TAC:ME3374, Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5B (Approved, Closed) TAC:ME3375, Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5B (Approved, Closed) TAC:ME3376, Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5B (Open) TAC:ME3377, Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5B (Open) |
|
MONTHYEARRS-10-032, Application for Technical Specification Change Regarding Risk-informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program (Adoption of TSTF-425, Revision 3)2010-02-16016 February 2010 Application for Technical Specification Change Regarding Risk-informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program (Adoption of TSTF-425, Revision 3) Project stage: Request RS-10-024, Application for Technical Specification Change Re Risk-Informed Justification for Relocation of Specific Surveillance Frequency Requirements to Licensee Controlled Program2010-02-16016 February 2010 Application for Technical Specification Change Re Risk-Informed Justification for Relocation of Specific Surveillance Frequency Requirements to Licensee Controlled Program Project stage: Request ML1012411622010-05-14014 May 2010 Request for Additional Information, Regarding an Amendment Request to Relocate Specific Surveillance Frequency Requirements to a Licensee-Controlled Program Project stage: RAI ML1011905932010-05-17017 May 2010 Request for Additional Information Regarding an Amendment Request to Relocate Specific Surveillance Frequency Requirements to a Licensee Controlled Program Project stage: RAI RS-10-108, Additional Information Supporting Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program2010-06-22022 June 2010 Additional Information Supporting Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program Project stage: Request RS-10-107, Additional Information Supporting Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program2010-06-22022 June 2010 Additional Information Supporting Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program Project stage: Request ML1019404222010-07-21021 July 2010 RAI, Related to Risk-Informed Relocation of Specific Surveillance Frequency Requirements Project stage: RAI RS-10-138, Additional Information Supporting Application for Technical Specification Change Re Risk-Informed Justification for Relocation of Specific Surveillance Frequency Requirements to Licensee Control Program2010-08-13013 August 2010 Additional Information Supporting Application for Technical Specification Change Re Risk-Informed Justification for Relocation of Specific Surveillance Frequency Requirements to Licensee Control Program Project stage: Request ML1029202602011-02-18018 February 2011 Issuance of Amendments 248 & 243, Regarding Risk-informed Justification for the Relocation of Specific Surveillance Frequency Requirement to a Licensee-controlled Program Project stage: Approval 2010-06-22
[Table View] |
|
---|
Category:Letter type:RS
MONTHYEARRS-24-001, Response to Request for Additional Information Regarding Relief Request I5R-26, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval2024-01-0303 January 2024 Response to Request for Additional Information Regarding Relief Request I5R-26, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval RS-23-128, Response to Request for Additional Information for the Emergency License Amendment Request Increase Technical Specifications Completion Time in TS 3.8.1.B.4 from 7 Days to 30 Days2023-12-15015 December 2023 Response to Request for Additional Information for the Emergency License Amendment Request Increase Technical Specifications Completion Time in TS 3.8.1.B.4 from 7 Days to 30 Days RS-23-123, Emergency License Amendment Request - Increase Technical Specifications Completion Time in TS 3.8.1.B.4 from 7 Days to 30 Days2023-12-13013 December 2023 Emergency License Amendment Request - Increase Technical Specifications Completion Time in TS 3.8.1.B.4 from 7 Days to 30 Days RS-23-121, Sixth Ten-Year Interval Inservice Testing Program2023-11-30030 November 2023 Sixth Ten-Year Interval Inservice Testing Program RS-23-104, Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-11-17017 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation RS-23-119, Supplemental Information Letter for Part 73 Exemption Request - Responses to Request for Confirmatory Information2023-11-10010 November 2023 Supplemental Information Letter for Part 73 Exemption Request - Responses to Request for Confirmatory Information RS-23-107, Relief Request I5R-22, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval2023-11-0808 November 2023 Relief Request I5R-22, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval RS-23-113, Submittal of Updated Final Safety Analysis Report (Ufsar), Revision 17 and Fire Protection Report (Fpr), Revision 262023-10-20020 October 2023 Submittal of Updated Final Safety Analysis Report (Ufsar), Revision 17 and Fire Protection Report (Fpr), Revision 26 RS-23-102, Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-10-16016 October 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation RS-23-097, Constellation Energy Generation, LLC, Advisement of Leadership Changes and Submittal of Updated Standard Practice Procedures Plans2023-10-12012 October 2023 Constellation Energy Generation, LLC, Advisement of Leadership Changes and Submittal of Updated Standard Practice Procedures Plans RS-23-089, Sixth Ten-Year Interval Inservice Testing Program2023-09-0505 September 2023 Sixth Ten-Year Interval Inservice Testing Program RS-23-071, Application to Adopt TSTF-564, Safety Limit MCPR2023-08-30030 August 2023 Application to Adopt TSTF-564, Safety Limit MCPR RS-23-080, Constellation Energy Generation, LLC, Application to Revise Technical Specifications to Adopt TSTF-264-A, Revision 0, 3.3.9 and 3.3.10 - Delete Flux Monitors Specific Overlap Requirement SRs2023-08-30030 August 2023 Constellation Energy Generation, LLC, Application to Revise Technical Specifications to Adopt TSTF-264-A, Revision 0, 3.3.9 and 3.3.10 - Delete Flux Monitors Specific Overlap Requirement SRs RS-23-086, Relief Request I5R-26, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval2023-08-28028 August 2023 Relief Request I5R-26, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval RS-23-078, Supplement to License Amendment Request to Revise Technical Specification 3.1.4, Control Rod Scram Times2023-06-16016 June 2023 Supplement to License Amendment Request to Revise Technical Specification 3.1.4, Control Rod Scram Times RS-23-077, Response to NRC Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations2023-06-16016 June 2023 Response to NRC Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations RS-23-060, Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems, and Components for Nuclear Power Reactors2023-06-0808 June 2023 Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems, and Components for Nuclear Power Reactors RS-23-059, License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b2023-06-0808 June 2023 License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b RS-23-042, Application to Revise Technical Specifications to Adopt TSTF-580, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling2023-05-25025 May 2023 Application to Revise Technical Specifications to Adopt TSTF-580, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling RS-23-070, Supplement to License Amendment Request Regarding Transition to GNF3 Fuel2023-05-16016 May 2023 Supplement to License Amendment Request Regarding Transition to GNF3 Fuel RS-22-067, 10 CFR 50.46 Annual Report2023-05-0404 May 2023 10 CFR 50.46 Annual Report RS-23-068, Response to Request for Additional Information for Quad Cities Relief Request I6R-11, Proposed Alternatives for a Temper Bead Weld Repair of the Mating Surfaces of the Reactor Pressure Vessel Head and Shell2023-04-28028 April 2023 Response to Request for Additional Information for Quad Cities Relief Request I6R-11, Proposed Alternatives for a Temper Bead Weld Repair of the Mating Surfaces of the Reactor Pressure Vessel Head and Shell RS-23-058, Submittal of Sixth Inservice Inspection Interval Relief Request I6R-11 Proposed Alternatives for a Temper Bead Weld Repair of the Mating Surfaces of the Reactor Pressure Vessel Head and Shell Flanges2023-04-24024 April 2023 Submittal of Sixth Inservice Inspection Interval Relief Request I6R-11 Proposed Alternatives for a Temper Bead Weld Repair of the Mating Surfaces of the Reactor Pressure Vessel Head and Shell Flanges RS-23-057, Supplement to License Amendment Request Regarding Transition to GNF3 Fuel2023-04-17017 April 2023 Supplement to License Amendment Request Regarding Transition to GNF3 Fuel RS-23-049, Constellation Energy Generation, LLC, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-23023 March 2023 Constellation Energy Generation, LLC, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations RS-23-041, Response to Request for Additional Information for Alternative Request RV-23H2023-03-14014 March 2023 Response to Request for Additional Information for Alternative Request RV-23H RS-23-007, Application to Adopt TSTF-564, Safety Limit MCPR2023-03-0303 March 2023 Application to Adopt TSTF-564, Safety Limit MCPR RS-23-045, Constellation Energy Generation, LLC Submittal of Fitness for Duty Performance Data Reports for 2022 Per 10 CFR 26.717(c) & 10 CFR 26.2032023-02-28028 February 2023 Constellation Energy Generation, LLC Submittal of Fitness for Duty Performance Data Reports for 2022 Per 10 CFR 26.717(c) & 10 CFR 26.203 RS-23-032, Application to Move SR 3.5.1.2 Note to LCO 3.5.1 in Accordance with TSTF-416, LPCI Valve Alignment Verification Note Location2023-02-0303 February 2023 Application to Move SR 3.5.1.2 Note to LCO 3.5.1 in Accordance with TSTF-416, LPCI Valve Alignment Verification Note Location RS-23-034, Notification of Extension to the Fifth Ten-Year Interval of the Inservice Testing Program2023-02-0202 February 2023 Notification of Extension to the Fifth Ten-Year Interval of the Inservice Testing Program RS-23-003, Constellation Energy Generation, LLC, Summary of Changes to Quality Assurance Topical Report, NO-AA-10, and Decommissioning Quality Assurance Program, NO-DC-102023-01-31031 January 2023 Constellation Energy Generation, LLC, Summary of Changes to Quality Assurance Topical Report, NO-AA-10, and Decommissioning Quality Assurance Program, NO-DC-10 RS-23-033, Request for Exemption from 10 CFR 2.109(b)2023-01-27027 January 2023 Request for Exemption from 10 CFR 2.109(b) RS-23-004, Response to Request for Additional Information Regarding Transition to GNF3 Fuel License Amendment Request2023-01-23023 January 2023 Response to Request for Additional Information Regarding Transition to GNF3 Fuel License Amendment Request RS-23-005, Response to Request for Additional Information for Quad Cities Relief Request RV-04, Inservice Testing of High Pressure Coolant Injection Drain Pot Solenoid Valves2023-01-17017 January 2023 Response to Request for Additional Information for Quad Cities Relief Request RV-04, Inservice Testing of High Pressure Coolant Injection Drain Pot Solenoid Valves RS-22-127, Submittal of Sixth Inservice Inspection Interval Relief Request I6R-10 Reactor Pressure Vessel Penetration N-11B Repair2022-12-14014 December 2022 Submittal of Sixth Inservice Inspection Interval Relief Request I6R-10 Reactor Pressure Vessel Penetration N-11B Repair RS-22-126, Constellation Energy Generation, LLC - Request to Use Provisions of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI2022-11-30030 November 2022 Constellation Energy Generation, LLC - Request to Use Provisions of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI RS-22-121, Notice of Intent to Pursue Subsequent License Renewal Applications2022-11-0909 November 2022 Notice of Intent to Pursue Subsequent License Renewal Applications RS-22-117, Response to Request for Additional Information License Amendment Request Regarding New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies2022-11-0303 November 2022 Response to Request for Additional Information License Amendment Request Regarding New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies RS-22-116, Submittal of Relief Requests Associated with the Sixth Inservice Testing Interval2022-11-0101 November 2022 Submittal of Relief Requests Associated with the Sixth Inservice Testing Interval RS-22-119, Withdrawal of Relief Request RV-11 Associated with the Sixth Inservice Testing Interval2022-10-31031 October 2022 Withdrawal of Relief Request RV-11 Associated with the Sixth Inservice Testing Interval RS-22-115, Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors2022-10-19019 October 2022 Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors RS-22-109, Response to Request for Additional Information License Amendments Related to Fuel Storage2022-10-12012 October 2022 Response to Request for Additional Information License Amendments Related to Fuel Storage RS-22-112, Submittal of RV-04 Relief Request Associated with the Sixth Inservice Testing Interval2022-10-0707 October 2022 Submittal of RV-04 Relief Request Associated with the Sixth Inservice Testing Interval RS-22-108, Response to Request for Additional Information LaSalle County Station, Units 1 and 2 and Quad Cities Nuclear Power Station, Units 1 and 2 License Amendments Related to Fuel Storage2022-10-0505 October 2022 Response to Request for Additional Information LaSalle County Station, Units 1 and 2 and Quad Cities Nuclear Power Station, Units 1 and 2 License Amendments Related to Fuel Storage RS-22-092, Nine and Quad Cities - Application to Revise Primary Containment Isolation Instrumentation Technical Specifications in Accordance with TSTF-306, Revision 2, Add Action to LCO 3.3.6.1 to Give Option to Isolate the Penetration2022-10-0303 October 2022 Nine and Quad Cities - Application to Revise Primary Containment Isolation Instrumentation Technical Specifications in Accordance with TSTF-306, Revision 2, Add Action to LCO 3.3.6.1 to Give Option to Isolate the Penetration RS-22-066, License Amendment Request to Revise Technical Specification 3.1.4, Control Rod Scram Times2022-08-25025 August 2022 License Amendment Request to Revise Technical Specification 3.1.4, Control Rod Scram Times RS-22-093, Advisement of Leadership Changes for Constellation Energy Generation, LLC and Submittal of Updated Standard Practice Procedures Plans2022-08-18018 August 2022 Advisement of Leadership Changes for Constellation Energy Generation, LLC and Submittal of Updated Standard Practice Procedures Plans RS-22-065, License Amendment Request Regarding Transition to GNF3 Fuel2022-08-18018 August 2022 License Amendment Request Regarding Transition to GNF3 Fuel RS-22-102, Supplement to Request to Revise Technical Specification 3.1.4, Control Rod Scam Times2022-08-18018 August 2022 Supplement to Request to Revise Technical Specification 3.1.4, Control Rod Scam Times RS-22-095, Response to Request for Additional Information Regarding Request to Expand Applicability of GNF Thermal Mechanical Analysis Methods to Framatome Fuel2022-08-10010 August 2022 Response to Request for Additional Information Regarding Request to Expand Applicability of GNF Thermal Mechanical Analysis Methods to Framatome Fuel 2024-01-03
[Table view] |
Text
www.exeloncorp.com Exelon Generation 4300 Winfield Road Nuclear Warrenville, IL60555 10 CFR 50.90 RS-10-138 August 13, 2010 U. S. Nuclear Regulatory Commission AnN: Document Control Desk Washington, DC 20555 Dresden Nuclear Power Station, (DNPS) Units 2 and 3 Renewed Facility Operating License Nos. DPR-19 and DPR-25 NRC Docket Nos. 50-237 and 50-249 Quad Cities Nuclear Power Station, (QCNPS) Units 1 and 2 Renewed Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265
Subject:
Additional Information Supporting Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program
References:
- 1. DNPS letter from J. L. Hansen (Exelon Generation Company, LLC) to U. S.
NRC, "Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program (Adoption of TSTF-425, Revision 3), II dated February 16, 2010 (ADAMS Accession No. ML100480330)
- 2. QCNPS letter from J. L. Hansen (Exelon Generation Company, LLC) to U. S.
NRC, "Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program (Adoption of TSTF-425, Revision 3)," dated February 16, 2010 (ADAMS Accession No. ML100480339)
- 3. Letter from C. Gratton (U.S. NRC) to M. J. Pacilio (Exelon Nuclear), IIDresden Nuclear Power Station, Units 2 and 3, and Quad Cities Nuclear Power Station, Units 1 and 2 - Request for Additional Information Related to the Risk-Informed Relocation of Specific Surveillance Frequency Requirements (TAC Nos. ME3374 through ME3377)," dated July 21,2010
August 13, 2010 U.S. Nuclear Regulatory Commission Page 2 In References 1 and 2, Exelon Generation Company, LLC (EGC) requested an amendment to Facility Operating License Nos. OPR-19, DPR-25, OPR-29 and OPR-30 for Dresden Nuclear Power Station (DNPS), Units 2 and 3, and Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2, respectively. The proposed change modifies the DNPS and QCNPS Technical Specifications (TS) by relocating specific surveillance frequencies to a licensee-controlled program. The change requested is consistent with NRC-approved Technical Specifications Task Force TSTF-425, "Relocate Surveillance Frequencies to Licensee Control- RITSTF Initiative 5b," Revision 3. The NRC requested additional information to support review of the proposed change in Reference 3. In response to this request, EGC is providing the attached information.
EGC has reviewed the information supporting a finding of no significant hazards consideration, and the environmental consideration, that were previously provided to the NRC in Attachments 6 and 1, respectively, of References 1 and 2. The additional information provided in this submittal does not affect the bases for concluding that the proposed license amendments do not involve a significant hazards consideration. In addition, the additional information provided in this submittal does not affect the bases for concluding that neither an environmental impact statement nor an environmental assessment needs to be prepared in connection with the proposed amendments.
There are no regulatory commitments contained in this letter. Should you have any questions concerning this letter, please contact Mr. Mitchel A. Mathews at (630) 657-2819.
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 13th day of August 2010.
Attachment:
Response to Request for Additional Information cc: Illinois Emergency Management Agency - Division of Nuclear Safety
ATTACHMENT Response to Request for Additional Information NRC Request In each application, the licensee included an evaluation of proposed changes in Attachment 1.
Attachment 1, Item #2 in each application stated the following:
The insert provided in TSTF-425 to replace text in the [Technical Specification] TS Bases describing the basis for each frequency relocated to the [Surveillance Frequency Control Program] SFCP has been revised from, The Surveillance Frequency is based on operating experience, equipment reliability, and plant risk and is controlled under the Surveillance Frequency Control Program," to read The Frequency may be based on factors such as operating experience, equipment reliability, or plant risk, and is controlled under the Surveillance Frequency Control Program." This deviation is necessary to reflect the [DNPS/QCNPS] basis for frequencies which do not, in all cases, base frequency on operating experience, equipment reliability and plant risk.
TSTF-425, Revision 3, "Relocate Surveillance Frequencies to Licensee Control- RITSTF Initiative 5b," (ADAMS Accession Nos. ML090850627, ML090850630, ML090850638, and ML090850640) was approved by Notice of Availability published in the Federal Register on July 6, 2009. TSTF-425, Rev. 3 involves the relocation of most time-based surveillance frequencies to a licensee controlled program, called the Surveillance Frequency Control Program (SFCP), and adds the SFCP to the administrative controls section of the technical specifications (TSs). The SFCP does not include surveillance frequencies that are event driven, controlled by an existing program, or are condition-based.
Part of the TSTF-425 change to NUREG 1430 - 1434 (Standard Technical Specifications) provides an optional insert (INSERT #2) to the existing TS Bases to facilitate adoption of the TSTF while retaining the existing NUREG TS Surveillance Frequency TS Bases for licensees not choosing to adopt TSTF-425. The TSTF-425 TS Bases INSERT #2 states:
The Surveillance Frequency is based on operating experience, equipment reliability, and plant risk and is controlled under the Surveillance Frequency Control Program.
Several licensees requesting license amendments to adopt TSTF-425 have identified a need to deviate from this statement because it only applies to Frequencies that have been changed in accordance with the Surveillance Frequency Control Program (SFCP) and does not apply to Frequencies that are relocated but not changed.
The NRC staff agrees that the TSTF-425 TS Bases insert applies only to relocated SFs that are subsequently evaluated and changed in accordance with the SFCP, and that the current insert does not apply to SFs relocated to the SFCP but remain unchanged. For SFs relocated to the SFCP but not subsequently changed in accordance with the program, the existing TS Bases description remains valid Bases for these SFs.
One option to address this concern for those instances where the licensee used TSTF-425 Insert 2, is to modify the wording used in the application as follows:
"The Surveillance Frequency is controlled under the Surveillance Frequency Control Program" Page 1
ATTACHMENT Response to Request for Additional Information In addition, the following statement should be included regarding SF Bases relocated to the SFCP:
"The existing Bases information describing the basis for the SUlVeillance Frequency will be relocated to the licensee-controlled SUlVeillance Frequency Control Program. /I It should be noted that only the Bases for the SF can be relocated to the SFCP. The Bases for the TS Surveillance will remain in the TS Bases and should not be relocated to the SFCP.
EGC*s applications for DNPS and QCNPS dated February 16, 2010, included the aforementioned deviations from the proposed language in TSTF-425, Revision 3. The NRC staff has reviewed the proposed deviation from TSTF-425 and requests that the licensee modify the application as described above, or develop an alternate resolution to the issue with Insert #2 described herein, and include appropriate justifications.
Response
The proposed changes described in References 1 and 2 requests NRC approval to relocate SFs to the SFCP. Upon implementation of the proposed changes, the existing TS Bases information describing the basis for the SF will be relocated to the licensee-controlled SFCP.
This will ensure that the information describing the bases for unchanged SFs is maintained.
As discussed in References 1 and 2, EGC proposed a variation from TSTF-425 that replaced text describing the basis for each SF relocated to the SFCP. This variation was necessary because, independent of whether SFs have been changed under the SFCP, the SFs are not, in all cases, based on operating experience, equipment reliability, and plant risk.
As required by proposed DNPS TS Section 5.5.15 and aCNPS TS Section 5.5.14, "Surveillance Frequency Control Program,1I subsequent changes to the SFs listed in the SFCP will be made in accordance with the NRC-endorsed methodology described in Nuclear Energy Institute (NEI) 04-10, IIRisk-lnformed Method for Control of Surveillance Frequencies," Revision 1.
NEI 04-10 provides the methodology to identify, assess, implement, and monitor proposed changes to SFs. NEI 04-10 identifies the need to address both quantitative and qualitative considerations when changing SFs. As discussed in Section 4.0, Step 7, qualitative considerations include vendor-specified maintenance frequency, test intervals specified in applicable industry codes and standards, impact on defense-in-depth protection, and the existence of alternate testing of structures, systems, and components (SSCs) affected by the change. These qualitative considerations provide examples of instances where SFs changed under the SFCP may not be based upon operating experience, equipment reliability, or plant risk.
In order to avoid future confusion regarding this issue, EGC will replace the TS Bases text insert proposed in References 1 and 2 (Le., liThe Frequency may be based on factors such as operating experience, equipment reliability, or plant risk, and is controlled under the Surveillance ll Frequency Control Program with a revised insert that reads 'The Surveillance Frequency is
)
controlled under the Surveillance Frequency Control Program." This change to the TS Bases text inserts will be made upon implementation of the proposed changes.
Page 2
ATTACHMENT Response to Request for Additional Information References
- 1. DNPS letter from J. L. Hansen (Exelon Generation Company, LLC) to U.S. NRC, "Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program (Adoption of TSTF-425, Revision 3),11 dated February 16, 2010 (ADAMS Accession No. ML100480330)
- 2. QCNPS letter from J. L. Hansen (Exelon Generation Company, LLC) to U.S. NRC, "Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program (Adoption of TSTF-425, Revision 3)," dated February 16, 2010 (ADAMS Accession No. ML100480339)
Page 3