Southern Nuclear Operating Company, Inc.

Post Off ice Box 1295 Birmingham, Alabama 35201-1295 Tel 205.992.5000 January 22, 2007 Energy to Serve b u r WorldSY Docket Nos.: 50-424 50-425 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Vogtle Electric Generating Plant Inservice Inspection Summary Report Ladies and Gentlemen:

Southern Nuclear Operating Company (SNC) submits herewith the Vogtle Electric Generating Plant Unit 1, Interval 2, Period 3, Outage 2 Inservice Inspection Summary Report (Enclosure). This report describes and summarizes the inservice inspection activities performed during the fall 2006 maintenancelrefuelingoutage. Paragraph IWA-6230 of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, 1989 Edition requires submittal of the enclosed report.

The supporting inservice inspection documentation, e.g., examination plans and schedules, examination results and reports, examination methods and procedures, evaluation results, and corrective action and repairs, is available for review upon request at Vogtle Electric Generating Plant.

This letter contains no NRC commitments. If you have any questions, please advise.

Sincerely, T. E. Tynan Vice President - Vogtle Vogtle Electric Generating Plant 7821 River Road Waynesboro, GA 30830

Enclosure:

Vogtle Electric Generating Plant - Unit 1 Inservice Inspection Summary Report Refueling Outage (1R 13)

U. S. Nuclear Regulatory Commission NL-07-0 122 Page 2 cc: Southern Nuclear Operating Comvany Mr. J. T. Gasser, Executive Vice President RType: CVC7000 U. S. Nuclear Regulatorv Commission Dr. W. D. Travers, Regional Administrator Mr. R. E. Martin, NRR Project Manager - Vogtle Mr. G. J. McCoy, Senior Resident Inspector - Vogtle

Enclosure Vogtle Electric Generating Plant Unit 1 Inservice Inspection Summary Report Refueling Outage (1R13)

OWNER'S REPORT FOR INSERVICE INSPECTIONS for the THIRTEENTH MAINTENANCEIREFUELING OUTAGE VOGTLE ELECTRIC GENERATING PLANT, UNIT 1 (7821 River Road, P. 0. Box 1600, Waynesboro, Georgia 30830)

COMMERCIAL OPERATION DATE: May 31,1987 DOCUMENT COMPLETION DATE: January 2007 Prepared by SOUTHERN NUCLEAR OPERATING COMPANY (40 Inverness Center Parkway, P. 0. Box 1295, Birmingham, Alabama 35201) as LICENSEE AND OPERATING AGENT for GEORGIA POWER COMPANY (241 Ralph McGill Boulevard, N.E., P. 0. Box 4545, Atlanta, Georgia 30308-3374) as OWNER

Introduction ASME Form NIS-1 with Abstract - ASME Class 1 and 2 Class CC Containment Examinations and Tests (IWL)

Examination Summary Listings Class 1 and 2 Weld and Support Examinations System Pressure Tests Reportable Indication Summary Owner's Reports for Repairs or Replacements (Form NIS-2)

LIST OF ABBREVIATIONS ACC Acceptable AD AnchorDarling AFW Auxiliary Feedwater System A1 GPC Action Item (followed by unique no. denoting Action Item number)

AN11 Authorized Nuclear Inservice Inspector ASME American Society of Mechanical Engineers ASNT American Society for Nondestructive Testing ASTM American Society for Testing and Materials BC Branch Connection ccss Centrifugally Cast Stainless Steel CCW Component Cooling Water CE Combustion Engineering CH Closure Head CR Condition Report CS Containment Spray cvcs Chemical and Volume Control System DS Downstream ET Eddy Current Examination EVAL Evaluation FAC Flow-Accelerated Corrosion (may also be referred to as "erosion/corrosion")

FB Flange Bolting FNF FAC Notification Report FW Feedwater System FSAR VEGP Final Safety Analysis Report (includes updates thereto)

GEO Geometric Indications GPC Georgia Power Company HHSI High Head Safety Injection HL Hanger Lug HX Heat Exchanger HYD Hydraulic Snubber IEN NRC Information Notice (may also be shown as "IN" followed by unique no. denoting notice number)

IND Indication INF Indication Notification Form IS1 Inservice Inspection IST Inservice Testing ITS VEGP Improved Technical Specification ID Inside Diameter IR Inside Radius LB Large Bore LD Longitudinal Seam Weld Extending Downstream LD-I Longitudinal Seam Weld Downstream Inside Radius of Elbow LD-0 Longitudinal Seam Weld Downstream Outside Radius of Elbow LMT Lambert, MacGill and Thomas LU Longitudinal Seam Weld Extending Upstream LU-I Longitudinal Seam Weld Upstream Inside Radius of Elbow LU-0 Longitudinal Seam Weld Upstream Outside Radius of Elbow MECH Mechanical Snubber MS Main Steam System MT Magnetic Particle Examination NCI Nonconformance Item NDE Nondestructive Examination

LIST OF ABBREVIATIONS (continued) -

NI No Indication NRC United States Nuclear Regulatory Commission NRC-B NRC Bulletin (followed by unique no. denoting Bulletin number)

NRI No Recordable Indication NSCW Nuclear Service Cooling Water System OR Outside Radius PL Pipe Lug PM Paul-Munroe ENERTECH PR Pipe Restraint PROF Profile PS Pipe Support PSA Pacific Scientific PSI Preservice Inspection PT Liquid Penetrant Examination RCS Reactor Coolant System RCP Reactor Coolant Pump RHR Residual Heat Removal System RI Recordable Indication RLW Refracted Longitudinal Wave RL Restraint Lug RPV Reactor Pressure Vessel RR Relief Request (followed by unique no. denoting relief request number)

RWST Refueling Water Storage Tank SAT Satisfactory Examination Results SB Small Bore SCS Southern Company Services SI Safety Injection System SNC Southern Nuclear Operating Company SUP Supplemental Data T&C Thickness and Contour TDAFW Turbine Driven Auxiliary Feedwater (Pump)

UNSAT Unsatisfactory Examination Results us Upstream UT Ultrasonic Examination VEGP Vogtle Electric Generating Plant (common unless followed by "-1" or "-2" to designate a specific plant unit)

Visual Examination Westinghouse iii

INTRODUCTION This report documents the examinations and tests performed at Vogtle Electric Generating Plant, Unit 1 (VEGP- I) between April 10,2005 (date of last examination performed during the twelfth maintenancelrefueling outage, 1R12) and October 27,2006 (date of last examination performed during the thirteenth maintenancetrefueling outage, 1R13) to meet the requirements of Article IWA-6000 of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, 1989 Edition (Code).

This report also addresses Code-applicable repairs andlor replacements, which were documented since the twelfth maintenancelrefueling outage at VEGP-I through the completion of the thirteenth maintenancelrefbeling outage in October 27,2006. The Owner's Reports for Repairs and Replacements (Form NIS-2) are included herein.

This report does not include a summary of the Steam Generator Tube Inspections which are required per VEGP Technical Specification 5.6.10. This will be provided in a separate report within one hundred eighty (1 80) days after the initial entry into MODE 4 following completion of an inspection performed in accordance with Technical Specification 5.5.9. The ASME Code requirements were met and the separate report will provide the details for these examinations.

FORM NIS-1 OWNER'S REPORT FOR MSERVICE INSPECTIONS As rewired bv the Provisions of the ASME Code Rules

1. Owner: Georgia Power Company, 241 Ralph McGill Blvd., N. E.

P. 0 . Box 4545, Atlanta, Georgia 30308-3374

2. Plant: Vogtle Electric Generating Plant, 7821 River Road P. 0. Box 1600, Waynesboro, Georgia 30830
3. Plant Unit: One
4. Owner Certification of Authorization: NIA
5. Commercial Service Date: 0513 1/87
6. National Board Number for Unit: NIA
7. Components Inspected:

Component or Manufacturer or Manufacturer or Installer State or Province National Board Appurtenance Installer and Serial Number Number Number Address Reactor Combustion Eng. 7372 N/A 22004 Pressure Vessel Inc.,

Chattanooga, TN Selected Piping, Pullman Power System Numbers 1201,1204, N/A NIA Components, Products, 1205,1208,1301,1302 &

and Supports Williamsport, PA 1305.

FORM NIS- 1 (Back)

8. Examination Dates: A ~ r i l10.2005 to October 27.2006
9. Inspection Period Identifiation: Third Period
10. Inspection Interval Identification: Second Ins~ectionInterval I I. Applicable Edition of Section XI =Addenda None
12. DatefRevision of Inspection Plan: Januaw 5.2007 / Revision 8
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. (See Abstract and Examination Summary Listings)
14. Abstract of Results of Examinations and Tests. (See Abstract)
15. Abstract of Corrective Measures. (See Abstract)

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) _N/A Expiration Date N/A Date: 1 7 d L . 2 0 ~Signed: Southern Nuclear Operating By:

Com~any.Inc. f p ~

Georgia Power Com~any Owner CERTIFICATE OF TNSERVICE TNSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Georgia and employed by The Hartford Steam Boiler hs~ectionand Insurance ComDanvof of Hartford. CT have inspected the components described in this Owner's Report during the period A ~ r i 10.2005 l to,- and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations, tests, and corrective measures described in this Owner's Report. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commission: 6 A ?C6 National Board, State, Province, and Endorsements Date: / k T-20s

ABSTRACT - ASME CLASS 1 AND 2 Introductionf tatus The ASME Boiler and Pressure Vessel Code,Section XI, 1989 Edition (Code), is the applicable code for conducting inservice inspection activities during the second ten-year inspection interval at VEGP-1. Examinations and tests required by the Code are scheduled in accordance with "Inspection Program B" as defined in Code paragraphs IWB-2412 and IWC-2412. This "Owner's Report for Inservice Inspection" is for those third inspection period examinations and tests which were performed between April 10,2005 (date of last examination performed during the twelfth maintenancelreheling outage, 1R12) and October 27,2006 (date of last examination performed during the thirteenth maintenancelrefueling outage, 1R13).

The Risk Informed Program was approved by the NRC by letter dated September 30,2003 and implemented during the VEGP 1R11 reheling outage (ASME Class 1 and Class 2 piping only).

By Federal Register Notice 64 FR 5 1370 dated September 22, 1999, 10CFR 50.55a(g)(6)(ii)(C), lmplementation of Appendix VIII to Section XI, was incorporated into the rule to expedite implementation of Appendix VIII. The specific Supplements of Appendix VIII to Section XI, ASME Boiler and Pressure Vessel Code, 1995 Edition with the 1996 Addenda were implemented prior to the 1R12 rnaintenancelrefueling outage as required.

In addition to the summary of inservice inspection activities, this report addresses Code-applicable repairs and replacements documented at VEGP-1 since 1R12 through the end of 1R13. Class 1 and Class 2 Owner's Reports for Repairs or Replacements (Form N1S-2) are provided herein.

It should be noted that Authorized Nuclear lnservice Inspector (ANII) inspection services were provided for those examinations and tests required by the Code. ASME Section XI examinations and tests are itemized in the applicable sections by reference to Examination Category. Examinations which do not meet the Code-required coverage either reference request(s) for relief or indicate that additional relief is required.

Selected Class 1 and 3 examinations were not performed during the 1R13 outage. These examinations have been deferred until the 1R14 outage or at some other time which satisfies the requirement to perform the Second IS1 interval examinations within the one-year extension past the end of the interval (May 30,2007). Since the 1R14 outage will be in Spring 2008, examinations performed during that outage will satisfy ASME Code requirements.

The required examinations for Class 2 components were satisfied.

Class 1 Examinations Selected Class 1 components were examined by Southern Nuclear Operating Company (SNC) personnel utilizing ultrasonic testing (UT), magnetic particle testing (MT), liquid penetrant (PT), and visual testing (VT) methods, as applicable. Specific components and examination areas are itemized in the applicable portions of this document.

During the scope of VEGP- I examinations conducted, no Class 1 components were observed to have reportable UT. PT or MT indications.

In addition to components already identified in current requests for relief, five (5) reactor pressure vessel welds had limited volumetric coverage during UT examinations because of physical limitations due to the geometric configuration of the welded areas. In addition, two (2) reactor pressure vessel integrally welded attachments had limited surface coverage because of physical limitations due to the geometric configuration of the welded areas.

More than ninety percent (90%) of the required volume must be examined as addressed in ASME Section XI Code Case N-460 for adequate ASME Section XI Code-required examination coverage to be attained. As noted herein, the subject code case has been approved by the NRC for use as documented in NRC Regulatory Guide 1.147. It is impractical to achieve the ASME Section XI Code-required coverage due to the geometric configuration of the welded areas. These limited examinations will be submitted to the NRC through the relief request process as allowed by 10 CFR 50.55a.

Class 1 Pressure Test Table IWB-2500-1, Examination Category B-P, of ASME Section XI requires the performance of a system leakage test (IWB-5221) each maintenance/refueling outage. This system leakage test (LT-1) was performed prior to plant startup following the refueling outage. These visual examinations revealed minor leakage and boron residue at mechanical connections. These leakage conditions were either corrected or evaluated and determined acceptable for continued system operation.

Table IWB-2500- 1, Examination Category B-P, of ASME Section XI also requires the performance of a system hydrostatic test (IWB-5222) once at or near the end of each inspection interval. This test is identified as the Class 1 hydrostatic test (HT-1) and it extends to the Class 1 pressure boundary extremity (i.e., second isolation valve) and also includes selected adjacent Class 2 components which are typically isolated from the Class 1 boundary by check valves. As an alternative to ASME Section XI requirements, Code Case N-498-4, which was conditionally accepted for use in Revision 14 of Regulatory Guide 1.I47 dated August 2005, was used. Code Case N-498-4 deleted the elevated pressure requirement for the hydrostatic test and reduced the holding time requirement but retained the requirement to extend the boundary subject to test pressurization to include each of the Class 1 pressure-retaining components. To assure that all Class 1 pressure retaining components and selected adjacent Class 2 pressure retaining components are pressurized requires for some isolated boundaries that valves be aligned to positions other than their normal alignment and for some isolated boundaries the use of a hydrostatic test pump. Portions of this test were not completed during the 1R13 maintenance / refueling outage nor are they planned to be completed by the end of the second inspection interval which ends May 30,2007. However, as allowed by IWB-2412 the remaining portions are scheduled to be performed in maintenance /refueling outage 1R14 which is scheduled in the Spring of 2008. The visual examinations performed in the 1R13 maintenance / refueling outage revealed minor leakage and boron residue at mechanical connections. These leakage conditions were either corrected or evaluated and determined acceptable for continued system operation.

ASME Section XI, Subparagraph IWA-5242(a) requires removal of insulation from pressure-retaining bolted connections for VT-2 examination during system pressure testing for systems borated for the purposes of controlling reactivity. ASME Section XI Code Cases N-533-1 and N-616 were utilized during the refueling outage. These Code Cases were approved for use in Revision 13 of Regulatory Guide 1.147 dated June 2003. Case N-533-1 allows insulation to be removed while the connections are at atmospheric or static pressures. With the insulation removed a direct visual examination is performed to detect previously occurring leakage through the presence of boric acid crystals. Case N-616 allows the VT-2 examination to occur without insulation removal provided the bolting material is resistant to boric acid degradation.

The test boundary of the system leakage test includes both Class 1 and Class 2 components. The frequency for removal of insulation and direct visual examination for Class 1 pressure-retaining bolted connections is once each refueling outage (refer to Table IWB-2500-1, Examination Category B-P) and as such those activities occurred during the refueling outage. The Class 2 components comprise part of the reactor coolant pressure boundary but are not required to be classified as Class 1 per 10 CFR 50.55a(c)(2). The frequency for removal of insulation and direct visual examination for Class 2 pressure-retaining bolted connections is once each inspection period (refer to Table IWC-2500-1, Examination Category C-H). Those applicable Class 2 activities were completed also during the refueling outage.

Class 2 Examinations Selected Class 2 Piping welds were examined utilizing UT. Specific components and examination areas are itemized in the applicable portions of this report document.

During the scope of VEGP-1 examinations conducted, no Class 2 components were observed to have reportable indications.

Two (2) piping weld examinations had limited coverage due to the geometric configuration of the welded areas.

More than ninety percent (90%) of the required volume must be examined as addressed in ASME Section XI Code Case N-460 for adequate ASME Section XI Code-required examination coverage to be attained. As noted herein, the subject code case has been approved by the NRC for use as documented in NRC Regulatory Guide 1.147. It is impractical to achieve the ASME Section XI Code-required coverage due to the geometric configuration of the welded areas. These limited examinations will be submitted to the NRC through the relief request process as allowed by 10 CFR 50.55a.

Class 2 Pressure Tests Table IWC-2500-1, Examination Category C-H, of ASME Section XI requires system pressure testing each inspection period. The specific system pressure tests performed are itemized in the "Pressure Tests" portion of this report document. The visual examinations performed during these system pressure tests found only minor leakage or residue at mechanical joints such as valve stem packing and at flanged connections. These leakage conditions were either corrected or evaluated and determined acceptable for continued system operation.

ASME Section XI, Subparagraph IWA-5242(a) requires removal of insulation from pressure-retaining bolted connections for VT-2 examination during system pressure testing for systems borated for the purposes of controlling reactivity. ASME Section XI Code Cases N-533-1 and N-616 were utilized. These Code Cases were approved for use in Revision 13 of Regulatory Guide 1.147 dated June 2003. Case N-533- 1 allows insulation to be removed while the connections are at atmospheric or static pressures. With the insulation removed a direct visual examination is performed to detect previously occurring leakage through the presence of boric acid crystals. Case N-616 allows the VT-2 examination to occur without insulation removal provided the bolting material is resistant to boric acid degradation.

Class 1 and 2 Component S u ~ p o r t s No Class 1 or 2 Component Supports were examined this outage.

Cate~oryL-A. Concrete The Containment concrete surface examination (including grease cans) was performed during the summer of 2005 to satisfy the requirements of 10 CFR 50.55a and the 1992 Edition of ASME Section XI Subsection IWL with the 1992 Addenda. The concrete examinations were performed by a qualified vendor per criteria specified by the 1992 Edition and the 1992 Addenda of ASME Section XI and under the guidance of a Registered Professional Engineer.

Request for Engineering Review 1052234101 was initiated to provide and document technical assistance. Optical aids and flashlights were used when performing the examination that included both direct and indirect visual examination methods. This V T 3 C concrete surface examination required no VT-1C examinations of areas that had not been previously identified during the last concrete visual examination and zero grease leakage was detected on the Containment concrete surface.

Based on the results of the Containment concrete surface visual examination the Containment concrete has no evidence of degradation that warrants further evaluation and repair and remains in an acceptable structural condition and satisfies acceptance by examination criteria per IWL-3211.

Category L-B, Unbonded Post-Tensioning Svstem The Containment unbonded post-tensioning system examination was performed during the summer of 2005 to satisfy the requirements of 10 CFR 50.55a and the 1992 Edition of ASME Section XI Subsection IWL with the 1992 Addenda. The examinations were performed by a qualified vendor per criteria specified by the 1992 Edition and the 1992 Addenda of ASME Section XI. Request for Engineering Review 1052234101 was initiated to provide and document technical assistance. All requirements, including tendon anchorage areas and corrosion protection medium, to satisfy acceptance by examination criteria, per IWL-3221.3 and IWL-3221.4. were met.

Based on the results of the Containment unbonded post-tensioning examination the Containment post-tensioning system has experienced no abnormal degradation and remains in an acceptable condition.

VEGP Unit 1 Thirteenth Refueling Outage Inservice Inspection Report Interval 2, Period 3, 1VR13 Exam ~ o m p o n e nID t Component Description Procedure Report No Results Comments Category B-G-1 11201-V6-001-B01 CLOSURE HEAD STUDS NMP-ES-024-504 S06V1U059 NRI THROUGH B54 B-N-3 11201-V6-001-CSS-01 CORE SUPPORT STRUCTURE VENDOR-VT SAT B-N-I 11201-V6-001-101 VESSEL INTERIOR VENDOR-VT SAT B-N-1 VESSEL CLOSURE HEAD INTERIOR SAT (FSAR 5.3.3.7)

B-D OUTLET NOZZLE N1 INNER RADIUS VENDOR NI AT 22" ENHANCED VT B-D INLET NOZZLE N2 INNER RADIUS AT VENDOR NI 67" ENHANCED VT B-D INLET NOZZLE N3 INNER RADIUS AT VENDOR NI 113" ENHANCED VT B-D OUTLET NOZZLE N4 INNER RADIUS VENDOR NI AT 158" ENHANCED VT B-D OUTLET NOZZLE N5 INNER RADIUS VENDOR NI AT 202" ENHANCED VT B-D INLET NOZZLE N6 INNER RADIUS AT VENDOR NI 247" ENHANCED VT B-D INLET NOZZLE N7 INNER RADIUS AT VENDOR NI 293" ENHANCEDVT B-D OUTLET NOZZLE N8 INNER RADIUS VENDOR NI AT 338" ENHANCED VT B-G-1 11201-V6-001-LO1 THREADS IN FLANGE VENDOR-UT NI THROUGH L54 B-G-I 11201-V6-001-NO1 CLOSURE HEAD NUTS SAT THROUGH N54 B-G-I 11201-V6-001-SO1 CLOSURE WASHERS SAT THROUGH S54

VEGP Unit 1 Thirteenth Refueling Outage Inservice Inspection Report Interval 2, Period 3, lVR13 Exam Component ID Component Description Procedure Report No Results Comments Category B-A 11201-V6-001-W03 (0-180) 0 TO 180 DEG VESSEL SHELL TO VENDOR-UT RI CODE ACCEPTABLE FLANGE WELD 6-A 11201-V6-001-W03 (180- 180 TO 360 DEG VESSEL SHELL TO VENDOR-UT RI CODE ACCEPTABLE 360) FLANGE WELD B-A 11201-V6-00 1-W04 UPPER SHELL TO INTERMEDIATE VENDOR-UT RI CODE ACCEPTABLE SHELL WELD 6-A 11201-V6-00 1-W05 INTERMEDIATE SHELL TO LOWER VENDOR-UT SHELL WELD BA 11201-V6-00 1-W06 LOWER SHELL TO BOTTOM HEAD VENDOR-UT RI CODE ACCEPTABLE - 78.43%

TORUS WELD CODE COVERAGE B-A 1120146-00 1-W07 BOTTOM HEAD TORUS TO BOTTOM VENDOR-UT NI 74.15% CODE COVERAGE HEAD DOME WELD B-A 11201-V6-001-W12 UPPER SHELL LONGITUDINAL WELD VENDOR-UT NI AT 42" 6-A 11201-V6-001-W13 UPPER SHELL LONGITUDINAL WELD VENDOR-UT NI AT 162" B-A 11201-V6-00 1-W14 UPPER SHELL LONGITUDINAL WELD VENDOR-UT NI AT 282" 6-A 11201-V6-00 1-W15 INTERMEDIATE SHELL VENDOR-UT RI CODE ACCEPTABLE LONGITUDINAL WELD AT 0" B-A 11201-V6-001-W 16 INTERMEDIATE SHELL VENDOR-UT NI LONGITUDINAL WELD AT 120" 6-A 11201-V6-001-W17 INTERMEDIATE SHELL VENDOR-UT RI CODE ACCEPTABLE LONGITUDINAL WELD AT 240" BA 11201-V6-001-W 18 LOWER SHELL LONGITUDINAL WELD VENDOR-UT NI 79.03% CODE COVERAGE AT 60" B-A 11201-V6-001-W19 LOWER SHELL LONGITUDINAL WELD VENDOR-UT NI 79.03% CODE COVERAGE AT 180" B-A 11201-V6-001-W20 LOWER SHELL LONGITUDINALWELD VENDOR-UT NI 79.03% CODE COVERAGE AT 300"

VEGP Unit 1 Thirteenth Refueling Outage lnservice Inspection Report Interval 2, Period 3,1VR13 Exam Component ID Component Description Procedure Report No Results Comments Category B-H 11201-V6-001-W204 LIFTING LUG 0" NMP-ES-024-401 S06VlM001 NRI 59.2% CODE COVERAGE B-H 11201-V6-001-W205 LIFTING LUG 120" NMP-ES-024-401 S06V1MOO2 NRI 59.2% CODE COVERAGE B-A 11201-V6-001-W21 BOTTOM HEAD TORUS MERlDlONAL VENDOR-UT WELD AT 0" B-A 11201-V6-001-W22 BOTTOM HEAD TORUS MERlDlONAL VENDOR-UT WELD AT 90" B-A 11201-V6-001-W23 BOTTOM HEAD TORUS MERlDlONAL VENDOR-UT WELD AT 180" B-A 11201-V6-001-W24 BOTTOM HEAD TORUS MERlDlONAL VENDOR-UT WELD AT 270" B-D 11201-V6-00 1-W25 VESSEL TO OUTLET NOZZLE N1 VENDOR-UT NI WELD AT 22" B-D 11201-V6-001-W26 VESSEL TO INLET NOZZLE N2 WELD VENDOR-UT RI CODE ACCEPTABLE AT 67" B-D 11201-V6-001-W27 VESSEL TO INLET NOZZLE N3 WELD VENDOR-UT AT 113" B-D 11201-V6-001-W28 VESSEL TO OUTLET NOZZLE N4 VENDOR-UT RI CODE ACCEPTABLE WELD AT 158" B-D 11201-V6-001-W29 VESSEL TO OUTLET NOZZLE N5 VENDOR-UT WELD AT 202" B-D 11201-V6-001-W30 VESSEL TO INLET NOZZLE N6 WELD VENDOR-UT AT 247" 0-D 11201-V6-001-W31 VESSEL TO INLET NOZZLE N7 WELD VENDOR-UT RI CODE ACCEPTABLE AT 293" B-D 11201-V6-001-W32 VESSEL TO OUTLET NOZZLE N8 VENDOR-UT RI CODE ACCEPTABLE WELD AT 338" R-A 11201-V6-001-W33-RI OUTLET NOZZLE TO SAFE END VENDOR-UT WELD AT 22"

VEGP Unit 1 Thirteenth Refueling Outage Inservice Inspection Report Interval 2, Period 3,1VR13 Exam Component ID Component Description Procedure Report No Results Comments Category R-A 11201-V6-001-W34-RI INLET NOZZLE TO SAFE END WELD VENDOR-UT NI AT 67" R-A 11201-V6-001-W35-RI INLET NOZZLE TO SAFE END WELD VENDOR-UT RI CODE ACCEPTABLE AT 113" R-A 11201-V6-001-W36-RI OUTLET NOZZLE TO SAFE END VENDOR-UT WELD AT 158" R-A 11201-V6-001-W37-RI OUTLET NOZZLE TO SAFE END VENDOR-UT WELD AT 202" R-A 11201-V6-001-W38-RI INLET NOZZLE TO SAFE END WELD VENDOR-UT AT 247" R-A 11201-V6-001-W39-RI INLET NOZZLE TO SAFE END WELD VENDOR-UT AT 293" R-A 11201-V6-001-W40-RI OUTLET NOZZLE TO SAFE END VENDOR-UT WELD AT 338" B-N-2 11201-V6-001 -W41 CORE SUPPORT LUG AT 0" VENDOR-VT NI B-N-2 1120 1-V6-00 1-W42 CORE SUPPORT LUG AT 60" VENDOR-VT NI B-N-2 11201-V6-00 1-W43 CORE SUPPORT LUG AT 120" VENDOR-VT NI B-N-2 11201-V6-001-W44 CORE SUPPORT LUG AT 180" VENDOR-VT NI B-N-2 11201-V6-001-W45 CORE SUPPORT LUG AT 240" VENDOR-VT NI B-N-2 11201-V6-001-W46 CORE SUPPORT LUG AT 300" VEN DOR-VT NI R-A 11208-005-CV11O-RI 3" PIPE DS (FO-0200,201,202) NMP-ES-024-510 SAT

VEGP Unit 1 Thirteenth Refueling Outage lnsewice Inspection Report lntewal 2, Period 3, 1VR13 Exam Component ID Component Description Procedure Report No Results Comments Category R-A 11301-002-11-Rl 6 OUTLET TO FLANGE NMP-ES-024-502 S06V1U070 NRI 78.4% CODE COVERAGE S06V1U072 NRI SOW1U071 NRI R-A 11301-003-1 5-RI 6" OUTLET TO FLANGE NMP-ES-024-502 S06V1U051 NRI 81% CODE COVERAGE S06V1U052 NRI S06V1U073 NRI R-A 11301-015-1-RI 10" OUTLET TO PIPE NMP-ES-024-502 S06V1U054 NRI S06VlU053 NRI

SYSTEM PRESSURE TESTS The following pressure tests on Class 1 and Class 2 components were included in the scope of the maintenancelrefueling outage. These pressure tests included system hydrostatic tests, system inservice tests, and system leakage tests. It should be noted that the hydrostatic test identified was performed to satisfy the "once per ten year" requirements described in ASME Section XI, Code Case N-498-4. Boundaries for the pressure tests are described in the VEGP-1 Inservice Inspection Plan - Second 10-Year Interval document. Examination results are discussed in the applicable sections of this report document. The examination data for these pressure tests is available at the plant site for review upon request.

Svstem Hvdrostatic Test Schedule (HTs)

HT -

Exam. -

Test

-Cat, Description 1 B-P Class 1 Hydrostatic Test (Partially performed)

C-H 11 C-H Containment Spray Train A Open Flow Path Test 12 C-H Containment Spray Train A Open Flow Path Test Svstem Inservice Test Schedule (ITS)

-IT -

Exam. -

Test Number Cat. Description II C-H Centrifugal Charging Pump 1208-P6-002 (Train "A") Discharge Inservice Test 12 C-H Centrifugal Charging Pump 1208-P6-003 (Train "B") Discharge Inservice Test Svstem Leakage Test Schedule (LT)

-LT -

Exam. -

Test Number Cat. Description 1 B-P Class 1 System Leakage Test

REPORTABLE INDICATION

SUMMARY

The following indication identified on the Condition Report was issued due to reportable indications or conditions being observed during the examination of either Class 1 or 2 components during the thirteenth (1 3")

maintenancelrefueling outage at VEGP-I (referenced attachments are available at the VEGP plant site for review upon request):

INF No. Affected ComponentIArea INF Disposition None 11201-V6-001-CSS-01 Condition Report 20061 11 159 was written when the vendor (Westinghouse) observed an anomaly on the "RPV Core Support Structure" during the 10 year reactor pressure vessel examination. The anomaly is believed to be raised metal located on the comer of the 90 degree upper core plate insert (counter clockwise side of keyway).

In conclusion, the indications observed on the bottom surface of the upper core plate clevis inserts will not affect the form, fit, or function of the reactor pressure vessel intemals. Therefore, the upper intemals can be reinstalled without any adverse consequences on their continued operability.

The Indication Notification Form(s) constitute only those reportable indications or conditions observed during the SNC M & IS Department scope of work. Any reportable indications or conditions observed by VEGP Site personnel or outside contractors during their scope of work should be identified bylto the VEGP site in report docurnent(s) which are referenced herein.

OWNER'S REPORTS FOR REPAIRS OR REPLACEMENTS (FORM NIS-2)

The following Owner's Reports for Repairs or Replacements (Form NIS-2) are provided for work activities documented at VEGP-I since the last maintenance/refueling outage (1R12) through the completion of the thirteenth maintenancelrefueling outage (1R13). Reports are identified by their respective traveler number which is denoted on each of the NIS-2 reports. The originals of the NIS-2 reports are filed with their respective traveler packages at the plant site. Only those NIS-2 reports applicable to VEGP-1 are included in this report document. Any attachments, e.g., code data reports, etc.,

referenced in the NIS-2 reports will be made available for review upon request at the plant site.

The NIS-2s for the following travelers are included herein:

FORM NIS-2 OWNER'S R QBJE'BAb~

As Required By The Provisions Of The ASME Code Section XI REPUCEMEN, Traveler# 04118 , y.

e

1. Owner Southem Nuclear Operating Company Dale Apd 25,2005 Name 40 lnvemess Center Perkway, Birmingham. AL Sheel 1 of 1 Address
2. Plant Vogtte Electtic Generating Rent Unit 1 Name Waynesbwo. GA 30830 10402305 Address Repair Organization P.O. No., Job No.. etc.
3. Work Performed by Maintenance Depament Type Code Symbol Stamp WA Name Authorlzatlon No. WA Rant Vogile ExplratlonDate WA Address
4. Identification of System 1202 /Nuclear Service C d n g Water System

. 6. (a) Applicable Construction Code ASME SEC 111 19 77 Editiin, Wnter 1977 Addenda, IVA Code Case (b)Applicable Edition of Section XI Utilized t o r Repairs or Replacements 1889

8. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Sl-Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

SAFETY VALVE CROSBY VALVE d N5690090-0025 N/A 1PSV-8121 1884 REPLACEMENT YES GAGE CO.

6 I

7. Description of Work Rekf Valve W N56900-00-0025 was removed h r inservice testing and was repfacedby re6ef valve Smr N56900-00-0049. Relief velve S N N56900-00-0049 was originaUy installed during construction as 2PSV-8121 andis now being M z e d a s ,

I

8. Test Conducted: Hydrostatic ~ n e u m a t i c a Nominal Operating ~ r e s s u r e m NIA Other Pressure IVA PSI . Test Temp. WA OF
8. Remarks See Item 7 Applicable Manufacturer's Data Reports t o be anached I CERTIFICATE OF COMPLIANCE I I We certify that the statements made in the report a n correct and this ASME Code,Section XI.

Type Code Symbol Stamp N/A replacement repair or m ecem en t confonns to the rules of the I

Expiration Date MA Team Leader OVmerfi Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I I,the undersigned, holding a valid comnission issued by the natlonal Board of Balk and Pressure Vessel Inspectors and the s t k e Province of Geomia and employed by Hatfford Steam W r lnsmcfbn and ~nsufanceCo.  %

4c7of f ;F of to S 0 4 Connecticut have inspected the components described i n thls Owner's Report during the period

,and state that t o the best of my knowkdge and belief, the Owner has performed examinations and taken corredive measures described i n this Owners Report In accordance wlth the requirements of the ASME Cade, Se-ction XI.

By signing this certificate. neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described i n this Owners Repoh Furthemore, neither the Inspector nor his employer shall injury or property damage or a loss of any kind aridng from or connected with this ins comnlssions G ~ a o ~ 3 National Board, State, Province and Endorsements

FORM NIS-2 OWNER'S REP0 b;)H &ild&LACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler # 04120

a Owner Southem Nudear Operating Company Name Date May 13,2005 -

40 lnvemess Center Parkway, Birmingham AL Sheet 1 of 1 Address Plant Vogtle UecMc Genemting Plant Unit 1 Name Waynesboro. GA 30830 10200856 I Address Repair Organization P.O. No.. Job No., etc. I I

Work Performed by Melntenance Department Type Code Symbol Stamp WA Name

,..-- - .- AuthorlzatlonNo. NLA

&nt VogUe Expiration Date WA Address I identification of System . 1305 / Maln Feedwater System I

(a) Applicable Constructlon Code ASME SEC 111 1 8 7 7 Edition. Wnter 1977 Addenda, N/A Code case (b)ApplicaMe Edition of Section XI Utilized for Repairs or Replacements 18@

ldentikation Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Co+

Name of Name of Manufacturer Board Other Year Replaced, Srnped!

Component Manufacturer Serial No. No. ldentificatin Built or Replacement (Yes or Nd)

PIPE SYSTEM PULLMAN WA WA NLA 1987 REPLACEMENT YES !

POWER I

'. I I

I

7. Description of Work I

I

8. Test Conducted: Hydrostatic ~neumatlc [g Nominal Operating PressureD NIA Other Pressure N/A PSI Test Temp. N/A OF
8. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I We certify that the statements made i n the report are correct and this REPLACEMENT confornu to the rules of thb ASME Code. Sectlon XI. repair or replacement Type Code Symbol Stamp N/A

( Certificate of Aythorizatiin No.

- -w Expiration Date N/A I

& 0 Team Leader A. r Signed d Ownedt'Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I I,the undersigned, holding a valid conmission issued by the national Board of Boiler and Pressure Vessel inspectors and the State : w Province of Geomie and employed by H a m  ! of H a m a g m have inspected the components described i n this Owner's Report during the period Februaff 22. 2005 to .4-/7-4< ,and state that to the best of my knowledge and belief, the Owner has performed examlnatlons and taken corrective measures described i n this Omers Report i n accordance with the requirements of the ASME Code, Section !XI.

By slgning this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinatiins and corrective measures described i n this Owners Report. Furthemre, neither the Inspector nor h i s ' employer shall r property dr-ge or a loss of any kind arising from or connected wlth this Convnissions C- Q National b a r d . State, Province and Endorsements

FORM NIS-2 OWNER'S R REPLACEMENTS As Required By The Provisions Of The ASME Coda Section XI I Traveler# 04121

1. Owner Southern Nuclear Operating Company Date July 6,2005 Name 40 lnvemess Center Parkway, Birmingham,AL Sheet 1 of 1 8

Address

2. Plant Vogfle Electric Generafing Plant Unit 1  !

Name

~a~nesbom GA. 308% 19802040 ,

Address Repair Organization P.O. No.. Job No.. etc.  !

3. Work Performed by Maintenance Depament Type Code Symbol Stamp I Name Authorlz~lonNo. WA  !

Plant Vogtle ExplratlonDate WA 1 Address

4. ldentikakon of System 1305 /Main Feedwater System I
6. (a) Applicable Construction Code ASME SEC 111 1 8 7 7 Edition, Winter 1977 Addenda, MA Code c a b (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 18& I
6. Identification Of Components Repaired or Replacedand Replacement Components Repaired, ASME Co$e Name ot Name of Other Replaced, Starnpcd Component I Manufacturer ( Serial No. 1 No. 1 Identification ( Built ( or ~eplacement( (Yes & Nb)

PIPE SYSTEM I PULLMAN 1 N/A I N/A 1 lK2-1305-157-01 1 1987 1 REPLACEMENT I YES !

POWER I I

7. Description of Work Replace pipe section between weldofet and k t downstreamelbow. Code Case N-4161 was used for the insta~abn of this piping. i I
8. Test Conducted: Hydrostatic ~ n e u m a t i c m Nominal Operating pressurea I N I A ~ Other Pressure N/A PSI Test Temp. N/A .F I
9. Remarks Seeltem 7 Applicable Manufacturer's Data Reports to be attached I

CERTIFICATE OF COMPLIANCE I We certify that the statements made in the report are correct and this REPLACEMENT confomts to the rules of the ASME Code,Section XI. repair or replacement I Type Code Symbol Stamp N/A i

Expiration Date MA i Team Leader 0 w n e d r Owner's Designee. Title

/

I CERTIFICATE OF INSERVICE INSPECTION I I,the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geomie and employed by Hartford S z of ~a&or&

Connecticut have inspected the components described In this Owner's Report during the perkd _Merch 2605  !

to 7-7-ax and M e that to the best of my knowledge and belief, the Owner has performed examinations and taken conedtive measures described' in thls Owners Report in accordance with the requirements of the ASME Code. Sedion XI. 1 I By signing this certificate, neither the Inspector nor his employer h k e s any warranty, expressed or implied, concerning the exarninatpns and corrective measures described in this Owners Report.

Commissions Furthermore, neither the Inspector nor his employer shall b e liable in any mannef for any personal injury or property damage or a loss of any klnd arislng from or connected with ]this G w

'1 National Board. State. Province and Endorsements Date I

I

FORM NIS-2 O W N E R ' S ~ ~ h ! & Y O REPLACEMENTS R

As Required By The ~rovisions Of TheiASME Code Section XI Traveler # 04123

1. Owner Southem Nuclear Operating Company Date July 1, 2005 Name 40 lnvemess Center Padway, Birmingham, AL Sheet 1 of 1 Address
2. Plant Vogue Electric Generating Plant una 1 Name Waynesbom. GA 30830 19802040 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by Maintenance Department Type Code Symbol Stamp WA Name Aulhorizatlon No. WA Plant Vog& Explratlon Date WA Address
4. Identification of System 1305 /Condensate and Feedwater System
6. (a) Applicable Construction Code ASME SEC 111 19 74 Editkn, Summer 75 Addenda, WA Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19@
6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired. ASME Code Name of Name of Manufacturer Board Other Year Replaced. Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

PIPE PULLMAN N/A MA N/A 1987 REPLACEMENT YES POWER I

7. Description of Work Replace studs and nuk on 4" Mind flange.
8. Tesl Conducted: Hydrostatii pneumatic NNomi~l Operating Pressure NIAD Other Pressure N/A PSI Test Temp. N/A OF
9. Remarks See Item 7 Applicable Manufacturer's Data Reports t o be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp WA N/A N/A Signed Team Leader II,the undersigned, holding a valid comrnlsslonCERTIFICATE OF INSERViCE INSPECTION issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or I

Province of Ge0qi8 and employed by Hartford Steam Boiler Insaeclion and Insurance Co. of Conneclicut of Harthd.

to 7 05 .

Connecticut have inspected the components described in this OwnerSsReport during the period March 18. 2005 and state that t o the best of my knowledge and belief, the Owner has performed examinations and taken correct'ive measures described i n this Owners Report I n accordance with the requirements of ,the ASME Code,Section XI.

By signing thls certificate, nelther the Inspector nor hls employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspeclor nor hls employer shall anal injury or propedy damage or a loss of any kind arising from or connected with thls Commissions (7,q ap q InspeNr's Signature National Board, State, Province and Endorsements

.<?.!,-b.

'a r ? -4, FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler# 04127 I- L+

I

1. Owner Southern Nuclear Operaling Company Date A@ 8,2005 Name 40 lnvemess Center P a h a y , Binnlngham AL Sheet 1 of ' 1 Address
2. Plant V o w Uectrfc Generating Plant Unlt , 1 Name I Waynesboro, GA 308% 10402535 I Address Repair OrganizationP.O. No.. Job No.. etc. I

/ I

3. Work Performedby Maintenance Department Type Code Symbd Stamp WA Name Authorlzat\on No. WA  !

Plent Vogue ' Explralion Date NLA Address 1

4. identiflcatlon of System 1208 /Chemical end Volume Control System \

I

6. (a) Applicabk Construction Code ASME SEC 111 1 B Z Edition, Mnter 1977 Addenda, N-249-1 Code Ca$e (b)Applicable Edition of Section XI Utilized for Repairs or Replacements lo@ I I
6. Identification Of Components Repaired or Replecedand Repkcment Components  !

National Repaired, ASME C+e Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. identification Buih or Replacement (Yes or N&) ,

PIPE SUPPORT PULLMAN N/A N/A V1-1208-009-H004 1987 REPLACEMENT YES i POWER  !

F I

7. Description of Work Snubber AD153, se"a1 MWiwes repleced with snubberAD153, se"a1 ~ s f J p p o r t s u n m k 0 a n c tesb'ng.

e Clll 903 A I

8. Ted Conduaed: Hydrostatic ~ n e u k a t l c m Nominal Operating ~ i e s s u r e a , .

NIAa Other Pressure #A PSI Test Temp. WA OF I

0. Remarks See Item 7 I

Applicable Manufacturer's Data Reports to be attached I CERTIFICATEOF COMPLIANCE i We certify that the datements made in the report are correct and this replacement conforms to the rules of t+

ASME Code, Section Xi. repair or replacement Type Code Symbol Stamp N/A I N/A ' I I

Team Leader Date CERTIFICATE OF INSERVICE INSPECTION I i,the undersigned, holding a valid commlsslon Issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by m t t of Hatif$

Connecffcut have inspected the components described in this Owner's Report durlng the perlad Julv 22. 2004 to 4 - / $ - O X ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken correcllve measures described in thls Owners Report in accordance with the requirements of the ASME Code. Section 1x1.

By signing this cectiflcate, nenher the Inspector nor h k employer makes any warranty, expressed or implied, concerning the examinati?ns and corrective measures describad in this Owners Report. Furthermore, nelther the inspsctor nor his employer S F #

sonal Injury or property damage or a loss of any kind arising from or connected with thls Commissions GA30.3 InspectaPs Signature National Board, State, Province and Endorsements I Date 4 - JI -o r ,

I

FORM NIS-2 OWNER'S REQ R b G ! M & R E P m c E M E N T s As Required By The Provisions Of The ASME Code Section XI

.. Traveler # 04128

1. Owner Southern Nuclear Operating Company ate Apt# 7,2005 4

I Name 40 l n v e m e Center Parkway, Birmingham,AL Sheet 1 of 1 Address

2. Plant Vogue Electric Generaling Plant Unit 7 Name

~aynesbom.GA 30830 10402534 Address Repair Organization P.O. No., Job No.. etc.

3. ~ o r k ' ~ e r f by o~d Maintenance Depament Type Code Symbol Stamp WA Name AuthorizationNo. MA Plant Voglle Explratlon Date MA Address I
4. Identification of System 1201 /Reactor Codenl System
6. (a) Applicable Construction Code ASME SEC 111 1 9 7 7 Edition. Wnter 1977 Addenda, N-249-1 Code Caw (b)ApplicableEdiilon of Section XI Utilized for Repairs or Replacements 1089

. 6. ldentification Of Components Repaired or Replaced and Replacement Components Natlonal Repaired, AS ME Code Name of Name of Manufacturer Board Other Year Replaced, stamy Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

PIPE SUPPORT PULLMAN N/A N/A ' 'V1-1201-030-H055 1987 REPLACEMENT YES .

POWER

7. Description of Work Snubber AD151, s e W #I59 was replaced with AD151, serial#427 lo suppori survdence tesfinng.
8. Ted Conducted: Hydrostatic ~ n e u m a t i c a Nomlnal Operating p r e s s u r e a NIAN Other Pressure N/A PSI Test Temp. MA T S. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms t o the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp MA N/A Expiration Date N/A Team L e e r I

CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid cormnission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of GeoM and employed by HerflPrd Steam Boiler Inswcbbn end Insurance Co. of Connec&ut of Hampd!

Connecticut have inspected the components described I n this Owner's Report during the period - JuPi 22. 2004 to .A//-& , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken comctive measures described i n thls Owners Report in accordance 4 t h the requirements of the ASME Code. Section 1x1.

By signing this certiflcate, neither the Inspector nor his employer makes any warranty, expressed or i m p l i , concerning the examinations and correctbe measures described i n this Owners Report. Furthermore. neither the Inspector nor hls employer shell erronal injury or property damage or a loss of any kind arising from or connected wlth !his Commissions GA 3 Natlonal Board, State, Provlnce and Endorsements Date 4-fl-5

T- I ORIGINAq

- r - -

, !I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS I

I As Required By The Provlsions Of The ASME Code Section XI

1. Owner Soulhem Nuclear Operating Company Date Traveler W 04~1m5 04132 1 9 I

I Name f

I 40 lnvemess Center Parkway, Birminoham, AL Sheet .1 of 1 I I

Address

2. Plant Vogtle Electric Generating Plant Unlt 1 I Name I Waynesbom, GA 30830 WO# 10303320 I

. Address Repair Organization P.O. No., Job No., etc. I I

3. Work Performed by Maintenance Department Type Code Symbol Sump WA Name Authorlzatlon No. N/A I Plant Vogtle Explratlon Date MA Address I
4. ldentificatlon of System 1208 /Chemical and Volume Contrd System I
5. (a) Applicable Construction Code ASME SEC 111 1 9 7 7 Edltlon, Winter 1977 Addenda, WA code c a b (b)Appiicable Edition of Section XI Utillzed for Repairs or Replacements 1 9 s I I

1

6. ldentlficatlon 01 Components Repairedor Replaced and Replacement Components  !

I Name of Name of Other Component Manufacturer : Serial No. No. . ldentlfication Built or ~eplacement (Yes or ~ b )

PIPE PULLMAN POWER WA WA V1-1208-488-H002 1987 REPLACEMENT YES )

SUPPORT ROWCTS I I

7. Description of Work Snubber PSA-1, serial I23069 was repkced with a Lisega Type 30 snubber serial #W61596(Y057 in accordance I

with DCP 99-VANOO3.3.

I

, 8. Test Conducted: Hydrostatic ~ n e u m a t i c n Nomlnal Operating ~ r e s s u r e n Ii N I A ~ Other Pressure WA PSI TestTemp. WA .F . 1 I

9. Remarks See Item 7 i Applicable Manufacturer's Data Reports to be attached ' I i

CERTIFICATE OF COMPLIANCE I We certify that the statements made in the report are correct and this replacemnt conforms to the rules of the ASME Code,Section XI. repair or replacement II I

Type Code Symbol Stamp WA Certificate WA Expiration Date WA '

$, Signed Team Leader Date

@ OyaBr or O r 3 w I

I CERTIFICATEOF INSERVICE INSPECTION I,the undersigned, holding a valid commlsslon issued by the national Board of Boiler and Pressum Vessel Inspectore and the state or Province of and employed by Hartford Steam Boiler In~oectionend Insumrice Co. of Connecticut ; of HartfOld. Connecticut have Inspected the components described in this Owner's Report during the period 07/22/04 1 to 5, and state that to the best of my knowledge and bellef, the Owner has performed examlnatlons and ta'ken correctivtzurea b s c r l ~ in th\a.Ownera Report in accordance wlth the requirements of the *PME code, Sectd Xi.

I By algnlng this certificate, nelther the Inspector nor hlr employer makes any warranty, expressed or Implled. concernlngi the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be llable In any manner for any. personal. injury

. . or propem

~. . dsmage Commissions

- or a loss of any klnd arlslng GXdaf

- from or connected with fthis I Natlonat Board, State, Province and Endorsements 1 ate 5- 44-f I I

FORM NIS-2 OWNER'S Q f l 6 U B h R REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler# 04134 Owner Southem Nuclear Operating Compeny Date Aptil 11, 2005 1 I

Name 40 lnvemess Center Padway. Birmingham, AL Sheet 1 of 1 Address I I

Plant VogLle Electric Generating Uant Unit 1 Name I Waynesbom, GA 30830 10303325 I Address Repair Organization P.O. No., Job No., etc.

Work Performed by Maintenance Department Type Code Symbol Stamp WA Name Authorization No. NIA Rant Vogue Explratlon Date WA Address Identification of S y s t m 1302 / Auxihary Feedwater System (a) Applicable Construction Code. ASME SEC 111 1 9 7 7 Edition. Wnter 1977 Addenda. N-249-1 Code C a e I

(b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 IdentincationOf Components Repaired or Replaced end Replacement Components National Repaired, ASME Co&

Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or N&)

UPE SUPPORT PULLMAN N/A MA 1-1302-107-H010 1987 REPLACEMENT YES i POWER

7. Descriptionof Work Snubber AD1601, serial #322 was repleced with snubber Usega 306256RF3. seriel#03615425tD30 in accordend.
8. Test Conducted: Hydrostatic ~ n e u m a t i c a NominalOperating pressurea NIAB Other Pressure W A PSI Test Temp. N/A *F B. Remarks See Item 7 I Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE i We certify that the statements made i n the report are correct and this mplacement conforms to the rules of the ASME Code.Section XI. repair or replacement Type Code Symbol Stamp WA Certificate of Authorization No. N/A Expiration Date N/A Signed Team Leader Date CERTIFICATEOF INSERVICE INSPECTION I.the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State , or Province of Geomie and employed by HaMord S t e e of lfat&d Conneclicut have inspected the components described in this Owner's Report during the period July 22, 2004 I to 4 - 1 2 - u . ~ , and state that to the best of my knowledge and belief, the Owner has performed e x a m i n a t i and taken corredthre measures described in this Owners Repor( in accordance with the requirements of the ASME Code.Section XI. 1 By signing this certificate, neither the tnspectoimi his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthemre, neither the Inspector nor his employer dhall be llable in any manner for any personal lnlury or property damage or a loss of any kind arising f r a n or connected wlth fhls inspe i Commlsslons GAm-?

I Inspect0 s Signature National Board, State. Province and Endorsements

FORM NIS-2 OWNER'S REPORT O QRlGlNAL EPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code S e d i XI Traveler# 04135 Owner Southern Nuclear Operating Company Date April 17,2005 Name .

40 lnvemess Center Parkway, Wingham, AL Sheet 1 of 1 Address Plant Vogue Electdc Generating Plant Unit 1 Name Waynesbom. GA 30830 10303324 Address Repair OrganizationP.O. No., Job No.. etc.

Work Performed by, Maintenance Department Type Code Symbol Stamp WA Name Authorlzatlon No. WA Plant Vogue ExpirationDate WA Address Identification of System 1302 /Auxitary Feedwater System (a) Applicable Constmction Code ASME SEC 111 1 9 7 7 Edition. Wnter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacementsla@

ldentification Of ComponentsRepaired or Replacedand Replacement Components National Repaired. ASME Code Name of Name of Manufacturer Board Other Year Replaced. stanped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

PIPE SUPPORT PULLMAN WA N/A 1-1302-110-H013 1987 REPLACEMENT YES POWER

7. Description of Work Snubber AG1601. serial #I01 was replaced with snubber Usega 306256RF3, serial#O3615425Q22 in accord8n~e.

with DCP 99-VAN0033.

8. Test Conducted:

NIA Other a a Hydrostatic ~neumatic[SJ Nominal Operating ~ r e s s u r e D Pressure N/A PSI Test Temp. N/A OF .

9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be anached CERTlFICATE OF COMPLIANCE We certify that the slat-nts made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp MA CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Provlnce of Geonria and employed by Hamord Sham Boiler Inspection and Insurence Go. of Connecticut of Hartford.

Connecficut have inspected the components described in this Owner's Report during the period Julv 22. 2004 to 4-12-d.47 ,and slate that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Chvners Report in accordance with the requirements of the ASME Codc Sectinn XI.

By signing this certificate. neither the Inspector nor his employer makes any warranty, expressed or implled, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall nal injury or property damage or a loss of any kind arising from or connected with this Commissions f f a National Board. State, Province and Endorsements Date 4/2-85

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Sectlon XI Traveler lD W 138

1. Owner Southem Nuclear Operating Company Date W21/05 Name 40 lnvemess Center Parkway, Birmingham, AL Sheet 1 of 1 Address
2. Plant Vogtle Electrlc Generating Plant Unit 1 Name Waynesboro, GA 30830 WO# 1W02525 Address Repair organization P.O. No., Job No., etc.
3. Work Performed by Maintenance Department Type Code Symbol Stamp hVA Name , AulhorizatlonNo. WA Plant Vogfie ExpiralionDate WA Addresa
4. Identification of System 1201 /Reactor Coolant System
5. (a) Applicable Construction Code ASME SEC 111 1 9 7 1 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Sectlon X I Utilized for Repairs a Replacementa l9@
6. ldentificatlonOf Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. ldentiflcatlon Built or Replacement (Yes or No)

PIPE PULLMAN POWER WA WA V1-1201-029-HO21 1987 REPLACEMENT YES SUPPORT RODUCTS

7. Description of Work Snubber AD-501, serial #502 was replaced with an AD-501 serial #406 to support surveillance lesting.
8. Test Conducted: Hydrostatic 0 pneumatic0 Nominal Operating pressure0 NlAm Other Pressure M A PSI Test Temp. MA "F
9. Remarks See Item 7 Applicable Manufacturer's Date Reports to be attached CERTIFICATE OF COMPLIANCE We certity that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp

, N.A rylA Expiration Date IWA Owner #owner's Desianem. Title Team Leader Date *;Aae-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the natlonal Board of Boiler and Pressure Vessel inspectors and the State or Province of Geomia and employed by Boiler Insaection and Insurance Co. of Connecticuf of toHaF9f ~wrnecticut, have inspcted the cornponenta described in this Owner's Report during the period 07/2&104 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective meesures described In this Owners Report in accordance with the requirements of the ASME Code, W i n XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations end corrective measures described in this Owners Repoh Furthermore, neither the Inspector nor his employer shall property damage or a loss of any kind arising from or connected with this Commissions GA National Board, State, Province and Endorsemenis Data 53 - - 0.r

ORIGINAL FORM.NIS-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating Company Date Traveler #

04/25/05 W 142 4

Name 40 lnvemess Center Parkway, Birmingham, AL Sheet 1 of 1 Address

2. Plant voQie Electric Generating Plant Unlt 1

.Name Waynesboro,GA 30830 WO# 10402522 Address Repair Organization P.O. No., Job No., etc.

3. Work Performedby Maintenance Department Type Code Symbol Stamp WA Name Authorization No. WA Plant V a l e Expiration Date WA Address
4. ldentificatlonof System 1201 /Reactor coolant System
5. (a) Applicable Construction Code ASME SEC 111 1 9 7 7 Edition, Winter 1977 Addenda, #A Code Case (b)Applicable Edition of Sectlon XI Utilized for Repairs or Replacements 1989
6. IdentificationOf Components Repaired or Replaced and ReplacementComponents I I I I National 1 I I Repaired, I =ME Code I Name at Name of Manufacturer Board Other Year Repled, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

PIPE PULLMAN POWER #A WA VI-1201-053-H005 1987 REPLACEMENT YES SUPPORT RODUCTS

7. Description of Work Snubber PSA-35, serial #11250 was replaced with a PSA-35 sedal #I2257 to support surveillance testing. A replacement load stud with nuts was also installed on this support.
8. Test Conducted: Hydroshtlc ~neumatic[7 ~ominalOperating ~ r e s s u r e n

. N/A@ Other Pressure M A PSI Test Temp. MA S

9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the etatements made in the repart are correct and thle replacement conforms to the rules of the ASME Code,Section XI. repalr or replecement

,. Type Code Symbol Stamp WA

" Owner MOwner's Designee, Title Team Leader Date I

I CERTIFICATE OF INSERVICEINSPECTION I,the undersigned, hoidlng a valid commission issued by the national Board of Boiler and Pressure V e m l Inspectors and the State or Province of Geomia and employed by Hadford Steam Boiler Insmction and l n s u m m Co. of Connectticut of Hartlord. Connecticut have inspected the components described in thls Owner's Report during the period 07127/04 to ,5-c/-= , and state that to the best of my knowledge and bellef, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of the ASME Code, Sectlon Xi.

By slgnlng thls certificate, neither the Inspector nor hls employer makes any warranty, exproseed or implied, concerning the this Owners Report. Furthermore, neithsr the Inspector nor hls employer shall property damage or a loss of any kind arlslng from or connected with this Commissions GA30-3 NationalBoard, State, Provlnceand Endorssments Date 5-4-@,

ORIGINAL  !

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler l 04 145

1. Owner Southem Nucleer Operating Company Date 04/25/05 Name 40 lnvemess Center Padway, Birmingham, AL Sheet 1 of 1 Add-
2. Plant Vogtle Electric Generetina Plant Unit 1 Name Waynesboro,GA 30830 WO# 10402516 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by Maintenance Department Type Code Symbol Stamp WA Name Authorization No. ' WA Plant Vogtle Expiration Date WA Address
4. Identificationof System 12W /Safety Injection System
5. (a) Applicable Construction Code ASME SEC 111 1 9 n Edltlon, Winter19?7Addmda, N/A Code Ca (b)Appllcabie Edition of Section XI Utillzed for Repalrs or Replacements 19& ,
6. IdentificationOf Components Repaired or Replaced and Replacement Components National Repaired, ASME Ca Name of Name of Manufacturer Board Other Year pi^, Stampe Component Manufacturer Serial No. No. ldentlflcetlon Built or Repiecement (Yes or h PIPE PULLMAN POWER MA WA V1-1304423-010 1987 REPLACEMENT YES SUPPORT RODUCTS
7. Description of Work Snubber PSA-10, serial #I7531 was replaced with a PSA-10 serial #I5827 to support su#eiI&nce testing. fhe removed snubber (serial# 17531) failed an insewice functional test as documented by CRX 2005102199.
8. Test Conducted: Hydrostatic pneumatic0 Nominal Operating pressure0 NIA~ Other Pressure WA PSI Test Temp. N/A OF
9. Remarks See Itam 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replamnt conforms to the rules of ASME Code,Section XI. repair or replacement

\ Type Code Symbol Stamp WA WA Expiration Date WA I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the national Boerd 01 Boiler and Pressure Vessel Inspectors and the !

or Province of Georgieand empioysd by n ecticut have inspected the components described in this Owner's Report during the period a3!$s$

Hrlf and state that to the best of my knowledge and belief, the Owner has performed examinations and t corrective measures described In this Owners Report In accordance wlth the. requirements of the ASME Code. Sectlor 07EW By signing thls certificate, neither the Inspector nor his employer makes any warranty, expressed or i m p l i i , concerning examinations and cormctive measures described In this Owners Repoh Furthermore, neltnef the Inspector nor his employer nal injury or property damage or a loss of any kind arising from or connected wlth Commissions G ,ajr National Board, State,Province and Endomements

( Date 57 4 - 0 5

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1 Owner Southern Nuclear Opemting Company Date Traveler #

Wn1/05 04 150 Y

r Name 40 lnvemess Center Parkway, Birmingham, AL Sheet 1 of 1 Address

2. Plant Vogtle Electric Generating Plant Unit 1 Name Waynesboro, GA 30830 WO# 10402521 Address Repair Organization P.O. No., Job No.,etc.
3. Work Performedby Maintenance Department Type Code Symbol Stamp WA Name Authorization No. WA Plant Vogtle Expiration Data WA Address
4. Identification of System 1204 / Safety Injection System
5. (a) Applicable Construction Code ASME SEC 111 1 9 n Edition, Winter 1977 Addenda, N/A Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19@
6. ldentification Of Components Repaired orReplaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Bosrd Other Year Replaced, Stamped Component Manubcturer Serial No. No. Identification Bullt or Replacement (Vw or No)

PIPE PULLMAN POWER NLA WA V1-1204-125-HO17 1987 REPLACEMENf YES  :

SUPPOFlT RODUCTS

7. Description of Work Snubber PSA-35, serial W11484 was replaced with a PSA-35 serial 11 1253 to support surveilIance testing.
8. Teat Conducted: Hydraatetic ~ n e u m a t i c u Nominal Operating ~ r e s a u m O MIA@ Other q pressure WA PSI ~ e s~emp.

t WA OF

9. Remarks Seeltem 7 Applicable Manufacturer's Data Reports to be attached CERTiflCATE OF COMPLIANCE We certify that the stapments made in the report are w m c t and this replacement conforms the rules of t$e ASME Code,Section XI. repair or replacement Type Code Symbol Stamp WA I, the undersigned, holding a valld commission Issued by the national Board of Boiler and Pressure Veosel Inspectors and the StJlte or Province of S;eoroieand employed by. Hartfonl Steam Boiler lnsoection and Insurance Co. of Connecticul of Hadford. Connecticut have inspected the components described in thls Owner's Report during the p l o d 07i27/04 to 5 C S , and state that to the best of my knowledge and belief, the Owner has vrtormed examinatlona and t a 9 n correctlw measures described in this Owners Report in accordance with the requirements of the ASME Code. Sectlon 0x1.

By signing thls certificats, neither the Inspector nor hls employer makes any warranty, expressed or implled, mncerning the examinations and oorrectlve measures descrlbed In this Owners RepoR Furthermore, nelther the Inspector nor his employer s4all property damage or a loaa of any kind ariaing horn or connected with @is Commlasions GIal # .

National Bsrd, State, Provinceand Endorsembnta

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPA1R.S OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operaling Company Date Traveler l 04nYo5 C4152
9 Name 40 lnverness Center Pamay, Birmingham AL Sheet 1 of 1 Address
2. Plant Vogtle Electric Generating Plsnt Unit 1 Name Waynestwm, GA 30830 WO# 104(12504 Address Repair Organization P.O. No., Job No.,etc.
3. Work Performed by Maintenance Department Type Code Symbol Sump hUA Name Authorization No. hUA Plant Voglle Expiration Date MA Address
4. ldentffiiatlon of System 1208 /Chemical and Vdume Conttvl System
5. (a) Applicable Construction Code ASME SEC 111 19 nE d i t h , Winter 1977 Addenda, N-2441 Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. IdentificationOf Components Repaired or Replaced and Replacement Components National Repaired, ASMEC*

Name of Name of Manufacturer Board Othw Year Replaced, sumw Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

PIPE PULLMAN POWER WA MA V1- 12OB-449-H013 1987 REPLACEMENT YES :

SUPPORT RODUCTS

7. Description of Work Snubber A D 4 1, serial #a92 was replaced with an A 0 4 1 serial Y698 lo supjmrt surveillilnce testing.

I

8. Test Conducted: Hydrostatic q ~ n e u m a t i c o Nominal Operating ~ r e s s u r e O NIA~ Other 0 Pressure MA PSI Test Temp. MA OF
9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report am correct and thls replacement conforms to tha rules of the ASME Code.Section XI. repalr or replacement 1 Type Code Symbol Stamp CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the Sfets or Provlnce of Georoia and employed by k H m 'ler o f Har?ford. Connecticut have inspected the components described in this Owner's Fieport during the period 0 7 1 2 7 ~ ~:

to C--B-n5 , and state that to the best of my knowledge and belief, the Owner has pedonned examiwtiona and taljen corrective measures described in thls Owners Report In accordance with the requirements of the ASME Code,Section XI.

9 I By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or lmpiled, concerning the examinations and cortectlve measurns described in this Owners RepoR Furthermore. neither the Inspector nor his employer s*ll be liable in any mwner for any personal injury or property damage or a loss of any kind arising from or connected with this Cornmissions I

Nationai Board, State, Provinceand Endorsements Date .<-.yaJZ I

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

, . reveler # 04155 Y

1. Owner Southem Nuclear Operating Company Date Apt# 8,2005 Name 40 lnvemess Center Parkway. Birmingham,AL Sheet 1 of 1 Address
2. Plant VogUe Electric Generating Plant Unit 1 Name Waynesboro, GA 30830 10402528 Address Repair OrganizationP.O. No., Job No.. etc.
3. Work Performed by Maintenance Oepattment Type Code Symbol Stamp WA Name Authorlzatlon NO. WA Plant Vogue ExpirationDate WA Address
4. ldentlfication of System - 1301 /Main Steam System
5. (a) Applicable Construction Code ASME SEC 111 1B 77 Edition. Wnter 1977 Addenda, N-249-1 Code Caqe (b)Applicable Edition of Section XI Utilized for Repairs or h3acements 1989
6. ldentification Of Components Repaired or Replacedand Replacement Components National Repaired, ASME C w Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. ' No. Identification Built or Replacement (Yes or No)

PIPE SUPPORT PULLMAN N/A hVA V1-1301-107-HOO5 1987 REPLACEMENT YES ;

POWER

7. Description of Work Snubber AD-5501, serfal#254 was replaced with snubber Lisega 307256RF4, serial W4616450/029 to suppori surveilance testing. The removed snubber (setfal#254)failed en insembe hinclional test 8s documented by CR#2005102107
8. Test Conducted: Hydrostatic ~ n e u m a t k a Nominal Operating ~ r e s s u r e m .

NIA a Other Pressure N/A PSI Test Temp. WA .F

9. Remarks Seeltem 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATEOF COMPLIANCE We certify that the statements made i n the report are correct and this replacement conforms to the ruks of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A hVA Expiration Oate WA  ! '

Team Leader Date CERTIFICATEOF INSERVICE INSPECTION I,the undersigned, holdlng a valid comrnisslon Issued by the national Board of Bolkr and Pressure Vessel inspectors and the State or Province of Geomia and employed by of Ha@ni, Connecllcut have inspected the compgnents d-crlbed in this Owner's Report durlng the period Juhr 27. 2004 to L/,//-6 ,and slate that to the bed of my knowledge and belW. the Owner has performed exslllinatkns and taken cornctjve measures descrlbad in this Owners: Report In accordance wlth ths requirements of the ASME Code,Section XI.

By signing thls certificate, neither the Inspector nor his employer makes any warranty, expressed or implled, concemlng the examinations and corrective measures descrikd in .this Owners Report. Furthermore, nelther the Inspector nor hls employer shall mnal injury or property damage or a loss of any kind arbsing from or connected with this Commissions GA;lbf Natlonal Board, State, Province and Endorsements Date 4-/)45

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR. REPLACEMENTS As Required By The ProvisionsOf The ASME Code Section XI Traveler # 04 157

1. Owner . Souihem Nuclear Opefating Company

, Date 04/2 1/05 Name 40 lnvemess Center Parkway, Blmingham, AL Sheet 1 of 1 Address

2. , Plant Voglle Electric Generating Plant .Unit 1 Name Waynesboro, GA 30830 WO# 10303331 Address Repair Organization P.O. No., Job No., etc.

Work Peflormed by hfaintenance Department Type Code Symbol Stamp N/A Name Authorization No. WA Plant V0gtle Erplrsdon Dote WA Address Identificationof System 1208 / Chemical and Volume Control System

5. (a) Applicable Construction Code ASME SEC U 1 9 7 7 Edltlon, Winter 1977 Addenda, N-249- 1 Code C a y (b)Applicable Edition of Section XI Utilizedfor Repairs or Replacements 19@
6. IdentificationOf Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, stamped Component Manufacturer Serial No. No. identification Built or Replacement (Yes or Nb)

PIPE PULLMAN POWER NLA WA V1-1208-055-H046 1987 REPLACEMENT YES SUPPORT RODUCTS

7. Description of Work Snubber AD- 153, sehl#212 was replaced with a Lisega Type 30 snubber serial #0361596Q1067 in accordance with DCP 99-VAN0033 The removed snubber (serial# 212) failed an insewice functional test as documented by CR# 200510214 1.
8. Test Conducted: Hydrostatic [7 ~neumatic[7 Nominal Operating ~ r e ~ u r e m WAN Other Pressure W A PSI Test Temp. NLA "F
9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We cenlfy that the statements made In the reporl are correct and thle replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp WA WA Expiration Date MA Team leader Date 4A -/ -

CEWFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valld commlsslon Issued by the national Board of Boller and Pkssure Vessel Inspectors and the State or Province of Geomia and employsd by Hartfotd S t e e a of

,Hartlord, Connecticut have Inspected tha components described in thls Owner's Reporl durlng the perlod 07/2&04 to 5-3-0s ,and state that to the best of my knowledge and belief, the Owfmr has perfwmed examinations and taken corrective measures described In thls Owners Report In accordance wlth the requirements of the ASME Code, Sectlon XI.

By signing this certlicste, neither the Inspector nor hls employsr makes any warranty, expressed or implled, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor hls employsr qhall sonal injury or property damage or a loss d any klnd arlclng from or connected wlth this Commissions G A ;ld3 National Board, State, Province and Endorsements Date 5-3-05'

As Required By The Provisions of The ASME Code Section XI Traveler # 04158

1. Owner SorrMem Nuclear Operating Company Date Apd 11. 2005 /

Name 40 lnvemess Center Parkway, Birmingham. AL Sheet 1 of 1 Address

2. Plant Vogile Electric Generaiing Plent Unit 1 Name Weynesbom. GA 30830 10402530 Address Repalr Organization P.O. No.. Job No., etc.
3. Work Performed by Maintenance Department Type Code Symbol Stamp WA Name .. Authorlzatlon No. WA Rent Vogtle Explratlon Date N/A Address
4. Identification of System . 1302/ Auxitary Feedwater System 6 (a) Applicable Construction Code ASME SEC 111 19 77 Edltlon, Wnter 1977 hddenda, K249-1 Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification Of Components Repaired or Replaced and Replacement Conlponents National Repaired, ASME Code Name of Name of Manufacturer ' Board Other Year Replaced. Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

PIPE SUPPORT PULLMAN WA WA 1-1302-70&H010 1987 REPLACEMENT YES POWER

? -

7. Descriptionof Work Snubber AD1601, s e w #688 was replaced with snubber Lisega 306256RC7, senal#0461594QX)56in accordande.

witt, DCP 99-VAN0033.

8. Test Conducted. Hydrostatic ~ n e u m a t i c n Nominal Operating pressurea NIAm Other Pressure WA PSI Test Temp. WA OF
9. Remarks See Item7 Applkable Manufacturer's Data Reports to be alteched CERTIFICATE OF COMPLIANCE We certlty that the statements made i n the report are correct and this mP,acement conforms to the rules of the ASME Code.Section XI. repair or replacement Type Code Symbol Stamp WA - -

MA Expiration Date WA Team Leader Date CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geode and employed by m m of ~ a o f r a to &-o$ .

Conneckut have inspected the components described i n thls Owner's Repolt during the period Auaust 3. 2004 and state that to the best of my knowledge and belief. the Owner has performed examinatlons and taken corrective measures described In this Owners Report i n accordance with the requirements of the ASME Code. S e c t i i XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty. expressed or I m p l i i . concerning the examinations and corrective measures described In this Owners Report. Furtbrmore, nelther the Inspector nor his employer shaH nal Injury or property damage or a loss of any kind arising from or connected with this Commissions 203 National Board. State, Province and Endorsements oate -

4/305 -

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code W o n XI I

Traveler# 04 1 70

1. Owner Southern Nuclear Operating Company Date WW Name 40 lnvemess Center Palkway, Bimingham, AL Sheet 1 of 3 Address

~ ~.- . -

2. Plant VogNe Electric Generstlng Plant Unit 1 Name Waynesbom, GA 30830 WO# 1010031501 Address Repair Organization P.O. No., Job No..etc.
3. Work Performed by Maintenance Department Type Code Symbol Stmp WA Name Authorbalm No. WA Plant Vogtle ExplratlonDate WA Address
4. Identificationof System 1208/Chemical and Volume Control System
5. (a) Applicable Construction Code ASME SEC 111 1 9 7 7 Edition, Winter 1977 Addenda, NLA Code Case (b)Applicabb Edition of Section XI Utilized tor Repairs or Replacements 198Q Mm Code Case N-554-2
6. Identification Of Components Repaired or Replacedand Replacement CompofIentS National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced. Stamped Component Manufacturer Serial No. NO. Identification Built or Replacement (Yes or No)

VALVE FISHER 6499379 3238 1HV0128 1978 REPLACEMENT YES CONTROLS co.

7. Descriptionof Work Valve plug was replaced. A copy of Fom N-2 for the replacement plug (S/N AEB987-1) is alteched.
8. Test Conducted: Hydrostatic q ~ n e u m a t i c O N o m i ~Operating l ~ressumO WAB Other Pressure NLA PSI Test Temp. NLA OF
9. Remark8 See Item 7 Applicable ~anufacturer'sData Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rubs of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NLA Expiration Date NLA Team Leader t $A4c CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission imued by the national Board of Boiler and Pressure Vessd Inspectom and the State or Province of and employed by Ha-er-nd Insurance Co. of Connecljcut OfHemord.

Connecf&& haw inspected the components &scribed in this Owner's Report during the period 12/14/W to R-30-w ,and state that to the best of my knowledgeand b e l i , the Owner has performed examinations and taken conectiva mesrurer described In this Ownem Report in accordance with the requirements of the A W E Code,Section XI.

By signing this certificate, neither the Inspector nor his empkyw makes any warranty, expressed or impliad, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inepector nor hi$ employrr shall rsonal injury or property damage or a loan of any kind arising from or connected with this Commmsions 20.3 National Board, S v , Province and Endorwmenta Date p-30-05

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES* k b r # 0+1,70 As Required by the Provisions of Ihe ASME Code, Section Ill she* 2 0 4 3 ,

~ o tot exceed One Day's Production 025-N230160764 I. M.nufbeUd and fmified h!. FISHER CONTROLS lNT'L.LLC,205 SOUTH CENTER STREET,MARSHALLTOWN, 1A 50158

._ . (name a d &s) of NPT C r r t i l c n ~Holdct)

2. h4mubctu~dfor Control.Southenr Nuclw Plank 3850 Lakcfield Dr. Suwmce, GA 30024

( n ~d ~~ddrcS3of p ~ r c b m )

3. h t i o n ofinp(lJLtiaa VOEUCUcchic Gm. Plant, 7821 River R o d Warnthorn. CSA 30830 (nunc andddles)
4. Type 11,432 11 Rev. B SA479S31600 . 75 KSl NIA 2004 (drawingno.) , (mal'l. spa, no.) (Imsile mgh) (Cm) (yurbuilt)
5. ASME Codc. Section Ill: 1971 S u n m n 1972 2 NlA (cditioa) (addcodadatc) (dm) (Code Cucw.) :
6. Fabriakdin .fcordaMwiwonst Spsc.(?a 2 only) NIA Revidon NIA Dale NIA '

(4

7. R t ~ m l k s Dcsipn: ASME B W C ' S ~ 111,1971

~: Edition S u m 1972 Adden&. Class 2 OUlcr. ASME B W C Slc llI, 1989Edition,No AMcndq CI.g 2

8. Nom Ibicknes (in.) NIA Min.dtoigp thick- (in) NIA Dir ID (A Bin.) NIA .LmgUI o w n l l (A & i n ) NIA :
9. When appliable, W ~ c l t Holders' r D.lr R q m u~c for uch itan of thisrepotl:

- Fhi m A p p u r t c ~ n a Heat Number SaiJ N t m h r

+-(I) AE89R7-I 13949 (2) AEA987-2 13949 (3)

(4)

(5)

(6)

(7)

(8) . ..

(9)

(10)

(1 1)

(12)

(13)

(14)

(1s)

(16)

(17)

(18)

(19)

(20)

(21) .

(22)

(23) . .

(24)

(25)

10. Dedp Rclsurc 600 . psi. Trmp. 400 T. Hydm. fed prraure NIA at m.T (whm appliublc)

'Supplanen(ll info&iom in tbc f m o f h a q Qetcber, or dmwilyr may b c . u d provided (1) d= is 8 112 x 11, (2) i n f d o n in ilrrnt 2 and 3 o n (hisI)rlr.R v is included on u c b &cat, (3) each e&ct is aumhmd lad the n u d m of sheets is rccor&d at h e f ~ of p Ibis fonn

FORM N-2 (back) 4 Mk Serinl No. AER9R7-I .-2 CERTIFICATION OF DESlGN Dcigr rpecihulipnrcertifiedhy Hmry P.Leon~ld P.E. Sulc PA Rc& no. 23938-E (when clppliublc)

Deigr repo~i*certified hy NIA P.E.She NIA Reg. no. NIA (when applicable)

CERTIFICATE OF SHOP COMPLIANCE We cerlit) &at Lhe grtnncnh nn& in this r e p l am correct a d ( h t this (these) Piu@SCrmAsy wnhms tn (bc rules ofconmclion of the ASME C&. Section 111.

NIT Cdfiark of AuLborization No. 1930 Expins 11-11-20U4) h me g oc/ ~m FISHER CONTROLS WTL LLC /&Ad (NPTCcrlifrak Holder) (authoril$d tqtresmtaiive)

CERTlFlCATE OF SHOP 1NSPECTlON I. (be undnsipcd holding CI valid comr6aiomiasued by the National Boud ofBuilcrand Rtssurr V d Inqcctnrs and Lhc state or Province o f Io w ud cq~loycdby HwtLrd Stem Bailer of CT of Hadord,CT have inspected (btsritem dcsnhcd in his Data Rqmi on 9- 36-eoy andNtc~1Inlhc best of my knwrlodgr md belief. the Cnri6ute Holdsr hs Eabriukd BCIC p m ot rppurlenanon,in accorQaa wicb & ASME Code, Section 111. Escb +liakd hr been s u ~ ~ f o r ~ . o o L h c & t e ~ ~ .

B y signing (his &6cak, n e i k (be inrpec(mnw his anploys d e s any wmanty, e x p r e d or implied, c o d a g chc equipment & m iin (his the RcpDfi Furlbcm#m. nsilkr (be inspector nor his eaploya shll k l i l e in any rmumer for my p d injury or & m q c or loss of any kind d i g Sum a with thin m@op he @d~Y signed 43-dw-7 (Aubtind lqcclm

~onrmissions 83% a (N.l'l.Bd.(i.sndoncmslra)~orprov.~dno.)

>- . PRlGlNAL FORM NIS-2 OWNER'S RE ORT FOR REPAIRS OR REPLACEMENTS As Required By he Provisions Of The ASME Code Section XI Traveler #, 041 73 4I Owner Soulhem Nudeer Operating Company Date Apt# 15,2005 Name 40 lnvemess Center Parkway, Bimdngham, AL Sheet 1 of 1 Address Plant Voglle Electric Generating Plant Unit 1 Name 4 Waynesboro, GA 30830 roraJm ~oUuwUia 41bl"?

Address Repair Organization P.O. No., Job No., etc.

Work Performed by Maintenance Department Type Code Symbol Stamp WA Name Authorlzatlon No. WA Plant VogL Explratbn Date WA Address Identification of System 1201 /Reactor Coolant Sysfem (a) Applicable Construction Code ASME SEC 111 1 8 7 7 Edition, Wnter 1977 Addenda. N-249-1 Code C a y (b)Applicable Edition of Section XI Utilized for Repairs or Replacements1088 Identification 01 Components Repaired or Replaced and ReplacementComponents National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced. Stamped Component Manufacturer Serial No. No. Identification Built or Replacement IYes or No)

PIPE SUPPORT PULLMAN N/A NLA V1-1201-030-H601 1987 REPLACEMENT I ' YES j POWER 1

7. Description of Work Snubber AD-151. seriel#154 was repfaced wifh snubber AD-151, serial #482 to support survdance festing.
8. Test Conducted: Hydrostatic ~neurmtic Nominal Operating Pressurea NIAB Other Pressure M A PSI Test Temp MA O F
9. Remarks See Item 7 Applicable Manufacturer's Data Repotts to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made i n the report are correct and this

- replacement conforms to the rules of tpe ASME Code, Sectbn XI. repair or replacement Type Code Symbol Stamp #/A N/A Team Leader II. the undersigned, holding a valid comnission CERTIFICATE OF INSERVICE INSPECTION issued by the national Board of Boiler and Pressure Vessel lnspactors and the State - or 1

Province of Geomia and employed by Hartlbrd Steam Boi/er lns~ectionand Insurance Co. of Conneclic~t d Harthrtla Conne #cut have Inspected the components described in this Owner's Report during the period - Januarv 04. 2005

&&-a> and state that t o the best of my knowledge and belief, the Owner has performed examinations and taken correcho measures described i n this Owmrs Report in accordance with the requirements of the ASME Code. Section ; XI.

I By signing this certlfme, nelther the Inspector nor his employer makes any warranty, expressedor hplled, concerning the examinations and ~0Vocthre measures described i n this Owners Report. Futthermore, neither the Inspector nor his employer shall be liable i n any mannehfor any personal injury or property demage or a loss of any kind arising from or connected wlth this Commissions &A a-National W r d . State.Province and Endorsements I

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provlsloqs Of The ASME Code $ectlon XI Tmvelerl 05004 cl

1. Owner Southem Nuclear Opemtlng Company Date W11/05 /

Name 40 lnvemess Center Padrway, Birmingham, AL Sheet 1 of 1 Address

2. Plant Vogtle Eiectric Generating Plant Unit 1 Name

~ a ~ n e s b o rGA o , 30830 WO# 10403140 Address Repair OrganlreUon P.O. No., Job No., etc.

3. Work Performed by Maintenance Department Type Coda Symbol Stamp WA Name Authorhtlon No. NLA Plant Vogtle Gcpiratlon Dam WA Address
4. Identification of System 1204 /Safety Injection System 1553-1 .
5. (a) Applicable Construction Code ASME SEC 111 1 9 7 4 Edition, Summer 1974 Addenda, 8 1649 Code Case (b)Applicable Edition of Sectlon XI Utillzed for Repairs or Replacements 1989
6. Identification 01 Components Repairedor Repleced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replad, Stamped Component Manufacturer Serial No. No. ldentlflcatlon BuiR or Replacement (Yea or NO)

VALVE WESTINGHOUSE 10001CS990000 W18317 1-1204-U6-079 1978 REPlACEMEM YES 00005740002

7. Description of Work Circular mounting pads (appmdmately 1' diameter and 11" thick) for acoustic sensors were f a b h t e d from SA-240 TP 304 plate and welded to the valve. One pad is located on the external-top-side of the valve oubt and the second is located on the external-bottom-side of the valve body. Installation of the mounting pads was completed in accordance with MDC 04-V1M055.
8. Test Conducted: Hydrostetic ~ n e u m a t i c n Nominal Operating ~ r e s s u r e n N I A ~ Other 0 Pressure WA PSI Test Temp. WA OF
9. Remarks See Item 7 Appllcable Manufacturer's Date Reports to be attached h

CERTIFICATE OF COMPLIANCE We certity that the stetements made in the report are correct end this replacement conforms to the rubs of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp WA Expiratlon Data

- Owner or Mner's Designee, Title Team Leader Date

--I - 7 CERTIFICATE OF INSERVICEINSPECTION I,the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the Stab or Provlnce of Geomia and employed by _ H e r H o r d m m of Hartfont. Connecticut have Inspected the components described in this Owner's Report during the period a to ,T- 1 1 - 6 5 , and state that to the best of my knowledge and belief, the Owner has performed examlnatlons and taken corrective measures described In this Owners Report In accordance with the requirements of the ASME Code,Section XI.

By signing this certlflcate, neither the Inspector nor hls employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor hls employer shall be Ilable In any manner for any personal injury or property damage or a loss of any kind arising from or connected wlth this Commissions Natlonal Board, State, Provlnw and Endorsements Date 5-/?-a5

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The ProvisionsOf The ASME Code Section XI Traveler # 05005 I /

1. Owner Southem Nuclear Operating Company Date 05/11/05 Y Name 40 lnvemess Center Parkway, Blrrningham, AL Sheet 1 ol 1 AddtBss
2. Plant Vogtle Electric Generating Plant Unit 1 Name Wayneslwro,GA 30830 WO# 10403140 Addresa Repair Organization P.O. No., Job No., etc.
3. Work Performed by Maintenance Department Type Code symbd Stamp Name Authoridon No. WA Plant Vogtle Expiration D m WA Address
4. Identificationof System 1204/Safety Injeciion System 1553-1
6. (a) Applicable ConstructionCode ASME SEC 111 1 9 2 Edition, Summer 1974 Addenda, 8 1649 Code Case (b)Appllcable Editlon of Section XI Utilized for Repairs or Replacements 1 9 a
6. ldentlficatlon Of Components Repaired or Replaced and ReplacementComponents Natlonal Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. ldentiflcation Elullt or Replacement (Yes or No)

VALVE WESTINGHOUSE 10001CS990000 W18388 1-1204-U6-080 1978 REPLACEMENT YES 0000s740004

7. Descrlptlon of Work Circular mounting pads (approximately 1' diameter and 16- thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the exiemal-topsideof the valve oulet and he second is located on the external-bottom-sideof the valve body. Installationof the mount in^ pads was completed in accordaI)C8 with MDC 04-VIM055.
8. Test Conducted: Hydrostatic ~ n e u m a t i c n Nominal Operating ~ r e s s u r e o N/AB other q Pressure WA PSI Test Temp. WA .F
9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements mede in the report are correct and this replacement conforms to the rules ol the ASME Code, W o n XI. repair or replacement

\ ,( Type Code Symbol Stamp N/A I CERTIFICATE OF INSERVICE INSPECTION 1, the underslgned, holdlng a valid commission issued by tho national Board of Boiler and Pressure Vessel Inspectors and the State or Province ol Geomia and employed by Hatiford Stea~ I of Q nn t m t have Inspected the components described in this Owner's Report during the period A 1

,*i and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance wlth the requiremanta of the ASME code^,Section XI.

By signing this certificate, nelther the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described i n this Owners Report. Furthermore, neither the Inspector nor h b employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arislng from or connected wlth this Commissions GAd&

Inspeci6r's Signature National Boerd. Stem, Province and Endorwrnenta Data 5-/7-65

. .., I ORIGINAL . ,

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions 01The ASME Code Section XI Traveler# 05006 4

1. Owner Southern Nuclear Operating Company Name Date

- 091 1/05 40 lnvemess Center Parkway, Blrrningham, AL Sheet 1 of 1 Address

2. Plant Vogtle Electric Genemting Plant Unit 1 Name Waynesbom, GA 30830 WO# 10403140 Address Repair Organlzstlon P.O. No., Job No.,etc.
3. Work Performed by Maintenance Department Type Code. Syrnbd Stamp WA Name AuthorizationNo. WA Plant Vogtle Gcplration Date WA Address
4. Identificationof System 1204 / Safety Injection System 1553-1
5. (a) Applicable Construction Code ASME SEC 111 1 9 7 4 Edition, Summer 1974 Addenda, 8 1649 Coda Caw (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19&
6. IdentificationOf Components R e p a i d or Replaced and ReplacementComponents National Repaired, ASME Coda Name of Name of Manufacturer Board Other Year Replacod, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

VALVE WESTINGHOUSE 10MllCS990000 W18389 1-1204-U6-081 1978 REPLACEMENT YES OWOS740005

7. Descriptionof Work Circuler mounting pads (approximate& 1" dismeter and %"thick)for acoustic sensors wen, fabricated from SA-2.40 TP 304plate and welded to the valve. One pad is located on the external-top-sida of the valve oulet and the second is located on the external-bottom-sideof the valve body. lnstallation of the mounting pads was completed in accordance with MDC 04-V1M055.
8. Test Conducted: Hydrostatlc ~ n e u m a t l c O Nominal Operating ~ r e a s u r e n N I A ~ Other Pressure W A PSI Test Temp. MA OF
9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, m i o n XI. repalr or replacement Type Code Symbol Stamp WA WA Expiration Date WA Team Leader

- Owner downer's Desi$nw, Title CERTIFICATE OF INSERVICE INSPECTlON I,the undersigned, holdlng a valid commlsslon issued by the national Board of Boiler and Premure Vessel Inspectors and the State or Provlnce of Geomia and employed by Hartford Steam Boil r of Hartford. Connecticut have inspected the components described In this Owner's Report during the period 02/01MS to 5 - / 7 d S , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measurer described in thls Owners Report In accordance wlth the requlrements of the ASME Code.Section XI.

By slgnlng thls certlflcate, ndther h Inspector nor hls employer makes any warranty, expressed or Implled, concerning the examlnatlons and corrective measurea described In this Owners Repoh Furthermore, neither the lnrpector nor his employer shell bellable In any manner tor any personal lnlury or property damage or a loss of any kind arislng from or connected with this Commissions G !a03 National Board, Stab, Province and Endormmenb C

Daet-

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code S F i o n XI

. . . Traveler# 05007 4

1. Owner Southem Nuclear Operating Company Date 05/l1&5 Name 40 lnvemess Center Parkway, Blrmlngham. AL Sheet 1 of 1 Addrew
2. Plant Vogtle Electric Generating Plant Untt 1 Name Waynesbotu, GA 30830 WO# 10403140 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by Maintenance Department Typn Code Symbol Stamp WA Name Authorlzn~lon No. WA Plant Vogtle Expiration Data WA Address
4. IdentHlcationof System 1204 /Safely In]ection System 1553-1
5. (a) Applicable ConstructionCoda ASME SEC 111 1 9 7 4 Edition, Summer 1974 Addenda, 8 1649 Code Caw (b)Applicable Editlon of Section Xi Utilized for Repairs or Replacements lS@
6. IdentificationOf Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement . (Yes or No)

VALVE WESTINGHOUSE 100alCS990000 W18316 1- 1204-U6082 7978 REPLACEMENT YES 00005740001

7. Descriptlon of Work Circular mounting pads (approximately 1" diameter and Y " thick) for acoustlc sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the external-top-side of the valve oulet and the second is located on the external-bottom-side of the valve body. Installation d the mounting pads was completed in accordance wlih MDC 04-V7M055.
8. Test Conductsd: Hydrostatic ~neumatic[7 Nominal Operating ~ r e s s u r e m NIA~ other pressure WA PSI ~ e s~emp.

t WA OF

9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be atlached

- CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thls replacement conforms to the rules of the ASME Code, Sectlon XI. repair or replacament Type Code Symbol Stamp WA

\

, ( Certiflcete of Aythorization No. - / WA Expiration Date WA Team Leader Owner wner's Designee, Title -,

CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geomia and empioyed by - & & & & g @ @ of

_Hartford. haw inspected the components described in this Owner's Report during the period 02/01/05 to 5 - i 7 - d < and state that to the best of my knowledge and bellef, the Owner has performed examinations and taken corrective measures described in this Owners Rbport in accordance wlth the requirements of tho ASME Code, Section Xi.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examlnetions and corrective measures described in this Owners Report. Furthermore. neither the inspector nor his empioysr shall be liable In any manner for m y personal injury or property damage or a loss of any kind arbing from or connected with this Commissions add3 National Board. State, Province and Endorsements Date .q- /7&

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Sectlon XI

1. Owner Southem Nuclear Opemtlng Company Date Traveler#

0 9 1 1/05 05008 r

I Name 40 lnvemess Center Parkway, Birmingham, AL Sheet 1 of 1 Address

2. Plant Voglle Electric Generating Plant Unlt 1 Name Waynesboro, GA 30830 W& 10403140 Address Repair Organlzetlon P.O. No., Job No., etc.

Work Performed by Maintenance Department ~ype code Symbol Stamp NLA Name AuthorizaUon No. WA Plant VogtIe ExpirallonData NLA Address Identificationof System 3204 /Safety Injection System 1553-1

5. (a) Appllceble Construction Code ASME SEC 111 1974 Edltlon, Summer 1974 Addenda, & 1649 Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacementa l9a
6. ldentlficetion Of Components Repaired or Replaced end Replacement Components National Repaired, ASME Code Name of Name of Manufecturer Board Other Year Repla, stamped Component Manufacturer Serial No. No. Identification Built or Replecement (Yes or No)

VALVE WESTlNGHOUSE 10001CS990000 W18390 1-1204-U6-083 1978 REPLACEMENT YES 00005740006

7. Description of Work Circular mounting pads (approximately 1' diameter and %" thick) lor acoustic sensors were fab~catedfrom SA-240 TP 304 plate and welded to the valve. One pad is located on the extemal-fop-sideof the valve oulef and the second is located on the external-bottom-side of the valve body. Installation of the mounting pads was completed in accordance with MDC 04-V1M055.
8. Test Conducted: Hydrostatic q pneumatic0 Nominal Operating ~ r c a s u r e a NIAO Other q Pressure N/A PSI Test Temp. N/A OF
9. Remerks See Item 7 Applicable Manufacturer's Data Reports to be anached CERTIFICATE OF COMPLIANCE We certlfy that the statementa made In the report are correct and this replacement conforms to the rules of the ASME Code.Section XI. repeir or replacement Type Code Symbol Stamp MA CERTIFICATE OF INSERVICEINSPECTION I,the undersigned, holding e valid commission Issued by the natlonel Board of Boiler and Pressure Veasel Inepectors and the State or Province of Geomia and employed by H e r t f o r d a of H a M d . Connect&ut have in+W the components descrIbd In this Owner's Report during the period 02/01/05 to 7 ,and state that to the beet of my knowledge and belief, the Owner hes performed examinations and taken

~ r r e c t i v emeasures describd In this Owners Report in accordance with the requlrementa of the ASME Code,Section XI.

By signing this certlticuto, neither the Inspector nor his employer makes any warrenty. expressed or implkd, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employsr shdl a1 Injury or property demage or a loss 01 any kind arising lrom or connected wlth thls Commissions a a3 National Board, State, Provlnce and Endorsements ate 5-17-45'

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler W 05009

1. Owner Southem Nuclear Operating Company Date OVl1DS I Name 40 lnvemess Center Parkway, Bimingham, AL Sheet 1 of 1 Address
2. Plant Vogtle Electric Generating Plsnt Unit 1 Name Waynesborv, GA 30830 WOAY 10403140 Address Repair Organlzetion P.O. No., Job No., stc.
3. Work Performedby Maintenance Department Type Code Symbol Stamp WA Name Authorization NO. WA Planf V a l e Expiration Date WA Address
4. Identificationof System 1204 /Safely lnlectlon System 1553- 1
5. (a) Applicable Construction Code ASME SEC 111 1 9 7 4 Edition, Summer 1974 Addenda, 8 1649 Code Case (b)Appllcable Edltion of Section XI Utilized for Repairs or Replacements 1989
6. IdentificationOf Components Repairedor Replaced and Replacement Components National Repaid, ASME C&

Name of Name ot Manufacturer Board Other Yeer Replaced, Stamped Component Manufacturer Serial No. No. ldentitlcation Built or Replacement (Yes or No)

VALVE WESTINGHOUSE 10001CS990000 W18318 1-1204-U6-084 1978 REPLACEMENT YES 00005740003

7. Description ot Work Circular mounting pads (appmximately l'diameter and 14" thick) for acoustk sensors were fabriceted fmm SA-240
8. Test Conducted: Hydrostatic ~ n e u m a t i c O Nominal Operating ~ r e s s u r e O WAN Other Pressure NLA PSI Test Temp. ' N/A S B. Remarks See Item 7 Appllcabk Menufecturer's Data Reports to be etbxhad CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thls mplacement conforma to the rules of the ASME Code, Sectlon XI. repair or replacement Type Code Symbol Stamp N/A Expiration Date MA Team Leader Date CERTIFICATE OF INSERVICEINSPECTION I, the underalgned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspecton, and the Smte or Province of Geomia and employed by Harfford Steam Boiler Insoection and In-umnce Co. of Connecticut of Hatiford. Connecticut have Inspected the components described in this Owner's Report during the perlod 02/011Y)5 to 5 - 1 7 - S , and state that to h best of my knowledge and belief, the Owner has pertormed exsminstlons end taken corrective measures described in this Owners Report in accordance wlth the requirements ot the ASME Code,Section XI.

By signing t h b certificate, neither the inspector nor his employer makes any warranty, expmasad or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his emplopr ahall proparty damage or a loss of any kind arising from or connected wlth this Commisaiona GA -3 Natlonai Board, State, Province and Endorsements Date Sw-/f-d

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The ProvisionsOf The ASME Code Section XI

1. Owner Southern Nuclear Operating Company Date Traveler t 091 1/05 050 10 7

Name 40 lnvemess Center Parkway, Birmingham, AL Sheet 1 of 1 Address

2. Plant VogNe Electric Generating Plant Unit 1 Name Waynesbom, GA 30830 WO# 10403140 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by . Maintenance Department Type Code Symbol Sump N/A .

Name Authorization No. NLA Plant Vogtle Expiration Date NLA Addreas

4. Identificationof System 1204 /Safety Injection System 1553- 1
5. (a) Applicable Construction Coda ASME SEC 111 1 9 7 4 Edition, Summer 1974 Addenda, & 1649 Code Caw (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification Ol Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. ldentificatlon Built or Replacement (Yes or No)

VALVE WESTINGHOUSE 10001CS99OOW W17476 -

1 1204-U6-085 1978 REPLACEMENT YES 0000s74ooaB

7. Description of Work Cin:uIar mounting pads (appmximately 1" diameter and %' thick) tor acoustic sensors were fabricated fmm SA-240 TP 304 plate and welded to the valve. One pad is located on the exfemaktopside of the valve oulet and the second is located on the external-bottom-sideof the valve body. Installation of the mounting pads was completed in accordance with MDC 04-VIMOSS.
8. Test Conducted: Hydrostatic ~ n e u m a t i c O Nominal Operating ~ r e s s u r e O W A ~ 0 t h q pressure MA PSI l e s t femp. WA OF
9. Remarke See Item 7 Applicable Manufacturer's Data Reports to be^ attached

- CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A WA Expiration Date WA Owner or Owner's Designee, Title Data -$;/Lcu~

CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission iaeued by the national Board of Boiler and Pressure Verurel Inspectors and the State or Province of Gsorpia and employed by Hanford Steam Boiler Insmction and lnsunrnce Co. of Connecticut of H a r t l o r d . L have Inspected the components described In this Owner's Report during the period Oml/OS to a - / 7 - 6 5 , and state that to the best of my knowledge and belief, the Owner has pedormed exemlnations and taken corrsctlve measures described In thls Owners Report in accordance with the requirements of the ASME Code. W o n XI.

I By signing thls certlficete, neither the inspector nor his employer makes any warranty, expressed or impiied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be iiabie in any manner tor any personal injury or property damage or a loss of any kind arising hom or c o n n k t d with this Commissions 283 I

National Board, State, Province and Endorsements Date 5-17-a5 I

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler# 05011 Ll 1 Owner Southem Nuclear Operating Company Date 054 7/05 /

Name 40 lnvemess Center Parkway. Birmingham. AL Sheet 1 of 1 Address

2. Plant Voglle Electric Generatlng Plant Unit 1 Name Waynesbom, GA 30830 WO# 10403140 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by Maintenance Department Type Code Symbol Stamp WA Name AulhorlzeUon No. WA Plant Vogtle Expiralion Date WA Address
4. Identificationof System 1204 /Safety Injection System
5. (a) Applicable Construction Code ASME SEC 111 i 9 7 4 Edition, Summer 1974 Addenda, & 1649 . Code Case (b)Applicable Edition of Section XI Uti1ized for Repairs or Replacements 1989
6. ldentlfication Of Components Repaired or Replaced and Replacement Components National Repaired. ASME Code Name d Name of Manufacturer Board Other Year Repiad, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

VALVE WESTINGHOUSE 10001CS990000 W18391 -

1 12W-U6-086 1978 REPLACEMENT YES 0000s740007

7. Description ot Work Circular mounting pads (appmximately 1' diameter and I&" thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the external-top-side of the valve wlef and the second is located on the external-bottom-sideof the valve body. Installation of the mounting pads was wmpleted h accordance with MDC 04-V1M055.
8. Teat Conducted: Hydrostatic ~ n e u m a t l c m Nominal Operating ~ r e s s u r e 0 WAN Other 0 Pressure WA PSI Test Temp. WA OF
9. Remarks See Item 7 Appiicabie Manufacturer's Data Reports to be attached CERTIFICATEOF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, W o n Xi. repair or replacement Type Cock Symbol Stamp WA

- WA Expiration Date WA Team Leader Date OwneptG Owner's Designee, Title b

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commiaslon issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geomia and employed by a m Boiler Insmction and Insurance Co,of Connecticut of Harffom'. Connecticut have inspected the components described in this Owner's Report during the perlod - 0ZG1/05 to /-/7dF ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his empioyer makes any warranty, expreasd or impiled, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor hie cwnploysr shall be llable In any manner tor any personal injury or property damage or a loas of any kind arlslng from or connected with thls Commissions GAa 3 National Board, State, Province and Endorsements Date &--/765

FO.RM NIS-2 OWNEa b k b k % k 3 S OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Trader# 05012

1. Owner Southem Nuclear Operating Company . Date Apn?4, 2005 Nanm 40 lnvemess Center P a m a y , Bimngham. AL Sheet 1 of 1 Address
2. Plant Vogue Electric Generating Plent Unit 1 Name Waynesboro. GA 30830 1040319601 Address Repair Organization P.O. No., Job No., etc.
3. Work P e r f o w by Maintenance Department Type Code Symbol Stamp WA Name Authorlzatlon No. WA Rant Vog& Explratlon Date WA Address
4. Identification of System 1204/ SaBly Injection System
6. (a) Applicable Construction Code ASME SEC 111 19 77 Editin. Wnfer 1977 Addenda, WA Code Case (b)Applkable Edition of Section XI Utilized for Repairs or Replacements 19@
6. ldentification Of Components Repaired or Replaced and ReplacementComponents National Repaired. ASME Code Name of Name of Manufacturer Board Other Year Replaced, stamped Component Manufacturer Serial No. No. identification Built or Replacement (Yes or No)

PIPE SUPPORT PULLMAN. N/A NLA ' V1-1204021-HOlO 1987 RERACEMENT YES POWER

7. Description of Work Replace pipe support 1-1204021-H019 b suppo~MDC OCVlM033
8. Test Conducted: Hydrostatic ~ n e u m a t i c n Nominal Operating ~ r e s s u r e m NIA Other [g ' Pressure M A PSI Test Temp. N/A OF
9. Remaas Seeltem 7 Applicable Manufacturer's Data Reports to be attachad CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of tlr ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A N/A ~x~irati& Date l MA Teem Leader Date or Owner's Desi$nee. Tltle CERTIFICATE OF INSERVICE INSPECTION I,the undersigned. holding a valid commission issued by the national Board of Boikr and Pressure Vessel I n m o m and the State or Province of Georuia and employed?by drof t raH of Harthd.

Connecaut have inspected the components described in this Owner's Report during the perkd - February 3. 2005 t o 7 - L -& ,and state that t o the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described i n this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, elipressed or implied, concerning the examlnatlons and corrective measures descrikd i n , this. Owners Report. Furthermore, neither the lnsptxtor nor his employer shall for any personal injury or property damage or a loss of any kind arlsing from or connected with this Commissions National Board, State. Province and Endorsements Date 7 4 I

FORM NIS-2 OWNER'S As Required By The Provisions Of The ASME Code Section XI Tmveler# 05075 4 Owner Southern Nuclear Operabhg Company Date A@ 29.2005 Name 40 lnvemess Center Parkway, Birmingham. AL Sheet 7 of :1 Address Plant Voglle Electric GeneratingBent Unit ' 7 Name Waynesbom, GA 30830.- 10201413 Address Repair Organization P.0. No., Job No.. etc.

W m Performed by MaintenanceDepartment Type Code Symbol Stamp N/A Name AuthorlzatlonNo. N/A Pbnt Vogue Expiration Date WA Address Identifmtion of System 1201/Reactor Coolant System (a) Applicable Construction Code ASME SEC 111 1 9 7 1 Edition, Summer 1972 Addenda, N-4Sl Code Case (b)ApplicaMe Edition of Section XI Utllized for Repairs or Replacements 1889 Identification Of Components Repaired or Replaced and ReplacementComponents National Repaired, ASME Code Name of Name of Manutacturer Board Other Year Replaced. Stamped .

Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

STEAM WESTINGHOUSE GAGT 1884 NIA 1-1201-86-004 1981 . REPLACEMENT YES GENERATOR ELECTRIC CORP.

7. Description of Work Instalreplacement threaded hdcal-coilinsert and replacementbolt on cold leg inspection port handhab (Ul-SGQCUPH), b ~ lhde f #3.
8. Test Conducted: Hydrostatic (g ~ n e u m a t i i a Nominal Operating ~ r e s s u r e a NIAa. Other Pressure N/A PSI Test Temp. N/A OF
9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify thal the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement 1 Type Code Symbol Stamp N/A I Expiration Date

-/ 1 WA I

Team Leeder Oat

, , I C . I CERTIFICATE OF INSERVICE INSPECTION ' 1 I, the undersigned, holding a valid commission issued by the national ~ o a r d ' oBoilerf and Pressure Vessel Inspectors andstheState or Province of Geomia and employed by Hu~ifordSteam Boiler Ins~ectionand Insurance Co. d Conneciicut of Connec8cuf have inspected the components described i n this Owner's Report during the period M a r ' 8. 2005 to a, and state that t o the best of my knowledge and be~lhf,the Owner has performed examinations and taken corrective measures described in thls Ormcrs Report I n accordance wlth the requirements of the ASME Code,Section XI.

By signing this certificate, nelther the Inspector nor his employer makes any warranty, expressed or implled. concerning the examinations and corrective measures described In thls Owners Report. Furthermore, nelther the Inspector nor his amployer shall rsonal injury or property damage or a loss of any kind arising from or c o d & d t h this Commissions GA30 1 National Board, State. Provlnce and Endorsements Date 5 05'

FORM NIS-2 OWNER'S R M L N L S o R wmcE,Ews As Required By The Provisions Of The ASME Code Section XI Traveler # 05016 1 Owner , Southem Nuclear Operating Compeny Date Aprir 15.2005 I Name 40 lnvemess Center Parkway. Birmingham. AL Sheet 1 of 1 Address

2. Plant Vogue Electric Generating Plant Unit 1 Name Waynesbotu. GA 30830 10201414 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by Maintenance Depertment Type Code Symbol Stamp WA Name Authorlzatlon No. WA Plant Vogfle Explratlon Date WA Address
4. Identification of System 7201 /Reactor Codant System I
6. (a) Applicable Construction Code ASME SEC 111 1 9 2 Edition, Summer 1972 Addenda, N-4961 Code ~ a i e I

(b)Appiicable Edition of Section Xi Utliized for Repairs or Replacements 19Bg

8. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, stamped:

Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

STEAM WESTINGHOUSE GAGT 1881 NLA I-1201-B6-001 1981 REPLACEMENT YES '

GENERATOR ELECTRIC CORP.

7. Description of Work Instal meplacement threaded helical-coi insert end replacement bolt on cold leg inspeclion port handhde (Ul-SGl-CUPH), bbdl hole t i .
8. Testconducted: Hydrostatic Pneumatic 1 Nominal Operating ~ r e s s u r e m N I A ~ ' other Pressure N/A PSI Test Temp. MA OF
9. Remarks Seeltem 7 Applicable Manufacturer's Data Reports to be attached I

CERTNICATE OF COMPLIANCE We certify that the statements made i n the report are correct and this meplacement conforms to the rules oft?

ASME Code,Section XI. repair or replacement Type Code Symbol stamp N/A Certificate of Authorizatkn No. A NLA Expiration Date NLA Spned &&&f er ner' ignee, Title Team Leader I CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued b y the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geomia and employed by Harllbtti S t e e of Ha#btd.

have ~nspectedthe components described i n this Owner's Repatt during the period - March 8. 2005

- ,and state that to the best of my knowledge and belief, the Owner has performed examinationsand taken corrective measures described i n this Owmrs Report i n accordance with the requirements of the ASME Code, Saction ;XI.

By signlng this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concemlng the examinatkns n this Owners Report. Furthennore, neither me Inspector nor hls employer +all nal injury or property damage or a loss of any kind arislng from or conmcted with p i s Commissions GA 30.3 National Board, State. Province and Endorseme& ,

1 a .

FORM NIS-2 OWNER'S M i W b d & R REPUCEMENTS As Required By 'The Provlskns Of The ASME Code Section XI Traveler# 05017 4

1. Owner Southern Nuclear Operating Company Date Apn? 18.2005

. i Name 40 lnverness Center Parkway. Birmingham, AL Sheet 1 of 1 Address

2. Plant VogUe Electric Generating Plent Unit 1 Name Waynesboro. GA 30830 1050495601 Address Repair Organization P.O. No.. Job No.. etc.

Work Performed by Maintenance Depafiment Type Code Symbol Stamp WA Name Authortzatlon No. WA Plant Vogfle Expiretlon Date WA Address Identification of System 1205 /Residual Heat Removal System

6. (a) Applicable Construction Code ASME SEC 111 1 9 7 7 Edition, Wnter 1977 Addenda, WA Code Case (b)Applkable Edition of Section XI Utilized for Repalrs or Replacements l o @
6. Identif~ation 01 Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Repkd, Stamped Component Manufacturer Serial No. No. ldentlfication Built or Replacement (Yes or No)

VALVE FISHER WA WA 1FV-0619 1980 REPLACEMENT YES :

I

7. Description of Work Replace stud end nut due to bomn reddue in gasket area.
8. Test Conducted: Hydrostatic ~neumtk Nomlnal Operating ~ r e s s u r e a N I A ~ . Other Pressure WA PSI Test Temp. WA T
9. Remarks See #em 7 Applicable Manufacturer's Data Reports to be attached . ,

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conform to the rules of the ASME Code.Section XI. repair or repLacmnt Type Code Symbol Stamp WA WA Expiration Date WA Team Leader Date Owner I CERTIFICATE OF INSERVICE INSPECTION I.the undersigned. holding a valid commission issued by the national Board of W l e r and Pressure Vessel Inspectors and the State or Province of Geonrria and employed by H a t i f o m of &&&&

to .q-36$ .

C o n n e M have inspected the components described i n this Owner's Report during the period -Match 14. 2005 and date that to the b e d of my knowbdge and belief. the Owner has p e r f o r d exadnatlons and taKen care@vie measures described i n this Owners Report In accordance with the requirements of the ASME Code, Section' XI.

By signing this certificate. neither the Inspector nor his employer makes any warranty. expressed or implied. concerning the examinations rs Report. Furthermore, neither the Inspector nor hfs employer fihall property damage or a loss of any kind arlslng from or connected with this Commissions c-3 NationalB6ard. State, Province and Endorsements Date 5-3-aF

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi Traveler # 0501 8 Owner Southern Nuclear Operating Company Date May 16,2005 Name 40 lnvemess Center Parkway, Birmingham. AL Sheet 1 of 1 Address Plant VogUe Electric Generating Rant Unit 1 Name Waynesbom, GA 30830 10515086 Address Repair OrganizationP.O. No., Job No., etc.

Work Performed by Melntenance Department Type Code Symbol Stamp WA Name Authorltstlon No. WA Pknt V q rae

' ExplratlonDate WA Address Identife&~onof System 1301 / Main Steam System (a) Applicable Construction Code . ASME SEC 111 1 9 7 7 Edition, Winter 1077 Addenda, WA Code Case (b)Appliable Edition of Section XI Utilized for Repdrs or Replocamants I@@

Identifcation Of components Repaired or Replaced and Replacement Components Natiii Repaired. ASME Code Name of Name of Manufacturer Board Other Year Replaced. Stamped Component Manufacturer Serial No. No. Identification Bulk or Replacement (Yes or No)

SAFETY VALVE CROSBY MA N/A 1-PSV-3021 1979 REPLACEMENT YES

7. Description of Work Installed repl~cementvalve. TNs replacement valve is a mtating spare. orginadry instahd during constmfhn In location 1-PSV-3031.
8. Test Conducted: Hydrostatic ~ n e u m a t k a Nominal Operating pressure@

NIAD Other a Pressure N/A PSI Test Temp. N/A T S. Remarks Seelfem 7 Appilcable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made i n the report are correct and this replacement conforms to the rules of the ASME Code. Scctlon XI. repair or replacement Type Code Symbol Stamp WA

/ N/A Expiration Date N/A Team Leader hte c/t</idF Owndor Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I I,the undersigned, holding a valid c m i s s i o n issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geon?ie and employed by H a m r d d of UaCo.nl, Connecticut have inspected the components described In this Owner's Report during the perlod Match 15. 2005 to 17-6< ,and State that to the bed of my knowledge and belief, Me Owmr has performed examinations and taken corrective measures described in this Owners Report in accordance with Me requirements d the ASME Code,Section XI.

By slgnlng this certlfiite. neither thc Inspector nor his ampioyer makes any warranty, expressed or .mplied, concerning the examinations and corrective measures described in this Owners Report. Furthemre, neither the inspector nor his empbyer shall property damagc or a loss of any kind arising from or connected wlth this Commissions 3 Natlonal Board. State, Province and Endorsements Date ,377-176 I

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler W 05022

' q

1. Owner Southern Nuclear Opemting Company Date 04M2H)5 I Name 40 lnvemess Center Parkway, Birmingham, AL Sheet 1 ot 1 Address
2. Plant Vogte Electn'c Generating Plant Unit 1 Name Waynesboro,GA 30830 WOU 10403740 Address Repair Organhation P.O. No., Job No., etc.
3. Work Performed by Maintenance Department Type Code Symbol Stamp WA Name Authorbetion No. nv!'

Plant Vogtle Expiration Dab WA Address

4. Identification of System 1201 /Reactor Coolant System
5. (a) Applicable Construction Code ASME SEC 111 1Q Edition, n Winter 1977 Addenda, N-2441 Code Case (b)Applicable Edition of Section XI Utilizedfor Repairs or Replacements 19M
6. Identification Of Components Repaired or Replaced and ReplacementComponents Netional Repaired, ASME Code Name of Name of Manufacturer Bollrd Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

PIPE PULLMAN POWER NIA UIA V1-1201-03O.HW9 1987 REPLACEMENT YES :

SUPPORT RODUCTS

7. Descriptlon of Work Snubber AD-501, .Sehl#364 was replaced with an AD-501 serlal#552 to support su~~illance testing.
8. Test Conducted: Hydrostatic PneumatlcO Nominal Operating ~ r e s s u r e O NlAO Other Pressure WA PSI Test Temp. WA .F
9. Remarks Seeltem 7 Applicable Manufacturer's Date Reportsto be attached I

CERTIFICATEOF COMPLIANCE We certifythat the statements made in the report are correct and this replacement conforms to the rules of @e ASHE Code, Sectlon XI. repair or replacement Type Code Symbol Stamp WA CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holdlng a valid commis8ion Issued by the national Board of Boller and Pressure Veawl Inspecton, and the State or Province of and employed by Hartford Steam Boiler I~SmCtiOnand Insurance Co. of Conneciicui of

  • %ep-, have Inspected the components described In thls Owner's Report during the p l o d and sLek that to the best of my knowledge and belled, the Owner has performed examlndons and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Coda, Section, XI.

~ 7 / w I By slgning thls certlflcate, nelther the Inspector nor his employer makes any warranty, expressed or implied, concerning 'the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employsr shall be llable In any manwr tor any personal Injury or property damage or a loss of any klnd arislng from or connected with *la omm miss tons G&a-3 I

National Board, Sbte, Provlnce and Endorwmenta

ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Requlred By The Provisions Of The ASME Code Section XI Traveler(l 05024

b 7-
1. Owner Southem Nuclear Operating Company Date 04/2W05 Name 40 lnvemess Center Parkway, Birmingham, AL Sheet 1 of 3 I

Addreaa

2. Plant Vogtle Electric Generating Plant UnM 1 Name Waynesbom, GA 30830 WO# 10515569 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by Maintenance Department Type Coda Symbol Stamp N/A Name Authorhtlon No. WA Plant Vogtle Expiratlon Data NA Addrbsa
4. Identificationot System 1208 / Chemlcal and Volume Control System
5. (a) Applicable Construction Code ASME SEC 111 1 9 7 4 Edition, WA Addenda, 1637 Codecaw (b)Appllcable Edition of Section XI Utilized for Repairs or Replacementa 19& I
6. IdentificationOf Components Repaired or Repleced and Replacement Components National Repaired, ASME Coda Name of Name of Manutacturer Board Other Year Replaced, stern&

Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or Nb)

VALVE FISHER 6499541 3240 1HV8149C 1978 REPLACEMENT YES I CONTROLS CO. tI I

7. Description d Work Valve plug /stem assembly was replaced. A copy of Fom N-2 for the replacement plug send numberAG2446-1 is attached.
8. Test Conducted: Hydroatatic ~ n e u m a t i c a Nominal Operating ~ r e a e u r e u NIAB Other q Preaaure WA PSI Teat Temp. WA OF
9. Remarks See Item 7 Applicable Manufacturer's Data Reporta to be attached CERTIFICATE OF COMPLIANCE I We certify that the statements made in the report am correct and this replacement conforms to the rules d the ASME Code.Section XI. repalr or replacement Type Cock Symbol Stamp WA EUA Expiration Date EUA Team Leader Date I CERTIFICATE OF INSERVICE INSPECNON 1 I, the undersigned, holding a valid cornmisalon iaeued by the national Board of Boiler and Preaaure Vessel Inspectors and the or Province ot Geomk and employed by _HertfoJd-d-n$urance Co. of Connecticut of have Inspected the components described in this Owner's Report during the period  :

to &./-&C ,and state that to.the best of my knowledge and bellof, the Owner ha8 performed examinstions and ?ken corrective measures deecribed in this Ownera Report in accordance with the requirements of the ASME Code, Section; XI.

I By signing this certlflcate, neither the inspector nor his employer makes any warranty, e x p m w d or implied, concerning,the examinations and corrective measures described in thia Ownera Report. Furthermore, neither the inspector nor his employer :hall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected wlth ,this I

II ins t Commissions fldad inspect a Signature National Board, State, Province and Endorsemanta Data ;T-.J-r\l

I

T r a ~ e b r 405024 FORM N-2 CERTIFICATE BOLDERS' DATA REPORT FOR IDENTICAL she& 2 04 3 NUCLEAR PARTS AND APPURTENANCES*

As Required by tbe Providons oltbe ASME Code, Section IlI I

Not to exceed One DaypaProductio~

Pg- 1 of 1

1. M-anddIsdb FISHER COWR0L.S LN7"L MC., 205 SOUTH CENlR STREET, MARSHALL'TOWN. I A SOLS8 (nrmc i d d N P T Mia& Hok)

COMROL SOUTHERN.NUCLEAR PLAHIS,3850 IAJWWLDDR. ! W W m OA, 30024

(-.ad*d*)

3. L o c ~ o f ~ l . L i m VOGRZ ELECTRIC GEN. KT.,7811 RIVER RD.,WAYNESBORO, GA, 30830

(-.nd.dctou) I

4. Trpc 21AE982 RBV. B SA479 S316W 75 K81 NIA 2000 (dm* m.1 (rms'l. m.)

~pcr. (mik mgth) (CRN) (yarbuill) :

6. F.bricoiobinaewrdrocr*ritbw Spcc(Div.2ady) N/A Rcviim NIA IhU NIA  ;

(-1

7. Remulo: DESIGN: ASME BBtWC, IIl,1914 EDITION, NO ADDEND4 CLASS I 1

a N a n ~ c k n Cai ) NIA ~ i &h& dddrnae(h.) N/A Dir ID (tt Bbr) WA -a*.na(n&Sr) WA

10. Desi@l R6alr~ UBS pd. ragr 6% 1. HydFo.Mpteovc NIA T (when rppliable)

FORM K-2 (bYck) Tr~ueie re 05024-sheet 3 0 C 3 Mb. SaLl Nc. A 0 2 4 4 6 101 I Dtsign rpecircuti~ccmficdby HENRY P. LEONARD Cwkn rgplimbk)

P.E.State PA Rg. no. 23938-E  :

h W Ccd*nrc d ArnhorhJim No. 1930 EJ+- 11-1 1-2001

[hlc 9-7 4 0 Nme FISHER colUlROW IKT'LTNC (NPTk M i Hdds)

L U l c r u d a ~ b @ ~ d i n g ~ n l i d ~ ~ i a a n a r c d b y 6 r N a i ~ t ~ d b e o i l a d P l a e ~ V ~ L u p a p n u d ( h r ~ o r ~IOWAol dd d b . WllRTFOaD S 3 . L & I. m 7-00 s+d (Nd'L Bd.( i dmdammmm)m a yav.ad no.) I

2 ORIGINAL

' / -FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Ae Required By The Provisions Of The ASME Code Section XI Tmveler # 05025 I r

1. Owner Southem Nuclear Opemling Company Date 091m5 I Name 40 lnvemess Center Parkway, Birmingham, AL Sheet 1 of 1 Addreee 1
2. Plant Vogtle Electric Genemting Plant Unit 1 I Name I Waynesboro, GA 30830 WO# 10401555  !

Address Repair Organization P.O. No., Job No., etc.

3. Work Petiormed by Maintenance Department Type Code Symbol Stamp MA Name AuthorizelionNo. WA I Plant Vogtle ExpirationDate NIA t Addreas  !
4. ldentification of System 1201 /Reactor Coolant System I
5. (a) Applicable Construction Code ASME SEC 111 1971 Edition, Summer 1872 Adhnda, MA code ~ a *

(b)Applicabb Edition of Section XI Utllized for Repalre or Replacementa lQ& I

6. identification Of Components Repaired or Replaced and Replacement Components I Nameof I Nameof I Manufacturer I National Board I Other Repaired, VESSEL ENGINEERING, I INC. I I

i

7. Description of Work Replaced male flange on reactor vessel, penetration #78, thennocouple instwment port column assembly. I
8. Test Conducted: Hydrostatic ~ n e u m a t l c O Nominal Operating ~ r e s s u r e ~

NIAO Other Pressure M A PSI Teat Temp. MA OF

9. Remarks See Item 7 Applicable Manufacturer's Data Reporb to be attached 1 CERTIFICATE OF COMPLIANCE We certlfy that the statements m e in the report are correct and this replacement conforms to the rules of !he ASME Code.Section XI. repair or replacement I Type Code Symbol Stamp MA i Certificate ol uthoriution No. , MA MA i Team Leader Date 0 r or Owner's De ignee, Title I

1 CERTIFICATE OF INSERVICE INSPECTION 1 I I, the undersigned, holding a valid commission issued by the natlonai Board of Boiler and Preeeure Vraeel Inepectora and the dtata or Province of Geomia and employed by Hartford Steam Boiler lnsoeclion and Insurance Co.of Connecticut : of to Hadford. Connecticut have inepected the components described In this Owner's Report during the period 4-16-85 and state that to the beat of my knowledge and belbf, the Owner has perlormod examinetione and tdken a

corrective measures b s t r i b e d In thie Ownere Report in accordance with the requiremanta of the ASME Code, ~ectionlXI.

I By signing thle certificate, neither the Inepeetor nor hie employer makes any warranty, expreesed or implied, concernlngjthe examinations and corrective meaeureo d m r i b e d In thie Owners Report. Furthermore, neither the inepector nor hie employer shall injury or property damage or e iocu, of any kind arising from or connettad with ithis Commlseions GA303  !

Inspector%Signature National Board, State, Province and Endonemanta  !

4

As Required By The Provisions Of The ASME Code Section XI Traveler# 05027 Owner Southern Nucleer Operaling Company Date Apn'r 8,2005 Name 40 lnverness Center Parkwey, Blnnlnghern. AL Sheet 1 01 1 Address Plant VogUe Electric Generating Plant Unit 1 Name Waynesboro. GA 30830 10515616 Address Repair Organization P.O. No., Job No., etc.

Work Perto- by Malntenence Department Type Code Symbol Stamp NIA Name . . Authorlzatlon No. NIA Plant VogUe Explratlon Date NIA Address ldentlfication of System 1204 / Sahty lnjecllon (a) Applicable Construction Code ASME'SEC 111 1 9 7 7 Edition. Mlinter 1977 Addenda, N/A Code Cay?

(b)Applicabk Edition of Section XI Utilized for Repairs or Replacements 1989 ldentificatlon Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Coik Name of Name of Manufacturer Board Other Year Replaced. stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

PIPE SUPPORT PULLMAN IWA MA 1-1204431-HOT5 1987 REPLACEMENT YES POWER t

7. Description of Work Snubber PSA-lL?, serial #I9923 was replaced with PSA-lL?. serlel #I9719 to support surveillance testing..

Test Conducted:

8.

NIA Other a Hydrostatic ~ n e u t n a t k a Nomlnal Operating ~ m s s u r e m Pressure N/A PSI Test Temp. N/A . T

8. Remarks See Item 7 Applicable Manufacturer's Data Reports t o be attached L

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the ruks of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Explratimn Date MA Team Leader Date II,the undersigned, M d i n g a valid cammisston CERTIFICATE OF INSERVICE INSPECTION 1 issued by the national Board of Boiler and Pressure Vessel l n s p e d ~ and ~ s the State or Province of Geomia and employed by Hartlord S t t of Ha@nl.

. Connecticut have inspected the components described In this Owner's Report durlng the period March 23. 2085 t o 4- 1 - ,and state that to the best of my knowledge and belief, the Owner has performed examlnatiins and taken corrective measures- described in tMs Owners Report In accordance with the requirements of the ASME Code,Section XI.

- I By signing this certlkate, neither the Inspector nor his employer makes any warranty. expressed or Implied, concerning the examinations and c o m c t i w measures describsd i n this. Owners Report. Furthermore, nelther the inspector nor his employer shall be liable In any macner for any personal 'inJury or property damage or a loss of any kind arising from or connected wlth this I I ma*--

ins .

In or's Signature Commissions G-x National b a r d , State, Province and Endorsements I

FORM NIS-2 OWNER'S REPORT FOR  : @MGA NTS i

1. Owner As Required By The Provisions Of The ASME Code Section Xi Southem Nuclear Operating Company Date Traveler #

May 11,2005 05029

5 I

Name 40 Invemess Center Parkway, Binnhrghem. AL Sheet 1 of 1 I

Address

2. Plant Vogt/e ElecMc Generating Plant Unlt 1 Name Waynesbom, GA 30830 10402418 i Address Repair Organization P.O. No., Job No.. etc. I Work Perfomred by Maintenance Deperiment Type Code Symbol Stamp WA Name Authorlzalbn No. WA  !

Plant Vogfb Expiration Date WA 1 Address  !

identifiation of System 1201 /Reactor Coolant System

6. (a) Applkabk Construction Code ASME SEC 111 1 S E Edition, Wnter 1977 Addenda, AMA code cake (b)Applkable Edition of Section Xi Utilized for Repairs or Replacements 1889 I I
8. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Co$e Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serlal No. No. identifition Bulll or Replacement (Yes or No)

STEAM WESTINGHOUSE GAGT 1881 N/A 1-1201-66-001 1981 REPLACEMENT YES GENERATOR I I

7. Description of Work Replace Steam Generator primary manway stud et 1ocabbn.HL14.

i i

8. Test Conducted: Hydrostatk ~ n e u r n a t i c m Nominal Operating ~ r e s s u r e m NIA Other Pressure M A PSI Test Temp. AMA Y I I
9. Remarks Seeltem 7 I Applicable Manufacturer's Data Reports to be attached I

CERTIFICATE OF COMPLIANCE .

We certify that the statements made in.the report are correct and this mpracement conforms to the rules of t+e ASME Code,Section Xi. repair or replacement I

Type Code Symbol Stamp MA I Expiration Date AMA Team Leader CERTlFiCATE OF INSERVICE INSPECTION I I,the undersigned, holding a valid commission issued by the national Board of Boiier and Pressure Vessel Inspectors and the State or Province of Georuia and employed by Hartford Steam Boiler Ins~ectionand lnsunnce Co. of Conneclicut of H a p r d ,

Connecficut h y e inspected the components described in this Owner's Repotl during the period March 25. 2005 to j - / k c - d s ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken cor+ive measures described in this Owners Report- in accordance with the requirements of thc ASME Code, Section : XI.

By signing this certificate, neither the inspector nor his empioyer makes any warranty, expressed or implied, concerning the e x a m i n a t ~ s and corrective measures described in this Owners Repoh Furthermore. neither the Inspector nor his employer shall er for any personal injury or property damage or a loss of any kind arising from or connected with ithis Commissions rd, State, Province and Endorsemmts

ORIGINAL FORM NISQ OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A As Required By The Provisions 01 The ASME Code Section XI t Traveler # 06071 I I

1. Owner Soufhem Nuclear Operating Company Dale 05/02/06 I I

Name 40 lnvemess Center Parkway, Birmingham, AL Sheet 1 of 1  !

Addresa 1

2. Plant Vogtle Electric Generating Piant Unlt 1 Name WO# 1049001002and PO# 7071578 1

Waynesboro. GA 30830 I Addreis Repair Organization P.O. No., Job No., etc.

3. Work Performed by Maintenance Department Type Code Symbol Stomp N/A  !

Name Authorbation NO. WA i Plant Vogtle Address ExpirationDab WA  !

4. Identificationof System 1201 /Reactor Coolant System 1 I
5. (a) Applicable ConstructionCode ASME SEC 111 1 9 2 Edltion, Summer 1972 Addenda, WA Cod. CS+

(b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 19&

I

6. IdentificationOf Components Repaired or Replaced and Repl8cement Componenb 1 National Repalred. ASME Code Name of Named Manufacturer Board Other Year Replad, stamped(

Component Manufacturer Serial No. No. identlflcatlon Built or Replacement (Yes or No)

REACTOR COMBUSTION 8971 21668 1-1201-V6-001 1976 REPLACEMENT YES i

.VESSEL ENGINEERING, INC. 1 I

7. Description of Work The male flange assembly on the instrument port column was replaced by a new design corn exil themwcouple I n o d e assembly (CETNA). The CETNA assembly was installed on vessel penetration 76 in accordance with DCP 1049001001. 1
8. Test Conducted: Hydrostatic ~ n e u m a t i c n Nominal Operating ~ r e s s u r e B NIAO Other Pressure WA PSI Te8tTmp. WA "F
9. Remerka Seeltem 7 1 Applicable Manufecturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certlfy that the statements made in the report are correct and thls replacement conforms to the rules of the I

ASME Code,Section XI.

Type Code Symbol Stamp repair or replacement WA II Certiflcate of Authorization No. WA Expiration Date WA 1 I

Signsd Team Leader Date D9 10 v /06 I I

/ /  !

I I CERTIFICATE OF INSERVICE INSPECTION 1 1

I,the undersigned, holding a valld commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the Stiate or Province of Geoma and employed by Hartford Steam Boiler Insoecifon and Insum1148 Co. of Connecticut 1 of

&Ifford, Connecticut have inspected the components described in this Owner's Report during the period W/18/06 A to S / U / ~ O = and state that to the bast of my knowledge and bslld, the Owner has performed examinallone and te*n c o d v e messures described in thla Owners R e p f l in accordance wlth the requirements of the ASME Code, Section Xi.

I I By signlng this certiflcate, neither the Inspactor nor hle employer m a h s any warranty, expreesed or implied, concerning examinations and corrective measures describsd in thls Owners RepoR Furthermore, neither the Inspector nor hls employer sh,ell bn llable in any manner lor any personal injury or properly damage or a loss of any kind arising from or connactbd with this I