Category:License-Monthly Operating Report
MONTHYEARNRC 2005-0080, February 2005 Monthly Operating Report for Point Beach Nuclear Plant, Unit 1 & 22005-08-19019 August 2005 February 2005 Monthly Operating Report for Point Beach Nuclear Plant, Unit 1 & 2 NRC 2005-0034, February 2005 Monthly Operating Report for Point Beach Units 1 & 22005-03-14014 March 2005 February 2005 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2005-0025, January 2005 Monthly Operating Report for Point Beach Nuclear Plant, Units I and 22005-02-10010 February 2005 January 2005 Monthly Operating Report for Point Beach Nuclear Plant, Units I and 2 NRC 2005-0011, December 2004 Monthly Operating Report for Point Beach, Units 1 & 22005-01-13013 January 2005 December 2004 Monthly Operating Report for Point Beach, Units 1 & 2 NRC 2004-0136, November 2004 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 and 22004-12-13013 December 2004 November 2004 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 and 2 NRC 2004-0118, October 2004 Monthly Operating Report for Point Beach, Units 1 and 22004-11-0808 November 2004 October 2004 Monthly Operating Report for Point Beach, Units 1 and 2 NRC 2004-0105, September 2004 Monthly Operating Report for Point Beach Units 1 and 22004-10-12012 October 2004 September 2004 Monthly Operating Report for Point Beach Units 1 and 2 NRC 2004-0095, August 2004 Monthly Operating Report for Point Beach Nuclear Plant Units 1 and 22004-09-15015 September 2004 August 2004 Monthly Operating Report for Point Beach Nuclear Plant Units 1 and 2 NRC 2004-0080, July 2004 Monthly Operating Report for Point Beach Units 1 and 22004-08-12012 August 2004 July 2004 Monthly Operating Report for Point Beach Units 1 and 2 NRC 2004-0074, June 2004 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 & 22004-07-14014 July 2004 June 2004 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 & 2 NRC 2004-0061, April 2004 Revised Monthly Operating Report for Point Beach, Units 1 and 22004-06-0404 June 2004 April 2004 Revised Monthly Operating Report for Point Beach, Units 1 and 2 NRC 2004-0049, April 2004 Monthly Operating Report Regarding Point Beach Nuclear Plant Units 1 and 22004-05-11011 May 2004 April 2004 Monthly Operating Report Regarding Point Beach Nuclear Plant Units 1 and 2 NRC 2004-0037, March 2004 Monthly Operating Report for Point Beach Units 1 & 22004-04-12012 April 2004 March 2004 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2004-0027, February 2004 Monthly Operating for Point Beach Units 1 and 22004-03-12012 March 2004 February 2004 Monthly Operating for Point Beach Units 1 and 2 NRC 2004-0018, January 2004 Monthly Operating Report for Point Beach, Units 1 and 22004-02-12012 February 2004 January 2004 Monthly Operating Report for Point Beach, Units 1 and 2 NRC 2004-0003, December 2003 Monthly Operating Report for Point Beach, Units 1 and 22004-01-12012 January 2004 December 2003 Monthly Operating Report for Point Beach, Units 1 and 2 NRC 2003-0117, November 2003 Monthly Operating Report for Point Beach, Units 1 and 22003-12-11011 December 2003 November 2003 Monthly Operating Report for Point Beach, Units 1 and 2 NRC 2003-0109, September 2003 Monthly Operating Report for Point Beach Nuclear Plant2003-11-11011 November 2003 September 2003 Monthly Operating Report for Point Beach Nuclear Plant NRC 2003-0093, September 2003 Monthly Operating Report for Point Beach2003-10-13013 October 2003 September 2003 Monthly Operating Report for Point Beach NRC 2003-0082, August 2003 Monthly Operating Report for Point Beach Units 1 and 22003-09-11011 September 2003 August 2003 Monthly Operating Report for Point Beach Units 1 and 2 NRC 2003-0061, June 2003 Monthly Operating Report for Point Beach Units 1 & 22003-07-11011 July 2003 June 2003 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2003-0054, May 2003 Monthly Operating Report for Point Beach Units 1 and 22003-06-0909 June 2003 May 2003 Monthly Operating Report for Point Beach Units 1 and 2 NRC 2003-0041, April 2003 Monthly Operating Report for Point Beach Units 1 & 22003-05-12012 May 2003 April 2003 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2003-0032, March 2003 Monthly Operating Report for Point Beach, Units 1 & 22003-04-0707 April 2003 March 2003 Monthly Operating Report for Point Beach, Units 1 & 2 NRC 2003-0022, February 2003 Monthly Operating Report for Point Beach, Units 1 and 22003-03-0606 March 2003 February 2003 Monthly Operating Report for Point Beach, Units 1 and 2 NRC 2003-0013, January 2003 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 & 22003-02-11011 February 2003 January 2003 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 & 2 NRC 2003-0003, December 2002 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 & 22003-01-0606 January 2003 December 2002 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 & 2 NRC 2002-0106, November 2002 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 & 22002-12-10010 December 2002 November 2002 Monthly Operating Report for Point Beach Nuclear Plant, Units 1 & 2 NRC 2002-0100, October 2002 Monthly Operating Report for Point Beach Units 1 & 22002-11-15015 November 2002 October 2002 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2002-0088, September 2002 Monthly Operating Report for Point Beach Units 1 & 22002-10-0202 October 2002 September 2002 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2002-0078, August 2002 Monthly Operating Report for Point Beach Units 1 & 22002-09-0909 September 2002 August 2002 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2002-0066, July 2002 Monthly Operating Report for Point Beach Units 1 & 22002-08-12012 August 2002 July 2002 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2002-0058, June 2002 Monthly Operating Report for Point Beach Units 1 & 22002-07-0909 July 2002 June 2002 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2002-0049, May 2002 Monthly Operating Report for Point Beach Units 1 & 22002-06-0505 June 2002 May 2002 Monthly Operating Report for Point Beach Units 1 & 2 NRC 2002-0034, April 2002 Monthly Operating Report for Point Beach, Units 1 & 22002-05-0303 May 2002 April 2002 Monthly Operating Report for Point Beach, Units 1 & 2 NRC 2002-0025, March 2002 Monthly Operating Report for Point Beach Nuclear Plant Units 1 & 22002-04-15015 April 2002 March 2002 Monthly Operating Report for Point Beach Nuclear Plant Units 1 & 2 NRC 2002-0021, February 2002 Monthly Operating Report for Point Beach, Units 1 & 22002-03-15015 March 2002 February 2002 Monthly Operating Report for Point Beach, Units 1 & 2 NRC 2002-0014, January 2002 Monthly Operating Report for Point Beach, Units 1 & 22002-02-15015 February 2002 January 2002 Monthly Operating Report for Point Beach, Units 1 & 2 NRC 2002-0003, December 2001 Monthly Operating Report for Point Beach Nuclear Plant Unit 1 and 22002-01-0707 January 2002 December 2001 Monthly Operating Report for Point Beach Nuclear Plant Unit 1 and 2 2005-08-19
[Table view] |
Text
Text
Kewaunee Nuclear Power Plant Point Beach Nuclear Plant N490 Highway 42 6610 Nuclear Road Kewaunee, WI 54216-9511 Two Rivers, WI 54241 920.388.2560 920.755.2321 Committed to Nuclear Excellen> Kewaunee / Point Beach Nuclear Operated by Nuclear Management Company, LLC NRC 2002-0034 GL 97-02 May 03, 2002 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Ladies/Gentlemen:
Dockets 50-266 And 50-301 Point Beach Nuclear Plant, Units 1 And 2 Monthly Operating Reports Attached are monthly operating reports for Units 1 and 2 of the Point Beach Nuclear Plant for the calendar month of April 2002.
Sincerely, T. J. Webb Regulatory Affairs Manager KML Attachment cc: J. D. Loock, PSCW NRC Region III NRC Senior Resident Inspector NRC Project Manager
--c"4
- Docket 50-266 and 50-301 NRC-2002-0034 ATTACHMENT 1 Letter from Thomas J. Webb (NMC)
To Document Control Desk (NRC)
Dated May 03, 2002 Re: Monthly Operating Report - April 2002
OPERATING DATA REPORT DOCKET NO. 50-266 DATE: 05/02/02 COMPLETED BY: Kim M. Locke TELEPHONE: 920-755-6,420 OPERATING STATUS
- 1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 1 NOTES
- 2. REPORTING PERIOD: April - 2002
- 3. LICENSED THERMAL POWER (MWT): 1,518.5
- 4. NAMEPLATING RATING (GROSS MWE): 537.7
- 5. DESIGN ELECTRICAL RATING (NET MWE): 515.0
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 530.0
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 510.0
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): n/a
- 10. REASONS FOR RESTRICTIONS, (IF ANY):
n/a THIS MONTH YEAR TO DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD 719.0 2,879.0 275,974.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL 719.0 2,879.0 226,488.8
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 667.3
- 14. HOURS GENERATOR ONLINE 719.0 2,879.0 222,973.0
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 846.9
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1,091,081.0 4,357,162.0 318,359,613.0
- 17. GROSS ELECTRICAL ENERGY GENERATED 379,740.0 1,514,260.0 108,056,360.0
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 363,661.0 1,451,271.5 103,026,791.5
- 19. UNIT SERVICE FACTOR 100.0% 100.0% 80.8%
- 20. UNIT AVAILABILITY FACTOR 100.0% 100.0% 81.1%
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 99.2% 98.8% 76.3%
- 22. UNIT CAPACITY FACTOR (USING DER NET) 98.2% 97.9% 74.8%
- 23. UNIT FORCED OUTAGE RATE 0.0% 0.0% 4.4%
DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED MAY 15, 1997
UNIT SHUTDOWNS DOCKET NO. 50-266 UNIT NAME: Point Beach, Unit 1 DATE: 05/02/02 COMPLETED BY: Kim M. Locke TELEPHONE: 755-6420 REPORTING PERIOD: April 2002 (Month/Year)
NO. DATE TYPE DURATION REASON (1) METHOD OF CAUSE/CORRECTIVE ACTIONS F: FORCED (HOURS) SHUTTING S: SCHEDULED DOWN (2) COMMENTS N/A N/A N/A N/A N/A N/A N/A (1) Reason (2) Method A. Equipment Failure (Explain) 1 Manual B. Maintenance or Test 2 Manual Trip/Scram C. Refueling 3 Automatic Trip/Scram D. Regulatory Restriction 4. Continuation E. Operator Training/license Examination F .Administrative 5. Other (Explain)
G .Operational Error (Explain) H .Other (Explain)
SUMMARY
Unit 1 average daily power for the month of March was 500.4 MWe.
There were no Licensee Event Reports (LERs) submitted to the NRC.
There were no Significant Operating Events.
OPERATING DATA REPORT DOCKET NO. 50-301 DATE: 05/02/02 COMPLETED BY: Kim M. Locke TELEPHONE: 920-755-6,420 OPERATING STATUS
- 1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 2 NOTES
- 2. REPORTING PERIOD: April - 2002
- 3. LICENSED THERMAL POWER (MWT): 1,518.5
- 4. NAMEPLATING RATING (GROSS MWE): 537.7
- 5. DESIGN ELECTRICAL RATING (NET MWE): 515.0
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 532.0
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 512.0
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): n/a
- 10. REASONS FOR RESTRICTIONS, (IF ANY):
n/a THIS MONTH YEAR TO DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD 719.0 2,879.0 260,759.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL 286.6 2,385.9 220,167.5
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 233.9
- 14. HOURS GENERATOR ONLINE 284.4 2,372.7 217,226.9
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 302.2
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 424,563.0 3,539,519.0 313,587,936.0
- 17. GROSS ELECTRICAL ENERGY GENERATED 149,230.0 1,236,500.0 106,964,540.0
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 141,924.0 1,183,401.5 101,966,908.5
- 19. UNIT SERVICE FACTOR 39.6% 82.4% 83.3%
- 20. UNIT AVAILABILITY FACTOR 39.6% 82.4% 83.4%
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 38.6% 80.3% 79.7%
- 22. UNIT CAPACITY FACTOR (USING DER NET) 38.3% 79.8% 78.4%
- 23. UNIT FORCED OUTAGE RATE 0.0% 2.9% 2.2%
DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETIER DATED MAY 15, 1997
UNIT SHUTDOWNS DOCKET NO. 50-301 UNIT NAME: Point Beach, Unit 2 DATE: 05/02/02 COMPLETED BY: Kim M. Locke TELEPHONE: 755-6420 REPORTING PERIOD: April 2002 (Month/Year)
NO. DATE TYPE DURATION REASON (1) METHOD OF CAUSE/CORRECTIVE ACTIONS F: FORCED (HOURS) SHUTTING S: SCHEDULED DOWN (2) COMMENTS 3 04/12/02 S 432.4 C 1 (1) Reason (2) Method A. Equipment Failure (Explain) 1 Manual B. Maintenance or Test 2 Manual Trip/Scram C. Refueling 3 Automatic Trip/Scram D. Regulatory Restriction 4. Continuation E. Operator Training/license Examination F .Administrative 5. Other (Explain)
G .Operational Error (Explain) H .Other (Explain)
SUMMARY
Unit 2 average daily power for the month of March was 197.8 MWe.
Licensee Event Report (LER) 301/2002-001-00, Completion Of Nuclear Plant Shutdown Required By LCO 3.5.2 Required Action B.1, was submitted to the NRC for the Unit 2 shutdown on Feb. 22, 2002.
There were no Significant Operating Events.