RS-15-230, Final, Impingement and Entrainment Characterization Study

From kanterella
Jump to navigation Jump to search

Final, Impingement and Entrainment Characterization Study
ML15243A204
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 08/27/2015
From:
EA Engineering, Science, & Technology
To:
Exelon Generation Co, Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML15243A197 List:
References
RS-15-230, TAC MF5567, TAC MF5568
Download: ML15243A204 (150)


Text

FINAL Impingement and Entrainment Characterization Study LaSalle County Station Prepared for:

Exelon Generation Company, LLC 200 Exelon Way Kennett Square, Pennsylvania Prepared by:

EA Engineering, Science, and Technology, Inc., PBC 444 Lake Cook Road, Suite 18 Deerfield, Illinois 60015 August 2015 15004.03

TABLE OF CONTENTS

1. INTRODUCTION.................................................................................... 1-1 1.1. STUDY OBJECTIVES.......................................................................

1-1 1.2. SITE DESCRIPTION..........................................................................

1-2

2. METHODS...........................................................................................

2-1 2.1. SAMPLING FREQUENCY AND DURATION..........................................

2-1 2.1.1. Impingement............................................................................... 2-1 2.1.2. Entrainment................................................................................. 2-1 2.2. SAMPLE COLLECTION AND PROCESSING.........................................

2-1 2.2.1. Impingement................................................................................. 2-1 2.2.2. Entrainment................................................................................. 2-2 2.3. IMPINGEMENT DATA MANAGEMENT AND ANALYSIS........................

.2-4 2.3.1. Data Management.......................................................................... 2-4 2.3.2. Makeup Water Volume and Water Temperature........................................ 2-4 2.3.3. Impingement Estimates.................................................................... 2-4 2.4. ENTRAINMENT DATA MANAGEMENT AND ANALYSIS......................... 2-5 2.4.1. Data Management.......................................................................... 2-5 2.5. QUALITY ASSURANCE/QUALITY CONTROL.......................................

2-5

3. RESULTS............................................................................................. 3-1 3.1. IMPINGEMENT RESULTS................................................................

3-1 3.1.1. Water Quality............................................................................... 3-1 3.1.2. Species Composition and Relative Abundance......................................... 3-1 3.1.3. Size Distributions.......................................................................... 3-2 3.1.4. Seasonal Impingement..................................................................... 3-2 3.1.5. Impingement Estimates.................................................................... 3-3 3.2. ENTRAINMENT.............................................................................. 3-4 3.2.1. Sampling Conditions....................................................................... 3-4 3.2.2. Species Composition and Relative Abundance......................................... 3-4 i

TABLE OF CONTENTS (Continued) 3.2.3. Size Distribution........................................................................... 3-4 3.2.4. Diel Distribution........................................................................... 3-5 3.2.5. Depth Distribution......................................................................... 3-5 3.2.6. Seasonal Distribution...................................................................... 3-5 3.2.7. Entrainment Estimate...................................................................... 3-6

4. DISCUSSION........................................................................................ 4-1 4.1. IMPINGEMENT...............................................................................

4-1 4.2. ENTRAINMENT.............................................................................. 4-2

5. REFERENCES....................................................................................... 5-1 FIGURES TABLES APPENDIX A -

Raw impingement data collected at LaSalle County Station River Screen APPENDIX B -

APPENDIX C -

APPENDIX D -

House by sampling date, April 2014-March 2015.

Number, biomass, and relative abundance of shellfish and fish collected during impingement study at LaSalle County Station River Screen House by sampling date, April 2014-March 2015.

CPE by number (No. per volume) and weight (Kg. per volume) for shellfish and fish collected during impingement study at LaSalle County Station River Screen House by sampling date, April 2014-March 2015.

Raw ichthyoplankton entrainment data collected at LaSalle County Station River Screen House, April 2014-August 2014.

ii

LIST OF FIGURES Number 1

Site of LaSalle County Station River Screen House (RSH) 2 Estimated Impingement for Each Extrapolation Period at LaSalle County Station, April 2014 through March 2015 3

Estimated Entrainment of Ichthyoplankton for Each Extrapolation Period at LaSalle County Station, 30 March -30 August 2014.

4 Estimated Entrainment of Dominant Ichthyoplankton Taxa for Each Extrapolation Period at LaSalle County Station, 30 March -30 August 2014 iii

LIST OF TABLES Number 1

Summary of Makeup Water Withdrawal during Impingement Sampling and Extrapolation Periods, LaSalle County Station River Screen House, April 2014 through March 2015.

2 Summary of Makeup Water Withdrawal during Entrainment Sampling and Extrapolation Periods, LaSalle County Station River Screen House, April - August 2014.

3 Water Temperatures Recorded during Impingement Sampling Events, LaSalle County Station River Screen House, April 2014 through March 2015.

4 Family, Common, and Scientific Names of Crayfish, Mussels, and Fishes Collected During Impingement Sampling at LaSalle County Station River Screen House, April 2014 through March 2015.

5 Number and Biomass of Crayfish, Mussels, and Fish Collected During Impingement Sampling at LaSalle County Station River Screen House, April 2014 through March 2015.

6 Total Length (mm) Data for Fish Impinged at LaSalle County Station River Screen House, April 2014 through March 2015.

7 Monthly Length Frequency Distribution for Gizzard Shad Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

8 Monthly Length Frequency Distribution for Threadfm Shad Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

9 Monthly Length Frequency Distribution for Bluegill Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

10 Monthly Length Frequency Distribution for Freshwater Drum Impinged at LaSalle County'Station River Screen House, April 2014 - March 2015.'

11 Monthly Length Frequency Distribution for Round Goby Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

12 Length Frequency Distribution for Five Abundant Species Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

13 Comparison of Length Data for Sportfish Impinged at LaSalle County Station River Screen House to Stock and Quality Length Categories.

iv

LIST OF TABLES (Continued)

Number 14 Impingement Estimates at LaSalle County Station River Screen House, April 2014 through March 2015.

15 Water Temperatures Recorded during Entrainment Sampling Events, LaSalle County Station River Screen House, 3 April - 26 August 2014.

16 Summary of Water Temperature, Dissolved Oxygen, and Current Velocity Measurements during Entrainment Sampling at LaSalle County Station River Screen House, 3 April - 26 August 2014.

17 Number and Relative Abundance of Ichthyoplankton Taxa Collected during Entrainment Sampling at LaSalle County Station River Screen House, 3 April - 26 August 2014.

18 Fish Larvae Length and Fish Egg Diameter (millimeters) Statistics for Ichthyoplankton from Entrainment Samples Collected at LaSalle County Station River Screen House, 3 April - 26 August 2014.

19 Diel Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during All Entrainment Sampling Events at LaSalle County Station River Screen House, 3 April - 26 August 2014.

20 Diel Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Each Entrainment Sampling Event at LaSalle County Station River Screen House, 3 April - 26 August 2014.

21 Depth Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during All Entrainment Sampling Events at LaSalle County Station River Screen House, 3 April - 26 August 2014.

22 Depth Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Each Entrainment Sampling Event at LaSalle County Station River Screen House, 3 April - 26 August 2014.

23 Ichthyoplankton Taxa Entrainment Estimates for LaSalle County Station River Screen House, 30 March-30 August 2014.

24 Comparison of Annual Impingement and Entrainment Estimates between LaSalle County Station and Other Generating Stations within the Illinois River Watershed.

V

1. INTRODUCTION An impingement mortality and entrainment characterization study was conducted at the River Screen House (RSH) on the Illinois River during 2014/ 2015 for Exelon's LaSalle County Station (LSCS). Because LSCS utilizes a closed-cycle recirculating cooling system (i.e., a 2058 acre cooling pond) for cooling of plant condensers, it has been determined in accordance with the Best Professional Judgment (BPJ) provisions of 40 CFR 125.3 to be the equivalent of Best Technology Available (BTA) for cooling water intake structures to prevent/minimize impingement mortality. Accordingly, the purpose of the study described herein was solely to collect current aquatic biological information needed to support preparation of the Environmental Report submitted as part of a U.S. Nuclear Regulatory Commission (NRC) license renewal application.

1.1. STUDY OBJECTIVES Exelon Generation Company, LLC (Exelon) contracted EA Engineering, Science, and Technology, Inc., PBC (EA) to perform the LSCS Impingement Mortality and Entrainment Characterization Study (IMECS), which included a one-year impingement study conducted from April 2014 through March 2015 and a seasonal entrainment study conducted during the 2014 spawning season (April through August). The entrainment study was conducted during fish spawning and rearing periods typical for northern Illinois. Specific objectives of the study were to:

  • Describe the fish and shellfish taxa composition in the impingement and entrainment samples collected from the LSCS makeup water intake structure at the RSH under normal operations; Note the presence of any rare or listed species and the significance of such collections;
  • As appropriate, note and discuss the presence of unusually large numbers of recreationally important species (e.g., black bass, temperate bass, and channel catfish);

Provide size (length) distributions of the commonly impinged species; Characterize entrainment of each taxon according to life stage;

  • Describe temporal patterns of the impingement and entrainment rates; Provide annual impingement estimates by number and weight for all species combined and
  • for each species currently occurring at the LSCS makeup water intake structure under normal operations;
  • Provide entrainment estimates for all taxa combined and by taxon and life stage currently occurring at the LSCS makeup water intake structure under normal operations;
  • Describe the overall contribution of invasive species or taxa;
  • Describe QA/QC procedures that were followed to ensure the accuracy of all data collected and calculations made; and 1-1
  • Provide appendices that include all raw data collected, including plant operating and water temperature data.

1.2. SITE DESCRIPTION LSCS is located near the Illinois River in LaSalle County about 75 miles southwest of Chicago and 11 miles southeast of Ottawa, Illinois. LSCS is a two-unit, nuclear-powered, steam electric generating facility that began commercial operation in 1984. The annual mean net electrical power capacity rating for the Station is 2,327 megawatts electric (MWe).

Condenser cooling water and plant service water are provided by an approximately 833 hectare (ha) diked cooling pond adjacent to the plant. The RSH on the Illinois River provides makeup water to the cooling pond (Figure 1). The discharge structure where blowdown from the cooling pond is returned enters the Illinois River approximately 900 feet downstream of the RSH. The IMECS was conducted entirely in relation to makeup water withdrawal at the RSH.

Makeup cooling water is withdrawn from the Illinois River at river mile 249.5, four miles north of LSCS and three miles upstream of the Marseilles Dam. Makeup water withdrawn from the Illinois River by the RSH is conveyed approximately 3.5 miles to the cooling pond to replace losses due to evaporation, blowdown, and seepage using a combination of three makeup pumps.

Makeup water requirements can be met by operating one or two pumps during normal operations with one pump for backup. The rated capacity of each pump is 30,000 gallons per minute (gpm).

Maximum water withdrawal from the Illinois River is, therefore, approximately 90,000 gpm.

Normal water withdrawal, with two pumps operating, is up to 60,000 gpm.

The makeup water intake system consists of an intake flume channeled into the bottom of the Illinois River extending approximately 50 ft from the shoreline. Recessed about 25 ft from the shoreline is a 72 ft wide funnel inlet. At the mouth of the inlet, a floating log boom diverts floating debris and, in the RSH forebay, a permanent floating oil boom prevents spilled oil from entering the river. The inlet leads to two adjacent bar grills and traveling screens, with 3/8 inch screen openings, in the RSH. When the cooling pond is at or near full pool, only one or two makeup water pumps are required to maintain the pond's water level.

Water velocities in the RSH forebay range from 0.3 to 0.5 ft/second with one pump operating to 0.6 to 1.0 ft/second with two pumps operating, depending on river level. The velocity at the face of the travelling screens is 0.5 ft/second during one-pump full-flow operation and 0.9 ft/second during two-pump full-flow operation. Debris removed from the traveling screens by a screen backwash system and from the bar grills by trash rakes is collected in a trash basket and disposed in an offsite permitted landfill. Consistent with State of Illinois regulations, trash basket contents are not returned to the Illinois River.

The following chapters provide a description of the study methods (Chapter 2) and the IMECS results (Chapter 3).

1-2

2. METHODS This chapter provides details for the RSH impingement and entrainment studies regarding sampling frequency and duration (Section 2.1), sample collection and processing procedures (Section 2.2), impingement (Section 2.3) and entrainment (Section 2.4) data management procedures, and quality assurance/quality control (QAIQC) measures (Section 2.5).

2.1. SAMPLING FREQUENCY AND DURATION 2.1.1. Impingement A total of 20 impingement samples were successfully collected at the RSH between 2 April 2014 and 31 March 2015 (Table 1), although scheduled outages, maintenance outages, and unworkable weather conditions resulted in cancellation or rescheduling of multiple scheduled sampling events. During each of the 20 successful sampling events, the 24-hour sampling duration goals were met.

2.1.2. Entrainment Sampling was conducted at one location in the RSH forebay on a frequency of once every two weeks in April 2014, once a week from 01 May through the week of 14 July, and once every two weeks during the remainder of July through the end of the study in August 2014. The sampling program represented 16 collection dates with duplicate samples collected from two depths (near surface and near bottom) and twice (day/night) during each sampling event yielding 128 samples (duplicate samples x 2 depths x 2 sample times x 16 sampling dates) for the entrainment study (Table 2).

2.2. SAMPLE COLLECTION AND PROCESSING 2.2.1. Impingement The impingement study focused on fish and shellfish, as this term has traditionally been interpreted by resource and regulatory agencies. Therefore, crayfish and native freshwater mussels were processed, but invasive taxa such as Corbicula (Asiatic clam) and Dreissena (zebra and quagga mussels) were excluded.

Exelon personnel were responsible for rotating the traveling screens and cleaning the collection basket prior to initiating scheduled sampling events. During each 24-hour sampling period, facility personnel were responsible for monitoring the collection basket to prevent it from overflowing. If the traveling screens were in the continuous mode (always rotating), there was no need to manually operate the traveling screens either before or at the end of the sampling event. However, when the traveling screens were being operated in other modes (e.g., manually, automatic, and/or on differential pressure), the traveling screens were manually operated at the start and end of each. 24-hour collection period. The mesh size. of the collection basket was the same size as the mesh size of the traveling screens (3/8-inch square mesh).

2-1

Impinged shellfish and fish were separated from the debris, identified, counted, weighed in grams (g) and total length (TL) was measured in millimeters (mam). Cyprinids (minnows), except for carp and goldfish, were counted and batch weighed. When 30 or fewer individuals of a single species were collected, all were individually measured and weighed, except as noted for minnows. When more than 30 individuals of a single species occurred in a sample and different size groups were obviously represented, fish were divided into small, medium, large size groups.

Specimens were then randomly selected from each group in proportion to the contribution of that size group to the whole sample, so that at least 30 individuals were measured and weighed individually. The remainder of the individuals of species represented by more than 30 individuals were then counted and batch weighed by size group.

All fish and shellfish impinged during each sampling event were typically processed on site; however, specimens that could not be positively identified were returned to EA's Deerfield, Illinois laboratory for identification and processing. Deteriorated or damaged fish were identified to the lowest possible taxonomic level. Fish that were obviously, dead longer than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (e.g.,

those exhibiting advanced decomposition, missing scales and eyes, and excessive fungus relative to other fish in the sample) were not processed. A voucher collection of preserved specimens that were positively identified by an experienced taxonomist was compiled. The collection included unusual or taxonomically difficult species.

Operating conditions during each study were supplied by Exelon including intake water temperature, number, and duration of pumps operating, and makeup water (MW) volume pumped by hour for each sampling event, as well as daily, weekly, and monthly MW volume totals. MW volume data were used to extrapolate impingement sample densities to total impingement estimates based on per unit volume of MW pumped.

2.2.2. Entrainment Entrainment samples were collected during the 2014 spawning season from late April through August. Entrainment samples were collected using 0.5-meter conical plankton nets with 505 g mesh suspended from the forebay bridge on the intake side of the log boom and within the hydraulic influence of the facility (Figure 1). It was assumed that organisms collected at that point would be entrained. Pairing of the nets provided replication at each depth (surface and bottom) on each sampling date thereby increasing the reliability of the estimates. One set of samples (i.e., duplicate samples near the surface and near bottom) was collected during the day oit least one hour before sunset and a second set was collected at night at least one hour after sunset to examine diel periodicity. Since barge traffic affected makeup water intake flow, sampling was not conducted while barges were passing the RSH.

A minimum of 50 cubic meters (in 3) of water was filtered for each sample, with sampling duration ranging from 8 to 36 minutes. The volume of water sampled was determined by a General Oceanics (GO) Model 2030R flow meter placed at the mouth of each net. If the volume of water sampled was less than 50 m3 (less than 9,500 revolutions on the GO flow meter), the nets were redeployed and sampling continued until a minimum of 50 mn 3 of water was. filtered.

2-2

At the conclusion of each tow, the nets were washed down to concentrate debris, fish eggs, fish larvae, and early life stages of shellfish into the attached collection cups, and preserved in 10%

formalin containing rose bengal.

Prior to sample collection, water temperature and velocity were measured at each sample depth.

Weather observations were also noted at the beginning of each sampling event, as well as significant changes (e.g., rapid rise/fall in air temperatures and thunderstorms) that may have occurred during the sampling event.

Ichthyoplankton (fish eggs, larvae, and juveniles) were hand sorted from the debris with the aid of illuminated magnifiers and/or dissecting microscopes. Ichthyoplankton were identified using a dissecting microscope equipped with polarizing lens.

Characters used to describe ichthyoplankton are qualitative, rather subjective, and change as early development progresses (e.g., pigmentation patterns). Quantitative characters such as myomere counts often show considerable overlap among species and can vary geographically and temporally for a given species (Bosley and Connor 1984). Thus, identifications for this study were made to the lowest practical taxon, which, for larval fish, sometimes was to the species level, but often to the genus level (e.g., Lepoinis or Moxostoma cannot typically be separated to species), and occasionally higher levels (e.g., family). On occasion, "species type" identifications were made where a specimen agreed with the species to which it was assigned, but the taxonomist could not be 100 percent certain that it was that species. Thus, a "species type" designation may not be the species indicated, but rather a species that shares many of the same larval characteristics with that species. Fish eggs typically cannot be identified to species or genus, but family level egg identifications were provided when possible.

Identifications were made using current references and taxonomic keys (e.g., Auer 1982, Wallus et al. 1990, Kay et al. 1994, Simon and Wallus 2003 and 2006) and selected specimens were verified by an outside consultant. Life stages of fish were categorized as egg, yolk-sac larvae, post yolk-sac larvae, and juveniles. Counts were made by taxon and life stage.

Operating conditions during each study were supplied by Exelon including intake water temperature, number, and duration of pumps operating, and MW volume pumped by hour for each sampling event, as well as daily, weekly, and monthly MW volume totals. MW volume data were used to extrapolate entrainment sample densities to total entrainment estimates based on per unit volume of MW pumped.

2-3

2.3. IMPIN'GEMENT DATA MANAGEMENT AND ANALYSIS 2.3.1. Data Management Field and laboratory data for each impingement sample were recorded on forms compatible for computer entry and all data processing activities were recorded on a log sheet for each batch of data. Following serialization, diga-coding, and QA/QC checks, the data were manually entered into an Excel spreadsheet. All (i.e., 100 percent) of the manually entered data were then compared against the hard copy field and laboratory data forms. All errors encountered were corrected and the data managed in a SAS format (Version 8.2).

Appendix A provides a raw data listing by sampling event. The number, biomass, and relative abundance of shellfish and fish collected during each impingement sampling event are provided in Appendix B.

2.3.2. Makeup Water Volume and Water Temperature MW volumes and intake water temperatures provided by Exelon were summed on a per-sample event and period basis. Mean, minimum, and maximum water temperatures were calculated for each sampling period based on data observed at the jointly operated U.S. Geological Survey and Exelon gaging station at Seneca, IL. This station is located downstream of the Main Street bridge in Seneca, approximately three miles upstream of the LSCS RSH.

2.3.3. Impingement Estimates Tabular results were prepared that provided the number and weight of each taxon collected during each 24-hr impingement sampling event (Appendix B). These daily results were extrapolated based on MW flow for all operating units to yield weekly estimates, which when summed, yielded annual impingement estimates by species. The sampling period species-specific impingement estimates, both by number and by weight, were calculated using the following formula:

Number or Weight (Biomass)

Collected.

Period Estimate=

x MW Volume MW Volume Sampled Where:MW Volume = Volume of makeup water withdrawn during a given extrapolation period (e.g., one week)

MW Volume Sampled = Volume of makeup water withdrawn during one sampling event (e.g., 24-hours)

The number and biomass extrapolations were based on the data summarized in Appendix B and were subsequently converted to catch per unit effort (CPE) or numberibiomass impinged per MW use (Appendix C). These CPE data were then multiplied by the MW flows (Table 1 to yield 2-4

estimates of the number and biomass of impinged organisms at the LSCS RSH over the course of the study (Appendix D).

2.4. ENTRAINMENT DATA MANAGEMENT AND ANALYSIS 2.4.1. Data Management Management of entrainment data generally followed processing activities for the impingement study (Section 2.3.1). Field and laboratory data for each sample were recorded on forms compatible with computer entry and each data batch was recorded on a log sheet. Following serialization, diga-coding, and QA/QC checks, the data were manually entered into a spreadsheet.

All (i.e., 100 percent) of the manually entered data were then compared against the hard copy field and laboratory data forms. All errors encountered were corrected and managed in a SAS format.

Tabular summaries that include total numbers, densities, and relative abundance by species or taxon were compiled from the laboratory data. MW volumes were summarized on a per-sample basis, as well as on a weekly (i.e., Sunday through Saturday), biweekly, and/or monthly basis.

Descriptive statistics (e.g., mean, minimum, and maximum values) were summarized for water temperature and dissolved oxygen (DO). Tabular results were prepared for the average density (during each 24-hour sampling event) of each taxon collected. These daily densities were then extrapolated based on MW volume withdrawn during specified time periods to yield period-specific (i.e., weekly, biweekly, or monthly) estimates that were ultimately summed to yield a total (i.e., April through August) annual estimate for 2014 (Table 2). The period-specific and taxon-specific entrainment estimates were calculated using the following formula:

Period Estimate = Daily Density x Period MW Volume Where: Daily Density = Abundance of entrained organisms in the samples from a given sampling event Period MW Volume =Volume of makeup water withdrawn during a given extrapolation period 2.5. QUALITY ASSURANCE/QUALITY CONTROL Project specific QC activities included:

  • Training - Staff collected and processed samples were adequately trained for their tasks.

This included familiarization with field and laboratory methods and any additional aspects that were required (e.g., equipment operation, processing/identification, site security and safety procedures);

  • Equipment - All equipment used during this study were calibrated and maintained to the manufacturer's recommendations. Calibrations were appropriately documented; and 2-5
  • Laboratory - All samples were recorded on project-specific sample control sheets.

Sample sorting efficiency was checked and recorded by re-sorting 10% of the samples.

Staff conducting identification of specimens had access to relevant taxonomic literature and a reference collection. A voucher collection of rare or unusual specimens was maintained with verification by an additional, outside taxonomic expert.

Prior to the first scheduled sampling event, a readiness review was conducted to ensure that trained personnel, and required equipment were in place. An experienced senior staff member accompanied field personnel during the initial sampling events to observe sampling activities and to verify that established methods were being followed. In addition, senior staff observed initial laboratory and data management activities to verify the same. Variances from approved procedures were corrected.

2-6

3. RESULTS 3.1. IMPINGEMENT RESULTS 3.1.1. Water Quality Daily minimum and maximum river temperatures recorded during the impingement sampling events ranged from 1.6 degrees Centigrade (°C) during the 26-27 January 2015 sampling event to 28.0°C during the 11-12 August 2014 sampling event (Table 3). Mean river temperatures ranged from 1.8°C to 27.6°C and exhibited normal seasonal patterns with summer highs and winter lows.

Dissolved oxygen (DO) concentrations were always adequate to support the warm-water fishery in the Illinois River, the source of makeup water for the LSCS cooling pond (Table 3). DO readings during the impingement sampling events ranged from 6.2 mg!L to 14.4 mg/L and averaged at least 7.0 mg/L during the study.

3.1.2. Species Composition and Relative Abundance A total of 46 fish and shellfish species were collected from the RSH traveling screens during the 20 impingement sampling events, including 41 fish species, two crayfish species, and three mussel species (Tables 4 and 5). The minnow and sunfish families accounted for 49% of the fish species with 13 and seven species, respectively. Other fish families represented by more than one species included the herrings, pikes and mudminnows, suckers, bullhead catfish, and percids.

Six families were represented by only one species. The impingement samples included six "shellfish"--tbree crayfish and three mussels (Table 3).

Thirty-six native species and five introduced/invasive fish species were impinged during the study (Table 4). A few native sportfish species were collected, including channel catfish, yellow bass, bluegill, largemouth bass, and walleye, but most were collected in low numbers (e.g., only one smallmouth bass and one walleye were collected during the study). Introduced/invasive species that were impinged included thread fin shad, goldfish, common carp, Oriental weatherfish, and round goby.

A total of 653 organisms weighing approximately 9 Ikilograms (kg) representing primarily fish were collected during the RSH impingement study (Table 5). Seventeen fish species accounted for 91% of the total number impinged and 64% of the biomass. Gizzard shad accounted for 29%

of the total number of fish collected and 18% of the total biomass. Impingement of native sportfish was low (10 fish or less) except for the bluegill, which ranked fourth in terms of number and fifth based on biomass. Two invasive species, threadfin shad and round goby, ranked second and third numerically, accounting for 20% of the total number of fish collected and 7.4% of the total biomass. Overall, 37 fish taxa were represented by 20 or fewer specimens (i.e., less than 1 specimen per sampling event) and 32 taxa were represented by fewer than 10 specimens. Sixteen taxa were each represented by a single specimen. The five introduced/invasive fish species that were collected during the study accounted for 27% of the 3-1

total number of fish collected and 19% of the biomass, largely reflecting the numerical contribution of thread fin shad and round goby and biomass contributions of common carp and round goby to the study totals.

Shellfish and fish species federally listed as endangered or threatened were not collected during the study (U.S. Fish and Wildlife Service 2015). One American eel, listed as threatened by Illinois (Illinois Endangered Species Protection Board 2015) was impinged.

3.1.3. Size Distributions The majority of organisms impinged at the RSH were small fish representing juveniles of larger species (e.g., gizzard shad and common carp) or juveniles and adults of smaller species (e.g.,

round goby). Measured total lengths of impinged fish ranged from a 36 millimeter (mam) bluegill to a 692 mm American eel (Table 6). Twenty-seven species or taxa had average total lengths that were less than 100 mm and nine species had average lengths between 100 mm and 199 mm. The most commonly impinged species were primarily from the 2014 year-class Total lengths of gizzard shad, the most abundant impinged species at the LSCS RSH ranged from 47 mm to 183 mm and represented twelve 10-mam size classes between 40 mm and 159 mm (Table 7). Approximately 89% of the gizzard shad were between 40 mm and 119 mm. Gizzard shad from the 2014 year-class dominated the impingement samples. The size distribution of impinged threadfin shad was similar to that for gizzard shad and was comprised exclusively of YOY less than 110 mm (Table 8).

Impinged bluegill were 30 to 161 mm in length but most were less than 100 mm (Table 9).

Those impinged in April and May were likely slow growing fish from the 2013 year-class, whereas fish less than 80 mm impinged from July through March were from the 2014 year class.

Nearly 75% of the impinged freshwater drum were from the 2014 year-class and the majority of those were collected in November and December (Table 10). The invasive round goby were all less than 100 mm (Table 11). In summary, the length frequency distributions of the five most abundant species indicate that primarily fish from the 2014 year-class were impinged at the RSH (Table 12).

The lengths of sportfish impinged at the RSH were compared to stock and quality length categories used to evaluate the status of a fishery (Gablehous¢ 1984). The average lengths of most of the impinged sportfish were less than the stock length with three exceptions (Table 13).

The average length of bluegill (81 mm) was slightly higher than the stock size (76 mm) and six bluegill exceeded the minimum quality length. Smallmouth bass and walleye approached their respective quality lengths, but only one individual of each species was collected (Table 13).

3.1.4. Seasonal Impingement Impingement varied widely by season during the one-year study, with estimated impingement ranging from 14 organisms during the 27 April - 10 May 2014 extrapolation period to 1,767 organisms during the 21 December 2014 - 10 January 2015 extrapolation period (Figure 2).

3-2

Gizzard shad comprised 89% of the 21 December - 10 January estimate, and only five other taxa were impinged. Estimated impingement exceeded 1,000 organisms on three other occasions:

11 -24 May 2014, 26 October -December 2014, and 11 -31 January 2015. The high 11 -24 May estimate included 20 taxa of which bluntnose minnow, freshwater drum, and round goby accounted for 65% (Appendix A). The 26 October - 6 December 2014 extrapolation period included 15 taxa with green sunfish, bluegill, and freshwater drum comprising about half of the estimate. The 11-31 January 2015 estimate included nine taxa but was dominated (59%) by gizzard shad.

Impingement rates were highest in the fall and winter months when water temperatures were lowest and recently recruited fish were susceptible to approach velocities at the RSH. Gizzard shad and threadfin shad are especially susceptible when water temperatures are below 10°C (Table 3).

3.1.5. Impingement Estimates.

The study estimate for impingement at the RSH was based on extrapolating results from twenty 24-hour impingement sampling events conducted from early April 2014 through March 2015.

The total number and biomass of shellfish and fish subject to impingement mortality was an estimated 10,673 organisms weighing 148 kg (Table 14). Gizzard shad comprised 30% of the estimated total number of organisms impinged and 20% of the total biomass. The six most commonly impinged species (gizzard shad, round goby, threadfin shad, bluegill, freshwater drum, and goldfish) collectively accounted for 67% of the total estimate by number and 46% of the biomass. Overall, 16 taxa accounted for 88% of the total estimate by number and 65% of the biomass.

Shellfish, represented by crayfish and mussels, were monitored during the study but accounted for less than 3% of the estimated annual impingement.

Native sportfish species comprised 19% of the total annual estimate and 31% of the total biomass. The overall contribution of native sportfish to the numerical estimate primarily reflects the numbers and biomass of bluegill and freshwater drum, which collectively accounted for 66%

of the impinged native sportfish and 55% of the biomass.

Introduced/invasive species comprised 26% of the total annual impingement estimate and 18% of the total biomass because of the relatively high numbers of the invasive round goby and threadfin shad, which accounted for 18% and 7% of the total biomass, respectively. Exclusion of invasive fish species from the annual estimate lowers the total number and biomass estimates of fish and shellfish subject to impingement mortality at the RSH to an estimated 7,919 organisms weighing 122 kg.

3-3

3.2. ENTRAINMENT 3.2.1. Sampling Conditions Mean intake temperatures during the entrainment characterization study ranged from 8.7°C on 3 April 2014 to 28.2°C on 22 July 2014 (Table 15). Intake temperatures increased by approximately 4°C between the 6 May and 13 May sampling and the 11 and 17 June sampling events (Table 15). The diel range in intake temperatures exhibited limited variation during the entrainment study as day time temperatures averaged 0.3 to 0.4°C higher than the nighttime temperatures (Table 16). Water temperatures also varied little with depth.

DO concentrations ranged from 6.8 mg/L to 14.0 mg/L during the study (Table 16). Mean nighttime DO averaged 8.6 mg/L compared to 9.6 mg/L during the day, but the nighttime concentrations were greater than 1.0 mg/L lower during seven of the sampling events and 2.4 and 3.5 mg/L lower during the 24 April and 6 May sampling events (Table 16). DO also varied little with depth.

Approach velocities to the RSH where the entrainment samples were collected ranged from 0.9 ft/sec to 1.8 ft/sec and were similar during the day and night sampling events (Table 16). As with temperature and DO, velocities were similar between the surface and bottom sampling depths and were sufficient to support an assumption that all ichthyoplankton collected would be entrained through the RSH.

3.2.2. Species Composition and Relative Abundance Ichthyoplankton taxa representing five life stages (egg, yolk-sac, post yolk-sac, larvae, and juveniles) were collected during the entrainment characterization study. A total of 7,114 ichthyoplankton specimens representing 12 families and 27 distinct taxa were reported (Table 17). The samples were dominated by taxa representing carps, minnows, and suckers, which collectively comprised 79% of the ichthyoplankton. Cyprinidae and common carp yolk-sac larvae accounted for 23% and 13% of the total ichthyoplankton, respectively. Yolk-sac Ictiobinae larvae comprised 25% of the ichthyoplankton and accounted for 94% of the sucker taxa/life stages collected (Table 17). Three other taxa/life stages each accounted for more than 3% of the ichthyoplanlkton: Pimnephales type yolk-sac larvae, common carp eggs, and freshwater drum eggs (Table 17). Only 10% of the specimens collected represented sportfish taxa (channel catfish, Morone, all centrarchid taxa, Sander, walleye, and freshwater drum). Freshwater drum life stages accounted for 76% of the sportfish total. Invasive species were represented by common carp and round goby. Other taxa besides the distinct taxa likely occurred in the samples, but it was not possible to differentiate them with certainty.

3.2.3. Size Distribution Fish eggs of six taxa were collected with diameters ranging from 0.7 mm (Morone/Pomoxis type) to 4.8 mm (Hypophthah~nichthys type). Average egg diameters ranged from 0.9 to 3.8 mm (Table 3-4

18). Lengths of 17 yolk-sac larvae taxa, which accounted for 77% of the ichthyoplankton, ranged from 1.0 mm (common carp) to 14.4 mm (Moxostoma). Average yolk-sac larvae lengths ranged from 2.9 mm to 13.3 mm. Lengths of post yolk-sac larvae, which accounted for only 6% of the ichthyoplankton collected during the study, ranged from 4.3 mm (Dorosoma) to 26.1 mm (gar) and average lengths ranged from 5.5 to 25.8 mm.

Juvenile taxa comprised only 3% of the total ichthyoplankton, representing 17 taxa with lengths ranging from 6.5 mm to 36 mm (Table 18). Average juvenile lengths ranged from 7.9 mm (round goby) to 35.5 mm (largemouth bass). The majority (77%) of entrained juveniles were round goby. Low abundance of juveniles in the ichthyoplankton samples is normal because as larvae develop and grow, they either move to habitats that make them less susceptible to entrainment and/or their swimming ability improves allowing some avoidance of the intake approach velocities.

3.2.4. Diel Distribution Night-time ichthyoplankton densities during the entrainment study were 50% higher than the day-time densities (Table 19). Over 70% of the taxa (44 of 60 taxa) had higher day-time densities with large day-night differences apparent for yolk-sac larval Ictiobinae, common carp, and Pimephales type that collectively accounted for 58% of the total night-time density (Table 19). Nearly all of the round goby were entrained at night. Three taxa, Cyprinidae yolk-sac larvae, eggs of common carp and eggs of freshwater drum, collectively comprised 56% of the total day-time density (Table 19). On a sampling event basis, the night-time densities were higher during 13 of the 16 sampling events (Table 20). Day-time densities were higher on three consecutive sampling event days between 3 June and 17 June largely because of higher day-time densities of Cyprinidae yolk-sac larvae and eggs of common carp and freshwater drum (Table 20). These three taxa had overall higher day-time densities for the full study.

3.2.5. Depth Distribution Ichthyoplankton densities during the entrainment study were 34% higher in the surface samples than in the near-bottom samples (Table 21). About 60% of the taxa (35 of 60 taxa) had higher surface densities with large depth differences apparent for Ictiobinae, Cyprinidae, and common carp yolk-sac larvae (Table 21). Densities were higher at the surface than near-bottom during 12 of the 16 sampling events when densities of Ictiobinae, common carp, and Cyprinidae life stages were highest (Table 22). Surface densities were less than twice as high as the near-bottom densities during most of the sampling events but were two or more times as high as the bottom densities in May and late June.

3.2.6. Seasonal Distribution The entrainment study documented that spawning for resident species in the Illinois River near the RSH occurs from April through August (Figure 3). A single freshwater drum egg occurred in the initial samples collected 3 April 2014 and 11 larvae were in. samples from the final sampling on 26 August 2014 (Table 22). The majority of ichthyoplankton were entrained at the RSH 3-5

between 11 May and 30 June, with a distinct May peak due to freshwater drum and common carp eggs (Figure 4). Ichthyoplankton abundance during that period primarily reflects the density of Ictiobinae, Cyprinidae, common carp, and Pimephales type larvae and eggs of freshwater drum and common carp; those taxa collectively accounted for 83% of the total estimated entrainmnent.

Estimated entrainment numbers ranged from 12,950 during the 30 March - 16 April extrapolation period to 13.2 million during the 11-17 May extrapolation period (Figure 3), when an estimated 6.9 million Ictiobinae larvae and 3.4 million common carp larvae dominated the entrainment samples (Figure 4). Estimates from late May through June varied from 2.6 to 5.3 million per extrapolation period. Jchthyoplankton abundance declined rapidly after 30 June as only 111,111 was estimated for the final 17-30 August extrapolation period. Overall, 88% of the estimated entrainment at the RSH occurred between 11 May and 30 June 2014.

3.2.7. Entrainment Estimate The RSH entrainment study was based on extrapolating results from 16 entrainment sampling events conducted between 30 March and 30 August 2014. Ichthyoplankton densities were estimated based on the MW volumes pumped during weekly/biweekly periods. The estimates were then summed to yield annual entrainment estimates by taxa. The resulting annual estimate for total number of ichthyoplankton entrained at the RSFI was 38.1 million fish eggs and larvae (Table 23). Six taxa accounted for 83% of the entrainment estimate; larval Cyprinidae, common carp, Pimnephales type, other Cyprinidae, and freshwater drum and common carp eggs. Only four other taxa/life stages accounted for more than 1% of the total estimate. Entrained sportfish taxa (channel catfish, Morone, all centrarchid taxa, Sander, walleye, and freshwater drum) comprised 10% of the total estimate of which 66% were freshwater drum eggs. Overall, fish eggs accounted for 14% of the total estimate and yolk-sac larvae accounted for 76% of the total estimate.

Juveniles accounted for 3% of the total entrainment estimate. Two invasive species (common carp and round goby) comprised 20% of the total entrainment estimate. Exclusion of invasive fish taxa estimates from the annual estimate lowers the total number of ichthyoplankton entrained from 38.1 million to 30.3 million.

The RSH entrainment estimate reflects the abundance of early life stages of primarily minnows, the introduced common carp, and freshwater drum eggs. Entrained taxa generally have high fecundity and extended spawning seasons. The overall low relative abundance of species that build nests and/or provide, parental care (e.g., catfish, bass, and sunfishes) is typic~tl for entrainment estimates at power plant intakes. Low numbers of these species reflects spawning and life development characteristics that reduce susceptibility to entrainment. The life history of fishes is important in determining the extent to which they are at risk to entrainment. Like nest builders and species providing parental care, cover orientated species (i.e., species with demersal and/or adhesive eggs) are at less risk. Conversely, species with a pelagic lifestyle (i.e., those with buoyant, semi-buoyant, or non-adhesive eggs) are at greater risk. Most freshwater fishes have low risk lifestyles or spawning strategies.

3-6

4. DISCUSSION 4.1. IMPINGEMENT Results of the impingement study indicated that primarily forage fish and introduced species with high reproductive potentials, high natural mortality rates, and low economic value were impinged. The dominance of forage fish taxa in the total impingement estimate coupled with low contributions of sportfish to the estimate suggest that impacts to the fishery in the Marseilles Pool of the Illinois River from LSCS operations are likely low.

The volume of water drawn through the LSCS RSH, which serves as makeup to a closed cycle cooling system, and associated rates of impingement and entrainment are substantially less than for open cycle generating stations that withdraw their entire cooling volume from a lake or river.

In order to provide additional perspective, LSCS impingement and entrainment rates were compared to two open cycle stations and one dual mode station within the Upper Illinois Waterway and Illinois River Basin. The three stations include two NRG/Midwest Generation facilities, Will County and Joliet 29 Stations, as well as Exelon's Dresden Nuclear Station.

Station Intake and Discharge Waterbody River Mile Will County Chicago Sanitary and Ship Canal 295.4 Joliet 29 Des Plaines River 284.6 Dresden Kankakee and Illinois Rivers 272.3 LaS alle Illinois River 249.5 Table 24 summarizes impingement and entrainment results from each of the four stations. The Joliet 29 and Dresden studies were each conducted over two years while the Will County study, like LSCS, was a one year study. Will County and Joliet 29 are open cycle cooling stations, whereas Dresden operates under one of two modes of cooling depending on the time of year.

From 15 June to 30 September (3.5 months), Dresden operates in an indirect-open cycle mode, where water is drawn in through the circulating water intake structure on the Kankakee River, conveyed to the condensers, and cycled through the Dresden cooling pond before being discharged into the Illinois River. The remainder of the year (8.5 months), Dresden operates its cooling pond in a closed cycle, similar to LSCS.

In terms of water withdrawal, makeup water from the Illinois River for LSCS (86 to 88 mgd) represents six to 10 percent of the daily cooling water volume withdrawn for the two open cycle stations (Table 1). This is also true for Dresden Nuclear Station during the limited time that it operates in indirect-open cycle each year. Similarly, LSCS 12-month impingement estimates ranged from one to 25 percent of the 12-month impingement estimates observed at the two up stream open cycle stations and at Dresden during its 3.5 months of indirect-open cycle operations. Impingement at LSCS was 75 to 99 percent lower than impingement during open cycle operation at the three upstream facilities. Those differences are consistent with U.S. EPA's projections that best available technology for existing facilities (e.g., use of closed cycle cooling systems) could reduce impingement losses by 95 percent (FR 2014).

4-1

4.2. ENTRAINMENT Results of the LSCS RSH entrainment characterization study indicated that ichthyoplankton impacted by entrainment represented primarily forage fish that have high reproductive potentials, high natural mortality rates, and low economic value. The dominance of forage fish taxa coupled with low contributions of sportfish to the total entrainment estimate suggest that impacts to the Marseilles Pool of the Illinois River from operating the LSCS are likely low.

The estimated number of ichthyoplankton entrained at the RSH was also low compared to the two open cycle and one dual mode generating stations described in the above impingement comparison. The RSH 12-month entrainment estimates ranged from 14% to 43% of the 12-month entrainment estimates for the three upstream stations (Table 24). In other words, entrainment at the closed cycle LSCS was 57 to 86 percent lower than entrainment during open cycle operation at the other Illinois plants. Those differences are consistent with U.S. EPA's projections that best available technology for existing facilities (e.g., use of closed cycle cooling systems) could reduce entrainment losses by 90% (FR 2014).

4-2

5. REFERENCES Auer, N.A. (editor). 1982. Identification of larval fishes of the Great Lakes basin with emphasis on the Lake Michigan drainage. Great Lakes Fishery Commission. Special Publication 82-3. Ann Arbor, Michigan. 744 pp.

Bosley, T.R. and J.V. Connor. 1984. Geographic and temporal variation in numbers of myomeres in fish larvae from the lower Mississippi River. Trans. Amer. Soc. 113:238-242.

Federal Register (FR). 2014. National Pollutant Discharge Elimination System--Final Regulations To Establish Requirements for Cooling Water Intake Structures at Existing Facilities and Amend Requirements at Phase I Facilities. Volume 79 (158); 48300-48439.

Gablehouse, D. W. 1984. A Length-Categorization System to Access Fish Stocks. North American Journal of Fisheries Management 4:273-1984.

Illinois Endangered Species Protection Board. 2015.

http://www.dnr.illinois.gov/ESPB/Documents/20 15 ChecklistFINAL for webpage_05191 5._p~df Kay, L.K., R. Wallus, and B.L. Yeager. 1994. Reproductive biology and early life history of fishes in the Ohio River drainage. Volume 2: Catostomidae. Tennessee Valley Authority, Chattanooga, Tennessee, USA.

Simon, T.P. and R. Wallus. 2003. Reproductive Biology and Early Life History of Fishes in the Ohio River Drainage. Volume 3: Ictaluridae - Catfish and Madtoms. CRC Press, Boca Raton, Florida.

_________2006.

Reproductive Biology and Early Life History of Fishes in the Ohio River Drainage. Volume 4: Percidae - Perch, Pikeperch, and Darters. CRC Press, Boca Raton, Florida.

U.S. Fish and Wildlife Service. 2015. http://www.fws.gov/midwest/endangered~lists/illinois-cty.htinl.

Wallus, R. and T.P. Simon. 2006. Reproductive Biology and Early Life History of Fishes in the Ohio River Drainage. Volume 5: Aphredoderidae through Cottidae, Moronidae, and Sciaenidae. CRC Press, Boca Raton, Florida.

_________2008.

Reproductive Biology and Early Life History of Fishes in the Ohio River Drainage. Volume 6: Elassomatidae and Centrarchidae. CRC Press, Boca Raton, Florida.

5-1

Wallus, R., T.P. Simon, and B.L. Yeager. 1990. Reproductive Biology and Early Life History of Fishes in the Ohio River Drainage. Volume 1: Acipenseridae through Esocidae.

Tennessee Valley Authority, Chattanooga, Tennessee.

5-2

FIGURES

Figure 1. Site of LaSalle County Station River Screen House (RSH).

Source: (ioogle

Figure 2 -Impingement Estimate by Extrapolation Period at LaSalle County Station, April 2014 through March 2015 2000 1800 1600 1400 1200 1000 800 600 400-200-0-

I U-I

.~l.

.~J UI Total Impingement

-4 0.

(N

'-4

-4 0

-4 0.

(N en

-4

-4 0.

<N 3

-4 Cu r'J

-4

-4 4

.~J.

-4 C

3 0

Cu LA (N

-4 C

3

-4 (N

00 0

6

-4

3 LA 0

C

3 (N

(N

-4

-4 0

-4

3 (N

0

3 0(N

-4 00

3

-4 en 0

10

-4 00

3 0en

-4 11

-4a.

0)

LA en

-4 00

3

-4 en 12

.~1.

-4

(~1 0

LA (Na 0)

LA

-4 13

-4 U0) 0

'.0 0

U 0

'.0 (N

14

-4 U

0)0 0

(N 0

15 LA

-4 C

Cu 0-4 U

0)0

-4 (N

16 LA

-4 C

Cu

-4en

-4

-4 17 U~)

-4

.0 0)

U-LA (N

-4 0

18 LA

-4 Cu

-4 (N

-o 0)

U-

'.0 (N

19 LA

-4 Cu

-4 en (N

(N 20 1

2 5

7 8

9

Figure 3. Estimated Entrainment of Ichthyoplankton for Each Extrapolation Period at LaSalle County Station, 30 March - 30 August 2014.

14 13 12 11 1o o 0 I-4-

I-0 90 E6

.6Q E

w 3

2 1

--4--Total Fish Eggs Total Fish Larvae -h-Total Ichthyoplankton~

0 0.

(0 C.

03 L--

o3 a'-

a)

C-r'-

1~

(N (0

Extrapolation Period 04 (NI U) 0)

(N (0

0 Cv-0 (N

Figure 4. Estimated Entrainment of Dominant Ichthyoplankton Taxa for Each Extrapolation Period at LaSalle County Station, 30 March - 30 August 2014.

14 13 12 11 10 C

o9 0

0 0

0 L.

0o E

=

5 2

I 0

UI Freshwater Drum Eggs E1Pimephales type Larvae

  • J Ictiobinae Larvae U Common Carp Eggs U Common Carp Larvae

[] Other Larvae BOther Fish Eggs mOther Cyprinidae Larvae I

N1 C

1-U4 0

N

~YA C',

03 o?,

r--

{0

,<j.

t',

N-N-

T-N Extrapolation Period a,

04 Nq iii N4 0)

(0 "N

")

(0 Ca 03 N-

TABLES

Table 1.

Summary of Makeup Water Withdrawal during Impingement Sampling and Extrapolation Periods, LaSalle County Station River Screen House, April 2014 through March 2015 Data for lmpingment Sampling Events Extrapolation Data SamI Period Volume (a)

Period Volumeib)

Durati 01-12 Apr 14 1,037 02-03 Apr 14 86.4 24 13-26 Apr 14 1,210 14-15 Apr 14 86.4 24 27 Apr-10 May 14 1,210 30 Apr-01 May 14 86.0 23 11-24 May 14 1,210 12-13 May 14 86.5 24 25 May-07 Jun 14 1,210 27-28 May 14 86.5 24 08-21 Jun 14 1,210 10-11 Jun 14 86.4 24 22 Jun-05 Jul 14 1,210 24-25 Jun 14 86.4 24 06-19 Jul 14 1,210 07-08 Jul 14 85.9 23 20 Jul-02 Aug 14 1,210 28-29 Jul 14 86.1 23 03-16 Aug 14 1,210 11-12 Aug 14 86.4 24 17-30 Aug 14 1,210 25-26 Aug 14 86.8 24 31 Aug-13 Sep 14 1,210 07-08 Sep 14 87.3 24 14 Sep-25 Oct 14 1,987 22-23 Sep 14 89.1 24 26 Oct-06 Dec 14 1,598 24-25 Nov 14 86.6 24 07-20 Dec 14 1,210 15-16 Dec 14 87.1 24 21 Dec-10 Jan 15 1,642 22-23 Dec 14 86.4 24 11-3 1 Jan 15 1,728 26-27 Jan 15 85.9 23 01-25 Feb 15 1,814 09-10 Feb 15 86.8 24 26 Feb-21 Mar 15 1,728 16-17 Mar 15 86.5 24 22-3 1 Mar 15 864 30-31 Mar 15 86.3 24 (a) Total makeup water volume, in millions of gallons, for each extrapolation period based on actual usage.

(b) Total sample volume, in millions of gallons for each 24-hour sampling period.

(ci Total sampling duration (hours) for each 24-hour sampling period.

pie onici

.9 3.9

'..O

  • .3 1..0 3.9

Table 2. Summary of Makeup Water Withdrawal during Entrainment Sampling and Extrapolation Periods LaSalle County Station River Screen House, April - August 2014.

Data for Entrainment Sampling Events Extrapolation Data Sample No. Makeup Volume(c)

Pumps Period Volume~a)

No. of Daysm*~ Event 30 March-i16 April 1,555.2 18 3 April 17 April-03 May 1,468.8 17 24 April 4-10 May 604.8 7

6 May 11-17 May 604.8 7

13 May 18-24 May 604.8 7

20 May 25-31 May 604.8 7

28 May 1-7 June 604.8 7

3 June 8-14 June 604.8 7

11iJune 15-21 June 604.8 7

17 June 22-30 June 777.6 9

24 June 1-12 July 1,036.8 12 9 July 13-19 July 604.8 7

15 July 20-26 July 604.8 7

22 July 27 July-2 August 604.8 7

29 July 3-16 August 1,209.6 14 12 August 17-30 August 1,209.6 14 26 August (a) Total makeup water volume, in millions of gallons, for each extra (b) Number of days within extrapolation period.

(c) Total sample volume, in millions of gallons, for each event.

(d Makeup water pumping rate (MGD) during each sampling event.

0.120 0.127 0.134 0.121 0.142 0.115 0.116 0.116 0.111 0.12 1 0.125 0.120 0.116 0.140 0.117 0.120

]polation period.

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

Flow(d) 86.4 86.4 86.4 86.4 86.4 86.4 86.4 86.4 86.4 86.4 86.4 86.4 86.4 86.4 86.4 86.4

Table 3. Water Temperatures Recorded during Impingement Sampling Events, LaSalle County Station River Screen House, April 2014 through March 2015.

Intake Dissolved Temperature (C)

Oxygen (mg/L)

Period Min.

Mean Max.

Min.

Mean Max.

02-03 Apr 14 9.0 9.4 9.8 10.8 11.3 11.8 14-15 Apr 14 12.4 13.9 14.7 9.1 9.9 10.8 30 Apr-01 May 14 14.3 14.7 15.1 8.4 9.3 9.9 12-13 May 14 19.8 20.8 21.5 7.0 7.8 9.1 27-28 May 14 22.7 23.8 24.5 6.2 7.3 8.1 10-11 Jun 14 21.6 23.1 24.6 7.6 8.7 11.3 24-25 Jun 14 24.5 25.2 26.0 07-08 Jul 14 24.6 25.7 26.6 7.5 7.9 8.2 28-29 Jul 14 26.2 26.9 27.3 11-12 Aug 14 27.2 27.6 28.0 7.0 7.7 8.5 25-26 Aug 14 25.7 26.8 27.6 6.3 7.0 7.2 07-08 Sep 14 25.8 26.3 26.7 6.9 7.2 7.6 22-23 Sep 14 20.1 20.6 21.0 8.3 8.7 9.2 24-25 Nov 14 4.4 5.6 7.3 11.5 12.3 13.2 15-16 Dec 14 6.0 6.5 6.8 22-23 Dec 14 4.9 5.6 6.8 26-27 Jan 15 1.6 1.8 2.2 13.9 14.3 14.4 09-10 Feb 15 3.3 3.7 4.0 13.8 14.0 14.4 16-17 Mar 15 8.1 9.1 9.9 11.6 11.9 12.1 30-31 Mar 15 7.2 8.2 9.2 12.6 13.2 13.5

Table 4. Family, Common, and Scientific Names of Crayfish, Mussels, and Fishes Collec*ted During Impingement Sampling at the LaSalle County Station River Screen House, April 2014 througqh March 2015.

Family Name Freshwater Crayfishes Freshwater Mussels Common Name Orconectes Northern Clearwater Procambarus Fragile Papershell Pink Heelsplitter Paper Pondshell Scientific Name(11 Orconectes sp.

Orconectes prop/n quus Procamnbarus sp.

Lep todea frag//is Potamilus alatus Utterbackia imbecil/is Freshwater Eels Herrings Pikes And Mudminnows Carps And Minnows American Eel Gizzard Shad Threadfin Shad121 Dorosoma Central Mudminnow Grass Pickerel Goldfish' 2' Common Ca rp'21 Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottall Shiner Silverband Shiner Spotfin Shiner Notropis Bluntnosa Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae White Sucker Smailmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish' 2' An gui//a rostrata Dorasoma cepedionum Dorosoma petenense Darosoma sp.

Suckers Loaches Umbra limi Esax americanus vermiculatus Carassius auratus Cyprin us carpia Nacomis bigutratus Notemigonus crysoleucas Notropis otherinoides Luxilus chrysocephalus Natropis hudsonius Notropis shumardi Cyprinella spiloptera Notraopis sp.

Pimepha/es notatus Pimephales promelas Pimephales vigilax Sernot//us atromacu/atus Cyprinidae sp.

Catostamus commersonhi Ictiobus bubalus Moxostoma duquesnei Maxostoma erythrurum Misgurnus angui//icaudatus Ameiurus me/os Ameiurus nato/is Icta/urus punctatus Noturus nocturnus Pylodictis a//var/s Labidesthes sicculus Morane mississippiensis Lepamis cyanel/us Lepomis gulosus Lepamis humi/is Lepomis macrochirus Lepamis sp.

Micraopterus do/am/eu Micrap terus sa/moides Pamoxis nigromaculatus Etheostama zonale Sander vitreus Sander sp.

Ap/odinotus grunn/ens Neo gab/us melanastomus North American Catfishes New World Silversides Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtam Flathead Catfish Brook Silverside Temperate Basses Yellow Bass Sunfishes Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepamis Smallmouth Bass Largemouth Bass Black Crappie Perches and Darters Drums and Croakers Banded Darter Walleye Sander Freshwater Drum Round Goby'2' Gobies

'11Nomenclature follows Nelson et al. 2004.

(2)lntroduced/lnvasive species.

Table 5. Number and Biomass of Crayfish, Mussels, and Fish Collected During Impingement Sam at LaSalle County Station River Screen House, April 2014 through March 2015.

Impingement Study Totals Number Caught Weight Caught Common Name No.

KG Orconectes sp.

1 11.11%

0.003 7.89%

Northern Clearwater Crayfish 7

77.78%

0.035 92.11%

Procambarus sp.

1 11.11%

Total Crayfish 9 100.00%

0.038 100.00%

Total Crayfish Species 2

Fragile Papershell 2

22.22%

0.003 17.65%

Pink Heelsplitter 1

11.11%

0.001 5.88%

Paper Pondshell 6

66.67%

0.013 76.47%

Total Mussels 9 100.00%

0.017 100.00%

Total Mussel Species 3

American Eel 1

0.16%

0.746 8.36%

Gizzard Shad 185 29.13%

1.614 18.09%

Threadfin Shad(11 59 9.29%

0.172 1.93%

Dorosoma sp.

16 2.52%

0.027 0.30%

Central Mudminnow 10 1.57%

0.050 0.56%

Grass Pickerel 1

0.16%

0.008 0.09%

Goldfish(11 29 4.57%

0.173 1.94%

Common Carp(11 12 1.89%

0.832 9.32%

Hornyhead Chub 1

0.16%

0.089 1.00%

Golden Shiner 2

0.31%

0.011 0.12%

Emerald Shiner 4

0.63%

0.016 0.18%

Striped Shiner 2

0.31%

0.032 0.36%

Spottail Shiner 12 1.89%

0.068 0.76%

Silverband Shiner 1

0.16%

0.003 0.03%

Spotfin Shiner 6

0.94%

0.020 0.22%

Notropis sp.

1 0.16%

0.001 0.01%

Bluntnose Minnow 33 5.20%

0.092 1.03%

Fathead Minnow 2

0.31%

0.009 0.10%

Bullhead Minnow 13 2.05%

0.042 0.47%

Creek Chub 6

0.94%

0.022 0.25%

Cyprinidae sp.

1 0.16%

0.001 0.01%

White Sucker 5

0.79%

0.038 0.43%

Smalimouth Buffalo 2

0.31%

1.268 14.21%

Black Redhorse 1

0.16%

0.023 0.26%

Golden Redhorse 2

0.31%

0.087 0.98%

Oriental Weatherfish111 2

0.31%

0.063 0.71%

Black Bullhead 9

1.42%

0.273 3.06%

Yellow Bullhead 1

0.16%

0.005 0.06%

Channel Catfish 10 1.57%

0.320 3.59%

Freckled Madtom 1

0.16%

0.003 0.03%

Flathead Catfish 2

0.31%

0.009 0.10%

Brook Silverside 1

0.16%

0.002 0.02%

Yellow Bass 3

0.47%

0.063 0.71%

Green Sunfish 20 3.15%

0.083 0.93%

Warmouth 1

0.16%

0.029 0.33%

Orangespotted Sunfish 5

0.79%

0.031 0.35%

Bluegill 41 6.46%

0.728 8.16%

Lepomis sp.

1 0.16%

0.002 0.02%

Smallmouth Bass 1

0.16%

0.204 2.29%

Largemouth Bass 7

1.10%

0.034 0.38%

Black Crappie 9

1.42%

0.037 0.41%

Banded Darter 1

0.16%

0.001 0.01%

Walleye 1

0.16%

0.382 4.28%

Sander sp.

1 0.16%

0.001 0.01%

Freshwater Drum 40 6.30%

0.717 8.04%

Round Goby{1 )

71 11.18%

0.492 5.51%

Total Fish 635 100.00%

8.923 100.00%

Total Fish Species 41 Total Organisms 653 Total Species 46 Notes: Frequency of occurrence based on 20 sampling events.

11) Introduced/Invasive species.

Freguency of Occurrence No.

1 5.0%

5 25.0%

1 5.0%

1 5.0%

1 5.0%

3 15.0%

1 5.0%

14 70.0%

8 40.0%

4 20.0%

2 10.0%

1 5.0%

4 20.0%

4 20.0%

1 5.0%

2 10.0%

3 15.0%

2 10.0%

4 20.0%

1 5.0%

4 20.0%

1 5.0%

4 20.0%

2 10.0%

3 15.0%

2 10.0%

1 5.0%

1 5.0%

2 10.0%

1 5.0%

2 10.0%

2 10.0%

4 20.0%

1 5.0%

7 35.0%

1 5.0%

2 10.0%

1 5.0%

3 15.0%

5 25.0%

1 5.0%

4 20.0%

14 70.0%

1 5.0%

1 5.0%

5 25.0%

3 15.0%

1 5.0%

1 5.0%

1 5.0%

7 35.0%

8 40.0%

Table 6. Total Length (mam) Data for Fish Impinged at LaSalle County Station River Screen House, April 2014 through March 2015.

Common Name American Eel Gizzard Shad Threadfin Shad Dorosoma Sp.

Central Mudmin now Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis Sp.

Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae Sp.

White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis Sp.

Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander Sp.

Freshwater Drum Round Goby

-- Indicates not measured.

Min Length 692 47 51 38 63 101 53 46 72 96 72 73 38 52 60 56 67 71 128 67 147 48 69 56 63 68 66 84 39 95 50 36 50 245 46 45 355 57 94 55 Max Length 692 183 108 71 83 101 93 399 98 96 72 91 38 61 60 61 Mean Length 692 91 65 53 74 101 70 109 85 96 72 82 38 57 60 58 99 423 128 180 179 163 69 293 63 84 66 143 99 95 83 161 50 245 83 89 355 57 167 97 85 247 128 124 163 112 69 128 63 76 66 104 54 95 66 81 50 245 67 65 355 57 119 79

Table 7. Monthly Length Frequency Distribution for Gizzard Shad Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

APR MAY JUN 2014 2014 2014 JUL 2014 AUG SEP 2014 2014 OCT 2014 NOV DEC 2014 2014 JAN FEB MAR 2015 2015 2015 Length (mm) 40 - 49 50 - 59 60 - 69 70 - 79 80 - 89 90 -99 100 - 109 110 -119 120 - 129 130 - 139 140 - 149 150 - 159 160 - 169 170 - 179 180 -189 Total 5

22 4

2 1

2 3

2 1

3 w.

0 1

1 1

4 12 12 10 1

1 41 6

8 9

3 3

2 31 1

1 2

1 1

1 1

4 33

Table 8. Monthly Length Frequency Distribution for Threadfin Shad Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

APR MAY 2014 2014 JUN 2014 JUL AUG 2014 2014 SEP 2014 OCT NOV DEC JAN FEB MAR 2014 2014 2014 2015 2015 2015 Leng~th (mm) 50 - 59 60 - 69 70 - 79 80 - 89 90 - 99 100 - 109 Total 3

9 3

3 3

9 11 8

2 1

1 32 I0)

.,I-ou 1

1 12 9

Table 9. Monthly Length Frequency Distribution for Bluegill Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

APR MAY JUN JUL AUG 2014 2014 2014 2014 2014 SEP OCT NOV DEC JAN FEB MAR 2014 2014 2014 2014 2015 2015 2015 Length (mm) 1 1

30 - 39 40 - 49 50 - 59 60 - 69 70 - 79 80 - 89 90 - 99 100 - 109 110 -119 120 -129 130 -139 140 - 149 150 -159 160 - 169 Total 1

1 1

1 1

5 2

1 1

1 1

1 1

1 1

1 1

1 2

0)

(U

  • 1-'0 1

1 1

1 2

1 1

1 1

4 2

1 1

1 5

4

Table 10. Monthly Length Frequency Distribution for Freshwater Drum Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

APR MAY JUN JUL AUG SEP OCT NOV Length(mm) 2014 2014 2014 2014 2014 2014 2014 2014 DEC JAN FEB MAR 2014 2015 2015 2015 r

r T

r T

r r

1 90 -99 100 - 109 110 -119 120 -129 130 -139 140 -149 150 -159 160 -169 Total 1

1 3

3 1

2 4

5 1

1 1

2 4

2 1

bfl

  • 0 2

1 1

2 1

14 ii 10 3

Table 11. Monthly Length Frequency Distribution for Round Goby Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

APR MAY JUN JUL AUG SEP OCT NOV DEC JAN FEB MAR Length (mm) 2014 2014 2014 2014 2014 2014 2014 2014 2014 2015 2015 2015 50 -59 1

60 -69 5

31 70 -79 14 6

1 1

80 -89 10 8

1 90 -99 2

7 Total 31 24 2

2 1

Table 12. Length Frequency Distribution for Five Abundant Species Impinged at LaSalle County Station River Screen House, April 2014 - March 2015.

Threadfin Shad Freshwater Drum Length (mm)

Gizzard Shad Bluegill Round Goby 30 -39 40-49 50 -59 60 -69 70-79 80 -89 90 -99 100 -109 110 -119 120 -129 130 -139 140 -149 150 -159 160 -169 170 -179 180 -189 5

26 9

5 5

24 24 21 5

4 2

1 18 26 8

2 1

2 2

6 8

6 3

3 1

1 3

3 3

1 1

1 9

22 19 9

59 10 5

5 3

2 1

1

Table 13. Comparison of Length Data for Sportfish Impinged at LaSalle County Station River Screen House to Stock and Quality Length Categories.t1 )

Length of Impinged Fish Species Black Bullhead Yellow Bullhead Channel Catfish Flathead Catfish Bluegill Smallmouth Bass Largemouth Bass Black Crappie Walleye Freshwater Drum N

9 1

10 2

41 1

7 9

1 40 Maximum 163 69 293 84 161 245 83 89 355 167 Average 112 69 128 76 81 245 67 65 355 119 Length Categories Stock Quality 122 218 81 147 239 432 224 401 76 137 137 246 165 297 102.

183 208 376 160 287 (1)Source for Stock and Quality Length Categories: Gablehouse 1984.

Table 14. Impingement Estimates at LaSalle County Station River Screen House, April 2014 through March 2015.

Common Name Estimated Count Estimated Weight (Kg)

Orconectes sp.

10 0.030 Northern Clearwater Crayfish 120 0.660 Procambarus sp.

14 Total Crayfish 144 0.690 Fragile Papershell 44 0.070 Pink Heelsplitter 14 0.010 Paper Pondshell 99 0.220 Total Mussels 157 0.300 American Eel 14 10.440 Gizzard Shad 3,245 29.650 Threadfin Shad1'1 985 3.020 Dorosoma sp.

242 0.430 Central Mudminnow 179 0.900 Grass Pickerel 14 0.110 Goldfish( 2) 577 3.430 Common Carp(2) 174 12.110 Hornyhead Chub 13 1.240 Golden Shiner 23 0.140 Emerald Shiner 59 0.240 Striped Shiner 26 0.450 Spottail Shiner 195 1.120 5ilverband Shiner 14 0.040 Spotfin Shiner 99 0.350 Notropis sp.

13 0.010 Bluntnose Minnow 459 1.290 Fathead Minnow 23 0.110 Bullhead Minnow 195 0.620 Creek Chub 91 0.350 CYPRINIDAE sp.

13 0.010 White Sucker 69 0.530 5malimouth Buffalo 28 23.340 Black Redhorse 20 0.460 Golden Redhorse 26 1.220 Oriental Weatherfish( 2 )

27 0.880 Black Bullhead 152 5.090 Yellow Bullhead 13 0.070 Channel Catfish 151 4.490 Freckled Madtom 18 0.060 Flathead Catfish 26 0.130 Brook Silverside 10 0.020 Yellow Bass 45 0.910 Green Sunfish 365 1.440 Warmd~uth 18 0.540 Orangespotted Sunfish 75 0.460 Bluegill 695 13.370 Lepomis sp.

14 0.030 5malimouth Bass 13 2.850 Largemouth Bass 111 0.580 Black Crappie 154 0.700 Banded Darter 13 0.010 Walleye 14 5.350 Sander sp.

14 0.010 Freshwater Drum 657 11.730 Round Goby(2) 991 6.890 Total Fish 10,372 147.220 Total Organisms 10,673 148.210 (1)Impingement estimates based on rated pump capacity.

(2) Introduced/invasive species.

Table 15. Water Temperatures Recorded during Entrainment Sampling Events, LaSalle County Station River Screen House, 3 April -- 26 August 2014.

Intake Temperature (C)

Period Minimum Mean Maximum 3 April 8.6 8.7 8.7 24 April 15.4 15.6 15.9 6 May 15.4 15.7 16.0 13 May 19.6 19.8 20.0 20 May 16.6 16.8 17.0 28 May 23.8 23.9 24.0 3 June 25.1 25.3 25.5 11 June 21.9 22.1 22.3 17 June 25.1 25.3 25.5 24 June 24.8 25.0 25.3 9 July 26.1 26.4 26.7 15 July 23.5 23.8 24.0 22 July 28.0 28.2 28.5 29 July 26.0 26.3 26.9 12 August 26.9 27.0 27.1 26 Aucqust 27.0 27.1 27.3

Table 16. Summary of Water Temperature, Dissolved Oxygen, and Current Velocity Measurements during Entrainment Sampling at LaSalle County Station River Screen House, 3 April - 26 August 2014.

Surface Bottom Sampling Diel Date Period 3 April

... Day

_Night 24 April

-Day

.*Night.;

6 May Day

  • -Nig t 13 May Day Night 20 May

.Day.

Night 28 May Day 3 June Day

_Ni ht_

11 June Da iNigh 17 June Day 24 June Day Niajght:,

9 July Day 15 Jul ight 225July Day Ni.Nght..

22 July Day NiNght..

12 August Day_

r_.Night'*

26 August Day Water Temperature 8.6 8.6 15.9 16.0 20.0 17.0....

24.0 25.5 22.3 25.5

...2-5.1 25.3 24.8,

26.7 24.0 28.5 26.9 27.1 27.3 Dissolved Oxygen (mg/L) 11.4 11

,**.:2,,

14.0 11.?

.5..

13.6

..-10.2: -

8.2 10.4 8.5 9.7 7.7 7.4 9.5 8.2 9.0

.:!81I.

7.6 10.5 11.0 7.6 7.1 7;

. 0.-X

--I...

Current Velocity (ftlsec) 1.5 1.6 0.9 1.4 1.4 1.0 1.3 1.7 1.7 1.3 185 101 106 1.0 1.3 1.6 1.4 Water Temperature 8.6 1548 15.9 19.9 16.9 24.0 9 5

25.1 22.1 21.9_

25.3 25-_.

.*i 1

25.1 24.8 26.1 23.9 28.3 26.4 27.1 27.1 i_26*-.9lL'I Dissolved Oxygen (mg/L) 11.4 12.9 1.2-i 13.6 10---o.2 8.2 9.8 8.5 9.7 7.8 7....

t 3......

9.5 8.2 S6.8 8.9 7.6 7

i.3its :)

10.4 10.6 7.9 6.9 Current Velocity (ft/sec) 1.3 135 1.5 1.3 1.5 1.5 1.57 137 1.4 1.5 1.5 1.4~

1.5 1.6 1.5 1.5 1.6 14....

Combined Day Min.

8.6 7.1 0.9 8.6 6.9 1.3 Mean 22.5 9.6 1.3 22.4 9.5 1.5 Max.

28.5 14.0 1.7 28.3 13.6 1.7 Combined Night.

SMinm...

8.6,"

6.8~

0.9 '

":8.7 "6.8, 1.;I:3 iMean 22.1 8.6,,.

.. 1.4

,:22.1 "

8.6

, - 1.5.,

,Max.

28.1 1.1.5 1.8 28.0 11.2 1,7

Table 17. Number and Relative Abundance of lchthyoplankton Taxa Collected during Entrainment Sampling at LaSalle County Station River Screen House, 3 April - 26 August 2014.

Common Occurrence( 3 )

Family Name Taxa Life Stage No.

No.

GARS GARsp.(1 )

Post Yolk-sac 3

0.04 2

13%

HERRINGS Dorosoma sp.

Yolk-sac 19 0.27 4

25%

Post Yolk-sac 230 3.23 12 75%

GIZZARD SHAD(11 Juvenile 5

0.07 3

19%

CARPS and MINNOWS CYPRIN]DAE sp.

Egg 22 0.31 1

6%

Yolk-sac 1,618 22.74 13 81%

Post Yolk-sac 25 0.35 2

13%

COMMON CARP111 Egg 431 6.06 8

50%

Yolk-sac 895 12.58 10 63%

Post Yolk-sac 2

0.03 2

13%

Juvenile 1

0.01 1

6%

Hypophthalmichthys type(11 Egg 35 0.49 3

19%

Notropis sp.(1)

Juvenile 4

0.06 1

6%

Pimephales sp.

Juvenile 1

0.01 1

6%

BLUNTNOSE MINNOW111 Post Yolk-sac 1

0.01 1

6%

Juvenile 4

0.06 2

13%

BULLHEAD MINNOW111 Juvenile 2

0.03 1

6%

Pimephales type(11 Yolk-sac 693 9.74 10 63%

Post Yolk-sac 4

0.06 2

13%

Semotilus type111 Yolk-sac 32 0.45 3

19%

Post Yolk-sac 8

0.11 2

13%

SUCKERS CATOSTOMIDAE sp.

Yolk-sac 4

0.06 2

13%

ICTIOBINAE sp.(21 Yolk-sac 1,750 24.60 10 63%

Post Yolk-sac 52 0.73 5

31%

Juvenile 2

0.03 1

6%

Moxostoma sp.{1 )

Yolk-sac 28 0.39 2

13%

Post Yolk-sac 19 0.27 6

38%

NORTH AMERICAN CATFISHES CHANNEL CATFISH111 Juvenile 16 0.22 2

13%

NEW WORLD SILVERSIDES BROOK SILVERSIDE111 Yolk-sac 2

0.03 1

6%

TOPMINNOWS BLACKSTRIPE TOPMINNOW(11 Yolk-sac 1

0.01 1

6%

Juvenile 1

0.01 1

6%

BANDED KILLiFISH(11 Juvenile 1

0.01 1

6%

TEMPERATE BASSES Morone sp.(1)

Yolk-sac 7

0.10 3

19%

SUNFISHES ROCK BASS(11 Post Yolk-sac 2

0.03 1

6%

Lepomis sp.

Yolk-sac 1

0.01 1

6%

Post Yolk-sac 8

0.11 5

31%

Juvenile 19 0.27 1

6%

GREEN SUNFISH(11 Juvenile 1

0.01 1

6%

PUMPKINSEED type(11 Yolk-sac 44 0.62 9

56%

Post Yolk-sac 6

0.08 4

25%

Juvenile 2

0.03 1

6%

BLUEGILL type111 Post Yolk-sac 3

0.04 1

6%

LARGEMOUTH BASS(11 Juvenile 1

0.01 1

6%

PERCHES AND DARTERS DARTER sp.(1 )

Yolk-sac 125 1.76 8

50%

Post Yolk-sac 30 0.42 7

44%

Juvenile 2

0.03 1

6%

LOGPERCH type111 Yolk-sac 166 2.33 11 69%

Post Yolk-sac 2

0.03 1

6%

Sander sp.

Yolk-sac 40 0.56 5

31%

Post Yolk-sac 1

0.01 1

6%

WALLEYE111 Post Yolk-sac 1

0.01 1

6%

DRUMS AND CROAKERS FRESHWATER DRUM111 Egg 480 6.75 10 63%

Yolk-sac 15 0.21 6

38%

Post Yolk-sac 20 0.28 3

19%

Juvenile 1

0.01 1

6%

GOBIES ROUND GOBY(1 )

Juvenile 147 2.07 7

44%

UNIDENTIFIED UNIDENTIFIED Egg 42 0.59 4

25%

Yolk-sac 26 0.37 9

56%

Larvae 2

0.03 1

6%

MoronelIPornoxis type Egg 9

0.13 2

13%

TOTAL ICHTHYOPLANKTON 7,114 100.00 TOTAL TAXA 27

11) Counted as one taxa.

121 Counted as two taxa.

13 1Occurences based on 16 sampling events.

Table 18.

Fish Larvae Length and Fish Egg Diameter (millimeters)

Statistics for Ichthyoplankton From Entrainment Samples Collected at LaSalle County Station River Screen House, 3 April -

26 August 2014.

Minimum Length!

LIFE STAGE Diameter TAXA GAR ap.

GIZZARD SHAD Dorosoma sp.

Dorosoma sp.

COMMON CARP COMMON CARP COMMON CARP COMMON CARP Hypophtbalmichthys type Notropis ap.

BLUMTNOSE MINNOW BLUNTNOSE MINNOW BULLHEAD MINNOW Pimephales type Pimephales type Pimephales ap.

Semotilus type Semotilus type CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

Moxostoma sp.

Moxostoma sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIDBINAE sp.

CATOSTOMIDAE sp.

CHANNEL CATFISH BANDED KILLIFISH BLACKSTRIPE TOPMINNOW BLACKSTRI PE TOPMINNOW BROOK SILVERSIDE Morone ap.

ROCK BASS GREEN SUNFISH BLUEGILL type PUMPKINSEED type PUMPKINSEED type PUMPKINSEED type Lepomis sp.

Lepomis sp.

Lepomis ap.

LARGEMOUTH BASS WALLEYE Post Yolk-sac Juvenile Yolk-sac Post Yolk-sac Egg Yolk-sac Post Yolk-sac Juvenile Egg Juvenile Post Yolk-sac Juvenile Juvenile Yolk-sac Post Yolk-sac Juvenile Yolk-sac Post Yolk-sac Egg Yolk-sac Post Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Post Yolk-sac Juvenile Yolk-sac Juvenile Juvenile Yolk-sac Juvenile Yolk-sac Yolk-sac Post Yolk-sac Juvenile Post Yolk-sac Yolk-sac Post Yolk-sac Juvenile Yolk-sac Post Yolk-sac Juvenile Juvenile Post Yolk-sac 25.2 18.7 3.7 4.3 1.0 1.0 9.3 29.0 2.1 11.7 16.6 13.4 12.2 3.8 6.0 9.8 6.4 7.9 i.i 1.2 5.0 10.7 12.2 5.7 7.9 19.8 3.6 10.2 17.5 6.1 10.2 5.2 2.7 7.5 15.2 5.3 3.7 7.2 13.8 5.5 6.1 9.6 35.5 15.1 Mean Length!

Diameter 25.8 24.2 6.2 8.6 1.4 6.7 11.6 29.0 3.8 13.9 16.6 18.0 18.7 5.6 8.1 9.8 8.5 10.1 1.6 4.2 7.9 13.3 14.0 7.5 10.0 22.2 4.8 14.8 17.5 6.1 10.2 5.4 2.9 8.9 15.2 5.5 5.2 8.5 14.3 5.5 9.5 13.7 35.5 15.1 Maximum Length/

Diameter 26.1 36.0 8.6 17.2 1.9 8.8 13.8 29.0 4.8 18.3 16.6 24.1 25.1 7.0 10.4 9.8 10.0 12.7 2.0 8.7 13.6 14.4 17.0 10.1 20.2 24.5 5.5 18.7 17.5 6.1 10.2 5.6 3.2 10.3 15.2 5.7 6.7 10.0 14.7 5.5 15.6 18.3 35.5 15.1

Table 18 (cant.)

TRXA Sander sp.

Sander sp.

LOUPERCE type LOGPERCH type DARTER sp.

DARTER sp.

DARTER sp.

FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM RouND GOBY Moronle/Pomoxis type UNIDENTIFIED UNIDENTIFIED UNIDENTIFIED LIFE STAGE Yolk-sac Post Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Past Yolk-sac Juvenile Egg Yolk-sac Post Yolk-sac Juvenile Juvenile Egg Egg Yolk-sac Larvae Minimum Length/

Diamneter 5.1 10.0 4.0 9.8 4.9 6.9 13.1 0.8 2.5 4.8 26.1 6.5 0.7 0.9 1.9 2.6 Mean Length/

Diameter 8.2 10.0 6.2 10.0 7.2 1i.i 13.4 1.4 4.1 8.5 26.1 7.9 0.9 1.3 4.4 2.6 Maximum Length/

Diameter 10.3 10.0 9.0 10.2 10.2 16.5 13.7 2.1 6.6 15.8 26.1 21.5 1.1 1.8 7.1 2.6

Table 19. Diel Comparisons of the Number, Density, and Relative Abundance of lchthyoplankton Collected during All Entrainment Sampling Events at LaSalle County Station River Screen House, 3 April -26 August 2014.

Day Night No.

Den.

%___ No.

Den.

Taxa GAR sp.

GIZZARD SHAD Dorosoma sp.

COMMON CARP Hypophthaimichthys type Notropis sp.

BLUNTNOSE MINNOW Life Stage Post Yolk-sac Juvenile Yolk-sac Post Yolk-sac Egg Yolk-sac Post Yolk-sac Juvenile Egg Juvenile Post Yolk-sac Juvenile BULLHEAD MINNOW Juvenile Pimephales type Yolk-sac Post Yolk-sac Pimephales sp.

Juvenile Semotilus type Yolk-sac Post Yolk-sac CYPRINIDAE sp.

Egg Yolk-sac Post Yolk-sac Moxostoma sp.

Yolk-sac Post Yolk-sac ICTIOBINAE sp.

Yolk-sac Post Yolk-sac Juvenile CATOSTOMIDAE sp.

Yolk-sac CHANNEL CATFISH Juvenile BANDED KILLIFISH Juvenile BLACKSTRIPE TOPMINNOW Yolk-sac Juvenile BROOK SILVERSIDE Yolk-sac Morone sp.

Yolk-sac ROCK BASS Post Yolk-sac GREEN SUNFISH Juvenile BLUEGILL type Post Yolk-sac PUMPKINSEED type Yolk-sac Post Yolk-sac Juvenile Lepomis sp, Yolk-sac Post Yolk-sac Juvenile LARGEMOUTH BASS Juvenile WALLEYE Post Yolk-sac Sander sp.

Yolk-sac Post Yolk-sac LOGPERCH type Yolk-sac Post Yolk-sac DARTER sp.

Yolk-sac Post Yolk-sac Juvenile FRESHWATER DRUM Egg Yolk-sac Post Yolk-sac Juvenile ROUND GOBY Juvenile MoronelIPomoxis type Egg UNIDENTIFIED Egg Yolk-sac Larvae TOTAL ICHTHYOPLANKTON Note: Density (Den.) is No. per million gallons.

18 111 319 228 24 169 2

7 22 982 11 2

4 429 6

4 6

12 12 1~

63 2

37 10 286 8

2 2

19 11 1.0 0.04 1.0 0.04 18.5 0.64 114.3 3.95 328.5 11.35 234.8 8.11 1.0 0.04 24.7 0.85 1.0 0.04 174.0 6.01 2.1 0.07 7.2 0.25 22.7 0.78 1,011.2 34.95 11.3 0.39 2.1 0.07 4.1 0.14 441.8 15.27 6.2 0.21 4.1 0.14 1.0 0.04 6.2 0.21 1.0 0.04 12.4 0.43 1.0 0.04 3.1 0.11 2.1 0.07 1.0 0.04 64.9 2.24 2.1 0.07 38.1 1.32 10.3 0.36 294.5 10.18 8.2 0.28 2.1 0.07 1.0 0.04 2.1 0.07 19.6 0.68 11.3 0.39 2

4 1

119 112 667 1

1 11 3

1 4

2 524 2

1 25 8

636 14 26 15 1,321 46 2

16 1

1 2

1 1

1 3

32 6

2 5

19 1

1 38 103 88 20 2

194 7

18 1

146 7

23 15 2

2.0 0.05 4.0 0.09 1.0 0.02 120.1 2.76 113.0 2.60 672.9 15.50 1.0 0.02 1.0 0.02 11.1 0.26 3.0 0.07 1.0 0.02 4.0 0.09 2.0 0.05 528.6 12.17 2.0 0.05 1.0 0.02 25.2 0.58 8.1 0.19 641.6 14.78 14.1 0.33 26.2 0.60 15.1 0.35 1,332.7 30.69 46.4 1.07 2.0 0.05 16.1 0.37 1.0 0.02 1.0 0.02 2.0 0.05 1.0 0.02 1.0 0.02 1.0 0.02 3.0 0.07 32.3 0.74 6.1 0.14 2.0 0.05 5.0 0.12 19.2 0.44 1.0 0.02 1.0 0.02 38.3 0.88 103.9 2.39 88.8 2.04 20.2 0.46 2.0 0.05 195.7 4.51 7.1 0.16 18.2 0.42 1.0 0.02 147.3 3.39 7.1 0.16 23.2 0.53 15.1 0.35 2.0 0.05 4,342.1 100.00 2,810 2,893.6 100.00 4,304

Table 20. Diel Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Each Entrainment Sampling Event at LaSalle County Station River Screen House, 3 April - 26 August 2014.

3 April Day Night Taxa Life Stage No.

Den.

%____ No.

Den.

FRESHWATER DRUM Egg 1

16.0 100.00 24 April Day Night Taxa Life Stage No.

Den.

%____ No.

Den.

Dorosoma sp.

Post Yolk-sac 3

46.2 14.29 ICTIOBINAE sp.

Yolk-sac 1

16.1I 2.5 Morone sp.

Yolk-sac 4

61.6 19.05 1

16.1 2.5 Sander sp.

Yolk-sac 27 433.8 67.5 LOGPERCH type Yolk-sac 13 200.3 61.9 10 160.7 25 UNIDENTIFIED Yolk-sac 1

15.4 4.76 1

16.1 2.5 TOTAL ICHTHYOPLANKTON 21 323.6 100.00 40 642.7 100.00 6 May Day Night Taxa Life Stagle No.

Den.

%____ No.

Den.

Dorosoma sp.

Yolk-sac 1

16.4 1.47 Post Yolk-sac 7

95.5 35.00 ICTIOBINAE sp.

Yolk-sac 7

95.5 35.00 62 1,015.2 91.18 Morone sp.

Yolk-sac 1

13.6 5.00 Sander sp.

Yolk-sac 1

13.6 5.00 1

16.4 1.47 LOGPERCH type Yolk-sac 4

54.6 20.00 UNIDENTIFIED Yolk-sac 4

65.5 5.88 TOTAL ICHTHYOPLANKTON 20 272.8 100.00 68 1,113.5 100.00 13 May Day Night Taxa Life Stage No.

Den.

%____ No.

Den.

Dorosoma sp.

Post Yolk-sac 7

118.6 0.98 6

97.4 0.31 COMMON CARP Egg 5

84.7 0.70 7

113.6 0.37 Yolk-sac 187 3,169.6 26.15 490 7,950.4 25.67 Semotilus type "Yolk-sac 6

101.7 0.84 20 324.5 1.05 CYPRINIDAE sp.

Yolk-sac 12 203.4 1.68 133 2,158.0 6.97 Moxostoma sp.

Yolk-sac 1

16.9 0.14 10 162.3 0.52 Post Yolk-sac 2

33.9 0.28 1

16.2 0.05 ICTiOBINAE sp.

Yolk-sac 351 5,949.4 49.09 1,009 16,371.4 52.85 Post Yolk-sac 6

101.7 0.84 20 324.5 1.05 CATOSTOMIDAE sp.

Yolk-sac 3

50.8 0.42 PU MPKINSEED type Yolk-sac 3

48.7 0.16 WALLEYE Post Yolk-sac 1

16.2 0.05 Sander sp.

Yolk-sac 9

146.0 0.47 Post Yolk-sac 1

16.9 0.14 LOGPERCH type Yolk-sac 31 525.4 4.34 71 1,152.0 3.72 DARTER sp.

Yolk-sac 15 254.2 2.10 45 730.1 2.36 Post Yolk-sac 2

33.9.

0.28 FRESHWATER DRUM Egg 71 1,203.4 9.93 52 843.7 2.72 UNIDENTIFIED Egg 12 203.4 1.68 23 373.2 1.20 Yolk-sac 3

50.8 0.42 7

113.6 0.37 Larvae 2

32.5 0.10 TOTAL ICHTHYOPLANKTON 715 12,119.2 100.00 1,909 30,974.2 100.00

Table 20 (cont.)

20 May Day Night Taxa Life Stage No.

Den.

%____ No.

Den.

COMMON CARP Egg 1

14.7 2.94 1

13.4 0.72 Yolk-sac 2

26.8 1.45 Post Yolk-sac 1

13.4 0.72 Semotilus type Yolk-sac 1

14.7 2.94 4

53.6 2.90 Post Yolk-sac 7

93.9 5.07 CYPRINIDAE sp.

Yolk-sac 4

58.9 11.76 10 134.1 7.25 Moxostoma sp.

Yolk-sac 1

14.7 2.94 16 214.5 11.59 Post Yolk-sac 2

26.8 1.45 ICTIOBINAE sp.

Yolk-sac 14 206.2 41.18 46 616.8 33.33 Post Yolk-sac 23 308.4 16.67 LOGPERCH type Yolk-sac 6

88.4 17.65 7

93.9 5.07 DARTER sp.

Yolk-sac 4

58.9 11.76 17 227.9 12.32 Post Yolk-sac 1

13.4 0.72 FRESHWATER DRUM Egg 1

14.7 2.94 MoronelPomoxis type Egg 2

29.5 5.88 1

13.4 0.72 TOTAL ICHTHYOPLANKTON 34 500.9 100.00 138 1,850.4 100.00 28 May Day Night Taxa Life Stage No.

Den.

No.

Den.

Dorosoma sp.

Post Yolk-sac 11 192.2 4.72 6

104.3 1.54 COMMON CARP Yolk-sac 19 332.0 8.15 95 1,650.8 24.42 Post Yolk-sac 1

17.5 0.43 BLUNTNOSE MINNOW Juvenile 2

34.8 0.51 CYPRINIDAE sp.

Egg 22 384.4 9.44 Yolk-sac 115 2,009.3 49.36 36 625.6 9.25 Moxostoma sp.

Post Yolk-sac 2

34.8 0.51 ICTIOBINAE sp.

Yolk-sac 40 698.9 17.17 184 3,197.3 47.30 Morone sp.

Yolk-sac 1

17.5 0.43 PUMPKINSEED type Yolk-sac 2

34.8 0.51 LOGPERCH type Yolk-sac 3

52.4 1.29 4

69.5 1.03 Post Yolk-sac 2

34.9 0.86 DARTER sp.

Yolk-sac 2

34.9 0.86 3

52.1 0.77 FRESHWATER DRUM Egg 17 297.0 7.30 9

156.4 2.31 ROUND GOBY Juvenile 40 695.1 10.28 MoronelPomoxis type Egg 6

104.3 1.54 TOTAL ICHTHYOPLANKTON 233 4,070.9 100.00 389 6,759.5 100.00 3 June Day Night Taxa Life Stage No.

Den.

%____ No.

Den.

Dorosoma sp.

Yolk-sac 2

33.8 0.33 Post Yolk-sac 22 371.9 3.61 25 438.0 6.14 COMMON CARP Yolk-sac 3

50.7 0.49 5

87.6 1.23 BLUNTNOSE MINNOW Post Yolk-sac 1

17.5 0.25 Pimephales type Yolk-sac 51 893.5 12.53 Semotiluis type Yolk-sac 1

17.5 0.25 CYPRINIDAE sp.

Yolk-sac 439 7,421.4 72.09 157 2,750.6 38.57 Moxostoma sp.

Post Yolk-sac 2

35.0 0.49 ICTIOBINAE sp.

Yolk-sac 1

17.5 0.25 Post Yolk-sac 1

17.5 0.25 BLUEGILL type Post Yolk-sac 3

52.6 0.74 PUMPKINSEED type Yolk-sac 2

33.8 0.33 2

35.0 0.49 Lepomis sp.

Post Yolk-sac 1

16.9 0.16 Sander sp.

Yolk-sac 1

16.9 0.16 LOGPERCH type Yolk-sac 1

17.5 0.25 DARTER sp.

Yolk-sac 3

50.7 0.49 6

105.1 1.47 Post Yolk-sac 1

17.5 0.25 FRESHWATER DRUM Egg 135 2,282:2 22.17 114 1,997.3 28.01 Yolk-sac 3

52.6 0.74 Post Yolk-sac 1

16.9 0.16 ROUND GOBY Juvenile 30 525.6 7.37 UNIDENTIFIED Yolk-sac 3

52.6 0.74 TOTALICHTHYOPLANKTON TTLCTH PANTN609 10,295.3 100.00 407 7,130.7 100.00

Tabie 20 (cont.)

11 June Day Night No.

Den.

No.

Den.

Taxa GAR sp.

Dorosoma sp.

COMMON CARP Pimephales type Semotilus type CYPRINIDAE sp.

Moxostoma sp.

ICTIOBINAE sp.

ROCK BASS PUMPKINSEED type LOGPERCH type DARTER sp.

FRESHWATER DRUM ROUND GOBY UNIDENTIFIED TOTAL ICHTHYOPLANKTON Life Stage Post Yolk-sac Post Yolk-sac Egg Yolk-sac Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Egg Juvenile Yolk-sac 1

17.5 0.23 17 297.7 3.99 22 274 4,799.0 64.32 71 5

87.6 1.17 21 9

157.6 2.11 31 2

35.0 0.47 1

44 770.6 10.33 56 11 192.7 2.58 2

35.0 0.47 4

1 1

17.5 0.23 1

3 52.5 0.70 1

5 87.6 1.17 1

1 17.5 0.23 2

5 87.6 1.17 5

44 770.6 10.33 8

1 17.5 0.23 20 1

17.5 0.23 426 7,461.2 100.00 245 371.7 1,199.4 354.8 523.7 16.9 946.0 67.6 16.9 16.9 16.9 16.9 33.8 84.5 135.1 337.9 8.98 28.98 8.57 12.65 0.41 22.86 1.63 0.41 0.41 0.41 0.41 0.82 2.04 3.27 8.16 4,138.9 100.00 Taxa Life Stage Dorosoma sp.

Yolk-sac Post Yolk-sac COMMON CARP Egg Yolk-sac Pimephales type Yolk-sac CYPRINIDAE sp.

Yolk-sac Moxostoma sp.

Post Yolk-sac ICTIOBINAE sp.

Yolk-sac GREEN SUNFISH Juvenile PUMPKINSEED type Yolk-sac Post Yolk-sac Lepomis sp.

Post Yolk-sac Sander sp.

Yolk-sac LOGPERCH type Yolk-sac DARTER sp.

Yolk-sac Post Yolk-sac FRESHWATER DRUM Egg Yolk-sac Post Yolk-sac ROUND GOBY Juvenile UNIDENTIFIED Yolk-sac TOTAL ICHTHYOPLANKTON 17 June Day Night No.

Den.

No.

Den.

15 273.4 2.79 25 455.6 4.66 28 496.6 8.24 17 309.8 3.17 22 390.2 6.47 3

54.7 0.56 111 2,022.9 20.67 123 2,181.4 36.18 324 5,904.8 60.34 103 1,826.7 30.29 4

70.9 1.18 15 273.4 2.79 9

159.6 2.65 1

17.7 0.29 3

54.7 0.56 4

70.9 1.18 2

35.5 0.59 1

18.2 0.19 1

17.7 0.29 2

35.5 0.59 7

127.6 1.30 10 177.3 2.94 2

36.4 0.37 9

159.6 2.65 12 218.7 2.23 4

70.9 1.18 1

18.2 0.19 1

17.7 0.29 5

88.7 1.47 12 212.8 3.53 1

18.2 0.19 537 9,786.6 100.00 340 6,029.8 100.00 Taxa Life Stage GIZZARD SHAD Juvenile Dorosoma sp.

Yolk-sac Post Yolk-sac COMMON CARP Egg Yolk-sac Hypophthalmichthys type Egg BLUNTNOSE MINNOW Juvenile Pimephales type Yolk-sac CYPRINIDAE sp.

Yolk-sac ICTIOBINAE sp.

Yolk-sac Post Yolk-sac Juvenile BLACKSTRIPE TOPMINNOW Yolk-sac Juvenile 24 June Day Night No.

Den.

No.

Den.

3 45.4 1.02 1

18.2 0.84 17 308.7 14.29 22 333.0 7.48 2

36.3 1.68 6

90.8 2.04 11 199.8 9.24 47 711.3 15.99 19 345.1 15.97 11 166.5 3.74 2

30.3 0.68 36 653.8 30.25 100 1,513.5 34.01 19 345.1 15.97 40 605.4 13.61 6

90.8 2.04 1

15.1 0.34 2

30.3 0.68 1

18.2 0.84 1

15.1 0.34

Table 20 (cont.)

24 June (cont.)

Day Night Taxa (cont.)

Life Stage No.

Den.

%____ No.

Den.

BROOK SILVERSIDE Yoik-sac 2

30.3 0.68 PUMPKINSEED type Yolk-sac 3

54.5 2.52 6

90.8 2.04 Post Yolk-sac 1

15.1 0.34 Lepomis sp.

Post Yolk-sac 3

45.4 1.02 LARGEMOUTH BASS Juvenile 1

15.1 0.34 LOGPERCH type Yolk-sac 4

60.5 1.36 DARTER sp.

Yolk-sac 4

72.6 3.36 5

75.7 1.70 Post Yolk-sac 1

18.2 0.84 3

45.4 1.02 Juvenile 2

30.3 0.68 FRESHWATER DRUM Egg 3

54.5 2.52 Post Yolk-sac 1

18.2 0.84 13 196.8 4.42 Juvenile 1

15.1 0.34 ROUND GOBY Juvenile 12 181.6 4.08 UNIDENTIFIED Yolk-sac 1

18.2 0.84 TOTAL ICHTHYOPLANKTON 119 2,161.2 100.00 294 4,449.7 100.00 9 July Day Night Taxa Life Stage No.

Den.

%____ No.

Den.

GAR sp.

Post Yolk-sac GIZZARD SHAD Juvenile Dorosoma sp.

Post Yolk-sac COMMON CARP Egg Yolk-sac Hypophthalmichthys type Egg Pimephales type Yolk-sac Post Yolk-sac CYPRINIDAE sp.

Yolk-sac ICTIOBINAE sp.

Yolk-sac CHANNEL CATFISH Juvenile PUMPKINSEED type Post Yolk-sac Juvenile Lepomis sp.

Post Yolk-sac LOGPERCH type Yolk-sac DARTER sp.

Yolk-sac 2

30.6 1.90 1

16.9 8.33 3

45.9 2.86 2

33.7 16.67 1

15.3 0.95 1

15.3 0.95 4

67.5 33.33 1

16.9 8.33 31 474.8 29.52 2

30.6 1.90 20 306.3 19.05 1

16.9 8.33 3

45.9 2.86 4

61.3 3.81 2

30.6 1.90 2

30.6 1.90 1

16.9 8.33 1

16.9 8.33 1

16.9 8.33 4

61.3 3.81 1

15.3 0.95 29 444.1 27.62 FRESHWATER DRUM Egg Yolk-sac Juvenile ROUND GOBY TOTAL ICHTHYOPLANKTON 12 202.4 100.00 105 1,608.1 100.00 15 July Day Night Taxa Life Stage No.

Den.

%____ No.

Den.

GIZZARD SHAD Juvenile 1

16.2 0.54 Dorosoma sp.

Post Yolk-sac 2

34.2 5.00 4

64.7 2.17 COMMON CARP Egg 13 222.0 32.50 4

64.7 2.17 Yolk-sac 5

80.8 2.72 Juvenile 1

16.2 0.54 Pimephales type Yolk-sac 6

102.5 15.00 87 1,406.6 47.28 CYPRINIDAE sp.

Yolk-sac 12 205.0 30.00 29 468.9 15.76 CATOSTOMIDAE sp.

Yolk-sac 1

17.1 2.50 CHANNEL CATFISH Juvenile 12 194.0 6.52 BANDED KILLIFISH Juvenile 1

16.2 0.54 PUMPKINSEED type Yolk-sac 10 161.7 5.43 Lepomis sp.

Yolk-sac 1

17.1 2.50 Post Yolk-sac 2

32.3 1.09 Juvenile 19 307.2 10.33 LOGPERCH type Yolk-sac 3

48.5 1.63 DARTER sp.

Post Yolk-sac 1

16.2 0.54 FRESHWATER DRUM Egg 3

51.2 7.50 2

32.3 1.09 Yolk-sac 2

34.2 5.00 ROUND GOBY Juvenile 3

48.5 1.63 TOTAL ICHTHYOPLANKTON TTLCHH PLNTN40 683.2 100.00 184 2,974.9 100.00

Table 20 (cont.)

22 July Day Night Taxa (cont.)

Life Stage No.

Den.

%____ No.

Den.

Pimephales type Yolk-sac 5

87.1 31.25 25 424.0 75.76 CYPRINIDAE sp.

Yolk-sac 1

17.4 6.25 6

101.8 18.18 FRESHWATER DRUM Yolk-sac 4

69.6 25.00 2

33.9 6.06 UNIDENTIFIED Egg 4

69.6 25.00 Yolk-sac 2

34.8 12.50 TOTAL ICHTHYOPLANKTON 16 278.6 100.00 33 559.7 100.00 29 July Day Night Taxa Life Stag1e No.

Den.

%____ No.

Den.

Dorosoma sp.

Post Yolk-sac 2

27.3 2.56 COMMON CARP Egg 5

75.3 23.81 Yolk-sac 1

13.6 1.28 Pimephales type Yolk-sac 1

15.1 4.76 47 640.5 60.26 CYPRINIDAE sp.

Yolk-sac 10 150.7 47.62 26 354.3 33.33 ICTIOBINAE sp.

Yolk-sac 1

15.1 4.76 PUMPKINSEED type Yolk-sac 1

15.1 4.76 2

27.3 2.56 FRES HWATER DRUM Yolk-sac 1

15.1 4.76 UNIDENTIFIED Egg 2

30.1 9.52 TOTAL ICHTHYOPLANKTON 21 316.4 100.00 78 1,063.0 100.00 12 August Day Night Taxa Life Stage No.

Den.

%____ No.

Den.

Dorosoma sp.

Post Yolk-sac 1

17.2 1.54 Hypophthalmichthys type Egg 1

17.0 25.00 Pimephales type Yolk-sac 28 480.5 43.08 CYPRINIDAE sp.

Yolk-sac 20 343.2 30.77 Post Yolk-sac 14 240.2 21.54 PUMPKINSEED type Yolk-sac 2

34.3 3.08 UNIDENTIFIED Egg 1

17.0 25.00 Yolk-sac 2

34.1 50.00 TOTAL ICHTHYOPLANKTON 4

68.2 100.00 65 1,115.4 100.00 26 August Taxa Life Stage Notropis sp.

Juvenile BULLHEAD MINNOW Juvenile Pimephales type Yolk-sac Pimephales sp.

Juvenile CYPRINIDAE sp.

Yolk-sac PUMPKINSEED type Post Yolk-sac TOTAL ICHTHYOPLANKTON Note: Density (Den.) is No. per million gallons.

Day No.

Den.

1 15.4 33.33 2

30.9 66.67 3

46.3 100.00 Night No.

Den.

3 54.4 37.50 2

36.3 25.00 1

18.1 12.50 1

18.1 12.50 1

18.1 12.50 8

145.1 100.00

Table 21. Depth Comparisons of the Number, Density, and Relative Abundance of lchthyoplankton Collected during All Entrainment Sampling at LaSalle County Station River Screen House, 3 April - 26 August 2014.

Surface Bottom Taxa Life Stage No.

Den.

%___ No.

Den.

GAR sp.

Post Yolk-sac GIZZARD SHAD Juvenile Dorosoma sp.

Yolk-sac Post Yolk-sac COMMON CARP Egg Yolk-sac Post Yolk-sac Juvenile Hypophthalmichthys type Egg Notropis sp.

Juvenile BLUNTNOSE MINNOW Post Yolk-sac Juvenile BULLHEAD MINNOW Juvenile Pimephales type Yolk-sac Post Yolk-sac Pimephales sp.

Juvenile Semotilus type Yolk-sac Post Yolk-sac CYPRINIDAE sp.

Egg Yolk-sac Post Yolk-sac Moxostoma sp.

Yolk-sac Post Yolk-sac ICTIOBINAE sp.

Yolk-sac Post Yolk-sac Juvenile CATOSTOMIDAE sp.

Yolk-sac CHANNEL CATFISH Juvenile BANDED KILLIFISH Juvenile BLACKSTRIPE TOPMINNOW Yolk-sac Juvenile BROOK SILVERSIDE Yolk-sac Morone sp.

Yolk-sac ROCK BASS Post Yolk-sac GREEN SUNFISH Juvenile BLUEGILL type Post Yolk-sac PUMPKINSEED type Yolk-sac Post Yolk-sac Juvenile Lepomis sp.

Yolk-sac Post Yolk-sac Juvenile LARGEMOUTH BASS Juvenile WALLEYE Post Yolk-sac Sander sp.

Yolk-sac Post Yolk-sac LOGPERCH type Yolk-sac Post Yolk-sac DARTER sp.

Yolk-sac Post Yolk-sac Juvenile FRESHWATER DRUM Egg Yolk-sac Post Yolk-sac Juvenile ROUND GOBY Juvenile MoronelPomoxis type Egg UNIDENTIFIED Egg Yolk-sac Larvae TOTAL ICHTHYOPLANKTON Note: Density (Den.) is No. per million gallons.

2 5

16 123 238 565 18 3

2 2

341 4

28 3

10 845 10 20 10 1,180 34 4

8 3

3 20 6

8 9

24 73 13 247 9

15 48 8

13 16 2

2.0 0.05 5.1 0.12 16.2 0.39 124.9 3.01 241.7 5.82 573.8 13.81 1.0 0.02 1.0 0.02 18.3 0.44 3.0 0.07 2.0 0.05 2.0 0.05 346.3 8.33 4.1 0.10 28.4 0.68 3.0 0.07 10.2 0.24 858.1 20.65 10.2 0.24 20.3 0.49 10.2 0.24 1,198.4 28.84 34.5 0.83 1.0 0.02 4.1 0.10 8.1 0.20 1.0 0.02 1.0 0.02 1.0 0.02 3.0 0.07 1.0 0.02 3.0 0.07 20.3 0.49 6.1 0.15 1.0 0.02 8.1 0.20 9.1 0.22 1.0 0.02 24.4 0.59 94.4 2.27 2.0 0.05 74.1 1.78 13.2 0.32 250.8 6.04 9.1 0.22 15.2 0.37 48.7 1.17 8.1 0.20 13.2 0.32 16.2 0.39 2.0 0.05 1

3 107 193 330 1

17 1

1 2

352 1

4 5

12 773 15 8

9 570 18 1

8 4

1 24 2

10 10 16 16 73 52 17 2

233 6

5 1

99 1

29 10 1.0 0.03 3.1 0.10 109.4 3.54 197.4 6.39 337.5 10.92 1.0 0.03 17.4 0.56 1.0 0.03 1.0 0.03 2.0 0.07 360.1 11.65 1.0 0.03 4.1 0.13 5.1 0.17 12.3 0.40 790.7 25.58 15.3 0.50 8.2 0.26 9.2 0.30 583.0 18.86 18.4 0.60 1.0 0.03 8.2 0.26 1.0 0.03 1.0 0.03 4.1 0.13 1.0 0.03 1.0 0.03 24.5 0.79 2.0 0.07 10.2 0.33 1.0 0.03 16.4 0.53 1.0 0.03 74.7 2.42 53.2 1.72 17.4 0.56 2.0 0.07 238.3 7.71 6.1 0.20 5.1 0.17 1.0 0.03 101.3 3.28 1.0 0.03 29.7 0.96 10.2 0.33 3,091.1 100.00 4,092 4,155.6 100.00 3,022

Table 22. Depth Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Each Entrainment Sampling Event at LaSalle County Station River Screen House, 3 April - 26 August 2014.

3 April Surface Bottom Taxa Life Stagle No.

Den.

%____ No.

Den.

FRESHWATER DRUM Egg 1

16.2 100.00 24 April Surface Bottom Taxa Life Stage No.

Den.

No.

Den.

Dorosoma sp.

Post Yolk-sac 3

49.6 8.57 ICTIOBINAE sp.

Yolk-sac 1

16.5 2.86 Morone sp.

Yolk-sac 2

30 7.69 3

49.6 8.57 Sander sp.

Yolk-sac 14 210.2 53.85 13 214.8 37.14 LOGPERCH type Yolk-sac 8

120.1 30.77 15 247.9 42.86 UNIDENTIFIED Yolk-sac 2

30 7.69 TOTAL ICHTHYOPLANKTON 26 390.3 100.00 35 578.3 100.00 6 May Surface Bottom Taxa Life Stage No.

Den.

No.

Den.

Dorosoma sp.

ICTIOBINAE sp.

Morone sp.

Sander sp.

LOGPERCH type UNIDENTIFIED TOTAL ICHTHYOPLANKTON Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac 1

16.6 2.94 5

67.6 9.26 2

33.1 5.88 42 567.9 77.78 27 446.9 79.41 1

13.5 1.85 2

33.1 5.88 2

27.0 3.70 2

33.1 5.88 4

54.1 7.41 54 730.1 100.00 34 562.8 100.00 13 May Surface Bottom Taxa Life Stage No.

Den.

%____ No.

Den.

Dorosoma sp.

COMMON CARP Semotilus type CYPRINIDAE sp.

Moxostoma sp.

ICTIOBINAE sp.

CATOSTOMIDAE sp.

PUMPKINSEED type WALLEYE Sander sp.

LOGPERCH type DARTER sp.

FRESHWATER DRUM UNIDENTIFIED Post Yolk-sac Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Egg Egg Yolk-sac Larvae 8

138.6 5

86.6 451 7,812.3 23 398.4 79 1,368.5 8

138.6 2

34.6 990 17,148.9 19 329.1 3

52.0 1

17.3 8

138.6 62 1,074.0 31 537.0 2

34.6 56 970.0 9

155.9 7

121.3 2

34.6 1,766 30,590.9 0.45 5

79.5 0.28 7

111.3 25.54 226 3,593.0 1.30 3

47.7 4.47 66 1,049.3 0.45 3

47.7 0.11 1

15.9 56.06 370 5,882.4 1.08 7

111.3 0.17 3

47.7 0.06 0.45 1

15.9 1

15.9 3.51 40 635.9 1.76 29 461.1 0.11 3.17 67 1,065.2 0.51 26 413.4 0.40 3

47.7 0.11 0.58 0.82 26.34 0.35 7.69 0.35 0.12 43.12 0.82 0.35 0.12 0.12 4.66 3.38 7.81 3.03 0.35 TOTALICHTHYOPLANKTON TOA IHHYPANTN100.00 858 13,640.8 100.00

Table 22 (cont.)

20 May Surface Bottom Taxa Life Stage No.

Den.

%____ No.

Den.

COMMON CARP Egg 1

14.2 0.87 1

13.9 1.75 Yolk-sac 1

14.2 0.87 1

13.9 1.75 Post Yolk-sac 1

14.2 0.87 Semotilus type Yolk-sac 5

70.9 4.35 Post Yolk-sac 2

28.4 1.74 5

69.5 8.77 CYPRINIDAE sp.

Yolk-sac 13 184.4 11.30 1

13.9 1.75 Moxostoma sp.

Yolk-sac 12 170.2 10.43 5

69.5 8.77 Post Yolk-sac 2

28.4 1.74 ICTIOBINAE sp.

Yolk-sac 37 524.7 32.17 23 319.7 40.35 Post Yolk-sac 14 198.5 12.17 9

125.1 15.79 LOGPERCH type Yolk-sac 9

127.6 7.83 4

55.6 7.02 DARTER sp.

Yolk-sac 15 212.7 13.04 6

83.4 10.53 Post Yolk-sac 1

13.9 1.75 FRESHWATER DRUM Eaa 1

13.9 1.75 Morone IPomoxis type TOTAL ICHTHYOPLANKTON Egg 3

42.5 2.61 115 1,630.8 100.00 57 792.3 100.00 28 May Surface Bottom Taxa Life Stage No.

Den.

%____ No.

Den.

Dorosoma sp.

COMMON CARP BLUNTNOSE MINNOW CYPRINIDAE sp.

Moxostoma sp.

ICTIOBINAE sp.

Morone sp.

PUMPKINSEED type LOGPERCH type DARTER sp.

FRESHWATER DRUM ROUND GOBY Morone IPomoxis type TOTAL ICHTHYOPLANKTON Post Yolk-sac Yolk-sac Post Yolk-sac Juvenile Egg Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Egg Juvenile Egg 4

71.0 1.48 13 222.5 48 851.7 17.78 66 1,129.7 1

17.1 2

34.2 10 177.4 3.70 12 205.4 68 1,206.5 25.19 83 1,420.7 2

35.5 0.74 89 1,579.1 32.96 135 2,310.7 1

17.1 1

17.7 0.37 1

17.1 3

53.2 1.11 4

68.5 2

35.5 0.74 5

88.7 1.85 12 212.9 4.44 14 239.6 21 372.6 7.78 19 325.2 5

88.7 1.85 1

17.1 3.69 18.75 0.28 0.57 3.41 23.58 38.35 0.28 0.28 1.14 3.98 5.40 0.28 270 4,790.6 100.00 352 6,025.0 100.00 3 June Surface Bottom Taxa Life Stag1e No. "

Den.

%____ No.

Den.

Dorosoma sp.

Yolk-sac 2

33.3 0.36 Post Yolk-sac 24 427.9 5.19 23 382.4 4.15 COMMON CARP Yolk-sac 4

71.3 0.87 4

66.5 0.72 BLUNTNOSE MINNOW Post Yolk-sac 1

16.6 0.18 Pimephales type Yolk-sac 10 178.3 2.16 41 681.6 7.40 Semotilus type Yolk-sac 1

16.6 0.18° CYPRINIDAE sp.

Yolk-sac 274 4,885.8 59.31 322 5,353.3 58.12 Moxostoma sp.

Post Yol k-sac 1

17.8 0.22 1

16.6 0.18 ICTIOBINAE sp.

Yolk-sac 1

17.8 0.22 Post Yolk-sac 1

16.6 0.18 BLUEGILL type Post Yolk-sac 3

53.5 0.65 PUMPKINSEED type Yolk-sac 1

17.8 0.22 3

49.9 0.54 Lepomis sp.

Post Yolk-sac 1

17.8 0.22 Sander sp.

Yolk-sac 1

17.8 0.22 LOGPERCH type Yolk-sac 1

16.6 0.18 DARTER sp.

Yolk-sac 3

53.5 0.65 6

99.8 1.08 Post Yolk-sac 1

16.6 0.18 FRESHWATER DRUM Egg 136 2,425.0 29.44 113 1,878.7 20.40 Yolk-sac 2

35.7 0.43 1

16.6 0.18 Post Yolk-sac 1

17.8 0.22 ROUND GOBY Juvenile 30 498.8 5.42 UNIDENTIFIED Yolk-sac 3

49.9 0.54 TOTAL ICHTHYOPLANKTON TTLCTYPANTN462 8,238.0 100.00 554 9,210.4 100.00

Table 22 (cont.)

11 June Surface Bottom Taxa Life Stage No.

Den.

No.

Den.

GAR sp.

Post Yolk-sac 1

17.4 0.32 Dorosoma sp.

Post Yolk-sac 18 305.2 5.04 21 366.4 6.69 COMMON CARP Egg 194 3,289.2 54.34 151 2,634.8 48.09 Yolk-sac 13 220.4 3.64 13 226.8 4.14 Pimephales type Yolk-sac 23 390.0 6.44 17 296.6 5.41 Post Yolk-sac 2

33.9 0.56 Semotilus type Post Yolk-sac 1

17.0 0.28 CYPRINIDAE sp.

Yolk-sac 43 729.1 12.04 57 994.6 18.15 Post Yolk-sac 10 169.5 2.80 1

17.4 0.32 Moxostoma sp.

Post Yolk-sac 3

50.9 0.84 3

52.3 0.96 ICTIOBINAE sp.

Post Yolk-sac 1

17.0 0.28 ROCK BASS Post Yolk-sac 1

17.0 0.28 1

17.4 0.32 PUMPKINSEED type Yolk-sac 1

17.0 0.28 3

52.3 0.98 LOGPERCH type Yolk-sac 4

67.8 1.12 2

34.9 0.64 DARTER sp.

Yolk-sac 2

33.9 0.56 1

17.4 0.32 Post Yolk-sac 3

50.9 0.84 7

122.1 2.23 FRESHWATER DRUM Egg 34 576.5 9.52 18 314.1 5.73 ROUND GOBY Juvenile 4

67.8 1.12 17 296.6 5.41 UNIDENTIFIED Yolk-sac 1

17.4 0.32 TOTAL ICHTHYOPLANKTON 357 6,052.8 100.00 314 5,479.0 100.00 17 June Surface Bottom Taxa Life Stage No.

Den.

No.

Den.

Dorosoma sp.

Yolk-sac 15 271.8 3.66 Post Yolk-sac 29 525.5 7.07 24 428.0 5.14 COMMON CARP Egg 21 380.5 5.12 18 321.0 3.85 Yolk-sac 1

18.1 0.24 2

35.7 0.43 Pimephales type Yolk-sac 58 1051.0 14.15 176 3138.8 37.69 CYPRINIDAE sp.

Yolk-sac 241 4367.1 58.78 186 3317.2 39.83 Moxostoma sp.

Post Yolk-sac 4

71.3 0.86 ICTIOBINAE sp.

Yolk-sac 12 217.4 2.93 12 214.0 2.57 GREEN SUNFISH Juvenile 1

17.8 0.21 PUMPKINSEED type Yolk-sac 2

36.2 0.49 5

89.2 1.07 Post Yolk-sac 2

36.2 0.49 Lepomis sp.

Post Yolk-sac 1

18.1 0.24 Sander sp.

Yolk-sac 1

18.1 0.24 LOGPERCH type Yolk-sac 2

36.2 0.49 DARTER sp.

Yolk-sac 11 199.3 2.68 6

107.0 1.28 Post Yolk-sac 5

90.6 1.22 6

107.0 1.28 FRESHWATER DRUM Egg 3

54.4 0.73 13 231.8 2.78 Yolk-sac 1

18.1 0.24 1

17.8 0.21 Post Yolk-sac 5

90.6 1.22 ROUND GOBY Juvenile 12 214.0 2.57 UNIDENTIFIED Yolk-sac 1

17.8 0.21 TOTAL ICHTHYOPLANKTON 410 7429.5 100.00 467 8328.6 100.00 24 June Surface Bottom Taxa Life Stage No.

Den.

No.

Den.

GIZZARD SHAD Juvenile 3

46.5 1.00 Dorosoma sp.

Yolk-sac 1

15.5 0.33 Post Yolk-sac 28 434.5 9.36 11 194.1 9.65 COMMON CARP Egg 8

124.1 2.68 Yolk-sac 41 636.2 13.71 17 299.9 14.91 Hypophthalmichthys type Egg 16 248.3 5.35 14 247.0 12.28 BLUNTNOSE MINNOW Juvenile 2

31.0 0.67 Pimephales type Yolk-sac 109 1,691.3 36.45 27 476.3 23.68 CYPRINIDAE sp.

Yolk-sac 43 667.2 "14.38 16 282.3 14.04 ICTIOBINAE sp.

Yolk-sac 6

93.1 2.01 Post Yolk-sac 1

17.6 0.88 Juvenile 1

15.5 0.33 1

17.6 0.88 BLACKSTRIPE TOPMINNOW Yolk-sac 1

17.6 0.88 Juvenile 1

15.5 0.33

Table 22 (cont.)

24 June (cont.)Surface Bottom Taxa (cont.)

Life Stage No.

Den.

%____ No.

Den.

BROOK SILVERSIDE Yolk-sac 1

15.5 0.33 1

17.6 0.88 PUMPKINSEED type Yolk-sac 7

108.6 2.34 2

35.3 1.75 Post Yolk-sac 1

15.5 0.33 Lepomis sp.

Post Yolk-sac 3

46.5 1.00 LARGEMOUTH BASS LOGPERCH type DARTER sp.

FRESHWATER DRUM ROUND GOBY UNIDENTIFIED TOTAL ICHTHYOPLANKTON Juvenile Yolk-sac Yolk-sac Post Yolk-sac Juvenile Egg Post Yolk-sac Juvenile Juvenile Yolk-sac 2

5 2

31.0 0.67 77.6 1.67 31.0 0.67 2

31.0 0.67 9

139.6 3.01 7

108.6 2.34 1

15.5 0.33 2

4 2

2 5

5 17.6 0.88 35.3 1.75 70.6 3.51 35.3 1.75 35.3 1.75 17.6 0.88 88.2 4.39 17.6 0.88 88.2 4.39 299 4,639.4 100.00 114 2,011.1 100.00 9 July Surface Bottom Taxa Life Stage No.

Den.

%____ No.

Den.

GAR sp.

GIZZARD SHAD Dorosoma sp.

COMMON CARP Post Yolk-sac Juvenile Post Yolk-sac Egg Yolk-sac Hypophthalmichthys type Egg Pimephales type Yolk-sac Post Yolk-sac CYPRINIDAE sp.

Yolk-sac ICTIOBINAE sp.

Yolk-sac CHANNEL CATFISH Juvenile PUMPKINSEED type Post Yolk-sac Juvenile Lepomis sp.

Post Yolk-sac LOGPERCH type Yolk-sac DARTER sp.

Yolk-sac FRESHWATER DRUM Egg Yolk-sac ROUND GOBY Juvenile TOTAL ICHTHYOPLANKTON 2

30.8 2.63 1

15.4 1.32 3

46.2 3.95 3

I 1

15.4 1.32 3

23 354.5 30.26 9

2 30.8 2.63 19 292.9 25.00 1

2 30.8 2.63 2

3 46.2 3.95 1

2 30.8 2.63 2

1 15.4 1.32 1

15.4 1.32 1

15.4 1.32 2

30.8 2.63 2

1 13 200.4 17.11 16 50.3 7.32 16.8 2.44 50.3 7.32 150.8 21.95 16.8 2.44 33.5 4.88 16.8 2.44 33.5 4.88 33.5 4.88 16.8 2.44 268.0 39.02 76 1,171.6 100.00 41 686.8 100.00 15 July Surface Bottom Taxa Life Stag]e No.

Den.

%____ No.

Den.

GIZZARD SHAD Dorosoma sp.

COMMON CARP Pimephales type CYPRINIDAE sp.

CATOSTOMIDAE sp.

CHANNEL CATFISH BANDED KILLIFISH PUMPKINSEED type Lepomis sp.

LOGPERCH type DARTER sp."

FRESHWATER DRUM ROUND GOBY TOTAL ICHTHYOPLANKTON Juvenile Post Yolk-sac Egg Yolk-sac Juvenile Yolk-sac Yolk-sac Yolk-sac Juvenile Juvenile Yolk-sac Yolk-sac Post Yolk-sac Juvenile Yolk-sac Post Yolk-sac Egg Yolk-sac Juvenile 1

18.1 0.81 2

36.1 1.61 4

61.5 4.00 6

108.4 4.84 11 169.1 11.00 5

90.4 4.03 1

18.1 0.81 56 1,012.0 45.16 37 568.7 37.00 25 451.8 20.16 16 245.9 16.00 1

18.1 0.81 5

90.4 4.03 7

107.6 7.00 1

18.1 0.81 4

72.3 3.23 6

92.2 6.00 1

18.1 0.81 2

36.1 1.61 9

162.6 7.26 10 153.7 10.00 3

46.1 3.00 1

18.1 0.81 1

18.1 0.81 4

61.5 4.00 2

30.7 2.00 3

54.2 2.42 124 2,240.8 100.00 100 1,537.0 100.00

Table 22 (cont.)

22 July Surface Bottom Taxa (cont.)

Life Stage No.

Den.

%____ No.

Den.

Pimephales type Yolk-sac 16 268.9 55.17 14 246.0 70.00 CYPRINIDAE sp.

Yolk-sac 5

84.0 17.24 2

35.1 10.00 FRESHWATER DRUM Yolk-sac 5

84.0 17.24 1

17.6 5.00 UNIDENTIFIED Egg 1

16.8 3.45 3

52.7 15.00 Yolk-sac 2

33.6 6.90 TOTAL ICHTHYOPLANKTON 29 487.4 100.00 20 351.5 100.00 29 July Surface Bottom Taxa Life Stage No.

Den.

%____ No.

Den.

Dorosoma sp.

Post Yolk-sac 2

29.5 3.77 COMMON CARP Egg 3

44.2 5.66 2

27.8 4.35 Yolk-sac 1

14.7 1.89 Pimephales type Yolk-sac 24 353.5 45.28 24 334.0 52.17 CYPRINIDAE sp.

Yolk-sac 16 235.7 30.19 20 278.3 43.48 ICTIOBINAE sp.

Yolk-sac 1

14.7 1.89 PUMPKINSEED type Yolk-sac 3

44.2 5.66 FRESHWATER DRUM Yolk-sac 1

14.7 1.89 UNIDENTIFIED Egg 2

29.5 3.77 TOTAL ICHTHYOPLANKTON 53 780.7 100.00 46 640.2 100.00 12 August Surface Bottom Taxa Life Stage No.

Den.

No.

Den.

Dorosoma sp.

Post Yolk-sac 1

16.9 3.85 Hypophthalmichthys type Egg 1

17.3 2.33 Pimephales type Yolk-sac 21 363.2 48.84 7

118.4 26.92 CYPRINIDAE sp.

Yolk-sac 19 328.6 44.19 1

16.9 3.85 Post Yolk-sac 14 236.7 53.85 PU MPKINSEED type Yolk-sac 1

17.3 2.33 1

16.9 3.85 UNIDENTIFIED Egg 1

17.3 2.33 Yolk-sac 2

33.8 7.69 TOTAL ICHTHYOPLANKTON 43 743.7 100.00 26 439.6 100.00 26 August Taxa Life Stage Surface No.

Den.

%___ No.

Den.

1 16.1 25.00 Notropis sp.

BULLHEAD MINNOW Pimephales type Pimephales sp.

CYPRINIDAE sp.

PUMPKINSEED type Juvenile Juvenile Yolk-sac Juvenile Yolk-sac Post Yolk-sac 3

2 1

52.1 42.86 34.7 28.57 17.4 14.29 1

2 16.1 25.00 32.1 50.00 1

17.4 14.29 TOTAL ICHTHYOPLANKTON Note: Density (Den.) is No. per million gallons.

7 121.5 100.00 4

64.2 100.00

Table 23. lchthyoplankton Taxa Entrainment Estimates for LaSalle County Station River Screen House, 30 March-30 August 2014.

Common Family Name Taxa Life Stage No.

GARS GAR sp.(l)

Post Yolk-sac 21,847 0.06 HERRINGS Dorosoma sp.

Yolk-sac 102,868 0.27 Post Yolk-sac 1,280,881 3.36 GIZZARD SHAD( 1)

Juvenile 32,604 0.09 CARPS and MINNOWS CYPRINIDAE sp.

Egg 115,919 0.30 Yolk-sac 8,694,914 22.83 Post Yolk-sac 201,993 0.53 COMMON CARP( 1)

Egg 2,258,280 5.93 Yolk-sac 4,606,691 12.10 Post Yolk-sac 9,514 0.02 Juvenile 5,023 0.01 Hypophthalmichthys type(1)

Egg 236,214 0.62 Notropis sp.Y')

Juvenile 40,367 0.11 Pimephales sp.

Juvenile 10,092 0.03 BLUNTNOSE MINNOW( 1)

Post Yolk-sac 5,203 0.01 Juvenile 23,377 0.06 BULLHEAD MINNOW(11 Juvenile 20,183 0.05 Pimnephales type( 1)

Yolk-sac 4,015,245 10.54 Post Yolk-sac 27,047 0.07 Semotilus type(1 )

Yolk-sac 156,787 0.41 Post Yolk-sac 34,918 0.09 SUCKERS CATOSTOMIDAE sp.

Yolk-sac 20,064 0.05 ICTIOBINAE sp. (2)

Yolk-sac 8,787,557 23.08 Post Yolk-sac 244,824 0.64 Juvenile 12,839 0.03 Moxostoma sp.Y')

Yolk-sac 127,322 0.33 Post Yolk-sac 97,426 0.26 NORTH AMERICAN CATFISHES CHANNEL CATFISH( 1)

Juvenile 93,570 0.25 NEW WORLD SILVERSIDES BROOK SILVERSIDE( 1)

Yolk-sac 12,839 0.03 TOPMINNOWS BLACKSTRIPE TOPMINNOWt 1 )

Yolk-sac 6,419 0.02 Juvenile 6,419 0.02 BANDED KILLIFISH(1 )

Juvenile 5,023 0.01 TEMPERATE BASSES Morone sp.(1)

Yolk-sac 67,537 0.18 SUNFISHES ROCK BASS( 1 )

Post Yolk-sac 10,402 0.03 Lepomnis sp.

Yolk-sac 5,023 0.01 Post Yolk-sac 48,267 0.13 Juvenile 95,441 0.25 GREEN SUNFISH( 1 )

Juvenile 5,436 0.01 PUMPKINSEED type' 1)

Yolk-sac 246,922 0.65 Post Yolk-sac 44,029 0.12 Juvenile 16,646 0.04 BLUEGILL type(1' Post Yolk-sac 15,610 0.04 LARGEMOUTH BASS(1 )

Juvenile 6,419 0.02 PERCHES AND DARTERS DARTER sp.(l)

Yolk-sac 637,264 1.67 Post Yolk-sac 161,981 0.43 Juvenile 12,839 0.03 LOGPERCH type(1 )

Yolk-sac 983,554 2.58 Post Yolk-sac 10,538 0.03 Sander sp.

Yolk-sac 376,707 0.99 Post Yolk-sac 5,014 0.01 WALLEYE'1 )

Post Yolk-sac 5,014 0.01 DRUMS AND CROAKERS FRESHWATER DRUM( 1)

Egg 2,501,615 6.57 Yolk-sac 80,355 0.21 Post Yolk-sac 122,255 0.32 Juvenile 6,419 0.02 GOBIES ROUND GOBY( 1)

Juvenile 874,780 2.30 UNIDENTIFIED UNIDENTIFIED Egg 215,261 0.57 Yolk-sac 154,989 0.41 Larvae 10,027 0.03 MoronelPomoxis type Egg 44,351 0.12 TOTAL ICHTHYOPLANKTON 38,078,968 100.00 TOTAL TAXA 27 (1) Counted as one taxa.

(2) Counted as two taxa.

Table 24. Comparison of Annual Impingement and Entrainment Estimates between LaSalle County Station and Other Generating Stations within the Illinois River watershed.

Typical CW Flow Estimated Station Year Mode of Cooling (mgd)'

Impingement Estimated Entrainment Will County Station2 2004-2005 Open Cycle 864 41,884 278,025,810 342004-2005 1,018 - 1,023 355,844 122,123,878 ole29Sain2005-2006 OpnCce860

- 1,007 487,786 183,196,758 Drse ula tto 5 6 7 2005-2006 1,330 - 1,400 1,016,975 88,289,628 2006-2007 1,285 - 1,402 181,274 137,264,687 LaSalle County Nuclear Station 2014-2015 Closed Cycle 86 - 88 10,673 38,078,968

'Depending on availability of data, "typical" among the various studies may represent mean or median flow in millions of gallons per day over the course of the study.

2EA 2007a.

3EA 2007b.

4EA 2007c SDresden Nuclear Station operates as indirect-open cycle during 15 June to 30 September and closed cycle the remainder of the year. Data provided are based on collections only during the 3.5 months of indirect-open cycle operation each year.

6EA 2007d.

7EA 2007e.

APPENDIX A Raw impingement data collected at LaSalle County Station River Screen House by sampling date, April 2014-March 2015

APPENDIX A - RAW IMPINGEMENT DATA LISTING SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

02-03 Apr 24.00 01-12 Apr MINIMUM= 9.0 START DATE AND TIME:

4/2/14 13:30 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN=' 9.4 END DATE AND TIME:

4/3/14 13:30 86.4 1,037 MAXIMUM= 9.8 SPECIES GIZZARD SHAD BLUEGILL BLUEGILL BLUEGILL SPOTTAIL SHINER SPOTTAIL SHINER SPOTFIN SHINER NORTHERN CLEARWATER CRAYFISH LENGTH WEIGHT 183 49 86 11 PLUS COUNT BATCH WEIGHT 114 132 76 79 38 49 27 46 S

S 1

2 SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

14-15 Apr 24.00 13-26 Apr MINIMUM= 12.4 START DATE AND TIME:

4/14/14 13:20 CW VOLUME SAMPLED (gals x 10A6):

CW EXTRAPOLATION VOLUME (gals x 10A6):

MEAN= 13.9 END DATE AND TIME:

4/15/14 13:20 86.4 1,210 MAXIMUM= 14.7 SPECIES ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY CHANNEL CATFISH BLUEGILL BLUEGILL ORANGESPOTT-ED SUNFISH GIZZARD SHAD LENGTH 78 77 67 75 72 67 86 93 90 78 63 69 81 71 82 64 83 78 77 76 82 86 87 78 77 77 84 72 80 77 140 52 47 81 99 WEIGHT PLUS COUNT BATCH WEIGHT 7

6 5

6 5

4 8

11 10 7

4 S

8 5

6 4

7 6

7 7

7 9

9 7

7 7

8 S

7 6

11 58 17 2

2 10 7

A-i

WALLEYE 355 382 SAMPLING PERIOD:

30 Apr-01 May START DATE AND TIME:

4/30/14 14:D8 END DATE AND TIME:

5/1/14 14:01 SAMPLING DURATIONS (hrs):

23.88 CW VOLUME SAMPLED (gals x 10^6):

86.0 EXTRAPOLATION PERIOD:

27 Apr-10 May CW EXTRAPOLATION VOLUME (gals x 10^6):

1,210 INTAKE TEMPERATURES (C):

MINIMUM= 14.3 MEAN= 14.7 MAXIMUM= 15.1 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT ROUND GOBY 83 8

SAMPLING PERIOD:

SAMPLING DURATIONS (hrs]:

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

12-13 May 24.03 11-24 May MINIMUM= 19.8 START DATE AND TIME:

5/12/14 13:40 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 20.8 END DATE AND TIME:

5/13/14 13:42 86.5 1,210 MAXIMUM= 21.5 SPECIES WHITE SUCKER WHITE SUCKER WHITE SUCKER WHITE SUCKER WHITE SUCKER FLATHEAD CATFISH BLUEGILL BLUEGILL BLUEGILL BLUEGILL BLUEGILL SPOTTAIL SHINER SPOTTAIL SHINER SPOTTAIL SHINER SPOTTAIL SHINER ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ROUND GOBY ORANGESPOI-FED SUNFISH O RANG ESPOI-IED SUNFISH BLUNTNOSE MINNOW CREEK CHUB SMALLMOUTH BASS LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 7

9 8

3 11 3

6 11 15 5

3 7

6 7

5 12 11 8

12 10 11 6

7 5

11 12 6

8 11 10 3

6 5

9 8

6 6

4 12 3

1 5

17 245 204 A-2

FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM ORIENTAL WEATHERFISH BLUNTNOSE MINNOW EMERALD SHINER YELLOW BU LLH EAD BLACK BULLHEAD GOLDEN REDHORSE FATHEAD MINNOW STRIPED SHINER HORNYHEAD CHUB BLACK BULLHEAD BANDED DARTER CYPRINIDAE SP.

167 153 118 147 135 137 134 145 140 179 69 62 180 45 40 14 30 23 23 24 33 25 46 5

4 83 29 1

83 3

1 1

1 48 2

6 28 89 1

1 1

1 SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

27-28 May 24.03 25 May-07 Jun MINIMUM= 22.7 START DATE AND TIME:

5/27/14 13:35 CW VOLUME SAMPLED (gals x l0^6):

CW EXTRAPOLATION VOLUME (gals x 10A6):

MEAN= 23.8 END DATE AND TIME:

5/28/14 13:37 86.5 1,210 MAXIMUM= 24.5 SPECIES ROUND GOBY EMERALD SHINER EMERALD SHINER BLUNTNOSE MINNOW STRIPED SHINER FLATHEAD CATFISH BLACK BULLHEAD LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 97 10 96 61 72 84 56 7

1 4

2 4

6 2

SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

10-11 Jun 24.00 08-21 Jun MINIMUM= 21.6 START DATE AND TIME:

6/10/14 13:45 CW VOLUME SAMPLED (gals x 10A6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 23.1 END DATE AND TIME:

6/11/14 13:45 86.4 1,210 MAXIMUM= 24.6 SPECIES AMERICAN EEL BULLHEAD MINNOW SPOTFIN SHINER ORANGESPOnED SUNFISH CHANNEL CATFISH CHANNEL CATFISH SILVERBAND SHINER LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 692 746 8

1 28 5

100 179 2

8 34 1

3 SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

24-25 Jun 24.00 22 Jun-05 Jul MINIMUM= 24.5 START DATE AND TIME:

6/24/14 15:15 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 25.2 END DATE AND TIME:

6/25/14 15:15 86.4 1,210 MAXIMUM= 26.0 SPECIES CHANNEL CATFISH CHANNEL CATFISH GREEN SUNFISH ORIENTAL WEATHERFISH LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 116 134 99 147 14 18 22 17 A-3

ROUND GOBY ROUND GOBY GRASS PICKEREL SANDER SP.

BULLHEAD MINNOW THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD LARGEMOUTH BASS THREADFIN SHAD THREADFIN SHAD SPOTFIN SHINER COMMON CARP COMMON CARP 78 55 i0i 57 65 66 63 67 58 60 59 60 53 62 46 65 63 57 46 7

2 8

1 3

2 2

3 2

2 2

3 1

2 1

3 3

7 2

1 3

3 2

SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

07-08 Jul 23.85 06-19 Jul MINIMUM= 24.6 START DATE AND TIME:

7/7/14 13:35 CW VOLUME SAMPLED (gals x 1D^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 25.7 END DATE AND TIME:

7/8/14 13:26 85.9 1,210 MAXIMUM= 26.6 SPECIES ROUND GOBY THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD BLUEGILL COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP BLACK CRAPPIE BLACK CRAPPIE BLACK CRAPPIE BLACK CRAPPIE LARGEMOUTH BASS LARGEMOUTH BASS LEPOMIS SP.

PROCAM BARUS SP.

LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 1

A-4

SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

28-29 Jul 23.92 20 Jul-02 Aug MINIMUM= 26.2 START DATE AND TIME:

7/28/14 13:45 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 26.9 END DATE AND TIME:

7/29/14 13:40 86.1 1,210 MAXIMUM= 27.3 SPECIES COMMON CARP COMMON CARP ROUND GOBY GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 399 580 285 170 85 8

64 3

47 1

56 2

53 1

51 1

52 1

51 2

49 1

56 2

55 2

63 3

52 1

51 2

53 2

74 4

57 2

50 2

50 2

55 2

55 2

49 1

51 1

49 1

53 2

53 2

47 1

57 1

50 1

SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

11-12 Aug 24.00 03-16 Aug MINIMUM= 27.2 START DATE AND TIME:

8/11/14 13:45 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 27.6 END DATE AND TIME:

8/12/14 13:45 86.4 1,210 MAXIMUM= 28.0 SPECIES THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD GREEN SUNFISH BLUNTNOSE MINNOW DOROSOMA SP.

BLUEGILL BLUEGILL PINK HEELSPLITTER LENGTH WEIGHT PLUS COUNT BATCH WEIGHT, 53 62 51 53 52 41 51 38 1

2 1

1 1

1 1

1 1

1 3

1 1

1 A-5

SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

25-26 Aug 24.10 17-3D Aug MINIMUM= 25.7 START DATE AND TIME:

8/25/14 13:30 END D CW VOLUME SAMPLED (gals x 10^6):

86.8 CW EXTRAPOLATION VOLUME (gals x 10^6):

1,210 MEAN= 26.8 MAXII*

)ATE AND TIME:

8/26/14 13:36 M1UM= 27.6 SPECIES CHANNEL CATFISH THREADFIN SHAD THREAUFIN SHAD THREADFIN SHAD THREADFIN SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD DOROSOMA SP.

DOROSOMA SP.

DOROSOMA SP.

DOROSOMA SP.

DOROSOMA SF.

DOROSOMA SP.

DOROSOMA SP.

ROUND GOBY BLUEGILL BLUEGILL GOLDEN REDHORSE NOTROPIS SF.

YELLOW BASS LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 293 212 65 2

53 1

62 3

57 2

57 2

74 4

68 3

103 9

106 10 66 2

62 3

41 1

62 2

53 1

54 1

61 2

52 2

71 2

65 4

44 1

36 1

67 4

143 49 1

1 SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

07-08 Sep 24.25 31 Aug-13 Sep MINIMUM= 25.8 START DATE AND TIME:

9/7/14 13:15 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 26.3 END DATE AND TIME:

9/8/14 13:30 87.3 1,210 MAXIMUM= 26.7 SPECIES YELLOW BASS GOLDEN SHINER CHANNEL CATFISH CHANNEL CATFISH FRESHWATER DRUM BLUEGILL BLUNTNOSE MINNOW THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD LENGTH 85 98 117 72 105 50 52 94 63 88 61 58 55 83 57 56 65 S8 54 63 57 WEIGHT 7

8 10 4

16 2

1 8

2 5

2 2

2 4

2 1

2 2

1 2

2 PLUS COUNT BATCH WEIGHT A-6

GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD DOROSOMA SP.

DOROSOMA SP.

DOROSOMA SP.

DOROSOMA SP.

PAPER PONDSHELL 90 65 66 70 48 38 46 52 6

3 3

3 1

1 1

1 6

SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

22-23 Sep 24.75 14 Sep-25 Oct MINIMUM=' 20.1 START DATE AND TIME:

9/22/14 14:0D CW VOLUME SAMPLED (gals x 1D^6):

CW EXTRAPOLATION VOLUME (gals x l0^6):

MEAN= 20.6 END DATE AND TIME:

9/23/14 14:45 89.1 1,987 MAXIMUM= 21.0 SPECIES GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD THREADFIN SHAD CHANNEL CATFISH BLUEGILL CREEK CHUB THREADFIN SHAD PAPER PONDSHELL FRAGILE PAPERSHELL LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 95 97 59 56 57 103 73 67 78 56 63 74 61 72 74 73 71 63 59 60 62 65 56 61 74 4

1 1

2 1

3 SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

24-25 Nov 24.05 26 Oct-06 Dec MINIMUM= 4.4 START DATE AND TIME: 11/24/14 13:30 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 5.6 END DATE AND TIME:

86.6 1,598 MAXIMUM= 7.3 11/25/14 13:33 SPECIES SMALLMOUTH BUFFALO WARMOUTH FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 423 95 154 94 119 113 112 101 1260 29 49 9

17 13 14 10 A-7

FRESHWATER DRU M 107 13 FRESHWATER DRUM 120 20 FRESHWATER DRUM 110 13 FRESHWATER DRUM 110 16 FRESHWATER DRUM 97 11 FRESHWATER DRUM 109 1.2 FRESHWATER DRUM 133 24 FRESHWATER DRU M 106 11 GIZZARD SHAD 122 13 GIZZARD SHAD16 LARGEMOUTH BASS 77 7

LARGEMOUTH BASS 71 6

BLUEGILL 148 65 BLUEGILL 147 66 BLUEGILL 115 32 BLUEGILL 43 1

BLUEGILL 44 2

BLUEGILL 43 2

BLUEGILL 88 12 BLUEGILL 56 4

THREADFIN SHAD 108 12 THREADFIN SHAD18 GOLDFISH 92 14 GOLDFISH 75 8

GOLDFISH 55 3

GOLDFISH 86 10 GOLDFISH 70 6

BLACK BULLHEAD 145 47 BLACK BULLHEAD 163 76 BLACK BULLHEAD 137 37 BLACK BULLHEAD 143 48 GREEN SUNFISH 67 7

GREEN SUNFISH 70 7

GREEN SUNFISH 63 6

GREEN SUNFISH 66 7

GREEN SUNFISH 50 3

GREEN SUNFISH 51 3

GREEN SUNFISH 39 1

GREEN SUNFISH 48 2

GREEN SUNFISH 55 4

GREEN SUNFISH S0 3

GREEN SUNFISH 43 2

GREEN SUNFISH 47 2

G'REEN SUNFISH 47 2

GREEN SUNFISH 46 2

BLACK CRAPPIE 89 9

BLACK CRAPPIE 76 6

BULLHEAD MINNOW 56 2

BULLHEAD MINNOW 61 3

BULLHEAD MINNOW 56 2

FRECKLED MADTOM 63 3

NORTHERN CLEARWATER CRAYFISH 40 2

PAPER PONDSHELL26 A-8

SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

15-16 Dec 24.20 07-20 Dec MINIMUM= 6.0 START DATE AND TIME:

12/15/14 13:35 END D, CW VOLUME SAMPLED (gals x 10^6):

87.1 CW EXTRAPOLATION VOLUME (gels x 10^6):

1,210 MEAN=' 6.5 MAXII*

ATE AND TIME:

12/16/14 13:47 VAUM= 6.8 SPECIES FRESHWATER DRUM FRESHWATER DRU M FRESHWATER DRUM FRESHWATER DRUM GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD LARGEMOUTH BASS BLUEGILL SPOTTAIL SHINER NORTHERN CLEARWATER CRAYFISH LENGTH WEIGHT 111 13 112 14 105 11 117 16 102 9

92 7

PLUS COUNT BATCH WEIGHT 89 118 117 100 93 104 113 118 103 77 101 39 6

14 14 9

8 8

13 14 9

6 21 2

1 6

SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

22-23 Dec 24.00 21 Dec-10 Jan MINIMUM= 4.9 START DATE AND TIME:

12/22/14 13:35 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 5.6 END DATE AND TIME:

12/23/14 13:35 86.4 1,642 MAXIMUM= 6.8 SPECIES GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 93 8

89 7

96 8

98 8

156 31 91 8

97 9

112 12 104 10 106 11 104 10 101 9

99 9

97 8

99 10 104 10 115 13 113 13 110 12 94 7

116 1S 132 19 115 14 87 5

72 3

107 10 101 8

A-9

GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD FRESHWATER DRU M FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM BLUEGILL BLUEGILL BLUEGILL DOROSOMA SP.

YELLOW BASS NORTHERN CLEARWATER CRAYFISH 89 97 102 122 98 106 120 132 117 60 53 46 84 70 6

8 10 17 10 10 16 20 15 4

2 2

7 8

48 475 4

11 SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

26-27 Jan 23.85 11-31 Jan MINIMUM= 1.6 START DATE AND TIME:

1/26/15 13:40 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 1.8 END DATE AND TIME:

1/27/15 13:31 85.9 1,728 MAXIMUM= 2.2 SPECIES LARGEMOUTH BASS GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH BLUEGILL BLUEGILL BLUEGILL SPOTFIN SHINER GREEN SUNFISH ORANG ESPO'I-IED SUNFISH BLACK REDHORSE GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD LENGTH WEIGHT 83 86 67 66 67 58 67 66 66 54 62 56 77 62 71 46 61 128 147 136 104 114 127 124 146 113 106 113 92 104 132 126 108 8

11 S

5 4

3 5

5 5

3 3

3 7

4 6

2 4

23 26 22 10 15 21 20 28 14 12 10 7

11 21 18 ii PLUS COUNT 3

BATCH WEIGHT 11 2

12 A-10

GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GREEN SUNFISH THREADFIN SHAD 102 91 107 131 96 118 103 112 99 97 105 113 116 113 116 95 46 9

7 11 20 9

14 5

12 9

8 9

12 14 12 15 9

2 1

5 SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

09-10 Feb 24.10 01-25 Feb MINIMUM= 3.3 START DATE AND TIME:

2/9/15 13:30 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 3.7 END DATE AND TIME:

2/10/15 13:36 86.8 1,814 MAXIMUM= 4.0 SPECIES BLUEGILL BLUEGILL BLUEGILL BLUEGILL FRESHWATER DRU M FRESHWATER DRUM FRESHWATER DRUM COMMON CARP SPOTTAIL SHINER BLACK CRAPPIE BLACK CRAPPIE BLACK CRAPPIE GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH LENGTH WEIGHT 155 87 131 43 110 26 161 88 104 13 124 18 122 16 159 61 PLUS COUNT BATCH WEIGHT 27 S

76 79 74 97 110 119 100 56 84 69 74 58 60 S

6 5

9 13 15 8

3 10 S

6 3

3 SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

16-17 Mar 24.03 26 Feb-21 Mar MINIMUM= 8.1 START DATE AND TIME:

3/16/15 13:30 CW VOLUME SAMPLED (gals x 10^6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 9.1 END DATE AND TIME:

86.5 1,728 MAXIMUM= 9.9 3/17/15 13:32 SPECIES BLUEGILL BLUEGILL BLUEGILL BLUEGILL BLUEGILL LENGTH 138 140 64 57 50 WEIGHT PLUS COUNT S0 S3 4

3 2

BATCH WEIGHT A-11

GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH GOLDFISH CENTRAL MUDMINNOW CENTRAL MUDMINNOW CENTRAL MUDMINNOW CENTRAL MUDMINNOW CENTRAL MUDMINNOW CENTRAL MUDMINNOW CENTRAL MUDMINNOW CENTRAL MUDMINNOW GOLDFISH CHAN NEL CATFISH GIZZARD SHAD BLACK BULLHEAD BLACK BULLHEAD GREEN SUNFISH GREEN SUNFISH EMERALD SHINER NORTHERN CLEARWATER CRAYFISH 86 93 93 73 56 53 71 83 83 71 77 73 72 73 73 128 122 134 52 49 11 12 12 5

2 2

4 7

6 4

6 4

4 5

2 16 21 36 3

2 1

6 1

3 2

21 SAMPLING PERIOD:

SAMPLING DURATIONS (hrs):

EXTRAPOLATION PERIOD:

INTAKE TEMPERATURES (C):

30-31 Mar 23.97 22-31 Mar MINIMUM= 7.2 START DATE AND TIME:

3/30/15 13:30 CW VOLUME SAMPLED (gals x 10A6):

CW EXTRAPOLATION VOLUME (gals x 10^6):

MEAN= 8.2 END DATE AND TIME:

3/31/15 13:28 86.3 864 MAXIMUM= 9.2 SPECIES CENTRAL MUDMINNOW CENTRAL MUDMINNOW FATHEAD MINNOW BROOK SILVERSIDE FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD GOLDEN SHINER SMALLMOUTH BUFFALO ORCONECTES SP.

LENGTH WEIGHT 73 6

63 4

60 3

66 2

94 B

107 10 96 5

98 7

100 B

89 4

72 3

71 B

49 3

PLUS COUNT BATCH WEIGHT A-12

APPENDIX B Number, biomass, and relative abundance of shellfish and fish collected during impingement study at LaSalle County Station River Screen House by sampling date, April 2014-March 2015

APPEHDIX B.

NUMBER, BIOMASS, AND RELATIVE ABUNDANCE OF CRAYFISH,
MUSSELS, AND FISH COLLECTED DURING IMPINGEMENT AT LASALLE COUNTY STATION RIVER SCREEN HOUSE FOR EACH SAMPLING DATE, APRIL 2014 -

MARCH 2015.

02-03 Apr 14 14-15 Apr 14 30 Apr-01 May 14 12-13 May 14 SPECIES

_ KG KG

  1. t KG

%____f%

KG_

Orconectes sp.

Northern Clearwater Crayfish 1

12.50%

0.002 1.37%

Procaisbarus sp.

Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad 1

12.50%

0.049 33.56%

1 2.13%

0.007 1.03%

Threadfin Shad Dorosoma sp.

Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub 1

1.04%

0.089 7.81%

Golden Shiner Emerald Shiner 1

1.04%

0.003 0.26%

Striped Shiner 1

1.04%

0.028 2.46%

Spottail Shiner 2

25.00%

0.010 6.85%

4 4.17%

0.025 2.19%

Silverband Shiner Spotfin Shiner 1

12.50%

0.001 0.68%

Notropis sp.

Bluntnose Minnow 30 31.25%

0.086 7.54%

Fathead Minnow 1

1.04%

0.006 0.53%

Bullhead Minnow Creek Chub 5

5.21%

0.017 1.49%

Cyprinidae sp.

1 1.04%

0.001 0.09%

White Sucker 5

5.21%

0.038 3.33%

Smallmouth Buffalo Black Redhorse Golden Redhorse 1

1.04%

0.083 7.28%

Oriental Weatherfish 1

1.04%

0.046 4.04%

Black Bullhead 2

2.08%

0.006 0.53%

Yellow Bullhead 1

1.04%

0.005 0.44%

Channel Catfish 1

2.13%

0.017 2.51%

Freckled Madtom Flathead Catfish 1

1.04%

0.003 0.26%

Brook Silverside Yellow Bass Green Sunfish W armouth Orangespotted Sunfish 1

2.13%

0.010 1.47%

2 2.08%

0.015 1.32%

Bluegill 3

37.50%

0.084 57.53%

2 4.26%

0.004 0.59%

5 5.21%

0.040 3.51%

Lepomis sp.

Smallmouth Bass 1

1.04%

0.204 17.89%

Largemouth Bass Black Crappie Banded Darter 1

1.04%

0.001 0.09%

Walleye 1

2.13%

0.382 56.34%

Sander sp.

Freshwater Drum 9

9.38%

0.257 22.54%

Round Goby 41 87.23%

0.258 38.05%

1 100.00%

0.008 100.00%

23 23.96%

0.187 16.40%

Total Organisms 8 100.00%

0.146 100.00%

47 100.00%

0.678 100.00%

1 100.00%

0.008 100.00%

96 100.00%

1.140 100.00%

B-1

APPENDIX B (continued) 27-OR Mnv 1i4 in-il.iin 14 24-25 Jun 14 01-OR Jul 14 l.............................

SPECIES Orconectes sp.

Northern Clearwater Crayfish Procamsbarus ap.

Fragile Papershell Pink Neelsplitter Paper Pondshell American Eel Gizzard Shad Threadfin Shad Dorosoma sp.

Central Nudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis sp.

Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.

White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.

Smalimouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.

Freshwater Drum Round Goby KG

% _KG

__G

  • KG__

1 7.14%

0.746 90.31%

12 46.15%

1 3.85%

2 7.69%

2 28.57%

0.011 31.43%

1 14.29%

0.004 11.43%

1 7.14%

0.003 0.36%

1 7.14%

0.005 0.61%

1 3.85%

1 14.29%

0.002 5.71%

8 57.14%

0.028 3.39%

2 7.69%

1 3.85%

1 14.29%

0.002 5.71%

2 14.29%

0.042 5.08%

2 7.69%

1 14.29%

0.006 17.14%

1 3.85%

1 7.14%

0.002 0.24%

1 3.85%

0.028 0.008 0.005 0.003 0.007 0.017

0. 032 0.022 0.001 0.001 0.009 21.05%

6.02%

3.76%

2.26%

5.26%

12.78%

24.06%

16. 54%

0.75%

0.75%

6.77%

4.00%

20.00%

12.00%

28.00%

4.00%

4.00%

8.00%

16.00%

4.00%

0.000 0.011 0.008 0.016 0.004 0.002 0.006 0.006 0.008 18.03%

13.11%

26. 23%

6.5 6%

3.28%

9.84%

9.84%

13.11%

1 14.29%

0.010 28.57%

1 2

3.85%

7.69%

Total Organisms 7

100.00%

0.035 100.00%

14 100.00%

0.826 100.00%

26 100.00%

0.133 100.00%

25 100.00%

0.061 100.00%

B-2

APPENDIX B (continued) 22-29 Jul 1~4 KG1 An1 25-26 Anna 14 07-OS Sen 14 SPECIES Orconectes sp.

Northern Clearwater Crayfish Procamsbarus sp.

Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad Threadf in Shad Dorosoma sp.

Central Mudminnow Grass Pickerel Goldfish Cormmon Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotf in Shiner Notropis sp.

Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.

White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.

Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.

Freshwater Drum Round Goby if KG if____

KG if KG

%____f

__KG_

30 2

1 90.91%

6.06%

3.03%

- 0.050 0.750 6.2 1

9.09%

0.001 7.14%

3 9.38%

0.006 5.45%

19%

7 28.00%

0.033 10.19%

4 12.50%

0.015 13.64%

5 45.45%

0.006 42.86%

4 16.00%

0.008 2.47%

14 43.75%

0.037 33.64%

1 9.09%

0.001 7.14%

7 28.00%

0.011 3.40%

4 12.50%

0.004 3.64%

1 3.13%

0.008 7.27%

1 4.00%

0.001 0.31%

1 9.09%

0.003 21.43%

1 3.13%

0.001 0.91%

92. 8 1

2 9.09%

18.18%

0.001 0.002 7.14%

14.29%

1 1

1 2

1 4.00%

4.00%

4.00%

8.00%

4.00%

0.004 0.212

0. 049 0.002 0.004 1.23%

65.43%

15.12%

0.62%

1.23%

2 1

1 1

6.25%

3.13%

3.13%

3.13%

0.014 0.007 0.002 0.016 12.73%

6.36%

i. 82%

14.55%

0.008 0.99%

Total Organisms 33 100.00%

0.808 100.00%

11 100.00%

0.014 100.00%

25 100.00%

0.324 100.00%

32 100.00%

0.110 100.00%

B-3

APPENDIX B (continued) 22-23 Sep 14 24-25 Nov 14 15-16 Dec 14 22-23 Dec 14 SPECIES 8

_KG 8

KG_

KG U%

__KG_

Orconectes sp.

Northern Clearwater Crayfish 1

1.61%

0.002 0.10%

1 5.26%

0.002 1.00%

1 1.08%

0.008 0.88%

Procamrbarus sp.

Fragile Papershell 2

6.90%

0.003 3.19%

Pink Heelsplitter Paper Pondshell 1

3.45%

0.001 1.06%

2 3.23%

0.006 0.29%

American Eel Gizzard Shad 5

17.24%

0.020 21.28%

2 3.23%

0.019 0.91%

11 57.89%

0.111 55.50%

78 83.87%

0.786 86.56%

Threadfin Shad 18 62.07%

0.060 63.83%

2 3.23%

0.020 0.96%

Dorosomsa sp.

4 4.30%

0.011 1.21%

Central Mudmsinnow Grass Pickerel Goldfish 5

8.06%

0.041 1.96%

Common Carp Nornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner 1

5.26%

0.006 3.00%

Silverband Shiner Spotfin Shiner Notropis sp.

Bluntnose Minnow Fathead Minnow Bullhead Minnow 3

4.84%

0.007 0.33%

Creek Chub 1

3.45%

0.005 5.32%

Cyprinidae sp.

White Sucker Smallmouth Buffalo 1

1.61%

1.260 60.29%

Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead 4

6.45%

0.208 9.95%

Yellow Bullhead Channel Catfish 1

3.45%

0.001 1.06%

Freckled Madtom 1

1.61%

0.003 0.14%

Flathead Catfish Brook Silverside Yellow Bass 1

1.08%

0.007 0.77%

Green Sunfish 14 22.58%

0.051 2.44%

Warmsouth 1

1.61%

0.029 1.39%

Orangespotted Sunfish Bluegill 1

3.45%

0.004 4.26%

8 12.90%

0.184 8.80%

1 5.26%

0.021 10.50%

3 3.23%

0.008 0.88%

Lepomis sp.

Smallmouth Bass Largemouth Bass 2

3.23%

0.013 0.62%

1 5.26%

0.006 3.00%

Black Crappie 2

3.23%

0.015 0.72%

Banded Darter W alleye Sander sp.

Freshwater Drum 14 22.58%

0.232 11.10%

4 21.05%

0.054 27.00%

6 6.45%

0.088 9.69%

Round Goby Total Organisms 29 100.00%

0.094 100.00%

62 100.00%

2.090 100.00%

19 100.00%

0.200 100.00%

93 100.00%

0.908 100.00%

B-4

APPENDIX B (continued) 26-27 Jan 15 09-10 Feb 15 16-17 Mar 15 30-31 Mar 15 SPECIES KG 8

KG 8

KG

_V%

_KG Orconectes sp.

Northern Clearwater Crayfish Procaimbarus ap.

Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad Threadfin Shad Dorosoma sp.

Central Nudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis sp.

Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.

White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.

Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.

Freshwater Drum Round Goby 58.93%

1.79%

19.64%

5.36%

1.79%

3.57%

1.79%

5.36%

1.79%

0.433 0.005 0.052 0.011 0.023 0.004 0.004 0.017 0.008 77.74%

0.90%

9.34%

1.97%

4.13%

0.72%

0.72%

3.05%

1.44%

3 15.38%

23.08%

3.85%

19.23%

15.38%

11.54%

0.045 0.030 0.061 0.027 0.244 0.016 9.57%

6.38%

12.98%

5.74%

51.91%

3.40%

10.00%

3.33%

26.67%

23.33%

3.33%

6.67%

3.33%

6.67%

16. 67%

0.021 0.016 0.040 0.050 0.002 0.057

0. 002 0.005 0.112 6.89%

5.25%

13.11%

16.39%

0.66%

18.69%

0.66%

1.64%

36.72%

7.69%

23.08%

15.38%

7.69%

7.69%

7.69%

7.69%

0.003 0.019 0.010 0.003 0.003 0.008 0.002 4.23%

26.76%

14.08%

4.23%

4.23%

11.27%

2.82%

3 11.54%

0.047 10.00%

23.08%

0. 023 32.39%

Total Organisms 56 100.00%

0.557 100.00%

26 100.00%

0.470 100.00%

30 I00.00%

0.305 I00.00%

Totl rgnims5610.0%

.57 0000 2 10.0%

0.7010.0%

0 0000 030 10.0%

13 100.00%

0.071 100.00%

APPENDIX C CPE by number (No. per volume) and weight (Kg. per volume) for shellfish and fish collected during impingement study at LaSalle County Station River Screen House by sampling date, April 2014-March 2015

APPENDIX C.

CPE BY NUMBER (No. per million gallons) AND WEIGHT (Kg. per million gallons) FOR CRAYFISH,

MUSSELS, AND FISH COLLECTED DURING IMPINGEMENT AT LASALLE COUNTY STATION RIVER SCREEN HOUSE FOR EACH SAMPLING DATE, APRIL 2014 -

MARCH 2015.

02-03 Apr 14

  1. /MG

_KG/MG__

14-15 Apr 14

  1. /MG__

_KG/MG___

30 Apr-01 May 14

  1. /MG

__KG/MG 12-13 May 14

  1. /MG__

_KG/MG__

27-28 May 14

  1. /MG

_KG/MG____

Oroonectes sp.

Northern Clearwater Crayfish Procambarus sp.

Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gissard Shad Threadf in Shad Dlorosoma sp.

Central Mudminnow Grass Pickerel Goldfish Conunon Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotf in Shiner Notropis sp.

Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.

White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lep omis sp.

Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.

Freshwater Drum Round Goby 0.01157407 0.01157407 0.02314815 0.01157407 0.03472222 0.00002315 0.00056713 0.00011574 0.00001157 0.00097222 0.01157407 0.01157407 0.01157407 0.02314815 0.01157407 0.47453704 0.00008102 0.00019676 0.00011574 0.00004630 0.00442130 0.00298611

0. 01163061 0.00009304 0.01155802 0.01155802 0.01155802 0.04623209 0.34674064 0.01155802 0.05779011 0.01155802 0.05779011 0.01155802 0.01155802 0.02311604 0.01155802 0.01155802 0.02311604 0.05779011 0.01155802 0.01155802 0.10402219 0.26583449 0.00102866 0.00003467 0.00032362 0.00028895 0.00099399 0.00006935 0.00019649 0.00001156 0.00043920 0.00095932 0.00053167 0.00006935 0.00005779 0.00003467 0.00017337 0.00046232 0.00235784 0.00001156 0.00297041 0.00216135 0.02311604 0.01155802 0.01155802 0.01155802 0.01155802 0.01155802 0.00012714 0.00004623 0.00002312 0.00002312 0.00006935 0.00011558 TOTAL ORGANISMS 0.09259259 0.00168981 0.54398148 0.00784722 0.01163061 0.00009304 1.10957004 0.01317614 0.08090615 0.00040453 C-I

APPENDIX C.

CPE BY NUMBER (No APPENDIX C (continued)

IMPINGEMENT AT LA:

10-11 Jun 14 24-25 Jun 14 07-08 Jul 14 28-29 Jul 14 11-12 Aug 14 SPECIES

  1. /MG

_KG/MG__

  1. 1MG

_KG/MG__

  1. /MG

_KG/MG__

  1. /MG

_KG/MG__

_#/MG__

_KG/MG____

Orconectes sp.

Northern Clearwater Crayfish Procambarus sp.

0.01164687 0.00000000 Fragile Papershell Pink Neelsplitter 0.01157407 0.00001157 Paper Pondahell American Eel 0.01157407 0.00863426 Gizzard Shad 0.05823433 0.00012812 0.34843206 0.00058072 Threadfin Shad 0.13888889 0.00032407 0.03494060 0.00009317 0.05787037 0.00006944 Dorasoma sp.

0.01157407 0.00001157 Central Mudminnow Grass Pickerel 0.01157407 0.00009259 Goldfish Commnon Carp 0.02314815 0.00005787 0.08152807 0.00018635 0.02322880 0.00871080 Nornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner 0.01157407 0.00003472 Spotfin Shiner 0.01157407 0.00005787 0.01157407 0.00003472 Notropis sp.

Bluntnose Minnow 0.01157407 0.00003472 Fathead Minnow Bullhead Minnow 0.09259259 0.00032407 0.02314815 0.00008102 Creek Chub Cyprinidae sp.

White Sucker Smsallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish 0.01157407 0.00019676 Black Bullhead Yellow Bullhead Channel Catfish 0.02314815 0.00048611 0.02314815 0.00037037 Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish 0.01157407 0.00025463 0.01157407 0.00001157 Warmouth Orangespotted Sunfish 0.01157407 0.00002315 Bluegill 0.01164687 0.00004659 0.02314815 0.00002315 Lepomis ap.

0.01164687 0.00002329 Smallmouth Bass Largemouth Bass 0.01157407 0.00001157 0.02329373 0.00006988 Black Crappie 0.04658747 0.00006988 Banded Darter W alleye Sander sp.

0.01157407 0.00001157 Freshwater Drum Round Goby 0.02314815 0.00010417 0.01164687 0.00009317 0.01161440 0.00009292 TOTAL ORGANISMS 0.16203704 0.00956019 0.30092593 0.00153935 0.29117167 0.00071046 0.38327526 0.00938444 0.12731481 0.00016204 C-2

APPENDIX C.

CPE BY NUMBER (No APPENDIX C (continued)

IMPINGEMENT AT LA*

25-26 Aug 14 07-08 Sep 14 22-23 Sep 14 24-25 Nov 14 15-16 Dec 14 SPECIES

  1. /MG

_KG/MG__

  1. 1MG

_KG/MG__

  1. /MG

_KG/MG__

  1. /MG__

__KG/MG__

  1. /MG

_KG/MG____

Orconectes sp.

Northern Clearwater Crayfish 0.01155001 0.00002310 0.01147842 0.00002296 Procambarus sp.

Fragile Papershell 0.02244669 0.00003367 Pink Heelsplitter Paper Pondshell 0.03436426 0.00006873 0.01122334 0.00001122 0.02310002 0.00006930 American Eel Gizzard Shad 0.08068234 0.00038036 0.04581901 0.00017182 0.05611672 0.00022447 0.02310002 0.00021945 0.12626263 0.00127410 Threadfin Shad 0.04810420 0.00009221 0.16036655 0.00042383 0.20202020 0.00067340 0.02310002 0.00023100 Dlorosoma sp.

0.08068234 0.00012679 0.04581901 0.00004582 Central Mudminnow Grass Pickerel Goldfish 0.05775006 0.00047355 Common Carp Hornyhead chub Golden Shiner 0.01145475 0.00009164 Emerald Shiner Striped Shiner Spottail Shiner 0.01147842 0.00006887 Silverband Shiner Spotfin Shiner Notropis sp.

0.01152605 0.00001153 Bluntnose Minnow 0.01145475 0.00001145 Fathead Minnow Bullhead Minnow 0.03465003 0.00008085 Creek Chub 0.01122334 0.00005612 Cyprinidae sp.

White Sucker Smallmouth Buffalo 0.01155001 0.01455301 Black Redhorse Golden Redhorse 0.01152605 0.00004610 Oriental Weatherfish Black Bullhead 0.04620005 0.00240240 Yellow Bullhead Channel Catfish 0.01152605 0.00244352 0.02290951 0.00018037 0.01122334 0.00001122 Freckled Madtom 0.01155001 0.00003465 Flathead Catfish Brook Silverside Yellow Bass 0.01152605 0.00056478 0.01145475 0.00008018 Green Sunfish 0.16170016 0.00058905 Warmouth 0.01155001 0.00033495 Orangespotted Sunfish Bluegill 0.02305210 0.00002305 0.01145475 0.00002291 0.01122334 0.00004489 0.09240009 0.00212520 0.01147842 0.00024105 Lepomis sp.

Smallmouth Bass Largemouth Bass 0.02310002 0.OOO1SO1S 0.01147842 0.00006887 Black Crappie 0.02310002 0.00017325 Banded Darter W alleye Sander sp.

Freshwater Drum.

0.01145475 0.00018328 0.16170016 0.00267960 0.04591368 0.00061983 Round Goby 0.01152605 0.00004610 TOTAL ORGANISMS 0.28815122 0.00373444 0.36655212 0.00126002 0.32547699 0.0010S499 0.71610072 0.02413952 0.21808999 0.00229568 C-3

APPENDIX C.

CPE BY NUMBER (No APPENDIX C (continued)

IMPINGEMENT AT LA:

22-23 Dec 14 26-27 Jan 15 09-10 Feb 15 16-17 Mar 15 30-31 Mar 15 SPECIES

  1. /MG

_KG/MG__

  1. 1MG

_KG/MG__

  • 1MG

_KG/MG__

__i/MG__

_KG/MG__

  1. /MG

_KG/MG__

Orcanectes sp.

0.01159017 0.00003477 Morthern Clearwater Crayfish 0.01157407 0.00009259 0.03467406 0.00024272 Procambanus sp.

Fragile Papershell Pink Neelsplitter Paper Pondshell American Eel Gizzard Shad 0.90277778 0.00909722 0.38434661 0.00504309 0.04610420 0.00051867 0.01155802 0.00018493 0.03477051 0.00022021 Threadfin Shad 0.01164687 0.00005823 Dorasoma sp.

0.04629630 0.00012731 Central Mudminnow 0.09246417 0.00046232 0.02318034 0.00011590 Grass Pickerel Goldfish 0.12811554 0.00060564 0.06915629 0.00034578 0.08090615 0.00057790 Common Carp 0.01152605 0.00070309 Nornyhead Chub Golden Shiner 0.01159017 0.00003477 Emerald Shiner 0.01155802 0.00002312 Striped Shiner Spottail Shiner 0.05763024 0.00031120 Silverband Shiner Spotfin Shiner 0.03494060 0.00012812 Notropis ap.

Bluntnose Minnow Fathead Minnow 0.01159017 0.00003477 Bullhead Minnow Creek Chub Cyprinidae sp.

White Sucker Smailmouth Buffalo 0.01159017 0.00009272 Black Redhorse 0.01164687 0.00026788 Golden Redhorse Oriental Weatherfish Black Bullhead 0.02311604 0.00065881 Yellow Bullhead Channel Catfish 0.01155802 0.00002312 Freckled Madtom Flathead Catfish Brook Silverside 0.01159017 0.00002318 Yellow Bass 0.01157407 0.00008102 Green Sunfish 0.02329373 0.00004659 0.02311604 0.00005779 Warmouth Orangeapotted Sunfish 0.01164687 0.00004659 Bluegill 0.03472222 0.00009259 0.03494060 0.00019800 0.04610420 0.00281236 0.05779011 0.00129450 Lepomis sp.

Smallmouth Bass Largemouth Bass 0.01164687 0.00009317 Black Crappie 0.03457815 0.00018442 Banded Darter W alleye Sander sp.

Freshwater Drum 0.06944444 0.00101852 0.03457815 0.00054172 0.03477051 0.00026657 Round Goby TOTAL ORGANISMS 1.07638889 0.01050926 0.65222455 0.00648730 0.29967727 0.00541724 0.34674064 0.00352520 0.15067223 0.00082290 C-4

APPENDIX D Raw Ichthyoplankton Entrainment Data Collected at LaSalle County Station River Screen House, April 2014-August 2014

APPENDIX D -

RAW ENTRAINMENT DATA LISTING, LASALLE COUNTY STATION RIVER SCREEN HOUSE, 2014.

SAMPLE DATE:

3 April START DATE and TINE: O3APR14:18:02 SAMPLE DURATION (minutes): 23.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE:

A VOLUME SAMPLED (gals x 10^6) :

0.013674 STUDY GRAB TEMPERATURE (F):

47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.4 FOREBAY CURRENT VELOCITY (ft/sac) 1.50 EXTRAPOLATION PERIOD: 30 March-16 April NAXEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 106) 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT NO I CHTHYOPLAMXTON 0

SAMPLE DATE:

3 April START DATE and TIME: 03APR14:16:02 SAMPLE DURATION (minutes) : 20.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6):

0.014106 STUDY GRAB TEMPERATURE (F):

47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.4 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP MATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.

0 SAMPLE DATE: 3 April START DATE and TIME: 03APR14:18:53 SAMPLE DURATION (minutes):

11.00 DIEL PERIOD: Day DEPTH:

HOT REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.014829 STUDY GRAB TEMPERATURE (F):

47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.4 FOREBAY CURRENT VELOCITY (ft/sac) 1.30 EXTRAPOLATION PERIOD:

30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x I06) 1555.2 LIFE PLUS TARA STAGE LENGTH COUNT NO ICHTHYOPLABKTON.

0 SAMPLE DATE: 3 April START DATE and TIME:

03APR14:I8:53 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH:

HOT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.014950 STUDY GRAB TEMPERATURE (F):

47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.4 FOREBAY CURRENT VELOCITY (ft/sac) 1.30 EXTRAPOLATION PERIOD:

30 March-16 April MAKEUP MATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

1555.2 LIFE PLUS TARE STAGE LENGTH COUNT NO ICHTHYOPLMNKTON.

0 SAMPLE DATE: 3 April START DATE and TIME: O3APHI4:20:51 SAMPLE DURATION (minutes) : 20.00 DIEL PERIOD: Night DEPTH: SUE REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.015076 STUDY GRAB TEMPERATURE (F):

47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sac) 1.50 EXTRAPOLATION PERIOD:

30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x I06) 1555.2 LIFE PLUS TARA STAGE LENGTH COUNT FRESHWATER DRUM Egg 1.5 SAMPLE DATE:

3 April START DATE and TIME: O3APRb4:20:51 SAMPLE DURATION (minutes): 20.00 DIEL PERIOD: Night DEPTH:

SUE REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.018947 STUDY GRAB TEMPERATURE (F):

47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sac) 1.50 EXTRAPOLATION PERIOD:

30 March-16 April MAKEUP MATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 106) 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT MO ICHTHYOPLABXTON.

0 SAMPLE DATE:

3 April,START DATE and TIME: 03APR14:21:30 SAMPL* DURATION (minutes) :

11.00 DIEL PERIOD: Night DEPTH: HOT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.013705 STUDY GRAB TEMPERATURE (F):

47.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sac) 1.30 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP MATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

1555.2 LIFE PLUS TARE STAGE LENGTH COUNT NO ICHTHYOPLAHKTON.

0 SAMPLE DATE:

3 April START DATE and TIME: O3APR14:21:30 SAMPLE DURATION (minutes):

11.00 DIEL PERIOD: Night DEPTH:

HOT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.014804 STUDY GRAB TEMPERATURE (F):

47.7 STUDY GRAB DISSOLVED OXYGEN (mng/L) : 11.2 FOREBAY CURRENT VELOCITY (ft/sac) 1.30 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

1555.2 LIFE PLUS TARE STAGE LENGTH COUNT.

NO ICHTHYOPLANETON D-1

APPENDIX D (cant.)

SAMPLE DATE: 24 April START DATE and TIME: 24APR14:17:40 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH:

SUE REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.015063 STUDY GRAB TEMPERATURE (F):

60.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 14.3 FOREBAY CURRENT VELOCITY (ft/sea):

1.60 EXTRAPOLATION PERIOD:

17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT Morone sp.

Yolk-sac 3.0 LOGPERCH type Yolk-sac 6.9 LOGPERCN type Yolk-sac 6.4 SAMPLE DATE: 24 April START DATE and TIME: 24APR14:18:10 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Day DEPTH:

SUE REPLICATE: N VOLUME SAMPLED (gals x 10A6):

0.018359 STUDY GRAB TEMPERATURE (F) :

60.6 STUDY GRAB DISSOLVED OXYGEN (msg/L): 13.6 FOREBAY CURRENT VELOCITY (ft/sea):

1.60 EXTRAPOLATION PERIOD:

17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

1468.8 LIFE PLUS TAKA STAGE LENGTH COUNT UNIDENTIFIED Yolk-sac 5.9 SAMPLE DATE: 24 April START DATE and TIME: 24APR14:18:40 SAMPLE DURATION (minutes): 22.00 DIEL PERIOD: Day DEPTH: ROT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.015395 STUDY GRAH TEMPERATURE (F):

60.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 12.9 FOREBAY CURRENT VELOCITY (ft/sac):

1.50 EXTRAPOLATION PERIOD: 17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

1468.8 LIFE PLUS TAKE STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 7.2 Dorosoma sp.

Post Yolk-sac 6.0 LOGPERCH type Yolk-sac 6.2 LOGPERCH type Yolk-sac 5.8 LOGPERCH type Yolk-sac 6.2 LOGPERCH type Yolk-sac 9.0 LOGPERCH type Yolk-sac 6.4 LOGPERCH type Yolk-sac 6.5 LOGPERCH type Yolk-sac 6.4 LOGPERCH type Yolk-sac 8.5 SAMPLE DATE: 24 April START DATE and TIME: 24APRI4:I8:40 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH:

HOT REPLICATE: B VOLUME SAMPLED (gals x 10^6):

0.016079 STUDY GRAB TEMPERATURE (F):

60.4 STUDY GRAB DISSOLVED OXYGEN (msg/L):

12.9 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD:

17 April-S May MAEEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

1468.8 LIFE PLUS TAKE STAGE LENGTH COUNT Dorosomsa sp.

Post Yolk-sac 5.7 Morone sp.

Yolk-sac 2.7 Morone sp.

Yolk-sac 3.0 Morone sp.

Yolk-sac 2.8 LOGPERCH type Yolk-sac 6.5 LOGPERCH type Yolk-sac 6.0 LOGPERCN type Yolk-sac 8.0 SAMPLE DATE: 24 April START DATE and TIME: 24APRI4:21:45 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH:

SUE REPLICATE:

A VOLUME SAMPLED (gals x I0A6):

0.017476 STUDY GRAB TEMPERATURE (F):

59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.5 FOREBAY CURRENT VELOCITY (ft/sea):

1.60 EXTRAPOLATION PERIOD: 17 April-S May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x i0A6):

1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT Morone sp.

Yolk-sac 3.1 Sander sp.

Yolk-sac 8.1 Sander sp.

Yolk-sac 8.5 Sander ap.

Yolk-sac 7.9 Sander sp.

Yolk-sac 8.2 Sander sp.

Yolk-sac 8.0 Sander sp.

Yolk-sac 9.4 Sander sp.

Yolk-sac 7.8 LOGPERCN type Yolk-sac 6.0 LOGPERCH type Yolk-sac 7.2 LOGPERCH type Yolk-sac 6.7 LOGPERCH type Yolk-sac 6.5 UNIDENTIFIED Yolk-sac 5.7 D-2

APPENDIX D (cant.)

SAMPLE DATE: 24 April START DATE and TIME: 24APR14:21:45 SAMPLE DURATION (minutes) :

11.00 DIEL PERIOD: Night DEPTH:

SUR REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.015715 STUDY GRAB TEMPERATURE (F):

59.7 STUDY GRAB DISSOLVED OXYGEN (mag/L) : 11.5 FOREBAY CURRENT VELOCITY (ft/sec)

1. 60 EXTRAPOLATION PERIOD:

17 April-S May MAKEUP MATER VDLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

1468.8 LIFE PLUS TARA STAGE LENGTH COUNT Sander ap.

Yolk-sac 8.7 Sander sp.

Yolk-sac 8.2 Sander sp.

Yolk-sac 7.9 Sander ap.

Yolk-sac 7.9 Sander sp.

Yolk-sac 8.2 Sander sp.

Yolk-sac 8.1 Sander sp.

Yolk-sac 8.0 LOGPERCH type Yolk-sac 6.4 LOGPERCH type Yolk-sac 7.3 SAMPLE DATE: 24 April START DATE and TIME: 24APR14:22:I7 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH: HOT REPLICATE:

A VOLUME SAMPLED (gals x I0^6):

0.013408 STUDY GRAB TEMPERATURE (F) :

59.7 STUDY GRAB DISSOLVED OXYGEN (mag/L) : 11.2 FOREBAY CURRENT VELOCITY (ft/sec) 1.30 EXTRAPOLATION PERIOD: 17 April-S May MAKEUP MATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

1468.8 LIFE PLUS TARA STAGE LENGTH COUNT Sander ap.

Yolk-sac 8.3 Sander ap.

Yolk-sac 7.9 Sander ap.

Yolk-sac 7.8 Sander sp.

Yolk-sac 8.4 Sander sp.

Yolk-sac 7.6 Sander ap.

Yolk-sac 7.0 LOGPERCH type Yolk-sac 7.0 SAMPLE DATE: 24 April START DATE and TIME: 24APRI4:22:I7 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD:

Might DEPTH:

HOT REPLICATE:

B VOLUME SAMPLED (gals it 10A6):

0.015636 STUDY GRAB TEMPERATURE (F):

59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sec):

1.30 EXTRAPOLATION PERIOD: 17 April-S May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals xt 10^6):

1468.8 LIFE PLUS TARA STAGE LENGTH COUNT ICTIOBINAE sp.

Yolk-sac 5.7 Sander sp.

Yolk-sac 8.0 Sander sp.

Yolk-sac 7.5 Sander sp.

Yolk-sac 8.2 Sander sp.

Yolk-sac 8.2 Sander sp.

_Yolk-sac 9.3 Sander ap.

Yolk-sac 8.0 Sander sp.

Yolk-sac 7.8 LOGPERCH type Yolk-sac 6.8 LOGPERCH type Yolk-sac 6.7 LOGPERCH type Yolk-sac 6.6 SAMPLE DATE:

6 May START DATE and TIME: O6HAY14:18:23 SAMPLE DURATION (minutes):

16.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE:

A VOLUME SAMPLED (gals it 10^6):

0.021023 STUDY GRAB TEMPERATURE (F):

60.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 13.6 FOREBAY CURRENT VELOCITY (ft/sec):

0.90 EXTRAPOLATION PERIOD:

4-10 May MAKEUP MATER VOLUME FOR EXTRAPOLATION PERIOD (gals it 10A6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 7.4 Dorosoma sp.

Poat Yolk-sac 8.3 Dorosoma sp.

Post Yolk-sac 7.4 ICTIOBINAE ap.

Yolk-sac 8.1 ICTIOBINAE sp.

Yolk-sac 7.5 Morone sp.

Yolk-sac 3.2 LOGPERCM type Yolk-sac 6.9 LOGPERCH type Yolk-sac 5.6 SAMPLE DATE:

6 May START DATE and TIME: O6MAY14:18:23 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE:

B VOLUME SAMPLED (gals it 10^6):

0.020882 STUDY GRAB TEMPERATURE (F):

60.8 STUDY GRAB DISSOLVED OXYGEN (mg/I): 13.6 FOREBAY CURRENT VELOCITY (ft/sec):

0.90 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals it 10^6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 7.5 Dorosoma ap.

Post Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 6.7 D-3

APPENDIX D (cont.)

SAMPLE DATE:

6 May START DATE and TIME:

06MAY14:18:56 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD:

Day DEPTH: ROT REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.016915 STUDY GRAB TEMPERATURE (F):

60.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 13.6 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp.

Yolk-sac 8.0 ICTIOBINAE sp.

Yolk-sac 7.2 Sander sp.

Yolk-sac 9.5 LOGPERCN type Yolk-sac 6.3 LOGPERCH type Yolk-sac 6.5 SAMPLE DATE: 6 Nay START DATE and TIME: 06MAYl4:18:56 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.014484 STUDY GRAB TEMPERATURE (F):

60.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 13.6 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD:

4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gala x 10^6):.

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 8.1 Dorosoma sp.

Post Yolk-sac 9.3 ICTIOBINAE sp.

Yolk-sac 7.7 SAMPLE DATE:

6 May START DATE and TIME:

O6MAY14:21:01.

SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH:

SUR REPLICATE:

A VOLUME SAMPLED (gals x i0A6):

0.015896 STUDY GRAB TEMPERATURE (F):

59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.2 FOREBAY CURRENT VELOCITY (ft/sec):

1.20 EXTRAPOLATION PERIOD:

4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAB sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.9 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAS sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIOBINAE sp.

Yolk-sac 8.0 ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE ap.

Yolk-sac 8.3 ICTIOBINAE sp.

Yolk-sac 7.9 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.5 UNIDENTIFIED Yolk-sac 5.5 UNIDENTIFIED Yolk-sac 5.4 SAMPLE DATE:

6 May START DATE and TIME: O6MAY14:21:01 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH:

SUN REPLICATE:

B VOLUME SAMPLED (gala x 10^6):

0.016160 STUDY GRAB TEMPERATURE (F):

59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.2 FOREBAY CURRENT VELOCITY (ft/sec):

1.20 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE

  • PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp.

Yolk-sac 7.0 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAX sp.

Yolk-sac 7.6 ICTIOHINAE sp.

Yolk-sac 7.5 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 8.0 ICTIOBINAE ap.

Yolk-sac 7.9 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOBINAE sp.

Yolk-sac 6.8 UNIDENTIFIED Yolk-sac 5.4 UNIDENTIFIED Yolk-sac 5.3 D-4

APPENDIX D (cant.)

SAMPLE DATE:

6 May START DATE and TIME:

06MAY14:21:26 DIEL PERIOD: Night DEPTH: HOT REPLICATE: A STUDY GRAB TEMPERATURE (F):

59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.2 EXTRAPOLATION PERIOD:

4-10 May MAKEUP WATER VOLUME FOR SAMPLE DURATION (msinutea): 10.00 VOLUME SAMPLED (gals x 10'6):

0.013851 FORERAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT ICTIOHIMAE ap.

Yolk-sac 7.2 ICTIOSINAE sp.

Yolk-sac 9.0 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIOBIMAX ap.

Yolk-sac 8.4 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAE ap.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIONINAE sp.

Yolk-sac 7.0 SAMPLE DATE:

6 May START DATE and TIME: O6MAY14:21:26 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: HOT REPLICATE:

B VOLUME SAMPLED (gals a 10A6):

0.015163 STUDY GRAB TEMPERATURE (F):

59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.2 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT Dorosomna sp.

Yolk-sac 8.6 ICTIOBINAE sp.

Yolk-sac 8.5 ICTIOBINAE sp.

Yolk-sac 8.6 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIOBINAE sp.

Yolk-sac 8.1 ICTIOBINAE sp.

Yolk-sac 8.3 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIOBINAE sp.

Yolk-sac 7.9 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 8.0 ICTIOBINAE sp.

Yolk-sac 8.3 ICTIOHINAE sp.

Yolk-sac 8.3 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOHINAE sp.

Yolk-sac 7.9 Sander sp.

Yolk-sac 9.3 SAMPLE DATE: 13 May START DATE and TIME: 13MAYl4:18:37 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals a 10^6):

0.015182 STUDY GRAB TEMPERATURE (F) :

68.0 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.2 FORENAY CURRENT VELOCITY (ft/sec) 1.40 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals a 10A6):

604.8 TAXA COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP Moxos toma ap.

Moxos toma sp.

Moxos toma sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAX sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICT IOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

LIFE STAGE Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Egg Egg Egg Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-'sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac LENGTH 7.0 7.1 7.1 6.8 6.8 6.8 7.2 6.8 7.1 7.2 6.8 6.4 6.8 7.4 6.8 6.6 7.2 7.0 6.8 6.4 1.8 1.8 1.8 14.2 13.6 10.8 9.1 9.3 8.7 8.8 8.5 7.2 7.6 7.2 PLUS COUNT 41 D-5

APPENDIX D (coot.)

ICTIOBINAE sp.

Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 6.9 ICTIOBINAE sp.

Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 6.9 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOBINAE sp.

Yolk-sac 6.9 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOBINAS sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIOBINAS sp.

Yolk-sac 52 ICTIOBINAE sp.

Yolk-sac 13 LOGPERCH type Yolk-sac 6.2 LOGPERCH type Yolk-sac 6.9 LOGPERCE type Yolk-sac 6.1 DARTER sp.

Post Yolk-sac 10.1 DARTER sp.

Post Yolk-sac 7.8 DARTER sp.

Yolk-sac 7.7 DARTER sp.

Yolk-sac 6.0 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg

1. 5 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 4 UNIDENTIFIED Yolk-sac 6.0 SAMPLE DATE: 13 May START DATE and TIME:

13NAY14:18:11 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE:

H VOLUME SAMPLED (gals x 10A6):

0.014277 STUDY CRAB TEMPERATURE (F):

68.0 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.2 FOREBAY CURRENT VELOCITY (ft/sec):

1.40 EXTRAPOLATION PERIOD: 11-17 Nay MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 TAXA Dorososia sp.

Dorosomsa sp.

Dorosoma sp.

Dorosomia sp.

COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP C OMMON CARP COMM4ON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMO0N CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP Semotilus type Semotilus type Semotilus type ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOHINAE sp.

ICTIOBINAE sp.

ICTIOBINAK sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICT IOBINAE sp.

ICTIOBINAK sp.

ICT IOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOHINAE sp.

ICTIOBINAE ap.

ICTIOBINAE sp.

ICTIOBINAE sp.

LIFE STAGE Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac LENGTH 8.5 5.3 5.6 5.3 6.2 6.2 6.1 7.1 6.7 7.2 6.2 6.8 7.6 7.0 6.3 6.7 6.5 5.9 6.4 6.3 6.5 6.2 7.1 6.0 9.0 9.3 9.2 6.2 7.4 8.7 6.9 7.1 7.5 6.4 7.4 6.8 7.6 7.4 7.6 7.2 7.5 7.2 7.2 7.9 6.8 7.0 6.9 PLUS COUNT 28 D-6

APPENDIX D (cant.)

ICTIORINAE sp.

Yolk-sac 6.7 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOEINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 48 ICTIOEINAE sp.

Yolk-sac 10.0 ICTIOBINAE sp.

Yolk-sac 9.8 ICTIOBINAB sp.

Yolk-sac 9.7 ICTIOBINAE ap.

Yolk-sac 8.3 ICTIORINAE ap.

Yolk-sac.

3 ICTIOBINAE sp.

Yolk-sac.

9 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 5.9 CATOSTOMIDAE sp.

Yolk-sac 3.6 CATOSTOMIDAE sp.

Yolk-sac 5.5 CATOSTOMIDAE sp.

Yolk-sac 5.4 LOSPERCE type Yolk-sac 5.6 LOGPERCR type Yolk-sac 5.9 LOGPERCH type Yolk-sac 6.2 LOGPERCH type Yolk-sac 5.2 LOGPERCH type Yolk-sac 6.2 LOGPERCH type Yolk-sac 6.8 DARTER sp.

Yolk-sac 6.0 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg

1. 3 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg
1. 5 UNIDENTIFIED Yolk-sac 5.4 UNIDENTIFIED Yolk-sac 5.3 UNIDENTIFIED Egg 1.1 UNIDENTIFIED Egg 1.2 UNIDENTIFIED Egg 1.1 SAMPLE DATE: 13 May START DATE and TIME: l3MAY14:18:55 SAMPLE DURATION (minutes) :

11.00 DIEL PERIOD:

Day DEPTH:

ROT REPLICATE:

A VOLUME SAMPLED (gals x 10^6 ):

0.014638 STUDY GRAB TEMPERATURE (F):

67.8 STUDY GRAB DISSOLVED OXYGEN (mag/L):

8.2 FORERAY CURRENT VELOCITY (ft/sac):

1.30 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAASTAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 5.8 Dorosoma sp.

Post Yolk-sac 5.7 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 5.9 COMMON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 7.1 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 7.4 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 6.6 COM£MON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 7.1 COMMON CARP Yolk-sac 7.6 COM1MON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 38 COMMON CARP Egg 1.4 COMMON CARP Egg

1. 5 Semsotilus type Yolk-sac 9.4 Semotilus type Yolk-sac 9.3 Semsotilus type Yolk-sac 9.8 CYPRINIDAE ap.

Yolk-sac 5.3 CYPRINIDAE ap.

Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 5.8 ICTIOEINAE ap.

Yolk-sac 9.1 ICTIORINAE ap.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOHINAE sp.

Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 7.4 D-7

APPENDIX D (cant.)

ICTIOBINAE sp.

Yolk-sac 8.0 ICTIOBINAE sp.

Yolk-sac 7.9 ICTIOBINAK sp.

Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 7.0 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 7.9 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAK sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOBINAS sp.

Yolk-sac 36 ICTIOBINAE sp.

Yolk-sac 1

Sander sp.

Post Yolk-sac 10.0 LOGPERCM type Yolk-sac 6.2 LOGPERCH type Yolk-sac 5.9 LOGPERCM type Yolk-sac 6.6 LOGPERCH type Yolk-sac 4.5 DARTER sp.

Yolk-sac 6.2 DARTER sp.

Yolk-sac 6.0 DARTER sp.

Yolk-sac 6.3 DARTER sp.

Yolk-sac 5.6 FRESHWATER DRUM Egg

1. 3 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.8 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 1.9 UNIDENTIFIED Egg 1.0 UNIDENTIFIED Egg 1.0 UNIDENTIFIED Egg
1. 1 UNIDENTIFIED Egg 0.9 UNIDENTIFIED Egg 0.9 SAMPLE DATE:

13 May START DATE and TIME:

13MAY14:18:55 SAMPLE DURATION (minutes) :

18.00 DIEL PERIOD: Day DEPTH:

SOT REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.014900 STUDY GRAB TEMPERATURE (F):

67.8 STUDY GRAB DISSOLVED OXYGEN (rag/L):

8.2 FOREBAY CURRENT VELOCITY (ft/see):

1.30 EXTRAPOLATION PERIOD:

11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6) :

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 5.1 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 5.9 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 7.0 COMM4ON CARP Yolk-sac 6.8 COM£MON CARP Yolk-sac 6.5 COMMION CARP Yolk-sac 5.6 COMMON CARP Yolk-sac 6.6 COMM4ON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 6.1 CYPRINIDAE ap.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 5.5 CYPRINIDAE sp.

Yolk-sac 6.1 D-8

CYPRINIDAE sp.

CYPRINIDAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBIHAE sp.

ICTIOBIHAE sp.

ICTIOBIHAE ap.

ICTIOBINAE sp.

ICTIOBINAS sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAS sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH* type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type DARTER ap.

DARTER ap.

DARTER sp.

DARTER sp.

DARTER sp.

DARTER ap.

DARTER sp.

DARTER ap.

FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM Yolk-sac Yolk-sac Post Yell Post Yell Post Yell Post Yell Post Yell Pest Yell Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yelk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg APPENDIX D (cent.)

5.9 5.7 c-sac 9.5 c-sac 9.0 c-sac 8.6 c-sac 8.8 c-sac 8.6 c-sac 9.7 7.3 7.6 7.3 7.4 7.6 7.2 7.1 7.2 7.1 7.3 7.2 7.4 7.0 7.4 7.3 7.2 7.3 7.2 7.3 7.0 8.7 9.1 7.2 9.2 5.9 6.6 5.8 6.2 5.8 6.0 5.7 5.8 6.2 6.2 5.8 5.7 6.7 6.2 6.6 6.1 6.6 5.8 8.0 7.2 7.2 6.5 6.3 6.7 8.2 8.9 1.5 1.6 1.5 1.3 1.5 1.5 1.5 1.6 1.4 1.5 1.4 1.4 1.3 1.4 1.4 1.2 1.5 1.2 1.4 1.0 1.5 1.4 1.2 1.4 1.3 1.4 1.5 D-9

APPENDIX D (cont.)

FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.6 UNIDENTIFIED Egg 1.1 UNIDENTIFIED Egg 1.2 UNIDENTIFIED Egg 1.1 UNIDENTIFIED Egg 1.1 SAMPLE DATE: 13 May START DATE and TINE: 13MAY14:21:24 SAMPLE DURATION (minutes): 13.DO DIEL PERIOD: Night DEPTH:

SUN REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.014510 STUDY GRAB TEMPERATURE (F):

67.5 STUDY GRAB DISSOLVED OXYGEN (rag/L) :

8.1 FOREHAY CURRENT VELOCITY (ft/sec) 1.40 EXTRAPOLATION PERIOD:

11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x l0^6) :

604.8 TAXA Dorosoma sp.

Dorosoma sp.

COMMO0N CARP COMMON CARP COMMON CARP COMMO0N CARP COMMON CARP COMMO0N CARP COMMO0N CARP COMMON CARP COMMON CARP COMMON CARP COM£MON CARP COMMON CARP COMMON CARP COMMO0N CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP Semotilus type Semnotilus type Semsotilus type Semotilus type Semotilus type Semotilus type Semsotilus type Semsotilus type Semotilus type Semotilus type Semotilus type Sesmotilus type Semotilus type Semotilus type Semotilus type Semotilus type Semotilus type Semotilus type Semotilus type Semotilus type CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

Moxostoma ap.

Moxos toma sp.

Moxostoma sp.

Moxostoma sp.

ICTIOHINAE sp.

ICTIOBINAE sp.

ICTIOBINAE ap.

ICTIONINAE sp.

ICTIOBINAS sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOHINAE sp.

LIFE STAGE Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac LENGTH 10.7 5.2 6.9 6.2 6.5 6.0 6.4 7.6 6.0 6.7 6.7 6.3 7.2 6.4 6.9 6.5 6.8 6.4 7.7 6.2 6.4 6.7 7.0 9.7 9.2 9.2 9.0 9.4 9.6 8.7 9.7 8.8 8.7 7.5 6.5 6.6 6.7 6.6 6.4 8.7 8.2 7.9 8.6 8.5 5.7 5.2 5.8 5.7 5.9 6.0 7.2 6.2 6.2 5.1 5.1 5.1 5.7 14.2 12.2 13.1 10.7 8.9 9.1 9.2 9.1 9.1 7.1 7.7 7.2 PLUS COUNT 101 D-10

APPENDIX D (cant.)

ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBIMAE sp.

Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 6.9 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE ap.

Yolk-sac 8.3 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 8.1 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAS sp.

Yolk-sac 7.5 ICTIOHINAE ap.

Yolk-sac 191 ICTIOBINAE sp.

Yolk-sac.

5 Sander sp.

Yolk-sac 6.9 Sander sp.

Yolk-sac 6.7 LOGPERCH type Yolk-sac 6.0 LOGPERCH type Yolk-sac 6.3 LOGPERCH type Yolk-sac 6.0 LOGPERCH type Yolk-sac 6.1 LOGPERCH type Yolk-sac 6.1 LOGPERCH type Yolk-sac 6.4 LOGPERCH type Yolk-sac 6.6 LOGPERCE type Yolk-sac 6.5 DARTER sp.

Yolk-sac 7.0 DARTER sp.

Yolk-sac 6.6 DARTER ap.

Yolk-sac 9.2 DARTER sp.

Yolk-sac 9.2 DARTER sp.

Yolk-sac 9.2 DARTER ap.

Yolk-sac 5.9 FRESHWATER DRUM Egg

1. 6 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg
1. 7 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 8 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg 1.5 UNIDENTIFIED Larvae 2.6 UNIDENTIFIED Egg
1. 1 UNIDENTIFIED Egg
1. 2 UNIDENTIFIED Egg 1.2 UNIDENTIFIED Egg 1.4 UNIDENTIFIED Egg
1. 1 SAMPLE DATE:

13 May START DATE and TIME: 13HAY14:21:04 SAMPLE DURATION (minutes) : 22.00 DIEL PERIOD: Might DEPTH:

SUR REPLICATE: B VOLUME SAMPLED (gals x 10A6):

0.013761 STUDY GRAB TEMPERATURE (F):

67.5 STUDY GRAB DISSOLVED OXYGEN (mag/L):

8.1 FOREBAY CURRENT VELOCITY (ft/sec):

1.40 EXTRAPOLATION PERIOD: 11-17 Hay MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 5.1 Dorosoma sp.

Post Yolk-sac 8.8 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 7.1 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 7.4 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 6.1 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 6.4 COMMON CARP Yolk-sac 7.5 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 7.2 COM£MON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 6.3 COMMO0N CARP Yolk-sac 51 D-II

APPENDIX D (cant.)

COMM4ON CARP COMMO0N CARP COMM4ON CARP COMMON CARP CYPRINIDAS sp.

CYPRINIDAE ap.

CYPRINIDAS sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAS sp.

CYPRINIDAE sp.

CYPRINIDRE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

Noxostoma sp.

Noxostoma sp.

Noxostoma sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAX sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAS sp.

ICTIOBINRE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAS sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE ap.

ICTIOBINAE ap.

ICTIOBINAE sp.

WALLEYE Sander sp.

Sander sp.

Sander sp.

Sander sp.

Sander ap.

Sander sp.

LOGPERCH type LOOPERCH type LOOPERCN type LOGPERCN type LOOPERCH type LOGPERCN type LOGPERCN type LOGPERCH type LOGPERCN type LOOPERCN type LOGPERCN type LOGPERCH type LOGPERCN type LOGPERCN type LOGPERCN type LOGPERCN type LOGPERCN type LOGPERCN type LOGPERCN type Yolk-sac Yolk-sac Egg Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac 1.6 1.7 7.0 6.7 7.8 8.6 7.7 8.2 8.7 8.6 7.8 8.1 7.6 6.2 6.2 6.8 5.2 5.5 5.3 5.2 5.2 5.3 5.2 5.3 5.8 5.3 5.4 11.9 14.4 14.3 9.7 8.8 8.7 8.9 9.5 10.0 8.6 8.1 9.7 9.6 8.7 9.1 9.2 9.3 8.7 8.9 8.2 9.1 8.7 9.0 8.8 8.7 8.4 13.6 15.11 7.2 10.2 9.9 10.3 9.5 9.1 5.8 5.4 5.6 6.1 6.2 6.2 6.7 6.1 5.9 6.3 6.2 6.2 6.0 6.1 6.3 6.1 5.7 6.2 6.4 14 136 35 4

146 446 2

D-12

APPENDIX D (cant.)

LOGPERCH type Yolk-sac 5.7 LOGPERCH type Yolk-sac 14 LOGPERCH type Yolk-sac.

2 LOGPERCH type Yolk-sac.

9 DARTER sp.

Yolk-sac 7.2 DARTER sp.

Yolk-sac 7.2 DARTER sp.

Yolk-sac 7.0 DARTER sp.

Yolk-sac 6.1 DARTER sp.

Yolk-sac 6.6 DARTER sp.

Yolk-sac 9.1 DARTER sp.

Yolk-sac 6.5 DARTER sp.

Yolk-sac 6.2 DARTER sp.

Yolk-sac 6.1 DARTER sp.

Yolk-sac 6.2 DARTER ap.

Yolk-sac 6.6 DARTER sp.

Yolk-sac 7.0 DARTER sp.

Yolk-sac 7.1 DARTER sp.

Yolk-sac 8.1 DARTER sp.

Yolk-sac 7.6 DARTER sp.

Yolk-sac 7.4 DARTER sp.

Yolk-sac 7.5 DARTER ap.

Yolk-sac 6.1 DARTER sp.

Yolk-sac 7.0 DARTER sp.

Yolk-sac 7.1 DARTER sp.

Yolk-sac 5.9 DARTER sp.

Yolk-sac 6.1 FRESHWATER DRUM Egg

1. 8 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 7 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.8 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.6 UNIDENTIFIED Larvae.

UNIDNTIFED Ylk-sc 7.

UNIDENTIFIED Yolk-sac 7.1 3

UNIDENTIFIED Egg 1.1 SAMPLE DATE: 13 May START DATE and TINE: 13MAY14:21:47 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH:

HOT REPLICATE: A VOLUME SAMPLED (gals x 10^6):

0.016856 STUDY GRAB TEMPERATURE (F) :

67.3 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

8.1 FOREBAY CURRENT VELOCITY (ft/sec) 1.50 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 7.1.

COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 6.1 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 108 COMMON CARP Egg 1.5 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE ap.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 5.7 CYPRINIDAE ap.

Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRIMIDAE sp.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 5.7 CYPRINIDAE ap.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 6.3 D-13

APPENDIX D (cant.)

CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 6.2 Moxostolsa sp.

Post Yolk-sac 14.7 Moxostorta sp.

Yolk-sac 13.3 ICTIOSIl4AE sp.

Yolk-sac 7.5 ICTIORII4AE sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOBIWAE sp.

Yolk-sac 6.9 ICTIOBIWAE sp.

Yolk-sac 7.2 ICTIORINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOSINAE sp.

Yolk-sac 7.4 ICTIOBIIJAE sp.

Yolk-sac 7.0 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIORINRE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOBIWAX sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.0 ICTIOEINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 7.9 ICTIOBINAE sp.

Yolk-sac 8.6 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 154 LOGPERCU type Yolk-sac 6.5 LOGPERCIH type Yolk-sac 6.2 LOGPERCfl type Yolk-sac 6.0 LOGPERCU type Yolk-sac 6.1 LOGPEECH type Yolk-sac 5.5 DARTER sp.

Yolk-sac 6.1 DARTER ap.

Yolk-sac 6.3 DARTER sp.

Yolk-sac 9.9 DARTER sp.

Yolk-sac 7.9 DARTER ap.

Yolk-sac 8.2 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.7 UNIDENTIFIED Egg 1.7 UNIDENTIFIED Egg 1.6 UNIDENTIFIED Egg

1. 6 UNIDENTIFIED Egg 1.5 UNIDENTIFIED Egg
1. 6 UNIDENTIFIED Egg 1.5 UNIDENTIFIED Egg 1.4 UNIDENTIFIED Egg 1.3 UNIDENTIFIED Egg
1. 6 UNIDENTIFIED Egg
1. 6 UNIDENTIFIED Egg
1. 6 UNIDENTIFIED Egg
1. 4 UNIDENTIFIED Egg
1. 5 SAMPLE DATE: 13 May START DATE and TIME: 13MAY14:21:42 SAMPLE DURATION (minutes): 18.00 DIEL PERIOD: Night DEPTH: ROT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.016505 STUDY GRAB TEMPERATURE (F):

67.3 STUDY GRAB DISSOLVED OXYGEN (mig/L):

8.1 FOREHAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD:

11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 6.1 Dorosoma sp.

Post Yolk-sac 11.0 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.1 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 6.4 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.4 COMMON CARP Yolk-sac 5.7 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.2 COMMON CARP Egg 1.7 COMMON CARP Egg 1.6 COMMON CARP Egg 1.5 D-14

APPENDIX D (cant.)

COMMON CARP CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYpRINIDAE sp.

CYPRINIDAE op.

CYPRINIDAS ap.

CYPRINIDAE op.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE op.

CYPRINIDAE sp.

CYPRINIDAE op.

CYPRINIDAE op.

CYPRINIDAE op.

CYPRINIDAE op.

CYPRINIDAE op.

CYPRINIDAE sp.

CYPRINIDAE op.

Moxostoma sp.

Noxos tomia sp.

ICTIOBINAE sp.

ICT IOHINAE sp.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAB op.

ICT IOBINAE sp.

ICTIOBINAE op.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

ICTIOBINAE op.

PUMPEINSEED type PUMPKINSEED type PUMPKINSEED type Sander ap.

LOGPERCH type LOGPERCM type LOGPERCH type LOGPERCM type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCH type LOGPERCN type LOGPERCH type LOGPERCH type LOGPERCE type DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM UNIDENTIFIED Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Yolk-sac 1.6 5.7 5.9 5.7 5.1 5.4 6.2 5.8 5.3 5.4 6.1 5.3 6.2 5.5 5.2 5.2 5.7 5.2 5.6 5.7 6.2 13.3 12.9 13.7 7.2 7.2 7.2 6.9 7.4 7.2 7.3 7.5 7.2 7.2 7.2 7.1 7.0 6.9 7.0 7.2 6.8 7.3 7.2 7.1 4.3 6.3 4.7 9.1 6.7 6.0 6.0 6.2 5.8 6.1 6.8 6.4 6.6 6.5 6.1 6.2 6.4 6.2 6.0 5.9 5.0 5.1 5.7 10.2 6.0 6.2 5.2 6.0 6.1 1.3 1.4 1.4 1.4 1.6 1.4 1.5 1.5 1.4 1.5 1.5 1.4 5.8 D-15

APPENDIX D (cant.)

UNIDENTIFIED Yolk-sac 5.5 UNIDENTIFIED Yolk-sac 5.5 UNIDENTIFIED Egg 1.1 UNIDENTIFIED Egg

1. 0 UNIDENTIFIED Egg 1.1 UNIDENTIFIED Egg 1.0 SAMPLE DATE: 20 Nay START DATE and TINE: 2OMAY14:17:18 SAMPLE DURATION (minutes):

17.00 flIEL PERIOD:

Day DEPTH:

RUE REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.016534 STUDY GRAB TEMPERATURE (F):

62.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.4 FOREBAY CURRENT VELOCITY (ft/sec):

0.96 EXTRAPOLATION PERIOD: 18-24 May MAEEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Semotilus type Yolk-sac 7.7 CYPRINIDAE sp.

Yolk-sac 7.1 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 6.5 Moxostoma sp.

Yolk-sac 13.5 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAE sp.

Yolk-sac 7.8 ICTIOBINAE sp.

Yolk-sac 8.8 ICTIOBINAB sp.

Yolk-sac 8.7 ICTIOBINAE ap.

Yolk-sac 8.2 LOGPERCH type Yolk-sac 6.1 LOGPERCH type Yolk-sac 6.0 LOGPERCH type Yolk-sac 6.1 DARTER sp.

Yolk-sac 6.4 DARTER sp.

Yolk-sac 9.4 DARTER sp.

Yolk-sac 8.0 Morone/Pomoxis type Egg 0.8 Morone/Pomoxis type Egg 0.8 SAMPLE DATE: 20 May START DATE and TIME: 2OMAY14:17:18 SAMPLE DURATION (minutes): 17.00 DIEL PERIOD: Day DEPTH: SUN REPLICATE: B VOLUME SAMPLED (gals E i0A6):

0.016931 STUDY GRAB TEMPERATURE (F):

62.6 STUDY GRAB DISSOLVED OXYGEN (mgfL): 10.4 FORERAY CURRENT VELOCITY (ft/sec):

0.96 EXTRAPOLATION PERIOD: 18-24 Nay MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals E i0A6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT COMMON CARP Egg 1.7 CYPRINIDAE sp.

Yolk-sac 5.8 ICTIOBINAE sp.

Yolk-sac 7.1 SAMPLE DATE:

20 May START DATE and TIME: 2OMAY14:17:58 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD:

Day DEPTH:

NOT REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.015820 STUDY GRAB TEMPERATURE (F):

62.4 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.8 FOREBAY CURRENT VELOCITY (ft/sec):

1.34 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals E 10A6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE sp.

Yolk-sac 9.0 ICTIOBINAE sp.

Yolk-sac 9.1 ICTIOBINAE sp.

Yolk-sac 8.7 LOGPERCH type Yolk-sac 6.2 LOGPERCH type Yolk-sac 5.9 LOGPERCH type Yolk-sac 6.4 SAMPLE DATE: 20 Nay START DATE and TIME: 2OMAY14:17:&8 SAMPLE DURATION (minutes): 23.00 DIEL PERIOD: Day DEPTH: HOT REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.018595 STUDY GRAB TENPERATURE (F):

62.4 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.8 FOREBAY CURRENT VELOCITY (ft/sec):

1.34 EXTRAPOLATION PERIOD: 18-24 Nay MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals E I0A6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT ICTIOBINAE sp.

Yolk-sac 7.0 ICTIOBINAE sp.

Yolk-sac 8.3 DARTER sp.

Yolk-sac 7.8 FRESHWATER DRUM Egg 1.8 SAMPLE DATE: 20 Nay START DATE and TIME: 2OMAY14:21:11 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE:

A VOLUME SAMPLED (gals E 10A6):

0.016802 STUDY GRAB TEMPERATURE (F):

62.1 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.5 FOREBAY CURRENT VELOCITY (ft/sec):

1.30 EXTRAPOLATION PERIOD: 18-24 Nay MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Semotilus type Yolk-sac 10.0 Semotilus type Yolk-sac 9.2 D-16

APPENDIX D (cant.)

Semotilus type Yolk-sac 8.8 Semotilus type Yolk-sac 9.7 CYPRINIDAE sp.

Yolk-sac 5.8 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 7.0 CYPRINIDAS sp.

Yolk-sac 7.5 CYPRINIDRE ap.

Yolk-sac 7.4 Moxostomsa sp.

Yolk-sac 13.1 Moxostoma sp.

Yolk-sac 13.4 Moxostoma sp.

Yolk-sac 13.3 Noxostomsa sp.

Yolk-sac 13.9 Moxostoma sp.

Yolk-sac 13.9 Moxostoma ap.

Post Yolk-sac 14.8 Moxostoma sp.

Post Yolk-sac 14.8 Moxostoma sp.

Yolk-sac 14.1 Moxostoma sp.

Yolk-sac 14.2 Moxostoma sp.

Yolk-sac 14.1 Moxostoma sp.

Yolk-sac 13.8 Moxostoma sp.

Yolk-sac 13.4 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 8.3 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Post Yolk-sac 10.1 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAE sp.

Yolk-sac 8.1 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAE sp.

Yolk-sac 9.0 ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE sp.

Yolk-sac 9.4 ICTIOBINAE sp.

Yolk-sac 8.6 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 8.9 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Post Yolk-sac 10.6 ICTIOBINAS sp.

Post Yolk-sac 9.9 ICTIOBINAE sp.

Post Yolk-sac 9.4 ICTIOBINAE sp.

Post Yolk-sac 10.6 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAE sp.

Yolk-sac 8.7 ICTIOBINAE sp.

Yolk-sac 8.4 ICTIOBINAE sp.

Yolk-sac 8.3 ICTIOBINAE sp.

Yolk-sac.

2 ICTIOBINAE sp.

Post Yolk-sac 5

LOGPERCN type Yolk-sac 6.2 LOGPERCN type Yolk-sac 6.3 LOGPERCN type Yolk-sac 7.0 LOGPERCN type Yolk-sac 6.3 LOGPERCN type Yolk-sac 7.0 DARTER sp.

Yolk-sac 9.4 DARTER sp.

Yolk-sac 10.2 DARTER sp.

Yolk-sac 10.2 DARTER sp.

Yolk-sac 6.7 DARTER sp.

Yolk-sac 7.2 DARTER sp.

Yolk-sac 9.4 DARTER sp.

Yolk-sac 8.9 DARTER sp.

Yolk-sac 7.0 DARTER sp.

Yolk-sac 7.7 DARTER sp.

Yolk-sac 7.8 DARTER sp.

Yolk-sac 7.8 DARTER sp.

Yolk-sac 8.2 Morone/Pomoxis type Egg 0.7 SAMPLE DATE: 20 May START DATE and TIME: 2OMAY14:21:11 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Night DEPTN:

SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6):

0.020249 STUDY GRAB TEMPERATURE (F) :

62.1 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

9.5 FOREBAY CURRENT VELOCITY (ft/sec) 1.30 EXTRAPOLATION PERIOD:

18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAASTAGE LENGTH COUNT COMMON CARP Yolk-sac 6.7 COMMON CARP Post Yolk-sac 13.8 Semotilus type Post Yolk-sac 12.7 Semotilus type Post Yolk-sac 10.1 CYPRINIDAE sp.

Yolk-sac 7;6 CYPRINIDAE sp.

Yolk-sac 7.3 CYPRINIDAE sp.

Yolk-sac 6.8 Moxostoma sp.

Yolk-sac 13.4 ICTIOBINAE sp.

Yolk-sac 10.0 ICTIOBINAE sp.

Yolk-sac 10.0 ICTIOBINAE sp.

Yolk-sac 10.1 D-17

APPENDIX D (cont.)

ICTIOBINAE sp.

Post Yolk-sac 10.5 ICTIOBIMAE sp.

Yolk-sac 7.5 ICTIOBINAE sp.

Post Yolk-sac 10.4 ICTIOBINAE sp.

Post Yolk-sac 10.4 ICTIOBIHAE sp.

Post Yolk-sac 10.3 ICTIOBINAE sp.

Yolk-sac 2

LOGPERCH type Yolk-sac 6.8 SAMPLE DATE: 20 May START DATE and TIME: 20MAY14:21:42 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Night DEPTH: NOT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.021624 STUDY GRAB TEMPERATURE (F):

61.9 STUDY GRAB DISSOLVED OXYGEN (mag/L):

10.0 FOREBAY CURRENT VELOCITY (ft/sec) 1.40 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 106) 604.8 LIFE PLUS TAXA STAGE LENGTH COURT COMMON CARP Yolk-sac 7.1 Semotilus type Post Yolk-sac 9.8 Semotilus type Post Yolk-sac 9.0 Semotilus type Post Yolk-sac 7.9 Semotilus type Post Yolk-sac 7.9 Semotilus type Post Yolk-sac 10.9 CYPRINIDAE sp.

Yolk-sac 6.5 Noxostoma ap.

Yolk-sac 14.1 Moxostoma sp.

Yolk-sac 14.2 Moxostoma sp.

Yolk-sec 13.8 ICTIOBINAE sp.

Yolk-sac 6.2 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Post Yolk-sac 9.6 ICTIOBINAE sp.

Post Yolk-sac 10.0 ICTIOBINAE sp.

Yolk-sac 8.7 ICTIOBINAE sp.

Yolk-sac 7.9 ICTIOBINAE sp.

Yolk-sac 8.5 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOBINAN sp.

Post Yolk-sac 10.1 ICTIOBINAE sp.

Post Yolk-sac 10.4 ICTIOBINAE sp.

Yolk-sac 8.7 ICTIOBINAE sp.

Post Yolk-sac 9.5 ICTIOBINAE sp.

Post Yolk-sac 10.2 ICTIOHINRE sp.

Yolk-sac 8.0 ICTIOBINAE ap.

Yolk-sac 8.7 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOBINAX sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 8.1 LOGPERCH type Yolk-sac 7.0 DARTER sp.

Yolk-sac 7.2 DARTER sp.

Yolk-sac 7.8 DARTER sp.

Yolk-sac 9.1 DARTER sp.

Yolk-sac 10.2 DARTER sp.

Yolk-sac 8.7 SAMPLE DATE: 20 May START DATE and TIME: 2ONAY14:21:42 SAMPLE DURATION (minutes): 23.00 DIEL PERIOD: Night DEPTH:

HOT REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.015906 STUDY GRAB TEMPERATURE (F):

61.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.0 FOREBAY CURRENT VELOCITY (ft/sac):

1.40 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT COMMON CARP Egg 1.9 Moxostoma sp.

Yolk-sac 12.2 Moxostoma sp.

Yolk-sac 12.7 ICTIOBINAE sp.

Yolk-sac 8.2 ICTIOBINAE sp.

Yolk-sac 8.0 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIONINAE ap.

Post Yolk-sac 9.9 ICTIOBINAE ap.

Post Yolk-sac 11.0 ICTIOBINAE ap.

Post Yolk-sac 10.2 DARTER sp.

Post Yolk-sac 10.2 SAMPLE DATE: 28 Hay START DATE and TIME: 28MAY14:18:55 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.015019 STUDY GRAB TEMPERATURE (F):

75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.5 FOREBAY CURRENT VELOCITY (ft/sec):

1.70 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 6.2 Dorosomsasp.

Post Yolk-sac 5.1 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 5.7 COMMON CARP Yolk-sac 6.8 CYPRINIDAE sp.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 1.9 D-18

APPENDIX D (cant.)

CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 2.0 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAS sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 1.9 CYPRINIDAE sp.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 2.5 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAS sp.

Yolk-sac 1.7 CYPRIHIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 5

CYPRINIDAE sp.

Egg 2.0 CYPRINIDAE sp.

Egg 1.8 CYPRINIDAB sp.

Egg 1.8 ICTIORINAE sp.

Yolk-sac 7.0 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOHINAE sp.

Yolk-sac 7.8 ICTIOBINAE sp.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.4 LOGPERCE type Yolk-sac 5.8 LOGPERCH type Post Yolk-sac 9.8 LOGPERCH type Post Yolk-sac 10.2 DARTER sp.

Yolk-sac 7.1 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 SAMPLE DATE: 28 May START DATE and TIME:

28NAY14:18:55 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE:

H VOLUME SAMPLED (gals x 10A6):

0.014093 STUDY GRAB TEMPERATURE (F):

75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.5 FOREBAY CURRENT VELOCITY (ft/sec):

1.70 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals a 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTH COURT COMMON CARP Yolk-sac 7.7 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.2 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 2.0 CYPRINIDAE sp.

Egg 1.i CYPRINIDAE sp.

Egg 1.4 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Egg 1.5 CYPRINIDAE sp.

Egg 1.7 CYPRINIDAE sp.

Egg 1.6 CYPRINIDAE sp.

Egg 1.7 CYPRINIDAE sp.

Egg 1.8 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 7

ICTIOBINAE sp.

Yolk-sac 6.5 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOSINAE sp.

Yolk-sac 8.0 ICTIOBINAE sp.

Yolk-sac 7.9 D-19

APPENDIX D (coot.)

ICTIOBINAE sp.

Yolk-sac 8.6 ICTIOBINAK sp.

Yolk-sac 7.4 DARTER sp.

Yolk-sac 6.2 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 2.0 FRESHWATER DRUM Egg 1.7 SAMPLE DATE: 28 May START DATE and TIME: 28MAYI4:I9:19 SAMPLE DURATION (minutes) : 10.00 DIEL PERIOD: Day DEPTH:

ROT REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.014447 STUDY GRAB TEMPERATURE (F):

75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.5 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD: 25-31 Nay MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 10.3 Dorosoma sp.

Post Yolk-sac 10.0 Dorosoma ap.

Post Yolk-sac 7.7 Dorosoma ap.

Post Yolk-sac 7.4 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 7.7 CYPRINIDAE sp.

Yolk-sac 2.3 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Egg 1.3 CYPRINIDAE sp.

Egg 1.6 CYPRINIDAE sp.

Egg 1.3 CYPRINIDAE ap.

Egg 1.7 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAB sp.

Yolk-sac 1.5 CYPRINIDAE ap.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 2.0 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAB sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac.

8 ICTIORINAE ap.

Yolk-sac 7.4 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE sp.

Yolk-sac 7.6 ICTIOHINAE sp.

Yolk-sac 7.1 ICTIOHINAE sp.

Yolk-sac 7.4 ICTIORINAE sp.

Yolk-sac 6.8 ICTIOHINAE sp.

Yolk-sac 7.0 ICTIORINAE sp.

Yolk-sac 7.6 ICTIOBINAE sp.

Yolk-sac 8.0 ICTIOBINAE sp.

Yolk-sac 7.9 ICTIOBINAE sp.

Yolk-sac 7.5 ICTIOBINAE ap.

Yolk-sac 6.4 Morone sp.

Yolk-sac 2.7 FRESHWATER DRUM Egg 1.1 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.4 SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:19:19 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH:

ROT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.013676 STUDY GRAB TEMPERATURE (F):

75.2 STUDY GRAB DISSOLVED OXYGEN (msg/L):

8.5 FORERAY CURRENT VELOCITY (ft/sec) 1.50 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals xt i0A6) :

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Pest Yolk-sac 10.2 Dorosoma sp.

Post Yolk-sac 5.8 Dorosoma sp.

Post Yolk-sac 8.1 Dorosoma sp.

Post Yolk-sac 5.0 Dorosoma sp.

Post Yolk-sac 5.0 COMMON CARP Yolk-sac 7.1 COM*MON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.1 COMMON CARP Post Yolk-sac 9.3 CYPRINIDAE sp.

Yolk-sac 5.5 D-20

APPENDIX D (cant.)

CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAX sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Egg 1.7 CYPRINIDAE sp.

Egg 1.8 CYPRINIDAE sp.

Egg 1.7 CYPRINIDAE sp.

Egg 1.5 CYPRINIDAE sp.

Egg 1.6 CYPRINIDAE sp.

Egg 1.6 CYPRINIDAE sp.

Egg 1.8 CYPRINIDAE sp.

Egg 1.7 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE ap.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRIMIDAE sp.

Yolk-sac 2.0 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 10 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOHINAE sp.

Yolk-sac 7.1 ICTIOBINAE sp.

Yolk-sac 7.0 ICTIOBINAE sp.

Yolk-sac 7.0 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 7.1 ICTIORINAE sp.

Yolk-sac 7.5 ICTIOBINAE sp.

Yolk-sac 7.7 ICTIOBINAE ap.

Yolk-sac 7.0 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE sp.

Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 7.0 ICTIOBINAE sp.

Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 6.6 LOGPERCH type Yolk-sac 4.0 LOGPERCH type Yolk-sac 5.9 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:21:19 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH:

SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6):

0.013593 STUDY GRAB TEMPERATURE (F):

74.8 STUDY GRAB DISSOLVED OXYGEN (mag/L):

7.7 FOREBAY CURRENT VELOCITY (ft/sec):

1.70 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 10.1 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.4 COMMON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.1 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.4 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 6.7 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac.

6 CYPRINIDAE sp.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 1.9 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 1.8 D-21

APPENDIX D (cant.)

Naxastaoma sp.

Past Yalkc-sac 14.1 Naxastama sp.

Past Yalk-sac 14.7 ICTIOBINAE sp.

Yalk-sac 6.2 ICTIOBINAE ap.

Yalk-sac 6.5 ICTIOBINAE sp.

Yalk-sac 6.6 ICTIORINAE sp.

Yalk-sac 8.1 ICTIOBINAE sp.

Yalk-sac 6.3 ICTIOBINAE sp.

Yalk-sac 6.6 ICTIOBINAE ap.

Yalk-sac 7.9 ICTIOBINBE sp.

Yalk-sac 7.1 ICTIOBINAR sp.

Yalk-sac 6.9 ICTIOBINAE sp.

Yalk-sac 6.6 ICTIOBINAE sp.

Yalk-sac 7.9 ICTIOBINAE sp.

Yalk-sac 7.8 ICTIOBINAE sp.

Yalk-sac 7.0 ICTIORINAE ap.

Yalk-sac 6.9 ICTIOBINAE sp.

Yalk-sac 8.2 ICTIOBINAE sp.

Yalk-sac 7.2 ICTIOBINAE sp.

Yalk-sac 6.6 ICTIOBINAE ap.

Yalk-sac 8.2 ICTIORINAE sp.

Yalk-sac 6.7 ICTIOBINAE sp.

Yalk-sac 7.2 ICTIORINAE sp.

Yalk-sac 24 LOGPERCH type Yalk-sac 5.9 DARTER sp.

Yalk-sac 8.7 DARTER sp.

Yalk-sac 4.9 DARTER ap.

Yalk-sac 5.3 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 1.5 ROUND GORY Juvenile 7.2 ROUND GORY Juvenile 8.2 ROUND GORY Juvenile 7.1 ROUND GORY Juvenile 7.4 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.4 ROUND GORY Juvenile 7.2 ROUND GORY Juvenile 7.7 ROUND GORY Juvenile 7.1 ROUND GORY Juvenile 8.7 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.0 SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:21:19 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH:

SUR REPLICATE:

R VOLUME SAMPLED (gals x 10^6):

0.013655 STUDY GRAB TEMPERATURE (F):

14.8 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.7 FORERAY CURRENT VELOCITY (ft/see):

1.70 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT Darasama sp.

Past Yalk-sac 7.7 COMMON CARP Yalk-sac 6.7 COMMON CARP Yalk-sac 7.2 COMMON CARP Yalk-sac 7.4 COMMON CARP Yalk-sac 7.6 COMMON CARP Yalk-sac 6.8 COMMON CARP Yalk-sac 6.9 COMMON CARP Yalk-sac 6.4 COMMON CARP Yalk-sac 1.9 COMMON CARP Yalk-sac 6.4 COMMON CARP Yalk-sac 6.5 COMMON CARP Yalk-sac 6.6 COMMON CARP Yalk-sac 7.2 COMMON CARP Yalk-sac 6.7 COMMON CARP

  • Yalk-sac 8.0 CYPRINIDAE sp.

Yalk-sac 5.7 CYPRINIDAS sp.

Yalk-sac 5.7 CYPRINIDAE sp.

Yalk-sac 5.7 CYPRINIDAE sp.

Yalk-sac 1.5 CYPRINIDAE ap.

Yalk-sac 1.8 CYPRINIDAE ap.

Yalk-sac 2.6 CYPRINIDAE sp.

Yalk-sac 2.7 CYPRINIDAE sp.

Yalk-sac 2.1 CYPRINIDAE sp.

Yalk-sac 1.2 ICTIORINAE sp.

Yalk-sac 6.3 ICTIOBINBE sp.

Yalk-sac 7.2 ICTIORINAE sp.

Yalk-sac 6.7 ICTIOBINAE sp.

Yalk-sac 7.3 ICTIORINAE sp.

Yalk-sac 6.2 ICTIORINAE sp.

Yalk-sac 7.0 ICTIOBINAE ap.

Yalk-sac 6.3 ICTIORINAE ap.

Yalk-sac 7.6 ICTIORINAE ap.

Yalk-sac 7.4 ICTIOBINAE sp.

Yalk-sac 7.6 ICTIORINAE sp.

Yalk-sac 7.0 ICTIOBINAE sp.

Yalk-sac 7.1 ICTIORINBE sp.

Yalk-sac 7.7 D-22

APPENDIX D (cant.)

ICTIORINRE sp.

Yolk-sac 6.6 ICTIORINAE sp.

Yolk-sac 6.7 ICTIOBINAE sp.

Yolk-sac 6.3 ICTIORINAE ap.

Yolk-sac 6.8 ICTIORINAE sp.

Yolk-sac 7.9 ICTIORINAE ap.

Yolk-sac 6.7 ICTIORINAE ap.

Yolk-sac 6.7 ICTIORINAE sp.

Yolk-sac.-

13 PUMPKINSEED type Yolk-sac 4.5 LOGPERCN type Yolk-sac 6.4 ROUND GORY Juvenile 7.0 ROUND GORY Juvenile 7.8 ROUND GORY Juvenile 7.1 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.6 ROUND GORY Juvenile 7.2 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.1 ROUND GORY Juvenile 7.3 Morone/Pomoxis type Egg 0.9 Morone/Pomoxis type Egg 1.1 Morone/Pomoxis type Egg 1.0 Morone/Pomoxis type Egg 0.9 Morone/Pomoxis type Egg 1.i SAMPLE DATE:

28 Nay START DATE and TINE: 28MAY14:21:44 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTN: ROT REPLICATE: A VOLUME SAMPLED (gals x 10^6):

0.015853 STUDY GRAB TEMPERATURE (F):

75.0 STUDY GRAB DISSOLVED OXYGEN (mag/L) :

7.8 FORERAY CURRENT VELOCITY (ft/sec) 1.50 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 TAX Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMiMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIORINAE sp.

ICTIORINAE ap.

ICTIORINAE sp.

ICTIORINAE sp.

ICTIORINAR sp.

ICTIORINAE sp.

ICTIORINAE sp.

ICTIORINAE sp.

ICT IORINAE sp.

ICTIORINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIORINAE sp.

ICTIORINAE sp.

ICTIORINAE sp.

ICTIORINAE sp.

LIFE STAGE Post Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac LENGTN 7.2 9.0 9.1 7.1 7.2 6.6 7.5 6.9 6.4 6.7 7.5 7.0 6.5 7.1 6.6 7.8 7.5 7.4 7.7 7.2 7.6 7.7 7.5 5.7 2.0 2.1 2.0 1.7 1.8 1.5 3.0 2.6 2.7 1.6 7.5 6.3 7.4 7.6 7.0 7.1 7.4 7.4 7.2 7.7 6.7 7.4 7.3 7.2 7.2 7.2 7.0 7.2 PLUS COUNT D-23

APPENDIX D (cant.)

ICTIOHINAX sp.

Yolk-sac 7.3 ICTIORINAE sp.

Yolk-sac 6.6 ICTIOEINAE sp.

Yolk-sac 50 LOGPERCH type Yolk-sac 5.2 LOGPERCH type Yolk-sac 5.6 ROUND GORY Juvenile 7.7 ROUND GOBY Juvenile 7.1 ROUND GORY Juvenile 7.9 ROUND GORY Juvenile 7.9 ROUND GORY Juvenile 8.8 ROUND GORY Juvenile 7.7 ROUND GORY Juvenile 7.1 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.4 ROUND GORY Juvenile 7.3 SAMPLE DATE: 28 May START DATE and TINE: 28MAY14:21:44 SANPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTN: ROT REPLICATE:

B VOLUME SAMPLED (gals s 10A6):

0.014447 STUDY GRAB TEMPERATURE (F):

75.0 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.8 FORERAY CURRENT VELOCITY (ft/sea):

1.50 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 TAXA Dorosoma sp.

COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COM£MON CARP COMM4ON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMO0N CARP COMMON CARP COMMON CARP COMMO0N CARP COMMON CARP COMMO0N CARP COMMON CARP COMMON CARP COMMON CARP RLUNTNOSE MINNOW RLUNTNOSE MINNOW CYPRINIDAX sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAX sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

ICTIOBINAE ap.

ICTIOBINAE sp.

ICTIORINAX sp.

ICTIORINAE sp.

ICTIORINAE sp.

ICTIOBINAE sp.

ICTIORINAE sp.

ICTIORINAE ap.

ICTIORINAE sp.

ICTIORINAX ap.

ICTIORINAE sp.

ICTIOEINAE sp.

ICTIORINAE sp.

ICTIORINAE ap.

ICTIORINAE sp.

ICTIOEINAE ap.

ICTIORINAE sp.

ICTIOEINAX sp.

ICTIORINAE ap.

ICTIOBINAE ap.

ICTIORINAE ap.

PUMPKINSEED type FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM LIFE STAGE Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-saac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Juvenile Juvenile Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Egg Egg Egg LENGTH 7.1 7.5 7.7 6.8 7.1 6.2 6.8 7.1 7.5 6.9 7.2 7.2 7.0 7.0 6.6 6.8 7.1 7.2 6.6 7.1 7.7 6.9 7.5 13.4 16.4 5.2 5.7 2.4 2.5 1.5 2.1 1.7 2.4 2.7 2.3 2.4 2.3 6.3 6.7 7.5 6.7 7.1 7.6 7.6 7.7 7.1 6.7 7.2 7.0 6.4 6.9 7.3 7.9 7.3 8.0 8.6 7.9 4.6 1.2 1.5 1.5 PLUS COUNT 17 D-24

APPENDIX D (cant.)

FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.2 ROUND CONY Juvenile 7.6 ROUND GONY Juvenile 7.0 ROUND SONY Juvenile 7.3 ROUND GONY Juvenile 6.5 ROUND GONY Juvenile 7.7 ROUND GONY Juvenile 7.2 ROUND GOBY Juvenile 7.2 ROUND SONY Juvenile 7.5 ROUND GOBY Juvenile 8.0 Morone/Pomoxis type Egg 0.8 SAMPLE DATE:

3 June START DATE and TIME: 03JUNI4:I7:52 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.013974 STUDY GRAS TEMPERATURE (F):

77.9 STUDY CRAB DISSOLVED OXYGEN (mag/L):

9.7 FORENAY CURRENT VELOCITY (ft/sea) 1.27 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 6.7 Dorosoma sp.

Post Yolk-sac 7.0 Dorosoma sp.

Post Yolk-sac 5.8 Dorosoma sp.

Post Yolk-sac 4.7 Dorosoma sp.

Post Yolk-sac 9.2 Dorosoma sp.

Post Yolk-sac 5.2 Dorosoma sp.

Post Yolk-sac 5.8 Dorosoma sp.

Post Yolk-sac 7.2 Dorosoma sp.

Post Yolk-sac 6.0 Dorosoma sp.

Post Yolk-sac 6.9 Dorosoma sp.

Post Yolk-sac 5.7 Dorosoma sp.

Post Yolk-sac 6.7 Dorosoma sp.

Post Yolk-sac 5.3 Dorososma sp.

Post Yolk-sac 5.5 CYPRINIDAE sp.

Yolk-sac 4.8 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 2.3 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 2.0 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 121 Lepomis sp.

Post Yolk-sac 7.8 Sander sp.

Yolk-sac 8.2 FRESHWATER DRUM Post Yolk-sac 4.8 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg

1. 4 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 33 D-25

APPENDIX D (cant.)

SAMPLE DATE:

3 June START DATE and TIME:

03fUN14:17:52 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE:

H VOLUME SAMPLED (gals x 10^6):

0.014854 STUDY GRAB TEMPERATURE (F):

77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.7 FOREBAY CURRENT VELOCITY (ft/sec):

1.27 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT COMMON CARP Yolk-sac 8.0 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.9 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 2.0 CYPRINIDAE sp.

Yolk-sac 2.3 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE ap.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.9 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 53 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg

1. 6 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg.

5 SAMPLE DATE:

3 June START DATE and TIME:

O3JUN14:18:18 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: HOT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.016012 STUDY GRAB TEMPERATURE (F):

77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.7 FOREBAY CURRENT VELOCITY (ft/sec):

1.71 EXTRAPOLATION PERIOD:

1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAASTAGE LENGTH COURT Dorosoma sp.

Post Yolk-sac 5.3 Dorosoma sp.

Post Yolk-sac 5.1 Dorosoma sp.

Post Yolk-sac 4.7 Dorosoma sp.

  • Post Yolk-sac 4.5 Dorosoma sp.

Post Yolk-sac 4.4 Dorosoma sp.

Post Yolk-sac 4.7 Dorosoma sp.

Post Yolk-sac 4.6 Dorosoma sp.

Post Yolk-sac 4.5 COMMON CARP Yolk-sac 7.7 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE ap.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 2.3 CYPRINIDAE sp.

Yolk-sac 2.5 CYPRINIDAE sp.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 2.3 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.9 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAX sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.5 D-2 6

APPENDIX D (cent.)

CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac

1. 2 CYPRINIDAE sp.

Yolk-sac

1. 7 CYPRINIDAE sp.

Yolk-sac

1. 5 CYPRINIDAE sp.

Yolk-sac 73 CYPRINIDAE sp.

Yolk-sac 29 CYPRINIDAE sp.

Yolk-sac 49 PUMPKINSEED type Yolk-sac 4.2 DARTER ap.

Yolk-sac 9.5 DARTER ap.

Yolk-sac 9.7 DAIRTER Sp.

Yolk-sac 6.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg

1. 4 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg
1. 2 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg
1. 2 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg
1. 2 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg
1. 2 FRESHWATER DRUM Egg 12 SAMPLE DATE:

3 June START DATE and TIME:

O3JUN14:18:18 SAMPLE DURATION (minutes) :

9.00 DIEL PERIOD: Day DEPTH: HOT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.014314 STUDY GRAB TEMPERATURE (F):

77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.7 FOREBAY CURRENT VELOCITY (ft/sec):

1.71 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 TAXA.

Dorosoma sp.

Dorosoms ap.

COMMON CARP CYPRIMIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIOAE sp.

CYPRINIDAE sp.

CYPRINIOAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRIMIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIOAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIOAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

PUMPKINSEED type FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM LIFE STAGE Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg LENGTH 4.7 4.9 7.6 5.2 5.0 5.1 5.3 1.8 2.2 1.7 2.4 2.5 2.2 1.7 1.8 2.6 2.4 2.2 2.5 2.2 2.6 2.2 1.5 2.7 2.0 2.3 2.0 4.0 1.6 1.4 1.5 1.5 1.3 1.2 1.3 1.2 1.4 1.5 1.2 1.3 1.3 1.3 1.4 1.7 1.5 PLUS COUNT 25 0-27

APPENDIX D (cant.)

FRESHWATER DRUM Egg

1. 2 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg.

S SAMPLE DATE:

3 June START DATE and TIME: 03JUN14:20:38 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE:

A VOLUME SAMPLED (gals x 10a6):

0.013872 STUDY GRAB TEMPERATURE (F):

77.2 STUDY GRAS DISSOLVED OXYGEN (mg/L):

8.5 FORERAY CURRENT VELOCITY (ft/sea):

1.80 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 7.2 Dorosoma sp.

Post Yolk-sac 7.8 Dorosoma ap.

Post Yolk-sac 10.2 Dorosoma sp.

Post Yolk-sac 5.5 Dorosoma sp.

Post Yolk-sac 8.9 Dorosoma sp.

Post Yolk-sac 8.1 Dorosoma sp.

Post Yolk-sac 9.1 Dorosoma ap.

Post Yolk-sac 5.8 Dorosoma sp.

Post Yolk-sac 5.1 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 7.5 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 4.7 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.8 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE ap.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRIHIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.7 CYPRINIDAE ap.

Yolk-sac 2.5 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 2.7 CYPRINIDAE ap.

Yolk-sac 2.3 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.3 CYPRINIDAE sp.

Yolk-sac 3.2 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE ap.

Yolk-sac.

6 Moxostoma sp.

Post Yolk-sac 12.6 BLUEGILL type Post Yolk-sac 5.3 BLUEGILL type Post Yolk-sac 5.7 BLUEGILL type Post Yolk-sac 5.4 DARTER sp.

Yolk-sac 6.9 DARTER sp.

Yolk-sac 7.4 DARTER sp.

Yolk-sac 6.6 FRESHWATER DRUM Yolk-sac 3.8 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 14 FRESHWATER DRUM Yolk-sac 3.8 D-28

APPENDIX D (cant.)

SAMPLE DATE: 3 June START DATE and TINE: 03JUN14:20:36 SAMPLE DURATION (minutes) : 10.00 DIEL PERIOD: Night DEPTH:

SUR REPLICATE:

H VOLUME SANPLED (gals x 10A6):

0.013382 STUDY GRAB TEMPERATURE (F):

17.2 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

8.5 FOREBAY CURRENT VELOCITY (ft/sea) :

1.80 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAASTAGE LENGTH COUNT Dorosoxsa sp.

Post Yolk-sac 5.0 COMMON CARP Yolk-sac 8.8 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.7 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 3.1 CYPRINIDAE ap.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 3.2 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 2.7 CYPRINIDAE sp.

Yolk-sac 2.7 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRIMIDAE sp.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 3.2 CYPRINIDAE sp.

Yolk-sac 2.3 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 3.2 CYPRINIDAE sp.

Yolk-sac.

7 ICTIOBINAE sp.

Yolk-sac 9.7 PUMPEINSEED type Yolk-sac 6.5 FRESHWATER DRUM Egg

1. 3 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg.

4 SAMPLE DATE: 3 June START DATE and TIME:

03JUN14:21:02 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: HOT REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.015820 STUDY GRAB TEMPERATURE (F) :

77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.4 FOREBAY CURRENT VELOCITY (ft/sac) 1.70 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 8.3 Dorosoma sp.

Post Yolk-sac

  • 5.9 Dorosoma sp.

Post Yolk-sac 5.2 Dorosomsa sp.

Post Yolk-sac 8.7 Dorosoma sp.

Post Yolk-sac 8.9 Dorosoma sp.

Post Yolk-sac 5.4 Dorosoma sp.

Post Yolk-sac 8.2 Dorosoma sp.

Post Yolk-sac 4.5 Dorosoma sp.

Post Yolk-sac 7.9 Dorosoma sp.

Post Yolk-sac 7.9 Dorosoma sp.

Post Yolk-sac 7.9 Dorosoma sp.

Post Yolk-sac 6.6 Pimsephales type Yolk-sac 5.9 Pimiephales type Yolk-sac 5.0 Pimeephales type Yolk-sac 5.0 Pixsephales type Yolk-sac 5.4 Pixsephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 4.9 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.7 D-29

APPENDIX D (cont.)

Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 4.8 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 4.8 Pismephales type Yolk-sac 5.0 Pimsephales type Yolk-sac 5.0 Pimephales type Yolk-sac 11 Semsotilus type Yolk-sac 8.0 CYPRINIDAE sp.

Yolk-sac 5.0 CYPRINIDAE sp.

Yolk-sac 5.1 CYPRINIDAE sp.

Yolk-sac 5.0 CYPRINIDAE ap.

Yolk-sac 5.0 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 4.9 CYPRIMIDAE sp.

Yolk-sac 5.0 CYPRINIDAE ap.

Yolk-sac 5.2 CYPRINIDAS sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 4.8 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.7 CYPRINIDAS sp.

Yolk-sac 2.5 CYPRINIDAE sp.

Yolk-sac 2.5 CYPRINIDAE sp.

Yolk-sac 2.0 CYPRINIDAE sp.

Yolk-sac 3.0 CYPRINIDAE sp.

Yolk-sac 3.0 CYPRINIDAE sp.

Yolk-sac 3.1 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRIMIDAE sp.

Yolk-sac 2.7 CYPRINIDAE sp.

Yolk-sac 2.7 CYPRIMIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 3.0 CYPRINIDAE sp.

Yolk-sac 2.7 CYPRINIDAS sp.

Yolk-sac 1.9 CYPRINIDAE sp.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.5 CYPRINIDAE ap.

Yolk-sac 43 PUMPKINSEED type Yolk-sac 5.0 LOOPERCH type Yolk-sac 5.5 DARTER sp.

Post Yolk-sac 13.4 DARTER ap.

Yolk-sac 7.2 DARTER sp.

Yolk-sac 6.9 FRESHWATER DRUM Egg

1. 3 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.1 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.1 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg
1. 2 FRESHWATER DRUM Egg
1. 2 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 11 ROUND GOBY Juvenile 7.3 ROUND GOBY Juvenile 7.6 ROUND GOBY Juvenile 7.2 ROUND GOBY Juvenile 7.4 ROUND GOBY Juvenile 7.4 ROUND GOBY Juvenile 7.8 ROUND GOBY Juvenile 7.7 ROUND GOBY Juvenile 7.6 ROUND GOSY Juvenile 7.4 ROUND GOBY Juvenile 7.4 ROUND GOBY Juvenile 7.7 ROUND GOBY Juvenile 7.7 ROUND GOBY Juvenile 7.4 ROUND GOBY Juvenile 7.6 ROUND GOBY Juvenile 7.1 ROUND GOBY Juvenile 7.5 ROUND GOBY Juvenile 6.9 ROUND GOBY Juvenile 7.4 ROUND GOBY Juvenile 7.4 D-30

APPENDIX D (cont.)

SAMPLE DATE:

3 June START DATE and TIME: 03JUNI4:21:01 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: EDT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.014004 STUDY GRAB TEMPERATURE (F):

77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.4 FORERAY CURRENT VELOCITY (ft/sec):

1.70 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 5.0 Dorosoma sp.

Post Yolk-sac 7.2 Dorosoma sp.

Post Yolk-sac 5.1 COM£MON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.0 BLUNTNOSE MINNOW Post Yolk-sac 16.6 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 4.9 Pimephales type Yolk-sac 5.5 Pimnephales type Yolk-sac 5.4 Pimephales type Yolk-sac 4.9 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 4.9 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 6.7 CYPRINIDAE ap.

Yolk-sac 2.9 CYPRINIDAS ap.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.4 CYPRINIDAS sp.

Yolk-sac 2.7 CYPRINIDAE sp.

Yolk-sac 2.7 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 3.2 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 3.0 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac.

8 CYPRINIDAE ap.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 2.3 Noxostoma sp.

Post Yolk-sac 17.0 ICTIOBINAE sp.

Post Yolk-sac 7.9 DARTER sp.

Yolk-sac 6.5 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg

1. 5 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg
1. 5 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg,
1. 5 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg.

S FRESHWATER DRUM Yolk-sac 2.5 ROUND GORY Juvenile 7.4 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.3 ROUND GORY Juvenile 7.6 ROUND GORY Juvenile 7.4 ROUND GORY Juvenile 7.7 ROUND GORY Juvenile 7.2 ROUND GORY Juvenile 7.0 ROUND GORY Juvenile 7.3 ROUND GORY Juvenile 7.4 ROUND GORY Juvenile 7.3 UNIDENTIFIED Yolk-sac 1.9 UNIDENTIFIED Yolk-sac 2.3 UNIDENTIFIED Yolk-sac 1.9 D-31

APPENDIX D (cant.)

SAMPLE DATE: 11 June START DATE and TIME: 1lJUN14:lS:00 SAMPLE DURATION (minutes) :

14.00 DIEL PERIOD: Day DEPTH:

SUn REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.013635 STUDY GRAB TEMPERATURE (F):

72.1 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

7.7 FOREBAY CURRENT VELOCITY (ft/sec):

1.00 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAASTAGE LERGTH COUNT COMMON CARP Egg 1.5 COMRMON CARP Egg 1.3 COMMON CARP Egg 1.5 COMMON CARP Egg

1. 5 COMMON CARP Egg
1. 4 COMMON CARP Egg 1.3 COMMON CARP Egg
1. 5 COMMON CARP Egg
1. 5 COMMON CARP Egg
1. 4 COMMON CARP Egg
1. 4 COMMON CARP Egg
1. 0 COMMON CARP Egg
1. 6 COMMON CARP Egg
1. 5 COMMON CARP Egg 1.6 COMMON CARP Egg
1. 5 COMMON CARP Egg
1. 5 COMMON CARP Egg 1.4 COMMON CARP Egg
1. 0 COMMON CARP Egg
1. 1 COMMON CARP Egg 1.7 COMMON CARP Egg 46 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.7 Pimsephales type Yolk-sac 5.1 Pimsephales type Yolk-sac 5.2 Pimephales type Yolk-sac 6.2 Pimephales type Post Yolk-sac 9.6 Pimephales type Post Yolk-sac 10.4 CYPRINIDAE sp.

Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 6.1 Moxostoma sp.

Post Yolk-sac 12.2 ROCK BASS Post Yolk-sac 10.3 LOGPERCH type Yolk-sac 5.2 SAMPLE DATE:

11 June START DATE and TIME: 11JUN14:17:32 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE:

B VOLUME SAMPLED (gals x i0A6):

0.014296 STUDY GRAB TEMPERATURE (F):

72.1 STUDY GRAB DISSOLVED OXYGEN (rag/L):

7.7 FOREBAY CURRENT VELOCITY (ft/sac) 1.00 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 10.7 Dorosoma ap.

Post Yolk-sac 15.1 Dorosoma sp.

Post Yolk-sac 10.6 Dorosoma sp.

Post Yolk-sac 7.1 COMMON CARP Egg 1.4 COMMON CARP Egg

1. 4 COMMON CARP Egg
1. 4 COMMON CARP Egg
1. 5 COMMON CARP Egg 1.6 COMMON CARP Egg 1.5 COMMON CARP Egg 1.5 COMMON CARP Egg
1. 4 COMMON CARP Egg 1.4 COMMON CARP Egg 1.6 COMMON CARP Egg 1.5 COMMON CARP Egg
1. 5 COM£MON CARP Egg
1. 5 COMMON CARP Egg
1. 4 COMMON CARP Egg
1. 4 COM*MON CARP Egg
1. 4 COMMON CARP Egg
1. 5 COMMON CARP Egg 1.6 COMMON CARP Egg 1.4 COMMON CARP Egg 1.6 COMMON CARP Egg 58 CYPRINIDAE sp.

Post Yolk-sac 6.7 CYPRINIDAE sp.

Post Yolk-sac 5.9 CYPRINIDAE sp.

Post Yolk-sac 6.3 CYPRINIDAE sp.

Post Yolk-sac 6.3 CYPRINIDAE sp.

Post Yolk-sac 6.6 D-32

APPENDIX D (cont.)

CYPRINIDRE sp.

Post Yolk-sac 5.8 CYPRINIDAE sp.

Post Yolk-sac 6.6 CYPRINIDAE ap.

Post Yolk-sac 6.9 CYPRINIDAE sp.

Post Yolk-sac 5.8 CYPRINIDAS sp.

Post Yolk-sac 6.3 CYPRINIDAB sp.

Yolk-sac 4.8 CYPRINIDAS sp.

Yolk-sac 4.6 CYPRINIDAX sp.

Yolk-sac 4.8 Moxostoma sp.

Post Yolk-sac 13.0 LOGPERCH type Yolk-sac 5.7 LOGPERCN type Yolk-sac 5.8 DARTER sp.

Post Yolk-sac 13.4 DARTER sp.

Post Yolk-sac 9.7 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.7 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg

1. 4 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.1 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg.

9 SAMPLE DATE:

11 June START DATE and TIME: I1JUN14:I8:05 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Day DEPTH: HOT REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.013728 STUDY GRAB TEMPERATURE (F):

71.8 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.8 FOREBAY CURRENT VELOCITY (ft/sec):

1.46 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 TARA GAR sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

COMMON CARP COMMON CARP COMMON CARP COMMON CARP COM£MON CARP COMMON CARP COMiMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAB sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRIHIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

PUMPKINSEED type LIFE STAGE Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac LENGTH 26.1 6.2 10.2 13.5 8.3 8.2 15.2 10.2 5.5 6.6 4.5 1.4 1.5 1.6 1.5 1.5 1.4 1.5 1.6 1.6 1.5 1.5 1.0 1.4 1.i 1.5 1.2 1.2 1.5 1.6 1.5 5.7 5.9 5.8 5.2 5.0 5.0 5.7 6.0 8.2 6.2 5.8 5.7 PLUS COURT 31 D-33

APPENDIX D (cant.)

LOGPERCH type Yolk-sac 6.1 LOGPERCH type Yolk-sac 5.0 DARTER sp.

Yolk-sac 8.5 DARTER sp.

Post Yolk-sac 7.5 DARTER sp.

Post Yolk-sac 10.8 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 0.8 FRESHWATER DRUM Egg 0.9 FRESHWATER DRUM Egg 1.1 FRESHWATER DRUM Egg 1.2 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.3 ROUND COBY Juvenile 7.7 UNIDENTIFIED Yolk-sac 2.9 SAMPLE DATE: 11 June START DATE and TINE: 1IJUNI4:18:33 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Day DEPTH: ROT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.015437 STUDY GRAB TEMPERATURE (F):

71.8 STUDY GRAB DISSOLVED OXYGEN (msg/L):

7.8 FORERAY CURRENT VELOCITY (ft/sac):

1.46 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 TAXA Dorosoma sp.

Dorosoma sp.

Dorosoma ap.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COM1MON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP Pimephales type Pimephales type Piisephales type Pimephales type CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

PUMPEINSEED type PUNPEINSEED type DARTER sp.

FRESHWATER DRUM FRESHWATER DRUM LIFE STAGE Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Egg Egg LENGTH 7.6 15.2 13.7 10.5 8.7 8.8 7.4 5.1 1.4 1.4 1.5 1.1 1.0 1.4 1.4 1.0 1.4 1.2 1.3 1.2 1.2 1.3 1.0 1.0 1.3 1.0 1.1 1.1 5.9 6.2 5.6 5.7 6.6 7.0 6.6 8.2 6.6 6.7 6.6 6.4 5.9 5.8 6.8 6.4 7.9 6.3 6.7 6.0 6.2 6.5 6.8 7.0 5.5 5.7 4.7 5.2 13.8 1.5 1.5 PLUS COUNT 59 D-34

APPENDIX D (cont.)

FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.4 SAMPLE DATE:

11 June START DATE and TINE: llJUNl4:20:43 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.013742 STUDY GRAS TEMPERATURE (F):

71.4 STUDY GRAB DISSOLVED OXYGEN (msg/L):

7.4 FORESAY CURRENT VELOCITY (ft/sec):

1.00 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAXA STAGE LENGTH COURT Dorosoma sp.

Post Yolk-sac 4.3 Dorosoma sp.

Post Yolk-sac 5.2 Dorosoma ap.

Post Yolk-sac 6.6 Dorosoma sp.

Post Yolk-sac 10.1 Dorosoma sp.

Post Yolk-sac 10.7 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 7.5 COMMON CARP Yolk-sac 7.3 COMMON CARP Yolk-sac 5.7 COMMON CARP Yolk-sac 6.4 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 5.9 COMMON CARP Egg 1.2 COMMON CARP Egg 1.3 COMMON CARP Egg 1.2 COMMON CARP Egg 1.3 COM£MON CARP Egg 1.5 COMMON CARP Egg 1.0 COMMO0N CARP Egg 1.1 COMMON CARP Egg 1.4 COMMON CARP Egg 1.0 COMMON CARP Egg 1.0 COMMON CARP Egg 1.0 COMMON CARP Egg 1.2 COMMON CARP Egg 1.1 COM£MON CARP Egg 1.4 COMMON CARP Egg 1.4 COMMON CARP Egg 1.3 COMMON CARP Egg

1. 4 COMMON CARP Egg
1. 3 COMMON CARP Egg
1. 5 COMMON CARP Egg 1.4 COMMON CARP Egg 11 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 4.9 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 4.8 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRINIDAB sp.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 6.1 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.1 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRINIDAB sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAE ap.

Yolk-sac 6.1 CYPRINIDAE ap.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE ap.

Yolk-sac 5.0 CYPRINIDAE sp.

Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 5.4 Noxostoma sp.

Post Yolk-sac 14.7 ICTIOBINAE sp.

Post Yolk-sac 20.2 PUMPKINSEED type Yolk-sac 5.8 LOGPERCH type Yolk-sac 5.3 DARTER sp.

Yolk-sac 8.7 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.3 ROUND GOBY Juvenile 8.9 D-35

APPENDIX D (cont.)

SAMPLE DATE:

11 June START DATE and TIME: llJUNl4:20:43 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Night DEPTH:

SUN REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.017308 STUDY CRAB TEMPERATURE (F):

71.4 STUDy CRAB DISSOLVED OXYGEN (rag/L) :

7.4 FORENAY CURRENT VELOCITY (ft/sec) 1.00 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 106) :

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorososma sp.

Post Yolk-sad 7.2 Dorosoma sp.

Post Yolk-sac 7.0 Dorosoma sp.

Post Yolk-sac 9.2 Dorosoma sp.

Post Yolk-sac 10.2 Dorosoma sp.

Post Yolk-sac 12.0 Dorosoma sp.

Post Yolk-sac 15.7 Dorosoma sp.

Post Yolk-sac 8.3 Dorosoma sp.

Post Yolk-sac 12.2 Dorosoma sp.

Post Yolk-sac 9.1 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 6.9 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 5.8 COMMON CARP Yolk-sac 5.4 COMMON CARP Yolk-sac 5.3 COMMON CARP Egg

1. 4 COMMON CARP Egg
1. 4 COMMON CARP Egg
1. 5 COMMON CARP Egg
i. 1 COMMON CARP Egg
1. 6 COM*MON CARP Egg
1. 3 COMMON CARP Egg
1. 4 COMMON CARP Egg
i. 1 COMMON CARP Egg
1. 1 COMMON CARP Egg
1. 2 COMMON CARP Egg
1. 3 COMMON CARP Egg
1. 6 COMMON CARP Egg
1. 2 COMMON CARP Egg
1. 5 COMMON CARP Egg
1. 3 COMMON CARP Egg
1. 3 COMMON CARP Egg
1. 3 COMMON CARP Egg
1. 4 COMMON CARP Egg 1.6 Pimephales type Yolk-sac 4.7 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.4 Pimnephales type Yolk-sac 5.6 Pimephales type Yolk-sac 4.9 Semotilus type Post Yolk-sac 12.2 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIOAE sp.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAS sp.

Yolk-sac 4.5 CYPRINIDAS sp.

Yolk-sac 4.7 CYPRINIDAE sp.

Yolk-sac

1. 6 CYPRINIDAS sp.

Yolk-sac

1. 2 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac

1. 6 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAS sp.

Yolk-sac

1. 3 DARTER sp.

Yolk-sac 8.2 DARTER sp.

Post Yolk-sac 16.5 FRESHWATER DRUM Egg

1. 6 FRESHWATER DRUM Egg
i. 5 FRESHWATER DRUM Egg
1. 5 ROUND CONY Juvenile 7.2 ROUND GORY Juvenile 13.4 ROUND CONY Juvenile
11. 8 SAMPLE DATE:

11 June START DATE and TIME: IIJDNI4:21:12 SAMPLE DURATION (minutes) : 13.00 DIEL PERIOD: Night DEPTH:

NOT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.014231 STUDY GRAB TEMPERATURE (F) :

71.4 STUDY GRAB DISSOLVED OXYGEN (rag/L) :

7.3 FORENAY CURRENT VELOCITY (ft/sec) 1.55 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAXA STAGE LENGTH COURT Dorosoma sp.

Post Yolk-sac 13.6 Dorosoma sp.

Post Yolk-sac 8.9 Dorosomia sp.

Post Yolk-sac 8.2 Dorosoma sp.

Post Yolk-sac 11.7 Dorosoma sp.

Post Yolk-sac 13.3 COMMON CARP Yolk-sac 6.6 COMMON CARP Yolk-sac 6.4 D-36

APPENDIX D (cont.)

COMMON CARP Yolk-sac 5.6 COMMO0N CARP Yolk-sac 5.5 COMMON CARP Yolk-sac 7.4 COMM4ON CARP Egg

1. 1 COMMON CARP Egg
1. 5 COMMON CARP Egg
1. 1 COMMON CARP Egg
1. 3 COMMON CARP Egg
1. 4 COMMON CARP Egg 1.4 COMMON CARP Egg 1.2 COMMON CARP Egg 1.3 COMMON CARP Egg 1.3 COMMON CARP Egg 1.2 Pimephales type Yolk-sac 6.0 Pixmephales type Yolk-sac 6.1 Pimsephales type Yolk-sac 4.9 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 4.8 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 7.2 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac

1. 5 CYPRINIDAE sp.

Yolk-sac

1. 4 CYPRINIDAB sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac

1. 7 CYPRINIDAE sp.

Yolk-sac

1. 3 CYPRINIDAE sp.

Yolk-sac

1. 5 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 1.2 Noxostoma sp.

Post Yolk-sac 12.4 Moxostoma sp.

Post Yolk-sac 13.7 Moxostoma sp.

Post Yolk-sac 14.9 DARTER sp.

Post Yolk-sac 9.8 FRESHWATER DRUM Egg 1.4 ROUND GORY Juvenile 7.7 ROUND CONY Juvenile 6.9 ROUND CONY Juvenile 7.9 ROUND CONY Juvenile 7.4 ROUND COBY Juvenile 7.7 ROUND GOBY Juvenile 7.5 ROUND GOBY Juvenile 15.3 ROUND GOBY Juvenile 17.7 SAMPLE DATE:

11 June START DATE and TIME:

lIJUNI4:21:12 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.013914 STUDY GRAB TEMPERATURE (F):

71.4 STUDY GRAB DISSOLVED OXYGEN (msg/L) :

7.3 FOREBAY CURRENT VELOCITY (ft/sec):

1.55 EXTRAPOLATION PERIOD: 8-14 June NAXEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 10.7 Dorosoma sp.

Post Yolk-sac 11.3 Dorosoma sp.

Post Yolk-sac 8.2 COMMON CARP Yolk-sac 5.6 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.7 COMMON CARP Egg 1.1 COMMON CARP Egg 1.0 COMMON CARP Egg 1.0 COMMON CARP Egg 1.3 COMMON CARP Egg 1.4 COMMON CARP Egg 1.4 COMMON CARP Egg 1.1 COMMON CARP Egg 1.1 COMMON CARP Egg 1.3 COMMON CARP Egg 1.5 COMMON CARP Egg 1.3 Pimephales type Yolk-sac "4.8 Pimephales type Yolk-sac 4.9 Pimsephales type Yolk-sac 5.5 CYPRINIDAE sp.

Yolk-sac 5.9 CYPRINIDAX sp.

Yolk-sac 7.2 CYPRINIDAE sp.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 1.7 D-37

APPENDIX D (cont.)

CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 2.0 CYPRINIDAE sp.

Yolk-sac 1.5 ROCK BASS Post Yolk-sac 7.5 DARTER sp.

Post Yolk-sac 13.1 DARTER sp.

Post Yolk-sac 12.3 DARTER ap.

Past Yolk-sac 10.0 FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.3 ROUND GORY Juvenile 7.2 ROUND GORY Juvenile 7.0 ROUND GORY Juvenile 7.3 ROUND GORY Juvenile 7.0 ROUND GORY Juvenile 8.0 ROUND GORY Juvenile 7.9 ROUND GORY Juvenile 7.7 ROUND GORY Juvenile 21.5 SAMPLE DATE: 17 June START DATE and TIME: 17JUN14:17:30 SAMPLE DURATION (minutes): 21.00 DIEL PERIOD:

Day DEPTH: SUE REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.013897 STUDY GRAB TEMPERATURE (F):

77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.5 FOREBAY CURRENT VELOCITY (ft/sec) 1.00 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosomsa sp.

Post Yolk-sac 5.4 Dorosoma sp.

Post Yolk-sac 5.3 Dorosoma sp.

Post Yolk-sac 5.2 Dorosoma sp.

Post Yolk-sac 6.0 Dorosoma sp.

Post Yolk-sac 5.5 COMMON CARP Egg 1.4 COMMON CARP Egg 1.5 COMMON CARP Egg 1.5 COMMON CARP Egg 1.4 COMMON CARP Egg

1. 2 COMMON CARP Egg
1. 2 Pimephales type Yolk-sac 6.4 Pimephales type Yolk-sac 7.0 Plisephales type Yolk-sac 5.2 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 4.9 Pixuephales type Yolk-sac 5.3 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 6.3 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.6 Pimnephales type Yolk-sac 6.2 Pimephales type Yolk-sac 5.3 Pimsephales type Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 5.8 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 7.0 CYPRIMIDAE sp.

Yolk-sac 6.3 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRINIDAE sp.

Yolk-sac 6.1 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAX sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAS sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 1.2 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE ap.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE ap.

Yolk-sac 2.8 CYPRINIDAE ap.

Yolk-sac 71 DARTER sp.

Yolk-sac 7.1 DARTER sp.

Yolk-sac 6.8 D-38

APPENDIX D (cant.)

SAMPLE DATE:

17 June START DATE and TINE: 17JUNl4:17:30 SAMPLE DURATION (minutes): 17.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.013677 STUDY GRAB TEMPERATURE (F):

77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.5 FOHEBAY CURRENT VELOCITY (ft/sec):

1.00 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTH COURT Dorosoma ap.

Yolk-sac 6.6 Dorosoma sp.

Yolk-sac 6.5 Dorosoma sp.

Yolk-sac 7.4 Dorosoma sp.

Yolk-sac 6.7 Dorosoma sp.

Yolk-sac 7.7 Dorosoma sp.

Post Yolk-sac 11.8 Dorosoma sp.

Post Yolk-sac 9.1 Dorosoma sp.

Yolk-sac 5.7 Dorosoma sp.

Post Yolk-sac 11.9 Dorosoma sp.

Yolk-sac 6.2 Dorosoma sp.

Yolk-sac 6.7 Dorosoma sp.

Yolk-sac 6.6 Dorosoma sp.

Yolk-sac 5.6 Dorosoma sp.

Yolk-sac 5.9 Dorosoma ap.

Yolk-sac 7.0 Dorosomsa sp.

Yolk-sac 6.1 Dorosomsa sp.

Yolk-sac 5.2 Dorosoma sp.

Yolk-sac 5.9 COMMON CARP Yolk-sac 7.3 COMMON CARP Egg

1. 2 COMMON CARP Egg
1. 3 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 6.3 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.0 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac.

4 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 1.3 CYPRINIDAE sp.

Yolk-sac 1.7 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRIHIDAE sp.

Yolk-sac 1.9 CYPRINIDAE sp.

Yolk-sac 2.1 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.5 CYPRINIDAE sp.

Yolk-sac 1.6 CYPRINIDAE sp.

Yolk-sac 2.4 CYPRINIDAE sp.

Yolk-sac 1.9 CYPRINIDAE sp.

Yolk-sac.

49 ICTIOBINAE sp.

Yolk-sac 6.2 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE ap.

Yolk-sac 7.5 ICTIOBINAE sp.

Yolk-sac 6.2 ICTIOBINAE sp.

Yolk-sac 6.3 ICTIOBINAE sp.

Yolk-sac 6.6 ICTIOBINAE sp.

Yolk-sac 7.3 ICTIOBINAE sp.

Yolk-sac 6.1 Lepomis sp.

Post Yolk-sac 6.1 DARTER sp.

Yolk-sac 6.6 FRESHWATER DRUM Yolk-sac 3.9 SAMPLE DATE:

17 June START DATE and TINE: 17JUN14:18:07 SAMPLE DURATION (minutes): 18.00 DIEL PERIOD: Day DEPTH: HOT REPLICATE:

A VOLUME SAMPLED (gals x 10^~6):

0.013563 STUDY GRAB TEMPERATURE (F):

77.5 STUDY GRAB DISSOLVED OXYGEN (msg/L):

9.5 FOREBAY CURRENT VELOCITY (ft/sec):

1.53 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAX STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 7.2 Dorosoma sp.

Post Yolk-sac 6.3 Dorosoma sp.

Post Yolk-sac 10.1 D-39

APPENDIX 0 (cant.)

Dorosonia sp.

Dorosoma sp.

Dorosomsa sp.

COMMON CARP COMMON CARP COMMON CARP COM*MON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP Pimlephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimeephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimsephales type Pimuephales type Pimsephales type CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAS sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

ICTIOHINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

PUMPKINSEED type PUNPKINSEED type DARTER sp.

DARTER sp.

FRESNWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM Post Yolk-sac Post Yolk-sac Post Yolk-sac Egg Egg Egg Egg Egg Egg Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sec Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Yolk-sac Egg Egg Egg Egg

12. 1 10.9 16.5 1.3 1.2 1.4 1.4 1.5 1.4 1.3 7.6 6.4 5.5 5.7 6.1 5.2 5.7 6.1 6.2 5.8 5.7 6.1 6.2 6.2 5.6 5.2 6.5 5.9 5.7 5.8 5.7 5.9 5.9 1.2 1.2 1.7 1.4 1.4 1.3 1.2 1.2 1.8 1.2 1.4 1.5 1.8 1.7 1.2 1.3 2.0 1.4 1.7 1.5 6.2 5.9 5.3 6.2 5.0 6.2 5.8 6.0 5.5 5.6 5.6 5.8 5.5 6.0 6.1 5.9 6.0 6.2 5.9 5.5 6.3 6.8 6.6 5.7/

5.3 13.4 8.8 1.4 1.3 1.4 1.4 D-40

APPENDIX D (cant.)

FRESHW*ATER DRUM Egg 2.1 FRESHW4ATER DRUM Egg

1. 9 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 4 FRESHWATER DRUM Egg
1. 6 FRESHWATER DRUM Egg
1. 3 FRESHrWATER DRUM Egg
1. 3 FRESHWATER DRUM Egg 1.7 UNIDENTIFIED Yolk-sac 3.9 SAMPLE DATE:

17 June START DATE and TIME: 17JUN14:18:07 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD:

Day DEPTH: EOT REPLICATE:

B VOLUME SAMPLED (gals x 10A8) :

0.013734 STUDY GRAB TEMPERATURE (F):

77.5 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

9.5 FOREBAY CURRENT VELOCITY (ft/sea) 1.53 EXTRAPOLATION PERIOD: 15-21 June MAXEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x i0A6) :

604.8 TAXA Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

COMMON CARP COMMON CARP Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Piisephales type Pimtephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Piisephales type Pimsephales type Pimiephales type Pimephales type Pixmephales type CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE spt CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAX sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAX sp.

CYPRINIDAX sp.

CYPRINIDAX sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAX sp.

CYPRINIDAE sp.

CYPRINIDAX sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAX ap.

CYPRINIDAX sp.

LIFE STAGE Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Egg Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac LENGTH ii.i 10.0 6.6 6.1 10.1 6.8 6.4 6.2 4.7 6.8 9.5 1.3 1.4 5.3 5.2 5.0 5.0 6.0 5.8 5.9 5.7 5.4 5.8 4.7 6.4 5.2 4.9 4.7 5.2 6.0 6.1 5.7 6.2 5.6 5.3 5.7 6.1 6.3 6.0 6.0 8.0 6.2 5.3 5.5 5.3 6.0 5.8 6.0 1.4 1.2 2.1 1.9 2.1 2.2 1.8 1.4 2.2 1.3 1.3 1.4 1.9 1.7 1.2 1.2 2.5 1.6 1.3 1.5 PLUS COUNT 11 D-41

APPENIX U

cant.

CYPRINIDAE sp.

Yolk-sac 51 ICTIOBINAE sp.

Yolk-sac 6.4 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOBINAE sp.

Yolk-sac 6.9 ICTIOBINAE sp.

Yolk-sac 6.4 PUMPEINSEED type Yolk-sac 5.7 DARTER sp.

Yolk-sac 7.4 DARTER sp.

Yolk-sac 7.2 DARTER sp.

Yolk-sac 6.9 DARTER sp.

Post Yolk-sac 10.0 SAMPLE DATE:

17 June START DATE and TIME: 17JUNI4:20:32 SAMPLE DURATION (minutes) :

15.00 DIEL PERIOD: Night DEPTH:

SUR REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.013794 STUDY GRAB TEMPERATURE (F) :

77.2 STUDY GRAB DISSOLVED OXYGEN (mag/L) :

8.3 FOREBAY CURRENT VELOCITY (ft/sec) 1.00 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 TAXA Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

COMMON CARP COMMON CARP COMMON CARP Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimnephales type Pimnephales type Pimephales type Piinephales type Pimephales type Pimephales type CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRIHIDAE sp.

CYPRIHIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE,* sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

ICTIOBINAR sp.

PUMPEINSEED type LOGPERCH type LOGPERCH type DARTER sp.

DARTER sp.

DARTER sp.

DARTER sp.

LIFE STAGE Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Egg Egg Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac LEGTH 6.1 9.4 8.5 7.7 8.1 6.4 1.2 1.4 1.3 5.2 4.7 5.6 4.8 5.9 5.3 5.6 5.8 5.1 6.3 5.4 5.5 5.1 5.3 6.1 6.1 5.6 5.0 5.9 5.2 6.1 5.3 5.1 5.6 5.1 6.4 6.3 6.3 5.3 5.6 5.3 5.2 5.9 5.3 2.2 2.7 3.0 2.8 1.8 2.6 2.8 2.5 1.5 2.2 2.7 2.5 1.9 2.7 2.3 2.4 2.8 7.7 5.6 6.7 6.3 7.5 7.0 7.2 7.2 PLUS COUNT D-42

APPENIX D

cant.

DARTER sp.

Yolk-sac 6.8 DARTER sp.

Yolk-sac 6.1 DARTER ap.

Yolk-sac 6.3 FRESHWATER DRUM Post Yolk-sac 9.7 FRESHWATER DRUM Post Yolk-sac 7.3 FRESHWATER DRUM Post Yolk-sac 7.4 FRESHWATER DRUM Egg 1.3 FRESHWATER DRUM Egg 1.4 FRESHWATER DRUM Egg 1.5 SAMPLE DATE: 17 June START DATE and TIME: 17J0NI4:20:32 SAMPLE DURATION (minutes) : 17.00 DIEL PERIOD: Might DEPTH:

SUR REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.013818 STUDY GRAB TEMPERATURE (F) :

77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

8.3 FOREBAY CURRENT VELOCITY (ft/sec) 1.00 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x i0A6) :

604.8 TAX Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosomsa sp.

Dorosoma sp.

Dorosomsa sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma ap.

COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP Pimephales type Pimephales type Pimephales type Pimsephales type Pimuephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type CYPRINICAE sp.

CYPRINIDAE sp.

CYPRINIOAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIOAE sp.

CYPRINIUAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINICAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAK sp.

CYPRINIflAE sp.

CYPRINIflAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIOAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

LIFE STAGE Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Egg Egg Egg Egg Egg Egg Egg Egg Egg Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac LENGTH 9.7 10.3 5.1 10.0 7.6 5.2 11.5 16.7 7.1 9.2 10.0 12.4 17.2 6.1 5.3 1.3 1.4 1.4 1.3 1.4 1.0 1.4 1.3 1.4 1.5 6.2 6.1 5.9 6.3 6.0 6.4 4.9 5.2 6.2 6.3 5.4 6.2 5.6 6.2 5.1 5.5 5.7 5.3 5.9 7.8 7.0 5.5 5.3 6.2 6.1 5.8 5.9 6.4 7.1 6.4 6.3 5.7 5.3 5.2 5.1 5.2 5.1 5.9 3.0 2.6 2.5 2.4 2.8 2.6 PLUS COUNT D-43

APPENDIX D (coot.)

CYPRINIDAE sp.

Yolk-sac 1.8 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 1.3 ICTIOBINAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 6.8 ICTIOBINAE sp.

Yolk-sac 7.5 PUMPKINSEED type Post Yolk-sac 8.4 PUMPKINSEED type Post Yolk-sac 8.1 PUMPKINSEED type Yolk-sac 5.2 Sander sp.

Yolk-sac 5.1 DARTER sp.

Post Yolk-sac 12.2 DARTER sp.

Post Yolk-sac 7.8 DARTER sp.

Post Yolk-sac 6.9 DARTER sp.

Post Yolk-sac 8.2 DARTER sp.

Yolk-sac 5.7 DARTER sp.

Post Yolk-sac 7.0 FRESHWATER DRUM Post Yolk-sac 10.1 FRESHWATER DRUM Post Yolk-sac 15.8 SAMPLE DATE: 17 June START DATE and TIME:

17JUN14:21:04 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Night DEPTH: HOT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.013972 STUDY GRAB TE!MPERATURE (F):

77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.4 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD:

15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gala x 10^6):

604.8 TAXA Dorosoma sp.

Dorosoma sp.

Dorosomsa sp.

COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP Pimephales type Pimsephales type Pimephales type Pinmephales type Pimephales type Pitnephales type Pimephales type Pimephales type Pimephales type Pimephale s type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pirnephales type Piniephales type Pimephales type Pimephales type Pimephales type Pimephales type CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE ap.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDRE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

Moxostomsa sp.

Moxostomna sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

ICTIOBINAE sp.

DARTER sp.

DARTER sp.

DARTER sp.

FRESHWATER DRUM ROUND GOBY LIFE STAGE Post Yolk-sac Post Yolk-sac Post Yolk-sac Egg Egg Egg Egg Egg Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Post Yolk-sac Egg Juvenile LENGTH 6.3 8.4 12.7 1.4 1.2 1.4 1.0 1.3 5.1 4.9 5.7 5.7 5.9 5.6 6.2 5.7 6.2 5.8 5.7 4.9 5.8 6.0 5.7 6.2 5.0 6.1 4.9 4.8 6.7 4.9 4.4 6.4 6.8 5.8 6.3 4.9 5.1 6.2 6.1 6.2 6.5 5.7 5.4 6.0 2.6 2.4 1.4 13.3 12.7 7.0 7.1 6.8 7.6 8.1 15.1 14.0 1.3 7.7 PLUS COUNT 30 D-44

APPENDIX D (cant.)

ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.3 ROUND GORY Juvenile 6.7 SAMPLE DATE:

17 June START DATE and TIME:

l7JUNl4:21:04 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH: ROT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.014803 STUDY GRAB TEMPERATURE (F):

77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.4 FORERAY CURRENT VELOCITY (ft/see):

1.50 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 10.9 Dorosoma ap.

Post Yolk-sac 10.6 Dorosoma sp.

Post Yolk-sac 10.2 Dorosoma sp.

Post Yolk-sac 7.3 COMMON CARP Egg

1. 5 COMHON CARP Egg 1.5 COMHON CARP Egg
1. 4 COMHON CARP Egg 1.2 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sec 5.8 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 4.9 Pimephales type Yolk-sac 5.5 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 4.9 Pimephales type Yolk-sac 4.5 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 15 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 5.8 CYPRINIDAE sp.

Yolk-sac 6.1 CYPRINIDAX sp.

Yolk-sac 6.3 CYPRIHIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 5.1 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 2.3 CYPRINIDAE sp.

Yolk-sac 2.8 CYPRINIDAE sp.

Yolk-sac 1.4 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 2.2 CYPRINIDAE sp.

Yolk-sac 2.6 CYPRINIDAE sp.

Yolk-sac 2.9 CYPRINIDAE sp.

Yolk-sac 2.5 CYPRINIDAR sp.

Yolk-sac 2.9 Moxostoma sp.

Post Yolk-sac 12.7 Moxostoma sp.

Post Yolk-sac 15.2 ICTIORINAE sp.

Yolk-sac 7.7 GREEN SUNFISH Juvenile 15.2 PUNPKINSEED type Yolk-sac 5.1 PUMPKINSEED type Yolk-sac 5.2 DARTER sp.

Yolk-sac 8.3 DARTER sp.

Post Yolk-sac 15.1 DARTER sp.

Post Yolk-sac 9.9 FRESHWATER DRUM Yolk-sac 6.6 ROUND GORY Juvenile 7.4 ROUND GORY Juvenile 7.6 ROUND GORY Juvenile 7.6 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 8.1 ROUND GORY Juvenile 7.1 ROUND GORY Juvenile 7.3 ROUND GORY Juvenile 7.0 D-45

APPENDIX D (cant.)

SAMPLE DATE: 24 June START DATE and TIME: 24CJUNl4:18:29 SAMPLE DURATION (minutes): 36.00 DIEL PERIOD: Day DEPTH:

SUE REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.013515 STUDY GRAB TEMPERATURE (F):

77.5 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.2 FOREBAY CUREN VELOCITY (ft/sea):

1.30 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

777.6 LIFE PLUS TAASTAGE LENGTH COUNT Dorosoma ap.

Post Yolk-sac 12.8 Dorosomsa sp.

Post Yolk-sac 13.4 Dorosoma sp.

Post Yolk-sac 10.6 Dorosomsa ap.

Post Yolk-sac 13.8 Dorosoma sp.

Post Yolk-sac 11.2 Dorosoma sp.

Post Yolk-sac 12.2 Dorosoma sp.

Post Yolk-sac 9.8 Dorosoxna sp.

Post Yolk-sac 7.5 Dorosoma sp.

Yolk-sac 3.7 COMMON CARP Yolk-sac 6.1 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 6.4 COMMON CARP Yolk-sac 6.7 Pimephales type Yolk-sac 5.7 Pismephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 7.6 CYPRINIDAE sp.

Yolk-sac 5.1 CYPRINIDAE sp.

Yolk-sac 4.9 CYPRINIDAE sp.

Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 4.2 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 5.3 PUMPKINSEED type Yolk-sac 5.5 PUNPKINSEED type Yolk-sac 5.4 DARTER sp.

Yolk-sac 6.0 DARTER sp.

Yolk-sac 6.7 FRESHWATER DRUM Post Yolk-sac 4.9 FRESHWATER DRUM Egg 1.3 UNIDENTIFIED Yolk-sac 3.1 SAMPLE DATE:

24 June START DATE and TIME: 24JUN14:I8:29 SAMPLE DURATION (minutes): 27.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.014211 STUDY GRAB TEMPERATURE (F) :

77.5 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.2 FOREBAY CURRENT VELOCITY (ft/sec) 1.30 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 5.4 Dorosoma sp.

Post Yolk-sac 10.4 Dorosomsa sp.

Post Yolk-sac 9.7 COMMON CARP Yolk-sac 7.1 COMMON CARP Yolk-sac 7.1 COMMON CARP Yolk-sac 5.3 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 5.5 COMMON CARP Egg 1.4 COMMON CARP Egg 1.2 Hypophthalmichthys type Egg 3.2 Hypophthalmichthys type Egg 3.7 Nypophthalmsichthys type Egg 2.1 Hypophthalmichthys type Egg 3.8 Hypopbthalmichthys type Egg 3.8' Nypophthalmsichthys type Egg 3.4 Hypophthalmichthys type Egg 3.6 Hypophthalmichthys type Egg 2.8 Hypophthalmichthys type Egg 2.9 Pimsephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.5 Pimephales type Yolk-sac 5.7 Pimsephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.6 Pimsephales type Yolk-sac 6.2 Pimephales type Yolk-sac 5.7 Pimsephales type Yolk-sac 6.2 D-46

APPENDIX D (cont.)

Pimsepbales type Yolk-sac 6.0 Pimsepbales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.5 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.5 Pimephales type Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 5.0 CYPRINIDAE sp.

Yolk-sac 5.9 CYPRINIDAX sp.

Yolk-sac 5.3 PUMPEINSEED type Yolk-sac 5.7 DARTER sp.

Post Yolk-sac 10.2 FRESHWATER DRUM Egg 1.3 SAMPLE DATE:

24 June START DATE and TIME: 24JUN14:I9:I7 SAMPLE DURATION (minutes) : 10.00 DIEL PERIOD: Day DEPTH:

HOT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.013968 STUDY GRAB TEMPERATURE (F):

77.2 STUDY GRAB DISSOLVED OXYGEN (rag/L) :

8.2 FOREBAY CURRENT VELOCITY (ft/sec) 1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 11.3 Dorosoma sp.

Post Yolk-sac 16.1 COMMON CARP Yolk-sac 5.6 Hypophthalmichthys type Egg 4.3 Hypophthalmsichthys type Egg

4. 6 Hypophthalmichthys type Egg 3.8 Hypophthalmichthys type Egg 3.1 Pimsephales type Yolk-sac 6.3 Pixsephales type Yolk-sac 6.2 Pizsephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 6.8 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 5.3 BLACESTRIPE TOPMINNOW Yolk-sac 6.1 DARTER sp.

Yolk-sac 6.9 SAMPLE DATE: 24 June START DATE and TIME: 24JUN14:I9:I7 SAMPLE DURATION (minutes) :

10.00 DIEL PERIOD: Day DEPTH: HOT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.013368 STUDY GRAB TEMPERATURE (F):

77.2 STUDY GRAB DISSOLVED OXYGEN (magfL):

8.2 FORERAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

777.6 LIFE PLUS TmX STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 10.0 Dorosoma sp.

Post Yolk-sac 7.2 Dorosoma sp.

Post Yolk-sac 9.6 Dorosoma sp.

Post Yolk-sac 10.1 COMMON CARP Yolk-sac 5.9 Mypophthalmichthys type Egg 4.5 Hypophthalmichthys type Egg 3.2 Hypophthalmsichthys type Egg 4.1 Hypophthalmsichthys type Egg 4.2 Nypophthalmichthys type Egg 4.7 Hypophthalmichthys type Egg 4.3 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.4 DARTER sp.

Yolk-sac 6.9 FRESHWATER DRUM Egg

1. 8 SAMPLE DATE: 24 June START DATE and TIME:

24JUNI4:21:41 SAMPLE DURATION (minutes): 21.00 DIEL PERIOD: Night DEPTH:

SUN REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.013720 STUDY GRAB TEMPERATURE (F) :

76.6 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

6.8 FOREBAY CURRENT VELOCITY (ft/sec) :

1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6) :

777.6 LIFE PLUS TmX STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 12.1 Dorosoma sp.

Post Yolk-sac 7.4 Dorosomsa sp.

Post Yolk-sac 10.0 Dorosoma sp.

Post Yolk-sac 11.2 Dorosoma sp.

-Post Yolk-sac 12.8 Dorosoma sp.

Post Yolk-sac 9.2 Dorosomsa sp.

Post Yolk-sac 8.7 Dorosoisa sp.

Post Yolk-sac 12.5 Dorososi sp.

Post Yolk-sac 13.7 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 6.1 D-47

APPENDIX D (cant.)

COMMON CARP Yolk-sac 7.4 COMMON CARP Yolk-sac 5.8 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 7.9 COMMON CARP Yolk-sac 8.2 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 5.9 COMMON CARP Egg I. 4 COMMON CARP Egg

1. 5 COMMON CARP Egg
1. 3 Hypophthalzsichthys type Egg.

Mypophthalmichthys type Egg 4.0 BLUNTNOSE MINNOW Juvenile 17.9 Pimephales type Yolk-sac 4.7 Pimephales type Yolk-sac 5.6 Pixnephales type Yolk-sac 5.7 Pimnephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.1 Pimnephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 37 CYPRINIDAE ap.

Yolk-sac 5.3 CYPRINIDAE ap.

Yolk-sac 6.2 CYPRINIDAE ap.

Yolk-sac 5.1 CYPRIMIDAE sp.

Yolk-sac 6.6 CYPRINIDAE ap.

Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 5.4 CYPRINIDAE ap.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRIMIDAE ap.

Yolk-sac 5.0 CYPRIMIDAE sp.

Yolk-sac 6.0 CYPRIMIDAE sp.

Yolk-sac 6.2 CYPRINIDAE ap.

Yolk-sac 6.7 CYPRINIDAE ap.

Yolk-sac 6.2 CYPRIMIDAE sp.

Yolk-sac 5.8 CYPRIMIDAE sp.

Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 5.4 CYPRINIDAE ap.

Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 5.4 ICTIOBINAE ap.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOBINRE sp.

Yolk-sac 6.1 ICTIOBIMAE sp.

Yolk-sac 7.2 ICTIOBINAE sp.

Yolk-sac 6.7 ICTIOBINAE sp.

Yolk-sac 6.1 BLACKSTRIPE TOPMINNOW Juvenile 10.2 PUMPKINSEED type Post Yolk-sac 10.0 PUMPKINSEED type Yolk-sac 6.0 PUMPKINSEED type Yolk-sac 3.7 LOGPERCH type Yolk-sac 5.7 DARTER sp.

Yolk-sac 8.0 FRESHWATER DRUM Post Yolk-sac 10.4 FRESHWATER DRUM Post Yolk-sac 6.6 FRESHWATER DRUM Post Yolk-sac 7.6 FRESHWATER DRUM Post Yolk-sac 8.7 FRESHWATER DRUM Post Yolk-sac 9.7 FRESHWATER DRUM Post Yolk-sac 6.7 ROUND GOBY Juvenile 6.8 D-48

APPENDIX D (cont.)

SAMPLE DATE: 24 June START DATE DIEL PERIOD: Night DEPTH: SUR STUDY GRAB TEMPERATURE (F):

76.6 STUDY GRAB EXTRAPOLATION PERIOD: 22-30 June REPLICATE:S DISSLVEDOXYEN (g/L)U6.

SAMPLE DURATION (minutes): 21.00 VOLUME SAMPLED (gals x 10A6):

0.023002 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 FOR EXTRAPOLATION PERIOD (gals xt 10A6):

777.6 TAfA GIZZARD SHAD GIZZARD SHAD GIZZARD SHAD Dorosoma sp.

Dorosoma sp.

Dorosomsa sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

Dorosoma sp.

COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COM*MON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP C OMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP Hypophthalmicbthys type Hypopbthalmichtbys type Hypophtbalmichthys type Hypophthalmsichthys type Hypophthalmichthys type BLURTNOSE MINNOW Pimephales type Pimnephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pimephales type Pixmephales type Pixsephsles type Pimephales type Pimephales type Pimiephales type Pimesphales type Pimephale s type Pixsephale s type Pimuephales type CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRINIDAE sp.

CYPRIHIDAE sp.

ICT IOBINAE sp.

BROOK SILVERSIDE PUMPKINSEED type PUMPEINSEED type Lepomis sp.

Lepomis sp.

Lepomis sp.

LOGPERCH type DARTER sp.

DARTER sp.

DARTER sp.

LIFE STAGE Juvenile Juvenile Juvenile Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Egg Egg Egg Egg Egg Egg Egg Egg Juvenile Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Yolk-sac Juvenile Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac Post Yolk-sac Post Yolk-sac Yolk-sac Yolk-sac Yolk-sac Post Yolk-sac LERGTH 21.2 21.0 18.7 15.2 6.8 8.7 8.2 8.0 10.0 6.5 10.1 5.7 6.5 6.7 6.2 6.5 5.9 7.2 6.5 7.5 6.0 6.2 7.1 5.8 6.5 7.2 7.2 6.4 5.8 7.4 1.0 1.4 1.5 1.4 4.4 3.9 4.4 4.8 3.9 24.1 5.2 4.8 6.1 5.1 5.6 5.8 6.0 5.1 5.5 6.0 5.1 5.0 5.7 5.1 5.6 4.8 5.7 6.0 5.9 6.2 5.6 6.1 5.8 5.4 6.2 5.9 5.5 19.8 5.2 5.2 4.9 9.0 15.6 10.2 6.2 6.5 6.2 11.2 PLUS COUNT 7

D-49

APPENDIX D (cant.)

FRESHWATER DRUM Post Yolk-sac 6.1 FRESHWATER DRUM Post Yolk-sac 8.0 ROUND GORY Juvenile 7.3 ROUND GORY Juvenile 7.8 ROUND GORY Juvenile 9.0 ROUND GORY Juvenile 7.7 ROUND GORY Juvenile 7.7 ROUND GORY Juvenile 7.5 SAMPLE DATE:

24 June START DATE and TIME: 24JUNI4:22:17 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Night DEPTH: ROT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.015147 STUDY GRAB TEMPERATURE (F):

76.6 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

6.8 FORERAY CURRENT VELOCITY (ft/sec) 1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

777.6 LIFE PLUS TAASTAGE LENGTH COUNT Dorosomsa sp.

Post Yolk-sac 13.4 Dorosoma sp.

Post Yolk-sac 14.7 COMMON CARP Yolk-sac 6.8 COMMON CARP Yolk-sac 5.5 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 6.0 COMMON CARP Yolk-sac 7.1 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.4 Hypophthalmichthys type Egg 4.8 Pimephales type Yolk-sac 5.2 Pimnephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 6.1 Pinmephales type Yolk-sac 5.9 Pimephales type Yolk-sac 4.8 Pimsephales type Yolk-sac 5.7 Pimephales type Yolk-sac 4.9 CYPRINIDAE sp.

Yolk-sac 5.9 CYPRINIDAR sp.

Yolk-sac 7.0 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 5.5 CYPRINIDAE sp.

Yolk-sac 6.1 CYPRINIDAE sp.

Yolk-sac 7.0 CYPRINIDAE sp.

Yolk-sac 5.6 ICTIORINAE sp.

Juvenile 24.5 RROOK SILVERSIDE Yolk-sac 5.6 LARGEMOUTH BASS Juvenile 35.5 LOGPERCH type Yolk-sac 5.5 DARTER sp.

Yolk-sac 7.0 DARTER sp.

Yolk-sac 8.4 DARTER sp.

Juvenile 13.1 DARTER sp.

Juvenile 13.7 DARTER sp.

Post Yolk-sac 10.3 FRESHWATER DRUM Post Yolk-sac 7.7 FRESHWATER DRUM Post Yolk-sac 7.9 FRESHWATER DRUM Post Yolk-sac 11.3 ROUND GORY Juvenile 8.0 ROUND GORY Juvenile 14.5 ROUND GORY Juvenile 15.5 SAMPLE DATE: 24 June START DATE and TIME: 24JUNI4:22:17 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: ROT REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.014204 STUDY GRAB TEMPERATURE (F):

76.6 STUDY GRAB DISSOLVED OXYGEN (mg/L):

6.8 FORERAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 9.6 Dorosoma sp.

Post Yolk-sac 10.4 Dorosoma sp.

Post Yolk-sac 14.3 COMMON CARP Yolk-sac 6.5 COMMON CARP Yolk-sac 6.3 COMMON CARP Yolk-sac 5.3 COMMON CARP Yolk-sac 5.7 COMMON CARP Yolk-sac 6.4 COMMON CARP Yolk-sac 7.2 COMMON CARP Yolk-sac 7.6 COMMON CARP Yolk-sac 6.1 Hypophthalmichthys type Egg 4.8 Hypophthalmichthys type Egg 4.2 Hypophtbalmichthys type Egg.

Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.0 Pixsephales type Yolk-sac 5.5 Pimephales type Yolk-sac 4.4 Pimephales type Yolk-sac 4.7 D-50

APPENDIX D (cant.)

Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.1 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 5.4 ICTIOBINAE sp.

Post Yolk-sac 13.4 PUMPEINSEED type Yolk-sac 5.5 PUMPKINSEED type Yolk-sac 4.8 LOGPERCH type Yolk-sac 6.0 DARTER sp.

Post Yolk-sac 13.0 FRESHWATER DRUM Juvenile 26.1 FRESHWATER DRUM Post Yolk-sac 13.2 FRESHWATER DRUM Post Yolk-sac 5.2 ROUHD GOBY Juvenile 7.6 ROUND GORY Juvenile 13.0 SAMPLE DATE:

9 July START DATE and TIME: 09JULI4:I8:08 SAMPLE DURATION (minutes): 22.00 DIEL PERIOD:

Day DEPTH:

SUN REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.013343 STUDY GRAB TEMPERATURE (F):

80.1 STUDY GRAB DISSOLVED OXYGEN (mng/L):

9.0 FORERAY CURRENT VELOCITY (ft/sac):

1.10 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT Lepomis sp.

Post Yolk-sac 7.6 LOGPERCN type Yolk-sac 6.2 DARTER sp.

Yolk-sac 8.6 SAMPLE DATE:

9 July START DATE and TIME: O9JULl4:18:08 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD:

Day DEPTH:

SUN REPLICATE: B VOLUME SAMPLED (gals x 10^6):

0.015999 STUDY GRAB TEMPERATURE (F):

80.1 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.0 FOREBAY CURRENT VELOCITY (ft/sec):

1.10 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x i0A6):

1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT GIZEARD SHAD Juvenile 36.0 Hypophthalmichthys type Egg 3.2 SAMPLE DATE:

9 July START DATE and TIME:

O9JUL14:18:40 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD:

Day DEPTH: SOT REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.014534 STUDY GRAS TEMPERATURE (F):

80.1 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.9 FOREBAY CURRENT VELOCITY (ft/sac):

1.40 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

1036.8 LIFE PLUS TAKA STAGE LENGTH COUNT COMMON CARP Egg 1.4 Hypophthalmichthys type Egg 2.8 Hypophthalsmichthys type Egg 2.6 SAMPLE DATE:

9 July START DATE and TIME:

O9JULl4:I8:40 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: SOT REPLICATE: S VOLUME SAMPLED (gals x 10^6):

0.015402 STUDY GRAB TEMPERATURE (F):

80.1 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.9 FORESAY CURRENT VELOCITY (ft/sec):

1.40 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

1036.8 LIFE PLUS TAKA STAGE LENGTH COUNT COMMON CARP Egg 1.3 Nypophthalmichthys type Egg 3.0 Pimephales type Yolk-sac 5.6 ICTIOBINAE sp.

Yolk-sac 6.0 SAMPLE DATE:

9 July START DATE and TIME:

O9JULI4:21:31 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Might DEPTH: SUN REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.018442 STUDY GRAB TEMPERATURE (F) :

79.0 STUDY GRAB DISSOLVED OXYGEN (xsg/L):

8.1 FOREBAY CURRENT VELOCITY (ft/sec):

0.90 EXYRAPOLATION PERIOD:

1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x i0A6):

1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT GARA sp.

Post Yolk-sac 25.2 GAR sp.

Post Yolk-sac 26.1 Dorosoma sp.

Post Yolk-sac 17.1 Dorosoma sp.

Post Yolk-sac 8.5 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.3 Pimsephales type Yolk-sac 5.0 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.0 Pisiephales type Yolk-sac 5.6 Pimephales type Yolk-sac 6.0 D-5 1

APPENDIX D (cont.)

Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 4.9 Pimnephales type Yolk-sac 5.4 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.0 Pimsephales type Post Yolk-sac 6.0 Pimsephales type Post Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 4.7 CYPRINIDAK sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 5.1 CYPRINIDAE sp.

Yolk-sac 5.1 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRIHIDAE sp.

Yolk-sac 6.2 ICTIORINAE sp.

Yolk-sac 6.2 ICTIORINAS sp.

Yolk-sac 6.7 PUMPRINSEED type Post Yolk-sac 8.1 PUMPKINSEED type Post Yolk-sac 7.2 FRESHWATER DRUM Egg 1.2 ROUND GORY Juvenile 6.9 ROUND GORY Juvenile 7.3 ROUND GORY Juvenile 6.7 ROUND GOBY Juvenile 6.8 ROUND GORY Juvenile 6.7 ROUND GORY Juvenile 7.0 ROUND GORY Juvenile 6.9 ROUND GORY Juvenile 7.0 ROUND GORY Juvenile 6.8 SAMPLE DATE:

9 July START DATE and TIME: O9JUL14:21:31 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Night DEPTH: SUE REPLICATE: B VOLUME SAMPLED (gals x 10^6):

0.017087 STUDY GRAB TEMPERATURE (F) :

79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

8.1 FORERAY CURRENT VELOCITY (ft/sec) 0.90 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

1036.8 LIFE PLUS TAm STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 12.2 Pimephales type Yolk-sac 6.0 Pizsephales type Yolk-sac 6.4 Pimsephales type Yolk-sac 6.4 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRIHIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRIHIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.7 CHARNEL CATFISH Juvenile 18.0 CNHANEL CATFISH Juvenile 17.6 CHANNEL CATFISH Juvenile 16.0 FRESHWATER DRUM Egg 1.5 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.4 ROUND GORY Juvenile 7.6 ROUND GORY Juvenile 7.2 SAMPLE DATE:

9 July START DATE and TIME: O9JULI4:21:55 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH:

ROT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.014709 STUDY GRAB TEMPERATURE (F):

79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L):

8.0 FORERAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD:

1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

1036.8 LIFE PLUS TmX STAGE LENGTH COUNT COMMON CARP Egg 1.4 Pimephales type Yolk-sac 6.4 Pimephales type Yolk-sac 6.2 Piisephales type Yolk-sac 5.6 Pimephales type Yolk-sac 6.0 Pimephales type "Yolk-sac 6.0 Pimephales type Yolk-sac 5.4 Pimsephales type Yolk-sac 5.8 CYPRINIDAE sp.

Yolk-sac 6.6 CHANNEL CATFISH Juvenile 17.0 PUMPKINSEED type Juvenile 13.8 PUMPEINSEED type Juvenile 14.7 D-52

APPENDIX D (cant.)

FRESHWATER DRUM Egg 1.6 FRESHWATER DRUM Egg 1.5 ROUND GORY Juvenile 6.9 ROUND GORY Juvenile 7.3 ROUND GORY Juvenile 7.1 ROUND GORY Juvenile 7.8 ROUND GORY Juvenile 7.2 ROUND GORY Juvenile 8.5 ROUND GORY Juvenile 6.9 ROUND GORY Juvenile 7.0 ROUND GORY Juvenile 7.4 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.7 ROUND GORY Juvenile 7.4 SAMPLE DATE: 9 July START DATE and TIME: O9JUL14:21:55 SAMPLE DURATION (minutes) :

11.O00 DIEt PERIOD: Night DEPTH: ROT REPLICATE:

R VOLUME SAMPLED (gals x 10A6):

0.015056 STUDY GRAB TEMPERATURE (F) :

79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

8.0 FOREBAY CURRENT VELOCITY (ft/sea) :

1.50 EXTRAPOLATION PERIOD:

1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

1036.8 LIFE PLUS TARA STAGE LENGTH COUNT CONH0N CARP Yolk-sac 5.8 Pimephales type Yolk-sac 5.5 ICTIORINAE sp.

Yolk-sac 6.8 FRESHWATER DRUM Yolk-sac 4.9 ROUND GORY Juvenile 7.2 ROUND GORY Juvenile 7.5 ROUND GORY Juvenile 7.2 SAMPLE DATE: 15 July START DATE and TIME: 15JULl4:18:03 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE: A VOLUME SAMPLED (gals x i0A6):

0.013773 STUDY GRAB TEMPERATURE (F):

75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

7.6 FORERAY CURRENT VELOCITY (ft/sec):

1. 60 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 1^6) 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT CONHON CARP Egg 1.4 COMMON CARP Egg 1.1 COMMON CARP Egg 1.4 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 5.1 CYPRINIDAE sp.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 6.2 CATOSTOMIDAE sp.

Yolk-sac 4.8 SAMPLE DATE: 15 July START DATE and TIME: 1SJUL14:I8:03 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH:

SUN REPLICATE:

N VOLUME SAMPLED (gals x i0A6):

0.013440 STUDY GRAB TEMPERATURE (F):

75.2 STUDY GRAB DISSOLVED OXYGEN (rag/L):

7.6 FORERAY CURRENT VELOCITY (ft/sec) 1.60 EXTRAPOLATION PERIOD:

13-19 July HAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT COHHON CARS Egg

1. 2 Pimephales type Yolk-sac 4.9 CYPRINIOAE sp.

Yolk-sac 5.6 Lepomis sp.

Yolk-sac 5.5 FRESHWATER DRUM Egg 1.2 SAMPLE DATE:

15 July START DATE and TIME: 15JULI4:18:30 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH: ROT REPLICATE:, A VOLUME SAMPLED (gals x 10A6):

0.014907 STUDY GRAB TEMPERATURE (F):

75.0 STUDY GRAB DISSOLVED OXYGEN (mag/L) :

7.6 FORERAY CURRENT VELOCITY (ft/sea) :

1. 60 EXTRAPOLATION PERIOD: 13-19 July HAREUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma ap.

Post Yolk-sac 9.3 Dorosoma sp.

Post Yolk-sac 7.8 COMMON CARP Egg

1. 5 COMMON CARP Egg
1. 5 COMMON CARP Egg
1. 4 Pimephales type Yolk-sac 6.5 Pimephales type Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 4.7 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIOAE sp.

Yolk-sac 5.2 FRESHWATER DRUM Yolk-sac 5.4 FRESHWATER DRUM Egg 1.S FRESHWATER DRUM Egg 1.S D-53

APPENDIX D (cant.)

SAMPLE DATE:

15 July START DATE and TIME: 15JULl4:lS:30 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD:

Day DEPTH:

HOT REPLICATE: B VOLUME SAMPLED (gals x l0^6):

0.016430 STUDY GRAB TEMPERATURE (F):

75.0 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.6 FOREBAY CURRENT VELOCITY (ft/sea):

1.60 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x l0^6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.4 COMMON CARP Egg 1.3 COMMON CARP Egg 1.4 COMMON CARP Egg 1.5 COMMON CARP Egg 1.4 COMMON CARP Egg 1.3 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.3 Pimnephales type Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE ap.

Yolk-sac 4.9 CYPRINIDAE sp.

Yolk-sac 4.7 FRESHWATER DRUM Yolk-sac 5.4 SAM4PLE DATE: 15 July START DATE and TINE: 15JULI4:21:37 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD:

Might DEPTH: SUR REPLICATE:

A VOLUME SAMPLED (gals x lots):

0.014132 STUDY GRAB TEMPERATURE (F):

74.5 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.3 FOREBAY CURRENT VELOCITY (ft/sea):

1.40 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x l0^6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT GIZZARD SHAD Juvenile 24.1 Dorosoma sp.

Post Yolk-sac 10.3 COMMON CARP Yolk-sac 6.2 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 7.0 COMMON CARP Yolk-sac 6.6 COMMON CARP Egg 1.5 Pismephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 4.8 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.7 Pimnephales type Yolk-sac 4.8 Pimephales type Yolk-sac 4.8 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 6.0 Pimaephales type Yolk-sac 6.2 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 18 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 5.1 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.1 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 5.1 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 5.4 CHANNEL CATFISH Juvenile 16.0 RANDED RILLIFISH Juvenile 17.5 PUMPKINSEED type Yolk-sac 5.8 PUMPEINSEED type Yolk-sac 5.8 PUMPKINSEED type Yolk-sac 4.8 PUMPKINSEED type Yolk-sac 6.0 Lepomis ap.

Post Yolk-sac 10.7 Lepomis sp.

Post Yolk-sac 8.8 Lepomis sp.

Juvenile 15.0 Leporsis ap.

Juvenile 15.3 Lepomis sp.

Juvenile 16.2 Lepomis sp.

Juvenile 16.4 ROUND GOBY Juvenile 6.7 0-54

APPENDIX D (cant.)

SAMPLE DATE: 15 July START DATE and TIME:

l5JULl4:21:37 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Night DEPTH:

StUR REPLICATE:

B VOLUME SAMPLED (gals x lO^6):

0.013992 STUDY GRAB TEMPERATURE (F):

74.5 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.3 FOHEBAY CURRENT VELOCITY (ft/sec):

1.40 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gala x 10^6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 9.7 COMMON CARP Yolk-sac 7.3 COMMON CARP Juvenile 29.0 COMMON CARP Egg 1.7 Pimephales type Yolk-sac 5.6 Pimsephales type Yolk-sac 5.4 Pimephales type Yolk-sac 4.9 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.5 Pimephales type Yolk-sac 4.4 Pimephales type Yolk-sac 4.8 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 6.5 Pimephales type Yolk-sac 5.3 Pismephales type Yolk-sac 5.4 Pimsephales type Yolk-sac 5.5 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.5 Pimephales type Yolk-sac 4.8 Pimephales type Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 5.8 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 6.0 CHANNEL CATFISH Juvenile 16.9 CMANNEL CATFISM Juvenile 18.7 CHANNEL CATFISH Juvenile 15.4 CHARNEL CATFISH Juvenile 16.8 Lepomis sp.

Juvenile 10.4 Lepomis sp.

Juvenile 13.2 Lepomis sp.

Juvenile 14.0 Lepomis sp.

Juvenile 14.2 Lepomis sp.

Juvenile 13.9 DARTER sp.

Post Yolk-sac 10.3 ROUND GOBY Juvenile 7.8 ROUND GOBY Juvenile 7.6 SAMPLE DATE:

15 July START DATE and TIME: 15JULI4:22:II SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.016009 STUDY GRAB TEMPERATURE (F):

74.3 STUDY GRAB DISSOLVED OXYGEN (zsg/L):

7.3 FOREBAY CURRENT VELOCITY (ft/sec):

1.40 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 8.2 COMMO4N CARP Egg 1.1 COMMON CARP Egg 1.1 Pimephales type Yolk-sac 4.8 Pisephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 4.7 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac.

Pimephales type Yolk-sac.

3 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 6.1 CYPRINIDAS sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 6.0 0-55

APPENDIX D (cant.)

CYPRINIDAE sp.

Yolk-sac 5.9 CYPRINIDAE sp.

Yolk-sac 6.2 CHANNEL CATFISH Juvenile 15.6 CHANNEL CATFISH Juvenile 16.1 PUMPEINSEED type Yolk-sac 4.6 PUMPKINSEED type Yolk-sac 5.4 PUMPEINSEED type Yolk-sac 5.2 PUNPKINSEED type Yolk-sac 5.1 Lepomis sp.

Juvenile 14.1 Lepomis sp.

Juvenile 11.2 SAMPLE DATE:

15 July START DATE and TINE: 15JULI4:22:II SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH:

NOT REPLICATE: B VOLUME SAMPLED (gals x 10A6):

0.017717 STUDY GRAB TEMPERATURE (F):

74.3 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.3 FOREBAY CURRENT VELOCITY (ft/sec):

1.40 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 8.9 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 7.2 CHANNEL CATFISH Juvenile 10.2 CHANNEL CATFISH Juvenile 10.4 CHANNEL CATFISH Juvenile 10.6 CHANNEL CATFISH Juvenile 12.7 CHANNEL CATFISM Juvenile 10.6 PUMPKINSEED type Yolk-sac 5.6 PUMPEINSEED type Yolk-sac 4.7 Lepomis sp.

Juvenile 9.6 Lepomis sp.

Juvenile 10.6 Lepomis sp.

Juvenile 11.0 Lepomis sp.

Juvenile 10.0 Lepomsis sp.

Juvenile 15.5 Lepomsis sp.

Juvenile 14.8 Lepomis sp.

Juvenile 16.2 Lepomis sp.

Juvenile 18.3 LOGPERCH type Yolk-sac 6.2 LOGPERCH type Yolk-sac 6.3 LOGPERCH type Yolk-sac 5.6 FRESHWATER DRUM Egg 1.5 FRESHWATER DRUM Egg 1.6 SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:18:11 SAMPLE DURATION (minutes):

11.00 DIEL PERIOD:

Day DEPTH:

SUIR REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.014226 STUDY GRAB TEMPERATURE (F):

83.3 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.5 FORERAY CURRENT VELOCITY (ft/sec):

1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals a lOA6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT Pimephales type Yolk-sac 4.8 FRESHWATER DRUM Yolk-sac 4.2 FRESHWATER DRUM Yolk-sac 3.2 FRESHWATER DRUM Yolk-sac 4.2 UNIDENTIFIED Yolk-sac 2.7 UNIDENTIFIED Yolk-sac 2.9 SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:18:11 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTM:

SUN REPLICATE: B VOLUME SAMPLED (gals a 10A6):

0.015016 STUDY GRAB TEMPERATURE (F):

83.3 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.5 FOREBAY CURRENT VELOCITY (ft/sec):

1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT Pimephales type Yolk-sac 3.8 UNIDENTIFIED Egg 1.2 SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:I8:34 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: BUT REPLICATE: A VOLUME SAMPLED (gals a 10A6):

0.013453 STUDY GRAB TEMPERATURE (F):

82.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.4 FOREBAY CURRENT VELOCITY (ft/sec):

1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 6.6 D-56

APPENDIX D (cont.)

FRESHWATER DRUM Yolk-sac 3.8 UNIDENTIFIED Egg

1. 3 UNIDENTIFIED Egg 1.4 UNIDENTIFIED Egg
1. 4 SAMPLE DATE: 22 July START DATE and TIME:

22JULl4:18:34 SAMPLE DURATION (minutes) : 11.00 DIEL PERIOD: Day DEPTH: ROT REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.014740 STUDY GRAB TEMPERATURE (F) :

82.9 STUDY GRAB DISSOLVED OXYGEN (mg/L) : 10.4 FOREBAY CURRENT VELOCITY (ft/see) :

1.60 EXTRAPOLATION PERIOD:

20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 106) 604.8 LIFE PLUS TARA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.0 SAMPLE DATE: 22 July START DATE and TIME: 22JU1I4:21:23 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.015126 STUDY GRAB TEMPERATURE (F):

82.6 STUDY GRAB DISSOLVED OXYGEN (rag/L):

9.4 FORERAY CURRENT VELOCITY (ft/see):

i. 60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 6.3 Pimsephales type Yolk-sac 5.0 Pimsephales type Yolk-sac 5.1 Pimephales type Yolk-sac 5.4 Pimsephales type Yolk-sac 6.0 Pimephales type Yolk-sac 6.3 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 6.2 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAE sp.

Yolk-sac 5.7 CYPRINIDAE sp.

Yolk-sac 5.0 FRESHWATER DRUM Yolk-sac 3.6 SAMPLE DATE: 22 July START DATE and TIME: 22JULI4:21:23 SAMPLE DURATION (minutes) : 11.00 DIEL PERIOD:

Night DEPTH:

SUN REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.015126 STUDY GRAB TEMPERATURE (F):

82.6 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

9.4 FOREBAY CURRENT VELOCITY (ft/sac)

1. 60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.5 Pimephales type Yolk-sac 6.4 CYPRINIDAE ap.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 6.5 FRESHWATER DRUM Yolk-sac 3.1 SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:21:53 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH:

NOT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.014890 STUDY GRAB TEMPERATURE (F):

82.4 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

9.1 FOREBAY CURRENT VELOCITY (ft/see)

1. 60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6) :

604.8 LIFE PLUS TARA STAGE LENGTH COUNT ND ICHTHYOPLANKTON.

0 SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:21:53 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH:

NOT REPLICATE: N VOLUME SAMPLED (gals xt 10A6):

0.013822 STUDY GRAB TEMPERATURE (F):

82.4 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

9.1 FOREBAY CURRENT VELOCITY (ft/see) 1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals it 10^6) :

604.8 LIFE PLUS TARA STAGE LENGTH COUNT Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 4.8 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 6.1 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 6.1 D-57

APPENDIX D (cant.)

SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:18:12 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH:

SUIR REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.018102 STUDY GRAB TEMPERATURE (F):

80.4 STUDY GRAB DISSOLVED OXYGEN (msg/L):

11.0 FOREBAY CURRENT VELOCITY (ft/sec):

1.20 EXTRAPOLATION PERIOD:

27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TARA STAGE LENGTH COUNT CYPRINIDAE sp.

Yolk-sac 5.5 CYPRINIDAE sp.

Yolk-sac 1.9 CYPRINIDAE sp.

Yolk-sac 2.7 FRESHWATER DRUM Yolk-sac 2.5 UNIDENTIFIED Egg 1.2 SAMPLE DATE: 29 July START DATE and TIME: 29JULI4:I8:12 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.014622 STUDY GRAB TEMPERATURE (F):

80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.0 FORERAY CURRENT VELOCITY (ft/sec):

1.20 EXTRAPOLATION PERIOD:

27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg

1. 2 COMMON CARP Egg 1.3 COMMON CARP Egg 1.2 Pimephales type Yolk-sac 4.9 CYPRINIDAE sp.

Yolk-sac 5.3 CYPRINIDAE sp.

Yolk-sac 3.0 ICTIOBINAE sp.

Yolk-sac 8.2 PUMPEINSEED type Yolk-sac 5.2 UNIDENTIFIED Egg 1.2 SAMPLE DATE:

29 July START DATE and TIME: 29JULI4:18:40 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH: ROT REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.016894 STUDY GRAB TEMPERATURE (F):

79.5 STUDY GRAB DISSOLVED OXYGEN (mg/L):

10. 6 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT CYPRINIDAE sp.

Yolk-sac 6.8 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.3 SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:I8:40 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH:

NOT REPLICATE:

B VOLUME SAMPLED (gala x 10^6):

0.016752 STUDY GRAB TEMPERATURE (F):

79.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.6 FORERAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TmX STAGE LENGTH COUNT COMMON CARP Egg 1.4 COMMON CARP Egg 1.3 CYPRINIDAE sp.

Yolk-sac 7.2 SAMPLE DATE: 29 July START DATE and TIME: 29JULI4:21:I5 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH:

SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6):

0.018989 STUDY GRAB TEMPERATURE (F) :

79.0 STUDY GRAB DISSOLVED OXYGEN (mag/L) :

9.6 FOREBAY CURRENT VELOCITY (ft/sea) 1.60 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

604.8 LIFE PLUS TAASTAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 8.2 Pimephales type Yolk-sac 5.2 Pixsephales type Yolk-sac 6.0 Pimoephales type Yolk-sac 6.1 Pimsephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 6.7 Pimsephales type Yolk-sac 4.8 Pimephales type Yolk-sac 5.5 Pimephales type Yolk-sac 5.4 Pimephales type Yolk-sac 4.9 CYPRINIDAE sp.

Yolk-sac 6.8 CYPRIHIDAE sp.

Yolk-sac 5.7 CYPRINIDAE ap.

Yolk-sac 6.3 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.8 CYPRINIDAX sp.

Yolk-sac 7.5 CYPRINIDAE ap.

Yolk-sac 6.1 PUMPEINSEED type Yolk-sac 5.7 D-58

APPENDIX D (cant.)

SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:21:15 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.016178 STUDY GRAB TEMPERATURE (F):

79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.6 FORERAY CURRENT VELOCITY (ft/sec):

1.60 EXTRAPOLATION PERIOD: 21 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

604.8 LIFE PLUS TAXA STAGE LENGTM COUNT Dorosoma sp.

Post Yolk-sac 7.2 COMMON CARP Yolk-sac 7.3 Pimephales type Yolk-sac 5.0 Pimiephales type Yolk-sac 6.1 Pimephales type Yolk-sac 6.2 Pizsephales type Yolk-sac 5.5 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 4.9 Pizsephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.8 CYPRINIDAE sp.

Yolk-sac 6.0 CYPRINIDAE sp.

Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE ap.

Yolk-sac 6.4 PUMPKINSEED type Yolk-sac 5.0 SAMPLE DATE: 29 July START DATE and TIME: 29JULI4:21:41 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: HOT REPLICATE:

A VOLUME SAMPLED (gals x l0^~6):

0.019218 STUDY GRAB TEMPERATURE (F) :

78.8 STUDY GRAB DISSOLVED OXYGEN (rag/L) :

9.4 FOREBAY CURRENT VELOCITY (ft/sec) 1.60 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD *(gals x 1^6) 604.8 LIFE PLUS TAKA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.5 Pimsephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.2 Pimsephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 4.5 Pimephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.4 CYPRINIDAE sp.

Yolk-sac 7.2 CYPRINIDAE sp.

Yolk-sac 6.1 CYPRIMIDAE sp.

Yolk-sac 6.1 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRINIDAE sp.

Yolk-sac 5.0 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.9 SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:21:41 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: HOT REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.018993 STUDY GRAB TEMPERATURE (F):

78.8 STUDY GRAB DISSOLVED OXYGEN (mg/L):

9.4 FOREBAY CURRENT VELOCITY (ft/sec):

1.60 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x I0A6):

604.8 LIFE PLUS TmX STAGE LENGTH COUNT Pimephales type Yolk-sac 5.7 Pimephales type Yolk-sac 5.6 Pimnephales type Yolk-sac 5.4 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 5.7 Pixsephales type Yolk-sac 5.3 Pimephales type Yolk-sac 5.0 Pixmephales type Yolk-sac 6.0 Pimsephales type Yolk-sac 5.1 Pixmephales type Yolk-sac 5.0 Pixsephales type Yolk-sac 6.2 Pimephales type Yolk-sac 5.7 Pixsephales type Yolk-sac 4.9 Pimsephales type Yolk-sac 6.2 CYPRINIDAE sp.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 6.4 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAE sp.

Yolk-sac 6.1 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAE sp.

Yolk-sac 7.1 D-59

APPENDIX D (cont.)

SAMPLE DATE:

12 August START DATE and TIME: 12AUGl4:18:03 SAMPLE DURATION (minutes):

8.00 DIEL PERIOD: Day DEPTH:

SUR REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.014289 STUDY GRAB TEMPERATURE (F):

80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.6 FOREBAY CURRENT VELOCITY (ft/sec):

1.60 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x l0^6) :

1209.6 LIFE PLUS TARA STAGE LENGTH COUNT Mypophthalmichthys type Egg 3.1 UNIDENTIFIED Egg 1.8 SAMPLE DATE:

12 August START DATE and TIME: 12AUG14:18:03 SAMPLE DURATION (minutes):

8.00 DIEL PERIOD: Day DEPTH:

SUE REPLICATE:

B VOLUME SAMPLED (gals x lot6):

0.015501 STUDY GRAB TEMPERATURE (F):

80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.6 FOREBAY CURRENT VELOCITY (ft/sec) 1.60 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10t6):

1209.6 LIFE PLUS TARA STAGE LENGTH COUNT NO ICHTNYOPLANKTON 0

SAMPLE DATE: 12 August START DATE and TIME: 12AUGl4:18:28 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: HOT REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.014557 STUDY GRAB TEMPERATURE (F) :

80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.9 "FOREBAY CURRENT VELOCITY (ft/sec):

1.70 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6):

1209.6 LIFE PLUS TARA STAGE LENGTH COUNT UNIDENTIFIED Yolk-sac 3.2 UNIDENTIFIED Yolk-sac 3.1 SAMPLE DATE:

12 August START DATE and TIME: l2AUG14:18:28 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: ROT REPLICATE:

N VOLUME SAMPLED (gals x 10A6):

0.014343 STUDY GRAB TEMPERATURE (F):

80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.9 FOREBAY CURRENT VELOCITY (ft/sea):

1.70 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x lo^6):

1209.6 LIFE PLUS TARA STAGE LENGTH COUNT NO ICMTHYOPLANKTON 0

SAMPLE DATE: 12 August START DATE and TIME: 12AUG14:21:05 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH:

SUE REPLICATE:

A VOLUME SAMPLED (gals x 10^6):

0.014348 STUDY GRAB TEMPERATURE (F):

80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.3 FOREBAY CURRENT VELOCITY (ft/sec):

1.50 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x I0A6):

1209.6 LIFE PLUS TARA STAGE LENGTH COUNT Pimsephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.7 Pimsephales type Yolk-sac 4.3 Pimiephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.0 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.4 Pimsephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.8 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 6.0 Pimsephales type Yolk-sac 4.8 CYPRINIDAX sp.

Yolk-sac 5.6 CYPRINIDAE sp.

Yolk-sac 7.6 CYPRINIDAK sp.

Yolk-sac 8.1 CYPRINIDAE sp.

Yolk-sac 6.6 CYPRINIDAK sp.

Yolk-sac 5.1 CYPRINIDAK sp.

Yolk-sac 5.7 CYPRINIDAK sp.

Yolk-sac 5.2 CYPRINIDAK sp.

Yolk-sac 6.3 PUMPKINSEED type Yolk-sac 5.1 SAMPLE DATE:

12 August START DATE and TIME:

12AUG14:21:05 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH:

SUE REPLICATE:

B VOLUME SAMPLED (gals x 10A6):

0.013684 STUDY GRAB TEMPERATURE (F):

80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.3 FOREBAY CURRENT VELOCITY (ft/sec) 1.50 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x l0^6) :

1209.6 LIFE PLUS TARA STAGE LENGTH COUNT Pimephales type Yolk-sac 4.6 Pimephales type Yolk-sac 4.8 Pimephales type Yolk-sac 5.7 Pimsephales type Yolk-sac 5.6 Pixsephales type Yolk-sac 4.7 Pimephales type Yolk-sac 4.8 D-6 0

APPENDIX D (cont.)

Pimephales type Yolk-sac 4.5 Pimephales type Yolk-sac 4.8 CYPRINIDAE sp.

Yolk-sac 4.9 CYPRINIDAE ap.

Yolk-sac 4.8 CYPRINIDAE sp.

Yolk-sac 6.9 CYPRIHIDAE sp.

Yolk-sac 7.0 CYPRINIDAS sp.

Yolk-sac 5.2 CYPRINIDAE sp.

Yolk-sac 6.7 CYPRINIDAK sp.

Yolk-sac 7.9 CYPRINIDAE sp.

Yolk-sac 6.3 CYPRINIDAE sp.

Yolk-sac 7.6 CYPRINIDAE sp.

Yolk-sac 6.5 CYPRINIDAK sp.

Yolk-sac 5.1 SAMPLE DATE:

12 August START DATE and TINE: 12AUG14:21:32 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE:

A VOLUME SAMPLED (gals x 10A6):

0.014978 STUDY GRAB TEMPERATURE (F):

80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.3 FOREBAY CURRENT VELOCITY (ft/sec):

1.60 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

1209.6 LIFE PLUS TAKA STAGE LENGTH COUNT Dorosoma sp.

Post Yolk-sac 5.8 Pimephales type Yolk-sac 4.8 CYPRINIDAE sp.

Post Yolk-sac 9.3 CYPRINIDAK ap.

Post Yolk-sac 7.9 CYPRINIDAE sp.

Post Yolk-sac 10.0 CYPRINIDAK sp.

Post Yolk-sac 6.2 CYPRINIDAE sp.

Post Yolk-sac 11.6 CYPRINIDAE sp.

Post Yolk-sac 10.5 CYPRINIDAE sp.

Post Yolk-sac 10.5 CYPRINIDAE sp.

Post Yolk-sac 7.8 CYPRINIDAE sp.

Post Yolk-sac 7.7 CYPRINIDAE sp.

Post Yolk-sac 13.6 CYPRINIDAE sp.

Post Yolk-sac 5.0 SAMPLE DATE:

12 August START DATE and TINE: 12AUG14:21:32 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: ROT REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.015262 STUDY GRAB TEMPERATURE (F) :

80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

7.3 FOREBAY CURRENT VELOCITY (ft/sac) 1.60 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Pimtephales type Yolk-sac 5.6 Pimephales type Yolk-sac 5.2 Pimephales type Yolk-sac 6.0 Pimephales type Yolk-sac 5.9 Pimephales type Yolk-sac 5.1 Pimephales type Yolk-sac 5.1 CYPRINIDAE ap.

Post Yolk-sac 8.7 CYPRIHIDAE sp.

Post Yolk-sac 9.5 CYPRINIDAX sp.

Post Yolk-sac 7.1 CYPRINIDAE sp.

Yolk-sac 4.6 PUMPKINSEED type Yolk-sac 6.7 SAMPLE DATE:

26 August START DATE and TIME: 26AUG14:16:30 SAMPLE DURATION (minutes): 25.00 DIEL PERIOD:

Day DEPTH:

SUR REPLICATE:

A VOLUME SAMPLED (gals x i0A6):

0.015189 STUDY GRAB TEMPERATURE (F):

81.1 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.1 FOREBAY CURRENT VELOCITY (ft/sec):

1.30 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals xt 10A6):

1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON

.0.,

SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:16:30 SAMPLE DURATION (minutes): 25.00 DIEL PERIOD: Day DEPTN:

SUR REPLICATE: B VOLUME SAMPLED (gals xt 10A6):

0.014638 STUDY GRAB TEMPERATURE (F):

81.1 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.1 FOREBAY CURRENT VELOCITY (ft/sac):

1.30 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals t 10^6):

1209.6 LIFE PLUS TAXA STAGE LENGTN COUNT Notropis sp.

Juvenile 18.3 SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:17:19 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Day DEPTH: BUT REPLICATE: A VOLUME SAMPLED (gals it 10A6):

0.019048 STUDY GRAB TEMPERATURE (F):

80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L):

6.9 FORENAY CURRENT VELOCITY (ft/sac):

1.60 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals t 10^6):

1209.6 LIFE PLUS TAKA STAGE LENGTH COUNT CYPRINIDAK sp.

Yolk-sac 5.8 CYPRINIDAR sp.

Yolk-sac 3.1 D-61

APPENDIX D (cant.)

SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:17:12 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Day DEPTH: ROT REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.015857 STUDY GRAB TEMPERATURE (F):

80.8 STUDY GRAB DISSOLVED OXYGEN (rag/L):

6. 9 FORERAY CURRENT VELOCITY (ft/sea):

1.60 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6):

1209.6 LIFE PLUS TAXA STAGE LENGTH COURT NO ICHTHYOPLANICTON.

0 SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:20:37 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH:

SUR REPLICATE: A VOLUME SAMPLED (gals x 10A6):

0.013773 STUDY GRAB TEMPERATURE (F):

80. 6 STUDY GRAB DISSOLVED OXYGEN (mig/L) :

7.0 FOREBAY CURRENT VELOCITY (ft/sea) 1.20 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10A6) :

1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Notropis sp.

Juvenile 13.6 Notropis sp.

Juvenile

11. 7 Pimsephales type Yolk-sac 5.2 SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:20:37 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH:

SUR REPLICATE:

B VOLUME SAMPLED (gals x i0A6):

0.013993 STUDY GRAB TEMPERATURE (F):

80.6 STUDY GRAB DISSOLVED OXYGEN (mg/L):

7.0 FOREEAY CURRENT VELOCITY (ft/sea) 1.20 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 106) 1209.6 LIFE PLUS TAKA STAGE LENGTH COUNT BULLHEAD MINNOW Juvenile 25.1 BULLHEAD MINNOW Juvenile 12.2 PUMPEINSEED type Post Yolk-sac 9.1 SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:21:08 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: ROT REPLICATE:

A VOLUME SAMPLED (gals x I0^6):

0.013304 STUDY GRAB TEMPERATURE (F):

80. 6 STUDY GRAB DISSOLVED OXYGEN (mg/L) :

7.0 FOREBAY CURRENT VELOCITY (ft/sea):

1.35 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 106) 1209.6 LIFE PLUS TAKA STAGE LENGTH COUNT Notropis sp.

Juvenile 12.1 SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:21:08 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH:

ROT REPLICATE:

B VOLUME SAMPLED (gals x 10^6):

0.014060 STUDY GRAB TEMPERATURE (F) :

80.6 STUDY GRAB DISSOLVED OXYGEN (xag/L) :

7.0 FOREBAY CURRENT VELOCITY (ft/sea) 1.35 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x i06) 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales sp.

Juvenile 9.8 D-62