL-152 obviates the requirement to perform an optimum

003N7421-NP Revision 1 Non-Proprietary Information Page 29 of 47 moderation study in the new fuel vault. However, flooding of the vault with full density water is still considered a credible scenario. As such, the NFV with a full loading of fuel is analyzed flooded with unborated water. Water densities corresponding to 4 and 20oC were studied. The high temperature flooding of the new fuel vault is considered two abnormal events (flooding of the vault and increased temperature of the flood water), and as such was not analyzed, per the double contingency principle.

  • Checkerboard Array with Optimum Moderation If a plant is not SIL-152 compliant, it is necessary to consider the system with optimum moderation throughout the vault cavity (i.e. all volumes marked air in Figure 5-3). The peak reactivity as a function of water density is identified in this study and reported as a bias in the final statistical roll-up.

The following abnormal configurations are considered bounded or non-credible:

  • Abnormal Assembly Location The consequences of this would be different for the two unique rack loadings, as specified below:
  • Full Loading No location within the rack array or next to rack is available to place additional fuel.

Thus, the abnormal assembly location is not credible for the full-loading condition.

  • Checkerboard Array Per the double contingency principle, it is not considered credible to have two single accident scenarios simultaneously (NFV at optimum moderation and a misplaced fuel assembly). The increase in reactivity introduced by optimum moderation bounds the potential increase in reactivity for the abnormal assembly location scenario. As these scenarios do not have the same initiator, it is not considered credible for both events to occur simultaneously. Therefore, it is only necessary to model the bounding condition (optimum moderation).
  • Dropped Assembly Per the double contingency principle, it is not considered credible to have two single accident scenarios simultaneously (NFV at optimum moderation or flooded conditions and a dropped fuel assembly). The increase in reactivity introduced by optimum moderation or flooding bounds the potential increase in reactivity for a dropped fuel assembly scenario. As these scenarios do not have the same initiator, it is not considered credible for both events to occur simultaneously. Therefore, it is only necessary to model the bounding condition (optimum moderation or flooding).

003N7421-NP Revision 1 Non-Proprietary Information Page 30 of 47

  • Rack Sliding In either fuel loading configuration, the racks are modeled infinitely in the y-direction with no inter-module water gaps. This essentially assumes all racks are close-fitting and bounds possible reactivity effects of rack sliding.
  • Damaged Fuel Assembly The dropped/damaged fuel scenario ((

)) Per the double contingency principle, it is not considered credible to have two single accident scenarios simultaneously (NFV at optimum moderation or flooded conditions and a damaged fuel assembly). The increase in reactivity introduced by optimum moderation or flooding bounds the potential increase in reactivity for a damaged fuel assembly scenario. As these scenarios do not have the same initiator, it is not considered credible for both events to occur simultaneously. Therefore, it is only necessary to model the bounding condition (optimum moderation or flooding).

5.7.2 Results The results of the abnormal studies are provided in Table 5-10 for the full loading and Table 5-11 for the checkerboard array. The K term for the perturbed temperature case in the full loading flooded condition represents the difference in system reactivity from the nominal temperature flooded condition detailed in Section 5.6.3. The K term for the damaged fuel case represents the difference in system reactivity from the normal dry condition, unchanneled, as detailed in Section 5.6.2. The K term for the optimum moderation cases in the checkerboard loading represents the difference in system reactivity from the corresponding (un)channeled case in Section 5.6.2.The total contribution from these independent conditions to the maximum Kmax(95/95) of each NFV rack loading is found using Equation (5-1). In this equation, a KBi value must be both positive and the largest for its respective term to be considered.

K=

(5-1)

003N7421-NP Revision 1 Non-Proprietary Information Page 31 of 47 Table 5-10: Abnormal Configuration In-Rack K Results-Full Loading Term Configuration In-Rack k

Error (1)

K K

Uncertainty (2)+

KB1 Flood - Full Density Water (4°C) 0.92420 (( ))

0.00000

((

))

KB2

(( ))

((

KB3 MCNP Bias KB4 Normal Condition Sensitivity Adder

))

KBias

((

))

+ (( ))

++ The positive K uncertainties from Table 5-9 included in the KBias uncertainty roll-up Table 5-11: Abnormal Configuration In-Rack K Results-Checkerboard Loading Term Configuration In-Rack k

Error (1)

K K

Uncertainty (2)+

KB1A Channeled Flood-Optimum Density Water (0.10 g/cc, 20°C)

  • 0.91049

((

0.33079

((

KB1B Non-Channeled Flood-Optimum Density Water (0.10 g/cc, 20°C) 0.91396

))

0.32974

))

KB2

(( ))

((

KB3 MCNP Bias

))

KBias

((

))

  • For conservatism, only positive values that are the largest for their respective term are considered

+ (( ))

Figure 5-6 provides a graph of the optimum moderation results with the checkerboard array loading of non-channeled fuel assemblies. This study demonstrates that the highest reactivity occurs with a water density of 0.10 g/cc.

003N7421-NP Revision 1 Non-Proprietary Information Page 32 of 47 Figure 5-6: Optimum Moderation Results - Keff vs Percent Water Moderation 5.8 TOLERANCE ANALYSIS 5.8.1 Analytic Models The following tolerance study configurations were explicitly considered for the NFV:

Fuel enrichment increases by (( )) U-235 Fuel pellet density increased by (( )) of nominal value Gadolinia wt% decrease from nominal by (( ))

Rod cladding thickness increase by (( ))

Rod cladding thickness decrease by (( ))

Rack wall thickness decrease by ((

))

Rack wall thickness increase by ((

))

Rack pitch decrease by (( ))

Rack pitch increase by (( ))

Inter-rack pitch decrease by (( ))

003N7421-NP Revision 1 Non-Proprietary Information Page 33 of 47 Inter-rack pitch increase by (( ))

The models developed for these studies were all based off the normal configuration presented in Section 5.6 for the full loading configuration (both dry and flooded). As the full loading will maximize the reactivity effects of these changes, the K values will be applied to both the full loading and the checkerboard array based on this study.

5.8.2 Results-Dry Conditions The results of the tolerance studies are provided in Table 5-12. The K term in this table represents the difference between the system reactivity with the specified tolerance perturbation and the KNormal associated with the full loading of full in dry conditions. The total contribution from these independent tolerances to Kmax(95/95) of the NFV under dry conditions was found using Equation (5-2). In this equation, a KTi value must be both positive and the largest for its respective term to be considered.

K=

(5-2)

Table 5-12: Tolerance Study In-Rack K Results-Full Loading, Dry Term Configuration In-Rack k

Error (1)

K K

Uncertainty (2)+

KT1 Fuel Enrichment Increase by (( ))

0.70860

((

0.00389

((

KT2 Fuel Pellet Density Increase by (( ))

0.70620 0.00149 KT3 Gadolinia wt% Decrease by (( ))

0.70517 0.00046 KT4A Rod Clad Thickness Increase by (( ))

0.70316

-0.00155 KT4B Rod Clad Thickness Decrease by (( ))

  • 0.70621 0.00150 KT5A In-Rack Pitch Increase 0.70411

-0.00060 KT5B In-Rack Pitch Decrease

  • 0.70498 0.00027 KT6A Between-Rack Pitch Increase 0.70402

-0.00069 KT6B Between-Rack Pitch Decrease

  • 0.70518 0.00047 KT7A Wall Thickness Increase 0.69747

-0.00724 KT7B Wall Thickness Decrease

  • 0.71207

))

0.00736 KTolerance 0.00862

))

  • For conservatism, only positive values that are the largest for their respective term are considered

+ (( ))

5.8.3 Results-Flooded Conditions The results of the tolerance studies are provided in Table 5-13 for flooded conditions. The K term in this table represents the difference between the system reactivity with the specified

003N7421-NP Revision 1 Non-Proprietary Information Page 34 of 47 tolerance perturbation and KNormal associated with the full loading of fuel in flooded conditions.

The total contribution from these independent tolerances to the maximum Kmax(95/95) of the NFV under flooded conditions was found using Equation (5-2). In this equation, a KTi value must be both positive and the largest for its respective term to be considered.

Table 5-13: Tolerance Study In-Rack K Results-Full Loading, Flooded Term Configuration In-Rack k

Error (1)

K K

Uncertainty (2)+

KT1 Fuel Enrichment Increase by ((

))

0.92795

((

0.00375

((

KT2 Fuel Pellet Density Increase by (( ))

0.92591 0.00171 KT3 Gadolinia wt% Decrease by (( ))

0.92538 0.00118 KT4A Rod Clad Thickness Increase by (( ))

  • 0.92457 0.00037 KT4B Rod Clad Thickness Decrease by (( ))

0.92384

-0.00036 KT5A In-Rack Pitch Increase 0.92172

-0.00248 KT5B In-Rack Pitch Decrease

  • 0.92734 0.00314 KT6A Between-Rack Pitch Increase 0.91887

-0.00533 KT6B Between-Rack Pitch Decrease

  • 0.92847 0.00427 KT7A Wall Thickness Increase
  • 0.92517 0.00097 KT7B Wall Thickness Decrease 0.92164

))

-0.00256 KTolerance 0.00690

))

  • For conservatism, only positive values that are the largest for their respective term are considered

+ (( ))

5.9 UNCERTAINTY VALUES The total contribution to Kmax(95/95) of each NFV configuration from the problem and code specific uncertainties was found using Equation (5-3) and the values in Table 5-14 through Table 5-17.

K=

(5-3)

003N7421-NP Revision 1 Non-Proprietary Information Page 35 of 47 Table 5-14: Uncertainty K Values-Full Loading, Dry Term Description Value KU1 Critical Benchmark Uncertainty (95/95) (MCNP)

((

KU2 TGBLA Eigenvalue Uncertainty (95/95)

KU3 Uncertainty on KNormal (2)

KU4 Uncertainty of KBias Contributors (2)

KU5 Uncertainty of KTolerance Contributors (2)

KUncertainty

))

Table 5-15: Uncertainty K Values-Full Loading, Flooded Term Description Value KU1 Critical Benchmark Uncertainty (95/95) (MCNP)

((

KU2 TGBLA Eigenvalue Uncertainty (95/95)

KU3 Uncertainty on KNormal (2)

KU4 Uncertainty of KBias Contributors (2)

KU5 Uncertainty of KTolerance Contributors (2)

KUncertainty

))

Table 5-16: Uncertainty K Values-Checkerboard Loading, Dry Term Description Value KU1 Critical Benchmark Uncertainty (95/95) (MCNP)

((

KU2 TGBLA Eigenvalue Uncertainty (95/95)

KU3 Uncertainty on KNormal (2)

KU4 Uncertainty of KBias Contributors (2)

KU5 Uncertainty of KTolerance Contributors (2)

KUncertainty

))

Table 5-17: Uncertainty K Values-Checkerboard Loading, Flooded Term Description Value KU1 Critical Benchmark Uncertainty (95/95) (MCNP)

((

KU2 TGBLA Eigenvalue Uncertainty (95/95)

KU3 Uncertainty on KNormal (2)

KU4 Uncertainty of KBias Contributors (2)

KU5 Uncertainty of KTolerance Contributors (2)

KUncertainty

))

003N7421-NP Revision 1 Non-Proprietary Information Page 36 of 47 5.10 MAXIMUM REACTIVITY The Kmax(95/95) considering all biases, tolerances, and uncertainties, was calculated using Equation (5-4). The final values are presented in Table 5-18 through Table 5-21.

(/) = + + +

(5-4)

Table 5-18: NFV Rack Results Summary-Full Loading, Dry Term Value KNormal 0.70471 KBias

(( ))

KTolerance 0.00862 KUncertainty

(( ))

Kmax(95/95) 0.72116 Table 5-19: NFV Rack Results Summary-Full Loading, Flooded Term Value KNormal 0.92420 KBias

(( ))

KTolerance 0.00690 KUncertainty

(( ))

Kmax(95/95) 0.93919 Table 5-20: NFV Rack Results Summary-Checkerboard Loading, Dry Term Value KNormal 0.58422 KBias

(( ))

KTolerance 0.00862 KUncertainty

(( ))

Kmax(95/95) 0.60068 Table 5-21: NFV Rack Results Summary-Checkerboard Loading, Optimum Moderation Term Value KNormal 0.58422 KBias

(( ))

KTolerance 0.00862 KUncertainty

(( ))

Kmax(95/95) 0.93152

003N7421-NP Revision 1 Non-Proprietary Information Page 37 of 47

6.0 CONCLUSION

S The GE Low Density Fuel Storage racks have been analyzed for the storage of GNF3 fuel in the new fuel vault using the MCNP-05P Monte Carlo neutron transport program and the k criterion methodology. A maximum cold, uncontrolled in-core eigenvalue (k) of 1.31 as defined by TGBLA06 is specified as the rack design limit for GNF3 fuel stored in the new fuel vault. Full loading of fuel (assuming SIL-152 compliance) and a checkerboard array loading of fuel with consideration given to optimum moderation have been analyzed. All analyses resulted in a storage rack maximum k-effective (Kmax(95/95)) less than 0.90 for dry storage conditions, and less than 0.95 for credible abnormal operation with tolerances and uncertainties taken into account.

Furthermore, for cases where optimum moderation is a credible event for the storage of fresh fuel (i.e. non-compliant with SIL 152), the analyses resulted in a Kmax(95/95) less than 0.98.

If a plant is not SIL-152 compliant, a checkerboard array must be employed where only one out of every three storage locations in either linear direction contains a fuel bundle.

003N7421-NP Revision 1 Non-Proprietary Information Page 38 of 47

7.0 REFERENCES

1. SIL-152. Criticality Margins for Storage of New Fuel. San Jose, CA : s.n., 1976.
2. Criticality Accident Requirements, 10 C.F.R. § 50.68.
3. U.S. Nuclear Regulatory Commission. Standard Review Plan (SRP) 9.1.1 Criticality Safety of Fresh and Spent Fuel Storage and Handling. 2007. NUREG-0800.
4. General Design Criteria for Nuclear Power Plants, 10 CFR § 50 app. A.
5. U.S. Nuclear Regulatory Commission. NRC Information Notice 2011-03: Nonconservative Criticality Safety Analysis for Fuel Storage. ADAMS Accession Number: ML103090055.
6. X-5 Monte Carlo Team. MCNP-A General Monte Carlo N-Particle Transport Code, Version 5. Los Alamos National Laboratory. 2008. LA-UR-03-1987.
7. U.S. Nuclear Regulatory Commission. Guide for Validation of Nuclear Criticality Safety Calculational Methodology. 2001. NUREG/CR-6698.
8. Taylor, J. R. An Introduction to Error Analysis. 2nd. s.l. : University Science Books, 1982, pp. 268-271.

003N7421-NP Revision 1 Non-Proprietary Information Page 39 of 47 Appendix A - MCNP-05P Code Validation Table A-1 presents the results of the (( )) benchmark calculations. Note that it is necessary to make an adjustment to the calculated keff value if the critical experiment being modeled was not at a critical state. This adjustment is done by normalizing the kcalc values to the experimental values, which is valid for small differences in keff. This normalization is reported as knorm and is determined using Equation (A-1). The combined uncertainty from the measurement and the calculation (t) is also determined using Equation (A-2).

=

(A-1)

=

+

(A-2)

Table A-1: MCNP-05P Benchmark Calculation Results Experiment Expt.

Benchmark Eigenvalue (kexp)

Experimental Uncertainty (exp)

MCNP-05P Result (kcalc)

MCNP-05P Uncertainty (calc)

Norm.

Result (knorm)

Combined Uncertainty (t)

((

003N7421-NP Revision 1 Non-Proprietary Information Page 40 of 47 Experiment Expt.

Benchmark Eigenvalue (kexp)

Experimental Uncertainty (exp)

MCNP-05P Result (kcalc)

MCNP-05P Uncertainty (calc)

Norm.

Result (knorm)

Combined Uncertainty (t)

003N7421-NP Revision 1 Non-Proprietary Information Page 41 of 47 Experiment Expt.

Benchmark Eigenvalue (kexp)

Experimental Uncertainty (exp)

MCNP-05P Result (kcalc)

MCNP-05P Uncertainty (calc)

Norm.

Result (knorm)

Combined Uncertainty (t)

003N7421-NP Revision 1 Non-Proprietary Information Page 42 of 47 Experiment Expt.

Benchmark Eigenvalue (kexp)

Experimental Uncertainty (exp)

MCNP-05P Result (kcalc)

MCNP-05P Uncertainty (calc)

Norm.

Result (knorm)

Combined Uncertainty (t)

003N7421-NP Revision 1 Non-Proprietary Information Page 43 of 47 Experiment Expt.

Benchmark Eigenvalue (kexp)

Experimental Uncertainty (exp)

MCNP-05P Result (kcalc)

MCNP-05P Uncertainty (calc)

Norm.

Result (knorm)

Combined Uncertainty (t)

))

To determine if any trend is evident in this pool of experiments, the parameters listed in Table A-2 were considered as independent variables.

Table A-2: Trending Parameters Energy of the Average Lethargy causing Fission (EALF)

Uranium Enrichment (wt% U-235)

Plutonium Content (wt% Pu239)

Atom of ratio of hydrogen to fissile material (H/X)

To check for trends in the data, a linear regression was performed. The linear regression fitted equation is in the form y(x)= a +bx, where y is the dependent variable (knorm) and x is any of the predictor variables from Table A-2. Unweighted knorm values were used in this evaluation, though it is noted that, due to the very similar values reported in Table A-1, using weighted values would produce very similar results. This regression was performed using the built-in regression analysis tool in Excel. A useful tool to validate data correlation is the linear correlation coefficient. This is a quantitative measure of the degree to which a linear relation exists between two variables. It is often expressed as the square term, r2, and can be calculated directly using built in functions in Excel. The closer r2 gets to the value of 1, the better the fit of data is expected to be to the linear equation. Results from this linear regression evaluation are summarized in Table A-3.

A second method to test for goodness of fit is the chi squared test (2). This method is explained in detail in Reference (8). In general, it can be stated that 2 is an indicator of the agreement between the observed (calculated) and expected (fitted) values for some variable. For linear goodness of fit testing using this method, Equation (A-3) is utilized, where the expected value of f(xi) corresponds to the linear fitted equation for the trending parameter, xi.

003N7421-NP Revision 1 Non-Proprietary Information Page 44 of 47

=,()

(A-3)

A more convenient way to report this result is the reduced chi squared value, which is denoted as and is defined by Equation (A-4), where d is the degrees of freedom for the evaluation.

= /

(A-4)

If a value of order one or less is obtained for this equation, then there is no reason to doubt the expected (fitted) distribution is reasonable; however, if the value is much larger than one, the expected distribution is unlikely to be a good fit. Results for each trending parameter are summarized in Table A-3.

Table A-3: Trending Results Summary Trend Parameter Intercept Slope r2 Valid Trend H/X

((

No U-235 wt%

No EALF No Pu-239 wt%

))

No The results in Table A-3 clearly demonstrate that there are no statistically significant or valid trends of knorm with any of the trending parameters.

As no trends are apparent in the critical experiment results, a weighted single-sided tolerance limit methodology is utilized to establish the bias and bias uncertainty for this AOA and code package combination. Use of this method requires the critical experiment results to have a normal statistical distribution. This was verified using the Anderson-Darling normality. A graphical image of the results for this normality test, including the p-value for the distribution, is provided in Figure A-1. Because the reported p-value is greater than 0.05, it is confirmed that the data fits a normal distribution, and the single sided tolerance limit methodology is confirmed to be applicable.

003N7421-NP Revision 1 Non-Proprietary Information Page 45 of 47

((

))

Figure A-1: Normality Test of knorm Results When using this method, the weighted bias and bias uncertainty are calculated using the following equations:

= 1 (A-5)

=

=

=

n i

t n

i t

i norm norm k

k 1

2 1

2 1

(A-6)

=

(A-7)

003N7421-NP Revision 1 Non-Proprietary Information Page 46 of 47 2

2

+

=

s S P (A-8)

=

=

n i

t n

1 2

2 1

(A-9)

(

)

=

=

=

n i

t n

i norm i

norm t

n k

k n

s 1

2 2

1 2

2 1

1 1

1 1

(A-10)

Where:

norm k

= Average weighted knorm P

S = Pooled standard deviation 2

s = Variance about the mean 2

= Average total variance U = one-sided tolerance factor for n data points at (95/95 confidence/probability level) n = number of data points (( ))

Table A-4 summarizes the results of these calculations.

A validation of MCNP-05P using ENDF/B-VII.0 nuclear cross section data has been performed according to the general methodology described in NUREG/CR-6698 Guide for Validation of Nuclear Criticality Safety Calculational Methodology for BWR fuel lattices both in and out of fuel storage racks (7). As seen in Table A-4, ((

)). The recommended bias and bias uncertainty for use with evaluations within the prescribed AOA provided in Table 3-2 are summarized in Table A-5.

003N7421-NP Revision 1 Non-Proprietary Information Page 47 of 47 Table A-4: Bias and Bias Uncertainty for MCNP-05P with ENDF/B-VII Bias (weighted)

((

Bias Uncertainty(95/95 level)

Variance About the Mean Average Total variance Pooled Standard Deviation (1)

One-Sided Tolerance Factor

))

Table A-5: Recommended Bias and Bias Uncertainty Bias

((

Bias Uncertainty (95/95)

))

ATTACHMENT 3 RS-22-108 Global Nuclear Fuels - Americas, LLC 10 CFR 2.390 Affidavit for Attachment 4

Global Nuclear Fuel - Americas, LLC RS-22-108 Affidavit Page 1 of 3 AFFIDAVIT I, Kent Halac, state as follows:

(1) I am the Senior Engineer, Global Nuclear Fuel - Americas, LLC (GNF-A), and have been delegated the function of reviewing the information described in paragraph (2) which is sought to be withheld, and have been authorized to apply for its withholding.

(2) The information sought to be withheld is contained in the letter from P. R. Simpson (Constellation Energy Generation, LLC) to the Nuclear Regulatory Commission, RS-22-108, Response to Request for Additional Information RE: LaSalle County Station, Units 1 and 2 and Quad Cities Nuclear Power Station, Units 1 and 2 License Amendments Related to Fuel Storage, dated October 5, 2022. GNF-A proprietary information in RS-22-108 is identified by a dotted underline inside double square brackets. ((This sentence is an example {3})). GNF-A proprietary information in figures and large objects is identified by double square brackets before and after the object. In each case, the superscript notation {3} refers to Paragraph (3) of this affidavit, which provides the basis for the proprietary determination.

(3) In making this application for withholding of proprietary information of which it is the owner or licensee, GNF-A relies upon the exemption from disclosure set forth in the Freedom of Information Act (FOIA), 5 U.S.C. §552(b)(4), and the Trade Secrets Act, 18 U.S.C. §1905, and NRC regulations 10 CFR 9.17(a)(4), and 2.390(a)(4) for trade secrets (Exemption 4). The material for which exemption from disclosure is here sought also qualifies under the narrower definition of trade secret, within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission, 975 F.2d 871 (D.C. Cir. 1992), and Public Citizen Health Research Group v. FDA, 704 F.2d 1280 (D.C. Cir. 1983).

(4) The information sought to be withheld is considered to be proprietary for the reasons set forth in paragraphs (4)a and (4)b. Some examples of categories of information that fit into the definition of proprietary information are:

a.

Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by GNF-A's competitors without a license from GNF-A constitutes a competitive economic advantage over other companies;

b.

Information that, if used by a competitor, would reduce its expenditure of resources or improve its competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product;

c.

Information that reveals aspects of past, present, or future GNF-A customer-funded development plans and programs, resulting in potential products to GNF-A;

Global Nuclear Fuel - Americas, LLC RS-22-108 Affidavit Page 2 of 3

d.

Information that discloses trade secret or potentially patentable subject matter for which it may be desirable to obtain patent protection.

(5) To address 10 CFR 2.390(b)(4), the information sought to be withheld is being submitted to NRC in confidence. The information is of a sort customarily held in confidence by GNF-A and is in fact so held. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by GNF-A, not been disclosed publicly, and not been made available in public sources. All disclosures to third parties, including any required transmittals to the NRC, have been made, or must be made, pursuant to regulatory provisions for proprietary or confidentiality agreements or both that provide for maintaining the information in confidence. The initial designation of this information as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in the following paragraphs (6) and (7).

(6) Initial approval of proprietary treatment of a document is made by the manager of the originating component, who is the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge, or who is the person most likely to be subject to the terms under which it was licensed to GNF-A.

(7) The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist, or other equivalent authority for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside GNF-A are limited to regulatory bodies, customers, and potential customers, and their agents, suppliers, and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary and/or confidentiality agreements.

(8) The information identified in paragraph (2) is classified as proprietary because it contains the detailed GNF-A methodology for fuel analyses for the GNF-A Boiling Water Reactor (BWR). These methods, techniques, and data along with their application to the design, modification, and analyses associated with the fuel analyses were achieved at a significant cost to GNF-A.

The development of the evaluation processes along with the interpretation and application of the analytical results is derived from the extensive experience databases that constitute a major GNF-A asset.

(9) Public disclosure of the information sought to be withheld is likely to cause substantial harm to GNF-A's competitive position and foreclose or reduce the availability of profit-making opportunities. The information is part of GNF-A's comprehensive BWR safety and technology base, and its commercial value extends beyond the original development cost.

The value of the technology base goes beyond the extensive physical database and

Global Nuclear Fuel - Americas, LLC RS-22-108 Affidavit Page 3 of 3 analytical methodology and includes development of the expertise to determine and apply the appropriate evaluation process. In addition, the technology base includes the value derived from providing analyses done with NRC-approved methods.

The research, development, engineering, analytical and NRC review costs comprise a substantial investment of time and money by GNF-A. The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial. GNF-A's competitive advantage will be lost if its competitors are able to use the results of the GNF-A experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.

The value of this information to GNF-A would be lost if the information were disclosed to the public. Making such information available to competitors without there having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall and deprive GNF-A of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment in developing and obtaining these very valuable analytical tools.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on this 5th day of October 2022.

Kent Halac Senior Engineer, Regulatory Affairs Global Nuclear Fuels - Americas, LLC 3901 Castle Hayne Road Wilmington, NC 28401 Kent.Halac@ge.com