P.O. Box 63 Lycoming, New York 13093 Constellation Nuclear Nine Mile Point Nuclear Station January 21, 2002 A Member of the NMPIL 1638 Constellation Energy Group U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 RE:

Nine Mile Point Unit 1 Docket No. 50-220 DPR-63 Subiect:

Special Report, Channel #11 Containment Hydrogen Monitoring System Inoperable for Scheduled Elective Maintenance Gentlemen:

In accordance with Action Statement 4.a of Nine Mile Point Unit 1 Technical Specification Table 3.6.11-2, "Accident Monitoring Instrumentation Action Statements,"

Nine Mile Point Nuclear Station, LLC is submitting the following Special Report concerning the inoperability of Channel #11 Containment Hydrogen Monitoring System.

Description of Event On January 8, 2002, at approximately 1230 hours0.0142 days <br />0.342 hours <br />0.00203 weeks <br />4.68015e-4 months <br />, operators declared Channel #11 Containment Hydrogen Monitoring System inoperable in order to perform scheduled elective maintenance. The scheduled maintenance was to replace components in both the hydrogen analyzer and oxygen analyzer. The maintenance was completed on January 9, 2002 and the system returned to service at approximately 1720 hours0.0199 days <br />0.478 hours <br />0.00284 weeks <br />6.5446e-4 months <br />.

The redundant Channel #12 Containment Hydrogen Monitoring System was verified in service prior to removing Channel #11 from service.

Cause of Event The Channel #11 Containment Hydrogen Monitoring System was declared inoperable in order to perform scheduled elective maintenance.

Page 2 NMP1L 1638 Corrective Actions The maintenance was completed and Channel #11 Containment Hydrogen Monitoring System was returned to an operable status.

Very truly yours, Lawrence A. Hopkins Unit 1 Plant General Manager LAH/KLE/cld xc: