MONTHYEARPY-CEI-NRR-2427, Application for Amend to License NPF-58,deleting License Condition 2.C.10 Re Controls Over Containment Air Locks During Plant Outages & Clarifying License Condition 2.F Re Reporting Requirements of TS & EPP Violations1999-09-14014 September 1999 Application for Amend to License NPF-58,deleting License Condition 2.C.10 Re Controls Over Containment Air Locks During Plant Outages & Clarifying License Condition 2.F Re Reporting Requirements of TS & EPP Violations PY-CEI-NRR-2406, Application for Amend to License NPF-58,eliminating Requirement in EPP to Sample Lake Erie Sediment in Perry & Eastlake Plant Area for Corbicula.Summary & Description of Change Is Encl1999-09-0909 September 1999 Application for Amend to License NPF-58,eliminating Requirement in EPP to Sample Lake Erie Sediment in Perry & Eastlake Plant Area for Corbicula.Summary & Description of Change Is Encl PY-CEI-NRR-2430, Application for Amend to License NPF-58,revising Allowables Values for CST Low Water Level Limits from Greater than or Equal to 59,700 Gallons to Greater than or Equal to 90,300 Gallons1999-09-0909 September 1999 Application for Amend to License NPF-58,revising Allowables Values for CST Low Water Level Limits from Greater than or Equal to 59,700 Gallons to Greater than or Equal to 90,300 Gallons PY-CEI-NRR-2420, Application for Amend to License NPF-58,increasing Present 100% Authorized Rated Thermal Power Level of 3579 Megawatts Thermal to 3758 Megawatts Thermal.Proprietary SAR Encl. Proprietary SAR Withheld,Per 10CFR2.790(a)(4)1999-09-0909 September 1999 Application for Amend to License NPF-58,increasing Present 100% Authorized Rated Thermal Power Level of 3579 Megawatts Thermal to 3758 Megawatts Thermal.Proprietary SAR Encl. Proprietary SAR Withheld,Per 10CFR2.790(a)(4) PY-CEI-NRR-2418, Application for Amend to License NPF-58,incorporating Addl Option Into TS 3.9.1 Required Actions When Refueling Interlocks Are Inoperable1999-08-0404 August 1999 Application for Amend to License NPF-58,incorporating Addl Option Into TS 3.9.1 Required Actions When Refueling Interlocks Are Inoperable PY-CEI-NRR-2398, Application for Amend to License NPF-58,changing SRs as Identified to Support Implementation of 24-month Operating Cycle at Pnpp1999-06-17017 June 1999 Application for Amend to License NPF-58,changing SRs as Identified to Support Implementation of 24-month Operating Cycle at Pnpp ML20206F5971999-05-0505 May 1999 Application for Amend to License NPF-58,authorizing CEI to Possess Dl 13.74% Undivided Ownership Interest in Pnpp PY-CEI-NRR-2362, Application for Amend to License NPF-58,proposing Change in Plant USAR by Incorporating leak-off Line in RHR Sys, Which Will Significantly Reduce Collective Dose to Plant Operations Personnel.Annotated USAR Pages,Encl1999-03-17017 March 1999 Application for Amend to License NPF-58,proposing Change in Plant USAR by Incorporating leak-off Line in RHR Sys, Which Will Significantly Reduce Collective Dose to Plant Operations Personnel.Annotated USAR Pages,Encl PY-CEI-NRR-2373, Application for Amend to License NPF-58,correcting Typos Found in TS Table 3.3.6.1-11999-03-15015 March 1999 Application for Amend to License NPF-58,correcting Typos Found in TS Table 3.3.6.1-1 PY-CEI-NRR-2359, Suppl Application for Amend to License NPF-58,involving Rev of Main Steam Line Leakage Requirements & Elimination of Main Steam Isolation Valve Leakage Control Sys.Proprietary Calculations Encl.Proprietary Encls Withheld1999-01-18018 January 1999 Suppl Application for Amend to License NPF-58,involving Rev of Main Steam Line Leakage Requirements & Elimination of Main Steam Isolation Valve Leakage Control Sys.Proprietary Calculations Encl.Proprietary Encls Withheld PY-CEI-NRR-2352, Suppl to 980909 LAR to License NPF-58,improving Licensing & Design Basis for Isolation of Feedwater Penetrations, Including Sensitivity Study Performed to Examine Radiological Significance of Leakage Through FW Sys Cvs1999-01-0606 January 1999 Suppl to 980909 LAR to License NPF-58,improving Licensing & Design Basis for Isolation of Feedwater Penetrations, Including Sensitivity Study Performed to Examine Radiological Significance of Leakage Through FW Sys Cvs PY-CEI-NRR-2325, Application for Amend to License NPF-58,applying Addl Conservatism by Modifying MCPR Safety Limit Values,As Calculated by Ge.Proprietary Addl Info Re 1.09 Cycle Specific Slmcpr,Encl.Proprietary Info Withheld1998-10-27027 October 1998 Application for Amend to License NPF-58,applying Addl Conservatism by Modifying MCPR Safety Limit Values,As Calculated by Ge.Proprietary Addl Info Re 1.09 Cycle Specific Slmcpr,Encl.Proprietary Info Withheld PY-CEI-NRR-2322, Application for Amend to License NPF-58,stipulating That Water Leakage from Feedwater motor-operated CIVs Will Be Added Into Primary Coolant Sources Outside of Containment Program & Valves Need Not Be Included in Test Program1998-09-0909 September 1998 Application for Amend to License NPF-58,stipulating That Water Leakage from Feedwater motor-operated CIVs Will Be Added Into Primary Coolant Sources Outside of Containment Program & Valves Need Not Be Included in Test Program PY-CEI-NRR-2319, Application for Amend to License NPF-58,permitting EDG TS Action Completion Time of Up to 14 Days for Div 1 or 2 EDG & Allow Performance of EDG 24-hour TS SR Test in Modes 1 & 21998-09-0303 September 1998 Application for Amend to License NPF-58,permitting EDG TS Action Completion Time of Up to 14 Days for Div 1 or 2 EDG & Allow Performance of EDG 24-hour TS SR Test in Modes 1 & 2 PY-CEI-NRR-2298, Application for Amend to License NPF-58,increasing Present Div 3 DG Fuel Oil Level Requirements to Account for Rounding Error in Calculation & Unusable Vol Due to Vortex Formation at Eductor Suction Nozzles Located in Fuel Oil Storag1998-09-0303 September 1998 Application for Amend to License NPF-58,increasing Present Div 3 DG Fuel Oil Level Requirements to Account for Rounding Error in Calculation & Unusable Vol Due to Vortex Formation at Eductor Suction Nozzles Located in Fuel Oil Storage Tank PY-CEI-NRR-2300, Application for Amend to License NPF-58,allowing Blind Flange in Inclined Fuel Transfer Sys (Ifts) Containment Penetration to Be Removed While Primary Containment Is Required to Be Operable1998-08-31031 August 1998 Application for Amend to License NPF-58,allowing Blind Flange in Inclined Fuel Transfer Sys (Ifts) Containment Penetration to Be Removed While Primary Containment Is Required to Be Operable PY-CEI-NRR-2299, Supplemental Application for Amend to License NPF-58, Revising MSL Leakage Requirements & Eliminating Msli Valve Leakage Control Sys.Proprietary & non-proprietary Rev 1 to Calculation Psat 08401T.03,encl.Proprietary Info Withheld1998-07-22022 July 1998 Supplemental Application for Amend to License NPF-58, Revising MSL Leakage Requirements & Eliminating Msli Valve Leakage Control Sys.Proprietary & non-proprietary Rev 1 to Calculation Psat 08401T.03,encl.Proprietary Info Withheld ML20151P1891998-07-13013 July 1998 Application for Amend to License NPF-58,revising Safety Setpoint Requirements for Srv.Proprietary Info & Affidavit Are Contained in Attachment 5.Proprietary Info Withheld PY-CEI-NRR-2295, Application for Amend to License NPF-58,revising TS 3.1.7, Standby Liquid Control Sys to Increase Boron Concentration in Standby Liquid Control Sys for Cycle 8 Fuel Design & to Provide Margin for Future Cycles as Required1998-06-30030 June 1998 Application for Amend to License NPF-58,revising TS 3.1.7, Standby Liquid Control Sys to Increase Boron Concentration in Standby Liquid Control Sys for Cycle 8 Fuel Design & to Provide Margin for Future Cycles as Required ML20236H6931998-06-30030 June 1998 Application for Amend to License NPF-58,transferring Operating Authority for Pnpp from Ceic & Centerior Svc Co to New Operating Company Named Firstenergy Nuclear Operating Co.Marked Up License,Safety & Environ Assessments,Included PY-CEI-NRR-2245, Application for Amend to License NPF-58,revising TS 3.8.1, AC Sources - Operating, to Be Consistent W/Recommendations in GL 94-01, Removal of Accelerated Testing & Special Reporting Requirements for Edgs1997-12-23023 December 1997 Application for Amend to License NPF-58,revising TS 3.8.1, AC Sources - Operating, to Be Consistent W/Recommendations in GL 94-01, Removal of Accelerated Testing & Special Reporting Requirements for Edgs PY-CEI-NRR-2230, Application for Amend to License NPF-58,incorporating Temp Control Valves & Associated Bypass Lines Around Emergency Closed Cooling Sys Heat Exchangers1997-10-22022 October 1997 Application for Amend to License NPF-58,incorporating Temp Control Valves & Associated Bypass Lines Around Emergency Closed Cooling Sys Heat Exchangers PY-CEI-NRR-2207, Application for Amend to License NPF-58,revising TS 5.2.2.e, Organization-Unit Staff, by Removing Ref to NRC Policy Statement on Working Hours1997-09-0808 September 1997 Application for Amend to License NPF-58,revising TS 5.2.2.e, Organization-Unit Staff, by Removing Ref to NRC Policy Statement on Working Hours PY-CEI-NRR-2206, Application for Amend to License NPF-58,revising Pressure- Temp Limits,Per Reactor Vessel Matl Surveillance Program Requirements Contained in App H of 10CFR50.901997-08-28028 August 1997 Application for Amend to License NPF-58,revising Pressure- Temp Limits,Per Reactor Vessel Matl Surveillance Program Requirements Contained in App H of 10CFR50.90 ML20217F5751997-07-28028 July 1997 Application for Amends to Licenses DPR-66,NPF-73 & NPF-58, Authorizing Holders to Possess Beaver Valley Power Station, Unit 1 & Authorizes Duquesne Light to Use & Operate Beaver Valley Unit 1 in Accordance W/Procedures PY-CEI-NRR-2164, Application for Amend to License NPF-58,revising Existing Exception to LCO 3.0.4 as Applies to LCO 3.6.1.9 for MSIV Leakage Control Sys1997-05-0202 May 1997 Application for Amend to License NPF-58,revising Existing Exception to LCO 3.0.4 as Applies to LCO 3.6.1.9 for MSIV Leakage Control Sys PY-CEI-NRR-2165, Application for Amend to License NPF-58,revising Tech Specs Surveillance Requirement for MSIV Leakage Rate Acceptance Criteria1997-05-0202 May 1997 Application for Amend to License NPF-58,revising Tech Specs Surveillance Requirement for MSIV Leakage Rate Acceptance Criteria PY-CEI-NRR-2155, Application for Amend to License NPF-58,revising TS Surveillance Requirements 3.9.1.1 & 3.9.2.2,extending SR Frequency on Refueling Equipment & one-rod-out Interlocks1997-04-0909 April 1997 Application for Amend to License NPF-58,revising TS Surveillance Requirements 3.9.1.1 & 3.9.2.2,extending SR Frequency on Refueling Equipment & one-rod-out Interlocks PY-CEI-NRR-2133, Application for Amend to License NPF-58,requesting Implementation of App J,Option B,Performance-based Primary Containment Leakage Rate Testing Program for Type A,B & C Leak Rate Tests1997-01-31031 January 1997 Application for Amend to License NPF-58,requesting Implementation of App J,Option B,Performance-based Primary Containment Leakage Rate Testing Program for Type A,B & C Leak Rate Tests ML20132C7601996-12-13013 December 1996 Application for Amend to License NPF-58,authorizing Transfers of Control PY-CEI-NRR-2104, Application for Amend to License NPF-58,modifying MCPR Reactor Core Safety Limit Contained in TS 2.1.1.21996-10-24024 October 1996 Application for Amend to License NPF-58,modifying MCPR Reactor Core Safety Limit Contained in TS 2.1.1.2 ML20117E7821996-08-27027 August 1996 Application for Amend to License NPF-58,revising MSL Leakage Requirements & Eliminating MSIV Leakage Control Sys. Attachment 7 Provides Proprietary Dose Calculations. Attachment 7 Withheld PY-CEI-NRR-1999, Application for Amend to License NPF-58,revising Improved Tech Specs.Changes Either Administrative in Nature or Reflect Minor Technical Errors Discovered During Implementation Process1996-04-26026 April 1996 Application for Amend to License NPF-58,revising Improved Tech Specs.Changes Either Administrative in Nature or Reflect Minor Technical Errors Discovered During Implementation Process PY-CEI-NRR-2030, Application for Amend to License NPF-58 Re Drywell Personnel Air Lock Shield Door Analyses1996-02-27027 February 1996 Application for Amend to License NPF-58 Re Drywell Personnel Air Lock Shield Door Analyses PY-CEI-NRR-2027, Application for Amend to License NPF-58,changing TS to Reflect Mod of Leakage Rate Requirements for Main Steam Lines Until End of Operating Cycle 61996-02-17017 February 1996 Application for Amend to License NPF-58,changing TS to Reflect Mod of Leakage Rate Requirements for Main Steam Lines Until End of Operating Cycle 6 PY-CEI-NRR-2007, Application for Amend to License NPF-58,revising TS Requirements for Drywell Leak Rate Testing1996-01-16016 January 1996 Application for Amend to License NPF-58,revising TS Requirements for Drywell Leak Rate Testing PY-CEI-NRR-2013, Application for Amend to License NPF-58,requesting one-time Surveillance Interval Extension to Support Current Schedule for Refueling Outage 5,scheduled to Begin 9601271996-01-10010 January 1996 Application for Amend to License NPF-58,requesting one-time Surveillance Interval Extension to Support Current Schedule for Refueling Outage 5,scheduled to Begin 960127 ML20095L2181995-12-28028 December 1995 Suppl Application for License Transfer of 12.58% Ownership Interest in Addition to 17.42% Approved on 951220 PY-CEI-NRR-2004, Application for Amend to License NPF-58,revising License to Reflect License Transfer for Part of Oh Edison Co Ownership Interest in Pnpp Unit 1 to Wholly Owned Subsidiary,Oes Nuclear,Inc1995-11-22022 November 1995 Application for Amend to License NPF-58,revising License to Reflect License Transfer for Part of Oh Edison Co Ownership Interest in Pnpp Unit 1 to Wholly Owned Subsidiary,Oes Nuclear,Inc PY-CEI-NRR-1978, Application for Amend to License NPF-58,requesting Rev to TS for Onsite Power Distribution Sys:Ts 3/4.8.3.1, Distribution - Operating1995-11-0202 November 1995 Application for Amend to License NPF-58,requesting Rev to TS for Onsite Power Distribution Sys:Ts 3/4.8.3.1, Distribution - Operating PY-CEI-NRR-1995, Application for Amend to License NPF-58,revising TS Requirements for Handling Irradiated Fuel in Containment or Fuel Handling Bldg & Certain Specs Related to Performing Core Alterations1995-11-0202 November 1995 Application for Amend to License NPF-58,revising TS Requirements for Handling Irradiated Fuel in Containment or Fuel Handling Bldg & Certain Specs Related to Performing Core Alterations PY-CEI-NRR-1997, Application for Amend to License NPF-58,providing Suppl Info That Revises License to Reflect Proposed Merger of Operating Companies1995-11-0101 November 1995 Application for Amend to License NPF-58,providing Suppl Info That Revises License to Reflect Proposed Merger of Operating Companies PY-CEI-NRR-1969, Application for Amend to License NPF-58,revising Tech Specs Allowable Values & Trip Setpoints for Selected Plant Process Instrumentation Using Instrument Setpoint Methodology Discussed in Util (PY-CEI/NRR-1706L)1995-08-29029 August 1995 Application for Amend to License NPF-58,revising Tech Specs Allowable Values & Trip Setpoints for Selected Plant Process Instrumentation Using Instrument Setpoint Methodology Discussed in Util (PY-CEI/NRR-1706L) PY-CEI-NRR-1961, Application for Amends to Licenses NPF-58,reflecting One Time Extension of Performance Intervals for Certain TS Surveillance Requirements1995-06-30030 June 1995 Application for Amends to Licenses NPF-58,reflecting One Time Extension of Performance Intervals for Certain TS Surveillance Requirements PY-CEI-NRR-1954, Application for Amend to License NPF-58.Amend Would Allow one-time Extension of Performance Intervals for Certain Srs. Application Supplements Original Request1995-06-0909 June 1995 Application for Amend to License NPF-58.Amend Would Allow one-time Extension of Performance Intervals for Certain Srs. Application Supplements Original Request PY-CEI-NRR-1956, Application for Amend to License NPF-58,proposing Early Implementation of Control Rod Drive Scram Time Testing Consistent W/Requirements in Pnpp Improved TS LAR1995-06-0101 June 1995 Application for Amend to License NPF-58,proposing Early Implementation of Control Rod Drive Scram Time Testing Consistent W/Requirements in Pnpp Improved TS LAR PY-CEI-NRR-1944, Suppl Application for Amend to License NPF-58,App a Tss. Suppl Addresses Minor Discrepancies & Items Needing Clarification1995-05-0505 May 1995 Suppl Application for Amend to License NPF-58,App a Tss. Suppl Addresses Minor Discrepancies & Items Needing Clarification PY-CEI-NRR-1927, Application for Amend to License NPF-58 Re Removal of License Conditions for Tdi EDGs Specified by Paragraph 2.c & Defined in Attachment 2 to Operating License1995-04-28028 April 1995 Application for Amend to License NPF-58 Re Removal of License Conditions for Tdi EDGs Specified by Paragraph 2.c & Defined in Attachment 2 to Operating License PY-CEI-NRR-1655, Application for Amend to License NPF-58,adding New Programmatic Requirements Governing Radiological Effluents Into Administrative Controls Section of TS & Relocating Procedural Details of RETS to ODCM or Pcp,Per GL 89-011995-04-0303 April 1995 Application for Amend to License NPF-58,adding New Programmatic Requirements Governing Radiological Effluents Into Administrative Controls Section of TS & Relocating Procedural Details of RETS to ODCM or Pcp,Per GL 89-01 PY-CEI-NRR-1890, Application for Amend to License NPF-58 Re one-time Extension of Performance Intervals for Certain TS Surveillance Requirements1995-03-24024 March 1995 Application for Amend to License NPF-58 Re one-time Extension of Performance Intervals for Certain TS Surveillance Requirements 1999-09-09
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARPY-CEI-NRR-2427, Application for Amend to License NPF-58,deleting License Condition 2.C.10 Re Controls Over Containment Air Locks During Plant Outages & Clarifying License Condition 2.F Re Reporting Requirements of TS & EPP Violations1999-09-14014 September 1999 Application for Amend to License NPF-58,deleting License Condition 2.C.10 Re Controls Over Containment Air Locks During Plant Outages & Clarifying License Condition 2.F Re Reporting Requirements of TS & EPP Violations PY-CEI-NRR-2430, Application for Amend to License NPF-58,revising Allowables Values for CST Low Water Level Limits from Greater than or Equal to 59,700 Gallons to Greater than or Equal to 90,300 Gallons1999-09-0909 September 1999 Application for Amend to License NPF-58,revising Allowables Values for CST Low Water Level Limits from Greater than or Equal to 59,700 Gallons to Greater than or Equal to 90,300 Gallons PY-CEI-NRR-2406, Application for Amend to License NPF-58,eliminating Requirement in EPP to Sample Lake Erie Sediment in Perry & Eastlake Plant Area for Corbicula.Summary & Description of Change Is Encl1999-09-0909 September 1999 Application for Amend to License NPF-58,eliminating Requirement in EPP to Sample Lake Erie Sediment in Perry & Eastlake Plant Area for Corbicula.Summary & Description of Change Is Encl PY-CEI-NRR-2420, Application for Amend to License NPF-58,increasing Present 100% Authorized Rated Thermal Power Level of 3579 Megawatts Thermal to 3758 Megawatts Thermal.Proprietary SAR Encl. Proprietary SAR Withheld,Per 10CFR2.790(a)(4)1999-09-0909 September 1999 Application for Amend to License NPF-58,increasing Present 100% Authorized Rated Thermal Power Level of 3579 Megawatts Thermal to 3758 Megawatts Thermal.Proprietary SAR Encl. Proprietary SAR Withheld,Per 10CFR2.790(a)(4) PY-CEI-NRR-2418, Application for Amend to License NPF-58,incorporating Addl Option Into TS 3.9.1 Required Actions When Refueling Interlocks Are Inoperable1999-08-0404 August 1999 Application for Amend to License NPF-58,incorporating Addl Option Into TS 3.9.1 Required Actions When Refueling Interlocks Are Inoperable PY-CEI-NRR-2398, Application for Amend to License NPF-58,changing SRs as Identified to Support Implementation of 24-month Operating Cycle at Pnpp1999-06-17017 June 1999 Application for Amend to License NPF-58,changing SRs as Identified to Support Implementation of 24-month Operating Cycle at Pnpp ML20206F5971999-05-0505 May 1999 Application for Amend to License NPF-58,authorizing CEI to Possess Dl 13.74% Undivided Ownership Interest in Pnpp PY-CEI-NRR-2362, Application for Amend to License NPF-58,proposing Change in Plant USAR by Incorporating leak-off Line in RHR Sys, Which Will Significantly Reduce Collective Dose to Plant Operations Personnel.Annotated USAR Pages,Encl1999-03-17017 March 1999 Application for Amend to License NPF-58,proposing Change in Plant USAR by Incorporating leak-off Line in RHR Sys, Which Will Significantly Reduce Collective Dose to Plant Operations Personnel.Annotated USAR Pages,Encl PY-CEI-NRR-2373, Application for Amend to License NPF-58,correcting Typos Found in TS Table 3.3.6.1-11999-03-15015 March 1999 Application for Amend to License NPF-58,correcting Typos Found in TS Table 3.3.6.1-1 PY-CEI-NRR-2359, Suppl Application for Amend to License NPF-58,involving Rev of Main Steam Line Leakage Requirements & Elimination of Main Steam Isolation Valve Leakage Control Sys.Proprietary Calculations Encl.Proprietary Encls Withheld1999-01-18018 January 1999 Suppl Application for Amend to License NPF-58,involving Rev of Main Steam Line Leakage Requirements & Elimination of Main Steam Isolation Valve Leakage Control Sys.Proprietary Calculations Encl.Proprietary Encls Withheld PY-CEI-NRR-2352, Suppl to 980909 LAR to License NPF-58,improving Licensing & Design Basis for Isolation of Feedwater Penetrations, Including Sensitivity Study Performed to Examine Radiological Significance of Leakage Through FW Sys Cvs1999-01-0606 January 1999 Suppl to 980909 LAR to License NPF-58,improving Licensing & Design Basis for Isolation of Feedwater Penetrations, Including Sensitivity Study Performed to Examine Radiological Significance of Leakage Through FW Sys Cvs PY-CEI-NRR-2325, Application for Amend to License NPF-58,applying Addl Conservatism by Modifying MCPR Safety Limit Values,As Calculated by Ge.Proprietary Addl Info Re 1.09 Cycle Specific Slmcpr,Encl.Proprietary Info Withheld1998-10-27027 October 1998 Application for Amend to License NPF-58,applying Addl Conservatism by Modifying MCPR Safety Limit Values,As Calculated by Ge.Proprietary Addl Info Re 1.09 Cycle Specific Slmcpr,Encl.Proprietary Info Withheld PY-CEI-NRR-2322, Application for Amend to License NPF-58,stipulating That Water Leakage from Feedwater motor-operated CIVs Will Be Added Into Primary Coolant Sources Outside of Containment Program & Valves Need Not Be Included in Test Program1998-09-0909 September 1998 Application for Amend to License NPF-58,stipulating That Water Leakage from Feedwater motor-operated CIVs Will Be Added Into Primary Coolant Sources Outside of Containment Program & Valves Need Not Be Included in Test Program PY-CEI-NRR-2298, Application for Amend to License NPF-58,increasing Present Div 3 DG Fuel Oil Level Requirements to Account for Rounding Error in Calculation & Unusable Vol Due to Vortex Formation at Eductor Suction Nozzles Located in Fuel Oil Storag1998-09-0303 September 1998 Application for Amend to License NPF-58,increasing Present Div 3 DG Fuel Oil Level Requirements to Account for Rounding Error in Calculation & Unusable Vol Due to Vortex Formation at Eductor Suction Nozzles Located in Fuel Oil Storage Tank PY-CEI-NRR-2319, Application for Amend to License NPF-58,permitting EDG TS Action Completion Time of Up to 14 Days for Div 1 or 2 EDG & Allow Performance of EDG 24-hour TS SR Test in Modes 1 & 21998-09-0303 September 1998 Application for Amend to License NPF-58,permitting EDG TS Action Completion Time of Up to 14 Days for Div 1 or 2 EDG & Allow Performance of EDG 24-hour TS SR Test in Modes 1 & 2 PY-CEI-NRR-2300, Application for Amend to License NPF-58,allowing Blind Flange in Inclined Fuel Transfer Sys (Ifts) Containment Penetration to Be Removed While Primary Containment Is Required to Be Operable1998-08-31031 August 1998 Application for Amend to License NPF-58,allowing Blind Flange in Inclined Fuel Transfer Sys (Ifts) Containment Penetration to Be Removed While Primary Containment Is Required to Be Operable PY-CEI-NRR-2299, Supplemental Application for Amend to License NPF-58, Revising MSL Leakage Requirements & Eliminating Msli Valve Leakage Control Sys.Proprietary & non-proprietary Rev 1 to Calculation Psat 08401T.03,encl.Proprietary Info Withheld1998-07-22022 July 1998 Supplemental Application for Amend to License NPF-58, Revising MSL Leakage Requirements & Eliminating Msli Valve Leakage Control Sys.Proprietary & non-proprietary Rev 1 to Calculation Psat 08401T.03,encl.Proprietary Info Withheld ML20151P1891998-07-13013 July 1998 Application for Amend to License NPF-58,revising Safety Setpoint Requirements for Srv.Proprietary Info & Affidavit Are Contained in Attachment 5.Proprietary Info Withheld PY-CEI-NRR-2295, Application for Amend to License NPF-58,revising TS 3.1.7, Standby Liquid Control Sys to Increase Boron Concentration in Standby Liquid Control Sys for Cycle 8 Fuel Design & to Provide Margin for Future Cycles as Required1998-06-30030 June 1998 Application for Amend to License NPF-58,revising TS 3.1.7, Standby Liquid Control Sys to Increase Boron Concentration in Standby Liquid Control Sys for Cycle 8 Fuel Design & to Provide Margin for Future Cycles as Required ML20236H6931998-06-30030 June 1998 Application for Amend to License NPF-58,transferring Operating Authority for Pnpp from Ceic & Centerior Svc Co to New Operating Company Named Firstenergy Nuclear Operating Co.Marked Up License,Safety & Environ Assessments,Included PY-CEI-NRR-2245, Application for Amend to License NPF-58,revising TS 3.8.1, AC Sources - Operating, to Be Consistent W/Recommendations in GL 94-01, Removal of Accelerated Testing & Special Reporting Requirements for Edgs1997-12-23023 December 1997 Application for Amend to License NPF-58,revising TS 3.8.1, AC Sources - Operating, to Be Consistent W/Recommendations in GL 94-01, Removal of Accelerated Testing & Special Reporting Requirements for Edgs PY-CEI-NRR-2230, Application for Amend to License NPF-58,incorporating Temp Control Valves & Associated Bypass Lines Around Emergency Closed Cooling Sys Heat Exchangers1997-10-22022 October 1997 Application for Amend to License NPF-58,incorporating Temp Control Valves & Associated Bypass Lines Around Emergency Closed Cooling Sys Heat Exchangers PY-CEI-NRR-2207, Application for Amend to License NPF-58,revising TS 5.2.2.e, Organization-Unit Staff, by Removing Ref to NRC Policy Statement on Working Hours1997-09-0808 September 1997 Application for Amend to License NPF-58,revising TS 5.2.2.e, Organization-Unit Staff, by Removing Ref to NRC Policy Statement on Working Hours PY-CEI-NRR-2206, Application for Amend to License NPF-58,revising Pressure- Temp Limits,Per Reactor Vessel Matl Surveillance Program Requirements Contained in App H of 10CFR50.901997-08-28028 August 1997 Application for Amend to License NPF-58,revising Pressure- Temp Limits,Per Reactor Vessel Matl Surveillance Program Requirements Contained in App H of 10CFR50.90 ML20217F5751997-07-28028 July 1997 Application for Amends to Licenses DPR-66,NPF-73 & NPF-58, Authorizing Holders to Possess Beaver Valley Power Station, Unit 1 & Authorizes Duquesne Light to Use & Operate Beaver Valley Unit 1 in Accordance W/Procedures PY-CEI-NRR-2164, Application for Amend to License NPF-58,revising Existing Exception to LCO 3.0.4 as Applies to LCO 3.6.1.9 for MSIV Leakage Control Sys1997-05-0202 May 1997 Application for Amend to License NPF-58,revising Existing Exception to LCO 3.0.4 as Applies to LCO 3.6.1.9 for MSIV Leakage Control Sys PY-CEI-NRR-2165, Application for Amend to License NPF-58,revising Tech Specs Surveillance Requirement for MSIV Leakage Rate Acceptance Criteria1997-05-0202 May 1997 Application for Amend to License NPF-58,revising Tech Specs Surveillance Requirement for MSIV Leakage Rate Acceptance Criteria PY-CEI-NRR-2155, Application for Amend to License NPF-58,revising TS Surveillance Requirements 3.9.1.1 & 3.9.2.2,extending SR Frequency on Refueling Equipment & one-rod-out Interlocks1997-04-0909 April 1997 Application for Amend to License NPF-58,revising TS Surveillance Requirements 3.9.1.1 & 3.9.2.2,extending SR Frequency on Refueling Equipment & one-rod-out Interlocks PY-CEI-NRR-2133, Application for Amend to License NPF-58,requesting Implementation of App J,Option B,Performance-based Primary Containment Leakage Rate Testing Program for Type A,B & C Leak Rate Tests1997-01-31031 January 1997 Application for Amend to License NPF-58,requesting Implementation of App J,Option B,Performance-based Primary Containment Leakage Rate Testing Program for Type A,B & C Leak Rate Tests ML20132C7601996-12-13013 December 1996 Application for Amend to License NPF-58,authorizing Transfers of Control PY-CEI-NRR-2104, Application for Amend to License NPF-58,modifying MCPR Reactor Core Safety Limit Contained in TS 2.1.1.21996-10-24024 October 1996 Application for Amend to License NPF-58,modifying MCPR Reactor Core Safety Limit Contained in TS 2.1.1.2 ML20117E7821996-08-27027 August 1996 Application for Amend to License NPF-58,revising MSL Leakage Requirements & Eliminating MSIV Leakage Control Sys. Attachment 7 Provides Proprietary Dose Calculations. Attachment 7 Withheld PY-CEI-NRR-1999, Application for Amend to License NPF-58,revising Improved Tech Specs.Changes Either Administrative in Nature or Reflect Minor Technical Errors Discovered During Implementation Process1996-04-26026 April 1996 Application for Amend to License NPF-58,revising Improved Tech Specs.Changes Either Administrative in Nature or Reflect Minor Technical Errors Discovered During Implementation Process PY-CEI-NRR-2030, Application for Amend to License NPF-58 Re Drywell Personnel Air Lock Shield Door Analyses1996-02-27027 February 1996 Application for Amend to License NPF-58 Re Drywell Personnel Air Lock Shield Door Analyses PY-CEI-NRR-2027, Application for Amend to License NPF-58,changing TS to Reflect Mod of Leakage Rate Requirements for Main Steam Lines Until End of Operating Cycle 61996-02-17017 February 1996 Application for Amend to License NPF-58,changing TS to Reflect Mod of Leakage Rate Requirements for Main Steam Lines Until End of Operating Cycle 6 PY-CEI-NRR-2007, Application for Amend to License NPF-58,revising TS Requirements for Drywell Leak Rate Testing1996-01-16016 January 1996 Application for Amend to License NPF-58,revising TS Requirements for Drywell Leak Rate Testing PY-CEI-NRR-2013, Application for Amend to License NPF-58,requesting one-time Surveillance Interval Extension to Support Current Schedule for Refueling Outage 5,scheduled to Begin 9601271996-01-10010 January 1996 Application for Amend to License NPF-58,requesting one-time Surveillance Interval Extension to Support Current Schedule for Refueling Outage 5,scheduled to Begin 960127 ML20095L2181995-12-28028 December 1995 Suppl Application for License Transfer of 12.58% Ownership Interest in Addition to 17.42% Approved on 951220 PY-CEI-NRR-2004, Application for Amend to License NPF-58,revising License to Reflect License Transfer for Part of Oh Edison Co Ownership Interest in Pnpp Unit 1 to Wholly Owned Subsidiary,Oes Nuclear,Inc1995-11-22022 November 1995 Application for Amend to License NPF-58,revising License to Reflect License Transfer for Part of Oh Edison Co Ownership Interest in Pnpp Unit 1 to Wholly Owned Subsidiary,Oes Nuclear,Inc PY-CEI-NRR-1978, Application for Amend to License NPF-58,requesting Rev to TS for Onsite Power Distribution Sys:Ts 3/4.8.3.1, Distribution - Operating1995-11-0202 November 1995 Application for Amend to License NPF-58,requesting Rev to TS for Onsite Power Distribution Sys:Ts 3/4.8.3.1, Distribution - Operating PY-CEI-NRR-1995, Application for Amend to License NPF-58,revising TS Requirements for Handling Irradiated Fuel in Containment or Fuel Handling Bldg & Certain Specs Related to Performing Core Alterations1995-11-0202 November 1995 Application for Amend to License NPF-58,revising TS Requirements for Handling Irradiated Fuel in Containment or Fuel Handling Bldg & Certain Specs Related to Performing Core Alterations PY-CEI-NRR-1997, Application for Amend to License NPF-58,providing Suppl Info That Revises License to Reflect Proposed Merger of Operating Companies1995-11-0101 November 1995 Application for Amend to License NPF-58,providing Suppl Info That Revises License to Reflect Proposed Merger of Operating Companies PY-CEI-NRR-1969, Application for Amend to License NPF-58,revising Tech Specs Allowable Values & Trip Setpoints for Selected Plant Process Instrumentation Using Instrument Setpoint Methodology Discussed in Util (PY-CEI/NRR-1706L)1995-08-29029 August 1995 Application for Amend to License NPF-58,revising Tech Specs Allowable Values & Trip Setpoints for Selected Plant Process Instrumentation Using Instrument Setpoint Methodology Discussed in Util (PY-CEI/NRR-1706L) PY-CEI-NRR-1961, Application for Amends to Licenses NPF-58,reflecting One Time Extension of Performance Intervals for Certain TS Surveillance Requirements1995-06-30030 June 1995 Application for Amends to Licenses NPF-58,reflecting One Time Extension of Performance Intervals for Certain TS Surveillance Requirements PY-CEI-NRR-1954, Application for Amend to License NPF-58.Amend Would Allow one-time Extension of Performance Intervals for Certain Srs. Application Supplements Original Request1995-06-0909 June 1995 Application for Amend to License NPF-58.Amend Would Allow one-time Extension of Performance Intervals for Certain Srs. Application Supplements Original Request PY-CEI-NRR-1956, Application for Amend to License NPF-58,proposing Early Implementation of Control Rod Drive Scram Time Testing Consistent W/Requirements in Pnpp Improved TS LAR1995-06-0101 June 1995 Application for Amend to License NPF-58,proposing Early Implementation of Control Rod Drive Scram Time Testing Consistent W/Requirements in Pnpp Improved TS LAR PY-CEI-NRR-1944, Suppl Application for Amend to License NPF-58,App a Tss. Suppl Addresses Minor Discrepancies & Items Needing Clarification1995-05-0505 May 1995 Suppl Application for Amend to License NPF-58,App a Tss. Suppl Addresses Minor Discrepancies & Items Needing Clarification PY-CEI-NRR-1927, Application for Amend to License NPF-58 Re Removal of License Conditions for Tdi EDGs Specified by Paragraph 2.c & Defined in Attachment 2 to Operating License1995-04-28028 April 1995 Application for Amend to License NPF-58 Re Removal of License Conditions for Tdi EDGs Specified by Paragraph 2.c & Defined in Attachment 2 to Operating License PY-CEI-NRR-1655, Application for Amend to License NPF-58,adding New Programmatic Requirements Governing Radiological Effluents Into Administrative Controls Section of TS & Relocating Procedural Details of RETS to ODCM or Pcp,Per GL 89-011995-04-0303 April 1995 Application for Amend to License NPF-58,adding New Programmatic Requirements Governing Radiological Effluents Into Administrative Controls Section of TS & Relocating Procedural Details of RETS to ODCM or Pcp,Per GL 89-01 PY-CEI-NRR-1890, Application for Amend to License NPF-58 Re one-time Extension of Performance Intervals for Certain TS Surveillance Requirements1995-03-24024 March 1995 Application for Amend to License NPF-58 Re one-time Extension of Performance Intervals for Certain TS Surveillance Requirements 1999-09-09
[Table view] |
Text
'
C~~NTERIOR Q ENERGY 1
l PERRY NUCLEAR POWER PLANT Maii /ddress: Donald C. Shelton 10 ER ROA SENIOR VICE PRESIDENT gg, R O 10 44081 E OO NUCLEAR (216) 259-3737 January 10, 1996 l PY-CEI/NRR-2013L 6 United States Nuclear Regulatory Commission Document Control Desk Vashington, D.C. 20555 Perry Nuclear Power Plant Docket No. 50-440 License Amendment Request: Surveillance Test Interval Extension Request - Emergency Change Gentlemen:
Enclosed please find an application for a change to the Perry Nuclear Power Plant (PNPP) Unit 1 Technical Specifications, reflecting a one-time extension of the performance intervals for certain Technical Specification Surveillance Requirements (SRs). This application supplements License Amendment 75, issued on November 29, 1995 in response l to the requests submitted by letter on March 24, 1995 (PY-CEI/NRR-1890L), !
and supplemented on June 9, 1995 (PY-CEI/NRR1954L), and on June 30, 1995 l (PY-CEI/NRR-1961L). This request addresses changes that were discussed j in the previous submittals, but not included in the marked-up Technical Specification pages submitted in the application for Amendment 75.
As with the previous requests for surveillance interval extension, the proposed change is requested on a one-time basis only,.to support the current schedule for Refueling Outage 5 (RF0-5), presently scheduled to begin January 27, 1996. The existing Technical Specifications, including the recently received Amendment 75, would require a plant shutdown six days prior to the end of the current fuel cycle solely to perform surveillances. Such a plant shutdown would cause an unnecessary outage extension. In addition, the proposed interval extensions that extend into RFO-5 are necessary to maintain the " defense in depth" and critical path of the outage as it is presently planned.
1 Attachment 1 provides a Summary, Statement of Emergency Circumstances, '
Safety Analyses, Description of the Proposed Technical Specification Changes, and the Environmental Consideration. Attachments 2 and 3 provide a marked-up copy of the affected Technical Specification pages and the Significant Hazards Consideration, respectively. To justify the extensions, the request incorporates plant specific data and test history to demonstrate the reliability of the affected instrumentation.
9601170078 960110 PDR ADOCK 05000440 P PDR opeeng co-pe es 4 Cteseed Eie&c oWa, To'ecaEd v s.
00n $8[
l l
1 PY-CEI/NRR-2013L l l
January 10, 1996 I Page 2 of 2 This request is being submitted under emergency circumstances. The first 1 of the surveillances vill go late on January 21, 1996, and would cause a plant shutdown shortly thereafter. These discrepancies were only recently determined to exist during the implementation of Amendment 75, and therefore there has not been sufficient time to permit the normal license change process to apply.
Issuance of the proposed changes is requested by January 20, 1996, so that the early plant shutdown can be averted.
If you have questions or require additional information, please contact Mr. James D. Kloosterman, Manager - Regulatory Affairs at (216) 280-5833.
Very truly our ,
d W b. Q S,e ffon DnalddIShelto DCS HLH:vh Attachment ec: Region III Administrator Resident Inspector Office NRC/NRR Project Manager State of Ohio l
l 1
l
l ,
V 4
k i
4 I, Richard D. Brandt, being duly sworn state that (1) I am General Manager, Perry Nuclear Power Plant Department of the Cleveland Electric Illuminating Company, (2) I am duly authorized to execute and file this certification on
- behalf of The Cleveland Electric Illuminating Company and Toledo Edison Company, and as the duly authorized agent for Duquesne Light Company, Ohio
. Edison Company, and Pennsylvania Power Company, and (3) the statements set i forth herein are true and correct to the best of my knowledge, information ;
2 i and belief.
I 4/[ ' a j Rich . Brandt i
4 rn to and subscribed before me, the /d4 day of ne ,
Swf%
I . g N l I
..# JANE E. HOTT Notary Ptclic, SWo of Ohio My Commlie, ion Exp;res FW 20.E000 (R000,00d M las Cour@)
i l
l
Attachmsnt 1 PY-CEI/NRR-2013L Page 1 of 2 1
SUMMARY
j The Perry Nuclear Power Plant (PNPP), Unit 1 Technical Specification (TS)
Surveillance Requirements (SRs) require surveillance testing to be conducted l nominally at refueling intervals but at least once every 18 months. Technical l Specification 4.0.2 allows a 25% extension of the surveillance interval to 22.5 i months, if required, to provide flexibility in cycle lengths.
Amendment 75 to the PNPP Operating License was issued November 29, 1995, in response to letters PY-CEI/NRR-1890L (March 24, 1995), PY-CEI/NRR-1954L (June 9, 1995) and PY-CEI/NRR-1961L (June 30, 1995). This Amendment granted numerous surveillance interval extensions in order to prevent a plant shutdown solely to perform surveillance testing. During the implementation of this Amendment it was determined that due to a discrepancy in the original amendment application, additional surveillance extensions were required.
The discrepancy consisted of items which were discussed in the previous submittals, but were not contained in the marked-up Technical Specification pages provided in the Amendment Request. These include the following:
- 1. SR 4.1.3.1.4.a.1 and 2 - These items were identified in the March 24, 1995 submittal with the justification presented in Enclosure 1 to that submittal. (See Enclosure 1)
- 2. SR 4.3.1.2, Table 4.3.1.1-1, Item 12 - This extension was discussed in the March 24, 1995 submittal with the justification presented in Enclosure 17 to that submittal. (See Enclosure 2)
- 3. SR 4.3.1.2, Table 4.3.1.1-1, Item 13 - This extension was discussed in the March 24, 1995 submittal with the justification presented in Enclosure 1 to that submittal. (See Enclosure 1)
- 4. SR 4.6.1.4.c.1 - This extension was discussed in the March 24, 1995 submittal with the justification presented in Enclosure 88 to that submittal. (See Enclosure 3)
- 5. SR 4.6.1.4.d.2 - This extension was discussed in the March 24, 1995 submittal with the justification presented in Enclosure 89 to that submittal. (See Enclosure 4)
These items were therefore justified in the previous submittals. T'e Significant Hazards Consideration for the March 24, 1995 submittal included the consideration of these extensions.
The first surveillance requirements become late on January 21, 1996, which is six days before the scheduled start of Refueling Outage 5 (RFO-5). If the requested extensions are not granted by this time the plant vould be required to shut down solely for the purpose of performing these tests. This vauld cause an unnecessary and costly extension to the outage. For this reason it is requested that this request be approved by January 20, 1996. Due to the timing involved the request vill have to be processed under emergency circumstances. The discussion of the reasons for emergency are given below.
Attechmtnt 1 PY-CEI/NRR-2013L Page 2 of 2 STATEMENT OF EMERGENCY CIRCUMSTANCES I 10 CFR 50.91(a)(5) requires that change requests submitted under emergency circumstances be explained. The need for this change request to extend the SRs became apparent on January 2, 1996 during a review of Amendment 75 implementation. The first Sh becomes late on January 21, 1996, and would require a plant shutdown by January 22, 1996 if not either performed or extended. Thus, there is not sufficient time for the change request to be processed under the normal review process. As discussed above, justification of these changes had been previously submitted, but appropriate markups were not included as part of the request for Amendment 75. It was the review of this Amendment that resulted in the discovery that additional extensions needed to be requested. The NRC staff permitted a 90 day implementation period from issuance of the Amendment (November 29, 1995). Thus the discovery of these discrepancies occurred during implementation reviews within the 90 day period between issuance and required implementation of the Amendment. This request has been submitted in a timely fashion since discovery that Amendment 75 did not include these required extensions. Therefore, the circumstances surrounding the submittal of this change request at this time could not have been avoided.
SAFETY ANALYSIS The Technical Specification SRs affected by the change are listed below. The justification for the extension of each SR is provided within the Enclosure noted.
TS SR 4.1.3.1.4.a.1 (Enclosure 1) ,
TS SR 4.1.3.1.4.a.2 (Enclosure 1) l TS SR 4.3.1.2, Table 4.3.1.1-1, Item 12 (Enclosure 2) f TS SR 4.3.1.2, Table 4.3.1.1-1, Item 13 (Enclosure 1) l TS SR 4.6.1.4.c.1 (Enclosure 3)
TS SR 4.6.1.4.d.2 (Enclosure 4)
DESCRIPTION OF THE PROPOSED TECHNICAL SPECIFICATION CHANGE Refer to Attachment 2 for a marked-up copy of the affected Technical Specification pages. Is stated above, a one-time change to surveillance intervals is being requested to allow the tests to be extended through RFO-5.
The surveillance frequencies to be extended are being annotated to permit the tests to be performed during RFO-5.
ENVIRONMENTAL CONSIDERATION The proposed Technical Specification change request was evaluated against the criteria of 10 CFR 51.22 for environmental considerations. The proposed change does not increase the types and amounts of effluents that may be released offsite, does not significantly increase individual or cumulative occupational radiation exposures, and as discussed in Attachment 3, does not involve a significant hazards consideration. Based on the foregoing, it has been concluded that the proposed Technical Specification change meets the criteria given in 10 CFR 51.22(c)(9) for categorical exclusion from the requirement for an Environmental Impact Statement.
. Encloruro 1 ENCLOSURE 1 JUSTIFICATION FOR SURVEILLANCE INTERVAL EXTENSION LOGIC SYSTEM FUNCTIONAL TESTING FOR TECHNICAL SPECIFICATION SR 4.3.1.2, TABLE 4.3.1.1-1, ITEM 13, SR 4.1.3.1.4.a.1 AND SR 4.1.3.1.4.a.2 REACTOR PROTECTION SYSTEM MANUAL SCRAM AND SCRAM DISCHARGE VOLUME VENT AND DRAIN VALVE OPERABILITY REACTOR PROTECTION SYSTEM t
Technical Specifi' cation SR 4.3.1.2 requires : LSFT and simulated automatic actuation of all channels of the Reactor Protection System (RPS) at least once 1
per 18 months (with a maximum allowable surveillance interval extension of 4.5 months per TS 4.0.2).
The Manual Scram functional unit (TS Table 4.3.1.1-1, Item 13) provides for manual initiation of the RPS logic including closure and opening (upon logic reset) of the Scram Discharge Volume (SDV) Vent and Drain Valves, as required by TS SRs 4.1.3.1.4.a.1 and 4.1.3.1.4.a.2. The Manual Scram functional unit of TS Table 4.3.1.1-1 and the SDV Vent and Drain Valves closure within 30 seconds and opening per TS SRs 4.1.3.1.4.a.1 and 4.1.3.1.4.a.2, respectively, require a surveillance interval extension for a nominal period of 24 days to reach the most conservative projected start of RFO-5. However, in that the Manual Scram functional unit is required to be OPERABLE in Operational Conditions 1, 2, 3, 4 and 5, a total extension of the surveillance interval for this functional unit to the most' conservative projected end of RFO-5 for a nominal period of 116 days is required.
As stated in the NRC Safety Evaluation Report (dated August 2, 1993) related to extension of the Peach Bottom Atomic Power Station, Unit Numbers 2 and 3, surveillance intervals from 18 to 24 months:
" Industry reliability studies for boiling vater reactors (BVRs),
prepared by the BVR Ovners Group (NEDC-30936P) show that the overall safety systems' reliabilities are not dominated by the reliabilities of the logic system, but by that of the mechanical components, (e.g., pumps and valves), which are consequently tested on a more frequent basis...Since the probability of a relay or contact failure is small relative to the probability of mechanical component failure, increasing the logic system functional test interval represents no significant change in the overall safety system unavailability."
The SDV Vent and Drain Valves are required to be cycled at least once per 92 days by TS SR 4.1.3.1.1.a thereby verifying that the valves are capable of closing and opening. The logic providing input to close the valves within 30 seconds requires extension. and open the valves is the only remaining portion of the SRs which In that this logic is the subject to the evaluation above, and the valves are cycled periodically during the operating cycle, the extension of the surveillance intervals for SRs 4.1.3.1.4.a.1 and 4.1.3.1.4.a.2 for a nominal RFO-5 isperiod of 37 days to reach the most conservative projected start of justified.
The evaluation above is applicable to PNPP and the surveillance interval extension for the TS Table 4.3.1.1-1, Item 13 functional unit (Manual Scram) for a nominal period of 116 days is bounded by the interval accepted on the Peach Bottom docket; therefore, the surveillance interval extension is justified.
+ o m - - - . ~ ~ ~
- . . _ - . . _ . . . _ _ _ _ _ _ _ . .-. -. _ _ _ _ - .-_ _ .._.~ _ _ . _ _ _ . _ . _ _ _
Enclo3uro 2 ENCLOSURE 17 JUSTIFICATION FOR SURVEILLANCE INTERVAL EXTENSION LOGIC SYSTEM FUNCTIONAL TESTING FOR TECHNICAL SPECIFICATION SR 4.3.1.2, TABLE 4.3.1.1-1, ITEM 12 AND CHANNEL FUNCTIONAL TESTING FOR TECHNICAL SPECIFICATION SR 4.3.6.1, TABLE 4.3.6-1, ITEM 7 REACTOR H0DE SVITCH SHUTDOWN POSITION REACTOR PROTECTION SYSTEM AND
.. CONTROL ROD BLOCK INSTRUNENTATION Technical Specification SR 4.3.1.2 requires a LSFT and simulated automatic actuation of all channels of the Reactor Protection System at least once per 18 months (with a maximum allovable surveillance interval extension of 4.5 months per TS 4.0.2). Technical Specification SR 4.3.6.1 requires a Channel Functional l
Test Control Rod Block trip systems and instrumentation at least once per 18 :
months per TS 4.0.2). (with a maximum allovable surveillance interval extension of 4.5 months The Reactor Mode Switch Shutdown Position functional unit (TS Table 4.3.1.1-1, Item 12 and TS Table 4.3.6-1, Item 7) requires a surveillance interval extension for this functional unit's portion of the LSFT and Channel !
j Functional Test for a nominal period of 24 days to reach the most conservative projected start of RFO-5. However, in that this functional unit is required to be OPERABLE in Operational Conditions 1, 2, 3, 4 and 5, a total extension of the surveillance interval to the most conservative projected end of RPO-5 for a nominal period of 116 days is required.
As stated in the NRC Safety Evaluation Report (dated August 2,1993) related to I extension of the Peach Bottom Atomic Power Station, Unit Numbers 2 and 3, surveillance intervals from 18 to 24 months:
" Industry reliability studies for boiling water reactors (BWRs),
prepared by the BWR Owners Group (NEDC-30936P) show that the overall safety systems' reliabilities are not dominated by the reliabilities of the logic system, but by that of the mechanical components, (e.g., pumps and valves), which are consequently tested on a more frequent basis...Since the probability of a relay or contact failure is small i
relative to the probability of mechanical component failure, increasing ;
the logic system functional test interval represents no significant l
change in the overall safety system unavailability." !
The channel Functional Test for the control Rod Block trip function of the Reactor Mode Switch Shutdown Position provides a verification of the logic (alarm and trip functions) within the channel. Therefore, the evaluation above 1 is applicable to the' Channel Functional Test for the Control Rod Block instrumentation. i I
The evaluation above is applicable to PNPP and the surveillance interval extension for a nominal period of 116 days is bounded by the interval accepted on the Peach Bottom docket; therefore, the surveillance interval extension is justified.
Enclorurs 3 1
ENCLOSURE 88 JUSTIFICATION FOR SURVEILLANCE INTERVAL EXTENSION l FUNCTIONAL TEST FOR TECHNICAL SPECIFICATION SR 4.6.1.4.C.1 MSIV LEAKAGE CONTROL SYSTEM Technical Specification SR 4.6.1.4.c.1 requires that a functional test,
, including simulated actuation throughout the operating sequence, be performed on i
the HSIV Leakage control subsystems at least once per 18 months (with a maximum allovable surveillance interval extension of 4.5 months per TS 4.0.2). The
! functional test also includes verification that each automatic valve in the flov l path actuates to its correct position and the blower starts. This SR requires j extension of the surveillance interval for a nominal period of 21 days to reach the most conservative project start of RF0-5.
The functional test provides a testing of the logic and functional components of the HSIV Leakage Control System. The functional components, consisting of the valves and blowers, are tested periodically during the operating cycle in accordance with TS SRs 4.6.1.4.a and 4.6.1.4.b. Therefore, the functional' test provides for testing of the logic in conjunction with the functional components.
As stated in the NRC Safety Evaluation Report (dated August 2,1993) related to extension of the Peach Bottom Atomic Power Station, Unit Numbers 2 and 3, surveillance intervals from 18 to 24 months:
" Industry reliability studies for boiling water reactors (BVRs),
prepared by the BVR Owners Group (NEDC-30936P) show that the overall safety systems' reliabilities are not dominated by the reliabilities of the logic system, but by that of the mechanical components, (e.g., pumps and valves), which are consequently tested on a more frequent basis...Since the probability of a relay or contact failure is small relative to the probability of mechanical component failure, increasing the logic system functional test interval represents no significant change in the overall safety system unavailability."
The simulated actuation test is supplemented during the operating cycle by tests performed on instrumentation and mechanical components of the system. These include CHANNEL CHECKS, CHANNEL FUNCTIONAL TESTS, Inservice Testing and other component verification surveillances as specified by the TS. In that the simulated actuation test is required to assure system operability during the operating cycle, and periodic testing is performed during the operating cycle, the requested extension to the surveillance interval is justified.
The LSFT evaluation above is applicable to PNPP and the surveillance interval extension for a nominal period of 21 days is bounded by the interval accepted on the Peach Bottom docket. The simulated actuation test is supplemented during the cycle to assure operability. Based on these considerations, the surveillance interval extension is justified.
-. .. -. _ _ -- ~. - -. - - - - _ . - - - . . .- _ -- - .- - - .
- Enclosurs 4 9
~
ENCLOSURE 89 JUSTIFICATION FOR SURVEILLANCE INTERVAL EXTENSION TECHNICAL SPECIFICATION SR 4.6.1.4.d.2 REACTOR VESSEL PRESSURE CALIBRATION HSIV LEAKAGE CONTROL SYSTEM INSTRUMENTATION Technical Specification SR 4.6.1.4.d.2 requires the HSIV Leakage Control System Reactor Vessel Pressure Instrumentation to be demonstrated OPERABLE by performance of a 'hannel c calibration at least once per 18 months (with a maximum allovable extension of 4.5 months per TS 4.0.2). The pressure transmitters, Rosemount Model 1153 level transmitters, vill require an extension of the SR interval cited in TS Table 4.6.1.4.d.2 for a nominal period of 52 days to reach the most conservative projected start of RFO-5.
In February 1990, Rosemount published a report, "30 Month Stability l Specification For Rosemount Model 1152, 1153, 1154 Pressure Transmitters" (Rosemount Report D8900126, Revision A) [ accepted by NRC Safety Evaluation Report dated August 2,1993 on the Peach Bottom Atomic Power Station, Unifs 2 and 3 docket.] This report supported the extension of the calibration interval for the transmitters from 18 months to 30 months based on a reduction in the drif t allowance from 0.29% URL (2 sigma) for 18 months to 0.20% URL (2 sigma) for 30 months. In addition, applicable setpoint calculations assumed 18 month !
calibration of the trip interval for trip units. However, the trip units are l calibrated either monthly or quarterly, depending on the TS requirement for channel functional testing.
The MSIV Leakage Control System is a manually inititated system. The Reactor Vessel Pressure transmitters and trip units provide a permissive and trip function for operation of the Leakage Control System blowers and valves. The setpoint for transmitters and trip units was established based on the time that the Leakage control System should be shutdown, if operating. The allowable value for this setpoint was established as 1.5 times the Leave-As-Is-Zone to provide a reasonable operability limit for the transmitters and trip units. l Sufficient margin exists between the Nominal Trip Setpoint and the site-established Allowable Value to justify the surveillance interval extension.
The margin is significantly greater than the 30 month transmitter drift and trip ,
unit drift uncertainty values applicable to the Rosemount instruments. I Therefore, the requested extension is justified. I 1
l l
. - -_