Triennial Chlorine Survey Report
ML20080J666
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 03/20/2020
From: Washko J
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RA20-015
Download: ML20080J666 (29)


Text

Exelon Generation@

RA20-015 March 20, 2020 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 - 0001 LaSalle County Station, Units 1 and 2 LaSalle County Station 2601 North 21 " Road Marseilles, IL61341 815-415-2000 Telephone www.exeloncorp.com 10 CFR 50.4 Renewed Facility Operating License Nos. NPF-11 and NPF-18 NRC Docket Nos. 50-373 and 50-374

Subject:

Triennial Chlorine Survey Report Enclosed is the Exelon Generation Company, LLC, LaSalle County Station (LSCS)

Triennial Chlorine Survey Report. The survey is submitted in accordance with the provisions of the April 11, 1986, letter transmitting Amendments 38 and 20 to the LSCS Facility Operating Licenses for Units 1 and 2, respectively.

This letter contains no new regulatory commitments. Should you have any questions concerning this letter, please contact Mr. Daniel Mearhoff, Regulatory Assurance Manager, at (815) 415-2800.

Respectfully,

,_,;,{___-/

John J. Washko Site Vice President LaSalle County Station

Enclosure:

Chlorine Survey in the Vicinity of LaSalle County Generating Station cc:

Regional Administrator - NRC Region Ill NRC Senior Resident Inspector - LaSalle County Station

CHLORINE SURVEY IN THE VICINITY OF LASALLE COUNTY GENERATING STATION

1. Executive Summary A triennial survey of potential sources of chlorine was conducted by LaSalle County Station to ensure compliance with General Design Criteria (GDC) 19 of Appendix A of 10 CFR 50. The survey reevaluates use of chlorine within 5 miles of the plant's Control Room and ensures that a chlorine hazard does not exist. The survey also ensures compliance with Regulatory Guides (RG) 1.78, Revision 0, "Assumptions for Evaluating the Habitability of a Nuclear Power Plant Control Room During a Postulated Hazardous Chemical Release," and RG 1.95, Revision 0, "Protection of Nuclear Power Plant Control Room Operators Against an Accidental Chlorine Release".

A database of potential chlorine sources was built based on facilities identified in previous surveys and updated with information from the Grundy and LaSalle County Emergency Services and Disaster Agencies (ESDA). The database was limited to facilities located between the Marseilles and Dresden Island Locks and included facilities within and outside the five-mile radius of LaSalle County Station. A total of fifteen facilities in Grundy and LaSalle Counties fit the criteria and were included in this survey, of which fourteen responded.

Data from five controlling authorities and fourteen facilities was reviewed and follow-up contacts were made to confirm the information gathered. The survey identified five facilities used and stored chlorine onsite. The results of this survey indicate chlorine is used and stored in cylinders that are not larger than 150 lbs. at facilities within five miles of LaSalle Station. Also, no chlorine is transported on the Illinois River.

2. Introduction Licensing of LaSalle County Station required a survey of industries and transportation routes in the site vicinity that may use, store, and/or transport hazardous chemicals. The original survey, conducted in 1975, revealed anhydrous ammonia and probably chlorine were transported by barge on the Illinois River. The information gathered was not complete enough to conclude that chlorine was not shipped in large quantities by barge on the Illinois River.

1

A new survey was conducted in January - February 1986 to supplement the information obtained from the 1975 chlorine survey. The information collected by the 1986 survey concluded no special chlorine protection provisions were required at LaSalle County Station. In the safety evaluation supporting Amendment No. 38 to Facility Operating License No. NPF-11 and Amendment No. 20 to Facility Operating License No. NPF-18, the U.S. Nuclear Regulatory Commission (NRC) agreed with this conclusion, but recommended a three-year update for the Illinois River chlorine survey. Exelon Corporation committed to the survey update in a letter to the NRC dated March 5, 1986.

Surveys have been conducted on a 3-year frequency supporting the conclusion that chlorine is not shipped on the Illinois River in sufficient quantities to present a hazard to the LaSalle County Station Control Room. In accordance with this commitment, a new survey has been conducted.

The following sections describe regulatory guides that form the basis of the Control Room habitability evaluation, results of previous surveys, the methods and results of current survey, and the conclusion regarding chlorine as a hazard. The results of the current survey and previous surveys fully support the 1986 conclusion that no special chlorine protection measures are required at LaSalle County Station.

3. Regulatory Guides Regulatory Guide 1. 78, Revision 0, "Assumption for Evaluating the Habitability of a Nuclear Power Plant Control Room during a Postulated Hazardous Chemical Release" identifies chlorine as a hazardous chemical that requires a control room habitability analysis in the event of an accidental chlorine release from stationary or mobile sources near the station. Regulatory Guide 1.95, Revision 0, specifically addresses onsite accidental chlorine release. However, it can also be used in analyzing effects of an offsite chlorine release.

Regulatory Position 1 of Regulatory Guide 1. 78, states chlorine stored or situated at greater distances than five miles from the control room need not be considered in evaluating habitability of the nuclear power plant control room during a postulated chlorine release. Regulatory Guide 1. 78 also specifies frequency, distance, and quantity of chemicals transported or stored with respect to the Control Room that require Control Room habitability analysis. The Regulatory Guide specifies three modes of transportation that must be considered for chlorine manufactured, stored or used by industries in the vicinity of the control room: railroads, highways, and waterways.

4. Earlier Surveys of Chlorine Shipment The LaSalle County Final Safety Analysis Report (FSAR) Section 2.1.1 describes the location of the plant and transportation routes near the plant. FSAR Section 2.2.2 describes nearby industrial, transportation, and military facilities. All industrial facilities are located outside of a five-mile radius of the plant, therefore, chlorine used or stored at these facilities need not be considered in evaluating control room habitability. A survey of these industries was conducted in 1975 to determine the shipment of chlorine by three 2

modes of transportation, U.S. Highway 6 and State Highway 47, the nearest highways to the station used by these industries and the Chicago Rock Island and Pacific, the nearest railroad, are all located farther than five miles from the station. Therefore, transportation of chlorine by these two modes of transportation need not be considered in the control room habitability analysis.

FSAR Section 2.2.2.4 describes river traffic on the Illinois River passing the site. Section 2.2.3. l.c concluded the only transportation route potentially carrying chlorine within five miles of the station was the Illinois River, which is located approximately 4.7 miles north of the station. However, the available data on commodities transported on the Illinois River (FSAR Table 2.204) did not differentiate barge shipments of chlorine from other chemicals. The survey found a small quantity of chlorine was used by the Illinois Nitrogen Corporation, located at river mile 248.7, approximately five miles north of the station. There was not sufficient information available to determine if it was receiving chlorine supply by barge. In order to expedite the licensing process, chlorine detectors were provided in the Control Room HV AC system intake air ducts.

To supplement the 1975 survey and to obtain additional specific information on chlorine shipments, a survey was conducted during January-February 1986 to determine whether chlorine was transported in barges on the Illinois River.

Information was collected from the U.S. Army Corps of Engineers, the U.S. Coast Guard, and Lockmasters for Starved Rock and Dresden Dams. None of the sources had information suggesting chlorine is transported on the Illinois River. Because none of the barge operators, barge terminals, or chemical companies reported chlorine shipments on the Illinois River and neither of the lockmasters was aware of any chlorine passing through their locks, it was concluded that chlorine was not shipped on the river in significant quantities.

5. Current Survey of Chlorine Shipments The criteria used for the current survey limited sites of interest to those located between Marseilles and Dresden Island Locks and included facilities within and outside of the five-mile radius of LaSalle County Station. Previous surveys were reviewed and updated from reports from Grundy and LaSalle County Emergency Services and Disaster Agencies (ESDAs).

Table 1 shows results of the fourteen barge terminals, chemical companies, water treatment plants, and potential chlorine users that responded to the survey. None of the barge terminals located between the closest upstream and downstream dams handles chlorine. None of the chemical companies, water treatment plants or other potential chlorine users sends or receives chlorine on the Illinois River. Five facilities were identified using small quantities of chlorine. Two of these sites are located within five miles of LaSalle County Station. All five facilities stated their chlorine is transported and stored in 150- lb. cylinders via highway. CSX Railroad currently operates the closest 3

regularly traveled railroad to LaSalle Station. The railroad is located outside the five-mile radius of LaSalle Station.

Table 2 shows the results of five government agencies, public officials, and trade organizations contacted for the survey. The Chlorine Institute reported no chlorine is transported on the Illinois River, and has no knowledge of any chlorine producer or distributor located on the river. The United States Coast Guard stated that any company transporting chlorine on a barge is required to notify them and that they have not received such notification for the Illinois River.

In addition, the LaSalle County Station HAZMA T Coordinator reported no chlorine was used or stored on-site in single 150-lb. cylinders.

6. Conclusion of Findings The current survey concludes chlorine is not transported in any significant quantities on the Illinois River nor within a five-mile radius of LaSalle County Station. Small quantities of chlorine are used and stored in 150-lb. cylinders at five sites. Two of the five sites identified are within the five-mile radius of LaSalle Station. Regulatory Guide 1.95 C.3 states that only single container quantities exceeding 150-lb. need to be considered for Control Room ventilation requiring automatic chlorine protection features.

Therefore, the survey concludes that chlorine detectors are not required for LaSalle County Station.

4

Table 1. Barge Terminals, Chemical Companies, Water Treatment Plants, and Other Potential Chlorine Users in Towns on the Illinois River in the Vicinity of LaSalle Station Company County Address Phone Distance to Chlorine Identified?

LaSalle Station Cargill Inc.

LaSalle S. Main Street (815) 357-8760

<5 miles None Seneca POC: Janelle Beck Agrium US Inc.

LaSalle 2100 E. Broadway (815) 795-4151

>5 miles None Marseilles POC: Beth Cosby Morris Sewage Treatment Grundy N. River Road (815) 942-0643

>5 miles Yes Plant Morris 12 x 150 lb. cylinders POC: Brent Pierce 2 x I-ton cylinders HB Fuller Grundy DuPont Road (815) 357-8215

>5 miles None Seneca POC: Dan Deacon Growmark LaSalle P.O. Box 380 (815) 357-6721

<5 miles None Seneca POC: Jerry Anderson Marseilles Wastewater LaSalle

  1. 2 Spicer Lane (815) 795-2150

>5 miles Yes, 150 lb. Cyl. 1 Treatment Facility Marseilles and stored inside 5-mile POC: Jason Rix

< 5 miles radius 6-8 stored outside 5-mile radius Village of Seneca Wastewater LaSalle 301 W. Union (815) 326-0840

> 5 miles Yes Treatment Facility Seneca 10 x 150 lb. cylinders POC: Jim Applebee 2 x 1-ton liquid chlorine ADM/Growmark LaSalle Towpath Road (815) 433-3636

>5 miles None Ottawa POC: Becca Serena CF Industries, Inc.

Grundy 73 7 E. DuPont Road (815) 357-8811

>5 miles None Seneca POC: Ryan Caba 5

Dyno Nobel Grundy 7700 DuPont Road (815) 942-5800

>5 miles None Morris POC: Rich Pugh Sabic Innovative Plastics LaSalle 2148 N 2753rd Rd (815) 434-7000

> 5 miles Yes Ottawa, IL ext. 7621 8 x 150 lb. cylinders POC: Dave Parrot Marseilles Streets Dept.

LaSalle Well House #4 815-795-4000 Yes (Various well houses)

Well House #5

  1. 4 > 5 miles 5 x 150 lb. cylinders Well House #6
  1. 5 > 5 miles 4 x 150 lb. cylinders POC: Paul Rivett
  1. 6 < 5 miles 2 x 150 lb. cylinders Air Products and Grundy 8805 Tabler Rd 815-223-2924

> 5 miles None Manufacturing Morris POC: Kurt Serrine Miller and Company Grundy 444 Shipyard Road 815-357-1400

<5 miles None Seneca Ext. 2725 POC: Jessica Paulsen 6

Table 2. Government Agencies, Public Officials and Trade Organizations Organization Information that Chlorine is Transported on the Illinois River Chlorine Institute, Rosslyn, VA None Lockmaster, Marseilles, Illinois None Emergency Services and Disaster Agency of LaSalle County, Ottawa, IL None Emergency Services and Disaster Agency of Grundy County, Morris, IL None U.S. Coast Guard, Chicago, IL.

None 7

7. References Chlorine Institute, Rosslyn, VA, Ms. Robin Kinsley, Email correspondence with Exelon Corporation on 3/6/20, (703) 894-4140, robyn.kinsley@cl2.com Lockmaster, Marseilles Lock and Dam, Marseilles, Illinois, (815) 795-2593, Mr. Clifford Wright, Telephone conversation with Exelon Corporation on 3/4/20.

Grundy County Emergency Services and Disaster Agency, (815) 941-3200, Mr. Joe Schroeder, Voice mail conversation with Exelon Corporation on 3/9/20.

LaSalle County Emergency Services and Disaster Agency, (815) 433-5622, Mr. Fred Moore, Telephone conversation with Exelon Corporation on 3/4/20.

Cargill Inc., Seneca, Illinois, (815) 357-8760, Ms. Janelle Beck, Telephone conversation with Exelon Corporation on 3/4/20.

Agrium US Inc, Marseilles, Illinois, (815) 795-4151, Ms. Beth Cosby, Telephone conversation with Exelon Corporation on 3/4/20.

Morris Sewage Treatment Plant, Morris, Illinois, (815) 942-0643, Mr. Brent Pierce, Telephone conversation with Exelon Corporation on 3/6/20.

HB Fuller, Seneca, Illinois, (815) 357-8215, Mr. Dan Deacon, Telephone conversation with Exelon Corporation on 3/4/20.

Growmark, Seneca, Illinois, (815) 357-6721, Mr. Jerry Anderson, Telephone conversation with Exelon Corporation on 3/4/20.

Wastewater Treatment Facility, Marseilles, Illinois, (815) 795-2150, Mr. Jason Rix, Telephone conversation with Exelon Corporation on 3/4/20.

Village of Seneca Wastewater Treatment Facility, Seneca, Illinois, (815) 326-0840, Mr. Jim Applebee, Telephone conversation with Exelon Corporation on 3/4/20.

ADM/Growmark, Ottawa, Illinois, (815) 433-3636, Ms. Becca Serena, Telephone conversation with Exelon Corporation on 3/4/20.

CF Industries, Inc., Seneca, Illinois, (815) 357-8811, Mr. Ryan Caba, Telephone conversation with Exelon Corporation on 3/4/20.

8

Dyno Nobel, Morris, Illinois, (815) 942-5800, Mr. Rich Pugh Telephone conversation with Exelon Corporation on 3/4/20.

US Coast Guard, Chicago, Illinois, (630) 986-2147, Petty Officer Zachary Strack, Telephone conversation with Exelon Corporation on 3/4/20.

Sabic Innovative Plastics, Ottawa, Illinois, (815) 434-7000 ext. 7621, Mr. Dave Parrott, Voice mail exchange with Exelon Corporation on 3/6/20.

Air Products and Manufacturing Corp, Morris, Illinois, (815) 223-2924, Mr. Kurt Serrine, Telephone conversation with Exelon Corporation on 3/6/20.

Marseilles Streets Department, Marseilles, Illinois (815) 795-4000, Mr. Paul Rivett, Telephone conversation with Exelon Corporation on 3/6/20.

Miller and Company, Seneca, Illinois (815) 357-1400 ext. 2725, Ms. Jessica Paulsen, Telephone conversation with Exelon Corporation on 3/10/20.

9

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Air Products and Manufacturing, Morris, IL Point of Contact Kurt Serrine

~~~~~~~~~~~~~~~~-

Telephone Number (815) 223-2924 Date Contacted 316120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Mode of transportation Quantity stored Size of Container Chlorine Stored in Quantity Transported Stored Used Manufactured Transported Rail Road Highway Waterway NIA NIA NIA NIA NIA Yes 150 lbs. Max. per RG 1.95 NIA No x x x x Note: NIA may be entered in the inapplicable portions of this form.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Cargill, Inc Point of Contact Janelle Beck, Supervisor Telephone Number (815) 357-8760 Date Contacted 314120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Mode of transportation Stored Used Manufactured Transported Rail Road Highway Waterway Quantity stored NIA Size of Container Chlorine NI A NIA NIA NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NIA Note: NIA may be entered in the inapplicable portions of this form.

No chlorine is stored, used or handled.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 x

x x

x LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Agrium Point of Contact Beth Cosby Telephone Number (815) 795-4151 Date Contacted 314120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Stored Used Manufactured Transported Mode of transportation Rail Road NIA Highway NIA Waterway NIA Quantity stored NIA Size of Container Chlorine NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NIA Note: NIA may be entered in the inapplicable portions of this form.

No chlorine is stored, used or handled.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 x x x x LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Morris Sewage Treatment Plant Point of Contact Brent Pierce

~~~~~~~~~----~~~~~~~

Telephone Number (815) 942-0643 Date Contacted 316120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Mode of transportation Quantity stored Stored Used Manufactured Transported Rail Road Highway Waterway Yes x

x x

Fourteen (14) cylinders No x

x Size of Container Chlorine Stored in Twelve 150 lbs cylnders and two 1 ton cylinders 150 lbs. Max. per RG 1.95 Quantity Transported NIA Note: NI A may be entered in the inapplicable portions of this form.

Transported from Willow Springs, IL or potentially from Hawkins Chemical in Bourbonnais (IR not required since facility is outside the 5 mile radius.)

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted =H=B-.....-..F=u=ll..;;.;er'------------

Point of Contact _ _..D

..... a... n ___

D"'"'"e"""'a.....

co"""n-...-__...P..... la

..... n-..t._.M.........,a __ n __ a...,ge.... r,___ _________ _

Telephone Number (815) 357-8215 Date Contacted 314120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Mode of transportation Stored Used Manufactured Transported Rail Road Highway Waterway Quantity stored NI A Size of Container Chlorine NI A NIA NIA NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NI A Note: NIA may be entered in the inapplicable portions of this form.

No chlorine is stored, used or handled.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 x

x x

x LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted.... G.... r....

ow..........,m...... a.... rk _________ _

Point of Contact Jerry Anderson Plant Manager Telephone Number (815) 357-6721 Date Contacted 314120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Mode of transportation Stored Used Manufactured Transported Rail Road Highway Waterway Quantity stored NI A Size of Container Chlorine NIA NIA NIA NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NIA Note: NIA may be entered in the inapplicable portions of this form.

No chlorine is stored, used or handled.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 x

x x

x LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Marseilles Wastewater Treatment Facility Point of Contact Jason Rix Telephone Number (815) 795-2150 Date Contacted 3/4/20 Distance from LCGS X (South)

X (North)

Chlorine Use Mode of transportation Less than 5 Miles Stored Used Manufactured Transported Rail Road Highway Waterway x

Greater than 5 Miles Yes No x

x x

x Quantity stored North Facility - six to eight (6-8) cylinders ;

South Facility - one (1) cylinder Size of Container Chlorine 150 lbs.

Stored in 150 lbs. Max. per RG 1.95 Quantity Transported

___.... N..... I A....._ _____ _

Note: NIA may be entered in the inapplicable portions of this form.

Seasonal usage during the months of May - October but stored year around.

North Facility-No. 2 Spicer Road Marseilles, IL South Facility (Lagoon) - 2425th Road Marseilles, IL Survey Conducted by Level of Use Reference James J. DiCola 7 of7 LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Seneca Wastewater Treatment Facility Point of Contact Jim Applebee Telephone Number (815) 326-0840 Date Contacted 314120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Mode of transportation Stored Used Manufactured Transported Rail Road Highway Waterway Quantity stored ten cylinders x

Size of Container Chlorine 150 lbs.

Yes x

x x

Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NI A No Note: NI A may be entered in the inapplicable portions of this form.

x x

Transported about 1 mile from water plant to the Waste Water Treatment Facility (WWTF)

Added the following Chlorine Storage at Excess Flow Facility: _________ _

One ton liguid chlorine (98%) in use One ton liguid chlorine (98%) standby (IR not required since facility is outside the 5 mile radius.)

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted ADM I Growmark Point of Contact Becca Serena Telephone Number (815) 433-3636 Date Contacted 314120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Stored Used Manufactured Transported Mode of transportation Rail Road NIA Highway NIA Waterway NIA Quantity stored NIA Size of Container Chlorine NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NIA Note: NI A may be entered in the inapplicable portions of this form.

No chlorine is stored, used or handled.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 x x x x LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted CF Industries Point of Contact _

_ R.... v......

an____.C....... a...... b...... a _________ _

Telephone Number (815) 357-8811 Date Contacted 314120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Mode of transportation Stored Used Manufactured Transported Rail Road Highway Waterway Quantity stored NI A Size of Container Chlorine NIA NIA NIA NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NIA Note: NIA may be entered in the inapplicable portions of this form.

No chlorine is stored, used or handled.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 x x x

x LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted =D....

y=n"""o..... N.;..;;;o""'b...;;;.el"'-----------

Point of Contact _...... R._i.... c=h..-P..... u...,g,,_h..__ ________ _

Telephone Number (815) 942-5800 Date Contacted 314120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Stored Used Manufactured Transported Mode of transportation Rail Road NIA Highway NIA Waterway NIA Quantity stored NIA Size of Container Chlorine NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NIA Note: NI A may be entered in the inapplicable portions of this form.

No chlorine is stored, used or handled.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 x

x x

x LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Sabic Innovative Plastics Point of Contact Dave Parrott Telephone Number (815) 434-7000 x7621 Date Contacted 316120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Mode of transportation Quantity stored Size of Container Chlorine Stored in Quantity Transported Stored Used Manufactured Transported Rail Road Highway Waterway x

Eight cylinders 150 lbs.

x x 150 lbs. Max. per RG 1.95 NIA Note: NIA may be entered in the inapplicable portions of this form.

Transported via Rockford area Survey Conducted by Level of Use Reference James J. DiCola 7 of7 x x LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Marseilles Streets Dept. - Various Marseilles Well houses Point of Contact Paul Rivett

~--............__..................._~~~~~~~~~~

Telephone Number (815) 795-4000 Date Contacted 3/6/20 Distance from LCGS x

x Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Mode of transportation Stored Used Manufactured Transported Rail Road Highway Waterway Quantity stored See below x

Size of Container Chlorine 150 lbs.

x x

Stored in 150 lbs. Max. per RG 1.95 Quantity Transported N_/A ______ _

Note: NI A may be entered in the inapplicable portions of this form.

Well house #4-5 x 150 lb cylinders located> 5 miles Well house #5 - 4 x 150 lb cylinders located > Smiles Well house #6-2 x 150 lb cylinders located< 5 miles Survey Conducted by Level of Use Reference James J. DiCola 7 of7 x x LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Miller & Company Point of Contact Jessica Paulsen Telephone Number (815) 357-1400, ext 2725 Date Contacted 3110120 Distance from LCGS x

Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Mode of transportation Quantity stored Stored Used Manufactured Transported Rail Road Highway Waterway NIA NIA NIA NIA NIA NIA NIA NIA Size of Container Chlorine NI A Stored in 150 lbs. Max. per RG 1.95 Quantity Transported

_______ N I A __________ _

Note: NI A may be entered in the inapplicable portions of this form.

They said no chlorine is used or stored onsite.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 NIA NIA NIA NIA LCP-840-23 Revision 1 September 10, 2007

.v**

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Chlorine Institute (Table 2)

Point of Contact Robin Kinsley (email: robyn.kinsley@cl2.com Telephone Number (703) 894-4140x. 4123 Date Contacted __

3_16_12_0 __ _

Distance from LCGS NI A NIA Less than 5 Miles Greater than 5 Miles Chlorine Use Mode of transportation Stored Used Manufactured Transported Rail Road Highway Waterway Yes NIA NIA NIA NIA NIA NIA NIA Quantity stored N_IA _____ _

Size of Container Chlorine NI A Stored in 150 lbs. Max. per RG 1.95 Quantity Transported

.....;;..N;.;..;I A;..;;;.... ____ _

No Note: NIA may be entered in the inapplicable portions of this form.

NIA NIA NIA NIA Email Correspondence from Robyn Kinsley: I can tell you that there are zero chlorine production facilities within 5 miles of your facility. There also are zero packaging facilities within 5 miles - the closest are in Willow Springs and Lemont, both over 60 miles out I believe.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Marseilles Lock and Dam (Table 2)

Point of Contact Clifford Wright, Lockrnaster

~~---...;;====""'"'-'-"""'""'....... -=..;~=----~ -~~~~~~~~~

Telephone Number (815) 795-2593 Date Contacted_-"'3_14...... 12_0....._ __

Distance from LCGS X (Dam location)

Less than 5 Miles Greater than 5 Miles Chlorine Use Mode of transportation Stored Used Manufactured Transported Rail Road Highway Waterway Quantity stored NI A Size of Container Chlorine NI A Yes NIA NIA NIA Stored in 150 lbs. Max. per RG 1. 9 5 Quantity Transported NI A No NIA NIA NIA NIA Note: NIA may be entered in the inapplicable portions of this form.

NIA NIA NIA NIA They checked their database and chlorine is not identified as a shipment.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted LaSalle County Emergency Services and Disaster Agency (ESDA)

(Table 2)

Point of Contact Fred Moore

~~~

........... ----~----~~~~~~~~~~~~~~~~

Telephone Number (815) 433-5622 Date Contacted 314120 Distance from LCGS NIA NIA Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Stored NIA NIA Used NIA NIA Manufactured NIA NIA Transported NIA NIA Mode of transportation Rail Road NIA Highway NIA Waterway NIA Quantity stored NIA Size of Container Chlorine NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NIA Note: NI A may be entered in the inapplicable portions of this form.

They said no new businesses handle chlorine in LaSalle County other than Sabic. They do not receive any information on transportation.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted Grundy County Emergency Services and Disaster Agency (ESDA) (Table 2)

Point of Contact Joe Schroeder Telephone Number (815) 941-3200 Date Contacted 319120 Distance from LCGS NIA NIA Less than 5 Miles Greater than 5 Miles Chlorine Use Yes No Stored NIA NIA Used NIA NIA Manufactured NIA NIA Transported NIA NIA Mode of transportation Rail Road NIA Highway NIA Waterway NIA Quantity stored NIA Size of Container Chlorine NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NIA Note: NIA may be entered in the inapplicable portions of this form.

They only receive information related to Tier 2 surveys which deal with on-site storage.

They do not receive any info on transportation. Mr. Schroeder explained that there is no chlorine used or stored within a five mile radius of the station.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 LCP-840-23 Revision 1 September 10, 2007

ATTACHMENT A LASALLE COUNTY STATION CHLORINE SURVEY 2020 Year Organization Contacted US Coast Guard (Table 2)

Point of Contact --'P'""'e.... t.._.ty._O"""""'ffi=1c"""e"""r"'""Z=a;.;..;c=h=a"""ry""""""S"""tr'""a""'c""'k'"-----------

Telephone Number (630) 986-2147 Date Contacted _ ___...3....,14..... 12..... 0....._ __

Distance from LCGS NI A NIA Less than 5 Miles Greater than 5 Miles Chlorine Use Mode of transportation Stored Used Manufactured Transported Rail Road Highway Waterway Quantity stored NI A Size of Container Chlorine NIA Yes NIA NIA NIA Stored in 150 lbs. Max. per RG 1.95 Quantity Transported NIA No NIA NIA NIA NIA Note: NI A may be entered in the inapplicable portions of this form.

NIA NIA NIA NIA Individual was unaware of any large quantities of chlorine shipped on the Illinois River.

They would only track these if it were a bulk transfer to a barge. Individual quantities of chlorine in #150 cylinders or less may not be individually declared.

Survey Conducted by Level of Use Reference James J. DiCola 7 of7 LCP-840-23 Revision 1 September 10, 2007