NL-05-2061, Revision 1 of Unit 1 Cycle 13 Core Operating Limits Report

From kanterella
Jump to navigation Jump to search
Revision 1 of Unit 1 Cycle 13 Core Operating Limits Report
ML053250039
Person / Time
Site: Vogtle Southern Nuclear icon.png
Issue date: 11/18/2005
From: Grissette D
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-05-2061
Download: ML053250039 (23)


Text

Don E. Grissette Southern Nuclear Vice President Operating Company, Inc.

40 lnverness Center Parkway Post Office Box 1295 Birmingham, Alabama 35201 Tel 205.992.6474 Fax 205.992.0341 November 18, 2005 Energy to Serve Your World' Docket No.: 50-424 NL-05-206 1 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Vogtle Electric Generating Plant Revision 1 of Unit 1 Cycle 13 Core Operating Limits Report Ladies and Gentlemen:

Pursuant to the reporting requirements of Vogtle Electric Generating Plant (VEGP)

Technical Specification 5.6.5 Southern Nuclear Operating Company (SNC) is submitting Revision 1 of the Unit 1 Cycle 13 Core Operating Limits Report (COLR).

This letter contains no NRC commitments. If you have any questions, please advise.

Sincerely,

Enclosure:

Unit 1 Cycle 13 Core Operating Limits Report (Revision 1) cc: Southern Nuclear Operating Company Mr. J. T. Gasser, Executive Vice President Mr. T. E. Tynan, General Manager -Plant Vogtle RType: CVC7000 U. S. Nuclear Regulatorv Commission Dr. W. D. Travers, Regional Administrator Mr. C. Gratton, NRR Project Manager - Vogtle Mr. G. J. McCoy, Senior Resident Inspector - Vogtle

VOGTLE ELEC-TRIC GENERATING PLANT (VEGP) UNIT 1 CYCLE 13 CORE OPERATING LIMITS REPORT REVISION 1 NOVEMBER 2005

COLR for VEGP UNlT 1 CYCLE 13 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report (COLR) for VEGP UNlT 1 CYCLE 13 has been prepared in accordance with the requirements of Technical Specification 5.6.5.

The Technical Requirement affected by this report is listed below:

13.1.1 SHUTDOWN MARGIN - MODES 1 and 2 The Technical Specifications affected by this report are listed below:

3.1.I SHUTDOWN MARGIN - MODES 3,4and 5 3.1.3 Moderator Temperature Coefficient 3.1.5 Shutdown Bank Insertion Limits 3.1.6 Control Bank Insertion Limits 3.2.1 Heat Flux Hot Channel Factor - FQ(Z) 3.2.2 Nuclear Enthalpy Rise Hot Channel Factor - Fk 3.2.3 Axial Flux Difference 3.9.1 Boron Concer~tration PAGE 1 of 21

COLR for VEGP UNIT 1 CYCLE 13 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in section 1.0 are presented in the following subsections. These limits have been developed using NRC-approved methodologies, including those specified in Technical Specification 5.6.5.

2.1 SHUTDOWN MARGIN - MODES 1 AND 2 (Technical Requirement 13.1.1) 2.1.1 The SHUTDOWN MARGIN shall be greater than or equal to 1.30percent Auk.

2.2 SHUTDOWN MARGIN - MODES 3.4 AND 5 (Specification 3.1.l) 2.2.1 The SHUTDOWN MARGIN shall be greater than or equal to the limits shown in Figures 1 and 2.

2.3 Moderator Temperature Coefficient (Specification 3.1.3) 2.3.1 The Moderator Temperature Coefficient (MTC) limits are:

The BOUAROIHZP - MTC shall be less positive than +0.7x lo4 AWkPF for power levels up to 70 percent RTP with a linear ramp to 0 AWkPF at 100 percent RTP.

The EOUAROIRTP-MTC shall be less negative than

-5.50x 1 o4 AWF.'

2.3.2 The MTC Surveillance limits are:

The 300 ppmlARO1RTP-MTC should be less negative than or equal to -4.75x 1o -AklkP~.

~

The 60 ppmlARO1RTP-MTCshould be less negative than

-5.35x 1 o4 A W ~ P F . ~

where: BOL stands for Beginning of Cycle Life ARO stands for All Rods Out HZP stands for Hot Zero THERMAL POWER EOL stands for End of Cycle Life RTP stands for RATED THERMAL POWER 2.4 Shutdown Bank Insertion Limits (Specification 3.1.5) 2.4.1 The shutdown banks shall be withdrawn to a position greater than or equal to 225 steps.

2.5 Control Bank Insertion Limits (Specification 3.1.6) 2.5.1 The control banks shall be limited in physical insertion as shown in Figure 3.

'~pplicablefor full-power T-average of 586.4'F to 587.4'F.

PAGE 2 of 21

COLR for VEGP UNIT 1 CYCLE 13 2.6 Heat Flux Hot Channel Factor - FQ(Z) (Specification 3.2.1)

T FP 2.6.1 FQ(Z) I -* K(Z) for P > 0.5 P

FRTP FQ (Z) 2 05* K(Z) for P I 0.5 THERMAL POWER where: P =

RATED THERMAL POWER 2.6.3 K(Z) is provided in Figure 4.

F : ~ ~ *K(Z) 2.6.4 FQ(z) 5 for P > 0.5 P W(Z)

F ; ~ ~ *K(Z) for P S 0.5 F~(z)' 0.5*W(Z) 2.6.5 W(Z) values are provided based on the following calculated Delta Axial Offset (D-AO):

Calculated D-A0 Max -

Min W(Z) Fiaures Figures 6-9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Where: D-A0 = [(Measured Axial Offset) - (Predicted Axial Offset)]

PAGE 3 of 21

COLR for VEGP UNIT 1 CYCLE 13 BOL - 150 MWDIMTU MOL-1 - 4,000 MWDIMTU MOL-2 = 12,000 MW DWTU EOL = 20,000 MWDIMTU 2.6.6 The FQ(Z)penalty factors are provided in Table 1.

2.7 Nuclear Enthal~vRise Hot Channel Factor - (Specification 3.2.2)

THERMAL POWER where: P =

RATED THERMAL POWER 2.8 Axial Flux Difference (Specification 3.2.3) 2.8.1 The Axial Flux Difference (AFD) acceptable operation limits are provided in Figure 5.

2.9 Boron Concentration (Specification 3.9.1) 2.9.1 The boron concentration shall be greater than or equal to 1935 ppm.'

his concentration bounds the condition of keff5 0.95 (all rods in less the most reactive rod) and subcriticality (aJ rods out) over the entire cycle. This concentration includes additional boron to address uncertainties and B depletion.

PAGE 4 of 21

COLR for VEGP UNIT 1 CYCLE 13 TABLE 1 FQ(Z)PENALTY FACTOR Cycle Fa(Z)

Burnup Penalty (MWDIMTU) Factor Notes:

1. The Penalty Factor, to be applied to FQ(Z)in accordance with SR 3.2.1.2,is the maximum factor by which FQ(Z)is expected to increase over a 39 EFPD interval (surveillance interval of 31 EFPD plus the maximum allowable extension not to exceed 25% of the surveillance interval per SR 3.0.2)starting from the burnup at which the FQ(Z) was determined.
2. Linear interpolation is adequate for intermediate cycle burnups.
3. For all cycle burnups outside the range of the table, a penalty factor of 1.020 shall be used.

PAGE 5 of 21

COLR for VEGP UNIT 1 CYCLE 13 211bi RCS BORON CONCENTRATION (ppm)

FIGURE 1 REQUIRED SHUTDOWN MARGIN FOR MODES 3 AND 4 (FOUR LOOPS FILLED AND VENTED AND AT LEAST ONE REACTOR COOLANT PUMP RUNNING)

PAGE 6 of 21

COLR for VEGP UNIT 1 CYCLE 13 FIGURE 2 REQlllRED SHUTDOWN MARGIN FOR MODES 4 AND 5 (MODE 4 WHEN FIGURE 1 NOT APPLICABLE)

PAGE 7 of 21

COLR for VEGP UNIT 1 CYCLE 13 (Fully Withdrawn *)

21R1 POWER (percent of Rated Thermal Power)

  • Fully withdrawn shall be the condition where conbol rods are at a position within the interval 2225 and 5231 steps withdrawn.

NOTE: The Rod Bank Insertion Limits are bas+ on the control bank withdrawal sequence A, 8, C, D and a control bank Upto-t~p distance of 115 steps FIGURE 3 ROD BANK INSERTION LIMITS VERSUS % OF RATED THERMAL POWER

COLR for VEGP UNIT 1 CYCLE 13 4.0 6.0 8.0 CORE HEIGHT (ft)

FIGURE 4 K(Z) NORMAI-IZED FQ(Z) AS A FUNCTION OF CORE HEIGHT PAGE 9 of 21

COLR for VEGP UNIT 1 CYCLE 13 FIGURE 5 AXIAL FLUX DIFFERENCE LIMITS AS A FUNCTION OF % OF RATED THERMAL POWER FOR RAOC PAGE 10 of 21

COLR for VEGP UNIT 1 CYCLE 13 Axial Elevation BOL Point (feet) W(ZJ 1 12.00 1.0000 2 11.80 1.0000 3 11.60 1.0000 4 11.40 1.0000 5 11.20 1.0000 6 11.00 1.OOOO 7 10.80 1.0000 8 10.60 1.0000 9 10.40 1.OOOO 10 10.20 1.0000 11 10.00 1.2472 12 9.80 1.2413 13 9.60 1.2350 14 9.40 1.2285 15 9.20 1.2228 16 9.00 1.2142 Core Height - feet This flgure b referred to by Speclflcation B3.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tae temperature range from 586.4 to 587.4'F.

Top aod Boaom 15% Excluded per Technical Specification B3.2.1 FIGURE 6 RAOC W(Z) AT 150 MWD/MTU W(Z) VALID FOR DELTA-A0 OF +3% to -3%

SEE COLR SECTION 2.6.5 PAGE 11 of 21

COLR for VEGP UNIT 1 CYCLE 13 Axial Elevation MOL-I Point (feet) W(Z>

1 12.00 1.oooo 11.80 1.oooo 11.60 1.oooo 11.40 1.0000 11.20 1.oooo 11.oo 1.oooo 10.80 1.oooo 10.60 1.0000 10.40 1.woo 10.20 1.oooo 10.00 1.2825 9.80 1.2720 9.60 1.2625 9.40 9.20 9.00 8.80 8.60 8.40 8.20 8.00 7.80 7.60 7.40 Core Height - feet This f i u r e is referred to by Specification B3.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP,T temperature range from 586.4 to 587A0E Top and Bottom 15% Excluded per Technical Specification B3.2.1 FIGURE 7 RAOC W(Z) AT 4000 MWDIMTU W(Z) VALID FOR DELTA-A0 OF +3% to -3%

SEE COLR SECTION 2.6.5 PAGE 12 of 21

COLR for VEGP UNIT 1 CYCLE 13 Axial Elevation MOL-2 Point 1

2 3

0.0 2.0 4.0 6.0 8.0 10.0 12.0; Core Height - feet

  • This figure is referred to by SpecificationB3.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tax temperature range from 586.4 to 587A°F.

Top and Bottom 15% Excluded per Technical SpecificationB3.2.1 FIGLIRE 8 RAOC W(Z) AT 12000 MWDIMTU W(Z) VALID FOR DELTA-A0 OF +3% to -3%

SEE COLR SECTION 2.6.5 PAGE 13 of 21

COLR for VEGP UNIT 1 CYCLE 13 Axial Elevation EOL Point 1

Core Height - feet This figure is referred to by Speclflcation B3.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tax temperature range from 586.4 to 587.4'F.

Top and Bottom 15% Excluded per Technical Specification B3.2.1 FIGURE 9 RAOC W(Z) AT 20000 MWD/MTU W(Z) VALID FOR DELTA-A0 OF +3% to -3%

SEE COLR SECTION 2.6.5 PAGE 14 of 21

COLR for VEGP UNIT 1 CYCLE 13 Point Feet BOL W (2) EOL W(Z) 1 12.00 1 .0000 1.0000 2 1 1 .80 1.0000 1 .oooo 3 11.60 1.0000 1.0000 4 11.40 1 .moo 1 .woo 5 11.20 1 .moo 1 .0000 6 1 1 .oo 1.0000 1 .0000 7 10.80 1 .woo 1 .0000 8 10.60 1 .0000 1 .ow0 9 10.40 1.0000 1 .ow0 10 10.20 1 .0000 1.0000 11 10.00 1.2721 1.2537 12 9.80 1.2661 1.2508 13 9.60 1.2597 1.2494 14 9.40 1.2531 1.2512 15 9.20 1.2473 1.2621 16 9.00 1.2385 1.2692 17 8.80 1.2390 1.2758 18 8.60 1.2466 1.2812 19 8.40 1.2539 1.2870 20 8.20 1.2595 1.2988 21 8.00 1.2617 1.3066 22 7.80 1.2665 1.3044 23 7.60 1.2713 1.3154 24 7.40 1.2722 1.3216 25 7.20 1.2706 1.3246 26 7.00 1.2666 1.3243 27 6.80 1.2357 1.3209 28 6.60 1.2279 1.3147 29 6.40 1.2182 1.3058 30 6.20 1.2070 1.2945 31 6.00 1.1994 1.2805 32 5.80 1.1727 1.2420 33 5.60 1.1699 1.2339 34 5.40 1.1736 1.2332 35 5.20 1.1865 1.2361 36 5.00 1.1994 1.2378 37 4.80 1.2107 1.2372 38 4.60 1.2215 1.2345 39 4.40 1.2323 1.2298 40 4.20 1.2438 1.2229 41 4.00 1.2543 1.2141 42 3.80 1.2592 1.2033 43 3.60 1.2633 1 .I927 44 3.40 1.2659 1.1833 45 3.20 1.2666 1.1718 46 3.00 1.2767 1.1820 47 2.80 1.2976 1.1870 48 2.60 1.3227 1.1987 49 2.40 1.3467 1.2090 50 2.20 1.3703 1.2193 51 2.00 1.3935 1.2296 52 1.80 1 .moo 1 .woo 53 1.60 1 .oow 1 .woo 54 1.40 1 .oooo 1 .oooo 55 1.20 1 .oooo 1.0000 56 1.00 1 .0000 1.0000 57 0.80 1 .0000 1.0000 58 0.60 1 .woo 1 .ow0 59 0.40 1 .moo 1 .om0 60 0.20 1 .00w 1.0000 61 0.00 1 .woo 1.0000 Top and bottom 15 % excluded per Technical Specificatlon 83.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tavg temperature range from 586.4 to 587.4"F.

FIGURE 10 RAOC W(Z) FOR DELTA-A0 BETWEEN < -3% to -4%

SEE COLR SECTION 2.6.5 PAGE 15 of 21

COLR for VEGP UNIT 1 CYCLE 13 Point Feet BOL W (Z) EOL W (Z) 1 12.00 1.0000 1.0000 2 11.80 1.0000 1.0000 3 11.60 1.0000 1 .0000 4 11.40 1.0000 1.0000 5 11.20 1.0000 1.0000 6 11.00 1 .0000 1.0000 7 10.80 1 .00w 1.0000 8 10.60 1.0000 1.0000 9 10.40 1.0000 1.0000 10 10.20 1.0000 1 .0000 11 10.00 1.2971 1.2783 12 9.80 1.2910 1.2754 13 9.60 1.2844 1.2739 14 9.40 1.2776 1.2758 15 9.20 1.2717 1.2869 16 9.00 1.2628 1.2941 17 8.80 1.2633 1 .3008 18 8.60 1.2711 1.3063 19 8.40 1.2785 1.3123 20 8.20 1.2042 1.3242 21 8.00 1.2865 1.3322 22 7.80 1.2914 1.3300 23 7.60 1.2963 1.3412 24 7.40 1.2972 1.3475 25 7.20 1.2955 1.3505 26 7.00 1.2915 1.3502 27 6.80 1.2600 1.3468 28 6.60 1.2520 1.3405 29 6.40 1.2421 1.3314 30 6.20 1.2306 1.3199 31 6.00 1.2229 1.3056 32 5.80 1.1727 1.2420 33 5.60 1.1699 1.2339 34 5.40 1.1736 1.2332 35 5.20 1.1865 1.2361 36 5.00 1.1994 1.2378 37 4.80 1.2107 1.2372 38 4.60 1.2215 1.2345 39 4.40 1.2323 1.2298 40 4.20 1.2438 1.2229 41 4.00 1.2543 1.2141 42 3.80 1.2592 1.2033 43 3.60 1.2633 1.1927 44 3.40 1.2659 1.1833 45 3.20 1.2666 1.1718 46 3.00 1.2767 1.1820 47 2.80 1.2976 1.1870 48 2.60 1.3227 1.1987 49 2.40 1.3467 1.2090 50 2.20 1.3703 1.2193 51 2.00 1.3935 1.2296 52 1 .80 1.0000 1.0000 53 1.60 1.0000 1.0000 54 1.40 1.0000 1 .0000 55 1.20 1.0000 1 .0000 56 1 .oo 1.0000 1. m o 57 0.80 1.0000 1.0000 58 0.60 1.0000 1.0000 59 0.40 1.0000 1.0000 60 0.20 1.0000 1 .0000 61 0.00 1.0000 1.0000 Top and bottom 15 % excluded per Technical Specification B3.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tavg temperature range from 586.4 to 587.4"F.

FIGURE 11 RAOC W(Z) FOR DELTA-A0 BETWEEN < -4% to -5%

SEE COLR SECTION 2.6.5 PAGE 16 of 21

COLR for VEGP UNIT 1 CYCLE 13 Point Feet BOL W(Z) EOL W(Z) 1 12.00 1.0000 1.0000 2 11.80 1.0000 1 .0000 3 1 1.60 1.0000 1.0000 4 1 1.40 1 .00M) 1.0000 5 1 1.20 1.0000 1 .0000 6 1 1 .oo 1 .0000 1.0000 7 10.80 1.0000 1.0000 8 10.60 1.0000 1.0000 9 10.40 1.0000 1.0000 10 10.20 1.0000 1.0000 11 10.00 1.3220 1.3028 12 9.80 1.3158 1.2999 13 9.60 1.3091 1.2984 14 9.40 1.3022 1. a 3 15 9.20 1.2962 1.3116 16 9.00 1.2871 1.3190 17 8.80 1.2876 1.3258 18 8.60 1.2955 1.3315 19 8.40 1 3031 1.3375 20 8.20 1.3089 1.3497 21 8.00 1.3112 1.3579 22 7.80 1.3162 1.3555 23 7.60 1.3212 1.3670 24 7.40 1.3221 1.3734 25 7.20 1.3204 1.3765 26 7.00 1.3163 1.3762 27 6.80 1.2842 1.3727 28 6.60 1.2760 1.3662 29 6.40 1.2660 1.3570 30 6.20 1.2543 1.3452 31 6.00 1.2465 1.3307 32 5.80 1 .I727 1.2420 33 5.60 1.1699 1.2339 34 5.40 1.1736 1.2332 35 5.20 1.1865 1.2361 36 5.00 1.1994 1.2378 37 4.80 1.2107 1.2372 38 4.60 1.2215 1.2345 39 4.40 1.2323 1.2298 40 4.20 1.2438 1.2229 41 4.00 1.2543 1.2141 42 3.80 1.2592 1.2033 43 3.60 1.2633 1.1927 44 3.40 1.2659 1.1833 45 3.20 1.2666 1.1718 46 3.00 1.2767 1.1820 47 2.80 1.2976 1.1870 48 2.60 1.3227 1.1987 49 2.40 1.3467 1.2090 50 2.20 1.3703 1.2193 51 2.00 1.3935 1.2296 52 1.80 1 .ow0 1 ,0000 53 1.60 1 .Ow0 1.0000 54 1.40 1.0000 1.0000 55 1.20 1 .oooo 1 .ow0 56 1 .oo 1 .moo 1.0000 57 0.80 1 .WOO 1 .oooo 58 0.60 1 .WOO 1 .oooo 59 0.40 1.0000 1 .mo 60 0.20 1.0000 1.0000 61 0.00 1.0000 1 .woo Top and bottom 15 % excluded per Technical Specification 83.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tavg temperature range from 586.4 to 587.4OF.

FIGURE 12 RAOC W(Z) FOR DELTA-A0 BETWEEN < -5% to -6%

SEE COLR SECTION 2.6.5 PAGE 17 of 21

COLR for VEGP UNIT 1 CYCLE 13 Point Feet BOL W (Z) MOL-2 W (Z) EOL W (Z) 1 12.00 1.0000 1.0000 1.0000 2 11.80 1.0000 1.0000 1.0000 3 11.60 1.woo 1.0000 1.0000 4 11.40 1.0000 1.0000 1.0000 5 11.20 1.0000 1.0000 1.0000 6 11.oo 1.woo 1.0000 1.mo 7 10.80 1.0000 1.0000 1.0000 8 10.60 1.woo 1.0000 1.0000 9 10.40 1.woo 1.0000 1.0000 10 10.20 1.woo 1.0000 1.0000 11 10.00 1.3470 1.3832 1.3274 12 9.80 1.3406 1.3706 1.3244 13 9.60 1. a 3 8 1.3647 1.3229 14 9.40 1.3268 1.3569 1.3248 15 9.20 1.3206 1.3451 1.3364 16 9.00 1.3113 1.3351 1.3438 17 8.80 1.3119 1.3226 1.3509 18 8.60 1.3200 1.3168 1.3566 19 8.40 1.3276 1.3201 1.3627 20 8.20 1.3336 1.3197 1.3752 21 8.00 1.3360 1.3226 1.3835 22 7.80 1.3410 1.3272 1.3811 23 7.60 1.3461 1.3283 1.3928 24 7.40 1.3471 1.3270 1.3994 25 7.20 1.3454 1.3230 1.4025 26 7.00 1.341 1 1.3166 1.4022 27 6.80 1.3084 1.3082 1.3986 28 6.60 1.NO1 1.2977 1.3920 29 6.40 1.2898 1.2858 1.3826 30 6.20 1.2780 1.2739 1.3706 31 6.00 1.2700 1.2625 1.3558 32 5.80 1.1727 1.1618 1.2420 33 5.60 1.1699 1.1612 1.2339 34 5.40 1.1736 1.1668 1.2332 35 5.20 1.1865 1.1719 1.2361 36 5.00 1.1994 1.I 758 1.2378 37 4.80 1.2107 1.1784 1.2372 38 4.60 1.2215 1.1798 1.2345 39 4.40 1.2323 1.1798 1.2298 40 4.20 1.2438 1.1785 1.2229 41 4.00 1.2543 1.1761 1.2141 42 3.80 1.2592 1.1723 1.2033 43 3.60 1.2633 1.1680 1.1927 44 3.40 1.2659 1.1642 1.1833 45 3.20 1.2666 1.1630 1.1718 46 3.00 1.2767 1.1675 1.1820 47 2.80 1.2976 1.1773 1.1870 48 2.60 1.3227 1.1870 1.1987 49 2.40 1.3467 1.1964 1.2090 50 2.20 1.3703 1.2056 1.2193 51 2.00 1.3935 1.2148 1.2296 52 1.80 1.om 1.0000 1.0000 53 1.60 1.0000 1.0000 1.0000 54 1.40 1.0000 1.0000 1.0000 55 1.20 1.woo 1.0000 1.0000 56 1.oo 1.woo 1.0000 1.0000 57 0.80 1.0000 1.0000 1.0000 58 0.60 1.woo 1.0000 1.0000 59 0.40 1.woo 1.0000 1.0000 60 0.20 1.ow0 1.0000 1.0000 61 0.00 1.oooo 1.0000 1.0000 Top and bottom 15 % excluded per Technical Specification 83.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tavg temperature range from 586.4 to 587.4"F.

FIGURE 13 RAOC W(Z) FOR DELTA-A0 BETWEEN < -6% to -7%

SEE COLR SECTION 2.6.5 PAGE 18 of 21

COLR for VEGP UNIT 1 CYCLE 13 Point Feet BOL W (Z) dOL-2 W (Z) EOL W (Z) 1 12.00 1.0000 1.0000 1.0000 2 11.80 1.0000 1.0000 1.0000 3 11.60 1.0000 1.0000 1.0000 4 11.40 1.0000 1.0000 1.0000 5 11.20 1.0000 1.0000 1.0000 6 11.00 1.0000 1.0000 1.0000 7 10.80 1.0000 1.0000 1.0000 8 10.60 1.0000 1.0000 1.0000 9 10.40 1.0000 1.0000 1.0000 10 10.20 1.0000 1.0000 1.0000 11 10.00 1.3719 1.4088 1.3520 12 9.80 1.3654 1.3960 1.3489 13 9.60 1.3585 1.3900 1.3474 14 9.40 1.3514 1.3820 1.3494 15 9.20 1.3451 1.3701 1.3611 16 9.00 1.3356 1.3598 13687 17 8.80 1.3362 1.3471 1.3759 18 8.60 1.3444 1.3412 1.3817 19 8.40 1.3522 1. a 4 5 1.3880 20 8.20 1.3583 1.3441 1.4006 21 8.00 1.3607 1.3471 1.4091 22 7.80 1.3659 1.3518 1.4067 23 7.60 1.3710 1.3529 1.4186 24 7.40 1.3720 1.3516 1.4253 25 7.20 1.3703 1.3475 1.4285 26 7.00 1.3660 1.3410 1.4281 27 6.80 1.3327 1.3324 1.4245 28 6.60 1.3242 1.3218 1.4178 29 6.40 1.3137 1.3097 1.4082 30 6.20 1.3016 1.2975 1.3960 31 6.00 1.2935 1.2859 1.3809 32 5.80 1.1727 1.1618 I .2420 33 5.60 1.I699 1.1612 1.2339 34 5.40 1.1736 1.1668 1.2332 35 5.20 1.1865 1.I719 1.2361 36 5.00 1.1994 1.1758 1.2378 37 4.80 1.2107 1.1784 1.2372 38 4.60 1.2215 1.1798 1.2345 39 4.40 1.2323 1.1798 1.2298 40 4.20 1.2438 1.1785 1.2229 41 4.00 1.2543 1.1761 1.2141 42 3.80 1.2592 1.1723 1.2033 43 3.60 1.2633 1.1680 1.1927 44 3.40 1.2659 1.1642 1.1833 45 3.20 1.2666 1.1630 1.1718 46 3.00 1.2767 1.1675 1.1820 47 2.80 1.2976 1.1773 1.1870 48 2.60 1.3227 1.1870 1.1987 49 2.40 1.3467 1.1964 1.2090 50 2.20 1.3703 1.2056 1.2193 51 2.00 1.3935 1.2148 1.2296 52 1.80 1.0000 1.0000 1.0000 53 1.60 1.0000 1.0000 1.om0 54 1.40 1.moo 1.0000 1.0000 55 1.20 1.0000 1.0000 1.0000 56 1.00 1.0000 1.moo 1.0000 57 0.80 1.0000 1.moo 1.0000 58 0.60 1.0000 1.00w 1.0000 59 0.40 1.0000 1.0000 1.0000 60 0.20 1.0000 1.0000 1.0000 61 0.00 1.moo 1.0000 1.woo Top and bottom 15 % excluded per Technical Specification 83.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tavg temperature range from 586.4 to 587.4"F.

FIGURE 14 RAOC W(Z) FOR DELTA-A0 BETWEEN < -7% to -8%

SEE COLR SECTION 2.6.5 PAGE 19 of 21

COLR for VEGP UNIT 1 CYCLE 13 Point BOL W(Z) MOL-2 W(Z) EOL W(Z) 1 1.0000 1.0000 1.0000 2 1.0000 1.0000 1.0000 3 1.0000 1.0000 1.0000 4 1.0000 1.0000 1.0000 5 1.0000 1.0000 1.oow 6 1.0000 1.0000 1.0000 7 1.0000 1.0000 1.0000 8 1.0000 1.0000 1.0000 9 1.woo 1.0000 1.0000 10 1.0000 1.0000 1.0000 11 1.4218 1.4600 1.4012 12 1.4151 1.4468 1.3980 13 1.4079 1.4405 1.3964 14 1.4w5 1.4323 1.3984 15 1.3940 1.4199 1.4106 16 1.3842 1.4093 1.4185 17 1.3848 1.3960 1.4259 18 1.3933 1.3900 1.4320 19 1.4014 1.3934 1.4385 20 1.4077 1.3930 1.4516 21 1.4102 1.3960 1.4603 22 1.4155 1.4009 1.4578 23 1.4209 1.4021 1.4701 24 1.4219 1.4007 1.4771 25 1.4201 1.3965 1.4804 26 1.4157 1.3898 1.4801 27 1.3811 1.3809 1.4763 28 1.3723 1.3698 1.4693 29 1.3615 1.3573 1.4594 30 1.3490 1.3446 1.4468 31 1.3405 1.3327 1.4312 32 1.1727 1.1618 1.2420 33 1.1699 1.1612 1.2339 34 1.1736 1,1668 1.2332 35 1.1865 1.1719 1.2361 36 1.1994 1.I 758 1.2378 37 1.2107 1.1784 1.2372 38 1.2215 1.1798 1.2345 39 1.2323 1.1798 1.2298 40 1.2438 1.1785 1.2229 41 1.2543 1.1761 1.2141 42 1.2592 1.I723 1.2033 43 1.2633 1.1680 1.1927 44 1.2659 1.1642 1.1833 45 1.2666 1.1630 1.1718 46 1.2767 1.1675 1.1820 47 1.2976 1.1773 1.1870 48 1.3227 1.1870 1.1987 49 1.3467 1.I964 1.2090 50 1.3703 1.2056 1.2193 51 1.3935 1.2148 1.2296 52 1.0000 1.0000 1.0000 53 1.ww 1.ww 1.owo 54 1.woo 1.0000 1.owo 55 1.0000 1.ww 1.0000 56 1.0000 1.woo 1.0000 57 1.oow 1.0000 1.0000 58 1.0000 1.0000 1.0000 59 1.0000 1.0000 1.0000

' 6 0 1.0000 1.0000 1.0000 61 1.ww 1.0000 1.0ow Top and bottom 15 % excluded per Technical Specification83.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tavg temperature range from 586.4 to 587.4"F.

FIGURE 15 RAOC W(Z) FOR DELTA-A0 BETWEEN < -8% to -10%

SEE COLR SECTION 2.6.5 PAGE 20 of 21

COLR for VEGP UNIT 1 CYCLE 13 Point Feet BOL W(Z) MOL-2 W(Z) EOL W(Z) 1 12.00 1.0000 1.0000 1.0000 2 11.80 1.0000 1.0000 1.0000 3 11.60 1.0000 1.0000 1.0000 4 11.40 1.0000 1.0000 1.0000 5 11.20 1.0000 1.0000 1.0000 6 11.00 1.0000 1.0000 1.0000 7 10.80 1.WOO 1.0000 1.0000 8 10.60 1. M O O 1.0000 1.0000 9 10.40 1.0000 1.0000 1.0000 10 10.20 1.00w 1.0000 1.0000 11 10.00 1.4717 1.5112 1.4503 12 9.80 1.4647 1.4975 1.4470 13 9.60 1.4573 1.4910 1.4454 14 9.40 1.4496 1.4826 1.4475 15 9.20 1.4429 1.4697 1.4601 16 9.00 1.4328 1.4587 1.4683 17 8.80 1.4333 1.4450 1.4759 18 8.60 1.4422 1.4388 1.4822 19 8.40 1.4506 1.4423 1.4889 20 8.20 1.4571 1.4418 1.5025 21 8.00 1.4597 1.4450 1.5116 22 7.80 1.4652 1.4501 1.5090 23 7.60 1.4708 1.4513 1.5217 24 7.40 1.4718 1.4499 1.5289 25 7.20 1.4699 1.4455 1.5323 26 7.00 1.4653 1.4385 1.5320 27 6.80 1.4296 1.4293 1.5281 28 6.60 1.4205 1.4179 1.5209 29 6.40 1.4093 1.4049 1.5106 30 6.20 1.3963 1.3918 1.4975 31 6.00 1.3876 1.3794 1.4814 32 5.80 1.1727 1.1618 1.2420 33 5.60 1.1699 1.1612 1.2339 34 5.40 1.1736 1.1668 1.2332 35 5.20 1.1865 1.1719 1.2361 36 5.00 1.1994 1.1758 1.2378 37 4.80 1.2107 1.1784 1.2372 38 4.60 1.2215 1.1798 1.2345 39 4.40 1.2323 1.1798 1.2298 40 4.20 1.2438 1.1785 1.2229 41 4.00 1.2543 1.1761 1.2141 42 3.80 1.2592 1.1723 1.2033 43 3.60 1.2633 1.1680 1.1927 44 3.40 1.2659 1.1642 1.1833 45 3.20 1.2666 1.1630 1.1718 46 3.00 1.2767 1.1675 1.1820 47 2.80 1.2976 1.1773 1.1870 48 2.60 1.3227 1.1870 1.1987

- 49 2.40 1.3467 1.1964 1.2090 50 2.20 1.3703 1.2056 1.2193 51 2.00 1.3935 1.2148 1.2296 52 1.80 1.0000 1.0000 1.0000 53 1.60 1.WOO 1.0000 1.0000 54 1.40 1.0000 1.0000 1.0000 55 1.20 1.0000 1.0000 1.0000 56 1.00 1.0000 1.0000 1.0000 57 0.80 1.0000 1.0000 1.0000 58 0.60 1.WOO 1.0000 1.0000 59 0.40 1.OOOO 1.0000 1.0000 60 0.20 1.moo 1.0000 1.0000 61 0.00 1.0000 1.0000 1.0000 Top and bottom 15 % excluded per Technical Specification 83.2.1 These W(Z) values are consistent with Figure 5, and are valid over the HFP Tavg temperature range from 586.4 to 587.4"F.

FIGURE 16 RAOC W(Z) FOR DELTA-A0 BETWEEN < -10% to -12%

SEE COLR SECTION 2.6.5 PAGE 21 of 21