NMP1L3380, Special Report: Containment High Range Radiation Monitor Instrumentation Channel 11 Inoperable

From kanterella
Jump to navigation Jump to search
Special Report: Containment High Range Radiation Monitor Instrumentation Channel 11 Inoperable
ML21078A102
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 03/17/2021
From: Schuerman A
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NMP1L3380
Download: ML21078A102 (2)


Text

  • /

~;./ Exelon Generation Technical Specifications NMP1L3380 March 17, 2021 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Nine Mile Point Nuclear Station, Unit 1 Renewed Facility Operating License No. DPR-63 Docket No. 50-220

Subject:

Special Report: Containment High Range Radiation Monitor.Instrumentation Channel #11 Inoperable In accordance with Action 3 of Nine Mile Point Unit 1 (NMP1) Technical Specification (TS)

Table 3.6.11-2, "Accident Monitoring Instrumentation Action Statements," Nine Mile Point Nuclear Station, LLC (NMPNS) is submitting the following Special Report concerning inoperability of Containment High Range Radiation Monitor Instrumentation Channel #11.

Description of Event On March 12, 2021 at 0850, the Channel #11 Containment High Range Radiation Monitor was declared inoperable for performance of planned preventive maintenance to replace aged components within the Readout Module in accordance with station workorder C93697385.

The redundant channel of Containment High Range Radiation Monitor Instrumentation, Channel #12, was operable during the period Channel #11 was inoperable.

Cause of lnoperability The cause of the inoperability was to perform planned preventive maintenance.

Action Taken Instrument maintenance technicians completed the planned preventive maintenance and the Containment High Range Radiation Monitor Instrumentation Channel #11 was restored to operable on March 12, 2021 at 1403.

NMP1 Special Report March 17, 2021 Page 2 Should you have any questions regarding the information in this submittal, please contact Brandon Shultz, Mgr. Site Regulatory Assurance, at (315) 349-7012.

Sincerely,

{; Digitally signed by Schuerman, Schuerman, I\AdamG

/)'.lN:ccn=Schuerman, Adam G AdamG t.>/ . Dat;: 2021.03.15 06:51 :08 -04'00' Adam G. Schuerman Pl~nt Manager, Nine Mile Point Nuclear Station Exelon Generation Company, LLC AGS/BKS cc: NRC Regional Administrator, Region I NRC Senior Resident Inspector NRC Project Manager