NRC 2009-0046, Annual Monitoring Report, Appendix 1 Through End

From kanterella
Jump to navigation Jump to search
Annual Monitoring Report, Appendix 1 Through End
ML091380404
Person / Time
Site: Point Beach  
Issue date: 04/30/2009
From: Jim Costedio
Nextera Energy
To:
Office of Nuclear Reactor Regulation
References
FOIA/PA-2010-0209, NRC 2009-0046
Download: ML091380404 (92)


Text

APPENDIX 1 ENVIRONMENTAL, INC., MIDWEST LABORATORY RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP)

FOR THE POINT BEACH NUCLEAR PLANT TWO RIVERS, WISCONSIN REPORTING PERIOD: JANUARY - DECEMBER 2008

Environmental, Inc.

Midwest Laboratory an Allegheny Technologies Co.

700 Landwehr Road - Northbrook, IL 60062-2310 (817) 564-0700 fax (847) 564-4517 FINAL REPORT TO FPL ENERGY RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP)

FOR THE POINT BEACH NUCLEAR PLANT TWO RIVERS, WISCONSIN PREPARED AND SUBMITTED BY ENVIRONMENTAL INCORPORATED MIDWEST LABORATORY Project Number: 8006 Reporting Period: January-December, 2008

,C4

..-*J I Z."a Reviewed and Approved by -

Date 02-12-200(?

Manager Distribution:

K. Johansen, 1 e-mail

Section POINT BEACH NUCLEAR PLANT TABLE OF CONTENTS Page L ist o f T a b le s.............................................................................

iii INTR O D U C T IO N..................................................................

1 LISTING OF MISSED SAMPLES....................

2 1.0 2.0 Appendices A

B C

D E

Interlaboratory Comparison Program Results.......................

A-1 Data Reporting Conventions.................................................

B-1 Sampling Program and Locations........................................

C-1 G raphs of Data Trends..........................................................

D-1 Supplemental Analyses........................................................

E-1 ii

POINT BEACH NUCLEAR PLANT LIST OF TABLES Title Page Airborne Particulates and Iodine-1 31 Location E-01, M eteorological Tower.................................................

4 Location E-02, Site Boundary Control Center...................................

5 Location E-03, W est Boundary..........................................................

6 Location E-04, North Boundary..........................................................

7 Location E-08, G. J. Francar Residence............................................

8 Location E-20, Silver Lake College.........................................................

9 Airborne Particulates, Gam m a Isotopic Analyses..........................................

10 M ilk.....................................................................................................................

1 1 W ell W ater.....................................................................................................

17 Lake W ater.....................................................................................................

18 Lake W ater, Analyses on Q uarterly Com posites..........................................

22 F is h.....................................................................................................................

2 5 Shoreline Sedim ents.....................................................................................

28 S o il.......................................................................................................................

3 0 Vegetation.......................................................................................................

32 Aquatic Vegetation..........................................................................................

35 Gam m a Radiation, as M easured by TLDs.....................................................

36 G roundwater M onitoring Program..................................................................

40 iii

POINT BEACH NUCLEAR PLANT

1.0 INTRODUCTION

The following constitutes the final 2008 Monthly Progress Report for the Environmental Radiological Monitoring Program conducted at the Point Beach Nuclear Plant, Two Rivers, Wisconsin. Results of analyses are presented in the attached tables. Data tables reflect sample analysis results for both Technical Specification requirements and Special Interest locations and samples are randomly selected within the Program monitoring area to provide additional data for cross-comparisons.

For gamma isotopic analyses, the spectrum covers an energy range from 80 to 2048 KeV. Specifically included are Mn-54, Fe-59, Co-58, Co-60, Zn-65, Zr-95, Nb-95, Ru-103, Ru-106, 1-131, Ba-La-140, Cs-134, Cs-137, Ce-141, and Ce-144. Naturally occurring gamma-emitters, such as K-40 and Ra daughters, are frequently detected in soil and sediment samples. Specific isotopes listed are K-40, TI-208, Pb-212, Bi-214, Ra-226 and Ac-228. Unless noted otherwise, the results reported under "Other Gammas" are for Co-60 and may be higher or lower for other radionuclides.

All concentrations, except gross beta, are decay corrected to the time of collection.

All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.

1

POINT BEACH NUCLEAR PLANT 2.0 LISTING OF MISSED SAMPLES Expected Collection Sample Type Location Date Reason AP/AI AP/AI AP/AI AP/AI LW LW E-02 E-04 E-02 E-03 E-01 E-06 03-19-08 GFI breaker inside site boundary building was blown.

06-19-08 Loss of power at sampler.

09-03-08 Equipment failure.

12-30-08 Loss of power at sampler.

12-17-08 Inaccessible due to icy conditions.

12-17-08 Inaccessible due to icy conditions.

NOTE: Page 3 is intentionally left out.

2

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-1 31.

Location: E-01, Meteorological Tower Units: pCi/m 3

Collection:

Continuous, weekly exchange.

Date Vol.

Collected (M3)

Gross Beta 1-131 Date Vol.

Collected (M3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01-09-08 01-16-08 01-23-08 01-31-08 02-07-08 02-13-08 02-20-08 02-28-08 03-06-08 03-12-08 03-19-08 03-27-08 04-03-08 1 st Quarter Mean +/- s.d.

04-10-08 04-17-08 04-23-08 05-01-08 05-08-08 05-15-08 05-21-08 05-29-08 06-05-08 06-12-08 06-19-08 06-25-08 07-02-08 2nd Quarter Mean +/- s.d.

272 274 278 370 325 280 319 370 321 277 324 371 321 0.027 +/- 0.004 0.028 +/- 0.004 0.035 +/- 0.004 0.042 +/- 0.004 0.025 + 0.004 0.038 +/- 0.005 0.036 +/- 0.004 0.028 + 0.003

< 0.014

< 0.014

< 0.014

< 0.014

< 0.024

< 0.019

< 0.011

< 0.009

< 0.015

< 0.013

< 0.008

< 0.020

< 0.008 0.028 0.034 0.021 0.022 0.022

+ 0.004

+ 0.004

+ 0.003

+/- 0.003

+ 0.004 0.030 +/- 0.007

< 0.014 07-09-08 07-16-08 07-23-08 07-30-08 08-06-08 08-13-08 08-21-08 08-25-08 09-03-08 09-11-08 09-17-08 09-24-08 10-01-08 3rd Quarter Mean +/- s.d.

10-09-08 10-15-08 10-23-08 10-29-08 11-06-08 11-12-08 11-19-08 11-26-08 12-03-08 12-10-08 12-17-08 12-23-08 12-30-08 4th Quarter Mean + s.d.

335 316 320 326 332 318 365 178 362 343 250 294 291 0.017 +/- 0.003 0.016 +/- 0.003 0.021 + 0.003 0.021 + 0.003 0.017 +/- 0.003 0.011 _ 0.003 0.019 + 0.003 0.025 + 0.005 0.039 + 0.003 0.022 + 0.003

.0.022 + 0.004 0.032 +/- 0.004 0.035 +/- 0.004 0.023 +/- 0.008 < 0.014

< 0.010

< 0.017

< 0.010

< 0.010

< 0.010

< 0.019

< 0.013

< 0.026

< 0.008

< 0.017

< 0.015

< 0.019

< 0.008 327 322 280 372 318 324 302 370 323 325 322 278 324 0.023 +/- 0.003 0.016 +/- 0.003 0.025 +/- 0.004 0.024 +/- 0.003 0.023 +/- 0.003 0.010 +/- 0.003 0.013 +/- 0.003 0.009 +/- 0.002 0.017 +/- 0.003 0.008 +/- 0.003 0.009 +/- 0.003 0.010 +/- 0.003 0.018 +/- 0.003

< 0.012

< 0.008.

< 0.014

< 0.015

< 0.014

< 0.009

< 0.009

< 0.013

< 0.017

< 0.010

< 0.015

< 0.010

< 0.015 334 253 334 253 336 249 297 292 294 297 290 250 293 0.017 0.033 0.020 0.019

+ 0.003

+ 0.004

+/- 0.003

+/- 0.003 0.045 +/- 0.004 0.013 +/- 0.003 0.025 +/- 0.003 0.031 +/- 0.004 0.027 +/- 0.003 0.024 +/- 0.003 0.032 +/- 0.004 0.047 +/- 0.005 0.053 +/- 0.004

< 0.015

< 0.020

< 0.012

< 0.017

< 0.017

< 0.022

< 0.016

< 0.010

< 0.017

/

< 0.016

< 0.015

< 0.013 ""

< 0.009 7 0.016 +/- 0.006 < 0.012 0.030 +/- 0.012

< 0.015 Cumulative Average 0.025 +/- 0.010

< 0.014 4

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-1 31.

Location: E-02, Site Boundary Control Center Units: pCi/m 3

Collection:

Continuous, weekly exchange.

Date Vol.

Collected (M3)

Gross Beta 1-131 Date Vol.

Collected (M3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01-09-08 01-16-08 01-23-08 01-31-08 02-07-08 02-13-08 02-20-08 02-28-08 03-06-08 03-12-08 03-19-08 03-27-08 04-03-08 1 st Quarter Mean +/- s.d.

04-10-08 04-17-08 04-23-08 05-01-08 05-08-08 05-15-08 05-21-08 05-29-08 06-05-08 06-12-08 06-19-08 06-25-08 07-02-08 2nd Quarter Mean +/- s.d.

264 300 301 346 304 262 299 345 0.025 +/- 0.004

.0.025 +/- 0.004 0.039 +/- 0.004 0.037 +/- 0.004 0.022 0.037 0.033 0.026

+/- 0.004

+/- 0.005

+/- 0.004

+/- 0.003

< 0.014

< 0.013

< 0.012

< 0.015

< 0.025

< 0.020

< 0.011

< 0.010

< 0.017

<0.014

< 0.024

< 0.009 07-09-08 07-16-08 07-23-08 07-30-08 08-06-08 08-13-08 08-21-08 08-25-08 09-03-08 09-11-08 09-17-08 09-24-08 10-01-08 312 295 300 305 309 298 341 171 305 248 301 280 0.015 +/- 0.003 0.016 +/- 0.003 0.022 +/- 0.003 0.025 +/- 0.003 0.018 +/- 0.003 0.013 +/- 0.003 0.023 +/- 0.003 0.029 +/- 0.005 NSa 0.017 +/- 0.003 0.022 +/- 0.004 0.032 +/- 0.004 0.032 +/- 0.004

< 0.011

<0.019

< 0.011

< 0.011

< 0.011

< 0.021

< 0.014

< 0.027

< 0.019

< 0.015

< 0.018

< 0.009 300 0.027 +/- 0.004 258 0.033 +/- 0.004 NSa 337 0.022 +/- 0.003 300 0.016 +/- 0.003 3rd Quarter Mean +/- s.d.

307 300 261 348 296 305 259 346 301 304 301 259 303 0.029 +/- 0.007 0.021 +/- 0.003 0.017 +/- 0.003 0.022 +/- 0.004 0.023 +/- 0.003 0.022 +/- 0.003 0.010 +/- 0.003 0.016 +/- 0.004 0.009 +/- 0.002 0.030 +/- 0.004 0.003 +/- 0.003 0.012 +/- 0.003 0.013 +/- 0.004 0.018 +/- 0.003

< 0.015

< 0.013

< 0.009

< 0.015

<0.016

< 0.015

< 0.009

< 0.011

< 0.013

< 0.019

< 0.010

< 0.016

< 0.010

< 0.016 0.022 +/- 0.007 < 0.016

.10-09-08 10-15-08 10-23-08 10-29-08 11-06-08 11-12-08 11-19-08 11-26-08 12-03-08 12-10-08 12-17-08 12-23-08 12-30-08 320 243 320 242 323 239 284 280 282 285 279 239 282 0.018 +/- 0.003 0.037 +/- 0.004 0.022 +/- 0.003 0.020 +/- 0.004 0.050 +/- 0.004 0.014 +/- 0.003 0.022 +/- 0.003 0.028 +/- 0.004 0.031 +/- 0.004

< 0.016

< 0.021

< 0.012

< 0.018

< 0.018

< 0.023

< 0.016

< 0.010

< 0.018 j

< 0.017

< 0.015'

< 0.014

< 0.010

//0.021

/0.031

/0.041

,0.049

+/- 0.003

+/- 0.004

+/- 0.005

+/- 0.004 0.017 +/- 0.007

< 0.013 4th Quarter Mean +/- s.d.

0.029 +/- 0.012 <0.016 0.024 +/- 0.009 < 0.015 a "NS" = No sample; see Table 2.0, Listing of Missed Cumulative Average Samples.

5

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location: E-03, West Boundary Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Vol.

Collected (M3)

Gross Beta 1-131 Date Vol.

Collected (m3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01-09-08 01-16-08 01-23-08 01-31-08 02-07-08 02-13-08 02-20-08 02-28-08 03-06-08 03-12-08 03-19-08 03-27-08 04-03-08 1st Quarter Mean +/- s.d.

04-10-08 04-17-08 04-23-08 05-01-08 05-08-08 05-15-08 05-21-08 05-29-08 06-05-08 06-12-08 06-19-08 06-25-08 07-02-08 2nd Quarter Mean +/- s.d.

263 300 301 346 304 262 299 345 300 260 301 347 301 0.027 +/- 0.004 0.029 +/- 0.004 0.039 +/- 0.004 0.038 +/- 0.004 0.025 +/- 0.004 0.040 +/- 0.005 0.035 +/- 0.004 0.025 +/- 0.003 0.027 +/- 0.004 0.028 +/- 0.004 0.019 +/- 0.003 0.017 +/- 0.003 0.018 +/- 0.004

< 0.014

< 0.013

< 0.013

< 0.015

< 0.025

< 0.020

<0.011

< 0.010

< 0.017

< 0.014

< 0.008

< 0.025

< 0.009 0.028 +/- 0.008 < 0.015 306 300 261 348 297 304 259 346 301 304 301 260 302 0.021 0.015 0.025 0.024

+/- 0.003

+/- 0.003

+/- 0.004

+/- 0.003 0.020 +/- 0.003 0.009 +/- 0.003 0.013 +/- 0.003 0.008 +/- 0.002 0.014 +/- 0.003 0.007 +/- 0.003 0.009 +/- 0.003 0.011 +/- 0.004 0.018 +/- 0.003

< 0.013

< 0.009

< 0.015

< 0.016

< 0.015

< 0.009

<0.011

< 0.013

<0.019

< 0.010

< 0.016

< 0.010

< 0.016 07-09-08 07-16-08 07-23-08 07-30-08 08-06-08 08-13-08 08-21-08 08-25-08 09-03-08 09-11-08 09-17-08 09-24-08 10-01-08 3rd Quarter Mean +/- s.d.

10-09-08 10-15-08 10-23-08 10-29-08 11-06-08 11-12-08 11-19-08 11-26-08 12-03 12-10-08/

12-17-08"/

12-23-08 /

12-30-08 "/

4th Quarter Mean +/- s.d.

0.020 +/- 0.006 < 0.015 313 292 292 301 303 299 330 162 377 337 250 294 292 0.015 0.015 0.020 0.021

+/- 0.003

+/- 0.003

+/- 0.003

+/- 0.003 0.015 +/- 0.003 0.011 +/- 0.003 0.020 +/- 0.003 0.023 +/- 0.005 0.029 +/- 0.003 0.015 +/- 0.003 0.016 +/- 0.003 0.029 +/- 0.004 0.031 +/- 0.004 337 251 333 253 336 250 300 289 293 297 291 250 0.017 +/- 0.003 0.031 +/- 0.004 0.016 +/- 0.003 0.021 +/- 0.004 0.041 0.013 0.021 0.024 0.028

<0.011

< 0.019

< 0.011

< 0.011

<0.011

< 0.021

< 0.014

< 0.029

<.0.008

< 0.017

< 0.015

< 0.019

<.0.008

+/- 0.004

+/- 0.003

+/- 0.003

+/- 0.003

+/- 0.003

< 0.015

< 0.020

< 0.012

< 0.017

< 0.017

< 0.022

< 0.016

<0.010

< 0.017

<0.016

< 0.015

< 0.013 0.024 +/- 0.003 0.034 +/- 0.004 0.039 +/- 0.004 NS3 0.015 +/- 0.006 < 0.013 0.026 +/- 0.009 < 0.016 0.022 +/- 0.008 <0.015 Cumulative Average a "NS" = No sample; see Table 2.0, Listing of Missed Samples.

6

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-1 31.

Location: E-04, North Boundary E-004 Units: pCi/m 3 Collection: Continuous, weekly exchange.

Date Vol.

Collected (M3)

Gross Beta 1-131 Date Vol.

Collected (M3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 01-09-08 01-16-08 01-23-08 01-31-08 02-07-08 02-13-08 02-20-08 02-28-08 03-06-08 03-12-08 03-19-08 03-27-08 04-03-08 1 st Quarter Mean +/- s.d.

04-10-08 04-17-08 04-23-08 05-01-08 05-08-08 05-15-08 05-21-08 05-29-08 06-05-08 06-12-08 06-19-08 06-25-08 07-02-08 2nd Quarter Mean +/- s.d.

297 339 340 391 343 296 337 390 339 293 341 379 330 0.028 0.028 0.038 0.037

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.003 0.024 +/- 0.003 0.036 +/- 0.004 0.035 +/- 0.004 0.027 +/- 0.003 0.025 +/- 0.004 0.029 +/- 0.004 0.018 +/- 0.003 0.019 + 0.003 0.017 + 0.003

< 0.013

< 0.011

< 0.011

< 0.013

< 0.022

< 0.018

< 0.010

< 0.009

< 0.015

< 0.013

< 0.007

< 0.021

< 0.008 0.028 +/- 0.007 333 317 275 367 335 321 273 378 340 344 274 319 0.020 0.014 0.024 0.021

+/- 0.003

+/- 0.003

+/- 0.004

+/- 0.003 0.024 +/- 0.003 0.010 +/- 0.003 0.015 +/- 0.003 0.009 +/- 0.002 0.014 +/- 0.003 0.008 +/- 0.003 NSa 0.013 +/- 0.003 0.020 +/- 0.003

< 0.013

< 0.012

< 0.008

< 0.014

< 0.016

< 0.014

< 0.009

< 0.010

< 0.012

< 0.016

< 0.009

< 0.010

< 0.015 07-10-08 07-16-08 07-23-08 07-30-08 08-06-08 08-13-08 08-21-08 08-25-08 09-03-08 09-11-08 09-17-08 09-24-08 10-01-08 3rd Quarter Mean +/- s.d.

10-09-08 10-15-08 10-23-08 10-29-08 11-06-08 11-12-08 11-19-08 11-26-08 12-03 12-10-08 /

12-17-08 /

12-23-08 /

12-30-08 -/

4th Quarter Mean +/- s.d.

0.021 +/- 0.005 380 285 378 288 380 283 339 329 332 337 331 282 302 363 284 320 328 330 316 360 184 427 388 278 333 332 0.014 +/- 0.003 0.017 +/- 0.003 0.021 +/- 0.003 0.024 +/- 0.003 0.020 +/- 0.003 0.013 +/- 0.003 0.021 +/- 0.003 0.024 +/- 0.004 0.029 +/- 0.003 0.016 +/- 0.002 0.017 +/- 0.003 0.028 +/- 0.003 0.027 +/- 0.003 0.018 0.028 0.018 0.020

+/- 0.003

+/- 0.004

+/- 0.003

+/- 0.003 0.038 +/- 0.003 0.010 +/- 0.003 0.019 +/- 0.003 0.024 +/- 0.003 0.026 +/- 0.003 0.020 +/- 0.003 0.024 +/- 0.003 0.039 +/- 0.004 0.045 +/- 0.004 0.030

< 0.009

< 0.019

< 0.010

< 0.010

< 0.010

< 0.020

<0.013

< 0.025

< 0.007

< 0.013

< 0.013

< 0.016

< 0.007

< 0.013

< 0.013

< 0.018

< 0.010

< 0.015

< 0.015

<0.019

< 0.014

< 0.009

< 0.015

< 0.014

< 0.013

< 0.012

< 0.009 0.016 +/- 0.006

< 0.012 0.025 +/- 0.010 < 0.014 Cumulative Average 0.023 +/- 0.008 < 0.013 a "NS" = No sample; see Table 2.0, Listing of Missed Samples.

7

POiNT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location: E-08, G.J. Francar Residence Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Vol.

Collected (M3)

Gross Beta 1-131 Date Vol.

Collected (M3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01-09-08 01-16-08 01-23-08 01-31-08 02-07-08 02-13-08 02-20-08 02-28-08 03-06-08 03-12-08 03-19-08 03-27-08 04-03-08 1 st Quarter Mean +/- s.d.

271 309 310 356 313 270 308 355 309 266 312 357 312 0.025 0.028 0.035 0.041

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.004 0.021 + 0.003 0.032 + 0.004 0.033 + 0.004 0.026 +/- 0.003 0.026 + 0.004 0.029 +/- 0.004 0.015 +/- 0.003 0.021 +/- 0.003 0.020 +/- 0.004

< 0.014

< 0.012

< 0.012

< 0.014

< 0.024

< 0.020

< 0.011

< 0.009

< 0.016

< 0.014

< 0.008

< 0.022

< 0.009 07-10-08 07-16-08 07-23-08 07-30-08 08-06-08 08-13-08 08-21-08 08-25-08 09-03-08 09-11-08 09-17-08 09-24-08 10-01-08 354 273 307 315 316 309 356 175 384 349 247 283 302 0.014 0.018 0.024 0.019

+/- 0.003

+/- 0.004

+/- 0.003

+/- 0.003 0.017 +/- 0.003 0.012 +/- 0.003 0.022 +/- 0.003 0.023 +/- 0.004 0.034 +/- 0.003 0.015 +/- 0.003 0.018 +/- 0.003 0.046 +/- 0.004 0.031 +/- 0.004

< 0.009

< 0.020

< 0.010

< 0.011

< 0.010

< 0.020

< 0.013

< 0.026

< 0.008

< 0.016

< 0.015

< 0.019

< 0.008 0.027 +/- 0.007

< 0.014 04-10-08 04-17-08 04-23-08 05-01-08 05-08-08 05-15-08 05-21-08 05-29-08 06-05-08 06-12-08 06-19-08 06-25-08 07-02-08 313 309 269 358 306 314 267 357 310 314 310 268 311 0.022 +/- 0.003 0.015 +/- 0.003 0.023 +/- 0.004 0.023 +/- 0.003 0.021 0.010 0.011 0.009

+/- 0.003

+/- 0.003

+/- 0.003

+/- 0.002

< 0.013

< 0.009

< 0.015

< 0.016

< 0.015

< 0.009

< 0.010

< 0.013

< 0.018

< 0.010

< 0.016

< 0.010

< 0.016 3rd Quarter Mean +/- s.d.

10-09-08 10-15-08 10-23-08 10-29-08 11-06-08 11-12-08 11-19-08 11-26-08 12-03-08 "

346 261 341 264 344 258 306 300 302 306 301 256 302 0.019 +/- 0.003 0.031 +/- 0.004 0.018 +/- 0.003 0.021 t 0.003 0.045 +/- 0.004 0.014 +/- 0.003 0.019 +/- 0.003 0.024 +/- 0.003 0.030 +/- 0.004 0.023 +/- 0.010 < 0.014

< 0.014

< 0.019

< 0.011

< 0.016

< 0.017

< 0.021

< 0.015

< 0.009

< 0.017

< 0.016

< 0.014

< 0.013

< 0.009 0.018 +/- 0.003 0.009 +/- 0.003 0.010 +/- 0.003 0.011 +/- 0.003 0.018 +/- 0.003 12-10-08 12-17-08 12-23-08 12-30-08

/

/

/

/

0.024 0.036 0.045 0.048

+/- 0.003

+/- 0.004

+/- 0.005

+/- 0.004 2nd Quarter Mean +/- s.d.

4th Quarter Mean +/- s.d.

0.015 +/- 0.006

< 0.013 0.029 +/- 0.012 < 0.015 0.024 +/- 0.010 < 0.014 Cumulative Average 8

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location: E-20, Silver Lake Units: pCi/m 3

Collection:

Continuous, weekly exchange.

Date Vol.

Collected (M3)

Gross Beta 1-131 Date Vol.

Collected (M3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01-09-08 01-16-08 01-23-08 01-31-08 02-07-08 02-13-08 02-20-08 02-28-08 03-06-08 03-12-08 03-19-08 03-27-08 04-03-08 1 st Quarter Mean +/- s.d.

04-10-08 04-17-08 04-23-08 05-01-08 05-08-08 05-15-08 05-21-08 05-29-08 06-05-08 06-12-08 06-19-08 06-25-08 07-02-08 2nd Quarter Mean +/- s.d.

264 300 302 345 303 262 299 345 301 260 304 346 304 0.025 +/- 0.004 0.034 +/- 0.004 0.039 + 0.004 0.060 +/- 0.004 0.026 +/- 0.004 0.038 + 0.005 0.034 +/- 0.004 0.027 + 0.004 0.028 +/- 0.004 0.033 +/- 0.004 0.015 +/- 0.003 0.022 +/-0.003 0.019 + 0.004

< 0.014

< 0.013

< 0.012

< 0.015

< 0.025

< 0.020

< 0.011

< 0.010

< 0.016

< 0.014

< 0.008

< 0.025

< 0.009 07-09-08 07-16-08 07-23-08 07-30-08 08-06-08 08-13-08 08-21-08 08-25-08 09-03-08 09-11-08 09-17-08 09-24-08 10-01-08 3rd Quarter Mean +/- s.d.

10-09-08 10-15-08 10-23-08 10-29-08 11-06-08 11-12-08 11-19-08 11-26-08 12-03-08 305 303 298 305 303 306 327 160 368 347 258 303 305 0.019 +/- 0.003 0.016 +/- 0.003 0.028 +/- 0.003 0.023 +/- 0.003 0.018 +/- 0.003 0.012 +/- 0.003 0.022 +/- 0.003 0.035 +/- 0.005 0.026 +/- 0.003 0.016 +/- 0.003 0.019 +/- 0.003 0.035 +/- 0.004 0.028 +/- 0.003

<0.011

< 0.018

< 0.011

< 0.011

< 0.011

< 0.020

< 0.014

< 0.029

< 0.008

< 0.017

< 0.014

< 0.018

< 0.008 303 301 260 348 297 304 262 344 300 305 301 261 302 0.031 +/- 0.011 0.021 +/- 0.004 0.015 + 0.003 0.025 +/- 0.004 0.022 +/- 0.003 0.021 +/- 0.003 0.013 +/- 0.003 0.012 +/- 0.003 0.009 +/- 0.002 0.017 +/- 0.003 0.008 +/- 0.003 0.012 +/- 0.003 0.015 +/- 0.004 0.021 + 0.003

< 0.015

< 0.013

< 0.009

< 0.015

< 0.016

< 0.015

< 0.009

< 0.011

< 0.014

< 0.019

<0.010

< 0.016

< 0.010

< 0.016 0.023 +/- 0.007

< 0.015 345 263 337 265 342 262 299 304 302 305 300 257-302 -,

0.019 +/- 0.003 0.030 +/- 0.004 0.017 +/- 0.003 0.022 +/- 0.003 0.041 +/- 0.004 0.012 +/- 0.003 0.021 +/- 0.003 0.021 +/- 0.003 0.029 +/- 0.003 0.024 +/- 0.003 0.034 + 0.004 0.048 +/- 0.005 0.053 +/- 0.004

< 0.014

< 0.019

< 0.012

< 0.016

< 0.017

< 0.021

< 0.016

< 0.009

< 0.016

< 0.016

< 0.014

< 0.013

< 0.009 12-10-08 12-17-08 12-23-08 12-30-08 I"

4th Quarter Mean +/- s.d.

0.016 +/- 0.005 < 0.013 0.028 +/- 0.012

< 0.015 0.025 +/- 0.011 <0.014 0.023 +/- 0.010

< 0.014 Cumulative Average All Locations Annual Mean + s.d.

9

POINT BEACH NUCLEAR PLANT GAMMA EMITTERS IN QUARTERLY COMPOSITES OF AIR PARTICULATE FILTERS (Concentration pCi/m3)

Locatior Lab Code Be-7 Cs-134 Cs-137 Other Gammasa Volume Req. LL 0.01 0.01 (0.10) m3 1st Quarter E-01 E-02 E-03 E-04 E-08 E-20 EAP-1742 1743 1744 1745 1746 1747 0.083 +/- 0.014 0.089 +/- 0.020 0.075 +/- 0.012 0.063 +/- 0.013 0.061 +/- 0.010 0.083 +/- 0.015 0.0002

-0.0009

-0.0001

-0.0002

-0.0003

-0.0002

+

+

+/-

+

0.0004 0.0006 0.0004 0.0004 0.0004 0.0006

-0.0002 +/- 0.0005 0.0000 +/- 0.0006 0.0001 +/- 0.0005

-0.0001 +/- 0.0004

-0.0003 +/- 0.0005

-0.0002 +/- 0.0006

-0.0001 +/- 0.0006

-0.0001 +/- 0.0006 0.0001 +/- 0.0005 0.0000 +/- 0.0004

-0.0001 +/- 0.0005 0.0004 +/- 0.0008 4102 3616 3928 4414 4047 3934 2nd Quarter E-01 E-02 E-03 E-04 E-08 E-20 EAP-3661

- 3662

- 3663,4

-3665

-3666

- 3667 0.073 +/- 0.014 0.075 +/- 0.014 0.078 +/- 0.010 0.075 +/- 0.013 0.056 +/-.0.012 0.075 +/- 0.014 0.0001 0.0002 0.0000

-0.0003 0.0001 0.0003

+

+

+/-

+

0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0000 +/- 0.0005 0.0000 +/- 0.0003

-0.0006 +/- 0.0005

-0.0001 +/- 0.0005 0.0003 +/- 0.0004

-0.0006 +/- 0.0005 0.0004 +/- 0.0005 0.0000 +/- 0.0007

-0.0003 +/- 0.0006 0.0010 +/- 0.0007 0.0002 +/- 0.0006 0.0005 +/- 0.0005 4186 3890 3889 3875 4004 3887 3rd Quarter E-01 E-02 E-03 E-04 E-08 E-20 EAP-5873

- 5874

- 5875

-5876

- 5877

- 5878 0.096 0.060 0.062 0.080 0.090 0.080

+/- 0.018

+/- 0.018

+/- 0.015

+/- 0.014

+/- 0.014

+/- 0.015 0.0000

-0.0002

-0.0003 0.0004 0.0001 0.0002

+/-

+

+

+/-

+

+

0.0005 0.0006 0.0004 0.0004 0.0004 0.0004 0.0000 0.0002 0.0001 0.0001 0.0004

-0.0005

+/- 0.0006

+/- 0.0005

+/- 0.0006

+/- 0.0005

+/- 0.0006

+/- 0.0005

-0.0002

-0.0003 0.0001 0.0000

-0.0001

-0.0002

+/- 0.0008

+/- 0.0009

+/- 0.0006

+/- 0.0006

+/- 0.0006

+/- 0.0006 4031 3464 3840 4244 3971 3890 4th Quarter E-01 E-02 E-03 E-04 E-08 E-20 EAP-7477 7478 7479 7480 7481 7482 0.061 +/- 0.013 0.070 +/- 0.014 0.052 +/- 0.012 0.055 +/- 0.013 0.069 +/- 0.013 0.053 +/- 0.013 0.0001 0.0001

-0.0003

-0.0003 0.0000

-0.0001

+

+

+

+

+

+

0.0004 0.0005 0.0005 0.0005 0.0004 0.0004 0.0002 +/- 0.0003 0.0005 +/- 0.0005 0.0000 +/- 0.0005 0.0003 +/- 0.0003

-0.0001 +/- 0.0005 0.0002 +/- 0.0004 0.0002 0.0003

-0.0001 0.0000 0.0003

-0.0002

+/- 0.0005

+/- 0.0004

+/- 0.0006

+/- 0.0006

+/- 0.0005

+/- 0.0005 3772 3617 3478 4245 3886 3883 a See Introduction Annual Mean+/-s.d.

Indicators Control 0.071 0.071 0.073

++

0.012 0.012 0.015

-0.0001

-0.0001 0.0000

+/-+/-

+_

0.0003 0.0003 0.0002 0.0000 +/- 0.0003 0.0000 +/- 0.0002 0.0001 +/- 0.0003 0.0001 0.0001 0.0001

+/- 0.0003

+/- 0.0003

+/- 0.0002 10

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCi/L)

E-11 Funk Dairy Farm Required LLD Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-134 Cs-137 Ba-La-140 Co-60 Collection Date 01-09-08 EMI-100

-0.3 +/- 1.0 0.8 +/- 0.4 0.25 +/- 0.26 1316 +/- 132

-2.4 +/- 2.3

-1.1 +/- 3.2 2.6 +/- 2.1 3.6 +/- 2.4 04-09-08 EMI-1480 02-13-08 EMI-537

-0.7 +/- 1.0 1.1 +/- 0.4

-0.04 +/- 0.11 1359 +/- 108 0.6 +/- 2.0

-0.8 +/- 2.5 0.4 +/- 2.1

-0.2 +/- 2.7 05-14-08 03-12-08 EMI-1005

-0.2 +/- 0.9 0.9 +/- 0.3

-0.14 +/- 0.17 5.0 1.0 0.5 1373 +/-

-2.1 +/-

-1.3 +/-

2.2 +/-

1.3 +/-

119 2.1 2.8 2.4 3.0 5.0 5.0 5.0 15.0 Required LLD 06-11-08 Lab Code EMI-2365 EMI-2904 Sr-89 Sr-90 1-131

-0.9 +/- 1.1 1.1 +/- 0.4

-1.1 +/- 0.9 1.3 +/- 0.4

-0.13 +/- 0.16

-1.9 +/- 1.0 1.6 +/- 0.4 0.09 +/- 0.13

-0.09 +/- 0.16 K-40 Cs-134 Cs-137 Ba-La-140 Co-60 1245 +/-

-0.2 +/-

-0.6 +/-

-3.0 +/-

1.5 +/-

107 2.4 2.6 2.3 2.7 1352

-0.2 1.7 1.5 1.2

+/-

+/-

+/-

+

110 1.7 1.9 1.8 1.8 1388 +/-

-2.9 +/-

-0.3 +/-

-2.7 +/-

-1.9 +/-

121 2.5 2.4 2.2 2.3 5.0 1.0 0.5 5.0 5.0 5.0 15.0 11

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCi/L)

Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-134 Cs-137 Ba-La-140 Co-60 Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-1 34 Cs-137 Ba-La-140 Co-60 07-09-08 EMI-3445

-0.9 +/- 0.9 0.9 +/- 0.3

-0.19 +/- 0.17 1286 +/- 90

-1.4 +/- 1.6

-1.2 +/- 1.6 0.9 +/- 1.3 1.3 +/- 1.7 10-08-08 EMI-5493

-1.2 +/- 1.2 1.0 +/- 0.4 0.12 +/- 0.16 1369 +/- 104 0.1 +/- 1.4 0.6 +/- 1.7 0.9 +/- 1.7

-0.1 +/- 2.1 E-11 Funk Dairy Farm 08-13-08 EMI-4253

-0.4 +/- 1.1 1.0 +/- 0.4 0.01 +/- 0.13 1455 +/- 97

-0.4 +/- 1.6

-1.3 +/- 2.0

-0.6 +/- 1.4

-0.2 +/- 2.0 11-12-08 EMI-6456

-0.6 +/- 1.2 1.2 +/- 0.4

-0.17 +/- 0.15 1349 +/- 107

-0.3 +/- 1.5 0.1 +/- 1.6 0.5 +/- 1.0 0.4 +/- 2.0 09-10-08 EMI-4862

-1.2 +/- 0.9 1.1 +/- 0.3 0.03 +/- 0.11 1387 +/- 99 0.0 +/- 1.7 0.6 +/- 1.9

-3.2 +/- 1.4 0.4 +/- 1.9 12-10-08 EMI-6915

-0.6 +/- 0.9 1.1 +/- 0.4

-0.08 +/- 0.19 1430 +/- 100 /

-0.1 +/- 1.8

-0.2 +/- 1.9 1.4 +/- 1.8 /

0.2 +/- 2.2 '

Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 12

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCi/L)

E-21 Strutz Dairy Farm Required LLD Collection Date Lab Code Sr-89 Sr-90 01-09-08 EMI-101 0.0 +/- 0.8 0.5 +/- 0.3 0.21 +/- 0.25 02-13-08 EMI-538 0.6 +/- 1.0 0.4 +/- 0.4 0.02 +/- 0.12 03-12-08 EMI-1006 0.4 +/- 0.8 0.5 +/- 0.3 0.07 +/- 0.24 1-131 5.0 1.0 0.5 5.0 5.0 5.0 15.0 K-40 Cs-134 Cs-1 37 Ba-La-140 Co-60 1357 +/-

1.0 +/-

0.4 +/-

0.2 +/-

-2.0 +/-

123 1.6 2.1 2.3 2.4 1491 +/- 111 1452 +/- 113 0.3 +/- 2.5

-2.1 +/- 2.3

-3.6 +/- 2.6

-1.3 +/- 2.7 1.6 +/- 1.9

-2.5 +/- 2.2 0.9 +/- 2.5

-1.7 +/- 2.0 05-14-08 06-11-08 EMI-2366 EMI-2905 0.1 +/- 0.8 0.2 +/- 0.8 0.3 +/- 0.3 0.5 +/- 0.3 Required LLD Collection Date Lab Code Sr-89 Sr-90 04-09-08 EMI-1481 0.0 +/- 1.0 0.7 +/- 0.4

-0.16 +/- 0.16 1-131

-0.09 +/- 0.16 K-40 Cs-1 34 Cs-137 Ba-La-140 Co-60 1428 0.4 0.9 0.2

-1.4

+/-

+/-

112 1.6 1.9 1.8 1.9 1358

-3.2 0.9

-0.1

-1.7

+/-

+/-

+/-

+/-

+/-

ill 2.4 2.5 1.7 2.3 0.09 +/- 0.14 1406 +/- 113

-0.1 +/- 1.6 0.1 +/- 1.9 0.7 +/- 1.6 1.1 +/- 2.0 5.0 1.0 0.5 5.0 5.0 5.0 15.0 13

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCi/L)

Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-134 Cs-137 Ba-La-140 Co-60 Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-134 Cs-137 Ba-La-140 Co-60 E-21 Strutz Dairy Farm 07-09-08 08-13-08 EMI-3446 EMI-4254 0.0 +/- 0.8

-0.4 +/- 0.8 0.6 +/- 0.3 0.5 +/- 0.3 0.00 +/- 0.19 0.17 +/- 0.19 1369 +/- 94 1349 +/- 89 0.4 +/- 1.2 0.0 +/- 1.2 0.3 +/- 1.5 1.1 +/- 1.5 0.9 +/- 1.3

-0.2 +/- 1.3 0.0 +/- 1.8 0.8 +/- 1.5 10-08-08 11-12-08 EMI-5494 EMI-6457

-2.1 +/- 1.0 0.5 +/- 1.0 1.3 +/- 0.4 0.3 +/- 0.3 0.00 +/- 0.14

-0.04 +/- 0.15 1478 +/- 113 1482 +/- 110 0.1 +/- 1.5 0.3 +/- 1.8 1.3 +/- 1.9 0.3 +/- 2.3

-0.5 +/- 1.7 0.1 +/- 1.6

-1.1 +/- 2.1 1.0 +/- 2.4 09-10-08 EMI-4863 0.5 +/- 0.9 0.4 +/- 0.3 0.06 +/- 0.11 1455 +/- 111 0.6 +/- 1.4 0.1 +/- 1.6

-0.8 +/- 2.0 1.0 +/- 1.6 12-10-08 EMI-6916

-0.4 +/- 0.8 0.5 +/- 0.3 3 0.10 +/- 0.15 /

1496 +/- 107 /

1.5 +/- 1.6,

-0.1 +/- 2.2 0.3 +/- 1.4 1.0 +/- 1.8,

Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 14

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCi/L)

Collection Date Lab Code Sr-89 Sr-90 1-131 01-09-08 EMI-102

-1.5 +/- 1.0 1.6 +/- 0.4 0.04 +/- 0.20 1309 +/- 104 0.6 +/- 1.5 0.1 +/- 1.8 0.7 +/- 0.9 0.4 +/- 1.8 E-40 Barta 02-13-08 EMI-539 0.0 +/- 1.0 1.1 +/- 0.4

-0.01 +/- 0.13 03-12-08 EMI-1008

-0.5 +/- 0.9 1.0 +/- 0.3

-0.06 +/- 0.16 5.0 1.0 0.5 5.0 5.0 5.0 15.0 Required LLD K-40 Cs-134 Cs-137 Ba-La-140 Co-60 1310 +/-

-0.1 1 1.0+

-3.2 +/-

1.1 +

109 1.6 1.8 1.9 1.5 1430

-2.7

-2.1

-1.7

-2.9

+

+

+

+

+

113 2.9 2.8 2.0 2.6 Required LLD Collection Date Lab Code Sr-89 Sr-90 04-09-08 EMI-1482

-1.2 + 1.1 1.3 + 0.4

-0.03 + 0.20 05-14-08 06-11-08 EMI-2367 EMI-2906

-0.8 +/- 1.3 1.2 +/- 0.5 0.01 +/- 0.24

-1.8 +/- 1.0 1.8 +/- 0.4 1-131 K-40 Cs-134 Cs-1 37 Ba-La-140 Co-60 1424 +/-

-0.8 +/-

-2.0 +/-

1.7 +/-

0.1 +

118 1.9 2.6 2.2 2.5 1467 +/-

0.2 +/-

0.6 +/-

2.3 +

-0.1 +

117 1.6 1.9 1.2 1.9

-0.03 +/- 0.13 1416 +/- 113

-0.5 +/- 2.2

-2.3 +/- 2.7

-1.6 +/- 2.3

-1.7 +/- 2.1 5.0 1.0 0.5 5.0 5.0 5.0 15.0 15

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCi/L)

E-40 Barta Required LLD Collection Date Lab Code Sr-89 Sr-90 07-09-08 EMI-3447 0.5 +/- 0.9 0.8 +/- 0.3 0.20 +/- 0.22 08-13-08 EMI-4255

-0.3 +/- 1.1 0.9 +/- 0.4 0.19 +/- 0.18 1390 +/- 92

-1.0 +/- 1.4 0.6 +/- 1.6

-0.4 +/- 1.8 0.1 +/- 1.7 09-10-08 EMI-4864 0.4 +/- 0.8 0.7 +/- 0.3 0.07 +/- 0.17 1-131 5.0 1.0 0.5 5.0 5.0 5.0 15.0 K-40 Cs-134 Cs-137 Ba-La-140 Co-60 1412 +/-

-1.1 +/-

0.2 +/-

-0.7 +/-

-0.1 +/-

96 1.6 2.1 1.5 1.8 1387 +/-

0.0 +/-

0.6 +/-

-3.2 +/-

0.4 +/-

99 1.7 1.9 1.4 1.9 Required LLD Collection Date Lab Code 10-08-08 EMI-5495

-1.2 +/- 1.0 1.4 +/- 0.4 0.04 +/- 0.14 Sr-89 Sr-90 1-131 11-12-08 EMI-6458

-0.7 +/- 1.2 1.3 +/- 0.4 0.10 +/- 0.21 1313 +/- 98

-0.6 +/- 1.7 0.8 +/- 2.0

-0.7 +/- 1.8 1.8 +/- 1.7 EMI-6917

-0.4 +/- 0.8 0.8 +/- 0.3 r 0.03 +/- 0.15 12-10-09 K-40 Cs-1 34 Cs-137 Ba-La-140 Co-60 1292

-0.2 1.3

-0.2 0.1

+

+/-

+/-

+/-

110 1.4 1.9 1.4 1.9 1451

-0.5 0.8

-2.6

-0.3

+ 99

+/- 1.6

+/- 1.8

+/- 1.5

+ 2.0/

5.0 1.0 0.5 5.0 5.0 5.0 15.0 Sr-89 Annual Mean + s.d.

Sr-90 Annual Mean + s.d.

1-131 Annual Mean + s.d.

K-40 Annual Mean + s.d.

Cs-134 Annual Mean + s.d.

Cs-137 Annual Mean + s.d.

Ba-La Annual Mean + s.d.

Co-60 Annual Mean + s.d.

-0.5 +/- 0.7 0.9 +/- 0.4 0.02 +/- 0.11 1390 +/- 64

-0.5 +/- 1.1

-0.1 +/- 1.2

-0.3 +/- 1.7 0.1 +/- 1.3 16

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN WELL WATER SAMPLES, E-10 (Quarterly Collections)

Units: pCi/L 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Req.

Annual LLD Mean s.d Collection Date 01-17-08 04-11-08 07-17-08 10-15-08 Lab Code EWW-193 EWW-1604 EWW-3701 EWW-5686 Gross Beta 0.0 +/- 0.9 1.5 +/- 0.5 1.1 +/- 1.2 0.9 +/- 0.9 4.0 0.9 +/- 0.6 H-3 66.7 +/- 83.5 55.5 +/- 81.9 14.9 +/- 74.4 10.8 +/- 85.1 500 37.0 +/- 28.3 Sr-89 0.1 +/- 0.6

-0.3 +/- 0.6

-0.1 +/- 0.6 0.0 +/- 0.7 5.0

-0.1 +/- 0.2 Sr-90 0.1 +/- 0.3 0.2 +/- 0.2 0.0 +/- 0.2 0.1 +/- 0.3 1.0 0.1 +/- 0.1 1-131 0.14 +/- 0.3 0.00 +/- 0.15 0.05 +/- 0.14 0.13 +/- 0.16 0.5 0.08 +/- 0.07 Mn-54 0.1 +/- 2.4

-0.3 +/- 1.5

-2.0 +/- 2.2 0.0 +/- 1.8 10

-0.5 +/- 1.0 Fe-59 4.6 +/- 4.8 2.3 +/- 2.5

-4.7 +/- 4.6

-0.4 +/- 2.7 30 0.5 +/- 4.0 Co-58

-1.1 +/- 2.5

-1.1 +/- 1.6

-1.3 +/- 2.4

-1.4 +/- 1.4 10

-1.2 +/- 0.2 Co-60 0.6 +/- 2.8 0.9 +/- 1.4 0.7 +/- 2.2 0.5 +/- 1.7 10 0.7 +/- 0.2 Zn-65 2.4 +/- 4.7

-0.2 +/- 2.6

-5.9 +/- 5.2 1.7 +/- 2.6 30

-0.5 +/- 3.8 Zr-Nb-95

-0.3 +/- 1.9

-5.4 +/- 2.0

-1.6 +/- 2.2

-2.1 +/- 1.7 15

-2.4 +/- 2.2 Cs-134

-0.1 +/- 2.1 0.3 +/- 1.3

-0.2 +/- 2.4

-0.6 +/- 1.7 10

-0.2 +/- 0.4 Cs-137

-0.5 +/- 2.1

-0.1 +/- 1.7

-0.9 +/- 2.8

-1.4 +/- 2.0 10

-0.7 +/- 0.6 Ba-La-140

-0.4 +/- 2.7

-0.8 +/- 1.9

-8.5 +/- 3.5 1.7 +/- 1.8 15

-2.0 +/- 4.5 Ru-103 0.5 +/- 2.2 1.0 +/- 1.5

-2.2 +/- 2.5

-0.6 +/- 1.5 30

-0.3 +/- 1.4 17

POINT BEACH Lake water, analyses for gross beta, iodine-131 and gamma emitting isotopes.

Location: E-01 (Meteorological Tower)

Collection:

Monthly composites Units: pCi/L Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Ru-103 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Ru-103 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Ru-103 ELW-188 01-16-08 2.6 +/- 1.1 0.01 +/- 0.18

-0.5 +/- 15.7

-0.4 +/- 1.7 3.5 +/- 3.2 0.9 +/- 1.7 0.1 +/- 1.9

-4.7 +/- 4.2

-1.3 +/- 2.1

-1.2 +/- 1.9

-1.3 +/- 2.0 1.7 +/- 2.0

-1.1

+/- 1.7 ELW-2395 05-15-08 1.4 +/- 0.5

-0.07 +/- 0.16 34.8 +/- 24.1

-1.7

+/- 3.0 2.1

+/- 5.0 2.8 +/- 2.7

-1.5 +/- 3.1

-1.4 +/- 7.0

-0.7 +/- 2.6 0.1 +/- 2.8

-1.3 +/- 3.1

-0.8 +/- 4.1 1.2 +/- 2.7 ELW-4931 09-12-08 2.0 +/- 1.0

-0.24 + 0.17

-15.2 + 23.4 2.3 + 3.0

-1.1

+/- 6.2 2.1 +/- 2.4 1.9 +/- 3.1 0.8 +/- 6.3

-2.3 +/- 2.9

-0.6 +/- 3.1 3.0 +/- 3.1

-2.4 +/- 3.0 4.0 +/- 2.8 ELW-574 02-14-08 1.3 +/- 0.6

-0.02 +/- 0.20

-10.4 +/- 15.4

-1.2 +/- 1.8

-3.8 +/- 3.6

-0.6 +/- 1.8 0.7 +/- 1.9 2.3 +/- 3.4 1.0 +/- 1.9

-2.8 +/- 2.1 0.6 +/- 2.0 4.4 +/- 2.0

-0.9 +/- 1.9 ELW-2939 06-12-08 1.5 +/- 0.6 0.02 +/- 0.21 3.4 +/- 11.2

-0.6 +/- 1.5

-1.5 +/- 2.7

-0.4 +/- 1.5 0.3 +/- 1.4

-2.3 +/- 2.4 1.0 +/- 1.1 0.1 +/- 1.1

-0.2 +/- 1.2 0.1 +/- 1.6

-0.2 +/- 1.2 ELW-5682 10-15-08 2.6 +/- 1.1 0.17 +/- 0.18 4.1 +/- 11.1 0.2 +/- 1.3

-0.3 +/- 2.6

-1.2 +/- 1.3

-0.4 +/- 1.4

-1.9 +/- 3.1

-0.9 +/- 1.3

-0.1 +/- 1.2 0.8 +/- 1.5

-1.3 +/- 1.5

-0.2 +/- 1.2 ELW-1028 03-13-08 1.4 +/- 0.9 0.02 +/- 0.16 8.6 +/- 18.6

-0.3 +/- 2.0 2.0 +/- 3.8 0.6 +/- 1.8 0.5 +/- 2.0

-4.0 +/- 3.9 0.2 +/- 2.2

-2.9 + 2.4

-0.3 + 2.1 1.2 + 2.4

-1.3 + 2.2 ELW-3697 07-16-08 2.7 +/- 1.0

-0.23 +/- 0.19

-0.9 +/- 14.4 1.1 +/- 1.4

-3.3 +/- 3.2

-0.8 +/- 1.4

-1.3

+/- 1.7

-1.5 +/- 2.7

-0.7 +/- 1.8

-1.2 +/- 1.8 1.3 +/- 2.0 0.1 +/- 1.3

-1.0

+/- 1.5 ELW-6494 11-12-08 2.0 +/- 1.0 0.16 +/- 0.19

-8.9 +/- 18.1 1.9 +/- 2.2

-6.3 +/- 4.6 0.7 +/- 2.0

-0.4 +/- 2.3 0.2 +/- 4.7

-0.1

+/- 2.3

-2.3 +/- 1.9 1.4 +/- 2.3

-4.9 +/- 3.0

-1.8

+/- 2.4 ELW-1598 04-11-08 1.4 +/- 0.9 0.06 +/- 0.18

-14.2

+/- 16.1 0.4 +/- 1.8

-0.8 +/- 3.2

-0.9 +/- 1.6 0.4 +/- 1.7 2.0 +/- 2.8

-1.5

+/- 1.9

-1.3

+/- 1.9

-1.1

+/- 2.1 0.0 +/- 1.6

-0.1 +/- 1.8 ELW-4371 08-14-08 1.4 +/- 0.6 0.06 +/- 0.14 5.1 +/- 13.8 0.1

+/- 1.5 0.6 +/- 2.7

-0.4 +/- 1.6

-0.4 +/- 1.7 0.6 +/- 3.0 0.1

+/- 1.9 0.3 +/- 1.6

-0.7 +/- 1.9 0.3 +/- 1.7

-1.4

+/- 1.5 NS/

Req. LLD 4.0 0.5 10 30 10 10 30 15 10 i0 15 30 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 a "NS" = No sample; see Table 2.0, Listing of Missed Samples.

18

POINT BEACH Lake water, analyses for gross beta, iodine-131 and gamma emitting isotopes.

Location: E-05 (Two Creeks Park)

Collection: Monthly composites Units: pCi/L Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Ru-103 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 Ru-103 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Ru-1 03 ELW-189 01-16-08 2.5 1 i.0 0.03 + 0.18 1.6 +/- 21.0 1.1 +/-2.7

-1.4

+/- 5.2 0.3 + 2.6

-1.4 + 2.8

-5.0 + 5.6 1.2 + 2.5 1.9 + 2.4

-1.8 + 2.8 1.7 + 3.7

-1.2 + 2.4 ELW-2396 05-15-08 0.5 + 0.5 0.03 +/- 0.15 3.3 +/- 15.4 0.5 + 2.0 0.1 +3.6 0.5 +/- 1.9

-0.6 +/- 1.7

-2.3 +/- 3.9 0.3 +/- 2.0

-2.5 + 2.0 0.5 + 2.2

-2.8 +/- 2.1

-0.9 + 2.0 ELW-4932 09-12-08 3.1 + 1.0

-0.11 + 0.18 4.0 + 21.7 2.1 +2.6 3.1 +/- 4.8 1.4 + 2.4

-1.3 +/- 2.7

-4.6 +/- 5.8 0.7 +/- 2.7

-1.7 + 2.7

-0.8 + 3.1 3.5 +/- 3.1

-0.2 + 2.5 ELW-715 02-21-08 1.3 +/- 0.6

-0.23 +/- 0.17

-2.0 +/- 12.6

-0.6 +/- 1.8 1.6 + 3.0 0.4 + 1.6 1.0 + 1.9 0.9 +/- 3.2 0.1 +/- 1.8 0.6 +/- 1.4 0.1 + 1.6

-1.2 +/- 2.3

-0.2 +/- 1.5 ELW-2941 06-12-08 1.7 +/- 0.6

-0.06 +/- 0.17

-22.5 +/- 22.4

-0.9 +/- 2.9 0.2 +/- 5.3

-0.2 +/- 3.1 0.7 +/- 3.2

-3.1 +/- 5.6

-0.7 +/- 2.8

-1.0 +/- 2.5

-1.3 +/- 3.0 3.2 +/- 3.4 0.5 +/- 3.0 ELW-5683 10-15-08 1.0 +/- 0.9 0.05 +/- 0.17 4.3 +/- 11.4 1.0 +/- 1.4 1.6 +/- 2.3

-0.5 +/- 1.3

-0.8 +/- 1.6

-2.0 +/- 2.9 0.1 +/- 1.5 0.2 +/- 1.5 2.3 +/- 1.6

-0.8 +/- 1.3 0.1 +/- 1.5 ELW-1030 03-13-08 0.0 +/- 0.9 0.12 +/- 0.19

-16.5

+/- 16.4 2.8 + 1.7

-0.3 +/- 3.2

-1.0 + 1.7 0.6 +/- 1.9

-2.2 +/- 4.1

-0.8 +/- 1.8 0.3 + 1.7 0.1

+/- 2.1

-0.1 + 2.0

-1.5

+ 1.9 ELW-3698 07-17-08 2.5 +/- 1.0

-0.10 +/- 0.14

-6.3 +/- 17.9 0.2 +/- 2.5

-0.6 +/- 4.6

-0.2 +/- 2.3

-0.6 + 2.1

-3.0 +/- 4.9

-1.2 + 2.2

-2.0 +/- 2.2

-1.5 +/- 2.7 3.2 +/- 2.3

-0.6 + 2.4 ELW-6495 11-12-08 3.4 +/- 1.0 0.00 +/- 0.17 1.9 +/- 17.0

-0.6 +/- 1.5

-2.8 +/- 3.5 1.6 +/- 1.7 0.6 +/- 1.8 2.1 +/- 4.0 0.7 + 1.7 0.0 +/- 2.0

-0.9 _ 2.0

-2.3

_ 2.0

-1.8 + 2.0 ELW-1599 04-11-08 2.0 +/- 0.5 0.15 +/- 0.18 9.6 +/- 16.7

-0.3 +/- 1.7

-2.3 +/- 3.1

-0.1

+/- 1.6 0.5 +/- 1.8 1.3 +/- 3.3

-1.1

+/- 1.7

-1.6 +/- 1.5

-1.3

+/- 2.1

-0.9 +/- 2.1

-0.2 +/- 1.7 ELW-4372 08-14-08 0.7 +/- 0.5 0.32 +/- 0.26 9.2 +/- 25.0

-0.3 +/- 2.7 2.4 +/- 6.2 2.8 +/- 2.4 1.5 +/- 2.9 0.1 +/- 6.9 0.2 +/- 2.9

-3.6 +/- 3.0 4.8 +/- 3.0

-2.1

+/- 3.2

-0.5 +/- 2.7 ELW-7063 12-17-08 2.6 +/- 1.0 /

0.01 + 0.13

-8.1

+ 10.3

-0.6 +/- 1.3 0.9 +/- 2.3

-0.9 +/- 1.2

-0.2 +/- 1.2 0.5 +/- 2.3

-0.7 +/- 1.1 0.2 +/- 1.0 0.8 +/- 1.2/

-0.8 + 1.6

-0.9 + 1.2 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 19

POINT BEACH Lake water, analyses for gross beta, iodine-131 and gamma emitting isotopes.

Location: E-06 (Coast Guard Station)

Collection:

Monthly composites Units:

pCi/L Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 Ru-103 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 Ru-103 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Ru-103 ELW-190 01-16-08 2.8 +/- 1.1 0.08 +/- 0.18

-1.3 +/- 9.4 0.4 +/- 1.2

-2.2 +/- 2.0

-0.2 +/- 1.1 0.1 +/- 1.2 0.6 +/- 2.1

-0.7 +/- 1.3 0.8 +/- 0.9 0.3 +/- 1.1

-2.7 +/- 1.6 0.0 +/- 1.2 ELW-2397 05-15-08 1.3 +/- 0.5

-0.02 +/- 0.18 3.2 +/- 23.1

-1.5 +/- 3.3 3.7 +/- 6.1

-0.5 +/- 3.1

-1.2 +/- 4.0

-6.0 +/- 5.9 1.7 +/- 2.6

-0.4 +/- 2.8

-1.2 +/- 3.3 4.3 +/- 4.0

-0.1 +/- 3.1 ELW-4933 09-12-08 1.9 +/- 1.0

-0.12 +/- 0.20

-2.7 +/- 15.8 0.7 +/- 2.0 1.5 +/- 3.3 1.7 +/- 1.8

-0.2 +/- 2.0

-0.7 +/- 4.4

-2.8 +/- 1.9 0.2 +/- 1.8 0.1 +/- 2.2

-0.3 +/- 2.8 1.0 +/- 1.9 ELW-716 02-21-08 0.6 +/- 0.5

-0.02 +/- 0.20 1.8 +/- 30.0

-1.3 +/- 2.9

-1.7 +/- 6.1

-1.6 +/- 3.6

-0.3 +/- 4.4 0.4 +/- 6.5 1.3 +/- 3.3

-2.6 +/- 2.8 0.3 +/- 3.4 3.6 +/- 3.0 0.7 +/- 3.2 ELW-2942 06-12-08 1.3 +/- 0.5 0.07 +/- 0.14 7.8 +/- 12.3 0.5 +/- 1.5

-1.1

+/- 2.4

-0.3 +/- 1.8 0.1 +/- 1.3 1.5 +/- 2.8

-0.3 +/- 1.3 0.3 +/- 1.4

-0.1

+/- 1.5 0.7 +/- 2.2

-1.0 +/- 1.5 ELW-5684 10-15-08 1.3 +/- 1.0

-0.07 +/- 0.19

-7.6 +/- 12.3

-1.6

+/- 1.6 2.2 +/- 3.0

-0.7 +/- 1.5

-0.7 +/- 1.8 1.3 +/- 3.1

-0.9 +/- 1.4 0.5 +/- 1.2 0.5 +/- 1.8 0.3 +/- 1.4

-1.0 +/- 1.4 ELW-1031 03-13-08 0.8 +/- 0.8

-0.01

+/- 0.18 13.1

+/- 17.7 2.5 +/- 1.9

-2.5 +/- 3.7 1.0 +/- 1.8 1.1

+/- 1.8 2.5 +/- 3.1

-1.4 +/- 2.2 0.8 +/- 2.1

-0.1

+/- 2.5

-1.2 +/- 1.9 0.2 +/- 2.0 ELW-3699 07-17-08 1.5 +/- 1.0 0.09 +/- 0.14 1.9 +/- 18.5

-1.1

+/- 1.9 2.7 +/- 3.5 1.2 +/- 1.6

-1.3 +/- 1.8

-0.4 +/- 3.9 1.6 +/- 1.6

-0.1

+/- 2.0

-0.9 +/- 2.1 1.3 +/- 2.4

-1.8 +/- 2.1 ELW-6496 11-12-08 1.4 +/- 1.0 0.01

+/- 0.16

-0.2 +/- 17.4 0.7 +/- 1.7

-2.0 +/- 4.0

-0.2 +/- 1.5

-0.7 +/- 1.8

-1.0 +/- 3.7

-3.2 +/- 2.2 0.3 +/- 1.9

-0.9 +/- 2.0

-1.0

+/- 2.0

-2.8 +/- 2.2 ELW-1600 04-11-08 1.0 +/- 0.4

-0.03 +/- 0.14

-3.5 +/- 15.3 1.7 +/- 1.7

-1.0

+/- 3.1

-2.1

+/- 1.8

-1.1

+/- 1.5

-1.5

+/- 3.1 0.4 +/- 1.6

-2.1

+/- 1.9 0.5 +/- 2.1 1.2 +/- 1.7

-1.6 +/- 1.8 ELW-4373 08-14-08 0.6 +/- 0.5

-0.04 +/- 0.17

-14.3

+/- 12.5

-0.9 +/- 1.6

-1.8

+/- 2.7 0.8 +/- 1.3

-0.5 +/- 1.5

-1.1

+/- 2.7

-0.5 +/- 1.4 1.3 +/- 1.5 0.1 +/- 1.6 1.7 +/- 1.8 0.0 +/- 1.5 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 NSa a "NS" = No sample; see Table 2.0, Listing of Missed Samples.

20

POINT BEACH Lake water, analyses for gross beta, iodine-131 and gamma emitting isotopes.

Location: E-33 (Nature Conservancy)

Collection:

Monthly composites Units:

pCi/L Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Ru-1 03 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Ru-1 03 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-137 Ba-La-140 Ru-103 ELW-192 01-16-08 3.4 +/- 1.1 0.05 +/- 0.14 13.3 +/- 18.2 0.4 +/- 1.9 1.6 +/- 4.5 2.3 +/- 1.9 0.8 +/- 2.6

-6.1 +/- 6.2 1.5 +/- 2.0

-4.5 +/- 2.7 0.4 +/- 2.7

-2.4 +/- 2.1

-0.1 +/- 2.1 ELW-2398 05-15-08 1.1 +/- 0.6

-0.07 +/- 0.14 1.7 +/- 16.3

-0.1

+/- 1.6 0.6 +/- 3.1 0.2 +/- 1.7 0.8 +/- 1.7

-1.3 +/- 3.6 0.2 +/- 2.0

-0.1 +/- 2.0

-0.1 +/- 1.9 1.6 +/- 2.1

-3.7 +/- 2.0 ELW-4934 09-12-08 3.2 +/- 2.0 0.06 +/- 0.19 1.7 +/- 13.2 0.4 +/- 1.6 0.1 +/- 3.0 1.7 +/- 1.2 0.6 +/- 1.8

-0.5 +/- 3.1 0.4 +/- 1.5 0.2 +/- 1.4 1.2 +/- 1.6

-3.2 +/- 2.1 1.2 +/- 1.5 ELW-575 02-14-08 1.4 +/- 0.5

-0.04 +/- 0.17

-1.8 +/- 13.9 0.9 +/- 1.6

-1.8 + 2.9

-1.8 + 1.7

-0.5 +/- 1.4 1.6 + 2.8 1.8 +/- 1.9

-0.2 +/- 1.4 0.6 + 1.8

-0.6 +/- 2.2 0.4 +/- 1.8 ELW-2943 06-12-08 1.8 +/- 0.6 0.12 +/- 0.15

-1.6 +/- 13.5 0.1 +/- 1.5 0.5 +/- 2.6

-0.9 +/- 1.7

-0.6 +/- 1.5

-0.6 +/- 3.1

-0.7 +/- 1.5

-0.3 +/- 1.6

-0.1 +/- 1.8 2.6 +/- 1.8

-1.1

+/- 1.5 ELW-5685 10-15-08 2.1 +/- 0.9 0.10 +/- 0.23 10.9 +/- 13.1

-0.2 +/- 1.5 3.2 +/- 2.6

-0.6 +/- 1.6 1.0 +/- 1.7 0.1 +/- 3.2 0.5 +/- 1.4 0.1

+/- 1.6 0.1 +/- 1.5

-3.6 +/- 2.4 0.0 +/- 1.5 ELW-1032 03-13-08 0.8 +/- 0.9 0.03 +/- 0.15 7.7 +/- 13.4 0.6 +/- 1.5 0.1

+/- 2.8 0.1 +/- 1.7 1.0 +/- 1.3 3.1

+/- 3.2 1.1

+/- 1.6

-0.2 +/- 1.4 0.0 +/- 1.5

-2.1 +/- 1.9

-0.9 +/- 1.5 ELW-3700 07-17-08 1.7 +/- 0.9 0.05 +/- 0.15 6.6 +/- 12.9 0.7 +/- 1.5 0.5 +/- 3.0

-0.3 +/- 1.6

-1.4

+/- 1.8

-0.5 +/- 2.9

-0.8 +/- 1.6

-0.6 +/- 1.7

-0.1 +/- 1.9

-0.7 +/- 2.1 0.6 +/- 1.6 ELW-6497 11-12-08 2.2 +/- 0.4

-0.04 +/- 0.16 5.1 +/- 16.1 0.1

+/- 2.0 4.5 +/- 3.6 1.0 +/- 2.2 1.0 +/- 1.9 0.9 +/- 4.0 0.4 +/- 2.1

-0.2 +/- 1.9

-0.9 +/- 2.4

-0.3 +/- 2.8

-0.3 +/- 2.1 ELW-1601 04-11-08 1.9 +/- 0.5

-0.04 +/- 0.17

-8.0 +/- 13.8

-1.5 +/- 1.7 1.0 +/- 3.1 0.6 +/- 1.7 0.5 +/- 1.7

-3.1 + 3.4

-1.7 + 1.7

-1.3

+/- 1.4 0.2 +/- 1.8

-0.4 +/- 2.3

-1.3 +/- 1.7 ELW-4374 07-17-08 1.1

+/- 0.6 0.11 +/- 0.20

-6.8 +/- 16.3

-1.9 +/- 2.1

-1.9 +/- 4.1 1.5 +/- 2.1

-0.9 +/- 2.2

-3.3 +/- 4.9

-1.5 +/- 2.2

-0.2 +/- 2.0

-0.7 +/- 2.1

-0.4 +/- 2.4

-0.9 +/- 2.3 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 All locations ELW-7064 Annual 12-17-08 Req. LLD Mean s.d.

1.5 +/- 1.0/

4.0 1.6 +/- 0.9

-0.07 +/- 0.14 0.5 0.01 +/- 0.10 4.1

+/- 10.1 0.3 +/- 9.4 0.1 +/- 1.2 10 0.1 +/-1.1

-0.8 +/- 2.2 30 0.0 +/- 2.2

-0.1

+/- 1.1 10 0.2 +/- 1.1 0.7 +/- 1.3' 10 0.0 +/- 0.8 1.7 +/- 2.3/

30

-0.8 +/- 2.3

-0.8 +/- 1.3 15

-0.2 +/- 1.1

-0.7 +/- 1.3 10

-0.6 +/- 1.3

-0.8 +/- 1.4 10 0.0 +/- 1.2

-1.7 +/- 1.4 15

-0.1 +/- 2.1

-1.4 +/- 1.2 30

-0.5 +/- 1.2 21

POINT BEACH NUCLEAR PLANT Lake water, analyses for tritium, strontium-89 and strontium-90.

Collection: Quarterly composites of weekly grab samples Units: pCi/L Location E-01 (Meteorological Tower)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code ELW-1 097 ELW-2953 ELW-4949 ELW-7304 H-3 132 +/- 101 56 +/- 88

-19 +/- 96 88 +/- 75 Sr-89 0.11 +/- 0.69 0.34 +/- 1.03 0.00 +/- 0.57

-0.11 +/- 1.29 Sr-90 0.26 +/- 0.27 0.25 +/- 0.34 0.23 +/- 0.28 0.36 +/- 0.32 Location E-05 (Two Creeks Park)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code ELW-1098 ELW-2954 ELW-4950 ELW-7305 H-3 116 +/- 88 135 +/- 92

-37 +/- 95 65 +/- 73 Sr-89

-0.26 +/- 0.70 0.55 +/- 0.94

-0.06 +/- 0.58 0.53 +/- 0.68 Sr-90 0.45 +/- 0.28 0.35 +/- 0.30 0.51 +/- 0.29 0.57 +/- 0.27 Location E-06 (Coast Guard Station)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code ELW-1099 ELW-2955 ELW-4951 ELW-7306 H-3 72 +/- 86 84 +/- 89 15 +/- 98 68 +/- 74 Sr-89 0.20 +/- 0.73 1.04 +/- 1.18 0.63 +/- 0.75

-0.90 +/- 1.23 Sr-90 0.33 +/- 0.29 0.51 +/- 0.41 0.28 t 0.28 0.40 +/- 0.33 Location E-33 (Nature Conservancy)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code ELW-1100 ELW-2956a ELW-4952 ELW-7307 H-3 28 +/- 96 1251 +/- 132 72 +/-100 58 +/- 73 Sr-89 0.14 +/- 0.73 0.16 +/- 0.72

-0.05 +/- 0.52 0.05 +/- 0.72 Sr-90 0.22 +/- 0.28 0.13 +/- 0.23 0.32 +/- 0.26 0.25 +/- 0.29 aTritium repeated with a result of 1383+/-127 pCiIL.

Results of monthly samples; April: 4057+/-189 pCi/L; May -73+/-77 pCi/L; June -129+/-79 pCi/L Tritium Annual Mean + s.d.

Sr-89 Annual Mean + s.d.

Sr-90 Annual Mean + s.d.

137 +/-301 0.15 +/- 0.43 0.34 +/- 0.12 Note: pages 23 and 24 are intentionally left out.

22

POINT BEACH NUCLEAR PLANT Fish, analyses for gross beta and gamma emitting isotopes.

Location: E-13 Collection: 3x / year Units:

pCi/g wet Sample Description and Concentration Required LLD Collection Date Lab Code Type Ratio (wet/dry wt.)

Gross Beta K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-134 Cs-137 Ru-103 Collection Date Lab Code Type Ratio (wet/dry wt.)

Gross Beta 03-11-08 EF-954 Brown Trout 3.92 2.80 +/- 0.12 1.63 +/- 0.38

-0.005 +/- 0.013

-0.012 +/- 0.025

-0.002 +/- 0.012 0.008 +/- 0.014 0.016 +/- 0.020

-0.008 +/- 0.010 0.015 +/- 0.012

-0.011 +/- 0.010 03-11-08 EF-955 Smallmouth Bass 4.59 4.30 +/- 0.16 2.88 +/- 0.38 0.006 +/- 0.008

-0.004 +/- 0.018 0.005 +/- 0.010 0.002 +/- 0.010 0.009 +/- 0.017 0.010 +/- 0.009 0.007 +/- 0.011

-0.003 +/- 0.008 08-14-08 EF-4280 Lake Trout 4.58 3.19 +/- 0.08 03-11-08 EF-956 Catfish 2.94 4.02 +/- 0.13 3.05 0.004

-0.029 0.000 0.006 0.008

-0.011 0.070 0.005

+}

+

+.

+{

+{

+-

0.45 0.010 0.027 0.011 0.013 0.028 0.013 0.025 0.010 0.5 0.13 0.26 0.13 0.13 0.26 0.13 0.15 0.5 08-14-08 EF-4279 Brown Trout 3.60 4.27 +/- 0.10 3.07 +/- 3.07 08-14-08 EF-4281 Lake Trout 4.18 3.76 +/- 0.11 0.5 K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-134 Cs-1 37 Ru-1 03 2.12 +/- 0.48

-0.004 0.006 0.003 0.007

-0.024 0.007 0.038

-0.003

+ 0.008

+ 0.018

+/- 0.008

+/- 0.009

+/- 0.022

+ 0.006

+/- 0.014

+/- 0.007 0.000 0.040 0.010

-0.003

-0.016

-0.001 0.058 0.010

+

+

+/-

+

+

+

+

+

0.010 0.026 0.010 0.013 0.031 0.012 0.030 0.010 3.27 +/- 3.27

-0.001 +/- 0.007 0.006 +/- 0.016 0.002 +/- 0.008 0.006 +/- 0.010

-0.019 +/- 0.020

-0.011 +/- 0.008 0.019 +/- 0.011 0.001 +/- 0.007 0.13 0.26 0.13 0.13 0.26 0.13 0.15 0.5 NOTE: Pages 2,and 27 are intentionally left out.

25

POINT BEACH NUCLEAR PLANT Fish, analyses for gross beta and gamma emitting isotopes.

Location: E-13 Collection: 3x / year Units:

pCilg wet Sample Description and Concentration (pCi/g wet)

Required LLD Collection Date 12-18-08 12-18-08 Lab Code EF-7104 EF-7105 Annual Type Lake Trout Rainbow Trout Ratio (wet/dry wt.)

2.25 2.27 Mean s.d.

Gross Beta 3.84 +/- 0.15 4.34 +/- 0.16 3.82 +/- 0.56 0.5 K-40 2.52 +/- 0.36 "

3.01 +/- 0.43 /

2.69 +/- 0.56 Mn-54

-0.004 +/- 0.008

-0.001 +/- 0.010

-0.001 +/- 0.004 0.13 Fe-59 0.009 +/- 0.014

-0.008 +/- 0.020 0.001 +/- 0.020 0.26 Co-58

-0.002 +/- 0.007

-0.002 +/- 0.009 0.002 +/- 0.004 0.13 Co-60

-0.005 +/- 0.011 0.001 +/- 0.011 0.003 +/- 0.005 0.13 Zn-65

-0.001 +/- 0.019

-0.016 +/- 0.025

-0.005 +/- 0.015 0.26 Cs-134

-0.001 +/- 0.007 0.002 +/- 0.011

-0.002 +/- 0.008 0.13 Cs-137 0.033 +/- 0.015 0.025 +/- 0.012k 0.033 +/- 0.022 0.15 Ru-103

-0.007 +/- 0.007 0.011 +/- 0.009 0.000 +/- 0.008 0.5 NOTE: Page 27 is intentionally left out.

Note: Page 27 is intentionally left out.

26

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN SHORELINE SEDIMENT SAMPLES

.(Semiannual Collections)

Sample Description and Concentration (pCi/g dry)

Collection Date Lab Code 4/11/2008 ESS-1655 4/11/2008 ESS-1656 E-05 11.10 +/- 1.82 4/11/2008 Required ESS-1657 LLD E-06 Location E-01 Gross Beta 9.96 +/- 2.07 13.84 +/- 1.99 Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 0.021 6.27 0.036 0.041 0.11 0.13 0.32 0.16

+

+

+

+

+

+

+

+

0.054 0.42 0.015 0.014 0.11 0.023 0.13 0.048

-0.010 6.63 0.011 0.058 0.11 0.14 0.52 0.20

+

+-

0.080 0.60 0.013 0.024 0.022 0.033 0.17 0.080 0.042 8.57 0.035 0.049 0.10 0.11 0.24 0.11

+/- 0.062

+/- 0.52

+/- 0.019

+/- 0.024

+/- 0.017

+/- 0.027

+/- 0.14

+/- 0.059 2.0 0.15 Collection Date Lab Code Location 4/11/2008 ESS-1658 4/11/2008 ESS-1659 E-33 E-12 Gross Beta Be-7 K-40 Cs-1 37 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 25.60 +/- 2.70 0.031 +/- 0.062 5.54 +/- 0.40 0.014 +/- 0.010 0.046 +/- 0.015 0.15 +/- 0.019 0.13 +/- 0.029 0.25 +/- 0.15 0.16 +/- 0.048 14.58

+/- 1.99 0.068 +/- 0.058 8.53 +/- 0.52 0.015 +/- 0.010 0.044 +/- 0.020 0.11 +/- 0.018 0.10 +/- 0.029 0.19 +/- 0.15 0.12 +/- 0.048 2.0 0.15 28

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN SHORELINE SEDIMENT SAMPLES (Semiannual Collections)

Sample Description and Concentration (pCi/g dry)

Collection Date Lab Code 10/15/2008 ESS-5688 Location E-0 1 Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 11.05 + 2.11

-0.028 +/- 0.061 3.15 + 0.28 0.038 +/- 0.015 0.246 +/- 0.026 0.67 +/- 0.03 0.57 +/- 0.051 0.84 +/- 0.21 0.76 +/- 0.074 10/15/2008 ESS-5691 10/15/2008 ESS-5689 E-05 23.94 +/- 2.45 0.188 + 0.081 3.54 +/- 0.34 0.015 +/- 0.010 0.513 + 0.030 1.32 +/- 0.041 0.92 +/- 0.053 1.67 +/- 0.28 1.58 +/- 0.110 10/15/2008 ESS-5692 9.48 +/- 1.66 0.089 +/- 0.055 7.13 + 0.44 0.037 + 0.019 0.072 +/- 0.014 0.25 + 0.062 0.21 + 0.028 0.43 +/- 0.17 0.22 + 0.051 10/15/2008 ESS-5690 Required LLD 2.0 E-06 0.15 Collection Date Lab Code Annual Mean s.d.

Location E-12 E-33 Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 7.58 _ 1.46 0.077 0 0.054 4.30 + 0.34 0;031 + 0.016 0.104 + 0.019 0.33 +/- 0.068 0.19 +/- 0.030 0.47 +/- 0.17 0.31 +/- 0.049 11.47

+/-1.73 0.208 +/- 0.054 6.66 +/- 0.41 0.020 +/- 0.009 0.047 +/- 0.018 0.24 + 0.064 0.20 +/- 0.041 0.28 +/- 0.16 0.22 + 0.061 2.0 13.86 +/- 6.10 0.068 +/- 0.077 6.03 +/- 1.90 0.15 0.025 +/- 0.011 0.12 +/- 0.15 0.34 +/- 0.38 0.27 +/- 0.27 0.52 +/- 0.45 0.38 +/- 0.46 29

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN SOIL SAMPLES (Semiannual Collections)

Sample Description and Concentration (poi/g dry)

Collection Date Lab Code 5/28/2008 ESO-2565 5/28/2008 ESO-2566 E-02 32.15 +/- 2.29 5/28/2008 Required ESO-2567 LLD E-03 Location E-01 Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 27.55 +/- 2.24 0.026 +/- 0.074 14.80 +/- 0.69 0.14 +/- 0.026 0.16 +/- 0.025 0.50 +/- 0.085 0.29 +/- 0.039 0.90 +/- 0.24 0.48 +/- 0.086 5/28/2008 ESO-2568 0.587 18.97 0.084 0.21 0.74 0.45 1.00 0.74

+/- 0.21

+/- 0.82

+/- 0.025

+/- 0.029

+/- 0.089

+/- 0.048

+/- 0.27

+/- 0.13 15.43 +/- 1.89

-0.010 +/- 0.057 8.75 +/- 0.47 0.005 +/- 0.008 0.062 +/- 0.014 0.16 +/- 0.021 0.14 +/- 0.025 0.41 +/- 0.18 0.20 +/- 0.052 5/28/2008 ESO-2570 E-08 21.20 +/- 2.51 2.0 0.15 Collection Date Lab Code 5/28/2008 ESO-2569 E-06 20.91 +/- 2.08 Location E-04 Gross Beta Be-7 K-40 Cs-1 37 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 15.61 +/- 1.81 0.065 +/- 0.068 8.66 +/- 0.53 0.15 +/- 0.024 0.078 +/- 0.019 0.22 +/- 0.226 0.22 +/- 0.030 0.61 +/- 0.24 0.28 +/- 0.061 2.0 0.056 12.67 0.35 0.071 0.18 0.17 0.44 0.28

+/- 0.062

+/- 0.63

+/- 0.027

+/- 0.019

+/- 0.029

+/- 0.028

+/- 0.20

+/- 0.077

-0.011 11.10 0.046 0.089 0.21 0.10 0.39 0.28

+

+

+

+

+

+

+

+

0.061 0.54 0.022 0.022 0.028 0.031 0.19 0.067 0.15 Collection Date Lab Code 5/28/2008 ESO-2571 5/28/2008 ESO-2572 E-20 34.96 +/- 2.75 Location E-09 Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 38.31 +/- 2.86

-0.059 21.28 0.17 0.22 0.71 0.45 1.33 0.69

+/- 0.097

+/- 0.92

+/- 0.034

+/- 0.035

+/- 0.11

+/- 0.052

+/- 0.32

+/- 0.091 0.044 17.11 0.13 0.15 0.41 0.22 0.88 0.57

+/- 0.075

+/- 0.76

+/- 0.024

+/- 0.028

+/- 0.034

+/- 0.044

+/- 0.28

+/- 0.099 30

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN SOIL SAMPLES (Semiannual Collections)

Sample Description and Concentration (pCi/g dry)

Collection Date Lab Code 10/29/2008 ESO-6237 10/29/2008 ESO-6238 E-02 41.37 +/- 3.30 10/29/2008 ESO-6239 E-03 34.24 +/- 2.76 Required LLD Location E-01 Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 36.58 +/- 2.90 0.042 15.58 0.21 0.18 0.46 0.38 1.32 0.62

+

+

+

+

+

+

+

+

0.088 0.73 0.030 0.030 0.035 0.045 0.31 0.13 0.053 14.84 0.073 0.13 0.39 0.26 0.74 0.48

+

-+

+}

+r

+r

+r

-+

+"

0.074 0.70 0.023 0.025 0.033 0.043 0.26 0.11 0.198 19.07 0.25 0.22 0.78 0.47 1.31 0.83

+

+r

+r

+r

+

+r

+r

+r 0.084 0.85 0.034 0.034 0.103 0.067 0.28 0.12 2.0 0.15 Collection Date Lab Code 10/29/2008 ESO-6240 Location E-04 Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 Collection Date Lab Code 32.20 +/- 2.74 0.047 15.43 0.11 0.14 0.48 0.29 0.75 0.44

+/- 0.090

+/- 15.43

+/- 0.025

+/- 0.027

+/- 0.091

+/- 0.053

+/- 0.21

+/- 0.087 10/29/2008 ESO-6241 E-06 30.04 +/- 4.06

-0.099 +/- 0.071 12.96 +/- 12.96 0.24 +/- 0.032 0.11 +/- 0.021 0.35 +/- 0.079 0.31 +/- 0.046 0.62 +/- 0.22 0.37 +/- 0.070 10/29/2008 ESO-6244 E-20 34.98 +/- 2.22 10/29/2008 ESO-6242 E-08 25.85 +/- 3.49

-0.069 +/- 0.065 13.23 +/- 0.61 0.17 +/- 0.022 0.085 +/- 0.019 0.30 +/- 0.071 0.22 +/- 0.048 0.46 +/- 0.17 0.31 +/- 0.061 2.0 0.15 10/29/2008 ESO-6243 Annual Location E-09 Mean s.d.

Gross Beta Be-7 K-40 Cs-1 37 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 39.16 +/- 4.17 30.03 +/- 8.19 0.113 18.98 0.15 0.14 0.47 0.32 0.71 0.55

+/- 0.083

+/- 0.85

+/- 0.026

+/- 0.028

+/- 0.092

+/- 0.063

+/- 0.28

+/- 0.156

-0.006 14.76 0.22 0.17 0.57 0.40 0.98 0.46

+/- 0.074

+/- 0.69

+/- 0.030

+/- 0.029

+/- 0.089

+/- 0.050

+/- 0.25

+/- 0.095 0.061 14.89 0.16 0.14 0.43 0.29 0.80 0.47

+/- 0.16

+/- 3.65

+/- 0.09

+/- 0.05

+/- 0.20

+/- 0.11

+/- 0.32

+/- 0.18 2.0 0.15 31

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN VEGETATION SAMPLES (Tri-Annual Collections)

Sample Description and Concentration (pCilg wet)

Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Co-60 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Co-60 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Co-60 E-01 5/28/2008 EG-2540 5.28 6.51 + 0.15 0.12 + 0.06 5.16 +/- 0.40 0.000 +/-.0.007 0.000 + 0.006 0.002 +/- 0.008

-0.005 + 0.007 E-04 5/28/2008 EG-2543 4.04 4.23 +/- 0.09 E-02 5/28/2008 EG-2541 4.20 7.55 +/- 0.17 0.31 +/- 0.13 5.86 +/- 0.44 0.001 +/- 0.006 0.002 + 0.006 0.004 +/- 0.008 0.001 +/- 0.009 E-06 5/28/2008 EG-2544 3.54 8.48 +/- 0.19 E-03 5/28/2008 EG-2542 3.81 9.68 +/- 0.23 0.62 +/- 0.23 7.27 + 0.51 0.002 _ 0.010

-0.011 + 0.011 0.000 +/- 0.011 0.010 +/- 0.010 E-08 5/28/2008 EG-2545 3.40 4.28 +/- 0.08 0.78 +/- 0.24 6.35 +/- 0.56 0.005 +/- 0.012

-0.006 +/- 0.014 0.014 +/- 0.013 0.004 +/- 0.012 Req. LLD 0.25 0.060 0.060 0.080 0.060 Req. LLD 0.26 5.89

-0.003

-0.006 0.003 0.005

+/- 0.12

+/- 0.44

+/- 0.007

+/- 0.007

+/- 0.009

. 0.008 0.30 5.02

-0.004 0.004 0.011 0.010

+/- 0.12

+/- 0.51

+ 0.012

. 0.010

+/- 0.015

+ 0.012 0.25 0.060 0.060 0.080 0.060 E-09 5/28/2008 EG-2546 4.20 4.63 +/- 0.09 0.32 - 0.16 6.90 - 0.55 0.000 4- 0.008 0.002 +/- 0.007 0.000 +/- 0.009

-0.003 + 0.010 E-20 5/28/2008 EG-2547 3.22 4.37 +/- 0.09 0.23 +/- 0.17 6.34 +/- 0.77

-0.007 +/- 0.017

-0.009 +/- 0.015

-0.006 +/- 0.018

-0.007 +/- 0.018 Req. LLD 0.25 0.060 0.060 0.080 0.060 32

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN VEGETATION SAMPLES (Tri-Annual Collections)

Sample Description and Concentration (pCi/g wet)

Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Co-60 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Co-60 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Co-60 E-0 1 7/30/2008 EG-3929 3.46 7.95 +/- 0.20 0.76 6.29 0.014

-0.006 0.004 0.002

+ 0.26

+ 0.58

+ 0.011

+ 0.012

+ 0.011

+ 0.017 E-02 7/30/2008 EG-3930 3.05 8.01 +/- 0.20 1.91 +/- 0.30 6.97 +/- 0.74

-0.005 +/- 0.013

-0.003 +/- 0.015 0.009 +/- 0.018

-0.003 +/- 0.021 E-06 7/30/2008 EG-3933 2.39 6.50 +/- 0.24 E-03 7/30/2008 EG-3931 4.82 9.60 +/- 0.33 Req. LLD 0.25 0.29 6.62 0.026 0.010

-0.019

-0.013

  • +

+

+

+

+

+

0.15 0.70 0.014 0.015 0.016 0.020 0.060 0.060 0.080 0.060 E-04 7/30/2008 EG-3932 2.38 5.73 +/- 0.23 1.70 +/- 0.32 4.37 +/- 0.56

-0.002 + 0.013 0.002 +/- 0.015 0.017 + 0.013 0.003 + 0.018 E-09 7/30/2008 EG-3936 2.78 8.60 +/- 0.34 1.84 +/- 0.38 4.98 +/- 0.57 0.001 +/- 0.012 0.014 + 0.012 0.005 +/- 0.014 0.018 + 0.016 E-08 7/30/2008 EG-3934 2.17 9.70 +/- 0.38 1.67 +/- 0.32 6.02 + 0.58 0.001 + 0.013 0.013 + 0.011 0.015 + 0.014

-0.001 + 0.016 Req. LLD 0.25 1.44 4.64 0.005 0.001 0.019

-0.003

+ 0.29

+ 0.55

+ 0.012

+ 0.010

+ 0.013

+ 0.014 0.060 0.060 0.080 0.060 E-20 7/30/2008 EG-3937 2.78 8.73 +/- 0.25 0.99 +/- 0.30 5.83 +/- 0.60 0.016 +/- 0.011 0.004 +/- 0.011 0.006 +/- 0.014

-0.003 +/- 0.016 Req. LLD 0.25 0.060 0.060 0.080 0.060 33

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN VEGETATION SAMPLES (Tri-Annual Collections)

Sample Description and Concentration (pCilg wet)

Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-1 34 Cs-137 Co-60 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Co-60 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Co-60 E-01 10/29/2008 EG-6229 2.78 11.27 +/- 0.34 3.41 +/- 0.31 4.91 +/- 0.47 0.014 +/- 0.012

-0.003 + 0.008 0.007 + 0.010

-0.010 +/- 0.010 E-04 10/29/2008 EG-6232 3.57 9.89 +/- 0.30 3.22 +/- 0.29 5.92 +/- 0.46

-0.006 +/- 0.007 0.001 +/- 0.005 0.006 +/- 0.009 0.005 +/- 0.008 E-09 10/29/2008 EG-6235 2.08 8.57 +/- 0.37 3.73 + 0.20 4.34 +/- 0.30 0.016 + 0.007

-0.005 +/- 0.007 0.004 + 0.008 0.003. 0.008 E-02 10/29/2008 EG-6230 2.67 6.07 +/- 0.22 1.64 +/- 0.29 5.81 +/- 0.49

-0.022 +/- 0.011

-0.004 +/- 0.010

-0.006 +/- 0.011

-0.002 +/- 0.009 E-06 10/29/2008 EG-6233 2.13 5.77 +/- 0.18 2.36 +/- 0.09 2.43 +/- 0.13

-0.002 +/- 0.003 0.000 +/- 0.003 0.010 +/- 0.003 0.001 +/- 0.003 E-20 10/29/2008 EG-6236 3.08 9.57 +/- 0.27 E-03 10/29/2008 EG-6231 5.22 9.10 +/- 0.22 Req. LLD 0.25 2.97 6.26 0.013

-0.004

-0.001

-0.001

+ 0.24

+ 0.41

+/- 0.009

+ 0.007

+ 0.008

+ 0.007 0.060 0.060 0.080 0.060 Req. LLD E-08 10/29/2008 EG-6234 1.68 7.76 +/- 0.30 5.08 +/- 0.16 4.74 +/- 0.20 0.003 +/- 0.004

-0.001 +/- 0.004 0.004 +/- 0.004 0.003 +/- 0.004 0.25 0.060 0.060 0.080 0.060 Req. LLD 0.25 3.12 5.18 0.019

-0.003 0.005 0.001

+ 0.38

+ 0.53

+ 0.012

+ 0.010

+ 0.011

+ 0.011 0.060 0.060 0.080 0.060 Gross Beta Annual Mean + s.d.

Be-7 Annual Mean + s.d.

K-40 Annual Mean + s.d.

1-131 Annual Mean + s.d.

Cs-134 Annual Mean + s.d.

Cs-137 Annual Mean + s.d.

Co-60 Annual Mean + s.d.

7.61 +/- 2.03 1.63 +/- 1.36 5.59 +/- 1.07 0.004 +/- 0.010 0.000 +/- 0.006 0.005 +/- 0.008 0.001 +/- 0.006 34

POINT BEACH NUCLEAR PLANT Aquatic Vegetation, analyses for gross beta and gamma emitting isotopes.

Collection:

Semiannual Units:

pCi/g wet Sample Description and Concentration Collection Date Lab Code Location Ratio (wet wt./dry wt.)

Gross Beta Be-7 K-40 Co-58 Co-60 Cs-134 Cs-137 Collection Date Lab Code Location Ratio (wet wt./dry wt.)

Gross Beta Be-7 K-40 Co-58 Co-60 Cs-134 Cs-137 Collection Date Lab Code Location Ratio (wet wt./dry wt.)

Gross Beta Be-7 K-40 Co-58 Co-60 Cs-134 Cs-137 06-04-08 ESL-2828 E-05 4.25 5.69 +/- 0.42 1.42 +/- 0.26 3.00 +/- 0.37 0.006 +/- 0.009 0.001 +/- 0.013

-0.007 +/- 0.009 0.016 +/- 0.012 08-07-08 ESL-4172 E05 4.31 7.91 +/- 0.66 2.25 +/- 0.22 2.22 +/- 0.29 0.006 +/- 0.008 0.006 +/- 0.009 0.000 +/- 0.008 0.028 +/- 0.009 10-09-08 ESL-5518 E-05 4.66 6.54 +/- 0.42 0.43 +/- 0.15 1.96 +/- 0.21 0.001 +/- 0.006

-0.003 +/- 0.006 0.000 +/- 0.006 0.009 +/- 0.007 06-04-08 ESL-2829 E-12 3.80 11.04 +/- 0.66 0.79 +/- 1.28 2.67 +/- 2.67 0.015 +/- 0.007 0.019 +/- 0.007

-0.002 +/- 0.007 0.038 +/- 0.017 08-07-08 ESL-4173 E-12 2.47 10.55 +/- 1.23 2.61 +/- 0.21 2.67 +/- 0.32 0.006 +/- 0.008 0.007 +/- 0.009 0.004 +/- 0.008 0.031 +/- 0.011 10-09-08 ESL-5519 E-12 2.07 10.34 +/- 1.04 1.42 +/- 0.26 3.86 +/- 0.30 0.001 +/- 0.008 0.008 +/- 0.009

-0.007 +/- 0.008 0.027 +/- 0.012 Required LLD 0.25 0.25 0.25 0.25 0.25 Required LLD 0.25 0.25 0.25 0.25 0.25 Required LLD Annual Mean s.d.

0.25 0.25 0.25 0.25 0.25 8.68 +/- 2.28 1.49 +/- 0.83 2.73 +/- 0.66 0.006 +/- 0.005 0.006 +/- 0.008

-0.002 +/- 0.004 0.025 +/- 0.011 35

POINT BEACH NUCLEAR PLANT AMBIENT GAMMA RADIATION (TLD) 1st. Quarter, 2008 Date Annealed:

12-05-07 Days in the field 85 Date Placed:

01-10-08 Days from Annealing Date Removed:

04-04-08 to Readout:

125 Date Read:

04-08-08 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-12 E-1 4 E-15 E-1 6 E-17 E-1 8 E-22 E-23 E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 Control E-20 Mean+/-s.d.

85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 15.3 +/- 1.1 19.9 +/- 1.1 20.5 +/- 1.3 17.8 +/- 1.3 16.8 +/- 0.9 17.9 +/- 0.9 18.0 +/- 1.0 17.1 +/- 0.7.

19.9 +/- 0.7 15.8 +/- 0.3 18.9 +/- 0.4 18.3 +/- 0.6 17.4 +/- 0.3 18.9 +/- 0.7 18.5 +/- 0.7 18.9 +/- 1.1 18.1 +/- 0.5 18.8 +/- 0.6 17.2 +/- 0.2 17.2 +/- 0.5 19.5 +/- 0.4 15.1 +/- 0.3 15.7 +/- 0.9 17.1 +/- 0.7 17.9 +/- 0.6 17.0 +/- 0.6 17.5 +/- 1.4 15.0 +/- 0.6 19.4 +/- 0.9 17.8 +/- 1.5 10.9 +/- 1.3 15.5 +/- 1.3 16.1 +/- 1.5 13.4 +/- 1.5 12.4 +/- 1.2 13.5 +/- 1.2 13.6 +/- 1.2 12.7 + 1.0 15.5 +/- 1.0 11.4 +/- 0.8 14.5 +/- 0.8 13.9 +/- 1.0 13.0 +/- 0.8 14.5 +/- 1.0 14.1 +/- 1.0 14.5 +/- 1.3 13.7 +/- 0.9 14.4 +/- 1.0 12.8 + 0.8 12.8 +/- 0.9 15.1 +/-0.8 10.7 + 0.8 11.3 _ 1.2 12.7 + 1.0 13.5 +/- 1.0 12.6 + 1.0 13.1 +/-1.6 10.6 + 1.0 0.90 +/- 0.11 1.28 +/- 0.11 1.33 +/- 0.12 1.10 +/- 0.12 1.02 +/- 0.10 1.11 +/- 0.10 1.12 +/- 0.10 1.05 +/- 0.08 1.28 +/- 0.08 0.94 +/- 0.07 1.19 +/- 0.07 1.14 +/- 0.08 1.07 +/- 0.07 1.19 +/- 0.08 1.16 +/- 0.08 1.19 +/- 0.11 1.13 +/- 0.07 1.19 +/- 0.08 1.05 +/- 0.06 1.05 +/- 0.07 1.24 +/- 0.07 0.88 +/- 0.07 0.93 +/- 0.10 1.05 +/- 0.08 1.11 +/- 0.08 1.04 +/- 0.08 1.08 +/- 0.13 0.87 +/- 0.08 1.24 +/- 0.10 1.10 +/- 0.11 85 15.0 +/- 1.2 13.4 + 1.5 Date Annealed Date Read ITC-1 ITC-2 In-Transit Exposure 12-05-07 03-26-08 01-22-08 04-08-08 Total mR 7.2 +/- 0.7 2.2 +/- 0.2 6.1 +/- 0.1 2.1 +/- 0.1 36

POINT BEACH NUCLEAR PLANT AMBIENT GAMMA RADIATION (TLD) 2nd Quarter, 2008 Date Annealed:

03-26-08 Days in the field 89 Date Placed:

04-04-08 Days from Annealing Date Removed:

07-02-08 to Readout:

105 Date Read:

07-09-08 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-1 2 E-14 E-1 5 E-1 6 E-17 E-18 E-22 E-23 E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 12.7 +/- 1.1 17.9 +/- 1.0 18.4 +/- 1.4 14.5 +/- 0.3 16.2 +/- 0.4 14.2 +/- 0.5 13.5 +/- 0.5 14.2 +/- 0.5 16.4 +/- 0.9 11.7 +/-0.8 15.2 +/- 0.9 18.3 +/- 0.9 14.5 +/- 0.2 15.2 +/- 0.8 16.4 +/- 0.3 16.1 +/- 0.3 17.2 +/- 0.7 15.2 +/- 0.2 16.7 +/- 0.3 13.3 +/- 0.2 17.9 +/- 0.4 11.3 +/- 0.3 12.0 +/- 0.4 15.0 +/- 0.4 16.7 +/- 1.3 14.8 +/- 0.2 14.6 +/- 0.7 13.8 +/- 0.4 9.8 +/- 1.2 15.0 +/- 1.1 15.5 +/- 1.5 11.6 +/- 0.5 13.3 +/- 0.6 11.3 +/- 0.6 10.6 +/- 0.6 11.3 +/- 0.6 13.5 +/- 1.0 8.8 +/- 0.9 12.3 +/- 1.0 15.4 +/- 1.0 11.6 +/- 0.4 12.3 +/- 0.9 13.5 +/- 0.5 13.2 +/- 0.5 14.3 +/- 0.8 12.3 +/- 0.4 13.8 +/- 0.5 10.4 +/- 0.4 15.0 +/- 0.6 8.4 +/- 0.5 9.1 +/- 0.6 12.1 +/- 0.6 13.8 +/- 1.4 11.9 +/- 0.4 11.7 +/- 0.8 10.9 +/- 0.6 0.77 +/- 0.09 1.18 + 0.08 1.22 +/- 0.11 0.91 +/- 0.04 1.04 + 0.04 0.88 +/- 0.05 0.83 +/- 0.05 0.88 +/- 0.05 1.06 +/- 0.08 0.69 +/- 0.07 0.96 +/- 0.08 1.21 +/- 0.08 0.91 +/- 0.03 0.96 +/- 0.07 1.06 +/- 0.04 1.03 +/- 0.04 1.12 +/- 0.06 0.96 +/- 0.03 1.08 +/- 0.04 0.81 +/- 0.03 1.18 +/- 0.04 0.66 +/-.0.04 0.71 +/- 0.04 0.95 +/- 0.04 1.08 +/- 0.11 0.93 +/- 0.03 0.92 +/- 0.06 0.85 +/- 0.04 0.90 +/- 0.03 0.96 + 0.15 Control E-20 89 14.4 +/- 0.2 11.5 +/- 0.4 Mean+/-s.d.

15.1 +/- 1.9 12.2 +/- 1.9 Date Annealed Date Read ITC-1 ITC-2 In-Transit Exposure 03-26-08 06-13-08 04-08-08 07-09-08 Total mR 2.2 +/- 0.2 3.8 +/- 0.3 2.1 +/- 0.1 3.7 +/- 0.1 37

POINT BEACH NUCLEAR PLANT AMBIENT GAMMA RADIATION (TLD) 3rd Quarter, 2008 Date Annealed:

06-13-08 Days in the field 91 Date Placed:

07-02-08 Days from Annealing Date Removed:

10-01-08 to Readout:

117 Date Read:

10-08-08 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-1 2 E-14 E-15 E-1 6 E-1 7 E-18 E-22 E-23 E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 Control E-20 Mean+/-s.d.

15.0 20.2 23.1 19.2 18.2 17.6 17.9 18.4 21.6 14.2 19.4 20.6 19.0 19.4 21.4 20.5 20.2 19.1 18.8 17.1 20.9 14.0 15.1 17.8 19.5 19.5 19.0 16.9

+ 1.1

+0.3

+ 1.3

+1.1

+1.0

+0.8

+0.8

+ 1.4

+0.6

+0.5

+/- 0.6

+/-+0.5

+/-0.3

+/- 0.8

+0.9

+1.1

+/- 0.4

_+0.7

+/-+0.4

+0.5

+/- 0.3

+/- 0.3

+0.6

+/-0.7

+/- 1.0

+0.6

+/- 1.2

+0.6 11.4 16.6 19.5 15.6 14.6 14.0 14.3 14.8 18.0 10.6 15.8 17.0 15.4 15.8 17.8 16.9 16.6 15.5 15.2 13.5 17.3 10.4 11.5 14.2 15.9 15.9 15.4 13.3

+ 1.2

+ 0.5

+ 1.4

+ 1.2

+1.1

+/-+0.9

+0.9

+ 1.5

+0.7

+0.7

+0.7

+0.7

+0.5

+0.9

+ 1.0

+ 1.2

+/-+0.6

+0.8

+/-+0.6

+0.7

+0.5

+0.5

+ 0.7

+/- 0.8

+1.1

+0.7

+1.3

+0.7 0.88 1.28 1.50 1.20 1.12 1.08 1.10 1.14 1.38 0.82 1.22 1.31 1.18 1.22 1.37 1.30 1.28 1.19 1.17 1.04 1.33 0.80 0.88 1.09 1.22 1.22 1.18 1.02

+/- 0.09

+/- 0.04

+/- 0.11

+/- 0.09

+/- 0.08

+/- 0.07

+/- 0.07

+/- 0.11

+/- 0.06

+/- 0.05

+/- 0.06

+/- 0.05

+/- 0.04

+/- 0.07

+/- 0.08

+/- 0.09

+/- 0.05

+/- 0.06

+/- 0.05

+/- 0.05

+/- 0.04

+/- 0.04

+/- 0.06

+/- 0.06

+/- 0.08

+/- 0.06

+/-+0.10

_ 0.06 91 18.8 +/- 1.1 18.7 +/- 2.2 15.2 +/- 1.2 15.1 +/- 2.2 1.17 +/- 0.09 1.16 +/- 0.16 Date Annealed Date Read ITC-1 ITC-2 In-Transit Exposure 06-13-08 09-15-08 07-09-08 10-08-08 Total mR 3.8 +/- 0.3 3.8 +/- 0.3 3.7 +/- 0.1 3.1 +/- 0.1 38

POINT BEACH NUCLEAR PLANT AMBIENT GAMMA RADIATION (TLD) 1st. Quarter, 2008 Date Annealed:

12-05-07 Days in the field 85 Date Placed:

01-10-08 Days from Annealing Date Removed:

04-04-08 to Readout:

125 Date Read:

04-08-08 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-1 2 E-14 E-1 5 E-16 E-1 7 E-1 8 E-22 E-23 E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 Control E-20 Mean+/-s.d.

85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 15.3 +/- 1.1 19.9 +/- 1.1 20.5 +/- 1.3 17.8 +/- 1.3 16.8 +/- 0.9 17.9 +/- 0.9 18.0 +/- 1.0 17.1 +/- 0.7 19.9 +/- 0.7 15.8 +/- 0.3 18.9 +/- 0.4 18.3 +/- 0.6 17.4 +/- 0.3 18.9 +/- 0.7 18.5 +/- 0.7 18.9 +/- 1.1 18.1 +/- 0.5 18.8 +/- 0.6 17.2 +/- 0.2 17.2 +/- 0.5 19.5 +/- 0.4 15.1 +/- 0.3 15.7 +/- 0.9 17.1 +/- 0.7 17.9 +/- 0.6 17.0 +/- 0.6 17.5 +/- 1.4 15.0 +/- 0.6 19.4 +/- 0.9 17.8 +/- 1.5 10.9 +/- 1.3 15.5 +/- 1.3 16.1 +/- 1.5 13.4 +/- 1.5 12.4 +/- 1.2 13.5 +/- 1.2 13.6 +/- 1.2 12.7 +/- 1.0 15.5 +/- 1.0 11.4 +/- 0.8 14.5 +/- 0.8 13.9 +/- 1.0 13.0 +/- 0.8 14.5 +/- 1.0 14.1 +/- 1.0 14.5 +/- 1.3 13.7 +/- 0.9 14.4 +/- 1.0 12.8 +/- 0.8 12.8 +/- 0.9 15.1 +/- 0.8 10.7 +/- 0.8 11.3 +/- 1.2 12.7 +/- 1.0 13.5 +/- 1.0 12.6 +/- 1.0 13.1 +/- 1.6 10.6 +/- 1.0 15.0 +/- 1.2 13.4 +/- 1.5 0.90 +/- 0.11 1.28 +/- 0.11 1.33 +/- 0.12 1.10 +/- 0.12 1.02 +/- 0.10 1.11 +/- 0.10 1.12 +/- 0.10 1.'05 +/- 0.08 1.28 +/- 0.08 0.94 +/- 0.07 1.19 +/- 0.07 1.14 +/- 0.08 1.07 +/- 0.07 1.19 +/- 0.08 1.16 +/- 0.08 1.19 +/- 0.11 1.13 +/- 0.07 1.19 +/- 0.08 1.05 +/- 0.06 1.05 +/- 0.07 1.24 +/- 0.07 0.88 +/- 0.07 0.93 +/- 0.10 1.05 +/- 0.08 1.11 +/- 0.08 1.04 +/- 0.08 1.08 +/- 0.13 0.87 +/- 0.08 1.24 +/- 0.10 1.10 +/- 0.11 Date Annealed Date Read ITC-1 ITC-2 In-Transit Exposure 12-05-07 03-26-08 01-22-08 04-08-08 Total mR,

7.2 +/- 0.7 2.2 +/- 0.2 6.1 +/- 0.1 2.1 +/- 0.1 36

POINT BEACH NUCLEAR PLANT AMBIENT GAMMA RADIATION (TLD) 2nd Quarter, 2008 Date Annealed:

03-26-08 Days in the field 89 Date Placed:

04-04-08 Days from Annealing Date Removed:

07-02-08 to Readout:

105 Date Read:

07-09-08 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-12 E-1 4 E-15 E-16 E-1 7 E-18 E-22 E-23 E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 12.7 17.9 18.4 14.5 16.2 14.2 13.5 14.2 16.4 11.7 15.2 18.3 14.5 15.2 16.4 16.1 17.2 15.2 16.7 13.3 17.9 11.3 12.0 15.0 16.7 14.8 14.6 13.8

+ 1.1

+ 1.0

+ 1.4

+0.3

+ 0.4

+0.5

+0.5

+0.5

+/-0.9

+/-0.8

+0.9

+0.9

+ 0.2

+0.8

+0.3

+0.3

+0.7

+0.2

_+0.3

+0.2

+/- 0.4

+/- 0.3

+0.4

+/- 0.4

+1.3

-+0.2

_+0.7

+0.4 9.8 15.0 15.5 11.6 13.3 11.3 10.6 11.3 13.5 8.8 12.3 15.4 11.6 12.3 13.5 13.2 14.3 12.3 13.8 10.4 15.0 8.4 9.1 12.1 13.8 11.9 11.7 10.9

  • 1.2

+/-+1.1

- 1.5

_+0.5

_+0.6

_ 0.6

+0.6

+0.6

+1.0

+0.9

_ 1.0

_+1.0

  • 0.4

_+0.9

+/- 0.5

_+0.5

+0.8

+/- 0.4

+/-+0.5

_+0.4

+/- 0.6

+/- 0.5

+/- 0.6

+/- 0.6

+/- 1.4

+/- 0.4

+/- 0.8

+/- 0.6 0.77 1.18 1.22 0.91 1.04 0.88 0.83 0.88 1.06 0.69 0.96 1.21 0.91 0.96 1.06 1.03 1.12 0.96 1.08 0.81 1.18 0.66 0.71 0.95 1.08 0.93 0.92 0.85

+/- 0.09

+/- 0.08

+/- 0.11

+/- 0.04

+/- 0.04

+/- 0.05

+/- 0.05

+/- 0.05

+/- 0.08

+/- 0.07

+/- 0.08

+/- 0.08

+/- 0.03

+/- 0.07

+/- 0.04

+/- 0.04

+/- 0.06

+/- 0.03

+/- 0.04

+/- 0.03

+/- 0.04

+/- 0.04

+/- 0.04

+/- 0.04

+/- 0.11

+/- 0.03

+/- 0.06

+/- 0.04 Control E-20 89 14.4 +/- 0.2 11.5 +/- 0.4 0.90 +/- 0.03 0.96 +/- 0.15 Mean+/-s.d.

15.1 +/- 1.9 12.2 +/- 1.9 Date Annealed Date Read ITC-1 ITC-2 In-Transit Exposure 03-26-08 06-13-08 04-08-08 07-09-08 Total mR 2.2 +/- 0.2 3.8 +/- 0.3 2.1 +/- 0.1 3.7 +/- 0.1 37

POINT BEACH NUCLEAR PLANT AMBIENT GAMMA RADIATION (TLD) 3rd Quarter, 2008 Date Annealed:

06-13-08 Days in the field 91 Date Placed:

07-02-08 Days from Annealing Date Removed:

10-01-08 to Readout:

117 Date Read:

10-08-08 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-12 E-14 E-1 5 E-1 6 E-1 7 E-1 8 E-22 E-23 E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 Control E-20 Mean+/-s.d.

91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 15.0 +/- 1.1 20.2 +/- 0.3 23.1 +/- 1.3 19.2 + 1.1 18.2 1.0 17.6 + 0.8 17.9 +/- 0.8 18.4 +/- 1.4 21.6 + 0.6 14.2 +/- 0.5 19.4 + 0.6 20.6 + 0.5 19.0 +/-0.3 19.4 +/- 0.8 21.4 + 0.9 20.5 + 1.1 20.2 +/- 0.4 19.1 +/- 0.7 18.8 +/- 0.4 17.1 +/- 0.5 20.9 +/- 0.3 14.0 +/- 0.3 15.1 +/- 0.6 17.8 +/- 0.7 19.5 +/- 1.0 19.5 +/- 0.6 19.0 +/- 1.2 16.9 +/- 0.6 18.8 + 1.1 18.7 + 2.2 11.4 +/- 1.2 16.6 +/- 0.5 19.5 +/- 1.4 15.6 +/- 1.2 14.6 +/- 1.1 14.0 +/- 0.9 14.3 +/- 0.9 14.8 +/- 1.5 18.0 +/- 0.7 10.6 +/-0.7 15.8 +/-0.7 17.0 +/- 0.7 15.4 +/- 0.5 15.8 +/- 0.9 17.8 +/- 1.0 16.9 +/- 1.2 16.6 +/- 0.6 15.5 +/- 0.8 15.2 +/- 0.6 13.5 + 0.7 17.3 +/- 0.5 10.4 0 0.5 11.5 +/-0.7 14.2 +0.8 15.9 +/- 1.1 15.9 +/- 0.7 15.4 +/- 1.3 13.3 +/- 0.7 15.2 +/- 1.2 15.1 +/- 2.2 0.88 +/- 0.09 1.28 +/- 0.04 1.50 +/- 0.11 1.20 +/- 0.09 1.12 +/- 0.08 1.08 +/- 0.07 1.10 +/- 0.07 1.14 +/-0.11 1.38 +/- 0.06 0.82 +/- 0.05 1.22 +/- 0.06 1.31 +/- 0.05 1.18 +/- 0.04 1.22 + 0.07 1.37 +/- 0.08 1.30 +/- 0.09 1.28 +/- 0.05 1.19 +/- 0.06 1.17 +/- 0.05.

1.04 +/- 0.05 1.33 +/- 0.04 0.80 +/- 0.04 0.88 +/- 0.06 1.09 +/- 0.06 1.22 +/- 0.08 1.22 +/- 0.06 1.18 +/- 0.10 1.02 +/- 0.06 1.17 +/- 0.09 1.16 +/- 0.16 Date Annealed Date Read ITC-1 ITC-2 In-Transit Exposure 06-13-08 09-15-08 07-09-08 10-08-08 Total mR 3.8 +/- 0.3 3.8 +/- 0.3 3.7 +/- 0.1 3.1 +/- 0.1 38

POINT BEACH NUCLEAR PLANT AMBIENT GAMMA RADIATION (TLD) 4th Quarter, 2008 Date Annealed:

09-15-08 Days in the field 100 Date Placed:

10-01-08 Days from Annealing Date Removed:

01-09-09 to Readout:

121 Date Read:

01-14-09 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 100 16.2 +/- 0.7 10.5 +/- 0.9 0.73 +/- 0.06 E-2 100 22.6 +/- 1.3 16.9 +/- 1.4 1.18 +/- 0.10 E-3 100 24.1 +/- 1.7 18.4 +/- 1.8 1.29 +/- 0.13 E-4 100 19.1 +/- 0.4 13.4 +/- 0.7 0.94 +/- 0.05 E-5 100 20.9 +/- 0.4 15.2 +/- 0.7 1.06 +/- 0.05 E-6 100 18.9 +/- 0.5 13.2 +/- 0.8 0.92 +/- 0.05 E-7 100 17.8 +/- 0.5 12.1 +/- 0.8 0.85 +/- 0.05 E-8 100 18.8 +/- 0.7 13.1 +/- 0.9 0.92 +/- 0.06 E-9 100 21.7 +/- 1.1 16.0 +/- 1.2 1.12 +/- 0.09 E-12 100 15.7 +/- 1.2 10.0 +/- 1.3 0.70 +/- 0.09 E-14.

100 18.9 +/- 0.5 13.2 +/- 0.8 0.92 +/- 0.05 E-15 100 23.0 +/- 1.0 17.3 +/- 1.2 1.21 +/- 0.08 E-16 100 19.2 +/- 0.2 13.5 +/- 0.6 0.94 +/- 0.04 E-17 100 19.5 +/- 1.0 13.8 +/- 1.2 0.96 +/- 0.08 E-18 100 20.5 +/- 0.4 14.8 +/- 0.7 1.03 +/- 0.05 E-22 100 20.9 +/- 0.4 15.2 +/- 0.7 1.06 +/- 0.05 E-23 100 21.5 +/- 0.9 15.8 +/- 1.1 1.10 +/- 0.08 E-24 100 19.4 +/- 0.3 13.7 +/- 0.7 0.96 +/- 0.05 E-25 100 21.3 +/- 0.4 15.6 +/- 0.7 1.09 +/- 0.05 E-26 100 18.2 +/- 0.6 12.5 +/- 0.8 0.87 +/- 0.06 E-27 100 22.4 +/- 0.5 16.7 +/- 0.8 1.17 +/- 0.05 E-28 100 15.1 +/- 0.4 9.4 +/- 0.7 0.66 +/- 0.05 E-29 100 16.1 +/- 0.7 10.4 +/- 0.9 0.73 +/- 0.06 E-30 100 18.9 +/- 0.4 13.2 +/- 0.7 0.92 +/- 0.05 E-31 100 21.2 +/- 1.5 15.5 +/- 1.6 1.08 +/- 0.11 E-32 100 18.9 +/- 0.2 13.2 +/- 0.6 0.92 +/- 0.04 E-38 100 18.8 +/- 0.3 13.1 +/- 0.7 0.92 +/- 0.05 E-39 100 17.9 +/- 0.4 12.2 +/- 0.7 0.85 +/- 0.05 Control E-20 100 17.4 +/- 0.8 11.7 +/- 1.0 0.82 +/- 0.07 Mean+/-s.d.

19.5 +/- 2.3 13.8 +/- 2.3 0.96 +/- 0.15 In-Transit Exposure Date Annealed 09-15-08 12-02-08 Date Read 10-08-08 01-15-09 Total mR ITC-1 3.8 +/- 0.3 8.2 +/- 0.4 ITC-2 3.1 +/- 0.1 7.8 +/- 0.3 Annual Indicator Mean+/-s.d.

17.8 +/- 2.6 13.6 +/- 2.2 1.05 0.17 Annual Control Mean+/-s.d.

17.5 +/- 2.2 13.3 +/- 2.0 1.03 0.20 Annual Indicator/Control Mean+/-s, 17.8 +/- 2.6 13.6 +/- 2.2 1.05 0.17 39

POINT BEACH NUCLEAR PLANT Groundwater Tritium Monitoring Program (Monthly Collections)

Units = pCi/L Intermittent Streams Sample ID GW-01 GW-02 Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCiL)

Date Lab Code (pCi/L)

(pCi/L) 03-27-08 EWW-1264 57 +/- 92

<171 03-27-08 EWW-1 265 276 +/- 101

<171 04-23-08 EWW-1957 91 +/- 97

<178 04-23-08 EWW-1958 342 +/- 107

<178 05-30-08 EWW-2618 22 +/- 73

<145 05-30-08 EWW-2619 69 +/- 76

<145 06-25-08 EWW-3136 58 +/- 88

<172 06-25-08 EWW-3137 165 +/- 92

<172 07-31-08 EWW-4126

-1 +/- 74

<150 07-31-08 EWW-4127 27 +/- 76

,<150 10-30-08 EWW-6223 66 +/- 80

<153 09-03-08 EWW-4889 70 +/- 76

<147 11-26-08 EWW-6733 71 +/- 77

<147 10-30-08 EWW-6224 141 +/- 83

<153 11-26-08 EWW-6734 21 +/- 74

<147 Mean + s.d.

52 +/- 31 Mean + s.d.

139 +/- 118 Sample ID GW-03 GW-17 Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCVL)

Date Lab Code (pCi/L)

(pCi/L) 03-27-08 EWW-1266 135 +/- 96

<171 03-28-08 EWW-1269 252 +/- 100

<171 04-23-08 EWW-1959 71 +/- 96

<178 04-23-08 EWW-1 961 123 +/- 99

<178 05-30-08 EWW-2621 168 +/- 80

<145 10-30-08 EWW-6228 180 +/- 85

<153 06-25-08 EWW-3138 56 +/- 88

<172 11-26-08 EWW-6736

-62 +/- 70

<147 07-31-08 EWW-4128 40 +/- 76

<150 09-03-08 EWW-4890 70 +/- 76

<147 09-24-08 EWW-5142 64 +/- 101

<161 10-30-08 EWW-6226 60 +/- 79

<153 Mean + s.d.

83 +/- 44 Mean + s.d.

123 +/- 134 Wells Sample ID GW-04 (EIC Well)

GW-1 1 Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCi/L)

Date Lab Code (pCi/L)

(pCi/L) 01-31-08 EWW-458 35 +/- 93

<174 01-28-08 EWW-459 85 +/- 95

<174 02-28-08 EWW-783

-17 +/- 74

<152 02-29-08 EWW-825 24 +/- 89

<178 03-27-08 EWW-1 268

-25 +/- 89

<171 03-26-08 EWW-1273 138 +/- 93

<180 04-23-08 EWW-1960

-83 +/- 90

<178 04-30-08 EWW-2097 45 +/- 80

<156 05-30-08 EWW-2622

-12 +/- 71

<145 05-29-08 EWW-2639 108 +/- 77

<145 06-25-08 EWW-3139 30 +/- 86

<172 06-24-08 EWW-3140 124 +/- 91

<172 07-31-08 EWW-4129

-13 +/- 74

<150 07-29-08 EWW-4120 97 +/- 82

<147 09-03-08 EWW-4891

-30 +/- 71

<147 08-27-08 EWW-4595 86 +/- 80

<152 09-24-08 EWW-5143

-32 +/- 96

<161 09-30-08 EWW-5378 67 +/- 96

<154 10-30-08 EWW-6227 81 +/- 80

<153 10-22-08 EWW-6031 106 +/- 85

<151 11-26-08 EWW-6735 85 +/- 77

<147 11-19-08 EWW-6602

-1 +/- 72

<145 12-30-08 EWW-7248 121 +/- 106

<168 12-23-08 EWW-7322 46 +/- 72

<133 Mean + s.d.

12 +/- 60 Mean + s.d.

77 +/- 42 40

POINT BEACH NUCLEAR PLANT Groundwater Tritium Monitoring Program (Monthly Collections)

Units = pCi/L Wells (cont.)

Sample ID GW-12 GW-13 Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCi/L)

Date Lab Code (pCi/L)

(pCi/L) 01-28-08 EWW-460

-35 + 90

<174 01-28-08 EWW-461 110 +/- 96

<174 02-29-08 EWW-826

-64 +/- 85

<178 02-29-08 EWW-827 66 +/- 91

<178 03-26-08 EWW-1274 2 +/- 87

<180 03-26-08 EWW-1275 108 +/- 91

<180 04-30-08 EWW-2098

-51 +/- 75

<156 04-30-08 EWW-2099

-8 +/- 77

<156 05-29-08 EWW-2640

-19 +/- 71

<145 05-29-08 EWW-2641 125 +/- 78

<145 06-24-08 EWW-3141 46 +/- 87

<172 06-24-08 EWW-3142 102 +/- 90

<172 07-28-08 EWW-4121 39 +/- 79

<147 07-28-08 EWW-4122 74 +/- 78

<150 08-27-08 EWW-4596

-24 +/- 74

<152 08-27-08 EWW-4597 104 +/- 81

<152 09-30-08 EWW-5379

-16 +/- 93

<154 09-30-08 EWW-5380 16 +/- 94

<154 10-22-08 EWW-6032

-27 +/- 78

<151 10-22-08 EWW-6033 12 +/- 80

<151 11-19-08 EWW-6603

-14 +/- 71

<145 11-19-08 EWW-6604

-1 +/- 72

<145 12-23-08 EWW-7323 85 +/- 74

<133 12-23-08 EWW-7324 79 +/- 74

<133 Mean + s.d.

-7 +/- 43 Mean + s.d.

66 +/- 48 Sample ID GW-14 GW-15 Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pC VL)

Date Lab Code (pCi/L)

(pCi/L) 01-29-08 EWW-462 96 +/- 96

<174 01-28-08 EWW-463 456 +/- 109

<174 02-29-08 EWW-828 96 +/- 92

<178 02-29-08 EWW-829 404 +/- 105

<178 03-26-08 EWW-1276 124 +/- 92

<180 03-26-08 EWW-1277 450 +/- 105

<180 04-30-08 EWW-2100 86 +/- 82

<156 04-30-08 EWW-2101 466 +/- 98

<156 05-29-08 EWW-2642 189 +/- 81

<145 05-29-08 EWW-2643 450 +/- 93

<145 06-24-08 EWW-3143 138 +/- 91

<172 06-24-08 EWW-3144 533 +/- 107

<172 07-28-08 EWW-4123 59 +/- 77

<150 07-28-08 EWW-4124 433 +/- 94

<150 08-27-08 EWW-4598 96 +/- 81

<152 08-27-08 EWW-4599 507 +/- 100

<152 09-30-08 EWW-5381 82 +/- 97

<154 09-30-08 EWW-5382 434 +/- 111

<154 10-22-08 EWW-6034 52 +/- 82

<151 10-22-08 EWW-6035 542 +/- 104

<151 11-19-08 EWW-6605 15 +/-_73

<145 11-19-08 EWW-6606 344 +/-_88

<145 12-23-08 EWW-7325

-1 +/- 70

<133 12-23-08 EWW-7326 396 +/- 88

<133 Mean + s.d.

86 +/- 52 Mean + s.d.

451 +/- 57 Sample ID GW-16 Collection Tritium LLD Date Lab Code (pCi/L)

(pC/L) 02-29-08 EWW-830 204 +/- 97

<178 03-26-08 EWW-1278 232 +/- 97

<180 04-30-08 EWW-2102 182 +/- 86

<156 05-29-08 EWW-2644 262 +/- 85

<145 06-24-08 EWW-3145 334 +/- 99

<172 07-28-08 EWW-4125 198 +/- 84

<150 08-27-08 EWW-4600 150 +/- 83

<152 09-30-08 EWW-5383 202 +/- 102

<154 10-22-08 EWW-6036 151 +/- 87

<151 11-19-08 EWW-6607 66 +/- 75

<145 12-23-08 EWW-7327 213 +/- 80

<133 Mean + s.d.

199 +/- 68 41

POINT BEACH NUCLEAR PLANT Groundwater Tritium Monitoring Program (Monthly Collections)

Units = pCi/L Beach Drains Sample ID S-1 S-3 Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCi/L)

Date Lab Code (pCi/L)

(pCi/L) 01-11-08 EW-182 355 +/- 97

<155 01'-11-08 EW-183a 1103 +/- 124

<155 02-07-08 EW-514 302 +/- 77

<153 03-07-08 EW-894 317 +/- 108

<158 03-07-08 EW-893 300 +/- 107

<158 04-02-08 EW-1595 401 +/- 97

<151 04-02-08 EW-1 594 391 +/- 96

<151 05-08-08 EW-2291 266 +/- 92

<154 05-08-08 EW-2290 275 +/- 93

<154 06-04-08 EW-2831 425 +/- 103

<172 06-04-08 EW-2830 357 +/- 101

<172 07-10-08 EW-3605 142 +/- 86

<151 07-10-08 EW-3604 352 +/- 95

<151 08-06-08 EW-4145 277 +/- 87

<150 08-06-08 EW-4144 292 +/- 88

<150 09-05-08 EW-4764 356 +/- 89

<147 09-05-08 EW-4763 78 +/- 77

<147 10-09-08 EW-5521.

127 +/- 102

<159 10-09-08 EW-5520 350 +/- 111

<159 11-06-08 EW-6389 254 +/- 85

<147 11-06-08 EW-6388 313 +/- 88/

<147 Mean + s.d.

306 +/- 83 Mean + s.d.

367 +/- 277 Sample ID S-7 S-8 Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCi/L)

Date Lab Code (pCi/L)

(pCi/L) 01-11-08 EW-184 187 +/-90

<155 01-11-08 EW-185 194 +/- 102

<179 04-02-08 EW-1 597 215 +/- 89

<151 Mean + s.d.

205 +/- 15 Sample ID S-9 S-10 Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCVL)

Date Lab Code (pCi/L)

(pCi/L) 01-11-08 EW-186 52 +/- 96

<179 01-11-08 EW-187 320 +/- 107

<179 Tritium recount =1257+/-130 pCi/L; repeat = 1301+/-137 pCi/L. Supplemental analyses in Appendix E.

WV 2,

-e-42

POINT BEACH NUCLEAR PLANT Groundwater Tritium Monitoring Program (Monthly Collections)

Units = pCi/L Sample ID U2 Fagade Subsurface Drain Sump Date Lab Code Tritium (pCi/L) 01-05-08 02-01-08 03-07-08 04-03-08 05-02-08 05-31-08 07-08-08 08-07-08 09-02-08 11-02-08 10-02-08 12-05-08 Mean + s.d.

EW-240 EW-734 EW-1118 EW-1667 EW-2416 EW-2984 EW-3841 EW-5544 EW-5552 EW-7342 EW-5597 EW-7183 462 +/- 112 322 +/- 92 566 +/- 107 482 +/- 112 387 +/- 91 452 +/- 103 424 +/- 96 394 +/- 113 485 +/- 116 393 +/- 89 509 +/- 113 610 +/- 124 457 +/- 81 LLD (pCi/L)

<183

<156

<172

<177

<147

<169

<146

<160

<160

<134

<151

<174 43

POINT BEACH NUCLEAR PLANT Groundwater Tritium Monitoring Program (Quarterly Collections)

Units = pCi/L Quarterly Wells Sample ID GW-05 (WH 6 Well)

GW-06 (SBCC Well)

Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCi/L)

Date Lab Code (pCi/L)

(pCi/L) 01-17-08 EWW-281 96 +/- 100

<183 01-17-08 EWW-282 26 + 97

<183 04-01-08 EWW-1602 63 +/- 82

<151 04-01-08 EWW-1603 107 +/- 84

<151 07-17-08 EWW-3702 62 +/- 77

<140 07-17-08 EWW-3703 30 +/-75

<140 10-15-08 EWW-5679

-36 +/- 83

<139 10-15-08 EWW-5680

-72 +/- 81

<139 Mean + s.d.

46 +/- 57 Mean + s.d.

23 +/- 73 Quarterly Fagade Wells Sample ID GW-09 1Z-361A GW-09 1Z-361B Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCi/L)

Date Lab Code (pCi/L)

(pCiL) 12-13-07 EWW-6390 1331 +/- 128

<154 04-20-08 EWW-6391 210 +/- 87

<154 04-20-08 EWW-6392 1169 +/- 122

<151 04-20-08 EWW-6393 62 +/- 78

<151 07-11-08 EWW-4116 1066 +/- 118

<147 07-11-08 EWW-4117 83 +/-_81

<147 10-26-08 EWW-6253 929 +/- 117

<154 10-26-08 EWW-6254 102 +/- 82

<154 Mean + s.d.

1124 +/- 170 Mean + s.d.

114 +/- 66 Sample ID GW-10 2Z-361A GW-10 2Z-361B Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCVL)

Date Lab Code (pCi/L)

(pCi/L) 04-20-08 EWW-6394 25 +/- 76

<151 04-20-08 EWW-6395 268 +/- 88

<151 07-11-08 EWW-4118 23 +/- 78

<147 07-11-08 EWW-4119 464 +/- 97

<147 10-26-08 EWW-6255 37 +/- 78

<154 10-26-08 EWW-6256 110 +/- 82

<154 Mean + s.d.

28 +/- 8 Mean + s.d.

281 +/- 177 Groundwater Tritium Monitoring Program (Annual Collections)

Units = pCi/L

Bogs, Sample ID GW-07 (North Bog)

GW-08 EIC Bog Collection Tritium LLD Collection Tritium LLD Date Lab Code (pCi/L)

(pCVL)

Date Lab Code (pCi/L)

(pCi/L) 05-30-08 EW-2623 59 +/- 75

<145 05-30-08 EW-2624 67 +/- 75

<145 44

Environmental, Inc.

Midwest Laboratory an Allegheny Technologies Co.

700 Landwehr Road

  • Northbrook, IL 60062-2310 ph. (847) 564-0700 7

fax (847) 564-4517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE:

Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.

January, 2008 through December, 2008

Appendix A Interlaboratory Comparison Program Results Environmental, Inc., Midwest Laboratory has, participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

Results in Table A-1 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.

The results in Table A-2 list results for thermoluminescent dosimeters (TLDs), via International Intercomparison of Environmental Dosimeters, when available, and internal laboratory testing.

Table A-3 lists results of the analyses on in-house "spiked" samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.

Table A-4 lists results of the analyses on in-house "blank" samples for the past twelve months. Data for previous years available upon request.

Table A-5 lists REMP specific analytical results from the in-house "duplicate" program for the past twelve months. Acceptance is based on the difference of the results being less than the sum of the errors.

Complete analytical data for duplicate analyses is available upon request.

The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.

Results in Table A-7 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurement Laboratory Quality Assessment Program (EML).

Attachment A lists the laboratory precision at the 1 sigma level for various analyses. The acceptance criteria in Table A-3 is set at t 2 sigma.

Out-of-limit results are explained directly below the result.

Al

Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSESa One standard deviation Analysis Level for single determination Gamma Emitters 5 to 100 pCi/liter or kg 5.0 pCi/liter

> 100 pCi/liter or kg 5% of known value Strontium-89b 5 to 50 pCi/liter or kg 5.0 pCi/liter

> 50 pCi/liter or kg 10% of known value Strontium-90b 2 to 30 pCi/liter or kg 5.0 pCi/liter

> 30 pCi/liter or kg 10% of known value Potassium-40 2t 0.1 g/liter or kg 5% of known value Gross alpha

-< 20 pCi/liter 5.0 pCi/liter

> 20 pCi/liter 25% of known value Gross beta

-< 100 pCi/liter 5.0 pCilliter

> 100 pCi/liter 5% of known value Tritium

-< 4,000 pCi/liter lo=

169.85 x (known)-0 933

> 4,000 pCi/liter 10% of known value Radium-226,-228

0.1 pCi/liter 15% of known value Plutonium

> 0.1 pCi/liter, gram, or sample 10% of known value Iodine-131,

< 55 pCi/liter 6 pCi/liter Iodine-129b

> 55 pCi/liter 10% of known value Uranium-238,

< 35 pCi/liter 6 pCi/liter Nickel-63b

> 35 pCi/liter 15% of known value TechnetiUM~99b Iron-55 b 50 to 100 pCi/liter

> 100 pCi/liter 10 pCi/liter 10% of known value 20% of known value Other Analyses b a From EPA publication, "Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-60014-81-004.

b Laboratory limit.

A2

TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCi/L)

Lab Code Date Analysis Laboratory ERA Control Resultb Resultc Limits Acceptance STW-1148 STW-1 148 STW-1 149 STW-1 149 STW-1149 STW-1 149 STW-1 149 STW-1 150 STW-1150 STW-1151 STW-1152 STW-1 152 STW-1152 STW-1 153 STW-1154 STW-1 154 STW-1 155 STW-1155 STW-1155 STW-1155 STW-1 155 STW-1 156 STW-1156 STW-1 157 STW-1 157 STW-1157 STW-1164 STW-1 164 STW-1165 STW-165 STW-1 165 STW-1 165 STW-1165 STW-1 166 STW-1166 STW-1 167 STW-1168 STW-1 168 STW-1168 STW-1169 03124/08 03/24/08 03/24/08 03/24/08 03/24108 03/24108 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 07/07/08 07/07/08 07/07/08 07/07/08 07/07/08 07/07/08 07/07/08 07/07/08 07/07/08 07/07108 07/07/08 07/07/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 10/06/08 Sr-89 Sr-90 Ba-1 33 Co-60 Cs-134 Cs-137 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 Ra-228 Uranium H-3 Sr-89 Sr-90 Ba-133 Co-60 Cs-134 Cs-1 37 Zn-65 Gr. Alpha Gr. Beta Ra-226 Ra-228 Uranium Sr-89 Sr-90 Ba-133 Co-60 Cs-134 Cs-137 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 "

Ra-228 Uranium H-3 50.6 +/- 2.4 42.4 +/- 1.4 56.9 +/- 5.4 73.9 +/- 1.6 50.2 +/- 1.9 97.7 +/- 2.2 109.9 +/- 5.8 43.7 +/- 7.5 36.4 +/- 1.8 29.3 +/- 1.4 15.0 +/- 1.1 18.4 +/- 1.8 23.4 +/- 1.3 12551.0 +/- 207.0 24.9 +/- 3.5 39.7 - 0.5 45.0 +/- 1.2 24.9 +/- 3.0 90.4 - 5.3 57.1 +/-2.8 102.9 + 7.3 24.8 +/- 1.6 23.9 +/- 0.9 8.0 + 0.6 7.7 +/-0.8 11.2 +/-0.3 42.2 +/- 3.2 35.4 +/- 1.2 56.9 + 1.0 47.6 +/- 1.3 26.4 +/- 4.0 24.3 +/- 0.7 72.0 +/- 2.9 24.2 +/- 4.8 32.6 +/- 1.0 29.0 +/- 0.3 15.0 +/- 1.0 16.0 +/- 1.0 47.8 +/- 2.0 2357.0 +/- 66,0 60.4 39.2 58.3 76.6 46.6 102.0 106.0 50.8 51.4 28.7 15.3 17.0 24.6 12000.0 28.7 40.0 46.6 25.7 93.2 54.6 98.8 30.7 25.8 8.1 7.4 11.3 48.7 33.6 63.5 49.1 25.6 25.6 68.6 26.9 38.0 28.1 16.1 14.1 50.3 2220.0 48.6 - 68.2 28.8 -45.1 48.3 - 64.3 68.9 - 86.7 37.4 -51.3 91.8 -115.0 95.4 - 126.0 26.5 - 63.7 35.0 - 58.4 23.9 - 33.6 11.4-17.6 11.4 -20.4 19,8 -27.6 10400.0 - 13200.0 20.4 - 35.3 29.4 - 46.0 38.1 -51.8 22.3 -31.0 76.6 - 102.0 49.1 - 62.9 88.9 -118.0 15.7 -40.0 16.1 - 33.7 6.1 -9.5 4.7 -9.5 8.9 - 13,0 38.2 - 56.1 24.6 - 38.8 52.8 - 69.9 44.2 - 56.6 19.7 -28.4 21.6 -31.2 61.2 - 83.0 13.6 - 35.5 25.1 -45.5 23.4 - 33.0 12.0 -18.4 9.4 - 17.1 40.8 - 55.9 1830.0 - 2460.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass.

Pass Pass Pass Pass

-Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing in drinking water conducted by Environmental Resources Associates (ERA).

b Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

Results are presented as the known values, expected laboratory precision (1 sigma. 1 determination) and control limits as provided by ERA.

Al-I

TABLE A-2. Crosscheck program results; Thermoluminescent Dosimetry, (TLD, CaSO 4: Dy Cards).

mR Lab Code Date Known Lab Result Control Description Value

+ 2 sigma Limits Acceptance Environmental, Inc.

2008-1 2008-1 2008-1 2008-1 2008-1 2008-1 2008-1 2008-1 2008-1 2008-1 6/16/2008 6/16/2008 6/1612008 6/16/2008 6/16/2008 6/16/2008 6/16/2008 6/16/2008 6/16/2008 611612008 Environmental, Inc.

2008-2 11/17/2008 2008-2 11/1712008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008

.2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 2008-2 11/17/2008 40 cm.

50 cm.

60 cm.

70 cm.

80 cm, 90 cm.

100 cm.

120 cm.

150 cm.

180 cm.

30 cm.

40 cm.

50 cm.

60 cm.

60 cm.

70 cm.

75 cm.

80 cm.

90 cm.

90 cm.

100 cm.

110 cm.

120 cm.

120 cm.

150 cm.

150 cm.

180 cm.

30.23 19.35 13.44 9.87 7.56 5.97 4.84 3.36 2.15 1.49 63.05 35.46 22.7 15.76 15.76 11.58 10.09 8.87 7.01 7,01 5.67 4.69 3.94 3.94 2.52 2.52 1.75 33.87 +/- 1.17 23.13 +/- 0.57 16.25 +/- 1.10 10.39 +/- 0.52 7.44 +/- 0.51 5.80 +/- 1.04 4.32 +/- 0.43 2.69 +/- 0.15 2.05 +/- 0.69 1.23 +/- 0.80 73.10 +/- 1.84 40.80 +/- 2.30 24.10 +/- 0.58 15.98 +/- 0.55 19.49 +/- 0.93 11,97 +/- 0.54 9.45 +/- 0.28 9.30 +/- 0.18 7.19 +/- 0,43 6.84 +/- 0.42 5.47 +/-+0.19 3.98 +/- 0.27 3.09 +/- 0.21 3.12 +/- 0.34 2.55 +/- 0.12 2.24 +/- 0.08 1.36 +/- 0.08 21.16 - 39.30 13.55 - 25.16 9.41 - 17.47 6.91 - 12.83 5.29 - 9.83 4.18 - 7.76 3.39 - 6.29 2.35 - 4.37 1.51 - 2.80 1.04-1.94 44.14 - 81.97 24.82 - 46.10 15.89 - 29.51 11.03 - 20.49 11.03 - 20.49 8.11 -15.05 7.06 -13.12 6.21 - 11.53 4.91 -9.11 4.91 -9.11 3.97 - 7.37 3.28 - 6.10 2.76 - 5.12 2,76 - 5.12 1.76-3.28 1.76 -3.28 1.23 - 2.28 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A2-1

TABLE A-3. In-House "Spike" Samples Concentration (pCi/L)a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 C Activity Limits d Acceptance SPW-111 SPW-298 W-11708 SPW-711 SPAP-881 SPAP-881 SPAP-883 SPMI-885 SPW-887 SPW-889 W-31808 W-31808 SPMI-885 SPMI-885 SPW-887 SPW-887 SPW-1282 W-40308 SPW-5580 SPW-1562 SPW-1560 SPW-1621 W-51508 W-51508 SPAP-2673 SPAP-2673 SPAP-2674 SPF-2745 SPF-2745 SPMI-2677 SPMI-2677A SPW-2677 SPW-2677 SPMI-2679 SPMI-2679 SPMI-2679 SPMI-2679A SPVE-2681 SPW-2683 SPW-2685 SPW-2689 1/14/2008 1/31/2008 1/17/2008 2/25/2008 3/11/2008 3/11/2008 3/11/2008 3/11/2008 3/11/2008 3/11/2008 3/18/2008 3/18/2008 3/24/2008 3/24/2008 3/24/2008 3/24/2008 4/2/2008 4/3/2008 4/7/2008 4/8/2008 4/10/2008 4/16/2008 5/15/2008 5/15/2008 6/2/2008 6/2/2008 6/2/2008 6/2/2008 6/2/2008 6/3/2008 6/3/2008 6/3/2008 6/3/2008 6/3/2008 6/3/2008 6/3/2008 6/3/2008 6/3/2008 6/2/2008 6/2/2008 6/2/2008 Tc-99 Ni-63 Ra-226 U-238 Cs-134 Cs-137 Gr. Beta e Sr-90 Sr-90 H-3 Gr. Alpha Gr. Beta Cs-134 Cs-137 Cs-134 Cs-137 U-238 Ra-226 H-3 Ra-228 Tc-99 Fe-55 Gr. Alpha Gr. Beta Cs-134 Cs-137 Gr., Beta e Cs-I 34 Cs-1 37 Cs-1 37 1-131 Cs-134 1-131(G)

Cs-134 Cs-1 37 1-131(G) 1-131 1-131(G)

Ni-63 H-3 C-14 32.20 +/- 0.85 213.55 +/- 3.07 11.34 +/- 0.43 33.56 +/- 1.74 19.29 +/- 1.53 114.04 +/- 3.03 54.56 +/- 0.12 45.93 +/- 1.60 38.82 +/- 1.60 67325.00 +/- 725.00 19.51 +/-0.40 47.20 +/- 0.42 40.93 +/- 1.55 61.36 +/- 2.82 40.68 +/- 1.44 58.52 +/- 2.93 41.30 +/- 1.78 15.17 +/-0.50 211.02 +/- 7.71 28.93 +/- 2.09 29.74 +/- 0.84 27205.80 +/- 982.90 24.01 +/- 0.41 47.97 +/- 0.41 17.39 +/- 1.32 106.82 +/- 3.42 53.57 +/- 0.13 0.34 +/- O.02 2.06 +/- 0.04 53.99 +/- 6.15 26.64 +/- 0.59 40.30 +/- 3.35 25.92 +/- 4.48 35.02 +/- 2.93 58.49 +/- 6.05 25.30 +/- 4.97 30.37 +/- 0.50 1.11 +/- 0.06 2151.70 +/- 10.22 64927.20 +/- 704.80 4405.40 +/- 15.21 32.34 212.58 12.69 41.70 20.09 113.90 51.64 45.13 45.13 67384.00 20.08 45.67 39.69 56.91 39.69 56.91 41.70 12.69 240.00 30.51 32.34 28370.00 20.08 45.68 18.60 113.30 51.40 0.37 2.27 56.66 28.58 37.21 28.58 37.21 56.66 28.58 28,58 0.95 2119.30 66540.80 4742.00 20.34 - 44.34 148.81 - 276.35 8.88 - 16.50 29.19 - 54.21 10.09 - 30.09 102.51 - 125.29 30.98 - 72.30 36.10 - 54.16 36.10 - 54.16 53907.20 - 80860.80 10.04 - 30.12 35.67 - 55.67 29.69 - 49.69 46.91 - 66.91 29.69 - 49.69 46.91 - 66.91 29.19 - 54.21 8.88 - 16.50 0.00 - 806.46 21.36 - 39.66 20.34 - 44.34 22696.00 - 34044.00 10.04 - 30.12 35.68 - 55.68 8.60 - 28:60 101.97 - 124.63 30.84 - 71.96 0.22 - 0.52 1.36 -3.18 46.66 - 66.66 16.58 - 40.58 27.21 -47.21 18.58 - 38.58 27.21 -47.21 46.66 - 66.66 18.58 - 38.58 16.58 - 40.58 0.57 - 1.33 1483.51 -2755.09 53232.64 - 79848.96 2845.20 - 6638.80 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A3-1

TABLE A-3. In-House "Spike" Samples Concentration (pCi/L)a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 Activity Limits' Acceptance W-81408 SPW-1 562 SPW-81808 W-81808 W-81808 W-1 12008 W-1 12008 SPAP-6839 SPAP-6839 SPAP-6841 SPW-6843 SPW-6845 SPW-6847 SPW-6849 SPW-6851 SPF-6859 SPF-6859 SPW-7059 SPMI-7061 8/14/2008 8/14/2008 8/18/2008 8/1812008 8/18/2008 11/20/2008 11/20/2008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/19/2008 12/19/2008 Ra-226 Ra-228 U-238 Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Cs-134 Cs-137 Gr. Beta e C-1 4 Fe-55 Tc-99 Ni-63 H-3 Cs-134 Cs-137 Sr-90 Sr-90 12.98 +/- 0.35 29.09 +/- 2.46 42.59 +/- 1.96 21.36 +/- 0.42 49.33 +/- 1.01 20.13 +/- 0.40 48.28 +/- 0.42 15.39 +/- 2.72 111.45 +/- 9.85 49.26 +/- 0.12 19377.50 +/- 55.27 7068.30 +/- 692.30 37.71 +/- 1.33 232.56 +/- 3.26 63664.00 +/- 8745.00 0.63 +/- 0.02 2.35 +/- 0.01 49.19 +/- 2.62 39.39 +/- 2.19 12.69 30.51 41.70 20.08 45.68 20.08 45.60 15.68 112.00 50.72 23708.00 6028.00 32.34 211.34 64674.00 0.63 2,24 44.33 44.33 8.88 - 16.50 21.36 - 39.66 29.19 - 54.21 10.04 - 30.12 35.68 - 55.68 10.04 - 30.12 35.60 - 55.60 5.68 - 25.68 100.80 - 123.20 30.43 - 71.01 14224.80 -33191.20 4822.40 - 7233.60 20.34 - 44.34 147.94 - 274.74 51739.20 - 77608.80 0.38 - 0.88 1.34 -3.14 35.46 - 53.20 35.46 - 53.20 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

' Liquid sample results are reported in pCi/Liter, air filters( pCi/filter), charcoal (pCi/m 3), and solid samples (pCi/g).

b Laboratory codes as follows: W (water), MI (milk), AP (air filter), SO (soil), VE (vegetation),

CH (charcoal canister), F (fish).

C Results are based on single determinations, d Control limits are established from the precision values listed in Attachment A of this report, adjusted to +/- 2a.

8 Control limits based on the laboratory limit, Attachment A ("Other Analyses").

NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.

A3-2

TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysisb Laboratory results (4.66a)

Acceptance Type LLD Activityc Criteria (4.66 a)

SPW-17 SPW-112 W-1 1408 SPAP-880 SPAP-880 SPW-888 W-31808 W-31808 SPMI-884 SPMI-884 W-40308 SPW-1 563 SPW-1561 SPW-1621 SPW-2451 SPW-2676 SPW-2676 SPW-2676 SPW-2677 SPW-2677 SPW-2677 SPF-2744 SPF-2744 SPW-2676 SPMI-2678 SPVE-2680 SPW-3581 W-80708 W-80708 W-81408 SPW-1563 SPW-81808 Water Water Water Air Filter Air Filter Water Water Water Milk Milk Water Water Water Water Water Water Water Water Water Water Water Fish Fish Water Milk Vegetation Water Water Water Water Water Water 1/3/2008 1/14/2008 1114/2008 3/11/2008 3/11/2008 3/11/2008 3/18/2008 3/18/2008 3/24/2008 3/24/2008 4/3/2008 4/8/2008 4/10/2008 4/16/2008 5/22/2008 6/2/2008 6/2/2008 6/2/2008 6/2/2008 6/2/2008 6/2/2008 6/2/2008 6/2/2008 6/3/2008 6/3/2008 6/3/2008 7/14/2008 8/7/2008 8/7/2008 8/14/2008 8/14/2008 8/18/2008 U-238 Tc-99 Ra-226 Cs-1 34 Cs-137 H-3 Gr. Alpha Gr. Beta Cs-134 Cs-1 37 Ra-226 Ra-228 Tc-99 Fe-55 U-238 Cs-134 Cs-1 34 Cs-137 Cs-134 1-131(G) 1-131(G)

Cs-134 Cs-137 1-131 1-131 1-131(G)

U-238 Gr. Alpha Gr. Beta Ra-226 Ra-228 U-238 0.09 4.70 0.05 0.91 1.13 159.99 0.42 0,72 2.79 3.36 0.04 0.57 4.77 668.50 0.21 2.03 3,60 2.38 2.78 3.49 5.25 5.48 4.83 0.18 0.22 0.01 0.10 0.63 1.43 0.06 0.79 0.18 0.01 +/- 0.07

-0.06 +/- 2.85 0.05 +/- 0.04

-78.90 +/- 80.40

-0.05 +/- 0.29 0.09 +/- 0.51 0.05 +/- 0.03 0.31 +/- 0.30

-3.42 +/- 2.85

-170.70 t 397.20 0.35 +/- 0.24 0.01 +/- 0.11 0.12 +/- 0.15 0.13 +/- 0.12

-0.02 +/- 0.44

-0.47 +/- 0.99 0.14 +/- 0.04 0.89 +/- 0.47 0.04 +/- 0.13 I

10 1

100 100 200 1

3.2 10 10 1

2 10 1000 I

10 10 10 10 20 20 100 100 0.5 0.5 20 1

1 3.2 1

2 1

A4-1

TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysisb Laboratory results (4.66or)

Acceptance Type LLD Activityc Criteria (4.66 a)

W-1 12008 W-1 12008 SPAP-6838 SPAP-6838 SPAP-6840 SPW-6842 SPW-6844 SPW-6846 SPW-6848 SPF-6858 SPF-6858 SPW-7058 SPW-7058 SPW-7058 SPMI-7060 SPMI-7060 SPMI-7060 SPMI-7060' Water Water Air Filter Air Filter Air Filter Water Water Water Water Fish Fish Water Water Water Milk Milk Milk Milk 11120/2008 11/20/2008 12/512008 12/5/2008 12/512008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/5/2008 12/19/2008 12/19/2008 12/19/2008 12/19/2008 12/19/2008 12/19/2008 Gr. Alpha Gr. Beta Cs-134 Cs-137 Gr. Beta C-14 Fe-55 Tc-99 Ni-63 Cs-134 Cs-137 Cs-134 Cs-137 Sr-90 Cs-134 Cs-1 37 1-131(G) 0.40 0.75 1.01 0.95 0.96 7.79 715.10 1.36 1.94 1.53 3.92 2.62 2.39 0.65 2.18 3.87 2.80 0.53 0.02 +/- 0.28

-0.16 +/- 0.52 2.69 +/- 0.64

-3.04 +/- 4.05 21.70 +/- 435.10

-0.47 +/- 0.82 3.08 +/- 1.23

-0.28 +/- 0.26 0.76 +/- 0.34 1

3.2 100 100 3.2 200 1000 10 20 100 100 10 10 1

10 10 20 1

12/19/2008 Sr-90 Liquid sample results are reported in pCilLiter, air filters( pCi/filter), charcoal (pCi/charcoal canister), and solid samples (pCi/kg).

b 1-131(G); iodine-131 as analyzed by gamma spectroscopy.

c Activity reported is a net activity result. For gamma spectroscopic analysis, activity detected below the LLD value is not reported.

d Low levels of Sr-90 are still detected in the environment. A concentration of (1-5 pCi/L) in milk Is not unusual.

A4-2

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance AP-8809, 8810 CF-42,43 CF-42, 43 DW-80020, 80021 U-169,170 SO-8836, 8837 SO-8836, 8837 SO-8836, 8837 SO-8836, 8837 DW-80045, 80046 DW-80045,80046 MI-138,139 LW-190,191 DW-8008, 8009 DW-8008, 8009 DW-80057, 80058 DW-80057, 80058 SWU-479,480 W-920, 921 SW-540, 541 SW-540, 541 DW-80155, 80156 DW-80155, 80156 DW-80165, 80166 DW-80166, 80167 DW-80166, 80167 DW-80166, 80167 W-1413,1414 DW-80189, 80190 DW-80189, 80190 MI-1006, 1007 MI-1006,1007 DW-80205, 80206 DW-80202, 80203 DW-80202, 80203 DW-80208, 80209 SG-1080, 1081 SO-1195, 1196 SO-1195, 1196 WW-1242, 1243 1/2/2008 1/2/2008 1/2/2008 1/7/2008 1/10/2008 1/14/2008 1/14/2008 1/14/2008 1/14/2008 1/15/2008 1/15/2008 1/15/2008 1/16/2008 1/16/2008 1/16/2008 1/21/2008 1/2112008 1/29/2008 2/4/2008 2/12/2008 2/12/2008 2/12/2008 2/12/2008 2/20/2008 2/2012008 2/20/2008 2/20/2008 3/312008 3/11/2008 3/11/2008 3/12/2008 3/1212008 3/14/2008 3/14/2008 3/14/2008 3/14/2008 3/18/2008 3/18/2008 3/18/2008 3/24/2008 412/2008 4/2/2008 4/2/2008 Be-7 Gr. Beta K-40 Gr. Alpha Beta-K40 Cs-137 Gr. Alpha Gr. Alpha K-40 Gr. Alpha Gr. Beta K-40 Gr. Beta Ra-226 Ra-228 Gr. Alpha Gr. Beta Gr. Beta Gr. Beta Gr. Alpha Gr. Beta Ra-226 Ra-228 Gr. Alpha Ra-226 Ra-228 Uranium Gr. Beta Ra-226 Ra-228 K-40 Sr-90 Gr. Alpha Ra-226 Ra-228 U-233/4 Pb-214 U-233/4 U-238 Gr, Beta Be-7 Gr. Alpha Gr. Beta 0.06 +/- 0.02 8.88 +/- 0.19 5.08 +/- 0.29 2.28 +/- 0.84 7.50 +/- 5.50 0,80 +/- 0.05 13.30 +/- 4.31 33.68 +/- 3.73 12.31 +/- 0.74 2.94 +/- 1.13 1.86 +/- 0.66 1262.40 +/- 81.70 2.85 +/- 1.07 2.77 +/- 0.20 3.95 +/- 0.74 6.77 +/- 0.66 13.83 +/- 0.97 4.49 +/- 1.13 4.20 +/- 1.30 2.75 +/- 1.16 6.46 +/- 1.11 2.55 +/- 0.22 1.86 +/- 0.70 1.51 +/- 0.90 0.40 +/- 0.09 1.44 +/- 0.52 0.69 +/- 0.25 7.50 +/- 3.00 4.41 +/- 0.30 1.99 +/- 0.65 1451.90 +/- 112.80 0.48 +/- 0.31 3.64 +/- 0.80 3.16 +/- 0.21 2.40 +/- 1.00 1.32 +/- 0.25 3.99 +/- 0.30 0.14 +/- 0.02 0.13 +/- 0.02 10.36 +/- 1.63 0.06 +/- 0.01 8.99 +/- 0.19 5.19 +/- 0.30 1.98 +/- 0.86 11.70 +/-5.10 0.75 - 0.05 15.58 +/- 4.10 29.21 + 3.10 12.96 +/- 0.73 3.41 +/- 1.04 1.36 +/- 0.63 1396.20 +/- 154.20 1.64 +/- 1.02 3.11 +/--0.22 3.96 +/- 0.77 7.91 +/- 1.73 14.78 +/- 1.01 3.13 +/- 1.14 3.30 +/- 1.30 4.01 +/- 1.18 6.71 +/- 1.03 2.01 +/- 0.16 1.53 +/- 0.67 0.80 +/- 1.05 0.46 +/- 0.09 1.42 +/- 0.57 0.69 +/- 0.26 3.70 +/- 2.60 4.09 +/- 0.25 2.17 +/- 0.66 1409.50 +/- 111.40 0.97 +/- 0.38 3.39 +/- 0.82 3.00 +/- 0.19 2.07 +/- 0.69 1.29 +/- 0.36 4.15 +/- 0.29 0.14 +/- 0.02 0.13 +/- 0.02 9.06 +/- 1.55 0.06 +/- 0.01 8.94 +/- 0.13 5.14 +/- 0.21 2.13 +/- 0.60 9.60 +/- 3.75 0.77 +/- 0.03 14.44 +/- 2.98 31.45 +/- 2.43 12.64 +/- 0.52 3.17 +/- 0.77 1.61 +/- 0.45 1329.30 +/- 87.25 2.24 +/- 0.74 2.94 +/- 0.15 3.96 +/- 0.53 7.34 +/- 0.92 14.31 +/- 0.70 3.81 +/- 0.80 3.75 +/- 0.92 3.38 +/- 0.83 6.59 +/- 0.76 2.28 +/- 0.14 1,70 +/- 0.48 1,16 +/- 0.69 0.43 - 0.06 1.43 +/- 0.39 0.69 +/- 0.18 5.60 +/- 1.98 4.25 - 0.20 2.08 + 0.46 1430.70 +/- 79.27 0.72 0 0.24 3.52 +/- 0.57 3.08 +/- 0.14 2.24 +/- 0.61 1.31 +/- 0.22 4.07 +/- 0.21 0.14 +/- 0.01 0.13 +/- 0.01 9.71 +/- 1.13 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass AP-1519,1520 W-1565,1566 W-1565,1566 0.07 +/- 0.01 0.82 +/- 0.64 3.73 +/- 0.86 0.08 +/- 0.01 1.58 +/- 0.72 5.51 +/- 1.09 0.08 +/- 0.01 1.20 +/- 0.48 4.62 +/- 0.69 A5-1

TABLE A-5. In-House "Duplicate" Samples Concentration (pCiIL)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance DW-80255, 80256 DW-80255, 80256 DW-80259,80260 DW-80301, 80302 DW-80301, 80302 SO-1913,1914 DW-80313, 80314 DW-80313, 80314 SWU-2087,2088 LW-2297,2298 LW-2321, 2322 BS-2063,2064 SG-2229, 2230 W-2792,2793 SG-2229, 2230 F-2850, 2851 DW-80376, 80377 DW-80376, 80377 MI-2363, 2364 SG-2752, 2753 SG-2752, 2753 SG-2752, 2753 SG-2752, 2753 SG-2752, 2753 DW-80389, 80390 DW-80389, 80390 DW-80392, 80393 DW-80394, 80395 BS-2490,2491 WW-2462, 2463 W-2826,2827 W-2826,2827 SG-3378, 3379 SG-3378, 3379 SG-3393, 3394 SG-3393, 3394 SG-3393, 3394 SG-3393, 3394 SG-3393, 3394 LW-2939, 2940 WW-3053, 3054 SW-3154,3155 4/8/2008 4/8/2008 4/8/2008 4/11/2008 4/11/2008 4/15/2008 4/16/2008 4/16/2008 4/29/2008 4/30/2008 4/30/2008 5/1/2008 5/5/2008 5/5/2008 5/5/2008 5/7/2008 5/9/2008 5/9/2008 5/1412008 5/14/2008 5/14/2008 5/14/2008 5/14/2008 5/14/2008 5/14/2008 5/14/2008 5/14/2008 5/14/2008 5/16/2008 5/19/2008 5/27/2008 5/27/2008 6/2/2008 6/2/2008 6/4/2008 6/4/2008 6/4/2008 6/4/2008 6/4/2008 6/12/2008 6/17/2008 6/24/2008 Ra-226 Ra-228 Gr. Alpha Ra-226 Ra-228 K-40 Ra-226 Ra-228 Gr. Beta Gr. Beta Gr. Beta Gr. Beta Ac-228 Gr. Beta Pb-214 Cs-137 Ra-226 Ra-228 K-40 Be-7 Cs-1 37 Gr. Alpha Gr. Beta K-40 Ra-226 Ra-228 Gr. Alpha U-233/4 Cs-137 H-3 Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Be-7 Cs-137 Gr. Alpha Gr. Beta K-40 Gr. Beta Gr. Beta Gr. Beta 0.19 +/- 0.08 1.79 +/- 0.57 3.39 +/- 0.82 0.47 +/- 0.09 1.02 +/- 0.42 12.79 +/- 0.73 3.39 +/- 0.22 4.27 +/- 0,72 2.20 +/- 0.60 1.41 +/- 0.43 1.33 +/- 0.54 13.71 +/- 2.06 26.25 +/- 2.70 7.20 +/- 2.30 23.28 +/- 0.30 3.37 +/- 0.21 0.94 +/- 0.13 2.05 +/- 0.57 1335.40 +/- 111.20 264.60 +/- 83.90 64.80 t 6.00 19.35 +/- 3.48 30.53 +/- 2.40 9121.90 +/- 191.80 2.99 +/- 0.36 2.87 +/- 0.68 19.94 +/- 1.30 2.03 +/- 0.27 6.81 +/- 1.20 158.61 +/- 80.90 3.47 +/- 2.23 10.67 +/- 1.92 6.51 +/- 1.15 16.23 +/- 0.95 0.82 +/- 0.23 0.07 +/- 0.01 18.96 +/- 3.49 30.01 +/- 2.49 9.78 +/- 0.30 1.46 +/- 0.59 4.28 +/- 0.83 2.15 +/- 1.01 0.28 +/- 0.11 1.32 +/- 0.55 3.62 +/- 0.82 0.47 +/- 0.09 0.82 +/- 0.45 13.88 +/- 0.85 3.28 +/- 0.21 5.14 +/- 0.77 3.50 +/- 0.90 1.02 +/- 0.40 1.23 +/- 0.54 17.60 +/- 2.49 24.90 +/- 2.55 7.00 +/- 2.50 23.54 +/- 0.33 3.16 +/- 0.19 1.07 +/- 0.13 1.40 +/- 0.51 1510.70 +/- 124.30 222.80 +/- 93.10 68.90 +/- 5.80 22,88 +/- 4.04 33.31 +/- 2.71 9183.70 +/- 194.20 2.58 +/- 0.31 1.73 +/- 0.57 17.89 +/- 1.26 2,54 +/- 0.39 6.76 +/- 1.23 205.63 +/- 83.06 4.22 +/- 2.20 9.43 +/- 1.76 7.83 +/- 1.32 15.76 +/- 1.06 0.66 +/- 0.33 0.07 +/- 0.01 16,96 +/- 3.34 30.17 +/- 2.56 10.00 +/- 0.28 1.74 +/- 0.59 5.27 +/- 0.91 2.79 +/- 0.97 0.24 +/- 0.07 1.56 +/- 0,40 3.51 +/- 0.58 0.47 +/- 0.06 0.92 +/- 0.31 13.34 +/- 0.56 3.34 +/- 0.15 4.71 +/- 0.53 2.85 +/- 0.54 1.22 +/- 0.30 1.28 +/- 0.38 15,66 +/- 1.62 25.58 +/- 1.86 7.10 +/- 1.70 23.41 +/- 0.22 3.27 +/- 0.14 1.01 +/- 0.09 1,73 +/- 0.38 1423.05 +/- 83.39 243.70 +/- 62.66 66.85 +/- 4.17 21.12 +/- 2.67 31.92 +/- 1.81 9152.80 +/- 136.47 2.79 +/- 0.24 2.30 +/- 0.44 18.92 +/- 0.91 2.29 +/- 0.24 6.78 +/- 0.86 182.12 +/- 57.97 3.84 +/- 1.57 10.05 +/- 1.30 7.17 +/- 0.88 16.00 +/- 0.71 0.74 +/- 0.20 0.07 +/- 0.01 17.96 +/- 2.42 30.09 +/- 1.79 9.89 +/- 0.21 1.60 +/- 0.42 4.77 +/- 0.61 2.47 +/- 0.70 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-2

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance BS-3245, 3246 BS-3245, 3246 XW-1080, 1081 XW-3786, 3787 G-3274, 3275 SL-3295, 3296 AP-3531, 3532 AP-3663, 3664 AP-3690, 3691 W-4333, 4334 W-4840, 4841 DW-80415, 80416 SG-3964, 3965 SG-3964, 3965 SG-3964, 3965 SG-3964, 3965 SG-3964, 3965 DW-80427, 80428 DW-80427. 80428 DW-80451, 80452 DW-80451, 80452 DW-80481, 80482 DW-80481 80482 MI-3842, 3843 MI-3892, 3893 DW-4067, 4068 SWT-4158, 4159 LW-4221, 4222 LW-4242, 4243 VE-4046. 4047 VE-4046, 4047 VE-4046, 4047 W-4821, 4822 W-4821,4822 W-4801,4802 W-4601, 4802 DW-80522, 80523 DW-80522, 80523 6/27/2008 6/27/2008 6/30/2008 6/30/2008 7/1/2008 7/1/2008 7/1/2008 7/2/2008 7/2/2008 7/7/2008 7/7/2008 7/7/2008 7/9/2008 7/9/2008 7/9/2008 7/9/2008 719/2008 7/9/2008 7/9/2008 7/15/2008 7/15/2008 7/16/2008 7/16/2008 7/21/2008 7/28/2008 7/29/2008 7/29/2008 7/31/2008 7/31/2008 8/4/2008 8/4/2008 8/4/2008 8/4/2008 8/4/2008 8/5/2008 8/5/2008 8/5/2008 8/5/2008 Co-60 Cs-137 Fe-55 Fe-55 Gr. Beta Gr. Beta Be-7 Be-7 Be-7 Gr. Beta Gr. Beta Ra-226 Be-7 Cs-137 Gr. Alpha Gr. Beta K-40 Ra-226 Ra-228 Ra-226 Ra-228 Ra-226 Ra-228 K-40 K-40 Gr. Beta Gr. Beta Gr. Beta Gr. Beta Be-7 Gr. Beta K-40 Gr. Alpha Gr, Beta Gr. Alpha Gr. Beta Ra-226 Ra-228 108.84 +/- 44.14 952.18 +/- 52.78 2.96 +/- 0.32 2.96 + 0.32 7.65 + 0.24 3.76 - 0.24 0.10 +0.01 0.08 +/- 0.01 0.07 +/- 0.01 7.20 +/- 1.90 6,70 +/- 1.60 2.81 +/- 0.47 1.35 +/- 0.23 0,04 +/- 0.01 23.17 +/- 3.39 28.99 +/- 2.12 6.86 +/- 0.19 3.25 +/- 0.24 2.65 +/- 0.67 1.02 + 0.10 1.09 - 0.62 1.20 -0.13 1.69 +/- 0.68 1282.60 +/- 108.30 1371.50 +/- 102.90 10.46 + 2.37 1.58 + 0.45 1.35 _ 0.56 1.36 40.56 0.77 + 0.13 8,81 + 0.36 5.17 +/-0.34 1.70 +/- 0,80 3.90 +/- 0.80 4.40 +/- 2.40 13.20 +/- 1.30 0.50 +/- 0.12 1.23 +/- 0.60 91.10 +/- 22.32 941.56 +/- 13.61 2.71 +/- 0.30 2.71 +/- 0.30 7.44 +/- 0.24 3.64 +/- 0.24 0.08 +/- 0.01 0.08 +/- 0.02 0.07 +/- 0.01 7.70 +/- 1.70 6.70 +/- 1.80 2.00 +/- 0.34 1.51 +/- 0.22 0.04 +/- 0.01 18.76 +/- 3.24 29.25 +/- 2.31 6.84 +/- 0.17 3.27 + 0.20 3.25 + 0.72 0.96 - 0.12 1.14 +/- 0,60 1.40 +/- 0.14 1.65 +/-.0.77 1379.00 +/- 111.40 1501.20 +/- 111.80 14.25 +/- 2.78 1.80 +/- 0.47 0.91 +/- 0.52 1.18 +/- 0.53 0.82 +/- 0.19 8.34 +/- 0.31 5.33 +/- 0.42 1.70 +/- 0.90 3.70 +/- 0.90 4.80 +/- 2.30 14.50 +/- 1.40 0.28 +/- 0.12 1.09 +/- 0.57 99.97 +/- 24.73 946.87 +/- 27.25 2.84 +/- 0.22 2.84 +/- 0.22 7.55 +/- 0.17 3.70 +/- 0.17 0.09 +/- 0.01 0.08 +/- 0.01 0.07 +/- 0.01 7.45 +/- 1.27 6.70,+/- 1.20 2.41 +/- 0.29 1.43 +/- 0.16 0.04 +/- 0.00 20.97 +/- 2.34 29.12 +/- 1.57 6.85 +/- 0.13 3.26 +/- 0.16 2.95 +/- 0.49 0.99 +/- 0.08 1.12 +/- 0.43 1.30 +/- 0.10 1.67 +/- 0.51 1330.80 +/- 77.68 1436.35 +/- 75.97 12.36 +/- 1.83 1.69 +/- 0.33 1.13 +/- 0.38 1.27 +/- 0.38 0.80 +/- 0.12 8.58 +/- 0.24 5.25 +/- 0.27 1.70 +/- 0.60 3.80 +/- 0.60 4.60 +/- 1.66 13.85 +/- 0.96 0.39 +/- 0.08 1.16 +/- 0.41 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-3

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance DW-80531, 80532 DW-80534, 80535 DW-80534, 80535 SG-4584 4585 SG-4584, 4585 SG-4584,4585 SG-4584, 4585 SG-4573, 4574 SG-4573, 4574 SG-4584, 4585 SG-4584, 4585 DW-80547, 80548 DW-80551, 80552 DW-80553, 80554 DW-80553, 80554 DW-80566, 80567 DW-80566, 80567 VE-4647, 4648 SL-4690, 4691 ME-4732, 4733 ME-4732, 4733 SG-5180, 5181 SG-5180, 5181 SG-5180, 5181 SG-5180, 5181 SG-5180, 5181 SG-5187, 5188 SG-5187, 5188 SG-5193, 5194 SG-5193, 5194 DW-4871, 4872 VE-5022, 5023 DW-5337, 5338 WW-4977, 4978 BS-5088, 5089 DW-80584, 80585 DW-80584, 80585 DW-80579,80580 DW-80579,80580 DW-80579, 80580 G-5389,5390 G-5389,5390 G-5389,5390 8/5/2008 8/5/2008 8/5/2008 8/6/2008 8/6/2008 8/6/2008 8/6/2008 8/13/2008 8/13/2008 8/13/2008 8/13/2008 8/13/2008 8/13/2008 8/13/2008 8/13/2008 8/20/2008 8/20/2008 8/27/2008 9/2/2008 9/2/2008 9/2/2008 9/3/2008 9/3/2008 9/3/2008 9/3/2008 9/3/2008 9/312008 9/3/2008 9/3/2008 9/3/2008 9/5/2008 9/10/2008 9/10/2008 9/17/2008 9/19/2008 9/19/2008 9/19/2008 9/25/2008 9/25/2008 9/25/2008 10/1/2008 10/1/2008 10/1/2008 Gr. Alpha Ra-226 Ra-228 Be-7 Cs-137 K-40 Ra-226 Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Alpha U-233/4 Ra-226 Ra-228 Ra-226 Ra-228 K-40 Gr. Beta Gr. Beta K-40 Be-7 Cs-137 Gr. Alpha Gr. Beta K-40 Be-7 K-40 Gr. Alpha Gr. Beta 1-131 K-40 Gr. Beta Gr. Beta K-40 U-233/4 U-238 Gr. Alpha Ra-226 Ra-228 Be-7 Gr. Beta K-40 18.90 +/- 1.86 3.01 +/- 0.18 2.24 +/- 0.59 7.11 +/- 0.20 0.05 +/- 0.01 7.88 +/- 10.18 3.94 +/- 0.18 240.72 +/- 8.74 201,60 +/- 4.28 14.07 +/- 3.10 22.08 +/- 2.36 3.33 +/- 1.11 2.57 +/- 0.48 0.92 +/- 0.14 2.20 +/- 0.61 1.10 +/--0.11 2.01 + 0.58 1.97 +/--0.17 2.28 t 0.25 2.86 +/- 0.09 2.44 +/- 0.37 15.50 - 0.43 0.07 + 0.01 18.74 + 3.33 29.19 +/-2.10 8.55 +/- 0.32 6.18 0 0.54 7.16 + 0.60 5.80 +/- 1.30 15.60 _ 1.10 1.15 +/--0.27 1.27 + 0.14 3.00 + 1.07 3.71 +/- 1.10 10493 +/-607 3.01 +/- 0.52 0.70 +/- 0.25 10.69 +/- 1.31 3.13 +/- 0.22 3.03 +/- 0.73 1.49 +/- 0.32 10.86 +/- 0.24 7.42 +/- 0,67 17.80 +/- 1.96 3.33 +/- 0.18 2.12 +/- 0.59 7.44 +/- 0.37 0.04 +/- 0.01 8.02 +/- 0.21 3.74 +/- 0.22 251.53 +/- 9.56 206.88 +/- 4.71 12.97 +/- 3.04 23.02 +/- 2.34 3.88 +/- 1.07 2.13 +/- 0.46 1.21 + 0.17 1.64 + 0.56 1.10 +-0.10 1.74 - 0.58 2.00 + 0.21 2.35 + 0.24 2.70 - 0.09 2.82 +/- 0.51 15.54 +/-0.38 0.07 +/- 0.01 17.61 +/- 3.15 28.49 +/- 2.15 8.11 +/- 0.27 5.90 +/- 0.77 7.29 +/- 0.60 7.00 +/- 1.50 15.60 + 1.10 1.16 +/- 0.31 1.11 + 0.06 2.19 +/- 1.05 2.32 +/- 1.11 10299 +/-470 2.44 +/- 0.47 0.27 - 0.18 12.84 +/- 1.51 2.89 +/- 0.21 1.98 +/- 0.69 1.36 +/- 0.28 11.18 +0.25 8.06 + 0.63 18.35 +/- 1.35 3.17 +/- 0.13 2.18 +/- 0.42 7.27 +/- 0.21 0.04 +/- 0.00 7.95 +/- 5.09 3.84 +/- 0.14 246.13 +/- 6.48 204.24 +/- 3.18 13.52 +/- 2.17 22.55 +/- 1.66 3.61 +/- 0.77 2.35 +/- 0.33 1.07 +/- 0.11 1.92 +/- 0,41 1.10 +/- 0.07 1.88 +/- 0.41 1.99 +/- 0.14 2.32 +/- 0.17 2.78.+/- 0.06 2,63 +/- 0.32 15.52 +/- 0.29 0.07 +/- 0.01 18.18 +/- 2.29 28.84 +/- 1.50 8.33 +/- 0.21 6.04 +/- 0.47 7.23 +/- 0.42 6.40 +/- 0.99 15.60 - 0.78 1.16 +/- 0.21 1.19 +/- 0.08 2.60 +/- 0.75 3.01 + 0.78 10396 +/- 384 2.73 +/- 0.35 0.49 +/- 0.15 11.77 +/- 1.00 3.01 +/- 0.15 2.51 +/- 0.50 1.43 +/- 0.21 11.02 +/- 0.17 7.74 +/- 0.46 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-4

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance AP-5814, 5815 SG-6111, 6112 SG-6111, 6112 DW-80592, 80593 DW-80594, 80595 DW-80650, 80651 DW-80650, 80651 DW-80629, 80630 DW-80629, 80630 DW-80663, 80664 MI-5572, 5573 MI-5603, 5604 DW-80676, 80677 DW-80676, 80677 DW-80676, 80677 SW-80687, 80688 DW-80729, 80730 DW-80729, 80730 DW-80738, 80739 DW-80747, 80748 DW-80747, 80748 BS-6271, 6272 SS-6593, 6594 MI-7046, 7047 DW-80698, 80699 DW-80698, 80699 SW-7281, 7282 10/1/2008 10/6/2008 10/6/2008 10/7/2008 10/7/2008 10/8/2008 10/8/2008 10/13/2008 10/13/2008 10/13/2008 10/14/2008 10/14/2008 10120/2008 10/20/2008 10/20/2008 10/22/2008 10/30/2008 10/30/2008 10/31/2008 10/31/2008 10/31/2008 11/3/2008 11/19/2008 12/16/2008 12/23/2008 12/23/2008 12/30/2008 Be-7 Gr. Alpha Gr. Beta Gr. Alpha Ra-228 Gr. Alpha Gr. Beta Ra-226 Ra-228 Gr. Alpha K-40 K-40 Gr. Alpha Ra-226 Ra-228 Gr. Alpha Gr. Alpha Gr. Beta U-233/4 Ra-226 Ra-228 Gr. Beta K-40 K-40 Ra-226 Ra-228 Gr_ Beta 0.08 +/- 0.01 9.34 +/- 1.82 17.46 +/- 1.46 2.30 +/- 1.14 1.41 +/- 0.55 1.30 +/- 0.86 2.92 +/- 0.69 3.12 +/- 0.18 2.71 +/- 0.80 5.91 +/- 1.70 1391.00 +/- 97.39 1412.80 +/- 109.30 12.20 +/- 1.48 5.04 +/- 0.25 5.87 +/- 0.86 3.42 +/- 1.03 8.40 +/- 1.45 16.94 +/- 1.45 2.94 +/- 0.50 0.60 +/- 0.09 1.33 +/- 0.59 12.26 +/- 1.69 12.35 +/- 0.57 1380.10 +/- 109.80 3.13 +/- 0.22 5.48 + 0.91 0.87 - 0.54 0.08 +/- 0.01 8.95 +/- 1.67 18.86 +/- 1.35 1.57 +/- 0.88 1.22 +/- 0.50 0.12 +/- 0.79 3.03 +/- 0.64 2.87 +/- 0.17 3.28 +/- 0.81 3.14 +/- 1,44 1443.90 +/- 110.60 1413.80 +/- 110.50 11.87 +/- 1.54 5.10 +/- 0.25 6.98 +/- 0.95 2.98 +/- 1.01 7.76 +/- 2.00 15.41 +/- 1.37 3.06 +/- 0.63 0.50 +/- 0.08 1.38 +/- 0.60 13.78 +/- 1.84 13.10 +/- 0.76 1477.30 +/- 98:32 3.21 +/- 0.23 5.86 +/- 0.93 1.35 +/- 0.54 0.08 +/- 0.01 9.15 +/- 1.24 18.16 +/- 0.99 1.94 +/- 0.72 1.32 +/- 0.37 0.71 +/- 0.58 2.98 0 0.47 3.00 +/-0.12 3.00 + 0.57 4.53. 1.11 1417.45 +/- 73.68 1413,30 -+77.71 12.04 + 1.07 5.07 +/- 0.18 6.43 + 0.64 3.20 +/- 0.72 8.08 + 1.24 16.18 +/- 1.00 3.00 +/- 0,40 0.55 +/- 0.06 1.36 +/- 0.42 13.02 +/- 1.25 12.73 +/- 0.48 1428;70 +/- 73.69 3.17 +/- 0.16 5.67 +/- 0.65 1.11 +/- 0.38 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Duplicate analyses are performed on every twentieth sample received in-house. Results are not listed for those analyses with activities that measure below the LLD.

a Results are reported in units of pCi/L, except for air filters (pCi/Iilter), food products, vegetation, soil, sediment (pCi/g),

A5-5

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.

Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STW-1137 STW-1137 STW-1137 STW-1137e STW-1 1378 STW-1 137 STW-1137 STW-1137 STW-1 137 STW-1137 STW-1137 STW-1137 STW-1 137 STW-1137 STW-1137 STW-1137 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01101108 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 Am-241 Co-57 Co-60 Cs-134 Cs-137 Fe-55 H-3 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 STW-1138 01/01/08 Gr. Alpha STW-1138 01/01/08 Gr. Beta STAP-1139 STAP-1 139 STAP-1 139 STAP-1 139 STAP-1139 STAP-1 139 STAP-1 139 STAP-1 139 STAP-1 139e STAP-1 1398 STAP-1 139 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01108 Co-57 Co-60 Cs-134 Cs-1 37 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 1.27 - 0.06 23.80 +/- 0,60 8.60 +/- 0.50

-0.021 + 0.10 0.00 + 0.10 32.60 + 11.60 515.10 +/- 12.70 12.90 +/- 0.80 29.50 +/- 2.30 0.60 t 0.06 0.019 +/- 0.015 12.00 +/- 1.50 9.40 +/- 1.70 3.37 t 0.20 3.63 +/- 0.21 16.90 +/- 1,40 0.96 +/- 0.14 2.30 +/- 0.15 3.90 +/- 0.07 1.43 +/- 0.07 2.59 +/-+0.16 3.05 +/- 0.12 0.43 +/- 0.58 0.080 +/- 0.016 0.12 +/- 0.02 1.30 +/- 0.27 0.43 +/- 0.03 0.44 +/- 0.03 2.36 +/- 0.18 0.11 +/- 0.03 0.34 +/- 0.04 8.30 +/- 0,18 3.03 +/- 0.13 6.53 +/- 0.29 3.90 +/- 0.19 5,43 +/- 0.21 0.033 +/- 0.10 1.23 22.80 8.40 0.00 0.00 36.50 472.00 12.10 30.70 0.73 0.01 11.40 11,20 3.63 3.74 16.30 1.40 2.43 0.86-1.60 16.00 - 29,60 5.88 - 10.92

-1.00 - 1.00

-1.00-1.00 25.60 - 47.50 330.00 - 614.00 8.50 -15.70 21.50 - 39.90 0.51 - 0.95 0.00 - 1.00 7.98 - 14.82 7.80 - 14.60 2.54 - 4.72 2.62 - 4.86 11.40 - 21.20 0.00 - 2.80 1.22 -3.65 3.55 1.31 2.52 2.70 0.00 0.11 0.11 1.55 0.22 0.23 2.04 0.35 0.29 6.89 2.77 6.28 3.41 4.74 0.00 2.49 - 4.62 0.92 - 1.70 1.76 -3.28 1.89 -3.51 0.00- 1.00 0.07 - 0.14 0.08 - 0.15 1.08 - 2.01 0.15 -0.28 0.16 - 0.29 1.43 -2.65 0.00 - 0.70 0.14 - 0.43 4.82 - 8.96 1.94-3.60 4.40 -8.16 2.39 - 4.43 3.32 -6.16 0.00 - 1.00 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

  • Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass STAP-1 140 01/01/08 Gr. Alpha STAP-1140 01/01/08 Gr. Beta STVE-1 141 STVE-1141 STVE-1 141 STVE-1141 STVE-1141 STVE-1 141 01/01/08 01/01/08 01101/08 01/01/08 01/01/08 01/01/08 Co-57 Co-60 Cs-1 34 Cs-137 Mn-54 Zn-65 A6-1

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.

Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STSO-1 142 STSO-1 142 STSO-1142 STSO-1 142 STSO-1 142 STSO-1142 STSO-I 142 STSO-1142 STSO-1 142 STSO-1 142 STSO-1 142 STSO-1 158 STSO-1 158 STSO-1158 STSO-1 158 STSO-1158 STSO-1 158 STSO-1158 STSO-1 158 STSO-1158 STSO-1158 STSO-1158 STSO-1 158 t STSO-1 158 STSO-1158 STVE-1 159 STVE-1 159 STVE-1 159 STVE-1 159 STVE-1 159 STVE-1159 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 01/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 08/01/08 Co-57 Co-60 Cs-I 34 Cs-137 Mn-54 Ni-63 Pu-238 Pu-239/40 U-233/4 U-238 Zn-65 Am-241 Co-57 Co-60 Cs-134 Cs-137 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-238 Zn-65 Co-57 Co-60 Cs-134 Cs-137 Mn-54 Zn-65 483.00 +/- 3.00 3.00 +/- 0.80 896.50 +/- 7.40 624.40 +/- 4.10 667.20 +/- 3.80 536.00 t 15.50 78.60 +/- 4.80 89.10 +/- 4.50 134.41 +/- 5.40 139.00 +/- 5.50 0.093 +/- 0.91 57.73 +/- 4.78 353.02 +/- 2.01 151.99 +/- 1.58 499.72 +/- 2.65 2.54 +/- 0.25 643.94 t 15.50 452.14 +/- 2.96 803.09 +/- 17.01 0.12 +/- 0.54 60.88 +/- 5.89 1.95 +/- 2.04 337.00 +/- 17.30 315.67 +/- 11.29 0.10 +/- 2.04 8.52 +/- 0.23 5.08 +/- 0.19 5.26 +/- 0.18 0.01 +/- 0.14 6.39 +/- 0.28 7.73 +/- 0.45 421.00 2.90 854.00 545.00 570.00 640.00 72.80 90 10 142.00 148.00 0.00 69.10 333.00 145.00 581.00 2.80 570.00 415.00 760.00 0.00 55.60 0.00 335.00 303.00 0.00 7.10 4.70 5.50 0.00 5.80 6.90 295.00 - 547.00 0.00 -5.00 598.00 - 1110.00 382.00 - 709.00 399.00 - 741.00 448.00 -832.00 51.00 -94.60 63.10 -117.10 99.00 - 185.00 104.00 - 192.00 0.00 -1.00 48.40 - 89.80 233.00 - 433.00 102.00 - 189.00 407.00 - 755.00 0.00 -5.00 399.00 -741.00 291.00 -540.00 532.00 - 988.00 0.00 -5.00 38.90 -72.30 0.00-5.00 235.00 - 436.00 212.00 - 394.00 0.00 - 5.00 5.00 - 9.20 3.30 -6.10 3.90 - 7.20 0.00-1.00 4.10 -7.50 4.80 - 9.00 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A6-2

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.

Concentration b Known Control -

Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STW-1162 9 08/01/08 Am-241 0.20 +/- 0.06 0.00 0.00 -0.10 Fail STW-1 162 08/01/08 Co-57 0.03 +/- 0.16 0.00 0.00 - 5.00 Pass STW-1162 08/01/08 Co-60 11.27 +/-_0.23 11.60 8,10-15.10 Pass STW-1162 08/01/08 Cs-134 17.93 +/- 0.52 19.50 13.70 - 25.40 Pass STW-1162 08/01/08 Cs-137 23.72 +/- 0.43 23.60 16.50 - 30.70 Pass STW-1162 08/01/08 Fe-55 43.36 +/- 16.81 46.20 32.30 - 60.10 Pass STW-1162 08/01/08 H-3 385.15 +/- 8.93 341.00 239.00 - 443.00 Pass STW-1162 08/01/08 Mn-54 13.87 +/- 0.37 13.70 9.60 -17.80 Pass STTW-1162 h 08/01/08 Ni-63 10.77 +/- 2.01 0.00 0.00 -5.00 Fail STW-1 162 08/01/08 Pu-238 0.33 +/- 0.06 0.50 0.40 - 0.70 Fail STW-1162 08/01/08 Pu-239/40 0.14 +/- 0.15 0.00 0.00 -0.20 Pass STW-1162 08/01/08 Sr-90 6.49 +/- 1.12 6.45 4.52 - 8.39 Pass STW-1162 08/01/08 Tc-99 1.80 +/- 0.62 3.76 2.63 -4.89 Fail STW-1162 08/01/08 U-233/4 3.33 +/- 0.18 3.44 2.41 - 4.47 Pass STW-1162 08/01/08 U-238 3.38 +/- 0.18 3.55 2.49 -4.62 Pass STW-1162 08/01/08 Zn-65 17.64 +/- 0.61 17.10 12.00 -22.20 Pass STW-1163 08/01/08 Gr. Alpha 0.08 +/- 0.04 0.00 0.00 -0.56 Pass STW-1 163 08/01/08 Gr. Beta 0.12 +/- 0.05 0.00 0.00-1.85 Pass Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the Department of Energy's Mixed Analyte Performance Evaluation Program, Idaho Operations office, Idaho Falls, Idaho b Results are reported in units of Bq/kg (soil), Bq/L (water) or Bq/total sample (filters, vegetation).

Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).

d MAPEP results are presented as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP.

e The results of a repeat analysis were still unacceptable. A spiked air filter was prepared (known activity 4.17 pCi/filter) to verify the methodology; results of the spike analysis were acceptable, 4.64 pCi/filter.

f Corrected result. An error in calculation was found.

Included in the testing series as a "false positive". Result of reanalysis, 0.04 +/- 0.01 Bq/L.

hIncluded in the testing series as a "false positive". Result of reanalysis, 3.78 +/- 2.03 Bq/L.

'The reason for the deviation is unknown. Result of the original sample recount: 0.47 +/- 0.07 BqIL.

The analysis was then repeated from the beginning. Result of reanalysis: 0.51 + 0.07 Bq/L.

'The lower result was due to a higher than average background count used in the calculation. Average background result:, 4.11 +/- 0.6 A6-3

TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCI/L)

Lab Code b Date Analysis Laboratory ERA Control Result C Result d Limits Acceptance STAP-1 143 STAP-1 143 STAP-1 143 STAP-1 143 STAP-1 143 STAP-1143 STAP-1 143 STAP-1 143 STAP-1 143 STAP-1 143 STAP-1 143 STAP-1 143 STAP-1143 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 Am-241 Co-60 Cs-134 Cs-137 Fe-55.

Mn-54 Pu-238 Pu-239/40 Sr-90 U-23314 U-238 Uranium Zn-65 STAP-1 144 03/24/08 Gr. Alpha STAP-1 144 03/24/08 Gr, Beta 60.48 +/- 3.52 650.72 +/- 3.00 467.50 +/- 5.53 1375.90 +/- 25.41 145.60 +/- 28.94 0.00 +/- 0.00 53.65 +/- 1.54 70.44 +/- 3.11 157.60 +/- 7.70 62.15 +/- 3.41 64.11 +/-*3.29 128.40 +/- 3.29 889.90 +/- 15.90 13.08 +/- 1.09 99.90 +/- 3.09 1269.02 +/- 36.81 1268.50 +/- 85.80 1407.10 +/- 56.64 2145.50 +/- 305.63 5219.70 +/- 90.30 5427.30 +/- 102.94 6346.60 +/- 201.80 11052.70 +/- 181.80 0.00 +/- 0.00 1198.20 +/- 96.58 2253.30 +/- 291.60 6407.00 +/- 277.00 2421.80 +/- 321.00 1227.93 +/- 91.52 1319.90 +/- 48.81 2592.00 +/- 140.50 2936.20 +/- 73.50 50.1 730.0 523.0 1450.0 241.0 0.0 46.8 64.1 152.0 66.7 66.2 136.0 872.0 8.8 92.2 1180.0 1230.0 1360.0 1790.0 5130.0 5640.0 6010.0 11000.0 0.0 1080.0 2020.0 5360.0 2030.0 2050.0 2030.0 4180.0 2660.0 29.3 -68.7 565.0 -912.0 341.0 -647.0 1090.0 - 1900.0 106.0 -375.0 0.0 - 10.0 32.1 -61.5 46.5 - 83.0 66.9 -236.0 42.0 - 98.8 42.4 - 94.0 69.5 -216.0 604.0 - 1210.0 4.56 -13.2 56.80 - 135.0 757.0 -1660.0 735.0 - 1580.0 357.0 - 2030.0 1100.0 -2570.0 3730.0 -6890.0 3630.0 - 6790.0 4600.0 -7810.0 7980.0 - 14900.0 0.0 -10.0 697.0 - 1520.0 1210.0 - 3010.0 1940.0 -8750.0 644.0 -3870.0 1240.0 - 2580.0 1240.0 - 2580.0 2380.0 -5640.0 2110.0 -3570.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass STSO-1 145 STSO-1145 STSO-1 145 STSO-1 145 STSO-1145

.STSO-1 145 STSO-1145 STSO-1 145 STSO-1 145 STSO-1145 STSO-1 145 STSO-1145 STSO-1 145 STSO-1 145' STSO-1 145 STSO-1 145 STSO-1 145 03/24/08 03/24108 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 Ac-228 Am-241 Bi-212 Bi-214 Co-60 Cs-1 34 Cs-137 K-40 Mn-54 Pb-212 Pb-214 Sr-90 Th-234 U-233/4 U-238 Uranium Zn-65 A7-1

TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCi/L)

Lab Code b Date Analysis Laboratory ERA Control Result c Result d Limits Acceptance STVE-1 146 STVE-1 146 STVE-1 146 STVE-1 146 STVE-1 146 STVE-1146 STVE-1146 STVE-1 146 STVE-1 146 STVE-1 146 STVE-1 146 STVE-1 146 STW-1147 STW-1 147 STW-1 147 STW-1147 STW-1147 STW-1147 STW-1 147 STW-1147 STW-1147 STW-1 147 STW-1147 STW-1 147 STW-1 147 STW-1 120 STW-1120 03/24/08 03/24108 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03124/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/24/08 03/19/07 03/19/07 Am-241 Cm-244 Co-60 Cs-134 Cs-137 K-40 Mn-54 Sr-90 U-233/4 U-238 Uranium Zn-65 Am-241 Co-60 Cs-134 Cs-137 Fe-55 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium Zn-65 Uranium Zn-65 1261.50 +/- 73.90 1152.50 +/- 57.44 912.41 +/- 13.59 1547.70 +/- 38.81 1163.80 +/- 20.62 22186.00 +/- 339.40 0.00 +/- 0.00 3825.90 +/- 140,66 2753.30 +/- 227.90 2697.10 +/- 143.20 5586.10 +/- 455.20 1676.80 +/- 43.00 97.56 +/- 1.02 1430.00 +/- 33.33 730.18 +/- 33.39 1947.80 +/- 13.80 1422.70 +/- 172.16 0.00 + 0.00 144.16 +/- 4.54

.82.16 +/- 2.50 512.03 +/- 43.37 74.40 +/- 1.20 75.10 +/- 1.35 152.10 +/- 2.55 708.90 +/- 29.00 339.60 +/- 10.66 2009.00 +/- 36,40 1260.0 1200.0 888.0 1540.0 1100.0 24600.0 0.0 4130,0 3070.0 3050.0 6260.0 1430.0 90.9 1420.0 751.0 1990.0 2080.0 0.0 135.0 80.7 512.0 81.0 80.3 165.0 694.0 391.0 1910.0 718.0 - 1730.0 591.0 - 1870.0 600.0 - 1280.0 882.0 -2130.0 807.0 - 1530.0 17700.0 - 34800.0 0.0 - 10.0 2310.0 - 5480.0 2110.0 - 4070.0 2140.0 - 3850.0 4300.0 - 8080.0 1030.0 - 1960.0 62.0 - 124.0 1240.0 - 1680.0 555.0 - 862.0 1690.0 - 2380.0 1210.0 - 2780.0 0.0 - 10.0 102.0 - 168.0 62.4 -99.8 325.0 -684.0 61.0 - 104.0 61.3 -99.5 119.0 - 220.0 588.0 - 865.0 282.0 - 521.0 1600.0 - 2410.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass a Results obtained by Environmental, Inc., Midwest Laboratory as a participant In the crosscheck program for proficiency testing administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurements Laboratory Quality Assessment Program (EML).

b Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).

c Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

d Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

e Included in the testing series as a "false positive". No activity expected.

f The analysis was repeated by leaching and total dissolution methods. Total dissolution yielded results within expected range.

Results of the reanalysis: U-233,4, 1655 +/- 95 pCi/kg. U-238 1805 +/- 97 pCi/kg.

A7-2

APPENDIX B DATA REPORTING CONVENTIONS B-1

Data Reporting Conventions 1.0. All activities, except gross alpha and gross beta, are decay corrected to collection time or the end of the collection period.

2.0. Single Measurements Each single measurement is reported as follows:

x +/- s where:

x = value of the measurement; s = 2s counting uncertainty (corresponding to the 95% confidence level).

In cases where the activity is less than the lower limit of detection L, it is reported as: <L, where L = the lower limit of detection based on 4.66s uncertainty for a background sample.

3.0. Duplicate analyses 3.1 Individual results:

For two analysis results; xl +/- Sl and x2 +/- s2 Reported result:

x +/- s; where x = (112) (xi + X2) and s = (1/2) S + s2 3.2.

Individual results:

<1, <2 Reported result: <L, where L = lower of L1 and L2 3.3.

Individual results:

x +/- s, <L Reported result:

x +/- s if x ZL; <L otherwise.

4.0. Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for example, an annual standard deviation would not be the average of quarterly standard deviations. The average x and standard deviation s of a set of n numbers x1, x2... xn are defined as follows:

I x____

2_

n

)x sn 4.2 Values below the highest lower limit of detection are not included in the average.

4.3 If all values in the averaging group are less than the highest LLD, the highest LLD is reported.

4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error is reported.

4.5 In rounding off, the following rules are followed:

4.5.1.

If the number following those to be retained is less than 5, the number is dropped, and the retained number s are kept unchanged. As an example, 11.443 is rounded off to 11.44.

4.5.2. If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 11.45.

B-2

POINT BEACH NUCLEAR PLANT APPENDIX C Sampling Program and Locations C-1

POINT BEACH NUCLEAR PLANT Locations Collection Type Analysis Sample Type No.

Codes (and Type)'

(and Frequency)b (and Frequency)b Airborne Filters Airborne Iodine Ambient Radiation (TLD's)

Lake Water 6

E-1-4, 8, 20 6

E-1-4, 8, 20 22 E-1-9, 12, 14-18, 20, 22-32, 34-36, 38,39 5

E-1, 5, 6, 33 Well Water Vegetation Shoreline Silt Soil Milk Algae 1

8 5

8 3

2 E-10 E-1-4, 6, 9, 20 E-1, 5, 6, 12, 33 E-1-4, 6, 8, 9, 20 E-11, 40, 21 E-5, 12 Weekly Weekly Quarterly Monthly Quarterly 3x / year as available 2x year 2x I year Monthly 3x I year as available 3x I year as available GB, GS, on QC for each location 1-131 Ambient Gamma GB, GS, 1-131 on MC H-3, Sr-89-90 on QC GB, GS, H-3, Sr-89-90, 1-131 GB, GS GB, GS GB, GS GS, 1-131, Sr-89-90 GB, GS GB, GS (in edible portions)

Fish 1

E-13 SPECIAL COLLECTIONS AND ANALYSES Airborne Filters Liquid Subsoil Water Miscellaneous Water Samples 4 per month 1 per quarter 1 per month 4 per quarter 4-5 per year Sr-89, Sr-90 Sr-89, Sr-90 (comp.)

GA, Sr-89, Sr-90 GA, GB, H-3, GS Sr-89, Sr-90

" Locations codes are defined in Table 2. Control Stations are indicated by (C). All other stations are indicators.

b Analysis type is coded as follows: GB = gross beta, GA = gross alpha, GS = gamma spectroscopy, H-3 = tritium, Sr-89 = strontium-89, Sr-90 = strontium-90, 1-131 = iodine-131. Analysis frequency is coded as follows:

MC = monthly composite, QC = quarterly composite.

C-2

POINT BEACH NUCLEAR PLANT APPENDIX D Graphs of Data Trends D-1

POINT BEACH Air Particulates - Gross Beta Location E-1, monthly averages 2005-2009 0.050 -i 0.040 -.

0.030-/

j

  • o A

coS 0.020-I 0.010 -.

0.000)1 i 4 -t-i -- 4 ý ýi

ý,

-4+ --

-4ýf 2005 2006 2007 2008 2009 2010 Year Location E-2, monthly averages 2005-2009 0.050O E

CL 0*

0.040 0.030 0.020 4 0.010-2005 2006 2007 2008 2009 2010 Year D-2

POINT BEACH Air Particulates - Gross Beta Location E-3, monthly averages 2005-2009 0.050 0.040 0.030 0030 O-0.020 0.010

- - i 0.000 "

1-.

4-..-

-- HA--H i

t--"-, --, -+

t4-.- H-++-.

,-.-t 2005 2006 2007 2008 2009 2010 Year 0.050 -. Location E-4, monthly averages 2005-2009 0.040-0.030]

ca-0.020 I

0.010 2005 2006 2007 2008 2009 2010 Year D-3

POINT BEACH NUCLEAR PLANT APPENDIX E Supplemental Analyses E-1

POINT BEACH NUCLEAR PLANT Supplemental Analyses Location Collection Date 3-3 GW-09 1Z-361Ab 01-11-08 07-11-08 GW-Special 09-03-08 GW-09 1Z-361A 12-13-07 GW-09 1Z-361A 04-19-08 Lab Code EW-183 EWW-4116 EWW-4892 EWW-6390 EWW-6392 H-3 Fe-55 Sr-89 Sr-90 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Other Gammasa

-0.06 +/- 0.43 0.5 +/- 0.9 0.0 +/- 0.3 0.6 +/- 1.4 0.3 +/- 2.4 0.2 +/- 1.2

-0.1 +/-1.3 1.1 +/-2.7

-1.3 +/-1.5 1.2 +/-1.0

-0.3 +/-1.2

-4.6 +/-2.0 0.2 +/-1.3 1066 +/- 118 42 +/-+415 0.4 +/- 3.9

-20.8 +/- 15.7

-0.3 +/- 2.0 2.7 +/- 3.7

-0.7 +/-1.9 3.0 +/- 2.0 1.5 +/- 3.9

-5.8 +/- 2.1

-0.5 + 2.1

-0.1 +/-2.2

-5.5 + 6.6

.-0.5 +/- 1.7 23 +/- 74 1647.1 +/- 22.8 5.2 +/- 3.4

-113.2 +/- 6.2 51.5 +/- 3.3 2.8 +/- 3.5 5.4 +/- 8.3

-2519.9 +/- 3.1 4.4 +/- 3.4 2.1 +/- 3.3

>12 halflives

-276.6 +/- 3.0 222.4 +/- 20.0 1.0 +/-2.4

-17.1 +/-4.5

-11.3 +/- 2.3 2.9 +/- 2.7

-6.6 +/- 5.1

-37.7 +/- 2.4 2.0 +/- 2.1

-2.2 +/- 2.3

>12 halflives 3.5 +/-2.0 a RU-103 b From report 8006-100-830.

E-2

APPENDIX F DUPLICATE ANALYSES F-I

F-1. Airborne particulate filters, duplicate analyses for gross beta.

Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Location Collected (m3)

Gross Beta E-04 01-16-08 339 0.031 +/- 0.004 E-08 01-31-08 356 0.041 +/- 0.004 E-02 02-07-08 304 0.023 +/- 0.004 E-08 02-28-08 355 0.025 +/- 0.003 E-03 04-10-08 306 0.020 +/- 0.003 E-03 04-17-08 300 0.012 +/- 0.003 E-20 04-23-08 260 0.023 + 0.004 E-08 05-01-08 358 0.019 +/- 0.003 E-08 05-29-08 357 0.011 + 0.003 E-01 07-09-08 335 0.014 _ 0.003 E-08 07-23-08 307 0.022 + 0.003 E-03 08-06-08 303 0.017 + 0.003 E-04 08-25-08 184 0.026 +/- 0.005 E-08 10-15-08 261 0.030 +/- 0.004 E-0 1 10-29-08 253 0.021 +/- 0.004 E-04 11-06-08 380 0.038 +/- 0.003 E-01 12-03-08 294 0.030 +/- 0.004 E-08 12-10-08 306 0.026 +/- 0.003 E-08 12-30-08 302 0.055 +/- 0.004 F-2

F -2. Lake Water, duplicate analyses for gross beta, iodine-131 andgamma isotopic.

Units: pCi/L Location Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-i 34 Cs-137 Ba-La-140 Ru-103 Collections: Monthly E-06 ELW-191 01-16-08 1.6 +/- 1.0 0.13 +/- 0.22 E-01 E-01 1.3 1.1

-0.6

-1.1

-2.7 3.7 1.7

-1.2 0.8

-1.5 2.2

+ 2.1

+/- 2.3

+ 4.7

+2.1

+ 2.8

+ 6.5

+ 2.9

+/- 2.7

+ 2.7

+/- 4.4

+ 2.5 ELW-191 03-13-08 1.1 +/-0.9 0.02 +/- 0.16 4.0 +/- 12.6

-0.2 +/- 1.7

-1.2 +/-2.6 0.6 +/-1.3

-1,9 +/-1.6 0.8 +/-3.0 1.9 +/-1.7

-0.3 +/-1.4 0.8 +/-1.4 1.1 +/-1.5 0.0 +/-1.4 ELW-2940 06-12-08 1.7 +/- 0.6

-0.06 +/- 0.24 6.1 +/- 17.1

-0.9 +/- 2.0 0.5 +/- 3.8 0.3 +/-1.7 1.5 +/-1.9 0.3 +/-3.8

-1.1 +/-1.8

-0.5 +/-2.2 1.3 +/-1.9

-0.4 +/-1.9 0.8 +/-2.2 F -3. Lake Water, duplicate analyses for tritium, strontium-89 and strontium-90.

Location E-33 Lab Code Collection Period H-3 Sr-89 Sr-90 ELW-7308 4th Quarter

-32 +/- 68 0.23 +/- 0.75 0.14 +/- 0.29 F-3

F-4. Milk, duplicate analyses for 1-131, Sr-89190 and gamma isotopic.

Units: pCi/L Collection: Monthly Location E-21 E-40 Lab Code EMI-1007 EMI-6459 Date Collected 03-12-08 11-12-08 Sr-89

-0.8 +/- 1.0

-0.2 +/- 0.9 Sr-90 1.0 +/- 0.4 0.6 +/- 0.3 1-131 0.04 +/- 0.21 0.02 +/- 0.26 K-40 1410 +/- 111 1362 +/- 118 Cs-134 0.2 +/- 1.5 0.2 +/- 2.1 Cs-137 1.4 +/- 1.9

-0.5 +/- 2.2 Ba-La-140

-2.2 +/- 1.6

-2.4 +/- 2.1 Co-60 0.4 +/- 2.2

-0.5 +/- 2.5 F-4

F-5. Surface Water/Well Water, duplicate analyses for tritium.

Units: pCiIL Collections: Monthly, quarterly, quarterly composites Location Collection Date Lab Code GW-03 03-27-08 EWW-1267 S-03 04-02-08 EWW-1 596 335 +/- 94 H-3 99 +/- 94 Location Collection Date Lab Code H-3 GW-16 05-29-08 EWW-2645 277 +/- 85 GW-2 10-30-08 EWW-6225 178 +/- 85 Fagade Subsoil Sump 05-31-08 EW-2985 472 +/- 104 GW-16 10-22-08 EWW-6037 127 +/- 86 GW-02 05-30-08 EWW-2620 97

+/- 77 GW-16 06-24-08 EWW-3146 289 +/- 98 GW-06 10-15-08 EWW-5681

-23 +/- 84 Location Collection Date Lab Code H-3 F-5

F.6 Sediment, duplicate analyses for gross beta and gamma isotopic Units: pCi/g dry Collection: Semiannual Location Collection Date Lab Code Gross Beta 48 04-11-08 ESS-1660 17.28 +/- 2.15 Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 0.057 7.85 0.049 0.046 0.09 0.09 0.27 0.14

+ 0.072

+ 0.68

+/- 0.024

+ 0.017

+/- 0.024

+/- 0.030

+/- 0.17

+/- 0.075 F.7 Grass, duplicate analyses for gross beta and gamma isotopic Units: pCilg dry Collection: Semiannual Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Co-60 E-08 7/30/2008 EG-3935 2.17 9.17 +/- 0.34 1.41 +/-

5.98 +/-

-0.010 +/-

-0.004 +/-

0.005 +/-

0.001 +/-

0.27 0.57 0.015 0.013 0.013 0.012 F-6

POINT BEACH NUCLEAR PLANT APPENDIX G Special Reports G-1

Environmental, Inc.

SMidwest Laboratory S

an Allegheny Technologies Co.

700 Landwehr Road

  • Northbrook. L 60062-2310 ph. (847) 564-0700 - fax (847) 564-4517 Dr. Kjell Johansen FPL Energy LABORATORY REPORT NO.:

8006-100-826 Point Beach Nuclear Plant DATE:

06-26-2008 6610 Nuclear Road SAMPLES RECEIVED:

03-11-2008 Two Rivers, Wisconsin 54241 PURCHASE ORDER NO.:

Below are the results of the analyses for tritium in three water samples.

Sample Lab Concentration / LLD (DpCi/L)

Collection Description Code H-3 Date MH-06 EWW-890 31 +/- 97/ < 158 03-05-08 MH-07 EWW-891 242 +/- 105 / < 158 03-05-08 MH-08 EWW-892 139 +/- 101 / < 158 03-05-08 The error given is the probable counting error at the 95% confidence level. The less than (<) value, is based on 4.66 sigma counting error for the background sample.

Sincerely, Br

  1. ir bM.S.

Lab ory anager E-mail: KjeiLJohansen@fpl.com Hard copy included in the Monthly Report APPROVED BY

.Tony Coorlim, Quality Assurance

Environmental, Inc.

Midwest Laboratory an Allegheny Technologies Co.

700 Landwehr Road. Northbrook. IL 60062-2310 ph. (847) 564-0700 - fax (847) 564-4517 Dr. Kjell Johansen FPL Energy LABORATORY REPORT NO.:

8006-100-824 Point Beach Nuclear Plant DATE:

06-24-2008 6610 Nuclear Road SAMPLES RECEIVED:

06-09-2008 Two Rivers, Wisconsin 54241 PURCHASE ORDER NO.:

Below are the results of the analyses for tritium in five ground water samples.

Sample Lab Concentration / LLD (pCi/L)

Collection Description Code H-3 Date MH-67A EWW-2832 247 +/- 96 / < 172 06-02-08 MH-67B EWW-2833 309 +/- 99 / < 172 06-02-08 MH-67C EWW-2834 241 +/- 96 / < 172 06-02-08 MH-67D EWW-2835 155 +/- 92 1 < 172 06-02-08 MH-68 EWW-2836 223 +/- 95 / < 172 06-02-08 The error given is the probable counting error at the 95% confidence level. The less than (<) value, is based on 4.66 sigma counting error for the background sample.

ly, Bro ia S

E-mail: Kjell Johansen@fpl.com La toyage APPROVED BY Tony Coorlim, Quality Assurance

APPENDIX 2 UNIVERSITY OF WATERLOO (ONTARIO)

ENVIRONMENTAL ISOTOPE LABORATORY PRECIPITATION MONITORING RESULTS FOR THE POINT BEACH NUCLEAR PLANT REPORTING PERIOD: JANUARY - DECEMBER 2008

Client:

Johansen Point Beach Nuclear Plant ISO# 2008061 Location: T - 1 1 for 3H Environmental Isotope Lab 2008-02-27 1 of 1

  1. Sample 1 E-02 (SBCC Rain Water) 01/23/08 Lab#

3H Result +/- l Repeat +

171246 X 19.2 8.0 1 CY1

ý04 TR):

'1RTWI /4UOuT 22,1 P C To Contact ElL:

mepatton@uwaterloo.ca or phone:

519 888 4732 Robert J. Drimmie Laboratory Manager rdrimmie@uwaterloo.ca 519 888 4567 ext 32580

Client: Johansen FPL Energy Point Beach, LLC ISO# 2008261 Location: T-3 3 for 3H Environmental Isotope Lab 3/28/2009 1 of 1

  1. Sample Lab#

3H Result +/- ly Repeat +/- la 1 E-02 4-3-08 179606 X 29.1 8.0 2 E-03 4-3-08 179607 X 16.6 8.0 3 E-04 4-3-08 179608 X 19.2! 8.0 21.8 8.0 GI' Tritium is reported in Tritium Units.

1TU = 3.221 Picocurries/L per IAEA, 2000 Report.

1TU = 0.11919 Becquerels/L per IAEA, 2000 Report.

Robert J. Drimmie uwEILAB Manager rdrimmie@uwaterloo.ca 519 888 4567 ext 32580 To Contact uwEILAB:

519 888 4732

Client: Johansen FPL Energy - Point Beach Nuclear Plant ISO# 2008348 Location: T -

3 for 3H Environmental Isotope Lab 2008-06-12 1 of 1 Project # 8006

  1. Sample Lab#

3H Result +/- l0 Repeat + la 1 E-02 (SBCC Rain Water)

$'/'

181622 X 23.6 8.0 2 E-03 (Tapawingo Rd West of Lakeshore Rd) 181623 X 15.6 8.0 3!E-04 (North Boundary) 181624 X 20.8 8.0

&-7 Tritium is reported in Tritium Units.

ITU = 3.221 Picocurries/L per IAEA, 2000 Report.

1TU = 0.1.1919 Becquerels/L per IAEA, 2000 Report.

Robert J. Drimmie uwEILAB Manager rdrimmie@uwaterloo.ca 519 888 4567 ext 32580 To Contact uwEILAB:

519 888 4732

Client: Johansen FPL Energy Point Beach Nuclear Plant Project# 8006 ISO# 2008656 Location: T-7 3 for 3H Environmental Isotope Lab 3/28/2009 1 of 1

  1. Sample Lab#

3H Result +/- lo Repeat + lo 1 E-02 (SBCC Rain Water) 09/10/08 191771 X 13.7 8.0 2 E-03 (Tapawingo Rd West of Lakeshore Rd) 09/10/08 191772 X 9.7 8.0 3 E-04 (North Boundary 09/10/08 191773 X 12.4 8.0 16.6 8.0 pl'.

oSI -

Tritium is reported in Tritium Units.

1TU = 3.221 Picocurries/L per IAEA, 2000 Report.

ITU = 0.11919 Becquerels/L per IAEA, 2000 Report.

Robert J. Drimmie uwEILAB Manager rdrimmie@uwaterloo.ca 519 888 4567 ext 32580 To Contact uwEILAB:

519 888 4732

Client: Johansen FPL Energy Point Beach Nuclear Plant NPL 2008-0274 Project # 8006 ISO# 2008738 Location: T - 1 3 for 3H

  1. Sample Lab#

3H Result +/- la Repeat + la 1 E-02 0627 10/09/08 193702 X 16.1 8.0 2 E-03 0928 10/09/08 193703 X 21.3 8.0 3 E-04 0913 10/09/08 1193704 X 18.9 8.0 21.0 8.0 Environmental Isotope Lab 3/13/2009 1 of 1 6(2 Tritium is reported in Tritium Units.

1TU = 3.221 Picocurries/L per IAEA, 2000 Report.

1TU = 0.11919 Becquerels/L per IAEA, 2000 Report.

06r Robert J. Drimmie uwEILAB Manager To Contact uwEILAB:

rdrimmie@uwaterloo.ca 519 888 4732 519 888 4567 ext 32580

Client: Johansen FPL Energy Point Beach Nuclear Plant Contract #15872 Project #: 8006 ISO# 2008803 Location: T - 8 3 for 3H Environmental Isotope Lab 1/16/2009 1 of 1

  1. Sample Lab#

3H Result +/- la Repeat +lcy i E-02 11-06-08 195573 X

<6 8.0

<6 8.0 2 E-03 11-06-08 195574 X 10.6 8.0 3 E-04 11-06-08 195575 X 10.5 8.0

_,c 0/f

_- II Tritium is reported in Tritium Units.

1TU = 3.221 Picocurries/L per IAEA, 2000 Report.

1TU = 0.11919 Becquerels/L per IAEA, 2000 Report.

Robert J. Drimmie uwEILAB Manager rdrimmie@uwaterloo.ca 519 888 4567 ext 32580 To Contact uwEILAB:

519 888 4732

Client: Johansen FPL Energy Point Beach Nuclear Plant Contract #15872 ISO# 2008883 Location: T -

3 for 3H Environmental Isotope Lab 3/28/2009 1 of 2

  1. Sample Lab#

3H Result +/- la Repeat + la 1 E-02 (SBCC Rain Water) 12/03/08 198071 X 20.6 8.0 2 E-03 (Tapawingo Rd West of Lakeshore Rd) 12/03/08 198072 X 113.0 8.0 16.9 8.0 3 E-04 (North Boundary) 12/03/08 198073 X

<6, 8.0

<6 8.0

  • This sample bottle arrived broken - water sample froze and we saved portion in jar.

Sample to be run. See what result we get.

Tritium is reported in Tritium Units.

1TU = 3.221 Picocurries/L per IAEA, 2000 Report.

1TU = 0.11919 Becquerels/L per IAEA, 2000. Report.

64 L1~

Robert J. Drimmie uwEILAB Manager rdrimmie@uwaterloo.ca 519 888 4567 ext 32580 To Contact uwEILAB:

519 888 4732