MONTHYEARRNP-RA/21-0035, Duke Energy Progress, Inc - Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report2021-02-18018 February 2021 Duke Energy Progress, Inc - Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report RNP-RA/20-0234, Independent Spent Fuel Storage Installation, Registration of Use of Spent Fuel Casks2020-07-23023 July 2020 Independent Spent Fuel Storage Installation, Registration of Use of Spent Fuel Casks RNP-RA/20-0199, Registration of Use of Spent Fuel Casks2020-06-25025 June 2020 Registration of Use of Spent Fuel Casks RNP-RA/18-0063, Request for Extension of Due Date for Seismic Probabilistic Risk Assessment Submittal2018-11-29029 November 2018 Request for Extension of Due Date for Seismic Probabilistic Risk Assessment Submittal RNP-RA/18-0060, Transmittal of Core Operating Limits Report2018-10-17017 October 2018 Transmittal of Core Operating Limits Report RNP-RA/18-0050, Response to Supplemental Request for Additional Information Regarding License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use of Load Tap Change2018-08-0101 August 2018 Response to Supplemental Request for Additional Information Regarding License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use of Load Tap Change RNP-RA/18-0044, Supplement to License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use of Load Tap Changers in the Automatic Mode of Operation on the Startup Transform2018-07-11011 July 2018 Supplement to License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use of Load Tap Changers in the Automatic Mode of Operation on the Startup Transformers RNP-RA/18-0039, Transmittal of Emergency Procedure Revisions and 10 CFR 50.54(q) Summary of Analysis2018-06-27027 June 2018 Transmittal of Emergency Procedure Revisions and 10 CFR 50.54(q) Summary of Analysis RNP-RA/18-0041, Independent Spent Fuel Storage Installation - Register as User for Cask2018-06-13013 June 2018 Independent Spent Fuel Storage Installation - Register as User for Cask RNP-RA/18-0036, Response to Request for Additional Information (RAI) Regarding Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use ...2018-05-16016 May 2018 Response to Request for Additional Information (RAI) Regarding Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use ... RNP-RA/18-0029, Submittal of 2017 Annual Radiological Environmental Operating Report2018-05-0808 May 2018 Submittal of 2017 Annual Radiological Environmental Operating Report RNP-RA/18-0031, (Hbrsep), Unit 2 - 2017 Annual Radioactive Effluent Release Report and Offsite Dose Calculation Manual, Revision 352018-04-23023 April 2018 (Hbrsep), Unit 2 - 2017 Annual Radioactive Effluent Release Report and Offsite Dose Calculation Manual, Revision 35 RNP-RA/18-0015, Application for Technical Specifications Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequently Requirements to a Licensee Controlled Program2018-04-16016 April 2018 Application for Technical Specifications Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequently Requirements to a Licensee Controlled Program RNP-RA/18-0024, Report of Changes Pursuant to 10 CFR 50.59(d)(2)2018-04-0202 April 2018 Report of Changes Pursuant to 10 CFR 50.59(d)(2) RNP-RA/18-0020, Notification of Change in Licensed Operator Status2018-02-20020 February 2018 Notification of Change in Licensed Operator Status RNP-RA/18-0003, Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report2018-01-23023 January 2018 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report RNP-RA/17-0085, Request for Additional Information Regarding Application to Revise Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2018-01-0808 January 2018 Request for Additional Information Regarding Application to Revise Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/17-0086, Transmittal of Emergency Procedure Revision and 10 CFR 50.54(q) Summary of Analyses2017-12-14014 December 2017 Transmittal of Emergency Procedure Revision and 10 CFR 50.54(q) Summary of Analyses RNP-RA/17-0081, Submittal of Change in Licensed Operators Medical Status2017-12-11011 December 2017 Submittal of Change in Licensed Operators Medical Status RNP-RA/17-0079, Operator License Renewal Application2017-12-0707 December 2017 Operator License Renewal Application RNP-RA/17-0071, Independent Spent Fuel Storage Installation (ISFSI) Registration for Use of General License Spent Fuel Casks2017-10-19019 October 2017 Independent Spent Fuel Storage Installation (ISFSI) Registration for Use of General License Spent Fuel Casks RNP-RA/17-0068, Response to NRC Request for Additional Information Related to License Amendment Request Regarding Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2017-09-28028 September 2017 Response to NRC Request for Additional Information Related to License Amendment Request Regarding Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/17-0037, License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specifications 3.8.1, AC Sources-Operating and the Use of Load Tap Changers in the Automatic Mode of Operation on the Startup Transformers2017-09-27027 September 2017 License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specifications 3.8.1, AC Sources-Operating and the Use of Load Tap Changers in the Automatic Mode of Operation on the Startup Transformers RNP-RA/17-0043, Relief Request (RR)-12 for Relief from Volumetric/Surface Examination Frequency Requirements of ASME Code Case N-729-42017-09-22022 September 2017 Relief Request (RR)-12 for Relief from Volumetric/Surface Examination Frequency Requirements of ASME Code Case N-729-4 RNP-RA/17-0065, Refueling Outage 30 Steam Generator Tube Inspection Report2017-09-18018 September 2017 Refueling Outage 30 Steam Generator Tube Inspection Report RNP-RA/17-0060, Notification of Change in Licensed Operator Status2017-08-10010 August 2017 Notification of Change in Licensed Operator Status RNP-RA/17-0058, Notification of Change in Licensed Operator Status2017-08-0303 August 2017 Notification of Change in Licensed Operator Status RNP-RA/17-0055, Transmittal of Core Operating Limits Report for Cycle 312017-07-26026 July 2017 Transmittal of Core Operating Limits Report for Cycle 31 RNP-RA/17-0042, Submittal of the PWROG-14048-P, Revision 1, to Satisfy the Regulatory Commitment Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals2017-06-29029 June 2017 Submittal of the PWROG-14048-P, Revision 1, to Satisfy the Regulatory Commitment Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals RNP-RA/17-0051, Submittal of Nine Day Inservice Inspection Summary Report2017-06-29029 June 2017 Submittal of Nine Day Inservice Inspection Summary Report RNP-RA/17-0041, Transmittal of Technical Specifications Bases Revisions2017-05-23023 May 2017 Transmittal of Technical Specifications Bases Revisions RNP-RA/17-0038, (Hbrsep), Unit No. 2 - 2016 Annual Radiological Environmental Operating Report2017-05-0909 May 2017 (Hbrsep), Unit No. 2 - 2016 Annual Radiological Environmental Operating Report RNP-RA/17-0034, Modification of Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles (MF9544)2017-05-0202 May 2017 Modification of Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles (MF9544) RNP-RA/17-0036, (Hbrsep), Unit No. 2 - 2016 Annual Radioactive Effluent Release Report and Offsite Dose Calculation Manual, Current Revision 342017-04-25025 April 2017 (Hbrsep), Unit No. 2 - 2016 Annual Radioactive Effluent Release Report and Offsite Dose Calculation Manual, Current Revision 34 RNP-RA/17-0031, Provides Additional Information Regarding License Amendment Request to Adopt Technical Specifications Task Force (TSTF) Traveler 522, Revision 02017-04-20020 April 2017 Provides Additional Information Regarding License Amendment Request to Adopt Technical Specifications Task Force (TSTF) Traveler 522, Revision 0 RNP-RA/17-0033, Flood Hazard Mitigating Strategies Assessment (MSA) Report Submittal2017-04-12012 April 2017 Flood Hazard Mitigating Strategies Assessment (MSA) Report Submittal RNP-RA/17-0014, Resubmittal of Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2017-04-0303 April 2017 Resubmittal of Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/17-0028, Submittal of Engineering Calculation in Support of a Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2017-04-0303 April 2017 Submittal of Engineering Calculation in Support of a Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/17-0021, Transmittal of Core Operating Limits Report2017-03-13013 March 2017 Transmittal of Core Operating Limits Report RNP-RA/17-0019, Supplemental Submittal to Correct Marked Up Technical Specifications (TS) Pages Transmitted with Application for Technical Specification Task Force (TSTF)-339, Relocate TS Parameters to the COLR Consistent with WCAP-14483, Revision 22017-03-0808 March 2017 Supplemental Submittal to Correct Marked Up Technical Specifications (TS) Pages Transmitted with Application for Technical Specification Task Force (TSTF)-339, Relocate TS Parameters to the COLR Consistent with WCAP-14483, Revision 2 RNP-RA/17-0015, Independent Spent Fuel Storage Installations - Letter Regarding Report of Changes Pursuant to 10 CFR 72.482017-02-22022 February 2017 Independent Spent Fuel Storage Installations - Letter Regarding Report of Changes Pursuant to 10 CFR 72.48 RNP-RA/17-0016, Independent Spent Fuel Storage Installation - Annual Radioactive Effluent Release Report2017-02-22022 February 2017 Independent Spent Fuel Storage Installation - Annual Radioactive Effluent Release Report RNP-RA/17-0015, H.B. Robinson Steam Electric Plant & ISFSIs - Report of Changes Pursuant to 10 CFR 72.482017-02-22022 February 2017 H.B. Robinson Steam Electric Plant & ISFSIs - Report of Changes Pursuant to 10 CFR 72.48 RNP-RA/16-0100, Response to Apparent Violation in NRC Inspection Report 05000261/2016404, EA-16-2272017-01-24024 January 2017 Response to Apparent Violation in NRC Inspection Report 05000261/2016404, EA-16-227 RNP-RA/16-0097, Transmittal Letter for Response to Inspection Report Temporary Instruction 2201/004, Inspection of Implementation of Interim Cyber Security Milestones 1-7, Inspection Report 05000261/20154052016-12-15015 December 2016 Transmittal Letter for Response to Inspection Report Temporary Instruction 2201/004, Inspection of Implementation of Interim Cyber Security Milestones 1-7, Inspection Report 05000261/2015405 RNP-RA/16-0089, Request for Withdrawal of License Amendment Request for Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2016-11-10010 November 2016 Request for Withdrawal of License Amendment Request for Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/16-0090, Notification of Rescheduled Date for 2017 Emergency Preparedness Graded Exercise2016-11-10010 November 2016 Notification of Rescheduled Date for 2017 Emergency Preparedness Graded Exercise RNP-RA/16-0087, Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report for Inoperable High Range Containment Area Radiation Monitors2016-10-31031 October 2016 Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report for Inoperable High Range Containment Area Radiation Monitors RNP-RA/16-0078, Technical Specifications Section 5.6.6, Post Accident Monitoring Instrumentation Report for Inoperable High Range Containment Area Radiation Monitors2016-10-0505 October 2016 Technical Specifications Section 5.6.6, Post Accident Monitoring Instrumentation Report for Inoperable High Range Containment Area Radiation Monitors RNP-RA/16-0079, Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association Standard 805, Performance-Based Standard for Light Water Reactor Electric Generating Plants.2016-10-0505 October 2016 Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association Standard 805, Performance-Based Standard for Light Water Reactor Electric Generating Plants. 2021-02-18
[Table view] |
Text
10 CFR 50.90 Progress Energy ,.
Serial: RNP-RA/08-0031 JUN 24 2008 United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261/LICENSE NO. DPR-23 RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION AND WITHDRAWAL OF PROPOSED TECHNICAL SPECIFICATIONS CHANGES TO SECTION 3.3.1, REACTOR PROTECTION SYSTEM INSTRUMENTATION Ladies and Gentlemen:
In a letter dated November 29, 2007, Carolina Power and Light Company, also known as Progress Energy Carolinas, Inc. (PEC), requested NRC review and approval of changes to modify the Technical Specifications (TS) requirements related to the interlock for the turbine trip input to the reactor protection system for H. B. Robinson Steam Electric Plant (HBRSEP),
Unit No. 2. An NRC request for additional information (RAI) pertaining to this amendment request was received by electronic mail transmission dated January 15, 2008.
In recent determinations pertaining to the upcoming refueling outage, it has been concluded that the proposed modification to the reactor protection system instrumentation will not be pursued.
Therefore, this license amendment request is hereby withdrawn. The response to the RAI pertaining to this amendment request is provided to facilitate possible re-submittal of this license amendment request at a future date. A nuclear condition report (NCR) has been initiated in the HBRSEP, Unit No. 2, corrective action program that describes the circumstances associated with the withdrawal of this amendment request. The need to withdraw this amendment request was precipitated by the determination during the outage planning process that the upcoming refueling outage scope needed to be reduced.
Attachment I provides an Affirmation in accordance with the provisions of 10 CFR 50.30(b).
Attachment II provides the response to the NRC RAI for this license amendment request.
In accordance with 10 CFR 50.91, a copy of this application is being provided to the State of South Carolina.
Progress Energy Carolinas, Inc. X o.
Robinson Nuclear Plant 3581 West Entrance Road Hartsville, SC 29550
United States Nuclear Regulatory Commission Serial: RNP-RA/08-0031 Page 2 of 2 If you have any questions concerning this matter, please contact Mr. Curt Castell at (843) 857-1626.
Sincerely, C. T. Baucom Manager - Support Services - Nuclear CTB/cac Attachments: I. Affirmation II. Response to NRC Request for Additional Information Related to Proposed Technical Specifications Changes to Section 3.3.1, Reactor Protection System Instrumentation c: S. E. Jenkins, Manager, Infectious and Radioactive Waste Management Section (SC)
A. Gantt, Chief, Bureau of Radiological Health (SC)
L. A. Reyes, NRC, Region II M. G. Vaaler, NRC, NRR NRC Resident Inspector, HBRSEP Attorney General (SC)
United States Nuclear Regulatory Commission Attachment I to Serial: RNP-RA/08-0031 Page 1 of 1 AFFIRMATION The information contained in letter RNP-RA/08-0031 is true and correct to the best of my information, knowledge and belief; and the sources of my information are officers, employees, contractors, and agents of Carolina Power and Light Company, also known as Progress Energy Carolinas, Inc. I declare under penalty of perjury that the foregoing is true and correct.
Executed On: (Qg (-2-3/?9 T. D. Walt Site Vice President, HBRSEP, Unit No. 2
United States Nuclear Regulatory Commission Attachment II to Serial: RNP-RA/08-0031 Page 1 of 2 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION RELATED TO PROPOSED TECHNICAL SPECIFICATIONS CHANGES TO SECTION 3.3.1. REACTOR PROTECTION SYSTEM INSTRUMENTATION The following response is provided for the NRC request for additional information (RAI) that was provided in an electronic mail transmission dated January 15, 2008:
NRC Request:
By letter dated November 29, 2007, Carolina Power & Light (the licensee), now doing business as Progress Energy Carolinas, Inc., submitted a license amendment request (LAR) to change the setpoint of the reactor trip on turbine trip interlock for the H. B. Robinson Steam Electric Plant, Unit No. 2 (HBR).
Page 8 of Attachment II to the LAR indicated that the licensee will implement modifications to the steam dump system identified in Westinghouse Report LTR-SCS-06-22, "H. B. Robinson Unit 2 Turbine Trip without Reactor Trip Transient from the P-8 Setpoint Analysis," which was included in the LAR as Attachment V.
The Westinghouse report indicated on page 10 that either "option 1" or "option 2" plant modifications could be used to satisfy the Three Mile Island (TMI) Action Item II.K.3.10 requirements concerning the probability of a small-break loss-of-coolant accident resulting from a stuck-open power-operated-relief-valve.
Please specify whether the identified "option 1" or "option 2" plant modifications will be selected to implement at HBR, and discuss the rationale for the selection. Also, discuss the plant modification plan and implementation program used to assure that HBR will include the required modifications when the plant is operated with the proposed interlock setpoint.
Response
Option 2 from the Westinghouse report has been selected. The Westinghouse report shows that Option 2 results in fewer fluctuations in plant parameters during the transient response, when compared with Option 1. Additionally, plant response was evaluated by testing Option 2 on the plant-specific simulator for H. B. Robinson Steam Electric Plant (HBRSEP), Unit No. 2, which supported the conclusions in the Westinghouse report. Therefore, Option 2 is the preferred option.
The Westinghouse report shows that either Option 1 or 2 can be used. Additionally, the acceptance criteria for this analysis, as documented in the Westinghouse report, is demonstration that the pressurizer power-operated relief valves are not expected to open during the transient conditions created by a turbine trip at approximately 40% power without a direct input to reactor trip.
United States Nuclear Regulatory Commission Attachment II to Serial: RNP-RA/08-0031 Page 2 of 2 Changes to the condenser steam dump control system can be made under licensee control in accordance with 10 CFR 50.59, provided that this and other applicable acceptance criteria for condenser steam dump system operation are met. Therefore, the statement that Option 2 has been chosen is not considered a commitment to implement Option 2, as described in the Westinghouse report. The commitment for plant modification, as stated in the November 29, 2007, license amendment request letter states, "This license amendment request includes a commitment to complete a plant modification in accordance with the engineering change process, which will be implemented to conduct the required plant changes."
Plant modification is required for implementation of changes associated with the turbine trip reactor protection system interlock. The plant modification includes changes to the reactor protection system wiring that will change the turbine trip reactor protection function interlock from the P-7 permissive circuitry to the P-8 permissive circuitry. The plant modification also includes changes to the condenser steam dump control system consistent with those identified in the Westinghouse report.
The plant modification requirements are documented in Engineering Change (EC) 63785. The modification includes the installation requirements and procedure updates that will implement the required interlock and control system changes. The reactor protection system interlock changes involve moving and connecting wires within the reactor protection system. The condenser steam dump control system changes involve changes to calibration procedures that are required to be performed in accordance with the installation instructions for the modification.
Option 2 from the Westinghouse report provides the proposed condenser steam dump system control settings for the plant trip controller proportional gain, the plant trip controller trip-open setpoints for Bank 1 and Bank 2, and the sudden loss of load bistables. These settings will be established and controlled in accordance with the calibration procedure changes described in EC 63785. The procedure controls for these settings remain consistent with the current requirements for maintaining the condenser steam dump control system settings, including the calibration procedure being subject to the requirements of 10 CFR 50.59.
Procedure EGR-NGGC-0005, "Engineering Change," contains explicit instructions for modification turnover to operations. The turnover section of EC 63785 states that the required work tickets shall be in the "Finished" status and that the required documents are updated.
Therefore, the modification requirements for EC 63785 establish the necessary steps and conditions that ensure the required modifications will be completed prior to plant operation with the proposed interlock change for the turbine trip.