NG-03-0509, Inservice Inspection Report

From kanterella
Jump to navigation Jump to search
Inservice Inspection Report
ML032110050
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 07/18/2003
From: Peifer M
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NG-03-0509
Download: ML032110050 (197)


Text

NMCS Committed to Nuclear Excellence Duane Arnold Energy Center Operated by Nuclear Management Company, LLC July 18, 2003 NG-03-0509 10 CFR 50.55a Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station 0-PI-17 Washington, DC 20555-0001 DUANE ARNOLD ENERGY CENTER DOCKET 50-331 LICENSE No. DPR-49 INSERVICE INSPECTION REPORT In accordance with the requirements of Paragraph IWA-6230 in Section Xl of the ASME Boiler and Pressure Vessel Code and 10 CFR Section 50.55a(g), Nuclear Management Company, LLC (NMC) herewith submits the Refueling Outage (RFO) 18 Inservice Inspection Summary Reports (Attachments 1 and 2). These reports address examinations which were performed at the Duane Arnold Energy Center (DAEC) during the time period from May 28, 2001 through April 20, 2003. provides information regarding augmented inservice inspections performed during RFO 18. These inspections include those performed for NUREG-0313, Revision 2, "Technical Report on Material Selection and Processing Guidelines for BWR Coolant Pressure Boundary Piping," NUREG-0619, BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking," and Bulletin 80-13, Cracking in Core Spray Spargers."

NMC's review of the inspection reports has determined that all examined items are acceptable.

These inspection reports are on file and are available for review upon request.

This letter contains no new commitments.

Sire I Site Vice President, Duane Arnold Energy Center Attachments 1. ASME Section Xl Summary Report, Duane Arnold Energy Center, Refueling Outage 18 (Period 2)

2. ASME Section Xl Summary Report, Duane Arnold Energy Center, Refueling Outage 18 (Period 3)
3. Augmented Inspection Results RFO 18 CC. Regional Administrator, USNRC, Region IlIl Project Manager (DAEC)

NRC Resident Inspector (DAEC) 3277 DAEC Road

  • Palo, Iowa 52324-9785 Telephone: 319.851.7611

Attachment I to NG-03-0509 ASME Section Xi Summary Report Duane Arnold Energy Center Refueling Outage 18 (Period 2)

25 Yearsl of v , - I Rock Solid-Performance ASME Section Xl Summary Report Duane Arnold Energy Center Refueling Outage 18 (Period 2)

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May28, 2001 through April 20, 2003 DUANE ARNOLD ENERGY CENTER UN1T #1 PALO, IOWA Conmercial Service Date: February 1, 1975 THIRD TEN YEAR IN1ERVAL INSERVICE INSPECTION

SUMMARY

REPORT May28,2001 irough April 20,2003 Dated: April 20,2003 OWNER:

ALLIANT ENERGY P.O. Box 351 Cedar Rapids, Iowa 52406 Prepared by.: Date: 7______3 Reviewed b3r: _ Le

__ _ __ Date: 6 NDE Lcvel ml Reviewed by. Date: 7 0 3 Programn Engieering Staff Reviewed by. Date: 7-/C- 3_

Proganieabri Mgr supefi Concurred by. Date: 7 1 03 Program Engineering Manager

I I THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20, 2003 This page intentionally blank

TIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May28, 2001 through April 20, 2003 Part A, Page 1 of 2 FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules I.Owner Interstate Power and Lipt Companv. an Alliant Con Lanv. P.O. Box 351.Cedar RapidsiA 52406 *

(Name and address of Owner)

'2. Plant Duane Arnold Enerv Center. 3277 DAEC Road. Palo. IA 52324 (Name and Address of Plant)

3. Plant Unit 1 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 02/01n5 6. National Board Number of Unit - N/A _
7. Components Inspected This report includes a Table of Contents (P1), Part A (PP1-2), Part B (PP1-2), Part C (P1), Part D (PP1-2), Part E (P1),

Part F (PP1-2), Part G (PP1-68), Part H (P1), Part I (PP1-14),

Part J (PP1-4), and Part K (P1).

Manufacturer

,Conponent or Manufacturer I er State or National Appurtenance or Installer Serial No. Province No. Board No.

Reactor Chicago Bridge Pressure & Irn 34833 N/A 3663 Vessel (RPV)

Refer to Part B.Pages 1-2, of thi report for a continuation of comoet examined I , ~~I I -I

-~~ I I Note: Supplemental sheets in fotn of lists, dstches, or drawings may be used provided (1) size is 853 X 1 inches, (2) information in items I through 6 on this dat report is included on each sheet, and (3) each sheet is numbered sod the nunber of sheets is recorded at the top of this form.

(12482) This frm (E00029) nmay be obained fino the OrderDpt, ASME. 345 . 47th St, Ncw Yod, NY 10010

THIRD TEN YEAR INTERVAL.

INSERVICE INSPECTION REPORT May 28, 2001 through April 20,2003 Part A, Page 2 of 2 FORM NIS-1 (back)

8. Examination Dates 5/2801 to 4120/03 9. Inspection Interval from 11/01/96 to 11/01/05
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval.

Refer to Part C, Part D, and Part J.

11. Abstract of Conditions Noted Refer to Part H.
12. Abstract of Corrective Measures Recommended and Taken Refer to Part H.

We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section X.

Date JALI 7 2003 Signed a --- J By Certificate of Authorization No. (ifapplicable) .J l Expiration Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of Iowa and employed by HSB CT of Hartford CT have inspected the components described in this Owner's Data Report during the period 528/01 to 04/20/03 and state that to the best of myknowledge and belief, the Ownerhas performed examinations and taken corrective measures described in this Owner's Data Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Data Report. Furthermore, neither the Inspector, nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 7-, -7 2003.

_____________________- ___________________ Commissions lQ Inspector's Signature National Board, State, Province and No.

  • Note - Oder owners are CentWa Iowa Power Cooperative and Corn Bet Power Cooperative.

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28,2001 through April 20,2003 Part B, page 1 of 2

1) Own - InterstatePowerand Light Copany, Central Iowa Power Cooperative Cmn Beh Power Cooperative an Alliant Company Marion, L4 Humbolt, L P.O. Box 351 Cedar Rapids, LA. 52406
2) Plant: Duane Arnold En Center, Palo, LA. 52324 3) Plant Unit #1
4) Owners Certificate ofAuthorization (if Equd): NA 5) Conunercial Service Date: 02/01l5
6) National Board Nunber of Unit: N(A Gross GeneratingCapacity: 614MWE CERTICATE OF INSERVICE INSPECTION COMPONENTS EXAMINE:

Reactor Pressure Vessel:

Manufacturer- Chicago Bridge and Iron Post Office Box 13308 Memphis, TN 38113 National Board Number 3663, Mfr. Serial Number 3-4833 Refer to Part A, Page 1, form NIS-1, Owners Data Report for Inservice Inspections.

Piping:

Manufacturers, sizes, part numbers and locations are noted and traceable through the piping isometric

--and piping instrumentation drawings (P&ID). Installation contractor, fabricator, systems P&ID's and Isometric drawings are listed below.

Constructor:

Bechtel Power Co.

P.O. Box 3865 San Francisco, CA 94119 Fabricator -

Southwest Fabricating and Welding Co.

P.O. Box 9449 Houston, TX 77011

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20, 2003 Part B, page 2 of 2

1) Owners: Interstate Power and ight Company, Ccotral Iowa Power Coopeafive Corn Belt Power Cooperative an Alliant Company Mnuion, LA Humbolt, IA.

P.O. Box 351 Cedar Rapids, IA. 52406

2) Plant: Duane Amold EnergyCenter, Palo, A.52324 3) PlantUnit: 1
4) Owners Cerdficate ofAudiation (ifrequired): NA 5) Commercial Service Date. 02/0 l5
6) National Board Number of Unit: NA Gros Generating Capacity 614 MWE CERTIFICATE ()F INSERVICE INSPECTION COMPONENTS EXAMINED:

CLASS I Component Iso No Main Steam 1.2-01/-0V-03 Feedwater 12-05/-06 Core Spray 1.2-07 High Pressure Coolant Injection 1.2-09 Recirculation Pump 'A' Suction 1.2-19A Recirculation Manifold 'A' and Risers EFGH 1.2-20 Recirculation Manifold 'B' and Risers ABCD 1.2-22 IvII Component Iso No NO VVI EXAMNATIONS WERE PERFORMED DURING THE SECOND PERIOD FOR THIS CYCLE.

CLASS 2 Component Iso No High Pressure Coolant Injection 2.2441-46

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20,2003 Part C, page I of I

1) Oers: Interstate Power and Light Company, Central low, Power Cooperative Corn Belt Power Cooperative an Alliant Company Maion,dW Humbolt, IA.

P.O. Box 351 Cedar Rapids, LA. 52406

2) Plant Duane Arnold Energy Center, Palo, IA.52324 3) PlantUnit: 1
4) Owners Certificate of Authorizaton (iftequired): N/A 5) Commercial Service Date: 02/0175
6) National Board Number of Unit NIA Gross Generating Capacity 614 MWE CERTIFICATE OF INSERVICE INSPECTION ABSTRACT:

The Inservice hispection addressed in this report was performed in accordance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section Xl 1989 Edition, No Addenda, and the Duane Arnold Energy Center Updated Final Safety Analysis Report The inspections were performed utilizing Non-Destructive Examination Techniques (i e, U1, PT, MT, etc.). The examinations were conducted during the period of May 28,2001 through April20, 2003. The specific details and associated records of the examinations are on file at Duane Arnold Energy Center.

II THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20,2003 This page intentionally blank

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20,2003 TABLE OF CONTENTS PART DESCRIPION PAGE NO.

A FormNIS-1 Pages 1-2 B Certificate ofInservice Inspection Pages 1-2 C Abstract Page I D Table of Component and Weld Exanination Identification Records Pages 1-2 E Table of Additional and Successive Exannations Identification Records Page 1 F Abstract of ASME Section XI Repairs and Replacements Pages 1-2 G FormNIS-2's Pages 1-68 H Abstract of Conditions Noted and Corrective Measures Taken Page 1 I ISI Figures and Isometrics Pages 1-14 J Status of Work for Third Ten Year Interval Pages 1-4 K Listing of Relief Requests and Code Cases Utilized Page I

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20,2003 This page intentionally blank

TIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May28, 2001 through April 20,2003 Part D, page 1 of 2

1) Owners: nerst Power and Light Company, Central Iowa Power Cooperative Corn Belt Power Cooperative an Alliant Company Marion,IAL Hwnbolt, IA.

P.O. Box 351 Cedar Rapids, ILA.

52406

2) Plant Duane Arnold EnergyCenter, Palo, 1A. 52324 3)PantUnit: #1
4) Owners Certificate ofAnirization (frequired): N/A )CommerialService Date: 02iln5
6) National BoardNumberofUnit: N/A Gross Genertg Capacity: 614MWE COMPONENT AND WELD EXAMINATION IDENTIFICATION RECORDS CLASS I j ..

-,~~

ISI ASME XI -.

Component Description Report Examination ISI Iso Category Results Main Steam MSA-J032 103014 UT 1.2-01 R-I Accepted MSA-J033 I03015 UT 12-01 R-I* Accepted MSA-J034 103016 UT 12-01 R-1* Accepted MSB-J00 103023 UT 12-02 R-I* Accepted MSB-J01 1 103044 Ur 12-02 R-I* Accepted MSC-J010 103050 UT 1.2-03 R-I* Accepted Feedwater FWA-J014 EC03080 UT 12-05 R-I* Accepted FWB-J014 EC03014 UT 12-05 R-I* Accepted FWB-JO15 EC03014 UT 12-05 R-1* Accepted FWC-J030 103013 & UT 12-06 R-I Accepted EC03079 FWC-J034A EC03081 UT 12-06 R-I* Accepted

& I03012 Core Spray CSA-J003 103017 UT 12-07 R-l* Accepted High Pressure PSA-J006 103019 UT 12-09 R-I* Accepted Coolant Injection Recirculation RCA-J004 103053 UT 12-19A R-l* Accepted Pump 'A' Suction RCA-J005 103054 UT 1.2-19A R-I* Accepted Recirculation RMA-J001 103041 UT 12-20 R-I* Accepted Manifold 'A' and Risers E,F,G,H RRE-JO05 I03043 UT 12-20 R-I* Accepted RRF-J005 103059 UT 12-20 R-I* Accepted RRG-J005 103058 UT 12-20 R-I* Accepted RRG-J007 103045 UT 12-20 R-I* Accepted Recirculation RRC-JO04A 103057 UT 12-22 R-I* Accepted Manifold 'B' and Risers AB,C,D

  • Risk-Informed process was used.

l CLASS I PRESSURE TESTS I NO CLASS I PRESSURE TESTS WERE PERFORMED DURING THE SECOND PERIOD FOR THIS CYCLE

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May28,2001 through April20,2003 PatDPage2of2 I) Owners: Interstate Power and Light Company, Central Iowa Power Cooperative Corn Belt Power Cooperative an Allint Company Marion, LA Humbolt, UL P.O. Box 351 Cedar Rapids, 1A. 52406

2) Plant: Duane Amold EnergyCenter, Palo, 1A. 52324 3) PlantUnit #1
4) OwnersCatificateofAuthrization(ifrequired): NtA 5) CommercialServiceDate 0210 l5
6) National Board Nunber of Unit: NA Gross Generating Capacity 614 MWE COMPONENT AND WELD EXAMINATION IDENTIICATION RECORDS CLASS2 ISI ASME XI Component Description Report Examination IS1 Iso Category Results Hig Presswue HPA-CF053 103078 UT 2.2-44 R-I* Accepted Coolant Injection BPC-CF029 103082 UT 2.2-46 R-I* Accepted Risk-Informed process was used.

CLASS 2 PRESSURE TESTS ISI ASME Xl Component Description Report Examination ISI ISO Category Results THERE WERE NO CLASS 2 PRESSURE TESTS PERFORMED DURING THE SECOND PERIOD FOR THIS CYCLE Ir IWE COMPONENTS I ISI Exam ASME XI Component Description Report Method ISI ISO Category Results THERE WERE NO IWE COMPONENTS EXAMINED DURING THE SECOND PERIOD FOR THIS CYCLE

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May28, 2001 through April 20,2003 Part E, page of 1 I) Owners: Interstate Power and Light Company, Central Iowa Power Coopetive CoM Bcl Power Cooperative an Alliant Company Marion, LA Humbolt, 1A.

P.O. Box 351 Cedar Rapids, A. 52406

2) Plant: Duane Arnold Energy Center, Palo, 1A. 52324 3) Plant 1Uit: #1
4) Owners Certificate ofAuthorbation (ifrequired): NA S) Comn ercial Service Date- 0210is
6) National Board Nunber oftUnit NA Gross Get rating Capacity: 614 MWE ADDITIONAL EXAMINATION IDENTICATION RECORDS I Component Examined Previous ISI I Report Number IISI Report Number Class I I Examination NO ADDITIONAL EXAMS WERE PERFORMED DURING THE SECOND PERIOD FOR THIS CYCLE ASME XI Category Results SUCCESSIVE EXAMINATION IDENTIFICATION RECORDS I Component Examined l Previous ISI I ReportNumber ISI Report Number ClasslI I

Examination NO SUCCESSIVE EXAMS WERE PERFORMED DURING THE SECOND PERIOD FOR THIS CYCLE I

ASME XI Category I

l Results

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20,2003 This page intentionally blank

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through Apnl 20, 2003 Part F page I of 2 I) Owners: lntrste Power and Ught Company, Central Iowa Power Cooperative Coin Belt Power Cooperative an Alliant Company Marion, Lk Hunbolt A.

P.O. Box 351 Cedar Rapids, 1A. 52406

2) Plant Duane Arnold Energy Center, Palo, LA 52324 3) PlantUnit #1
4) Owners Certificate of Authorization (ifrequie: N/A 5) CenmmercialServiceDate: 02/01/75
6) NationalBoardNmnberofUnit NA Gross Generating Capacity: 614 MWE ABSTRACT OF ASME SECTION I REPAIRS AND REPLACEMENTS The repairs and replacements addressed in this report were performed in accordance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XL 1992 with the 1992 Addenda (Ref. Relief Request NDE-R015 Rev. 1).

NIS-2 NO. CLASS COMPONENT WORKDOCUMT DESCRIPION 18-021 MC Torus Shell CWO A50471 Removed arc striles on Torus Shell.

18-02-04 2 M01933 CWOA57412 Replaced tack weld between disc and disc nut 18-02-06 2 PSV2102 CWO A50455 Replaced with a new relief valve of different design.

1803-03 2 HBB-023-SS-220 PWO 1119896 Replaced snubber.

18-03-05 1 DLA-002-SS-06 CWO A62304 Replaced snubber.

18-03-07 2 HBB-023-SS-219 PWO 1119897 Replaced snubber.

18-03-08 2 IS220 (10-27) PWO 1123629 Replaced CRD Accumulator.

18-03-09 2 XS2618A PWO 1125013 Replaced SBLC Squib Valve.

18-03-10 2 1S220 (22-11) PWO 1123631 Replaced CRD Accumulator.

18-03-11 2 1S220 (34-11) PWO 1123638 Replaced CRD Accumulator.

18-03-12 2 lS220 (10-31) PWO 1123636 Replaced CRD Accumulator.

1843-13 2 1S220 (10-1 1) PWO 1123635 Replaced CRD Accumulator.

1803-14 2 IS220 (30-19) PWO 1123637 Replaced CRD Accumulator.

18-03-15 2 IS220 (26-27) PWO 1123633 Replaced CRD Accumulator.

1803-16 2 1S220 (06-19) PWO 1123630 Replaced CRD Accumulator.

18-03-17 2 lS220 (22-23) PWO 1123632 Replaced CRD Accumulator.

18-03-18 2 1S220 (10-07) PWO 1123634 Replaced CRD Accumulator.

1803-20 2 XS2618B CWO A61392 Replaced SBLC Squib Valve.

18-03-21 1 DLA-2-H-19 MWO 1125194 Removed and reinstalled spring can hanger support 1803-22 1 Main Steam piping CWO A62689 Removed surface defects caused by nearby construction.

18-03-23 1 Recirculation System CWO A60684 Replaced flange on recirculation Piping piping.

18-03-24 MC Drywell MWO 1121803 Installed lifing lugs on Drywell.

18-03-25 2 V25-001 CWO A62296 Machined back of disc for clearance.

18-03-28 1 MSRV Pilot Valve PWO 1119843 Replaced sn 207 with s/n 218.

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20, 2003 Part F, page 2 of 2 I) Owners: Interstate Power and Light Compar, Central Iowa Power Cooperative Corn Belt Power Cooperative

- an Afliant Company Marion,LA Hwnbolt, LA.

P.O. Box 351 Cedar Rapids L 52406

2) Plant Duane Arnold Energy Canter, Pak), A 52324 3) PlantUnit #I
4) Owners Certificate of Audrization (if required): NA 5) Commercial Service Date 02101/75
6) National Board Number of Unit N/A Gms Ga ating Capacity: 614 MWE ABSTRACT OF ASME SECTION Xl REPAIRS AND REPLACEMENTS (conuL)

The repairs and replacements addressed in this report were performed in accordance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section Xl, 1992 with the 1992 Addenda (Ref. Relief Request NDE-RO15 Rev. 1).

NIS-2 NO. CLASS COMPONENT WORK DO DESCREON 18-03-29 I MSRV Pilot Valve PWO 1119844 Replaced s/n 201 with stn 226.

1803-30 I MSRV Pilot Valve PWO 1119845 Replaced stn 200 with sn 189.

18-03-31 I MS Safety Valve PWO 11 19846 Replaced one stud.

18-03-32 1 MSRV Pilot Valve PWO 11 19848 Replaced s/n 176 with s/n 141.

18-03-33 I MSRV Pilot Valve PWO 1119849 Replaced s/n 227 with s/n 203.

18-03-34 I MSRV Pilot Valve PWO I1 19850 Replaced s/n 199 with s/n 202.

18-03-35 I IP201B Pump Seal CWO A58727 Replaced punp seal.

18-03-36 I Rx Head Vent Supports CWO A57816 Modified pipe supports for operational convenience.

1843-37 1 V034)096 CWO A60844 Repaired body-to-bonnet leak

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28,2001 through April 20, 2003 Part 0, page 1 of 68

1) Owners: Interstate Power and Lght Company, Central Iowa Power Cooperative cam Belt Power cooperaive an Alliant Company Maiaon, IA. Humbolt, LA P.O. Box 351 Cedar Rapids I. 52406
2) Plant: DuaneAmoldEncrgyCentrPalo .52324 3) Plant Kkit #1
4) Owner CertificaeofAudorization(ifrquird: N/A 5) Comm acial Service Dte: 02lflS
6) NationalBoardNumberofUnit: N/A Gross Ge =eating Capacity. 614 MWE Form NIS-2's

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20, 2003 Part G, page 2 of 68 This page intentionally blank

Part G, Page 3 of 68 FORM NIS-2 18-02.01 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REACEMENTS As Required by the Prvisions of the ASME Code Section M

1. Owners Afliant EnerM IES OMtes) Date 0212802 Name P. 0. Box 351, CedarRapids,A 52406 Shee 1 of 2 Addres
2. PLan -Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 CWO A50471 Addrew Repair Or niZtionto P. O. No., Job No., etc,
3. Woik Pefformed by Nuclear Ma nagement Co. LC lpe Code Symbol Stamp None Name AuorizationNo. None 3277 DAEC Road, Pal%, IA 5231 24 Expiration Date None
4. Identification of Syst: PdimaY (Torus she)

S. (a) Aplicable Construction Code SM, Sectionm 19 68 Edition W68 Addenda Code Cas (b) Applicable Edition of Section Xl Ulized IbrRepairs or Replaments 1992-A92

6. Identfication ofComponents Repaired or Replaced and Replacement Componeat Name of Name of M&Wtidu Year Bu R lared Code Compond Maluracturer Serial No. National Oterldentication Replced, or Smped Board No. Repe (ITS or WwkOrderlEqDlpl . NO)

TmUs S1 Horton Contrc# 6-2968 NA CWOAS0471 I g1m 59.00 171 Repaked No (Pimaly Mt. By

)outament) Ccago, Ridge hro n

- - C C - -

7. Deaito f Wor Repaired Torms "s area by remova of arc trikes left y mle we attac en
8. Tests Conducted: Rydrostatc [ Puematic M Nominal OpetgPre El Oae ED Pressure N/A psi Test Temp NIA °F NOTE: Supplemetal eets in form f lists d es, ordawings may be used, prided (I) size is 8112 i x 11 iL, (2) information in items I though 6 on this report Is included on each sheet, and (3) each sheet is umbere and the nuber of sheets is recorded at the top of this form.

(12/82) This Form (300030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New Yo&, NY 10017.

Part G Page 4 of 68 FORMNIS-2 1802-01 FORM NIS-2 (Back)

9. Remarks. Dng an IWE visual examination (P01078) of Ihe torus exterior shell bay #2. arc strikes were note. R t arc strikes were actually temool attachment locations Are strike indications were reove with a flapper wheel Shell thickness was verified after blend gtmi Groud area also received Mr and visu examinatons. Thickness checks and examinadon results were satisfqct .

CERIFICATE 01 COMPLIANCE We certify that t statem made in fte report ae conect and this Rep&

(repair or rpacement) conforms to t rules of t ABE Code, Sction XL Type Code Symbol Stamp _ None Certificate ofAuthrztion No, None ExratfionDat NIA igned (L, Equipment Monitoring Date 4,. / ", 2002 Ownefr Owner's Designee,ile CERTIFICAT 01 INSIRICE SECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pssure Vessel Inspectors and the State or Province of Iowa and employed by MMB Cr of Hartrd. Con=. bave insected the components described in this Owner's Report dring the period Vg-/IZ"O to O dv/da, , and tat to fth best of my knowledge and belief the Owner has performed e and taken corrective measures described in ts Owner's Report m accordance with the requirements of the ASME Code, Section XL By signing this certificate neither he Inspector nor his employer m s any warranty, expressed or implied, concerning the examinations and corective measures described in this Ownes Report Furtherm, neither the Inspector nor his employer shall be liable in any mannr for any personal inury or property damage or a loss of any kind arising from or connected with this inspection Commissions ,IA'X A/S lak InSc s SignarNatioal Board, and Eo s Date Date ,,20/2002

Part G Page 5 of 68 FORM NIS-2 18-02-04 FORM NIS2 OWN'S REPORT FOR REPAIRS OR REPACEMEN As Required by the Provisions ofthe ASME Code Section M

1. Owners Alliant Ener (ES Utlies Date 09/10102 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet I of 2 Address
2. Plant Duane Amold Energy Center Unit I Name 3277 DAEC Road, Palo, IA 52324 CWO A57412 Address Repair Organization to P.0.No,Job No.,etc.
3. Woik Perfoamwd by Nuclear Marnagement Co. LLC Type Code Symbol Stamp None Name Authorization No. NOe 3277 DAEC Road, Palo, IA 5232A Exiration Date None
4. Identification of System M01933, RHR Loop 'B" Torus Spray Header Isolation .
5. (a) Applicable Construction Code *ASM P&V Draft 19 68 Edition Addenda N/A Code Case.

(b) Applicable Edition of Section X Utilized for Repairs or Replacements 222A

6. Identification of Components Repaired or Rephced and Replacement Components
  • Design Secification Bech-MRS-M137 I ~~~~~~~~~~~

Name.r Naeof Manufacturr YearBollt Repaired, Code Component Manukturer Serial No.

IBoard National No.

Other Identilication Werk Order/Equip D Replaced, or Replacement Stamped (YES or NO M01933 RHR Andor Valve 0436-24 N/A CWO A57412 1971 Repaired No opyB Torus Spray Header Isolaton _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7. Description of Work RePlced tack weld between disc and disc mit
8. Tests Conducted Hydrostatic _l Pneumatic M Nominal Operating Pressure Oiier [ Pressure N/A psi Test Tep N/A NOTE: Supplemental sheets in form of lists, sketches, or drawigs may be used, provided (1) size is 8/2 in. x 11 in., (2) information in items through 6 onthis report is included on each sheet and (3) eachsheet is mbered and the mber of sheets is ecorded at the top of this form.

(12182) his Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York NY 10017.

Part G, Page 6 of 68 FORM NIS-2 1B80204 FORM NIS-2 (Back)

9. Remarks: Tack weld locking disc nut to disc was removed to pefom machine work on valve stenL Disc nut tack weld was rplaced using WPS PI-A582-T416AT rev. 0. Both weld procere and Welder were qalified in accoranc with ASME.Section IX Completed weld was visually exammed and found fre ofdefect CERTIICATE OF COMPLIANCE We cere that the statements made in the report are corect and this Repair (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of AuthorizatioviNo. None Expiration Date NA Signed . GLEuip tMoni g Date 'z/c+v /@ 2002 Owner or Owner's Designee, Title CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartfd bave i ecthe components described in this Owneres Report during the period 0: to , and state that to the best of my knowledge and blie£, the OwnCT has performed examinations and taken corrective measures described in this Owner's Report i accordance with the rqements of the ASME Code, Section XL By signig this certificate neither the Inspector nor his employer makes any warranty, exressed or implied, concering the examinations and corrective measures desribed in this Owner's Report. Furthermore, neither the Inspector nor bis employer shall be liable in any manner for any personal ijury or property damage or a loss of any kind arising from or connected vith this inspection.

zr~n~

nsp&tors Signature Commissions &/&I/f7A/LA Cas National Board; State, Pro~,ince, and Endorsements ASi Date

-, F

/0 , 2002

Part G Page 7 of 68 FORM NS-2 18-02-06 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owners Alliant Enerv (S Utites) Date 10/14/02 Name P. O. Box 351, Cedar Rapids, LA 52406 Sheet 1 of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Nam 3277 DAEC Road, Palo, IA 52324 CWOA50455 Address Repair Organization to P. O. No, Job No., etc.
3. Wor Performed by Nuclear Ma nagement Co. LLC Type Code Symbol Stamp None Name AuthoriaionNo. None 3277 DAEC Road, Palo, IA 523224 Expiration Date None
4. Identification of Syste: PSV2102, Core Spray Pump P-21 1A Suction Relief Valve
5. (a) Applicable Construction Code ASME Section M 19 71 Edition S71 Addenda Code Case.

(b) Applicable Edition of Section XI Utilized fio Repairs or Replacements 1992-A92

6. Identification of C ponecnts Repaired or Replaced and Replacement Cononents Name of Name.! Manufacturer Year Ballt Repaired, Code Component Manufacturer Serial No. National Otherldentification Replaced, *r Stanped Board No. Replacement (YES or

._____________ __________ Work Order IEqulp 10 NO )

PSV2102 Andeson N98681BOOOI CWO A504S5 2001 Replaced Yes Greenwood

. ___________ _. C sb y .

7. Description of Work: Replaced relief valve with a new, more reliable modeL
8. Tests Conducted: "Hydrostatic MX Pneumatic [] Nominal Operating Pressure Other F Pressure 5.2 psi Test TWp N/A* °OF
  • NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (I) size is 81t2 in. x lI n., (2) information in items I twrough 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
  • 9nservice functional pressure test, temperature is not required.

"Subjected to manufacturer's hydro test at 425 Psig.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St, New York, NY 10017.

Part G Page 8 of 68 FORM NIS-2 18-02-06 FORM NIS-2 (Back)

9. Remarks: Valve was Mplaced due to a history of nsatisfactory testin pe ance. ReMlaced with newer model desi for the service this valve would apeaience. New valve was built to ASM3 Section m 1986 Edition .No Addenda. and was reconciled to original construction code using Bech-MRS 4M460 Rev. 2. Inservice functional leak test (P2003 was nerfonned satisfactorily after installation.

CERTIFICATE OF COMPULANCE We certi that the statements made in the report are correct and ts Rplacement (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp NA Certificate of Authorization No. NA Epiraion Date NA Stood w GL Equitent Monitoring Date A/n A" 20, 2002 Ownefor Owne's Designee, Title I CERTIFICATZ OF INSERVICE INSPECTION I, the undersignod, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartfod, Comm have inspected the components described in this Owner's Report during the period 0-a-/,a to _ //- __ _ _ _ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By sigong this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions (VP) 19,30,4,yvz /yq, _zi Inspector's Signature National Board, State, Province, and Endorsements Date /- ,.2002 2002

Part G Page 9 of 68 FORMNIS-2 13-03 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPIACEMENTS As Rquired by the Provisions of the ASME Code Section Xl

1. Owners AliMaEnervg ES Utities) Date 4/16103 Name P. O. Box 351, CedarRapids, IA 52406 Sheet 1 of 2 Address
2. Plant Duane Anold Energy Center Unit I Name 3277 DAEC Road, Palo, LA 52324 PWO 1119896 Address Rpair Organztion P. O. No, Job No, etc.
3. Work Pcrformed by Nuclear Ma maaement Co. LC Type Code Symbol Stamp None Name AuthorizationNo. None

. 3277 DAEC Road, Palo, LA 523 24 ExpirationDate None

4. Identification of System: RHR Pump P-220B Torus Suction Line Snubber (HBB-023 -SS-220)
5. (a) Applicable Construction Code *ANSIB31.7 19 69 Edition 71 Addenda N/A Code Case.

(b) Applicable Edition ofSection X ltilized for Repairs or Replacments 1992-A92

6. Identification of Components Repaired or Replaced and Replacement Components
  • Design Specification Bech-MRS-1 19 Name.r Name *f anufacturer YearBalt Repaired, Code Component Manufacturer Seral No. National Otherldentlfication Replaced, or Stomped Board No. Replacement (YES or

.____________ ___________ _____________ W orkOrder/Equip ID NO)

RHRPump IP- Belven DA-065 (DAEC NA wO 1119S96 M/A Replaced 220B Tos 'Paters. as ed)

Sucon le Snubber_ ____

i jI -- I 1--

J 1- --- -

.9 4. 9. 4. 4. .9 1-

.9 9. 4. 4. *9 3 a a .

7. Description of Wok: Replaced snuber DA-066 with rebuilt snMber DA-065.
8. Tests Conducte& *Hydrostatic E Pneumatic E Nominal Operatig Pressure El Other Pressure N/A Psi Test Temp N/A °F NOTE: Supplemental shects informoflists, skhes, ordrawi maybe used, provided (I) size is 81/2 z 11 in, (2) information in items I through 6 on this report is inchlded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part G Page 10 of 68 FORM NIS-2 03-03 FORM NIS-2 (Back)

9. Remarks: Snubber DA-066 located at HBB-023-SS-220 showed sliht siens of leakage. Alhough DA-066 passedvisual

& functional test criteria, a rebuilt snubber DA-06) was mnstalled The rebuild of DA-065 retuid onily seals

& fluid (no load bearing parts were Wplaced) A pre-service VT-3 IP03012) was comleted following installation.

CERTIFICATE OF COB1PLANCE We certify that the statments made in the report are correct and this Replacement (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. - None Expiration Date NA Signed .Equipment Reliability Date 02 / I I /4' 2003 Owner olOwner's Designee, Title I.

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressur Vessel spectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components descbed in tids Owner's Report during the period A a to Sf-?- 03 _ , and state that to e best of my knowledge and belieft the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the reqiemns of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, pressed or implied, concerning the examinations and corrective measures described in this Ovwer's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NV )o3a qdt r , a Y96r Inspector's Signature National Board, State, Province. and Endorsements Date '1-7-0 3 , 2003

Part G Page 11 of 68 FORM NIS-2 18-3-05 FORM NS-2 OWN'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owners Alliant Enera (IS Ules Date 4/18103 Name P. 0. Box 351, CodaRapids, IA 52406 Sheet 1 of 2 Address
2. Plant Duane Arnold Energy Center unit I

- Name 3277 DAEC Road, Palo, IA 52324 CWO A62304 Address Repair Organization to P. O. No, Job No., etc.

3. WodcPerfbrmedbyNucearMa nagement Co. LLC Type Code Symbol Stamp None

-Name Authorization No. Nohe 3277 DAEC Road, Palo, IA 523; 2 Expiation Date None

4. Identification of System: Reactor Feedwater Inlet Header Snubber (DLA402-SS-006)
5. (a) Applicable Construction Code OASMEINF 19 74 Edition W76 Addenda NJA Code Cse.

(b) Applicable Edition ofSection Xl Utilized for Repairs or Replacements 1222A2

6. Identification of Components Repaired or Replaced and Replacement Components Design Specification Bech-hS-M227 I ~~~~~~~~~~~~

Name of Name of Manufactarer Year Built Repaired, Code Component Manufacturer Serial No. National Other Identification Replaced, or Stumped Board No. Replacement (YES or WorkOrderlEquip D NO)

Reactor Usega 016151231061 MA CWO A62304 DA-002--006 2001 Replacement No Feedwater Inlet Header Snubber

7. Description ofWork: Replaced snubber, DLAO -SS-006, with new LIsega snubber SIN 01615123/061.
8. Tests Conducted: Hydrostatic [] Pneumatic [-] Nominal Operating Pressure El Other [ Pressure N/A Psi TestTemp N/A OF NOTE: Supplemental heets in form oflists, sketches, or drawings maybe used, provided(I) size is 8112 in 11 im, (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, NY 10017.

Part G Page 12 of 68 FORM NIS-2 18 0305 FORM NIS-2 (Back)

9. Remarks: Origina snubber. S/N 97614263/08. developec fluid leak fiom loose fluid sitejlass. nstalled new Lisuga snubber. SIN 01615123/061. at location DLA- -SS-006. stalled snubber was subjected to a functional test prior to installation and a pro-service VT-3 (P03041) followina installation.

CERTIFICATE OF COMIPIANCE We ceri that the statements made in the report are correct and this ement (repair or replacement) conforns to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. None Expiration Date NA Signed EqipmentReliabili Date 2 / 2003 Owner sOwner's Designee, Tide CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inpetors and the State or Province of Iowa and employedby HSB Cr of Htford, Conn. have inspected the components described in this Owners Report daringtbeperiod 4-6o- O to y 19-O 3 , andcstate thatto thebestof my knowledge and belief the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements ofthe ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descbed in this Owner's Report Furthermore, neither the Inpector nor his employer shall be liable inany manner for any personal nury or property damage or a loss of any kind arising fiom or connected with this inspection.

) 4 - Commissions i?3*?-,V ?V9, / '9 Inspector's Signature National Board, State, Provinmce, and Endorsements Date _ - _ _ _ _ ,2003

Part G, Page 13 of 68 FORM NIS-2 18-03-07 FORM NIS-2 OWNER'S REPORT FOR REPAIERS OR REPIACEMENTS As Required by the Provisions of die ASME Code Section Xl

1. Owners Alliant Enr (lES Utilities Date 4119/03 Name P. 0. Box 351, CedarRapids, LA 52406 Sheet 1 of 2 Address
2. Plant Duane Arnold Energy Center unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1119897 Address Repair Organiztion to P.O. No., Job No., etc.
3. WorkPerformed by NuclearMa na tz Co. LLC Type Code Symbol Stamp None Name AuthorizationNo. None 3277 DAEC Road, Palo, IA 523224 , Expiration Date None
4. Idenffction of System: RHR Pump 1P-220B/D Tons Suction Lie Snubber (HBB-023-SS-219)

S. (a) Applicable Construction Code ANSI B31.7 19 69 Edition 71 Addenda N/A Code Case.

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1992A92

6. Idnification of Component Repaired or Replaced and Replacement Components Design S =fication Bech-MS-l 19 l Name Name of Manufacturer YearBult Repahrd Code Component Manucturer Serial No. National Other dentification Replaced, or Stmped

. .. Board No. Replacement (YES or WorkOrderlEquip ID NO)

RHR Piup IP- Balen DA4033 (DAEC N/A PWO 11 19897 BB023-SS-219 M/A Replacement No 220BJD Tous .Pton. assied)

Sucion Line Snubber

7. Description of Work Replaced snubber DA-359 with rebuilt snubber DA-033.
8. Tests Conducted: *Hydmfttic C1 Pneumatic [ Nominal Operating Pressure ci Other [] Pressure N/A Psi Test Temp NIA °F NOTE: Supplemental sheets in form of lists, dstches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 thmugh 6 on this report is included on each sheet, and (3) each sheet is nmbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, NY 10017.

Part G, Page 14 of 68 FORM NIS-2 18-03-07 FORM NIS-2 (Back)

9. Remarks: Snubber DA-359 located at HBB-03-SS-219 failed as-found fimctional test criteria. A rebuilt snubber (DA-033) was installed be rebuild of DA-033 renired only seals & fluid (no load bearing parts were renlaced) re-service VT-3 (PQ3013) was comoleted followin installation.

CERTICATE OF COMPLICE We certify that the statements made in the report are carect and this Replacement (repair or replacement)

COMS to the miles of the ASNE Code, Section XL Type Code Symbol Stamp None Certificate ofAuthorization No. None Expiration Date NA Signed ev/4*~ . Equipment Reliabili Date 6 AC% /9, 2003 Own Designee, Title CERTMIICATE, OF INSERVICE INSPECION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by S Cr of Hartford, Con have inspected the components described in this Owne's Report duringtheperiod //-5-6 to y ,and state thatto thebestof my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section X.

By signing this certificate neithter the Inspector nor his employer maes any warranty, exressed or malied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal ijury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _1__ - Commissions IVPd 5 4v 9,!% & /Y6 Inspectoes Signature National Board, State, Province, and Endorsements

_ l

,2003

Part G, Page 15 of 68 FORM NIS-2 18-03-08 FORM NIS-2 OVNER'S REPORT FOR REPAIRS OR REPLACEMEJS As Required by the Provisions of the ASME Code Section Xl Owner Allit En e Lties) Date - 423/2003 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet 1 of 2 Address

2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1123629 Address Repair Organization to P. O. No., Job No., etc.
3. Work Performed by Nuclear Ma nagement Co. LLC Type Code Symbol Stanp None Name AuthorizationNo. None 3277 DAEC Road, Palo, IA 523124 EVpration Date None
4. Identification of System: Control Rod Drive Accumulator - Class 2
5. (a) Applicable Constuction Code ASME VM 19 68 Edition
  • Addenda. Code Caw.

(b) Applicable Edition of Section Xl Utilized for Rars or Replacents 1 -A92 2

6. Identifcaon or xs eparrec or xace and ee n Mponext Name f Name of Manufacthrer Ye"rBalt Repaird, code Component Mnufactrer Serial No. National Board No. Other Identification Replaced, or Stamped Replacement (YES or 2 ~~~~~~~~~~~

( n General Electric SIN C004 NA lS220 (107) 1978 YS YEplacement

~Accumulator _ _ _ _ _ _ _ _

'm _ __

7. Description of Work:
8. Tests Conducted Hydrostatic [-1 Pneumatic [] Nominal Operating Pressure I I Other [] Pressu 1020 psi Test Temp 210 °F NOTE: Spplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 81/2 in. x 11 in., (2) infmation in items 1 through 6 on this report is inchlded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form (12/82) This Form (E00030) may be obtained fiom the Order Dept, ASME, 345 E. 47th St, New York NY 10017.

Part G, Page 16 of 68 FORM NIS-2 1803Q08 FORM NIS-2 (Back)

9. Remarks: Replaced accumulator SIN 6576335 with S/N C0004, which is an improved design, Replaced accumlator Replaced accumulator will not be reused. A VT-2 (ref 103001) was completed and ce3 d CERTIICATE OF COMPLLNCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. None Expiration Date N/A Signed TLEquipmentReliabity Date 4pJ P E34 2003

-Owner or`Owner's Designee, Tide CERTHICATE OF INSERVICE INSFECION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB Cr of Hartford Conn have inspected the components described in this Owne's Report during the period _ 3_ /a- to _ _ _ _ _ _ , and state that to the best of my knowledge and belief the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate nether the Inspector nor his employer makes any warranty, exressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind ansing from or connected with this inspection.

_________________ Commissions QV i l'I'k 9, .Zs Inspector's Signature Naional Board, State, Province, and Endorsements Date W-a!q. , 2003 2003 Date L/

Part G, Page 17 of 68 FORM NIS-2 18-03-09 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owners Alant Enerfl (ES UtLies) Date 0428/03 Name P.O. Box 351, Cedar Rapids, IA 52406 Sheet 1 of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1125013 Addres Repair Organization to P. . No., Job No., etc.
3. Wodc Pcrfonred bjNuclear Management Co. LLC Type Code Symbol Stamp None Name AuthorizationNo. None 3277 DAEC Road, Palo, IA 52324 Expiration Date None
4. Identification ofSystem: Stand-by Liquid Control System
5. (a) Applicable Construction Code ASME, Section M 19 77 Edition S77 Addenda N/A Code Case.

(b) Applicable Ediion of Section Xl Utilized for Repars or Replacements 1992&A2

6. .Identification of enpaired or Replaced and Replacement Components Name of Name of Manufacturer YearBunft Repaired, AS E Component Manufacturer Serial No. National Other Identification Replaced, or Stamped Board No. Replacement (YES or WorkOrder/Equlp ID NO)

SBLC Squib Vave IST Conax 1529 A WO 1125013 I XS261SA 2003 Replaced No Nuclear

7. Descrton of Wek: Installed Explosive actuated kit assembly.

B. Tests Conductd: Hydrostatic E Pneumatic El Nominal Operating Presswre OtherEZ Pressure 1240 psi Tcst Tcnp N/A °F NOTE: Supplemental sheets m form of lists, sketches, or daswings may be used, provided (1) size is 81/2 in. x 11 in., (2) infomation in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (EO0030) may be obtained from the Order Dcpt, ASME, 345 E. 47th St, New Yor, NY 10017.

Part G, Page 18 of 68 FORM NIS-2 18-03-09 FORM NIS-2 (Back)

9. Remak: Following actuation test of Sqmb valve XS2618A. a new replacement valve kit was installed. no.kit included triger assiblv. pri chamber. and inlet fitting. Installed kt was pressure testod on STP 3.1.702 (P03033).

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report ae correct and this Replacement (repair or replacement) confoms to the rules of the ASME Code, Section Xl.

Type Code Symbol Statp None Certificate ofAuthorizat! No. None Expiration Date N/A Signed GL Eqqudpt Monitorng Date / 2003 S dOwner or er's Designee, Title aJ I.

CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, ComL have inpected the components described in this Owner's Report during the period 3-ZA--62 to c_ - -_ _ , and state that to the bt of my knowledge and belief; the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descnbed in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

- Inspector's Signature National Board, State, Province, and Endorsements Date S- -  : ,2003

Part G, Page 19 of 68 FORM NIS-2 18-03-10 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENIS As Required by the Provisions of the ASME Code Section XI

1. Owners Alliant Energy (ES1Ulities) Date 4/27/2003 Name P. 0. Box 351, Cedar Rapids, IA 52406 Sheet I of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA52324 PWO 1123631 Address Repair Organization to P. O. No., Job No, etc.
3. WorkPerformedbyNuclearMa agement Co. LLC Type Code Symbol Stamp None Name Authorization No. None 3277 DAEC Road, Palo, LA 523:24 Expiration Date None
4. Identification of System: Control Rod Drive Accumulator - Class 2
5. (a) Appicable Construction Code ASME VIII 19 68 Edition Addenda Code Case.

(b)Applicable Edition of Section XI Utilized for Repairs orRplace 1992-A92 6.

Idenntcaunon o aneRorpaomp 1aced and Replacement oMponntS Name f NAe of Manufacturer Year Bult Repaired, Code Component Manufacturer Serial No. National Board No. Other Identification Replaced, or Stamped

. eneral Electri c S/ N H2940 N/ A 1S220 ( 22- l ) 1980 Re pl cm n t ( No r tCR Gkera Eledric S(N H2940 NIA IS220 (22-1 1) 1980 Rcpacant YES

7. Description of Work: CRD Accumulator was replaced.
8. Tests Conducted& Hydrostatic [] Pneumatic M Nominal Operating Pressure Other [] Pressure 1020 psi Test Temp 210 NOTE: Supplemental sheets in form of lists, sitches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) Tlhis Form (E00030) may be obtaned fom the Order Dept., ASME, 345 E. 47t St., New Yorkl NY 10017.

Part G Page 20 of 68 FORM NIS-2 18-310 FORM NIS-2 (Back)

9. Remarks: Relaced accumulator S/N 6576410 with spare SN H2940. which is an imroved desiz. ,4 Replaced accumulator will not be reused. A VT-2 (ref 103001) was completed and accerted.

CERTIFICATE OF COMAPLANCE We cey that the statements made in the report are correct and bis replacement (repair or replacement) conforms to the rules of the ASM Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. None Expiration Date N/A Signed /,..-<STL Equipment Reliability Date 10 Z8, i _ _^~ -

2003

  • 0i76or&lwner's Designe. Title CERTIFICATE OF INSERVICE INSPECTION I II-

, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of of Hartford, Cornm Iowa and employed by HSB Cr have inspected the components described in this Owner's Report K

during the period 3-i/- p3 to _ _

_-_ _ -_ 3 , and state 1hat to the best of my knowledge and belief, the Owner has performed examnations and taken corrective measures describd in this Owner's Report in accordance with the requirments of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the.

examinations and correcive measures descnbed in this Owner's Report. Furtfermore, neite the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fiom or connected with fis inspection.

Commissions /VA 1.13 D9,4.

Inspector's Signature National Board, State, Province, and Endorsements Date q -4 A , 2003 2 3

Part G, Page 21 of 68 FORM NIS-2 18-03-11 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions ofthe ASME Code Section XI

1. Owners Allant Enerev (ES Utlities) Date 4J2812003 Name P. 0.Box351, CedarRapids, IA 52406 Sheet 1 of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, LA 52324 PWO 1123638 Address Repair Organiation to P. O. No., Job No., etc.
3. Work Performed byNuclear Ma nagement Co. LLC Type Code Symbol Stap None Name Auhorization No. None 3277 DAEC Road, Palo, IA 523124 ExpirationDate None
4. Identification of System Control Rod Drive Accumulator - Class 2
5. (a) Applicable Construction Code ASM VI 19 68 Edition Addenda Code Case.

(b) Applicable Edition of Section XI Utilized for Repairs or Replacemnents 1992-A92

6. idenmcaUon or Cteured o Rc aced and Replacen? Components ASMdE Nme of - 'Nme o Manufacturer Year unt Repaired, Code Component Manufacturer Serial No. National Board No. Other Identification Replaced, or Stamped Replacement (ES or CRD. Gencrd Electric SIN C040 N/A 1S220 (34-11) 1975 Replaement YES Amlator __
7. Description of Work CRD Accumulator was replaced.
8. Tests CAnduct& Hydrostatic [] Pneumatic [] Nominal Operating Pressure Other [I Pressure 1020 psi Test Temp 210 NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 81/ inL x 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St, New York, NY 10017.

Part G, Page 22 of 68 FORM NIS-2 1803-1 FORM NIS-2 (Back)

9. Remarks: Replaced accumulator SIN 6576404 with spare SIN C0040, which is an improved design.

Replaced accumulator will not be reused. A VT-2 (ref 103001) was comieted and accepted.

CERTIICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to fie rules of the ASM3 Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. None Exiration Date N/A Signed TL Equiment Reliability Date 2003

'Owner of Ownes Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel InEspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conm. have inspected the componens described in this Owner's Report during theperiod ____Solo ___to LIg- c3 ,and state that to fetbest of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the reqirements of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer mkes any warranty, expressed or implied, concerning the exainations and corrective measures described in this Owners Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inury or property damage or a loss of any kind arsing from or connected with this inspection.

Commissions ,VCoos, , / W&

Inspeco's Signature National Board, State, Province, and Endorsements

, 2003

Part G, Page 23 of 68 FORM NIS-2 18-03-12 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPIACEMENTS As Rmffired by the Provisions of the ASME Code Section I

1. Owners Alliant EnerWv (ElS UiMLes) Dae 4/282003 Name P. 0. Box 351, CedarRapids, IA 52406 Sheet I of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, 1A 52324 PWO 1123636 Address Repair Organization to P. O. No, Job No, etc.
3. Work Perfonmed by Nuclear Mi anagement Co. LLC Type Code Symbol Stamp None Name Audoization No. None 3277 DAOC Road, Palo, IA 523;24 ExpirationDate None
4. Identification of System - Contiol Rod Drive Accumulator - Cass 2
5. (a) Applicable Construion Code AME VlII 19 68 Edidon Addenda Code Case (b) Applicable Edition of Section X Utilized for Repairs or Replacements 12-A2
6. Identification of Co ont Repaned or Re laced and Replacement Components

'Name of - .rName of I Manufadurer Year Bult Repaired,

~~~~~~~~~~~

Code Component Manufacturer Serial No. National Board No. Other Identificatlon Replced, or Stamped Replacement (YES or CRD Geneal Electric SIN C0070 NIA IS220 (10-31) 1978 Replacment YES Accumulator

7. Description of Work
8. Tests Conducted Hydrostatic [] Pneumatic [] Nominal Operating Pressure OtherM Pressure 1020 psi Test Temp 210 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 hrough 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form(E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, NY 10017.

Part G Page 24 of 68 FORM NIS-2 18-03-12 FORM NIS-2 (Back)

9. Remarks: Replaced accumulator SIN 6576357 with spare SIN C0070, which is an improved design.

Replaced accumulator will not be reused. A VT-2 (ref 103001) was completed and accepted CERTFCATE OF CODULANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the nles of the ASME Code, Section Xl Type Code Symbol Stamp None Certificate of Auth Expiration Date N/A Signed Date 7 --

cI

-- -I 2003

'I r L I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB Cr of Hartford, Comi. have inspected the components described in this Owner's Report during the period 3-/1- O3 To ___ __ __ 3 __ _ _ ,and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requiremts ofthe ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal ijury or property damage or a loss of any kiDnd arising from or connected with this ispection.

Commissions /V2S Q, jkqv =

inspectoes Signatiire National Board, State, Province, and Endorsements Date Y 2003

, 2003

Part G Page 25 of 68 FORM NIS-2 18-03-13 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owners Aiant Ener (IES Uilities) Date 4/t2003 Name P. O. Box 351, CedarRapids, IA 52406 Sheet 1 of 2 Address
2. Plant Duane Amold Energy Center Unit I Name 3277 DAEC Road, Palo, IA 52324 PWO 1123635 Address Repair Organization to P. O. No Job No, etc.
3. Work Performed by Nuclear Mmnagement Co. LLC Type Code Symbol Stp None Name AudhorizationNo. None 3277 DAEC Road, Palo, IA 523 4 ExpiraonDate None
4. Identification of System: Control Rod Drive Accumulator - Class 2 S. (a) Applicable Construction Code ASMEVM 19 68 Edilion Addenda . Code Case.

(b) Applicable Edition of Section XT Utilized for Repairs or Rp 1992-A92

6. Identification of Repaied or Rq laced and Reacem Components __ _

ASME

  • -, -Name f --- Name r Manufacturer Year Bit Repalred, Code Component Manufacturer Serial No. National Board No. Other Identification Replaced, *r Stanped Replacement (YES or CRD General Electic S/N 0061 1UA 1S220(10-11) 1978 Replacement YES Ac mu lator _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7. Description of Wok
8. Tests Condcted.- Hydrostatic [] Pneumatic [] Nominal Operating Pressure other LI Pressure 1020 psi Test Temp 210 °F NOTE: Supplemental sheets inform oflists, sketches, or drawings maybe used, provided (1) size is 81t2 in x 11 in., (2) information in items I trough 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form (12/82) This Form (E00030) may be obtained fiom the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part G Page 26 of 68 FORM NIS-2 1803-13 FORM NIS-2 (Back)

9. Remarks: Replaced accumulator SIN 6576356 with spare S/N C0061, which is an imved desigXL Relaced accumulator will not be rused. A VT-2 (ref 103001) was conmieted and accpedA CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair orreplacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. None Expiration Date N/A Signed or TL uipment Reliabilkr Dat A pD n I 2003

' Owner or (0wnees8 Designee4 Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and .

the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components described in this Owner's Report duringthe period --1 2 . To _ Y__7

_ _ _ _ _ , and state that to the best of my knowledge and belief, the Owner has performed examnations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind aising from or connected with this inspection.

2) V---- Commissions AX ) 3,)?o9 .41 / ,f9 .Z2 Inspector's Signature National Board, State, Province, and Endorsements Date 00q

, 2003

Part G Page 27 of 68 FORM NIS-2 18-03-14 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASM Code Section XM

1. Owners Aiant Enerv (ES Utilities) Date 4r2&2003 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet 1 of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1123637 Address Repair Oanization to P. . No., Job No. etc.
3. Work Performed by Nuclear Mi mae~ment Co. LLC Type Code Symbol Stmp None Name Authorization No. None 3277 DAEC Road, Palo, IA 523 24 ExpationDate None
4. Intification of System Control Rod Drive Accumulator- Class 2
5. (a) Applicable Constuction Code . ASMVI 19 68 Edition Addenda:.._____ Code Case.

(b) Applicable Edition of Section X Utized for Repairs orReplacements 1992-A92 r

6. idenuncaon 01 iepaired Ronens or aced and epaceme Lomponents ASME Name of Name *f Manufacturer YearBallt Repaired, Code Component Manufacturer Serial No. National Board No. Other Identification Replaced or Stamped Replacement (E or CRD General Electric SIN H2859 NA IS220 30-19) 1980 Replacement NES Accumlntor
7. Description of Work: CRD Accumulator was replaced.
8. Tests Conducted: Hydrostatic [] Pneumatic [] Nominal Operating Pr=ssure R Other-L Pressure 1020 psi Test Temp 210 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 81/2 in. x 11 in., (2) information in items I hrough 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top ofthis forn.

(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, NY 10017.

Part G, Page 28 of 68 FORM NIS-2 18-03-14 FORM NIS-2 (Back)

9. Remarks: Replaced accumulator SIN 6576387 with spare SIN H2859, which is an improved design. _

Replaced accumulator will not be reused. A VT-2 (ref 103001) was comuleted and accept CERTIFICATE OF COMPLIANCE We cerfy that the statements made in the report are correct and this replacement (repar or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. None Expiration Date NA Signed TL quipment Reliability Date A 2% ,

2003 Owndf or Owner's Designee, Title e

CERTIICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel lispectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components described in this Owner's Report during the permiod  %- - _3 To _ _ __ 's _ , and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures descnbed in this Owner's Report in accordance with the requirements of the ASM Code, Section XL By signng this certificate neither lhe Inspector nor his employer makes any wanany, expressed or implied, concerning the examinations and corrective measures descrilbed in this Owner's ReporL Furthermore, neither the Inspector nor his employer shall be liable in any mamer for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions L18 J2S;)t?4A1X / /.q f2 Lt~

Inspector's Signature National Board, State, Province, and Endorsements Date 4-2q-o ,,02003

Part G Page 29 of 68 FORM NIS-2 18-03-15 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section X1

1. Ownas Alant Enezy (S UAes Date 4/2812003

. Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet 1 of 2 Address

2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1123633 Address Repair Organization to P. O. No, Job No., etc.
3. Work Perfomed by Nuclear Ma magement Co. LLC Type Code Symbol Stamp None Name Aufhorization No. None 3277 DAEC Road, Palo, IA 523; 24 ExpirationDate None
4. Identification of System: Control Rod Drive Accumulator- Class 2 -
5. (a) Applicable Construction Code -ASME;VI 19 68 Edition _ Addenda _ Code Case.

(b) Applicable Edition of Section X Utilized for Repairs or Replacements 1992-A92

6. Identffication Of Reaire d or q daced and Replac t Components

-Name of Manufacturer Year Built Repaired, Code Component Mannfacturer Serial No. National Board No. 4ther Identification Replaced, or Stamped Replacement (YES or CRD Genond Electric S/N N3159 NA IS220 19BO Rep t YESN6)27)

Accunmintor ._

7. Description ofWor CRD Accumulator was replaced.
8. Tests Conductedt Hydrostatic [ Pneumatic [] Nominal Operating Pressure Other El Pressure 1020 psi Test Temp 210 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in, (2) information in items 1 through 6 on this report is included on each sheet%and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part G, Page 30 of 68 FORM NIS-2 18-03-15 FORM NIS-2 (Back)

9. Remarks: Replaced accumulator SIN 6576432 with spare SIN m3159, which is an improved design Replaced acumulator wil not be reused. A V_-2 (ref 103001l was combleted and accepted.

CERIFICATE OF COMPLLANCE We certify that the statements made in the report are correct and this rep t (rpair or replacement) conform to the rules of the ASNIE Code, Section XL Type Code Symbol Stamp None Certificate of A No. None Expiration Date N/A Signed 0-we 1

Designee, 8Vwne Rei Title Date A1 2J 2 2003 the State or Province of CERTIFICATE OF INSERVICE INSPECTION I, he undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and Iowa and employed by HSB CT I

of Hartord, Conn. have inspected the components described in this Owner's Report ding the period ?y-ha O To __ _ __ 3_ . , and statethat to the best of my knowledge and belief, the Owner has pcrformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing hids certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions WP% 1fl31.9"Al -r It/#c., -

Inspector's Signature National Board, State, Province, and Endorsements Date 4 - , 2003 200

Part G, Page 31 of 68 FORM NIS-2 18-03-16 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMNTS As Required by the Provisions of the ASE Code Section XI

1. Owners - iantEner (IESUtilities Date 428t2003 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet 1 of 2 Address
2. Plant IDuane Arnold Energy Centfr Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1123630 Address Repair O iZation to P. O. No Job No, et.
3. Work Performed by Nuclear Mmmagement Co. LLC Type Code Symbol Stamp None Name Authorization No. None 3277 DAEC Road, Palo, IA 523224 Expiration Date None
4. Identification of Syste: . Control Rod Drive Accumulator- Class 2
5. (a) Applicable Construction Code ASM V E 19 68 Edition _,- Addenda

_ :____ Code Case.

(b) Applicable Edition of Section X Utilized for Repairs or Replacements 1992-2

6. Identification of Componets R ed or R daced l and Rpl nt Components

-Nameof --- Nameof Manufacturer YearBuit Repar Code Component hnnfacturer Serial No. National Board No. Other Identification Replaced, or Stamped

. Replacement (YES or CRD 1edric SINC0010 VA220 18nera (06-19) 1978 Replacement YES Accmulator

7. Descriptionof Work:
8. Tests Conducted: Hydrostatic [] Pneumatic _ Nominal Operating Pressure n1 OtherU- Pressure 1020 psi Test Tenmp 210 °F NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8112 in. x 11 in, (2) information in items I through 6 on tbis report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, NY 10017.

Part G, Page 32 of 68 FORM NIS-2 18-03-16 FORM NIS-2 (Back)

9. Remarks: Replaced accumulator SIN 6576362 with spare SiN CO0010, which is an improved design.

Replaced accumulator will not be reused. A VT-2 (ref 103001 was comileted and ted.

CERTIF[CATE OF COMPLIANCE We certify that the statements made in the report are correct and hids replacement (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Autho tNo. None Exiration Date N/A Signed dJSC. XA- W, T ETuipment Reliability Date ns Z 2003 Owner otbwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB Cr of Harod, Con have insected the components described in this Owner's Report during the period 3- } - o3 To _ ____ ___ ___ _ _ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with th requirements ofthe ASME Code, Section EL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examiations and corrective measures described in this Owner's Repor Furthermore, neitlier the Inpector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A/f?, j5D3q4A,i. / IL/ 9 /I Inspector's Signature National Board, State, Province, and Endorsements Date L - ;9q -200 , 2003

Part G Page 33 of 68 FORM NIS-2 18-03-17 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of he ASME Code Section Xl

1. Owners Alliant Ener lES Utilites) Date 4/28/2003 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet 1 of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1123632 Address Repair OManization to P. O. No., Job No., etc.
3. Worc Performed by Nuclear Ma iagement Co. LLC Type Code Symbol Stamp None Name AuthorizationNo. None 3277 DAEC Road, Palo, L 523 24 Epiration Dat None
4. Identification of System Confrol Rod Drive Accumator- Class 2
5. (a) Applicable Construction Code ASMEMV 19 68 Edition Addenda Code Case.

(b) Applicable Edition ofSection XI Utilized for Repairs or Replacements 1992-A92

a. aelnuncauon or zepaired or Kg lacea anaeplacemt L n N of ---Name of Manufacturer Yearlnlt Repaire Code Component Manufacturer Seril No. National Board No. Other Identification Repbeed, er Stsmped I ~~~~~~~~~~~~~~~~~~~~~~

(YE or

. Ge.a lcri / 01 NO)

CRD Electk SIN CD017 N/

WA IS220 (22-23) 1978 Replacement YES Accmulator .

7. Description of Work
8. Tests Conducted: Hydrostatic E] Pneumatic ] Nominal Operating Pressure

- Other l: 1020 psi Test Temp 210 eF NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 81/2 in. x 11 in, (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this fonn.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St, New York, NY 10017.

Part G, Page 34 of 68 FORM NIS 2 8-03-17 FORM NIS-2 (Back)

9. Remarks: Replaced accumulator SIN 6576347 with spare SIN C0017, which is an improved design.

Replaced accumulator will not be reused, A VT-2 (ref 103001) was completed and acceptd CERTIFCATE OF COMPLIANCE We certify that the statements made in the report ae correct and this replacement (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. None Expiration Date N/A Signed _ThEqupmnt Relability Date 4 r.g lT 2003

'Owner or Ov~er's Designee, Title CERTMCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Con. have inspected the components described in this Owner's Report during the period 3-,)-- o To t/ )q- 3 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describd in this Owner's Report in accordance with the reirements of the ASME Code,Section X By signing this cerificate.neither the Ispector nor his employer mkes any wananty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind aising from or connected with this inspection.

Commissions AJA QYVqAAI-r IYQA6 -2V Inspector's Signature National Board, State, Province, and Endorsements Date q-dcV ' , 2003

Part G Page 35 of 68 FORMNIS-2 18-03-18 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owners Aiant Em OESUes Date 428i2003 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet I of 2 Address
2. Plant Duane Arnold Energy Center Unit I Name 3277 DAEC Road, Palo, IA 52324 PWO 1123634 Address Repair Organization to P. . No., Job No, etc.
3. Work Performed by Nuclear Mamagement Co. LLC Type Code Symbol Stamp None Name AufhoriationNo. None 3277 DAEC Road, Palo, IA 523 24 Expiration Date None
4. Identification of Systemr Control Rod Drive Accumulator- Class 2
5. (a) Applicable Construction Code. ASME VIII 19 68 Edition Addenda ____ CodeCase.

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992-A92

6. laenancanon ox o Rpaired or Kq 1racea am epacenm omponenTs .

Name*r - Ne.r Manufacturer Year Bunt Rqah, Code Component Manufacturer Seral No. National Board No. Other Identification Replaced, or Stamped Replacement (YES or CRD Generl Electric SIN C0031 NA 1S220 (10.07) 1978 Replacement YES Accurnulator _

7. Description of Work: CRD Accunmator was replaced.
8. Tests Conducted. Hydrostatic _ Pneumatic E] Nominal Operating Pressure OtherF] Pressure 1020 psi Test Temp 210 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8m2 in. x 11 in., (2) information in items 1 tirough 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) maybe obtained from the Order Dept., ASME, 345 E. 47th St, New York, NY 10017.

Part G Page 36 of 68 FORM NIS-2 Q3-1 8 FORM NIS-2 (Back)

9. Remarks: Replaced accumlator SIN 6576340 with spare SIN C0031, which is an iwproved design.

Reiaced accumulator will not be reused. A VT-2 (ref 103001) was completed and accepted.

CERTiFICATE OF COMPLANCE We cerii that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp None Certificate of Authorization No. None Expiration Date N/A Signed T' Equipment Reliability Date 4 n 27. 2003 Owner& Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components described in this Owner's Report during the period 3 la -a 3O

_ ToI-, 9- 6 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descibed in this Owner's Report in accordance with the rqurements of the ASME Code, Section XL By signing this certificate neither the Lpector nor his employer makes any warranty, expressed or implied, concerning the examintions and corrective measures descnbed in this Owner's Report Furthermore, neither the Oispector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions MSz )399,4N-T- AV& 2:; r Inspector's Signature National Board, State, Province, and Endorsements Date _ Q 2003

, 2003

Part G Page 37 of 68 FORM NIS-2 1803-20 FORM NIS-2 OWNER'S REPORT FORREPAIRS OR REPLACEMENIS As Required by the Provisions of the ASME Code Section Xl

1. Owners lliant Energ (ES U es Date 04J28/03 Name P. 0. Box 351, Cedar Rapids, IA 52406 Shed 1 of 2.

Address

2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 CWO A61392 Address Repair Orgmization to P. O. No, Job No, etc.
3. Wo Performed byNuclear Ma nagement Co. LLC Type Code Symbol Stamp None Name AutdoriafionNo. None 3277 DAEC Road, Palo, IA 523; 4 Expiration Date None
4. Identificaion of System: Stand-by Liquid Control System S. (a) Applicable Construon Code ASME, Section M 19 77 Edition S77 Addenda N/A Code Case.

(b) Applicable Edition of Section Xl Uilized for Repairs or Replacements 1992:h22 r

a. £denuicanon or Kepareo or c laced an acement Lomponents Nameof - Nameef Manufacturer YearBult Repalrd, Code Component Manufacturer Serial No. National Other Identification Replaced, or Stamped I. .Board No. Replacement (YES or WorkOrder/Equip ID NO)

SBLC Sqiiib Vilve IST Cna 1530 WXA CWO A61392 I XS2618B 20O3 Replaced No

__N .Ncar

7. Description of Work hIstalled Explosive actuated kit assembly.
8. Tests Conducted: Hydrostatic E Pneumatic [l Nominal Operating Pressure Other [D Pressure 1240 psi Test Temp N/A OF NOTE: Supplemental sheets in form of lists, sketches, or drawngs may bc used, provided (1) size.is 81/2 in x ll in, (2) information in items I through 6 on this report is included on each sheet, and (3) each sbeet is numbered and the number of sheets is recorded at the top of this fomn-(12/82) Ihs Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New Yodr, NY 10017.

Part G Page 38 of 68 FORM NIS-2 18-03-20 FORM NIS-2 (Back)

9. Remarks: Following actuation test of Sqinb valve XS2618B. a new rElpacement valve kit was installedL The kit included triwer assembly. pimer chamber. and inlet fitting. Tnstalled kit wvas e tested on STP 3.1.7402 (P03034).

CERTiFICATE OF COMPLLANCE We certify that the statements made in the report are correct and this Replacement (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp _ None Certificate of Authorization No. None Expiration Date N/A Signed GLEquipmentMonitoring Date Z 3 2003 Ownefor Owners Designee, Title CERTFCATE OF INSERVICE INSPECTON I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesel Inspectors and the State or Province of Iowa and employed by HSB CI of Hartford, Conn. have inspected the components described mithis Owner's Report during the period to°?

to & , and state that to the best of my knowledge and belief, the Owner has perform examinations and taken colrective measures described in this Owner's Report in accordance with the requirements ofthe ASME Code,Section XI.

By signig this certificate neither the Inspector nor his employer makes any warranty, expressed or mplied, concemmg the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal ijury or property damage or a loss of any kind arising fiom or connected with this inspection.

Commissions l 23oar d , a r Ispector's Signature National Board, State, Prbvince, and Endorseets Date _d______ ,2003 _

Part G Page 39 of 68 FORM NIS-2 18-03-21 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl I. Owners AlliantlEne=MvS Ues) Date 05/1103 Name P.O. Box35,CedarRapidsIA 52406 Sheet 1 of 2 Address

2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 MWO 1125194 Address Repair Organization to P. O. No., Job No., etc.
3. WorkPerfomedbyNuclear Management Co. LLC Type Code Symbol Stamp None Name AuthorizationNo. None 3277 DAEC Road, Palo, IA 52324 Epiration Date None
4. Identification of System: Feedwater
5. (a) Applicable Construction Code ANSI B31.7 19 69 Edition N/A Addenda N/A Code Case.

(b) Applicable Edition of Section XUtilized for Repairs or Replacements 1992-A

6. Identification of Comnonents Remared or Reolaced and Reolacement Comnonents ASME Name *t Name of Manufacturer YearsBult Repaird Code Component Manufacturer Serb No. National Other Idenfification Replaced, or Stamped

. ~

.. Board No. Replacement (YES or

.____ ________ WerkOrder/Equlp

_ ID NO)

V14004 qrtr NA NIA N/A MWO 1125194 1 DIA-2-H-19 N/A Repaied No anla fpport e Gusset plate for Tuscaloosa Steel Heat# A7X3024 N/A MWO 1125194 / DLA-2-H-19 1998 Replaced No Bas Plat fo Tuoosa Sted HWa # A7X3024 M#A MWO t1l25194 1DLA-2-H-19 1998 Rped No I It __

supp.a_

7. Description of Work: Removed and reinstalled spring can support to allow installation ofequipment

] [

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure m

OtherW- Pressure N/A Psi Test Temp N/A eF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of shects is recorded at the top of this form.

(12/82) This Form (E00030) maybe obtained from the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part G Page 40 of 68 FORM NIS-2 18-03-21 FORM NIS-2 (Back)

9. Remarks: In order to replace a dwel cooler. sg can support DLA-2-H-19 was removed and re-installed During removal the base plate and 2usset plate were damagd and were replaced on restalation. After installationa vT-3(P03043 was performed onthe a ly.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replcement (repair or replacement) conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp None Certificate of Authorization No. None ExpirationDate _ N/A Signed G LE q i poEqumntMontoring Date M I g 2003 Ifr- -rftc, VA

-W WJJLIII IJLICC a L n;%:-&u, Tita ILU; (

VI 9

CERTIICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Harford, Conn. have inspected the components described in this Owncr's Report duringtheperiod Y0-o3-0? to 5 p 3 , andstate thattothebestof my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASM Code, Section XL By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his employer shall be liable m any manner for any personal injury or property damage or a loss of any kind ansing from or connected with this inspection.

Commissions N ) St , E 6e Inspector's Signature National Board, State, Povince, and Endorseznents Date 5-61-o 3 ,2003

Part G Page 41 of 68 FORM NIS-2 18-03-22 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Reqird by the Provisions of the ASME Code Section M

1. Owners Ailiant BnerM (lB tes Date 05/1103 Nam P.O. Box 351, Cedar Ripids, 1A 52406 Sheet 1 of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 CWO A62689 Address Repair Organization to P. O. No., Job No., etc.
3. WorkPerformedby NuclearManaaemenlCo. LLC Type Code Symbol Stamp None Name AuthrizationNo. None 3277 DAEC Road, Palo, IA 52324 Exiration Date Noe
4. Identification of System: Main Steam
5. (a) Applicable Constuction Code ANSI B31.1 19 69 Edition NIA Addenda N/A Code Case.

(b) Applicable Edition of Section XIUtilized for Repais or Replacements 199292

a. toenuncanon of Repaired or g aced and ku lacement LComponents Name*f Name of Manufacturer YMr t epadr Code Component Manuactrer Sera No. National Other Identfication Replaced, or Stamped Board No. Replacement (YES or Work OrderIEquip ID NO) 1j Elbow N/A NA N/A CWO A62689/DBAO01 MA Repaied No Upstaem of CV4412 (MSV)
7. Description of Work: Removed surface defects caused by nearby constuction.
8. Tests Conducted: Hydrostatic [] Pneumatic M Nominal Operating Pressure m OffherW Pressure N/A Psi Test Temp N/A °F NOTE: Supplemental sheets in form oflists, sketches, or drawings maybe used, provided (1) size is 81/2 in. x 11 in, (2) information in items 1Irough 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, NY 10017.

Part G, Page 42 of 68 FORM NIS-2 1803-22 FORM NIS-2 (Back)

9. Rernarks: Durin renlacement of he drvwell cooler the elbowiusteam ofCV4412 (Main Steam Isolation Valve) was inadverte gouged. These surface defects were mechanically removed and a successful surface exam was performed on the area. he elbow wall dimensions were sti above the nominal e tic s.

CERTIFICATE OF COMPLIANCE.

We certifr that the statements mae in the report are correct and this Reay -

(repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Auth ion No. None ThExipration Date NIA Signed :k GL Equipment Monitoring Date Owner orOwner's Designee, Title 2003 CERTIFICATE OF INSERVICE INSPECION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB Cr of Hartford, Conn. have inspected the components described in this Owner's Report duringthe period (4- 7-o to _ 5___7 , and state thatto thebestof my knowledge and belief, the Ownir has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions Nvg )d3aq/4,vz- /f9-Zz 9 InsPector's Signature National Board, State, Province, and Endorsements

> -C - 0 2 ,2003

Part G Page 43 of 68 FORM NIS-2 18-03-23 FORM NIS-2 OWNE'S REPORT FOR REPAIRS OR REPLACEMENIS As Required by the Provisions of the ASME Code Section Xl

1. Ownes Aant Ener S Uiles) Date 05/1/03 Name P. 0. Box 351, Cedar Rapids, IA 52406 Sheet 1 of 2 Address
2. plant Duane Arnold Enery Center Unit 1 Name 3277 DAEC Rbad, Palo, IA 52324 CWOA60684 Address Repair Organization to P. O. No., Job No., etc.
3. Wok Performed by Nuclear Manazement Co. LLC Type Code Symbol Stamp None Name Authorization No. None 3277 DAEC Road, Palo, IA 52324 Expiration Date None
4. Identification of System: Main Steam
5. (a) Applicable Construction Code ANSIB31.1 19 69 Edition N/A Addenda N/A Code Case.

(b) Applicable Edition ofSection XI Utilized for Repairs or Replacements 1992-2Z

6. Idenncan o ' Repaimp redor Kgoiaced and placement Lymponents ASM Name of Name *f Manufacturer Year Dfflt Repa1red Code Component Manufacturer Serial No. National Other Identification Replaced, or Stamped Board No. . Replacement (YES or WorkOrder/Equlp ID NO)

Rechuaon Ena Steel HT#592WNE N/A CWOA606841SUS64Dl 1994 Replaced No DccoFage 5 ~~ ~ I--- --

7. Description of Work: Replaced flange on Recirc System Piping.
8. Tests Conducted Hydrostatic ] Pneumatic E Nominal Operating Pressure 1-:i Other D- Pressure 1020 Psi Test Temp 210 °F NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8112 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St, New York, NY 10017.

Part G Page 44 of 68

- FORM N1S-2 S-03-23 FORM NIS-2 (Back)

9. Remarks: DAEC coats vessel internals withnobel metals to reduce corosion. Replaced flange on reciculation line. and sent rplaced flange to vendor to verify tbis coating. Replaced flange will be destroyed during vendor tests.

Copleted VT-2 after instalation of new flange (ref I0300fl.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement (repair or replacement) conforms to the rules of the ASMB Code, Section XL Type Code Symbol Stamp None Cerificate of Authoization No. None Expiration Date NIA Signed 12_ A GLEt

' ZZ;r otvwer's Designee Tile Reliability Date m q

, 2003 CERTIFICATE OF INSERVICE INSPECTION r.

1, the undersigned, holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components described in this Owner's Report during the period 3- V- o3 to __- ___ ___ ,and mi-_state that to the best of my knowledge and belief; the Owner has perfomed examinations and taken corrective measures described in this Owner's Report in accordance with the rqirements of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any waranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions Co m39misio -n , 1 9 Inspector's Signature National Board, State, Province, and Endorsements Date _S4-dt ,2003

Part G Page 45 of 68 FORM NIS-2 18-03-24 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACMENTS As Required by the Provisions ofthe ASME Code Section XI

1. Ownes Aiant Energy (S Utes) Date 05/2/03 Name P.O. Box 351, Cedar Rapids, IA 52406 Sheet 1 of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 MWO 1121803 Address Repair Oganization to P. O. No., Job No, etc.
3. Work Performed by Nuclear Management Co. LLC Type Code Symbol Stamp None Name AuthorizionNo. None 3277 DAEC Road, Palo, IA 52324 Expiration Date None
4. Idntification of System caontinment
5. (a) Applicable Construction Code ASME Section M 19 68 Edition S68 Addenda N/A Code Case.

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992-A9 r

6. iencaton or ep Red or i aced and RPlacE LOMponents_

Name of Nameof Manufacturer Year But Repared, Code Component Manuscturer Sal No. National Other Idenlficafion Replace, r Stmped Board No. Replacement (ES or WorkOrder/EqulpED _ NO) eJutaled lffng D e Steel HT#822K42160 N/A MWO 1121803/ SUSS9.OD WA Repaid NO Lugs (welded) i Replacement

7. Description of Wor ntalled two liffing lugs on DrywelL
8. Tests Conducted:- Hydrostatic [ Pneumatic El Nominal Operating Pressure Other [ Pressure N/A Psi Test Temp N/A . p NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number ofsheets is recorded at .

the top of this form (12182) This Form (E00030) maybe obtined from the Order Dept., ASME 345 E. 47th St., New York NY 10017.

  • No pressure test required per relief rapest MO-P001.

Part G, Page 46 of 68 FORM NIS-2 1-03-24 FORM NIS-2 (Back)

9. Remarks During replacement of the Prywell coolers during RFO 18. installed two fifting luas on the fywell to facilitate the ploect. Performed a VT-I P03016') of surface prior to installation of lugs. Welds for lugs received surface exam as Feaxid by construction code. No rse test was perfoed as this was considered a minor reair to the Drvwefl. and DAEC relief request MC-POO1 allows waiting until the next time a IOCFR 50 Appendix I test is performed to demonstrate leak tianess. No to WEssrie this area would retire perfommng an Tutegrated Leak Rate Test CERIMCATE OF COMIPLLANCE We certify that the statements made inthe report are correct and this ReplacementlRepair (repair or replacement) conforns to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Owiiacot3ner None Exphnation Date N/A Signed

/B/, t GL Equipment Reliabiliy Date 2003

> Owvnerfe's Designee, Title /

CERTIFICATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components described in this Owner's Report during the period I -v. to 5 , 2t, ,and state that to the best of my knowledge and belief the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions .-V6 / WI, -I--

Inspector's Signature National Board, State, Province, and Endorsements

) Ca -0o .. , 2003

Part G Page 47 of 68 FORM NIS-2 18-03-25 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions ofthe ASME Code Section XI

1. Owners Alliant Enerav (IES Utilites) Date 0516f03 Name P. 0. Box351, CedarRapids, IA 52406 Sheet I of 2 Address
2. Plant Doane Aold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 CWO A62296 Address RepairOrganization to P. O. No, Job No, etc.
3. Work Perfonned by Nuclear Ma nagement Co. LLC Type Code Symbol Stamp None Name Authorization No. None 3277 DAEC Road, Palo, IA 523: 24 Expiration Date None
4. Identification of System Reactor Core Isolation Cooling (RCIC) (CLASS 2)
5. (a) Applicable Construction Code ASME Draft P&VC 19 68 Edition N/A Addenda N/A Code Case.

(b) Applicable Edition of Section Xl Utilized for Repairs or RepLAments 1992-A92

6. Identication 0 Compo Kepared or Re laced and R lacement Componets Name f Name*r. Mnufcturer YearBullt Repaird Code Component Manufacturer Serial No. National Other Identification Replaced, or Stamped Board No. Replacunent (YES or WorkOrder/Equip ID NO)

V25-O0O1 Vave Anchor Valve 0436.12 N/A CWO A62296 /SUSS0.00 N/A Repair No

_xiSc Co _ _ _ _ _ _ _ _ _ _ _ _ __ _

7. Description of Wor Machine 0.020" from back of disc for clearance
8. Tests Conducted Hydrostatic [ Pneumatic [J Nominal Operating Pressure m otherr Pressure N/A* Psi Test Temp N/A aF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheeti is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St. New York, NY 10017.

No pressure test required per relief request MC-P001.

Part G Page 48 of 68 FORM NIS-2 1803-25 FORM NIS-2 (Back) x

9. Remarks: 0.020" was machined off the back of the disc to allow better seating of the disc. A Malmetic Particle Inspecion was crnnmletexd on the machined nrface and found accentabin CERTIFCATE OF COMPLIANCE We certifr that the statements made in the report are correct and this Repair (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificat of Authorization No. None ExpirationDate N/A Signed GL Equipment Reliability Date /724Y 2003 Owner or Owner's Designee, Tide I.

CERTIFICATE OF INSERVICE INSPECION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components descibed in this Owner's Report during the period _/- _ Y- Ad_ _ to 5_-___y X

_ , and state that to the best of my knowledge and belief, the Owner has performed examnmations and taken correctve measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or fplied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions oA/) 5 /Y96 2 Inspector's Signature National Board, State, Province, and Endorsements Date 5 -l/ ,,2003 2003 Date¶-I((

Part G, Page 49 of 68 FORM NIS-2 18-03-28 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. O0 Alliant EnerWv (lES lthlities) Date 05/14/03 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet 1 Of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1119843 Address Repair Orgaization to P.O. No., Job No, etc.
3. Work Perfonmed by Nuclear Ma naaement Co. LLC Type Code Symbol Stanp None Name Au oizationNo. None 3277 DAEC Road, Palo, IA 523;24 Expiration Date None
4. Identification of System: Main Steam Safety Relief Valve (Class 1)
5. (a) Applicable Consruction Code ASME M 19 68 Edition W68 Addenda N/A Code Case.

(b) Applicable Edition of Section X Utilized for Rpais or Replacements 1992-A2

6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer 1 Year Bullt Repaired,

~~~~~~~~~~~~

Code Component Manufacttrer SerialNo. National Other Identification Replaced, or Stamped (11angerNo.)I Board No. Replacement (YMS or

. ________ ________ I__________ _______ WorkOrder/SUS NO)

Pot Valve Taget Rock S/N 218 NA PWO 1119843183.04 1976 Replacement Yes

_ __ I _ _ _ _ _ _

4- 4* 4. 4- 4.

44 4. 4. 4. 4. 4.~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

4 4 4. 4- 4. 4. 4.

4 4 4. I- I. I- 4.

4 4 4. 4. 1. 4. 4.

t = - b

7. Descripion of Work: The Pilot Valve was epaired and documented on NS-2 (1841-02). is Pilot Valve was rotated in

_place of S/N 207.

8. Tests Conducted: Hydrostatic E Pneumatic [] Nominal Operating Pressure offier i] Pressure 1020 psi Test Temp 210 eF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 812 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is mnbered and the number ofsheets is recorded at the top of this form (12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New Yor, NY 10017.

Part G, Page 50 of 68 FORM NIS-2 18-03-28 FORM NIS-2 (Back)

9. Remars: PilotValve S/N207 wasremoved andpilotvalve SJN 218 was instaed. Priorto installation S/N218 was rnaired and documented onNIS-2 (18-01-02). A VT-2 (l03001) was completed onthe mechanical connection and found acceptable.

CERTIFICATE OF COMPLIANCE I We certify that the statements made in the report are correct and this Replacement (repair or replacement) conforms to the rules of the ASMB Code, Section XL lpe Code Symbol Stamp None Certificate of Authorization No. None Expiration Date N/A Signed <A<W 6 TL Equipment Reliability Date Mft /,A 2003 I

Ownerf6r Owner's Designee, Title q CERTIICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB Cr of Hartford, Conn. have inspected the components described in this Owner's Report duringtheperiod io- r7-6;. to - I-o . ,andstate thattothebestof my knowledge and belief the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordan with the requireents of the ASM Code, Section XL By signing this certificate neither the Iupector nor his employer makes any warranty, expressed or implied, concerning the examinations and correcfive measures descrbed in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any mnner for any personal injury or property damage or a loss of any ind arising from or connected with this inspection.

Commisions AA Q -4 >qev,- f Yf6 >-

Inspector's Signature National Board, State, Province, and Endorsements Date 5 -/Y- . not_

.Z -

Part G Page 51 of 68 FORM NIS-2 18-03-29 FORM S-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENIS As Required by the Provisions of the ASME Code Section XI

1. Owners Aiant Enerav (lES Utilities) Dat 05/14/03 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet 1 Of 2 Address
2. Plant Duane Amold Energy Center Unit 1 Name 3277 DAEC Road, Palo, LA 52324 PWO 1119844 Address Repair Organization to P. O. No., Job No etc.
3. Work Perforned by Nuclear Ma nagement Co. LI=C Type Code Symbol Stamp None Name AtonrizationNo. None 3277 DAEC Road, Palo, IA 523; 24 - -- - -Expiation Date None
4. Identification of System: Main Steam Safety Relief Valve (Class 1)
5. (a) Applicable Construction Code -AsME m 19 68 Edition W68 Addenda N/A Code Case.

(b) Applicable Edition ofSection X UWlized for Repairs or Replacements 1992A2

6. Identification of Components Repaired or Replaced and Replacement Components Nme of Nme of Manufacturer YearBuilt Repaired. Cde Component Manufacturer Serial No. National Other Identification Replaced, or Stamped (Hnger No.) Board No. Replacement (YES or WorkOrder/SUS No)

Pilot Valve Target Rock SIN 226 MA PWO 1119844 / B3.04 1976 Replacement Yes S C 1. L C I I.

-. . . =.

7. Description ofWoik The Pilot Valve was repaired and documentedoNIS-2 (1801-02). This Pilot Valve was rotated in place of SIN 201.
8. Tests Conducted: Hydrostatic [ Pneumatic [J Nominal Operating Pressure FTI Other ED Pressure 1020 psi Test Tenp 210 °F NOTE: Supplementalsheets informoflistssketchesordrawingsmaybeusecd,provided() sizeis 812 in x 11 in.,(2) information in items I trough 6 on this report is included on each sheet and (3) each sheet is numbered and the number ofsheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part G, Page 52 of 68 FORM NIS-2 18-03-29 FORM NIS-2 (Back)

9. Remarks: Pilot Valve SIN 201 was removed and pilot valve S/N 226 was installed. Prior to installation SIN 226 was repaired and documented on NIS-2 (1801-O2. A VT-2 (103001) was completed on the mechanical connection and found accptable.

CERTICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate ofA rizationNo. None Expiration Date NIA Signed 41 TL Equipnt Reliability Date V4 IC/ - 2003 I Ker or yver's Designee, Tite V r CERTiFCATE OF INSERVICE ISPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB Cr of Hartford, Con. have inspected the components described inthis Owner's Report duringtheperiod /o-'?7- o, to S /4-o2) ,andstate thattothebestof my knowledge and belief the Owner has performed examinations and taken corrective measures described inthis Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the inspector nor his employer makes any waranty, exressed or implied, concerning the xminations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal iury or propey damage or a loss of any kind arising fiom or connected with this inspection.

Commissions a Boad, S9 6 t Inspectr's Signature National Board, State, Prove and Endorsemlents Date 5 6 & - IIWA -

,-bP 6-04-.3

Part G Page 53 of 68 FORM NIS-2 18-03-30 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owners Alliant Ener (ES Uiesl Date 05/14/03 Name P. O. Box 351, Cedar Rapids, A 52406 Sheet 1 Of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1119845 Address Repair Organization to P. . No., Job No, etc.
3. Work Performed by Nuclear Managxement Co. LLC Type Code Synbol Stamp None Name AuthorizationNo. None 3277 DAEC Road, Palo, IA 523 24 - - - - - - -- -- - Expiration Date None
4. Identfication of System: Mai Steam Safety Relief Valve (Class 1)
5. (a) Applicable Construction Code ASME m 19 68 Edition W68 Addenda N/A Code Case.

(b) Applicable Edition of Section Xl Utilizcd for Repairs or Replacements 1992A92

6. Identification of paired or R laced and R lacement Components Fompn

. ^ ASME Name of Name ef Manufacrer YearBilt epaired, COde Component Manufacturer Seral NO. National Other Identification Replaced, or Stamped (anger No.) Board No. Replacement (YES or WerkOrder/SUS NO)

Pilot Vave Taret Roc} NA PWO 1119845 /83.04 1976 Replacement Yes

7. Description of Work The Pilot Valve wasirpa and docmentc d on NIS-2 (182-08).This Pilot Valve was rotated in place of q27')J2M 11170W' S. Tests Conducted Hydrostatic _Pneumatic M Nominal Operating Pressure other E- Pad 1020 psi Test Tap 210 eF -

NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each heet is unibered and the zumber ofsheets is recorded at the top ofthis form.

(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, NY 10017.

Part G, Page 54 of 68 FORMNIS-2 103-30 FORM NIS-2 (Back)

9. Remarks: Pilot Valve SIN 200 was removed and Dilot valve S/N 189 was installed. Prior to installation SIN 189 was repaired and documented on NIS-2 (18-02-08). A VT-2 003001) was ompleted on the mechanical connection and found acceotable.

CERTIFICATE OF COMUllANCE We certify that the statements made in the report are correct and tbis Replacement (repair or replacement) confms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authoaticn No. None Expiration Date NIA Signed TLEquipmentReliability Date tflr---_

H *-,*

, 2003 is

=

=

r OwnO or Owner's Designee, Title I CERTICATE OF INSERVICE INSPECTION L,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectos and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components desmed in his Owner's Report during1iheperiod l___ ____ ___to 5- J -? ,andstatethatto thebestof my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owne's Report in accordance with the requirements of the ASME Code, Section XL By signing this cerficate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Oner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inijury or property damage or a loss of any kind arising from or connected with this inspection.

________________ Commissions Pj

, J93 9q4.1 F / y9t9 -a-v Ispector's Signature National Board, State, Provnce, and Endorsements Date 5- "(o? 'iO.4-,

_ o s-v^ _ _ _

Part G Page 55 of 68 FORM NIS-2 18-03-31 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPIACEMENTS As Required by the Provisions of te ASME Code Section M

1. Owners Alliant EnerW (IFSUtWies Date 05/14/03 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet I Of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1119846 Address Repair Organization to P. O. No., Job No., etc.
3. Work Performed by Nuclear Manaeent Co. LLC . Type Code Symbol Stanmp None Name AuthorizationNo. None 3277 DAEC Road, Palo, IA 523;24 Expiration Date None
4. Identification ofSystemn Main Steam Safety Valve (Class 1)
5. (a) Applicable Construction Code ASME M 19 68 Edition S69 Addenda N/A Code Case.

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1992-A92

6. Identification of Cosponents Repaired or Replaced and Replacement Components I ~~~~~~~~~~~~

Name Of Name of Manufacturer Year Bult Repaired, Code Component Manufacturer Serial No. National Other Identification Replaced, or Stamped (Hanger No.) Board No. Replacement (YES or Work Order /SUS NO)

Stud for PSV4403 Cadinal Ht 5097296 NA FYW0 1119846 /83.04 1992 Replacement NO

. __ dIndushrial .

I I I I I I I

.~~~~~~ -

7. Description ofWoric - eplaced stud on SafetyValve PSV4403, which was damaged during dissemblY.
8. Tests Conducted.- Hydrostatic =] Pneumatic [ Nominal Operating Pressure Other [D Pressure 1020 psi Test Temp 210 NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 hrough 6 on this report is included on each sheet, and (3) each sheet is numbered and 1he number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) maybe obtained from the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part G. Page 56 of 68 FORM NIS-2 1803-3 FORM NIS-2 (Back)

9. Remarks: During removal of Main Steam Safety Valve PSV4403. stud was damaged and replaced. Successfhl VT-2 U03001) was comletod.

CERTMICATE OF COMPLLANCE We certify that the statements made in the report are correct and this Replacement (repair cr replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. None Exphnation Date N/A Signed f7?, Equpment Reliability Date .m-i 2003 Owner or Ownes Designee, Title I I PI CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components described in this Owner's Report duing the period Y- -cub to t3 5%- 1I- C ,and state that to the best of my knowledge and belief thm Owner has performed examnations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, noither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fiom or connected with this inspection.

Commissions NonV Boar,- S Inspector's Signature National Board, State, Province, and Endorsements Date 5,1if , 2003

Part G, Page 57 of 68 FORM NIS-2 18-03-32 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owners Aliant Enerv (IES Utilities) Date 05/14/03 Name P. 0. Box 351, Cedar Rapids, IA 52406 Sheet I Of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1119848 Address Repair Organization to P. O. No., Job No., etc.
3. Work Performed by Nuclear Mgnagement Co. LLC Type Code Symbol Stamp None Name AuthorizationNo. Noe 3277 DAEC Road, Palo, IA 523.24 ExpirationDate None
4. Identification of Syste Ma Steam Safety Relief Valve (Class 1)
5. (a) Applicable Construction Code ASME Im 19 68 Edition W68 Addenda N/A Code Case.

(b) Applicable Edition of Section )a Utilized for Repas or Replacements 1992A92

6. Identification of Conrn Ror l Replaced and e lacement Components Name ef Name f Manufacturer Year Built Repaired, Code Component Manufacturer Serlal No. National Other Identification Replaced, or Stamped 0(anger No.) Board No. Replacement (YES or I Target~ock VjorkOrder/SUS NO)

Pilot ValvR SIN 141 N/A r Wo 1119848/ 83.04 1976 Replacement Yes

7. Description of Work The Pilot Vahve was rpaied and docmented onNIS-2 (181-02). ThisPilot Valve was rotated in plac of SfN 176.
8. Tests Conducted Hydrostatic E Pneumatic [] Nominal Operating Pressure Other ] Pressure 1020 psi Test Temp 210 OF NOTE: Spplemental sheets informoffists, sketches, ordrawingsmaybeusedprovided(1) size is 81/2 in. x 11 in., (2) information in items 1 though 6 on this report is included on each sheet, and (3) each sheet is numbered and the nminer of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part G. Page 58 of 68 FORM NIS-2 18-03-3 FORM NIS-2 (Back)

9. Remarks: Pilot Valve S/N 176 was removed and pilot valve S/N 141 was installed. Prior to installation S/N 141 was reoaired and documented on NIS-2 (18-01-02). A VT-2 003001) was comoleted on the mechanical connection and found acceohble.

CERTMICATE OF COMPILANCE We ceri that the statements made in the report are correct and this Replcement (repair or replacement) confrms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate ofAutrization No. None Expiration Date N/A Signed TL Equipment Reliability Date

=  : = -

M4.,

I N. @

2003 I Owner

  • Owner's Designee, Tile Y I CERTIMCATE OF INSERVICE INSPECIJON 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CI of Hartfbrd, Conn. have inspected the components described in this Ownei's Report during the period 4c - r7- o A to ___ - JY-___. , and state that to te best of my knowledge and belief; the Owner has performed examinations and taken corvetive measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any aranty, expressed or implied, concerning ie exammations and corrective measures descnbed in this Owner's Report. Furtherme, neither the Inspector nor his employer shall be liable in any manner for any personal njury or property damage or a loss of any kind arising from or connected with this inspection.

_ ________________ Commissions AVC2) IV 9 -i--v Inspector's Signature National Board, State, Province, and Endorsements Date , 2003 Date 0 .2

Part GL Page 59 of 68 FORM NIS-2 18-3-33 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions ofthe ASME Code Section I

1. Owners Allhant Enea (IS ltes) Date 05/14/03 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet 1 Of 2 Address
2. Plant Duane Arnold Energy Center unit 1 Name 3277 DAEC Road, Palo, IA 52324 PWO 1 19849 Address Repair Organization to P. O. No., Job No., tc.
3. WorkPerfored byNuclear Ma iagement Co. LLC Type Code Symbol Stan None Name AuthorizationNo. None 3277 DAEC Road, Palo, IA 5232 4 Expiration Date None
4. Identification of System. Main Stea Safety Relief Valve (Class 1)
5. (a) Applicable Construction Code ASMEm 19 68 Edition W68 Addenda N/A Code Case.

(b) Applicable Edition ofSection XI Utilized for Repairs or Replacements 19922

6. Identification of CoRmon e os Re laced and lacement Components _ _ _ _

'Name of iNameof Manufacturer YearlBult RApM Code Component Manufacturer Serial No. National Other Identification Replaced, or Stamped (Hanger No.) Board No. Replacement (YES *r WorkOrder/StS NO)

P" Valve Twaget Roc SIN= NPWO MA3 It 19849/83.04 1976 Replacement Yes

7. Description of Work The Pilot Valve was repaired and documented onNIS-2 (18-02-08). This Pilot Valve was rotated in place of SIN 227.
8. Tests Canducted: Hydrostatic z Pneumatic [] Nominal Operating Pressure Other l- Pressure 1020 psi TestTemp 210 °F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 812 in. x 1 i, (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained fiom the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part Gt Page 60 of 68 FORM NIS-2 LS_03-33 FORM NIS-2 (Back)

9. Remarks: Pilot Valve SIN 227 was removed and pilot valve SIN 203 was installed. Prior to installation S/N203 was rerared and documented onNIS-2 (18-02-08). A VT-2 (10300fl was completed on the mechanical connection and found acceotble.

CERTIFICATE OF CO1 1PLLANCE We certify that the statements made in the report are correct and this Replacement (repair or replacement) conforms to he rules of the ASME Code,Section XI.

Type Code Symbol Stamp None Certificate of Authorization No. None Expiration Date N/A Signed TL equit Reliability Date Mc-n e1 2003 Owner & Owner's Designee, Title I V

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components described in this Owne's Report during the period /-;_ -*_O3 to _ - O

_- _ __ , and state hat to thebestof my knowledge and belief, the Owner has performed examinations and taken corrective measures described m this Owner's Report in accordance with th requirements of the ASME Code,Section X.

By signing this certificate neither the Inspector nor his employer m es any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report Fbrhenrore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with tis inspection.

Commissions ^'G /JUV -;d Inspectors Signature National Board, State, Province, and Endorsements Date 5-14 ,2003

Part G Page 61 of 68 FORM NIS-2 18-03-34 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPIACENMDES As Reuired by the Provisions ofthe ASME Code Section XI

1. Owners Ahlant Ener M1FMUtlies~ Date 05/14J03 Name P.O. Box351, Cedar Rapids, IA 52406 Sheet 1 Of 2 Address
2. Plant IDuane Arnold Engy Center Unit I Name 3277 DAEC Road, Palo, IA 52324 PWO 1119850 Address Repair Orgnization P. O. No, Job No, etc.
3. Work Performed by Nuclear Ma nanmenrt C. llC Type Code Symbol Stamp None Name Auorization No. None 3277 DAEC Road, Palo, IA 523:24 EpirationDate None
4. Identification ofSystem: Main Steam Safety Relief Valve (Class 1)
5. (a) Applicable Construction Code ASMEM 19 68 Edition W68 Addenda N/A Code Case.

(b) Applicable Edition of SectionXI Uized for Repairs or Replacements 1992-A2

6. Identification Of Componentr r Placed and R placement Components Name of ;Name of Manufacturer Year Boit Repaird Code Component Manufacturer Saml No. National Other Identifcation Replaced, or Stamped (Hanger No.) Board No. Replacement (YES or WorkOrderlSUS . NO)

Po Val Taget Rock SIN 202 NA PWO 11198S0/ 3.04 1976 Replacement Yes

7. Description ofWork: ThePilotValve was repard anddocumented onNIS-2 (18-01-02). This PilotValve was rotated in place of SIN 199.
8. Tests Conducted: Hydrostatic [J Pneumatic [ Nominal Operating Pressure Odker M Pressure 1020 psi Test Temp 210 NOTE: Supplemental sheets in form of lists, sktches, or drawings maybe used, provided (1) size is 81J2 in. x 11 .in,(2) information initems 1 hrogh 6 on this report is included on each sheet, and (3) each sheet is numbered and he mmber of sheets is recorded at the top of this form.

(12182) Tis Form (E00030) may be obtained from The Order Dept, ASME, 345 E. 47th St., New York NY 10017.

Part G, Page 62 of 68 FORM NIS-2 18-03-34 FORM NIS-2 (Back)

9. Remarks: Pilot Valve SIN 199 was removed and Rilot valve S/N 202 was installed. Prior to installation S/N202 was reaired and documented on NIS-2 (18-1-02). A VT-2 (103001) was completed on the mechanical connection and found acceotable.

CERTIFICATE OF COM[PLLNCE We certify that the statements made in the report are correct and this Replacement (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authorization No. None Expiration Date N/A Signed TL n Equipment Reliability Date _ _______ 2003 Owner oz~t~wr's Designee, Title j/

CERTIFICATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Conn. have inspected the components described in this Owner's Report during the period So- 7-oa to 5-I9 XA, , and state that to the best of my knowledge and belief the Owner has performed examinations and taken corrective measures described inthis Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Frthermore, neither the Inspector nor his employer shall be liable inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

commissions Commissons' vX Ar6 4v Inspector's Signature National Board, State, Province, and Endorsements Date 5-l 20

, 2003

Part G, Page 63 of 68 FORM NIS-2 18-03-35 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPIACEMENTS As Required by the Provisions of the ASME Code Section M

1. Owners Alint Enerr (ES Utiliies) Date 06t25103 Name P.O.Box35l,CedarRapids,IA 52406 Sheet I Of 2 Address
2. Plant Duane Arnold Eergy Center Unit 1 Nanme 3277 DAEC Road, Palo, IA 52324 CWO A58727 Address Repair Organization to P. O. No., Job No, etc.
3. Wok Performed by Nuclear Ma nagement Co. LLC Type Code Symbol Stamp None Name AuthorizationNo. None 3277 DAEC Road, Palo, 1A 523;24 _ ExpirationDate None
4. Identfication of System: Recirculation System Pump Seal (Class 1)
5. (a) Applicable Construction Code ASME Section M 19 68 Edition Addenda N/A Code Case.

(b) Applicable Edition of Section XIUtiled for Repairs or Replaements 1992A9

6. Icdenfication of s Rpa!d or Rcplaced and Replacement Components ASME Name of Name of h(nnucturer YearBilkt Repaired Code Component Manufacturer Seral No. National Other Identification Replaced, or Stamped (nger No.) Board No. Replacement (YES or Work Order/SUS NO)

Recirc Sea] for Byron Jackson SIN 6914-1006 N/A CWO A58727/ 64.01 1971 Replacement No 2 . _ _ ____

7. Descriptionof Wor Therplacementreciculationpu sealwasrepmedunderNS-2(1802-05).
8. Tests Conduct& Hydrostatic [ Pneumatic ] Nomial Operating Pressure Other E Pressure 1020 psi Test Tep 210 Op NOTE: Supplem a shec informoflists; sketches, ordrawings maybeused, provided.(l) sizeis 812 in x 11 in, (2) informtion in items 1 through 6 on this report is inchlued on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form (12/82) This Form (E00030) may be obtained fiom the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part G, Page 64 of 68 FORM NIS-2 1 03-35 FORM S-2 (Back)

9. Remarks: R rsal s/n 691-S-1006 replaced seal s/n 741S2741. Prior to installation seal 691-S-1006 was repaired and documented on NIS-2 (18-0205). A VT-2 (1030011 was cpleted on the assembly attached to the pm. and was found acceptable_

CERTIFCATE OF COMlUIANCE We certiy that the statements made in the report are correct and this Replacement (repi or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate ofAuhorization No. None Expiration Date N/A Sid 1i< TL Equipmnt Reliability Date 2003

/ Own7rdOwner's Desigaee, Tidle I Zkt I

I CERT{IICATE OF INSERVICE INSPECION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Irspectors and fte State or Province of Iowa and employed by HB CI of Htfrd, Conn. have nset the components described in this Owner's Report during the period /0- 6 -o, to 6- 3

_6-6 , and state thatto the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements ofthe ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this OVer's Report. Furthermore, neither the Inspector nor his employer shall be liable in ay manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 'VP,~,O~q,4,r- /44fi Inspector's Signature National Board, State, Province, and Endosments Date -e9r,200 , 2003

Part G Page 65 of 68 FORM NIS-2 18-03-36 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPIACE4ENTS As Required by the Provisions ofthe ASME Code Section XI

1. Owners - ffant Enerm (J UtLtes) Date 06/25/03 Name P.O.Box35i,CedarRapids IA 52406 Sheet I Of 2 Address
2. Plant Duane Arnold Energy Center Unit 1 Name 3277 DABC Road, Palo, IA 52324 CWO A57816-Address Repair Organzation to P. O. No., Job No, etc.
3. Work Performed by Nuclear Managenmt Co. LWL Type Code Symbol Stamp None Name Authorization No. None 3277 DAEC Road, Palo, IA 52324 Exiration Date None
4. Identification of Systemr Nuclear Boiler (Class 1)
5. (a) Applicable Constnction Code ANSI B31.7 19 69 Edition Addenda NiA Code Case.

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992-A

6. Idenfcation o xcpanw ore xacea and Replacement Lonwonents ASME Name of Name f Manufacturer YearBualt Repaired, Code Component Manufacturer Serial No. National Other Identification Replaced, or Stamped (anger No.) Board No. Replacement (YES er Work Order/SUS NO)

M119AC-11790 NA None N/A CWO A57816 / 62.00 2003 Repaid No

_____ R~~~~~~~~~~~~~~~Ieplacement

119AC-11791 N/A None N/A CWO A57916 62.00 2003 Repaid No
____ _____ ___ Replacement M119AC-11792 N/A None NA CWO A57816 / 62.00 2003 Repaid No M119AC-11793 N/A None NIA CWO AS7916 / 62.00 2003 Repaid No

.____ _____ .___ Replacent M119AC-11794 NA None NIA CWOAS7916/ 62.00 2003 Repaid No Rept-emcnt

7. Description of Worilc This work order moves the supports for DBAOO9 from existing locations to the insulation head.smmstrcture.
8. Tests Conducted- Hydrostatic E Pneumatic ] Nominal Operating Pressure El Olher ED Pressure N/A psi TestTenp N/A OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8112 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is umered and the number of sheets is recorded at the top of this form.

(12182) This Form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, NY 10017.

Part G, Page 66 of 68 FORM NIS-2 1803-36 FORM NIS-2 (Back)

9. Remarks: These five supports were moved fiom floor attachments to being mounted to the insulation head sMoerstructure.

Existing Suport were used with only modifications to the mounting. AUl welds perfoimed with Section DC uabfiedrocedmue (Pl-AT-Lh rev 8gand qualifled welders.

CERIFCATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repair/Replacement (repair or repl t) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate of Authorizatn No. None Expiration Date N/A Signed JC/ 4 -LP am TL Equipment Reliability Date C L( (0, 2003 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION the undersigned, holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB Cr of Hartford, Conn. have inspected the components described in this Owner's Report during theperiod 1/ - -o, to 7 - -c%, , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furhnmore, neither the Inspector nor his employer shall be liable in any manner for any personal inuy or property damage or a loss of any kind arising from or connected with this inspection.

_________________ Commissions A/ny rv I and /v.?

Inspector's Signature National Board, State, Province, and Endorsements Date 7- , 2003 2

Part G Page 67 of 68 FORMNIS-2 18-03-37 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPIACMENTS As Required by the Provisions offfe ASME Code Section XI

1. Owners llliant Enerz (lBS Utlities) Date 0625/03 Name P. O. Box 351, Cedar Rapids, IA 52406 Sheet 1 Of 2 Address I I
2. Plant Duane Arnold Enemrg Center Unit I Name

-"'A' 3277 DAEC Road, Palo, IA 52324 CWO A60844 .-r--`

Address Repair Organization to P. O. No., Job No, etc. I .

5:

3. Work Performed by Nuclear Management Co. LLC Type Code Symbol Stamp None Name AuthrizationNo. None 7 3277 DAEC Road, Palo, IA 52324 Epiration Date None . I-

.1

4. Identification of System: Main Steam Class II 1.
5. (a) Applicable Construction Code ANSIB31.1 19 67 Edition Addenda WA Code Case.

(b) Applicable Edition of Section [ Utilized for Repairs or Replacements 1992-A92

o. Iaenuncanon or ponenr or teKxaced an R acmenr Cormponenzs -

ASME Name ef Name of Manufacturer Year Buldt Repafred, Code Cemponert Manactuer Serial No. National Other Identificaion Replaced r Stamped.

(nger No.) Board No. Replacement (YES or

_____ Work OrderJSUS NO V&1VV Velan Unk_ N/A V03-I Unkiown Repavd No:

7. Description of Wori Repaired bodyo-bonnet leak on V034096
8. Tests Conducted- Hydrostatic L Pneumatic LI Nominal Operating Pressure Ib OtherD= Pressue 940 psi Test Temp 542 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) infrmation in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the mmnber of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, NY 10017.

Part G, Page 68 of 68 FORM NIS2 M=93-37 FORM NIS-2 (Back)

9. Remarks: Valve disassembled due to body-to-bonnet leak Machined bonnet to remove steam cutting Performed MT on machined surface. Sucmcssflulyperformed VT-2 (PO3O35; exam after installation, CERTIFCATE OF COMPLIANCE We cerff that the statements made in the report are correct and this Repair (repair or replacement) conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp None Certificate ofAuthorization No. None Expiration Date N/A Signed TL Equipment Reibility Date 9z 2 2003 Owner OOwne's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Iowa and employed by HSB CT of Hartford, Con, have inspected the components descnbed in this Owner's Report during the period _ _ 3_ _ q-_ _ to So-_ _ _ _____

_ , and state that to the best of my knowledge and belief, the Owner has performed examiations and taken corfective measures described in this Owne's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descrbd in this Owner's Report Friermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind aising from or connected with this inpection.

%1;4s n/Ve) Rh /y96tCommissions

-n hispector's Signature National Board, State, Province, and Endorsements Date _ __ ,2003 _

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20,2003 Part H, page 1 of I

1) Owners Interstate Power and Light Company. Central Iowa Power Cooperative Corn Beh Power Cooperative an Alliant Company Mar:io A. Humbolt, IA P.O. Box 351 Cedar Rapids, IA.52406
2) Plant: Duane Arnold Energy Center, Palo, A.52324 3) Plant Unit: #1
4) Owner Cafificate ofAuthorization (ifrequired): N/A 5) Commercial Service Date: 02/lt7S
6) National Board Number ofUnit NA Gros Generatg Capacity: 614 MWE ABSTRACT OF CONDMONS NOTED AND CORRECTVIE MEASURES TAKEN:

The corrective measures are addressed in this report and were performed in accordance with the American Society of Mechanical Enginees Boiler and Pressure Vessel Code, Section XL 1992 with the 1992 Addenda (Ref. Relief Request NDE-RO15 Rev. 1), and the Duane Arnold Energy Center Updated Final Safety Analysis Report The corrective measures performed as Repairs or Replacements are listed in Part F of this report and are documented, using Form NIS-2, in accordance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section Xt, 1992, 1992 Addenda. Specific details and associated records of additional corrective measures are on file at Duane Arnold Energy Center. The corrective measures addressed were performed during the period of May 28, 2001 through April 20,2003.

THIRD TEN YEAR INTERVAL INSERVICE INSPECION REPORT May 28, 2001 through April 20, 2003 This page intentionally blank

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20, 2003 Part 1, page I of 14

1) Owners: Interstate Power and Light Company, Centual Iowa Power Cooperative Corn Belt Power Cooperative an Afliant Company Marion, LA Hunbolt, IA.

P.O. Box 351 Cedar Rapids, IA 52406

2) Plant: Duane Arnold Energy Center, Palo, LA S2324 3) Plant t ni #1
4) OwnersCatificateofAuthorization(iftequired): N/A 5) Commercial Service Date: 2/01s
6) National BordNumberof Unit N/A Gross Go werating Capacity. 614 MWE ISI FIGURES AND ISOMETRICS PLEASE NOTE: ISI Figures and Isometrics are listed in Part B and Part D of this report

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20, 2003 Part 1, page 2 of 14 This page intentionally blank

Part I, Page 3 of 14 J-OA J N433 J'-IR EL. 824' -2^

DW640 J5 D 40 K8 i, LUGS DW540 MRIN STERN ""

MSA-OW440

_ _ _ _ _ _ _ _ _ _ _ _ _ _ CSo 20", G" OW340 ISO. NO. 1.2-01 P10 ISI-n 1 RPED-B2 1.7 0 1 W240 Bi Dv240

~~~~~~~~~~~~~~~~~~I 1 RB19 I I CSTEAM TUNEL)

G

~~~~~~~~~~lD ~~~~~~~~

EL. 762'

2. 2-53 I

- NON N INTEGRAL 4* - 1 FLOW ELEMENT LINE DRAW NG RELEASE RECORD REV DATE PREPARED REVIEWED APPROVED PURPOSE I 3-6-86 l RCii ISO'S FOR 2d 10 YEAR PLRN 2 t IM*W 1. , ISO'$ TO CRO FORMIT RS PER NG-9-eTS4

_-a94 Ap r REVISED PER 151 INSPECTION WALKDOWN 1-18-96 TAI Jw GP REV. PER DRF-018 3-21-96 JAH DA GP REV. PER DURF-U0027 OREC INSERVICE INSPECTIUN RSME SECTION ISOaETRIC

Part I, Page 4 of 14 DI 14 LUGS MA I STERN " B" MSB-Cs, 20" 1.2-02 ISO. NO. 1.2-02 PlED B21.ll1 SPED 2 1.7?

J DW240 R8130 (STEAM TUNEL) i4 GUIDE LUGS 2 LUGS J38 EL 76Z' J39

- NON INTEGRAL

    • - 1 FLOW ELEI OAEC INSERVICE INSPECTION RSME SECTION XI tsonETRIC

Part I, Page 5 of 14 J4-OR NsC EL 824' LUGS MRIN STERM "C"

-, MS C -

CS, 20", 6" ISO. NO. 1. 2 -03 P&ID SI-1I14 APED B21.7 0W301 DW220 RB130 (STEAM TNEL) 77'/

ZII\ 4 GUIDE /1 J34 JS6- IA EL 763' K38 J36-OR J37 J4l

  • - NON NTEGRAL CONT. ON ' ,

2" -DBA-c

    • - 1" FLOW ELEMENT LINE ISO. NO. 2-2-55 DRAWING RELEASE RECORD REV DATE PREPARED REVIEWED APPROVED PURPOSE 3-21-96 JF D - REV. PER OURF-U0027 2 5-24e-0 DR GP _ KKM ISO' S TO CRO FORMAT S PER N-85-STSI 3 1-3-91 KKI REMOVED EXTRA UEL NUMBER

-4 4-Z-,R,5 (O W ?eD OP CHRGE IS #

5 7-22-194 -DAFED- GP I RVSED PR S WECTION WLDW I-Z---4-19 A T tI DFEC INSERVICE INSPECTION RSnE SECTION K2 ISOMETRIC

-Pif tT-Pi &K6-_ f1T4:

JS J5J3NNL j A I DW530~~~~~~N~ I E.81'O J12~~~~~~~~~~J D- W3430 F F4-40 BP-402 ~ P-00

  • ~JIS ~ ~ ~~~~~W30J IK2~~~~~~~~~~~~~J9cSI I OLA-2~/D F ~2 1 K

le BPP0060J1

  • BCHDU#K2R--3H BP-403Ps-J1J31 I* - NON INTECR 0L HE- L- R10BP-4618 e P60 7 6/4/99 D 4v -01 OP FED REIEDPR UF-01

~ IIZ~ZZL

~ REVSED PER D1-eJag 4 7D 229ISIEDO 11ISPCI14~LDW EVSD E BE3C 2 96J JOLDRO-RVIEDPE3D-HU02 RE 3/26/9 PRPHE REVEUE HPOPE REIEPEUR POSE04


~ ~ - -- --- -- - - - - - - -- -- -- -- -- - -- Part- , -Page f- -- -- -- -- --

EL, 811' J Nq < 01J2 NWiC) 2J l

DI> J3 O l $ J6 DW510 J4 j7 DW410 DW310 BP-409

, i + ~~~~~~~~~~~J W520 i - l 6/ H _ _ _ _l_ _ _- - - - - --- BP-410 BP-416 DW420 X J8 DW320 FEEDWATER " C"',"D" 0W320 FWC-; FWD- BP415\

CS . 10 ",1 6\ e i rIso. NO . 1.2-06 H-,\ \ 22 PLID I-l14 J12 BECH DLG# DLA-2-4-H i - EL, 2 t+ - / ~~~~~~~~ ~~~

JL: ~~BP-6009 i t 5 J1 Kl7J17 J25 J23 itsi 0320 _ _ 4 1 -1S JZ7 FP-414 2 P-412 F B L

\~~~~~V _ BP-413 OR i i k 29 ~~~~~~~~~~~~~~BP-420 \ 33i l -58 ll6S,9-2'4 \P \ 150' 5 10 CR0 AS PER CBP-6008i

______ _ _ _ _ _DR WN RL E LORD LS DLA- J34 ioREJ

[ 16 A J37 - < "~~~~~-OBR-7J3i 3 N 82 1NTEGRL~I IiIIRB130 (STEAM TUNN L)REISED PER i i ~~~~~~~DRRUING RELERSE RECORD ________ ___ _

REY DA^TE PREMflED REVIEUED_ PPROVED PURPOSE i ~3-ll-8E 3ML SnL Rc" ISO'S FOR 2nd 10 YEAR PLANi i Z 90 GP KKi Iso, T co FoitnRT RS PER NG-60-079s 3 11-10-92 [AW . ,REViI SED PER DOC-20Y41i 47-22-94 DA BJB GP REVISED PER ISI INSPECTION WALKDOWN 5 3/26/98 DA TAK GP REVISED PER DURF-U_046 R _ REVISED PER URF-U0111

_--_-_--_ -_--_-_ -- _- - - - _ -- ____---__----------------C > C~SIl_5 b sn_ t a J _ _

Part I, Page 8 of 14

'JL' J3 f

3~~~~~~~~~~~~~~~~J K17 t~ ~ ~ ~~M 4~.

d- J22 /

ji CORE SPRAY ""

_ -J24- I N SS CS, 8" I Li ne21? 7 226 ISO. NO. 1.2-07

\ - ONJ2 PSID IST-Ml

\,</ -ix ~~~~BECH-OLS 1-H WC~~~s mse SO. NO.

NON NTEGRRL 2._4 QMEC ISERVICE ISPECTION RME SECTION XI £SOH1ETtIC

I P P F- ~~~~~~~~*

(U cE z-7-J I . E(-U 1 D

0 C-D (f)

(f)

Lii 0*-

/

  • - NON INTEGRRL DRHUING RELEASE RECORD REV DATE PREPARED REVIEWED APPROVED PURPOSE 3 I J allL RCn 6 ISO' S F OR En10 YER PL-N p 8-12-86 fl- b5SO'S To CD FORnAT As PER NG-89-87q 742 _44___3 _ _ _ G REVISED PER ISINSPECTION WALKDOWN I I I I I

-i m

_i~i  : I nRFC TINFRVlCF rTRPFCt tnN RF SFCT1 N XI rsnETRIC

Part I, Page 10 of 14 CDu t-OSm\

ST-ZIt Os I a')

ir- I

,-d 0 I _.

/  ?.I. u-R - - C I Q!z- \- m' 9i IFI 4* -J eN I IJ el,~~~~~U I-Ce I ol c It- En leY (U CO3 2

ID a m I '?

zn

L Lii LO U-)

(L I 'Cu m :r In~~a 0L a:

D I

z -J a:

0 0 5- cu 2:

CUj 0)~ ~ ~ ~ ~ ~ ~ 0C a: LU

-J C-, cn I

(-I c:

II U, u IN, Cy_ '- v, 'I II cI r

o 1-1 I-

- C wL~~L U) - lowcc 0)

} ucr la U7

-~~~~- _o

-, 1 atn -j EL (0 Cc

- t _ au co CD I-I I Z

l 9"

.0),

CD C 4n

-h NJ m J 0 4 I ID n .

Cbg DRRIUING RELERSE RECORD REV DRTE I PREPARED REVIEWED APPROVED PURPOSE I -1S-e6 SlL SlL Rci [SO'S FOR 2 16 YEAIR PON 2 S-2-se _ KKM IS5 S TO CD FORQMr hS PER NC-65-0794 4

W -Zq 7-22-94 ZZ1- DA - J99 ADDED FLRINGE

-FE _ _ GP REVISED PER _51 INSPECTI WA (DN 5 7-6-95 DA __ _ --

_p REVISE PER DURW-0013 6 2-l196 mm ~ ~ ~TAK~ ~ ~ ~ JW_-REV. ~ - W _

PER F-001 DREC IN5ERVICE ISPECTION SnE SECTION XI ISOMETRIC

Part I, Page 11 of 14 to cI C--

DC C3 I I

.0 m0

-I I

C-9 LL L.

UD LiI Lhi V) cv Of

@ I ccnr

~ t n

I U CD CZ LLI 0*

Lu 0 0 GE Cu 57- LL

~ r (U

I

-j CD

  • --) hi V* 0*

U cv~ 0 G) Lo Z C hi tW-4

-J Ic 4 z CDm I

cr 3i"

_U O wo I C Im -J r 0*

cc:

I-_ c

% C U)

U, Law

  • La-X wk w w LS t: II N 0

7 r_ 0*- cnD-

______ _______ DRRWING RELERSE RECORD REV DATE PREPAREB REVIEWED RPPROVED PURPOSE 1 3-2 86 _ L _ .L RCn ISO' S FOR 2nd 10 YERR PLAN 2 q-Zn-qo f ISU'S TO CAD FORmlr RS PER C-fl-UT94 3

4 m

7-22-9?4

_1-18-96 m

-DA TAK S

j JA 3

/ 3 BSP

__REV REVISED PER ISI ISPECTION WLKDOWN PER BUF-DOLO note -- eceteYVr t.eo Tn. - e& er .n.-. rrnnr-wr

r- - - - - - - - ---- - - - - - ------- --- --- --- - - - - - - - - - - - - - - - - -_-- - - - - --- - - - - - - - _- _-_-

Part I, Page 12 of 14 I W CL l t ttr s=LE sYuEb z

l ~~~~~~I I 0

oL I LI /cofZ

  • rOC tn3 ° '/,

m 1 ~ ccinI ~~-CU 0~~~~~~~~~~~~U a!

'l z 0, t I l ON - z I0~

Er) 0~~ C3 Q ix u .i J: t w cu~~~~~~~~~~~~~~~~~~~~C 12 3 CL tr~u 3 0~~~~

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~L n  ; s~z

~

1CD~0

_ C CY)ts) cc~

CI- I cr~~~~~~~~RGIRRIEISFCINRfESCINX SfERq REV ORTPPEPRRD REV'UE RPROE PUPS 1L RCI rso's FOR 2 nd 10 YEAR PLAN Z 1'7att~~~~~~~~* lt

-- ISO' S TO CRD FORMRT RS PER HC-89-0799 3 7-22-94 DA JAH / BJB GP REVISED PER ISI INSPECTION WALKDOWN 4 1018/96- TAK JW GP REV. PER DURF-0018; 5 1/13/00 JW en TAK GP REV.PER DURF-0136 O S E ESC X T


I

Part I, Page 13 of 14 C~u Io~~~~~0: I C,~~~C L)

Ii..~ ~ I

- ~~~D LI c mm~~~~~~~~:

ccn I1 D(U~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~L co~~~~~~~~~~~~~~~~.  %

~~~~~

cri ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Id

  • ~L LI L)~~~~~~~~~~~~~~~U 0~~~-

a_ =r r Z) cu ~ ' *-A'o CREC INSERVICE INSPECTION RSME SECTION X ISOMlETRIC

Part I, Page 14 of 14 Jcu )cK1 VI LI L U u I 01 U.

w (Uu U U.OI * (

CD U* L IL cr~~~~~~~~c u c LA.~~~~~~~I 0 z x~~~~~~~~~~~

U U)... fl~~~~

-~~~~~~~~~ 15~~ *L in xI 0~~~~~~~~~~~~Q L a- (s)~ ~~-

z Lk

________ ORRIIIN LELRU REOR 10- 2 C17 CP Pt! k--4~~~

R0OA F RSTE TORRLN 1703 _ _ _ _ _ _ _ _ _ _ _ l EV. P R o W - 1 OAEC NSEtVICE INSI'ECIIOt hStlE ECTION I ISOIETR!C

TIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May28, 2001 through April 20,2003 Part J page of 4

1) Owners: Interstt Power and Li Company, t Cental loa Power Cooperative Corn Belt Power Cooperative an Alliant Company Marion. 1A. Humbolt, LA.

P.O. Box 351 Cedar Rapids, A. 52406

2) Plant Duane Arnold Energy Cent, Palo, IA.52324 3) PlantUnit: #1
4) Owners Certficate ofAuthorization (ifrequired): NIA 5) Cmmercia Service Date- o2wmins
6) National Board Number ofUnit NIA Gross Generatig Capacity: 614 MWE STATUS OF WORK FOR THIRD TEN YEAR INTERVAL (Those percentages shown are actual, where the percentages exceed the allowable only the maxinmum (50% for

-period one and at least 16% for period two) will be taken credit for).

CLASS 1 ITMNO. TOTAL F PERIOD I PERIOD 2 PERIOD 3 REMARKS BL.11 4 0%/ 0%/0 0%/0 BI.12 8 0%1/ 0%/0 0%/0 BI.21 2 25% 50%16 0%1/

BI .22 15 0%/e - 0%/0 0%/

B1.30 1 50% 50% 0%/ See Note 7 BI.40 1 33% 67%/ 0%/

BI1.5l I 0%1/ 0%/0 0%/

B3.90 33 48% 73% 0%/ See Note 1,8 B3.100 33 48% 73% 0%/ See Note 1,8 B4.l1 2 0%e0 0%/0 0%/ See Note 2 B4.12 89 0oe% 0%/. 0%/ See Note 2 B4.13 30 0%8 0%/0 0%/ See Note 2 B5.10 14 50% 71% 0%/ See Note 8 and I B5.20 8 38% 63% 0%/ See Note 11 B5.130 8 38% 63% 0%/ SeeNote 11 B5.140 2 0%/ 50016 0%/ See Note 11 B6.10 60 33% 67% 0%1/

B6.20 56 29% 64% 0%/

B6.30 4 100%/. 100% 0%/

B6.40 60 33% 670% 0%/

B6.50 60 33% 67%/ 0%/

B6.180 2 0%/0 0%/0 0%D/ See Note 3 B6.190 2 (r/o 0%/0 0%1/ See Note 3 B6.200 2 0%/ 0%/0 0%/ See Note 3 B7.10 3 33% 67% 0%/

B7.50 5 20% 20% 0%/ See Note 3 B7.60 2 0%D/ 0% 0%/ See Note 3 B7.70 47 4% 6% 0%/ See Note 3 B7.80 89 15% 15% 0%/ See Note 3 B9.11 94 22% 33% 0%/ See Note 11 B9.12 0 0%/ 0% See Note 6 and 11 B9.21 9 22% 22% 0%/ See Note 11 B9.31 6 17% 33% 0%/ See Note 11 B9.32 1 0%/0 0%/0 0% See Note 11 B9.40 23 22% 40%/o 0% See Note 11 B 10. 10 1 0% 0%/0 0% See Note 4 B 10.20 3 33% 67% 0% See Note 4

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May28, 2001 through April 20,2003 Part , page 2 of 4

1) Ownem- Interstate Power and izt Company, Centrl Iowa Power Coopeative Corn Bch Power Coopeative an Alliant Company Marion, LA_ Hunbolt, IA.

P.O. Box 351 Cedar Rapids, IA 52406

2) Plant: Duane knold Energy Center, Po LA. 52324 3) Plant tUnit: 1
4) Owners Certificate ofAutorization (if required: MA 5) Comm rciia Service Date: 0210nm5
6) NationaBoardNumnberofUnit: NA Gross Get ierating Capacity. 614 MWE STATUS OF WORK FOR THIRD TEN YEAR INTERVAL CLASS s MM NO. TOTAL# PERIOD I PERIOD 2 PERIOD 3 REMARKS B1O30 1 0/o 0°h 0% SeeNote4 B12.20 2 0% 0% 0%/

B12,50 45 6% 9% 0/e See Note 3 B13.10 35 37% 63% OOA B13.20 11 36% 36% 0D B13.30 27 4% 4% 0%

B13.40 5 20%/e 20% 0%/D B14.10 3 0D 0% 0°h B15.10 I N/A N/A N/A Onceperrefueling outage B15.11 I N/A N/A N/A Onceperinterval CLASS 1 AND CLASS 2 Risk Informed ITEM NO. TOTAL # PERIOD I PERIOD 2 PERIOD 3 REMARKS R-l 70 0%/ 33% 0% SeeNote 11 CLASS 2 ITEM NO. TOTAL # PERIOD I PERIOD 2 PERIOD 3 REMARKS C1.10 2 500/h 50% 0Y C1.20 1 0% 100/o 0%

C2.21 2 0% 50%10 0%

C2.22 2 0°/ 50% 0°h C3.10 I 0%/O 0%/. 0% See Note 4 C3.20 7 29% 57% 0% See Note 4 C5.51 69 17% 36% 0% See Notc C5.81 I 100% 100°/ 0°h See Note 11 C7.10 5 N/A N/A N/A Once per period C7.20 5 N/A N/A N/A Once per interval

TIIRD TEN YEAR INTERVAL INSERVICE INSPECION REPORT May 28, 2001 hough Aprl 20,2003 Part J page 3 of 4 I) Owne interstate Power end Light Company, Central Iowa Power CooperAtive Corn Belt Power Cooperative an Alliant Company Marion, IA. Huznbolt, LA_

P.O. Box 351 Cedar Rapids, I. 52406

2) Plant Dune Arnold Energy Center, Palo, 1A. 52324 3) PlantUnit l
4) Owners Certificate of Athorirxtion if requred: N/A 5) Commercial Service Datei 02101,75
6) Natioa BoardNunber of Unit N/A Gross Generating Capacity: 614 MWE STATUS OF WORK FOR THIRD TEN YEAR INTERVAL CLASS I AND 2 SUPPORTS ITEM NO. TOTAL # PERIOD I PERIOD 2 ERIOD 3 REMARKS F1.10 42 33% 64% 00x See Note S F1.20 52 27% 58% 00h/ See Note 5 F1.40 20 40% 65% (0/0 See Note 5 STATUS OF WORK FOR W) FIRST TEN YEAR INTERVAL I CLASS MC I IM NO. TOTAL PERIOD PERIOD 2 PERIOD 3 REMARKS El.ll 3 33% 67% 0/0 E1.12 31 19% 55% 0%/0 El.20 8 38% 75% 0%/0 E4.11 2 0/. 40% 0%/0 See Note 9 E5.30 4 25% 50%1o 0%/0 E8.10 14 29% 57% 0%/0 E9.20 N/A N/A NIA Sce Note 10

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20, 2003 Part J, page 4 of 4 I) Ownems Interstate Power and Light Company, Central Iowa Power Cooperative Corn Belt Power Cooperative an AlliantCompany Marion, IA. Humbolt, IA.

P.O. Box 351 Cedar Rapids, IA. 52406 2)- Plant Duane Arnold Energy Center, Pai, IA 52324 3) Plant Unit #1

4) OwnrsCeiificateofAuthortion(itrequied): N/A 5) Commercial Service Date: 02/01/s
6) National Board Number of Unit N/A Gross Geneadin Capacity. 614 MWE STATUS OF WORK FOR THIRD TEN YEAR INTERVAL NOTE 1- Item Numbers B3.90, B3.I00 There are a total of 34 nozzles, however I of the nozzles is exempt by IWB-1220(c) and not included in the percentages.

NOTE 2 - Item Numbers B4.1 1, B4.12, B4.13 These items are required to be examined during conduct of the system hydrostatic test, ES Utilities has implemented Code Case N-498-1 (TAP-P01 1)

NOTE 3 - Item Numbers B6.180, B6.190, B6.200, B7.50, B7.60, B7.70, B7.80, B12.50 These examinations are performed when the component is disassembled for other reasons. Therefore IWX-2412-1 does not apply.

NOTE 4 - Item Numbers B10.10, B10.20, B10.30, C3.10, C3.20 These item numbers are from Code Case N509 (1IAP-1007)

NOTE 5 - Item Number Fl.10, F1.20, F1.40 These item numbers are from Code Case N491 (TAP-I008)

NOTE 6 - Item Number B9.12 There are no welds counted for this item number because of the use of Code Case N-524 (NDE-RO 12)

NOTE 7 - Item Number B1.30 50°/. of the shell-to-flange weld may be performed during the first and third inspection periods as allowed by Note 4 of Table IWB-2500-1.

NOTE 8 - ItemNumbers B3.90, B3.100, BS.10 Relief Request NDE-R035 allows alternative percentages (ref. Code Case N-598). 2 of the Nozzle-to-safeend welds (RRB-F002 and RRD-F002) have been repaired by applying a weld overlay. These two welds are now covered by the requirements of BWRVIP-75.

NOTE 9 - Item Number E4.11 The DAEC has evaluated the need for augmented examination per this item number and has determined that the Torus should be examined twice per interval. Details are specified in Technical Approach and Position TAP-E002.

NOTE 10 - Item Number E9.20 There are no components identified under this item number because the DAEC has been approved to use Option B of Appendix J. The "Performance Based Containment Testing Program" contains the requirements.

NOTE 11 - Item Numbers B5.XX, B9XX, C5MXX, and R-I Risk-Informed methods are utilized as described in EPRI TR-1 12657B-A to determine scope of inspections for examination categories B-F, B-J, and C-F-2. The Risk-Informed scope has been combined into a new item number R-I for implementation in the second and third periods of the third interval.

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May28, 2001 through April 20, 2003 Part K, page 1 of I

1) Owners: est Power andLight Company, Central lowa Power Cooperative Corn Bek Power Cooperative an Alnat Company Muion, LA. Humbolt, Lk.

P.O. Box 351 Cedar Rapids, LL 52406

2) Plant Duane Arnold Energ Center, Palo, LA. 52324 3) PlantUnit #1
4) Owners Ceficate ofAuthorization (ifrequird): N/A 5) CommercialServiceDat 02/01M
6) National Board Number ofUnit: MA Gross Generating Capacity: 614 MWE RELIEF REQUESTS The following are the relief requests and code cases that were used during the period of this Sunmary ReporL RELIEF REOUESTS DESCRIPTION NDE-RD11 Use of Existing Calibration Blocks as an alternative NDE-R012 Alternative Examination of Class I and 2 piping longitudinal seam welds NDE-R014 Exemption from Appendix m calibration block notch dimensions NDE-ROlS Rev. I Use of the 1992 Addenda of ASME Section X1 to govern repairsrplacements NDE-R035 Alternative Requirements to Required Percentages of Examinations NDE-R038 Alternative Requirements to VII-4240 "Annual Training" NDE-R041 Use of the 1992 Edition of ASME Section XI for "Additional Examinations" PR-002 Alternative Testing for Class2 Pressure Retaining Containment Penetrations connected to non-safety related piping systems MC-R001 Qualification of Nondestructive Examination Personnel MC-R002 Alternative to VT-3 for Seals and Gaskets MC-R003 Alternative to Torque Test of Bolting MC-R004 Preservice Examination of Reapplied Paint or Coatings MC-RO05 Visual Examination of Painted or Coated Containment Components Prior to Removal of Paint of Coatings MC-R006 Successive exaninations of Repaired Areas CODE CASE # DESCRIPTION N.416-1 (PR-004) Alternative pressure testing requirements for welded repairs or installation or replacement items by welding, Class 1, 2, and 3.

N-491 (AP-100) Alternative rules for examination of Class 1, 2, 3 and MC component supports N-50S-1 (NDE-R033) Rotation of Serviced Snubbers and Pressure Relief Valves for the Purpose of Testing N-516-1 (NDE-R042) Underwater Welding N-546 (PR-008) Alternative requirements for Qualification of VT-2 Examination Personnel N-598 (NDE-R035) Alternative Requirements to Required Percentages of Examinations

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT May 28, 2001 through April 20,2003 This page intentionally blank

Attachment 2 to NG-03-0509 ASME Section Xi Summary Report Duane Arnold Energy Center Refueling Outage 18 (Period 3)

25 Years of Rock SoliPfo a t-W

~~~~~ENERGY. CENTER,':

- , _ 4 ~~~~~MERAtNEMQ NCIE 94ma ,

ASME Secti~~on XSumayRpr Rock Solid Perforinane ASME Section Xi Summary Report Duane Arnold Energy Center Refueling Outage 18 (Period 3)

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31,2003 through April 20,2003 DUANE ARNOLD ENERGY CENTER UNIT #1 PALO, IOWA Commercial Service Date: February 1, 1975 THIRD TEN YEAR INTERVAL INSERVICE INSPECTION

SUMMARY

REPORT March 31,2003 through April 20,2003 Dated April 20,2003 OWNER.

ALLIANT ENERGY P.O. Box 351 Cedar Rapids, Iowa 52406 Prepared by: __ _ Date: 7 'IIW?fD3 ASME Section Xl AIdmnj rS Reviewed by: ___ _ _ _ Date: _______

NDE Level m Reviewed by: * /-x: Date: _ ____

Program Engineering Staff Reviewed by: Date: W° 3

`EupAt keli;dty SoI Concurred by: _ _ _ _ _ Date: 0_3 I'7-Program Engineering Manager

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 This page intentionally blank

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 TABLE OF CONTENTS PART DESCREPION PAGE NO.

A Form NIS1 Pages 1-2 B Certificate of Inservice Inspection Pages 1-3 C Abstract Page I D Table of Component and Weld Examination Identification Records Pages 1-4 E Table of Additional and Successive Examinations Identification Records Page 1 F Abstract of ASME Section XI Repairs and Replacements Page I G Form NIS-2's Page I H Abstract of Conditions Noted and Corrective Measures Taken Page I I ISI Figures and Isometrics Pages 1-52 J Status of Work for Third Ten Year Interval Pages 1-4 K Listing of Relief Requests and Code Cases Utilized Page I

TMRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT Mardh 31, 2003 through April 20, 2003 This page intentionally blank

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part A, Page I of 2 FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules I .Owner. Interstate Power and Light Company. an Alliant Co.. P.O. Box 351.Cedar Rapids. IA 52406 *

(Name and address of Owner)

2. Plant: Duane Arnold Energv Center. 3277 DAEC Road. Palo. IA 52324 (Name and Address of Plant)
3. Plant Unit 1 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 02101175 6. National Board Number of Unit - N/A
7. Components hIspected This report includes a Table of Contents (P1), Part A (PP1-2), Part B (PP1-3), Part C (P1), Part D (PP1-4), Part E (P1),

Part F (P1), Part G (P1), Part H (P1), Part I (PP1-52), Part J (PP1 -4), and Part K (P1).

-Component or Manufacturer Manufacturer State or National Appurtenance or Installer S tal No. Province No. Board No.

Reactor Chicago Bridge :34833' N/A 3663 Pressure & Iron Vessel (V)

Refer to Part B, Pages 1-3, ofthis report for a continuation of components examined

_ _ _ I:_ I: _ I _ I _

Note: Supplenental sheets in form of ists, sketches,ordrawings maybe used provided (I) size is S.5 X 11 inches, (2) information in items I through 6 on this data report is included on each sheet, and (3) each sheet is nunbered and the number of sheets is recorded at the top of this for (12/82) This form (E00029) may be obtained fom the Order Dept, ASME, 345 E. 47th SL, New York N.Y 10010

TIIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April20, 2003 Part A, Page 2 of 2 FORM NIS-1 (back)

8. Examination Dates 3/31/03 to 4/20/03 9.1ispectionIntervalfrom 11l01/96 to 11/01/05
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval.

Refer to Part C, Part D, and Pat J.

11. Abstract of Conditions Noted Refer to Part H.
12. Abstract of Corrective Measures Recommended and Taken Refer to Part H.

We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code, Section Xl.

Date J 2003 SignedW 4 ~~~~~~~~~By 9int^l ee.-7n Al t~

Certificate of Authorization No. (if applicable) / r* Expiration Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of Iowa and employed by HSB CT ofHartford CThave inspected the components described in this Owner's Data Report during the period 30 to 04/20/03 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Data Report in accordance with the requirements of the ASME Code, Section )a.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Data Report. Furthermore, neither the Inspector, nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 7- 2003,

____________________________.____________C ommissions QV 4 i Y9 Ispector's Signature National Board, State, Province and No. o49 i/a,

  • Note- Oer owner m Ctal lowa Power Cooperative ad Com Belt Power Cooperatie

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part B, page I of 3

1) Owners: Interstate Power jmd Light Company, Central lowea Power Cooperative Con Belt Power Cooperative an Alliant Company Marion, L. Hwnbolt, IA P.O. Box 3SI Cedar Rapids, LA 52406
2) Plant: Duane Arnold Energy Center, Palo, LA 52324 3) PlantUnit: #1
4) Owners Cartificate of Authoriation (ifrequiref): NIA 5) Coenrcial Service Date: 020s/75
6) National Board Number of Unit: N/A Gross Generating Capacity: 614 MWE CERTIFICATE OF INSERVICE INSPECTION COMPONENTS EXAMINED:

Reactor Pressure Vessel:

Manufacturer Chicago Bridge and Iron Post Office Box 13308 Memphis, IN 38113 National Board Number 3663, Mfr. Serial Number 3-4833 Refer to Part A, Page 1, form NIS-1, Owners Data Report for nservice Inspections.

Piping:

Manufacturers, sizes, part numbers and locations are noted and traceable through the piping isometric and piping instrumentation drawings (P&ID). Installation contractor, fabricator, systems P&lD's and Isometric drawings are listed below.

Constructor:

Bechtel Power Co.

P.O. Box 3865 San Francisco, CA 94119 Fabricator -

Southwest Fabricating and Welding Co.

P.O. Box 9449 Houston, IX 77011

TEIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 trough April 20, 2003 Part B. page 2 of 3

1) Ownra. Interstate Power and Liht Company, Ceral Iowa PowCooperative Corn Belt Power Cooperative an Alliant Company Marion, Lt Humboh L P.O. Box 351 Cedar Rapids, IA.52406
2) Plant Duane Arnold Energy Center, Pal% IA.52324 3) Plant Unit: #1
4) Owners Certificate of Authrization (if required): N/A 5) Comercial Service Date 02/0117s
6) NationalBoardNumberofUnit N/A Gross Generating Capcity: 614 MWE CERTIFICATE OF INSERVICE INSPECTION COMPONENTS EXAM[NED:

CLASS Component Iso No Vessel Stud and Ugament 1.1-05 Main Steam 1.2-01/-2 Feedwater 12-05 Core Spray 1.2-08 High Pressure Coolant Injection 1.2-09 Reactor Water Cleanup 1.2-1 IA CRD Return 1.2-12A Residual Heat Removal 1.2-15 Recirculation System 1.2-19AI-19B/-20/-21B Head Vent 1.2-24 Standby liquid Control 1.2-27 Recirculation Pump 13-03 ivVI Component Iso No Top Head Assembly VS-1-6 Core Spray Bracket VS-1-26 Feedwater VS-1-27 Guide Rod Bracket VS-1-28 Steam Dryer Support Brackets VS-1-29 Steam Dryer Hold-Down Brackets VS-1-30 Surveilance Specimen Bracket VS-1-31

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 ffirough April 20, 2003 Part B, page 3 of 3

1) Owners Interstate Power and Ught Corpany, Central Iwa Power Cooperaive Corn Belt Power Cooperative an Alliant Company Marion, IA. Humbolt, LtA P.O. Box 351 Cedar Rapids, LA 52406
2) Plant: Duane Arnold EnergyCenter, Palo, IA.52324 3) Plant Unit #1
4) Owners Certificate ofAuthorization (if rAired): N/A 5) Comm rcial Service Date: 210inS
6) National Board Number of Unit: MA Gross Goieratg Capacity 614 MWE CERTIFICATE OF INSERVICE INSPECTION COMPONENTS EXAMINED:

Component Iso No Jet Pump Riser Support Pad VS-1-34 Shroud Support Assembly VS-2-10 Ledge Segment Plates VS-2-11 Core Plate VS-3-2 Per. Fuel Support VS-3-9 Top Guide VS4-Sample Holder VS-10-2 CRD Guide Tube VS-12-4 CLASS 2 Component Iso No RHR Heat Exchanger 2.1-01 Residual Heat Removal 2.2-32-33/-361-37A/-391-411-43 High Pressure Coolant Injection 2.2-441-45/-46 Core Spray 2.2-49/-52B Main Steam 2.2-53/-55/-57 Scram Discharge 2.2-60/-61 Reactor Core Isolation Cooling 2.2-62

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 This page intentionally blank

TIIIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20,2003 Part C, page 1 of 1

1) Owners: Interstate Power and Light Company, Cntmal Iowa Power Cooperative Corn Belt Power Cooperative an Ailiant Company Marion, UL Hurmbo, IA.

P.O. Box 351 Cedar Rapids, ILA52406

2) Plant: Duane Arnold Energy Ctr, Palo, ItA52324 3) PlantUnit #1
4) Owners Ctficate ofAuthor n (ifrquired): NA 5) Commercial Service Date: 02/01175
6) National Board Number of Unit NA Gross Generating Capacity 614 MWE CERTIFICATE OF INSERVICE INSPECJION ABSTRACT:

The Inservice Inspection addressed in this report was performed in accordance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section Xl 1989 Edition, No Addenda, and the Duane Arnold Energy Center Updated Final Safety Analysis Report The inspections were performed utilizing Non-Destructive Examination Techniques (i.e., UT, PT, MT, etc.). The examinations were conducted during the period of March 31, 2003 through April 20, 2003. The specific details and associated records of the examinations are on file at Interstate Power and Light Company.

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 This page intentionally blank

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part D, page 1 of 4

1) Owners: Interstate Power and Ught Company, Central lowa Power Cooperative Corn Belt Power Cooperative an Alliant Company Marion, LA Humbok, IA P.O. Box 351 Cedar Rapids, IA 52406
2) Phnt: Duane Arnold Energy Center, Palo, IA. 52324 3) Plant Unit #1
4) Owners Certificate ofAuiorization (if required): N/A 5) Commercial Service Date: 02/0l75
6) National Board Number of Unit: N/A Gross Generating Capacity- 614 MWE COMPONENT AND WELD EXAMINATION IDENTIICATION RECORDS CLASS I ISI ASME Xl Component Description Report Examination ISI Iso Category Results RPV Stud/Nut CLSR HD-LGMNTS 103002 UT 1.1-05 B-G-1 Accepted and Ligaments (41-60)

CLSR HD-NUTS 103002 VT-I 1.1-05 B-G-1 Accepted (41-60)

CLSR ED-STUDS 103002 UT 1.1-05 B-G-1 Accepted (41-60)

CLSR HD-WSHRS I03002 VT-I 1.1-05 BO-1 Accepted (41-60)

Main Steam CV4413-BOLTING I03117 VT-I 1.2-01 B-G-2 Accepted CV4413 I03116 VT-3 1.2-01 B-M-2 Accepted MSA-KO11B I03003 VT-3 1.2-01 F-A Accepted MSB-K019 103004 VT-3 1.2-02 F-A Accepted Feedwater FWB-KO20A 103010 VT-3 1.2-05 F-A Accepted Core Spray CSB-KO10 I03018 VT-3 1.2-08 F-A Accepted High Pressure PSA-KO18 I03020 VT-3 1.2-09 F-A Accepted Coolant Injection Reactor Water CUA-KO13AA I03021 VT-3 1.2-11A F-A Accepted Cleanup CUA-KO14A 103022 VT-3 1.2-1 IA F-A Accepted CRD Return CRA-K026 103032 VT-3 1.2-12A F-A Accepted RHR RHC-KO08A 103033 VT-3 1.2-15 F-A Accepted RHC-K013 103034 VT-3 1.2-15 F-A Accepted By Evaluation CE0670 &

CE00707)

Recirculation RCA-K009 103039 PT 1.2-19A B-K Accepted System RCA-K009 103039 VT-3 1.2-19A F-A Accepted RDA-K017 I03040 VT-3 1.2-19B F-A Accepted RMA-K009 I03042 VT-3 1.2-20 F-A Accepted RDB-K022 I03055 VT-3 1.2-21B F-A Accepted Head Vent HVA-FLG-BOLIlNG I03056 VT-I 1.2-24 B-G2 Accepted SBLC LCA-KO07A 103061 VT-3 1.2-27 F-A Accepted Recirculation RPB-K001 103062 VT-3 13-03 F-A Accepted Pump RPB-K001 (LUGS) 103062 PT 13-03 B-K Accepted RPB-K006 103063 VT-3 13-03 F-A Accepted

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part D Page 2 of 4

1) Owners: Interat Power and Ligh Company, Central lo" Power Cooperative corn Belt Power Cooperative an AliantCompany Marion. A. Hurnbolt, Lk P.O. Box 351 Cedar Rapids, [A. 52406
2) Plant Duane Arnold Enery Cente, Palo IA.52324 3) Plant IJnit #1
4) Owners Certificate of Audorization (ifrequired: N/A 5) Cmar=ercial Service Date: 02J0is
6) National Board Number of Unit WA Gross GaeratingSCapacity 614 MWE COMPONENT AND WELD EXAMINATION DENTIFICATION RECORDS CLASS I IS1 ASME XI Component Description Report Examination ISI Iso Category Results Reactor Vessel VESSEL HEAD 103064 VT-3 VS-1-6 B-N-I Accepted Internals CSB WELDS-150 103064 VT-3 VS-1-26 B-N-2 Accepted FWB WELDS-SE4 103064 VT-3 VS-1-27 B-N-2 Accepted FWB WELDS-SWl35T 103064 VT-3 VS-1-27 B-N-2 Accepted GRB WELDS-0 AZ 103064 VT-3 VS-1-28 B-N-2 Accepted GUIDE ROD BRT(0) I03064 VT-3 VS-1-28 B-N-I Accepted DSB-135T 103064 VT-3 VS-1-29 B-N-2 Accepted DSB-4r 103064 VT-3 VS-1-29 B-N-2 Accepted DIB-149 103064 VT-3 VS-1-30 B-N-2 Accepted DHB-31" 103064 VT-3 VS-1-30 B-N-2 Accepted SH WELDS-1080-LW 103064 VT-I VS-1-31 B-N-2 Accepted SH WELDS-1080-UP 103064 VT-3 VS-1-31 B-N-2 Accepted SH WELDS-36 -LW 103064 VT-I VS-1-31 B-N-2 Accepted SH WELDS-36*-UP 103064 VT-3 VS-1-31 B-N-2 Accepted JPR-SUPP PAD-1 080 103064 VT-I VS-1-34 B-N-2 Accepted JPR-SUPP PAD-216 103064 VT-I VS-1-34 B-N-2 Accepted SHROUD LEDGE 103064 VT-3 VS-2-10 B-N-2 Accepted (180-360)

SHROUD LEDGE I03064 VT-3 VS-2-11 B-N-I Accepted (180-360)

CORE PLATE I03064 VT-3 VS-3-2 B-N-I Accepted CSS-FUEL SUPP I03064 VT-3 VS-3-9 B-N-2 Accepted CAST CSS-TOP GUIDE I03064 VT-3 VS-4-1 B-N-2 Accepted SAMPLE HLDR-1080 103064 VT-3 VS-10-2 B-N-I Accepted CSS-CR GUIDE TUBE 103064 VT-3 VS-12-4 B-N-2 Accepted CLASS I PRESSURE TESTS ISI ASME Xa Component Description Report Examination ISI Iso Category Results Class I System Leakage Test 103001 VT-2 ISINO-P B-P Accepted

TIIIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part D Page 3 of 4

1) Owners: Interstate Power and Light Company, Central Iowa Power Cooperative Corn Belt Power Cooperative an Alliant Company Marion, LA. Humbolt, IA.

P.O. Box 351 Cedar Rapids, LA 52406

2) Plan Duane Arnold Energy Cent, Palo, L 52324 3) Plant unit #1
4) Owners Certificate of Authorization (ifred): N/A 5) Comi arcia Service Date o2nimf
6) National Board Number of Unit: NA Gross Geriernting pQcity. 614 MWE COMPONENT AND WELD EXAMINATION IDENTIFICATION RECORDS r CLASS 2 ISI ASME Xl Component Description Report Examination ISI Iso Category Results Residual Heat HEA-CA-I 103065 UT 2.1-01 C-A Accepted Removal Heat Exchanger HEA-CB-2 103066 MT 2.1-01 C-B Accepted UT Accepted HEA-CB-2 (Inner Rad) 103066 UT !1-01 C-B Accepted HEA-CC-7 I03067 MT 2.1-01 C-C Accepted VT-3 2.1-01 F-A Accepted HEA-CC-8 (04) I03068 VT-3 2.1-01 F-A Accepted Residual Heat RHA-CE009 103069 MT 2.2-32 C-C Accepted Removal VT-3 F-A Accepted RHA-CE027 103070 VT-3 2.2-32 F-A Accepted RHB-CE050 103071 VT-3 2.2-33 F-A Accepted By Evaluation (AR CA026894)

RHE-CE036 I03072 VT-3 22-36 F-A Accepted RHF-CE078 I03073 VT-3 2.2-37A F-A Accepted RHI-CEO52 I03074 VT-3 22-39 F-A Accepted RHK-CE008A I03075 VT-3 2.2-41 F-A Accepted RHM-CE005 103076 VT-3 2.2-43 F-A Accepted High Pressure HPA-CWE16 I03077 VT-3 2.2-44 F-A Accepted Coolant Injection HPB-CE013 103079 VT-3 2.2-45 F-A Accepted HPB-CE072 103080 VT-3 22-45 F-A Accepted HPC-CE059 103081 VT-3 2.2-46 F-A Accepted

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part D Page 4 of 4

1) Ownert Interstate Power and Light CompMy, Central Iowa Power Cooperative Com Belt Power Cooperative an Alliant Comwny Mao, IA. Humbolt, IA P.O. Box 351 Cedar FLapids, AL.52406
2) Plant Duane Arnold Energy Center, Palo, IL 52324 3) PlantUnit #I
4) Owners Certificate of Authoization (iftrequired): WIA 5) Commereial Service Date: 02101nS
6) National Board Number of Unit NIA Gross Geating Capacitr 614 MWE COMPONENT AND WELD EXAMINATION IDENTIFICATION RECORDS CLASS 2 ISI ASME XI Component Description Report Examination ISI ISo Categoy Results Core Spray CSB-CE029 103083 VT-3 2.2-49 F-A Accepted MT C-C Accepted CSB-CE064 103084 VT-3 22-49 F-A Accepted CSE-CE049A 103085 VT-3 2.2-52B F-A Accepted Main Steam MSA-CE025 103086 VT-3 2.2-53 F-A Accepted MSC-CE029 103087 VT-3 2.2-55 F-A Accepted MSE-CE033 103088 VT-3 2.2-57 F-A Accepted Scram Discharge SDS-CEOO1A I03089 VT-3 2.2-60 F-A Accepted SDN-CE00IA 103090 VT-3 22-61 F-A Accepted Reactor Core RCB-CE006 I03091 VT-3 2.2-62 F-A Accepted Isolation Cooling MT C-C Accepted RCB-CE008 I03092 VT-3 2.2-62 F-A Accepted CLASS 2 PRESSURE TESS ISI ASMEXI Component Description Report Examination ISI ISO Category Results THERE WERE NO CLASS 2 PRESSURE TESTS PERFORMED DURING THE THIRD PERIOD FOR THIS OUTAGE.

I IWE COMPONENTS ISI Exam ASME X Component Description Report Method ISI ISO Category Results Diywell DRYWELL STAB #6 103110 VT-3 N/A E-A Accepted DRYWELL STAB #6 103110 VT-I N/A E-G Accepted (Bolting)

DW INT 742'-757' SW I03108 VT-3 N/A E-A Accepted DW NT 757-776' SW 103106 VT-3 NIA E-A Accepted DW INT 776'-798' NE 103107 VT-3 N/A E-A Accepted MOIST. BAR. 742' SW 103109 VT-3 N/A ED Accepted DW ACCESS HATCH 103111 VT-i N/A E-G Accepted TORUS BAY 15 103112 VT-I N/A E-C Accepted

TIIIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part E, page I of I

1) Owners: Interstate Power and Light Company, Central lowa Power Cooperative Corn Belt Power Cooperative an Alliant Company Marion, IAL Humbolt, L'L P.O. Box 351 Cedar Rapids, LA. 52406
2) Plant: Duane Arnold EnrgyCenter, Palo, IA. 52324 3) Plant tUnit: #1
4) Owners Certificate of Audhriztion (if required): N/A 5) Cosma ercial Service Date: 0210 1l5
6) National Board Nurber of Unit N/A Gross Ge ierating Capacity. 614 MWE ADDITIONAL EXAMINATION IDENTIFICATION RECORDS Class Component I Previous ISI ISIReport Examination l ASME XI I Results Examined Report Number Number I I Category I THERE WERE NO ADDITIONAL EXAMINAIONS PERFORMED DURING THE THIRD PERIOD THIS OUTAGE SUCCESSIVE EXAMINATION IDENTIFICATION RECORDS p Class I Coinponent Previous ISI ISI Report Exam ion ASME X Results

-.Exmied Rot Numbes Nmnber Category I THERE WERE NO SUCCESSIVE EXAMNATIONS PERFORMED DURING THE THIRD PERIOD THIS OUTAGE

THIRD TEN YEAR INTERVAL INSERVICE INSPECION REPORT March 31, 2003 through April 20, 2003 This page intentionally blank

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part F, page I of I t) Owners: Interstate Power and Light Company, Central Iowa Power Cooperative Corn Belt Power Cooperative an Alliant Company Marion, 1A. Humbolt, A.

P.O. Box 351 Cedar Rapids, L 52406

2) Plant: Duane Arnold Energy Center, Palo, LA. 52324 3) Plant Unit: #1
4) Owners Certificate of Authoriation (frequird): NIA 5) Commeial Service Date: 0211W5
6) NationalBoardNwnberofUnit: NIA Gross Generating Capacity 614 MWE ABSTRACT OF ASME SECTION XI REPAIRS AND REPLACEMENTS Ihe repairs and replacements addressed in this report were performed in accordance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section Xl, 1992 with the 1992 Addenda (Ref. Relief Request NDE-R015 Rev. 1).

THERE WERE NO ASME SECTION XI REPAIRS OR REPLACEMENTS COMPLIETED UNDER THE THIRD PERIOD. ALl REPAIRS AND REPLACEMENTS WERE COMPLEIED AND SUBMITED UNDER THE SECOND PERIOD OF THE THIRD TEN YEAR INTERVAL

SUMMARY

REPORT.

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 This page intentionally blank

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part G, page I of I

1) Owners Interstate Power and ligt Company, Central Iowa Power Cooperative Corn Belt Power Cooperative an Alliant Company Marion, LL Humbolt, LA P.O. Box 351 CedarRapids, IA. 52406
2) Plant Duane Arnold Energy Center, Palo, IA 52324 3) Plant lJnit #1
4) Owne Certificate of Aut ization (ifrequired: N/A 5) Commercial Service Date: 2,1 75
6) National Board Nuber ofUnit N/A Gross Ge ieratng Capacity: 614 MWE Form NIS-2's THERE ARE NO NIS-2'S INCLUDED IN THIS THIRD PERIOD

SUMMARY

REPORT.

THEY ARE INCLUDED IN THE SECOND PERIOD

SUMMARY

REPORT.

I THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20,2003 This page intentionally blank

TIIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20,2003 Part H, page of 1

1) Owners: Interstate Power and Light Company, Central Iowa Power Cooperative Corn Belt Power Cooperative an Almnt Company MarionIA. Humbolt IA.

P.O. Box 351 Cedar Rapids, LA 52406

2) Plant Duane Arnold EnergyCenter, Palo, 1A. 52324 3) PlantUnit #1
4) Owners Certificate of Auhrization (if required): N/A 5) Commercial Service Date: 02101/7S
6) National Board Number of Unit: N/A Gross Generating Capacity 614 MWE ABSTRACT OF CONDITIONS NOTED AND CORRECTVIE MEASURES TAKEN:

The corrective measures are addressed in this report and were performed in accordance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code,Section X, 1992 with the 1992 Addenda (Ref. Relief Request NDE-R015 Rev. 1), and the Duane Arnold Energy Center Updated Final Safety Analysis Report The corrective measures performed as Repairs or Replacements are listed in Part F of this report and are documented, using Form NIS-2, in accordance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section X, 1992, 1992 Addenda. Specific details and associated records of additional corrective measures are on file at Duane Arnold Energy Center. The corrective measures addressed were performed during the period of March 31,2003 through April 20,2003.

TIIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through Apnil 20, 2003 This page intentionally blank

THIRD TEN YEAR INTERVAL INSERVICE INSPECnION REPORT March 31, 2003 through April 20,2003 Part I, page 1 of 52

1) Ownems Interstate Power and light Company, Central Iowa Power Cooperative Corn Belt Power Cooperative an Mliant company Marion, LA. Hunbolt IAL P.O. Box 351 Cedar Rapids, IA. 52406
2) Plant: Duane Arnold Energy Center, Palo, IA. 52324 3) Plant tJnit #1
4) Owners Certificate of Authorization (ifrequired): N/A 5) Comm ercial Service Date: 02101l5
6) NationalBoardNumberofUnit MA Gross Gel icrating Capacity 614 MWE ISI FIGURES AND ISOMETRICS PLEASE NOTE: ISI Figures and Isometrics are listed in Part B and Part D of this report

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part I, page 2 of 52 This page intentionally blank

Part I, Page 3 of 52 180a VESSEL STUD, . . AND LIGAMENT LOCATION Figure No. 1.1-05 PR-P rssnre Rteining 8vlgawent s i*ns L- oS e n

_ _ ORAWING RELE RE-v RTE PREPFIRED1 - REVIEOE RPPROVED PURPOSE j r I =ilL CHL RCM ISO S F-OR Ead 1 YERR PLRH C 9-2-91 OR CP t KK 10'S TO CD FORMT RS Pt NS-6TGUI

~~ fts"M I ons 6PF cal t CN we,,COMUM IEMIMM L-%VMV 4 7-.22-)4 DA FED GP REVISED PER ISI INSPECTION WALKDOWN

  • SS

?- OA _ _ DF DELETED DWG PER OURF-013 3/11/9og JA I TAK GP RE-ISSUED PER DURF-0025 GlEC tSERVLCE INSPCTION RASE SECTION XI ISOMIETRIC

Part I, Page 4 of 52 J'4OA 4 J3 J2 N 3A J Ifl EL. 924'-2 J5 1- DWS4 DW541I

-- MIN STERM "R" msA-DW44 D C St 2 0 , 6" 0w34e ISO. NO. 1.2-01 P&1O SI-lhiq RPEO-82 1.?

O340 DW240 W240 I (ST I I(TA TUNNEUL ......

J13 I'

-OR J13 K J 0 J2Y-XHR-2/ Ji 2 GU Or LUGS iI-t EL. 72'-13'J32-11/

CONT. ON I SO. NO.

2. 2-53

- ON NTECRAL 0* - FLOW ELEMENT LINE DRAIING RELEASE RECORD REV 2

1 GATE 3-6-86 v i-07 PREPARED f.

1 REVIEWED (1

APPROVED RCH ISO'S FOR 2*d ISO' T C PURPOSE 0 YEAR PLAN FORINT RS PER N-S3-079S I 3 7-422-t9 Ior P REVISED PER ISI INSPECTION WLKDOWN 4 1-18-9S TAX J _ GP REV. PER OURF-0018 3-21-96 JAN A P REV.PER DURF-UW027

_InmI I -

OREC INSERVICE INSPECTION ASME SECTION XI ISOnETRIC

Part I, Page 5 of 52 Dl

- NON INTEGRAL - iU. Ni I

- FLOW ELEMENT LINE 2.2-54

_ _ ORAW ING RELERSE RECORD REV DRTE PREPARED REVIEED RPPROVED PURPOSE I s-6-86 -L4L RCm ISO'S FOR 2nd 10 YEAR PLRN Z io A~Idi IG O'S TO CAD FOfttT S KER C-80-t7sT I _____7 _______ E____JB GP REVISED PER ISI INSPECTION YALKDOWN 4 1-8-96 TAX JW GP REV.PER OURF-0IS 5 3-21-96 JAM DA GP REV.PER URF-U0027 OREC INSERVICE INSPECTION RS17E SECTION XI SOnETIC

J1~~~~~~~~~~~J

_DW430W4SEELRTRR"(B DW3D3430FIA- FI40B I JIB ~~~BP-01

  • Jig~~~ig BP BP402 OLR- BP-~~~DW405 I ~~~~J3?R~~

L

  • - NO IWTERRLI1SODLANO.B11S2P-05

_________DIII5RLNERCR RE isT PRPRELS VIUED RPP2VE PUPOS 5 3- 21 JL D O REIEDPRigF-0

  • 6 DA3/26/98 OP~~~~~ REVSE PE340-U4

Part I, Page 7 of 52 IN, SS, CS 8" ISO. NO. 1.2-08 P&IO ISI-MI21 BECH OWG* OLR-8-1-H

- N NON INTEGRAL DRAIING RELEASE RECORD REY DTE PREPAREDI REVIEWED APPROVED PURPOSE I -lZ-66 S , ML RCr ISO'S FOR 2n 10 YERR PLAN 2 q-150oC tSO S TO CR0 FORMRT AS PER G-83-07S4 I 3 _-22-A _ JAH ss BJB REVISEO PR ISI INSPECTION ALKDOWN

_ _ _ _ _ I _ _ _ _ _

DAEC INS£RVICE INSPECTION ASME SECTION XI ISOMETRIC

Pa"t T. P0p R f 9 z

-J CC0 0 Ld -4 a

(I Ld 11 o o

CM _ 3

- (I)

U) C) c) Na s-eu

.4 W LL LU '-4

)

fa- zd '

I:

I_ C 7, a

LOU, I I (n ()

  • L.) 1

-4 I

cc 0

I

/

_. If c %C -., /

11% °S

- NON INTEGRAL

__I NG RELEASE RECORD REV CORTE PREPARED REV IEI4ED APPROVED PURPOSE 1 3-12-88 RCtl ISO'S FOR nJ 1 YEAR PLfN Z 1,".io (IJ f- (c 41 ISO'S TO C FORMRT s PER RG-83-87T3 a I-- 14 15A M~e GP RE=F0PRIUNPCINWL0W I I I I._I I I I L -L--~~~~~~~~~~

=- I_1 mmw6~~ 1 1 nRFC TR*VItCF rRPFCttnN RF SFCTlnN X ISEnKTRIC

Part I, Page 9 of 52 REACTOR WATER CL SUCTION (IRT )

CUR-SS, '+

ISO. NO. 1.2-- 1 R P&ID ECH-M127 BECH DJG# OCR-S-1-H V27-i 39 veT-135 J11 Jie J12 FROl 1.2-14 \ HDR-J35 1So 1.2-32 2S-DCI-7

  • - NOW INTEGRRL DREC INSERVICE ISPECTION HSfE ECTIOH MI ZSOnETRIC

Part I, Page 10 of 52 J13 EL S09' K20 oW330 ci

'k

_ X-39 EL. 782' CONT. ON ISO. O. 1.2-12B P2,IS ISI-t1 17 BECH. 14G D-6-1-H FlAuimn i FAUF 2:rcnan R£V DATE PREPARED REVIEUED RPPROVED PURPOSE L.. 3-13-8L AL RCII ISO'S FOR 2nJ I YEAR PLAN Z 1 Z5.Zo lAli f.1 Stt^o150,3 TO C FORMIT S PER NG-89-97vt i 3 7-2-94 JAH / FED JA REVISED PER ISI INSPECTION ALKOOWN 4 7-G-95 DA JF GP REVISED PER OWF-0013 OREC NSERVICE INsPECTIaN ASME SECTION XI ISOMTRIC

1D.- T 'D--, I I -9 cq I

I r o U

O= ua

- 1 II l w m

-) cr (s

N cl 0

a:

LL LO CE Vq-4 Z.

I U z

cr-0 Lf) uj U I

LdJ U) (I)

(I) *II

-i c

a z

z I

__DRAWIING RELEASE RECORD REV DRTE PREPARED REVIEWED APPROVED PURPOSE I 3-17-86 L L RCn ISO'S FOR n 10 YERR PLflN Z cqi-q-o 11j [ _ _ IiSO' s TO CRD FORRT RS PER HG-8S7SMi 3 'VA JAH / FED GP REVISED PER 151 INSPECTION WAl=DOWN OtEC INSERVICE INSPECTION Sh! SECTION XI ISOMETRIC

Part I, Page 12 of 52 Z-V3O.j0Z 4= r- C4 A

-C U c SI-al OSI co M-'

zr

' W -3 mis b a- a.

co

-A (t5?

M' 11<-H nr,*n 0

-3 F, 3 =-

m %

cu uC2 coX I I

1 I r* u ) * -. i CU -

cu Id.

Cs i'-

li i ~ _. 1 6l:~~1 lu :,_ >_ , EA r4

a ~~nm

, -a5!

I- r u~

b2 Z~~~b m,_

ID rF >SZMC cm F

o~~~

CC~~~~C S g Lii UF 2 I a

CA= ItILI o En~~~~c I -4

-j cm at Oa G Cn ~~~~~ I~~~~~~W a

._4 > CY fu -7 t- cu ~ ~ Ju

-W cu L1J - c~

VIB

-J Cl) cn c c4 Cu

-,CD~~~~~~( (0V

~c 0.M co

-) C -

'-7

(-I cr r

,rp 4

Ld

-C-0 0.l~~~~~~~~~~~- _SF o I C' Olco

'A- co e 0) 3 L0:z CC )

I) ,'n *i co

-UB (0

C W Wr 9U.0

_ Ci I-o m u aa _ c I Z I-

-,-- I -

c aa a~~~~; 40 Enm il -1 2 U)

I Ca" _" I Ca co 0.

-- _ORRUINC RELERSE RECORD REV DTE PREPAREO REVI EWEDO flPPROYEO PURPOSE 1 3-13-US SlL 3f1L RC8I ISO'S FOR 2nJI 10 YEAR PLAIH Z 9-a't-9e - KK_ 1U' 5 TO CRO FORMAT ns PER HC-8s-G3TS 3 (A 4 ZL.2-. J-RODEO FLRI- E 4 7-22-94 MA - FEO P EVISED PER IS1 lNSPECTlON AUKWN 5 7-6--Z DA _ JDF GP REVISED PER -_RF-0013 63-18-196- YAK _ w_ _ Csr REV. PER DtF-0 _ _

CREC ISERVICE IECTION B61fl SECTION XI ISOIETRIC

Part I, Page 13 of 52 03 uI

()U- 0 IL a: 0 QM (

-I~~~~~~~~~0 S.~~~~~~~~~~1 a"U~~~~~~~L cm C3 0 ~~~~~~~~~~~

LL~~~~~~~~~~~~~~~~~~I DREC MItERVICE gmISPCC'roJ RE SECTION XI CtSflE1W1C

Po H

RMR-JI I 'd RhA-JI H pa oQ REC IRCULATION MANI FOL D "A" & RISERS E F G H RMn -, RRE-t. RRF-l RRG I RRH- 0 Luh Ln Ss, IG1 ,ID BECH-Hl16 10 /

A~ PWM-2-9

... 3 - _

I SO NO. 1. 2-20 I

moppl-

Part I, Page 15 of 52 DRAIN LINE 2" S S. RDB I RECIRCULATION " B ISO. NO.

PI1 BECH-hI16 1.2-21B FSK-OI 69

  • - NON ITECRSL noFu tairC cI cmcc Dnernon REV DOTE PREPARED REVIEWED APPROVEO PURPOSE I -ei-s6 _ RCM ISO'S FOR 2i 1e YEAR PLAN E j1-10O ___ %______ TO CR FRInT S PER HQ-83-OT3I
Z -7 2 9 _ ___ I_ P R I 3 JH D GP _REVISE0 PER IS1 INSPECTION WA;LKoowN DMEC ISERVICE INSPECTION SME SECTIO X IsoETRIC

Part I, Page 16 of 52 I

CRT B-G-2 ITEI1 97. 1 ["I vr- 1 BOLTISNG, NUTS )

8 STUDS 16 NUTS

- J2

`~D N7 HEAD VENT HVA-CS, '"

ISO. NO. 1 . 2-24 P&ID ECH-11'I IPEO-81 1-2655-19'4-3 ORRING RELEASE RECORD REV ORTE PREPRRED REVIEIJED RPPROYED PURPOSE 1 3-26-86 4ML RCH ISO'1S FOR 8nJ 18 YERR PLRN 2 iSlZ4-q0. SW

- 4fl!1 isa S TO CR0 FDOXRT RS PER NG-I9-9T31 I 3 94 k JAM FE0 GP :REVISED PER ISI DASPECTION WALKOOWH I -_ -l I Ll DAEC INSERVICE INSPECTION AStME SECTION XI ISOnETRIC

Part I, Page 17 of 52 c DCA-13 K2A J8 A- 90~/DC-2~ 7JJ J14 /1"1 -

13-ICA-13 3 J12A ile X~~~~)IA FSK-03734 iC~~~~a ~~J17 FS-33 j GR ig F7348

.OW210 K7R dMH 5tLV R J22_ _ J19 v-2E-8 ) >(i? fSK-03734 P&IO ISI 11126 FSK-0331'S 03992 j22' J2* - NON INTEGRAL qi J2 3 STRNDBY LIQUID CONTROL 3/4'-DCA-12 s. 1 1/2", 2 41 ISO. NO. 1.2-27 CREC tIISERVICE INSPECTION RSMIE SECT30 X ISOMIETRIC

Part I, Page 18 of 52

\1 I/

RECIRC. PUMP " B VIEW SUPPORTS A-A RPB FIGURE NO. 1.3-03 /K\ -3J

  • - NON INTEGRAL T~~IM DREC INSERVICE NSPICTION SME SECTION X ISOMETRIC

Part I, Page 19 of 52 I L l

Part I, 20 of 52 I

-I 4

a Is I.-

a en w

9 <C

-J (L

SECTION A-A PLAN VIEW WELD PER -

WPS-103-1F5 or WPS-143-IF5F7 3/4 =- --

ELEVATION REFERENCE DRAWINGS:

APED-B11-001e4>, APED-B11-2655-168 IES:

Inservice Inspection Program Reactor Pressure Vessel Sketch

Part I, Page 21 of 52 L

j I

a Ii PLAN - VIEW CE

-r-

-4 z

C (r,

LaL PLAN a:

w 0- ELEVATION w REFERENCE DRAWINGS:

a: APED-B11-001<4>% APED-BI1-2655-169 XIIES: FEEDWATER SPARGER c Inservice Inspection Program BRACKET 7 c Reactor Pressure Vessel Sketch OWG. NO.

VS-01-27 I2REV.

Part I. Pate 22 of 52 L

-2 a

I i 3 w PLAN VIEW WELD PER -

WPS-305-1F5 PLAN VIEW Ct)

VESSEL FLANGE SEALING SURFACE 2 5't0 I

0 0

I cc 0- II II 4- trSS OVERLAY U I I w I I Ct)

(n 2 I1 I C

-j ONE LAYER 5 *-OVERLAY PER La.

WPS-103-1F5 w

0 ELEVATION 0

w U. REFERENCE DRAWINGS:

tL APED-B11-001<4>,APED-Bll-2655-171 cc 7

fI. z-IES:

Inservice Inspection Program

__ Reactor Pressure Vessel Sketch GUDIO GUIDE RCE ROD BRACKET VS01 C1 OWG.NO. REV.

Part I, Page 23 of 52 L

"I PLAN VIEW ER-305-IF5 Iu t 0X LAYER PER WPS-103-1F5 SECTION -A

- Ws'OVERLAY

  • -ONE LAYER OVERLAY I

ELEV. 602Y i

A A 2

C J

La.

REFERENCE DRAWINGS:

APED-BII-001<4>. APED-811-2655-170 ELEVATION I ESSTEAM DRYER c,im Inservice Inspection Program SUPPORT BRACKET 77 cReactor C

\I Pressure Vessel Sketch w. NO. VS-01-29 11REV.

Part I, Page 24 of 52 L

Cs 3 T R a

_a 0§ X

CY, PLAN VIEW-TOP HEAD z=: ib La_ HEAD FLANGE SEALING SURFARE I

ELEVATION VIEW (I

WELD BUILD-UP PER WPS-103-1F5 or WPS-143-1F5F7 \

x a

0 z

0 U I~~~~~~~~~~~~1 4 ID w

a.

Ct) z z C

-j VI w

w WELD PER WPS-305-1F5 0 WPS-103-1F5 U-w SECTION A-A I- REFERENCE DRAWINGS:

APEO-B11-001<4>%APED-811-2655-172 C

114IES: STEAM DRYER Inservice Inspection Program HOLD-DOWN BRACKETS 7/7tEc Reactor Pressure Vessel Sketch WO. Vmv.

U~~ ~ ~ ~ ~ ~ -V - 13

Part I, Page 25 of 52 L

C; I

c I.

d C In I-9; a

PLAN VIEW

_ _i z

C, SECTION A-A vi REFERENCE DRAWINGS:

APED-BII-001<4> APED-B11-059. ELEVATION I APED-BIZ-067, APED-B11-2655-198 IE _ SURVEILLANCE nk:Inservice Inspection Program SPECIMEN BRACKET Reactor Pressure Vessel Sketch DWG. NO. REV.

Part I, Page 26 of 52 L

0 9

I 21 I21 1

I PLAN VIEW 0n BUILD-UP PER 0 do 61' WPS-103-1F5 o-U. WPS-143-1F5F7 I I~l~ I_ 6'

-~_ I - 1 B f _ B OFF I

4

'>tI r X, -, L

-j t , - .1/

U)

N Ii

- _ _~

w SECTION B-B z

C -j w 0 ti.

VIEW A-A REFERENCE DRAWINGS:

APED-811-001M4>. APEO-B11-2655-167 f3w IES: JET PUMP RISER

! c Inservice Inspection Program SUPPORT PO 7I~t7) Reactor Pressure Vessel Sketch owGNO. Rv.

Part I, Page 27 of 52 I

a:

3 0

Q ra N4 I? "3 en, N 1

21, LA F) nf I 0 3-.

pi I

pi -J a- gn E

v cn cn 0

C C

U Ua 0

0 tr REFERENCE DRAWING:

U, APED-B11-2655-;04 e VS-01-071A WI

-36 2 I_ aIES: SHROUD SUPPORT CO^,c Inservice Inspection Program ASSEMBLY 7 _c Reactor Pressure Vessel Sketch NEW VS-02-10 R2 I-

Part I, Page 28 of 52 L

<WELD BUILD-UP AS REOrD. PER WPS-309-2F43 SECTION A-I S

, ORIL & TP %-13 UC 2Bx)I DEEP th a (A2 %a MANHOLE PLUG is C2 m

I X!

w I

xC el (I

(n C

.e C

2 C

IV Is IL La.

tr C

LL W

REFERENCE DRAVDI3S Th IL en ISO AED-BiU-2655-2n, APED-1-205-205 cc APW-W-265-265 InsIEcSPLEDGE SEGMENT Inservice Inspection Program PLATES i tReactor Pressure Vessel Sketch mm.* VS-02-11 R2 K

Part I, Page 29 of 52 d

Cs 0.

i E

is

( TYP.)j I I U,

9 i

2 I0 270' IL C

U- U 0_ -i U.

v-2 C

LjL REFERENCE DRAWING:

APED-B11-3084-008, APED-B11-3084-009

- I J ES:

IN _Inservice

_ Inspection Program CORE PLATE 7I7I7fd Reactor Pressure Vessel Sketch DO.

I~ V-3021 NO. TREV.

K-

- ~~~~~~~

Part I, Page 30 of 52 L

I i

4 a5v v9 I.-

- w-j 2

A9 H

0, a-Ui.

03 (A

.500 DI 2

C 2.56 REFERENCE DRAWINGS:

APEO-B1-3084-008, APED-Bll-011 7Vi- IsnpscrtVessel Reactor Pressure og a m ow No.

iv ine PISketch ERIV 3 0 L UEL SUP OR REVEV SR .

~,-- \<jD I 1

Part I, Page 31 of 52 199I m -19 SECT1ON C-C REF) 4

.I

.z.

w C M~~~~~C 7 REF)

- ----_- ll 7ffF E- 3in a- =

J SECT[ON A-A LI~~

I-C

._ aJ CL I- Ua 1/ \d

- ZASi' 11 I _12 _

A A4.

'A4 1tJ; - 14A I - -1A Al

- I 1

txm-11AI /,Ad d A A~ I i

' ,- 't

-a- .- * -a- i-I Y.7.

V.-a C

c La.

,Lf' npwT li~iT-C.

Ih.ILI 11 IIIWI£$ tL.IM'I T .62

.50 l00 RFFRF APED-B11-3084 -021, SECTION B-B APED-B11-3084 -108 jJ w4IES: TOP "MrInservice Inspection Program l GUIDE 7 " - ]Reactor Pressure Vessel Sketch Id.NO. REV.

F_

I I L e _ I I . . . . .

I I I I I 8/8/95lREVISED PER W/a/2-951

/lN.H2-0q-q4 IQRFT~Fn FnR VFc~rFl URF-0011 VESE FO -DAFE __ ...

TNqPF(rT~nm PRflflRam G A DI DNPC~nGO SS SS l No. ESCRIPTION BILL OF AIL. PROCE.

-IMSIDF lOP ISI I HAN _

7REV

_. _ . vw . ^vvl .

N071 DATE! tD TR CHKOII DR. I E I 2 PIPE 3 CAPSULE BASKET

?

nI as 4 NI1 SUPPORT BCKET PLAT 304 SS -

5 llLI__

OLT I 4 I

(;4 0 z 0 1L54 Z

aCP 4

.825 SD - /

M1='-- -Er~

BARI 9 ig 00 ~~~~~~~~I ,

I Gt " E 0 0 Ui r ,I.I II l

I I

I--

VIW D-D V VIEW C-C _VIEW E-E VIEWB-co D

rHo 3

U, r I- I Im 123..9- (WITH PRIN AR AVTh 93 I'd I m rt I 126 S 40 PH - H 0

N r-0 m

1111 A W -- 4.

V-- g-93 so 0

63.50 0

115.37 SPRING RELAXED l1h NMc mm 7-

Part I, Page 33 of 52j oc 7.375 0L co ()Cfl)(fls C-0 U-oLii

<1~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

I-A (n

-Li

~

U.),-~ ~~~~~~U REEEC RWNS

a. PDB112,AE-1-2 z

0 nevc npcinPormC0GiETB N eco rsueVse Sec W.N. V-24RV

__ _ _ _ _ _ __ _ _ _ _ _ __ _ _ _ _ _ _2 _ _ __ _ _ _ _ \__

Part I, Page 34 of 52 Co-s CR-S E

I 0 SHELL - REACTOR UATER TUBE - COOLING WflTER

. 2.1-01 ORAWING RELERSE RECORD REV DATE PREPARED REVIEIJED RPPROVED PURPOSE 1 '-26-86 SAL RCii ISO'S FOR 2nd 1 YEAR PLAN Z 9 qO I J- J - 150S'5 T0 CrD FRIHRT RS PER NG-89-879Y B s I____ _ FED W _ _V EIS PER IS! INSPECTION WUM M 4 3/4/97 JAN tAK GP REVISED PER DURF-0036

_im m OREC INSERVICE INSPECTION SHE SECTION X I5~nETRIC

U OW007 I . RB031 BP1804 rti (TORUS BASEMNT) PEIC (SECR)

£

- ZFI-Nl I

.0 N1 cp

.0 CE-5e Ly1 i 0I" ACF-6 E-L PE I-9 CDs BP07 A,8__a _-2 CONT. ON BP1805 C-57 CF-55 t S (TORUS C-I C- BASEMENT)

ID CF-5A-i5*

4- c-a1 C-0  ; LJCFa CF- 12 BP2075THBP1807 CF-

D CF-?SCF-39 CL z

rn CF-75 0 40 c 3CP31CF-?

~It n lk~ ~~ ~ ~ ~~F3G *.CF- CF-21

!a 3 m

.I :D D CF-18 CF F1 a CF-'

- 'I"LIE) I-29 Ii C_ a1 m rr rn c,

.c,e4 crI i

1=

C

- 0 -t O

3 _ .~~~~~CF-74 r -3 CF-G S E rr x

, .4IaU C c CE-66 BP1802 BP1810 C10S CF-7 CF-6

! Iiia -r I4 Ir I

Z 0

CF 72F-7 BP1801 RHR PUMP SUCTION ( SE. ) qIV iON to P1 'p CF-72I II1 n onr T VI i X WM LL rmrl A HI j _

- NON INTEGRAL

  • - EXEMIPT < / -,, CSi 14" & 24" i *** - INST. LINE
3 o
        • - PSV LINE < 1) ISO. NO. 2.2-32 pO isi-nia I _ BECK. WGI -712-H I ImEEEIEI.ImI.I.I-

I~~~~~~

I-------------------------------------------------------------------- Part- -I-* -Fag& 36 -of --------

I m I I c co ea- 8H-Ih U. ~ ~ A a CD DILD l a C4 a'

CS -.C IO L.I I C aw~ ci W~~aI~

00 cu CD '~~~to a tI -Jx U,~~~ ~

~~ ~ ~ ~ ~~

U ww 1CD C D - z~~C C,)

5( 1111 -0 co 'P

.6W In ie: a.m z

X CuY) 0 11 x

'-4 (U0 C-j z 0~

U

-j C; LL U,) U)~ 0 3 C-)

ORA INC RELEASE RECORO REV ORE PREPARED REVIEUED RPPROVED PURPOSE 7 604099 DA GP FED REVISED PER DURF-U-0111 2 T Iq:- E FM ISOS TO CAB FORMAT AG PER NC-99-97S' I 3 7-22-94 DA FED GP REVISED PER IS] INSPECTION WALKDOWN 4 7-6-95 GA JDF GP REVISED PER URF-0013 5

  • 2-2-96 TAK JW GP REV. PER DURF-0018

~~-q I _A I _ G F.PE LR-O2 URIC NSERVICE INSPECTION SSIE SECTION XI ISOMIETRIC I

Part I, Page 37 of 52 CD cu CID 0 xw U ze "LL ui U .4 (1: LU (D co tu J J. cn U I a w

x LL C, cu cn m I J W CD CU w m 1.4 Cu LI' t--, (-U

-J w LL *a (L LLI cri I -J UU. Cy-:t 0 CL E; V M D- cu z CL LL. w cu cu W(U qu Li U,, J. I I LL. LL I C. CD L) C.) Cj (j IL. C AL L)

Cu LL 3: W (f) M co IIL cu 1

LL. wo z

cv cu LI -4 m -J a%, AjtL 9L ci I %01 LL

.rl Im 0 g- C ul U 9L cL LL ni cu cu I U U m Ld Lu _J Qx0w u) w x

(A U

J 0% >

LL)z 4% ^

Lml w z

-J (10 x

C) r I cuI I

-4 0

U LL L6 LL, :9Li J I r IV) tp cn ED LL.

U m cu 03 Lip 49

%30 im t-LL V- W 451%Z15 COM C3 8-8I cu J. w C- w di. 0 CO W I I cn CD LL.

WL) U to ulj

&L U LLI%  % Il.

Li U U Ica 0

w C, V) co CD M r- co V)V T oc tv-) I'm L'a LIL. LIL. W IL. Lij -J coco LL. L" J ci LL4L V L) C.) U C.) cu cc

.J cr g- U cu 0) m L) I I L x ou LL LL 0 LLI ul 10 Cli cu cu UL ORfUWING RELEASE RECORD REV DATE PREPARED REVIEIED APPROVED PURPOSE T SPL SrIL o-2-86 RCn ISO'S FOR 2nd 10 YEAR PLAN 2 9-ia-se OR GP KKI 150' TO C FORMT fl PER KG-68-M't 3 5 I O _FR _II PCX E ROOEO WELD CF-413i CIITEO ON REV.2 4 722- 4 .DA_ JAH _ OP FEV1SED PER DS1 INSPECTN WaJdQWN BS 76-q5 DA JOF GP REVISED PER URF-0013

z-TAK J EV IRM S"_ __

DREC INSERVICE ISPECTION SJIK SECTION XI ISOIIETRIC

Part I, Page 38 of 52 FM CONT. ON ISO. 2.2-52A ACLE (EXEiMPT 13Y MIWC 12 f)c a' I ~~~~I' z DW003 1a  ; W0 ' l;_a cmu ,

_ U. 139l rs scF Wz -Cs-l~~~~a W X § -ca t CE g 12 in gs 2ou

-_4 I "-Zk CF-80 CF-59 CF-5;8 CF C -S U '

ZgC, al CF-57

-4I CE-56 0-5s l ~ CF o1~~~~~~r lL8CF-'

2-38k;2O 9 CONT ON

- o ISO.

F_^-s L CB-.2.2-378 REF, OWSS,

%/ -~CF- 101 S2 4119 AND I$BC"7X F-102 ily

_-1as 4 LUGS RHR HEAT EXCH.

c0-a5 DISCHARGE (SE)

CCE 7 - GBB- WELD PREFIX RHF 1-8 G3-5/ CS, 2. 1 8 & 2 0

!! , t ISO. NO. 2. 2. 37R CF- I\ 1 CF- 12S TO ISO.

CF-128

, _ / ~~~~ st l X 't~~~~ LUGS ILA EL. 79

  • - NON INTEGRAL ( \

DRRUING RELERSE 2RFC011 REV I

OATE PREMAED

~i... ~ .....

,U- ZMM--TAC-j4 .. IIZ(~..........

REVIEWED 3L FLO__

A APPROVED RC"l

.139`SO ISO'S FOR 2nd 1 YEAR PLAN PURPOSE TO CAU FORMAT Al ER NU-85-ST lREVISED PER 16 ISECTION V.JDOVM REVe PER DUMF-0018 U4 GP REV. PER DW4WB27 b 1414w,01 UR I *P*Ur 8tViSWU Ih UUiF h-U~l4fS DREC INSERVICE INSPECTION SME SECTION X ISOnIETRIC

PoOtT Po___ -in -9 cq L)~~~~~~~~~~~~~~0

(-) r(v M CD - E l ) L U- I P.- zt- I- co

'LI I'll. LL. WL I I-eLI u LL ~ ~~~~~I II

-I~~~~~~~~~~~~~uI U. C;~~~~~~~~~Lu~-

U Z U)~~~~~~~~Lh

-i L3 L) 0I

-4I (J LL DRIIIN REES RECOR REV ORTE PREPARED REYIEWED APPROVED PURPOSE 1 6-18-00 SiL SCIL RCfl ISO'S FOR 2nd 19 YEAR PLRH 2 5-18-90 GPKKI1 P {SO'S TO CAD FORMRT RS PER NG-89-179*

3 1935j I~ ( IjI REVISION PER DOC 798 7-22-194 tBA _e GPREVISED PER ISI INSPECTION WALUDOWN 5 7-6--95 D JDF GP REVISED PER DURF-0013 I I OftEC INSERVICE INSPECTION ASSIC SECTION I 50NETRIC

Part I, Page 40 of 52 (3/4 SOC. )

CF-29 CE- / C0-31 (3/t SOC.)

CF-25 CF-0 I9 CO-24

,-Za CF-21 CF-19 CF- I VCE- 16\-23/

' LUCS CF- 5 CF- I I RHR HEAT EXCH.

DISCHARGE (NW)

DW214 (TORUS) WELD PREFIX RHK CS, 10" ISO. NO. 2.2-4+1 CF-3 1983 CF-Z EL 753' NOTE: P&IO ISI-Illl9 PIPING XCM /4 CO-I TO ISO. BECH DUI -721-H PER UC 50 - 2.2-¶0 SUPPORTS EXEIPT PER lF-2510a ORRWING RELEASE RECORD REV ORTE PREPRREO REVIEWED APPROVEO PURPOSE 1 s-2-s6 SL RCM ISO' S FOR 2nJ 1 YEAR PLAN a2 1-1 --q- ZZ n _ ISO' S TO C0 PORRT S PER NG-83-9T3 3_

7__ JAH S BJ3 OP REVISED PER ISI INSPECTION WALKOOWN

-4 1/24/%} TAK DA f OP REV PEUR ol-l

- - - __mI DREC INSERVICE INSPECTION RSME SECTION X 1SIETRIC

RHR FUEL POOL COOLING

& CLERN-UP WELD PREFIX RHM CF-49 Cs, 8" ISO. NO. 22-3 PIO ISI-lISs & 134 BECH DWG#

HB-25-1 2 3 5 Ct-5 I X RU3

. (OVERHEAD 3RD FLOOR P!PECHASE) 1 4

z In :X-a C~8 ~T'D20NI is18 2.2-34 0

In 6B1 N

x z0 AI'

-4 U,

4z 0W13 1

  • - NON INTEGRML (TORUS)

Part I, Page 42 of 52 I

Li z

0

_ +/-t

(.) I I MU W x ,_CUa ~C9 -

CL LL z Z wL

(' CuI- O r D- x (flX (D o31w 0

I.

z

'-4q I I

-"3

  • F- C] a _- o co ;

"6 0 I I Io) d Do DHEC NSERVICE INSPECTION ASM SECTION XI IHETRIC

Part I, Page 43 of 52 (U .4 I. .4 If (J 'O

.w a:_ _w..

m LO C.) CL m

t-(I) I C- O

~cu a x o-

.4 (U a)

QL ILL _X ev ~~~~~~~~~I -4 U -.

U.

U-4'

' O coF 0..

0Q. CU Z W I U r t

_ E (u a, 0 'U C)4 -J I U. In IU~ 3I Ui U3 CO (1) 0- 0 SI 03

-i If!I

-i a

w I-z 0

z I

DRRUING RELEASE RECORD REY DRTE PREPARED REVI EUED RPPROVED PURPOSE 7 3-21-96 JAH DA GP REV.PER DURF-U0027 98-1.8-9 I KKM Io' S TO C FORnRT RS PER G-63-UT67 a - kw qg&%T CORRECTING HANGER DENTIFICRTION 4 7-22-94 'VA JA J FED GP REVISED PER ISI INSPECTION WALKOWN 5 7-6-95 DA JDF GP REVISED PER 0URF-013 6111CV96 TAK DA REV. PER DURF-0018 DREC ISERVICE ISPECTION SME SECTION XI ISOlETRIC

Part I, Page 44 of 52 "a~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~c I~~1~~

L)~ 0 U I#w U CJ U.~~~~~~~~~~~~~~~~~~~~~~~~S a U~~~c Uc F~-4 (I CD) ILU

~~I~~J ca~L U~ coo C c IL a-,

ILb D C)~~~~~~~~~~~~~~~~~~~~f DRAWlING RELEASE RECORD REY QATE PREPRREM REVIEUEO IRPPROVED PURPOSE t 7-8-B RC" ISOS FOR 2n 1 YEAR PLAN a i- eA-§tS- X S C I'ORAT RD PER MG- 1tS-3?

= ._ _ s -go !XTW OC? PISS3 RoIIOVIRL OF CROSME TO RHR LINE 7-22-j4 BJs GP VISED PER ISI IWSPECTtON VAXD-OWI 5 I76-%S DA JD GP RISEDPER OF-001 mmI sI -aI.a:_ -

OIFEC INSERVZ 1NSPIC1IQ" nSnE SECTION Xi IWIEIEIC

Part I, Page 45 of 52 w

Un 0 -

_~~~~~ t ~~~~- 9 It too mAI (o U I:

S/ 11

]~~~~~~~~~S

~~~~

t-Z

~C 4~~~~~~

OWD) a Y t X.vQI X0 L9a6 IL~~~~~~) L

-~~~~4 (l 4c~ 10 cIL '

co U Ia. I- ~~~~~~~~~~~-,,~

UitL ~ ~ ~k C,~~~~~~)I CD co~~~~~~~~ILI

. Iu

- DRAIJ[NG RELERSE RECORD REV DATE PREPRRED REVIEUED APPRDVED PURPOSE 1 7-1I-s SML SlL RMCr ISO'S FOR nJ le YEAR PLAN

2. S-18-90 _I I 150'60 FrT ItS rER G-65-681S a L-Zi _ REVISED NUM8ER 4 7-22-i4 _ _ C GP REVISED PER ISI INSPECTION VUCCOWK 5 76-95 DA JDF GP REVISED PER DR-0013

_ I -A .u

.V. VW mb OREC IIISEtICE IMSECTION l5t$ 5ECTItm Xi ISOnETRIC

  • CD

- zz XW 0~~~

D O~~~~~~~~~~~~~

~~~J I LJ(U c U~~A In~~~~~~~~~~~~~~-c LL 1% .1 2. 1~~~~~~~~~~L

~

co~ ~~~~~o 2 ~~

'J-lI.'~~~O ISO'S TO CR0~~ FOR1L AS PE NC-89-579'*

- I - I~UlI o L1 n(n 2 x I I I 1 OECISRVC NSETONAIE ETONX SOiT2

9------------------------------------------------------------------- Par t- --P-ag-e- A,7--o f ---------

z

<r cr~c cnW ~~~U- U U.%

J. a~~~I o

- J~~~~~ JC U U 5'5T R ORIT 15IE (GU5-T

- S U,. 0)

I.11.

UrESETONX UECISEVCEISPCIO IOETI 4u MO (U~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-

Part I, Page 48 of 52 iI z I 9-I-4I I I O 12,

-4 1 t, t U --% 0 w

U C- u-u W) a  : LO I I L IL t i 4J -

C-)

0Q (I) th)

(U 0 0 EZ I Ca -

w -a a X (U Ca (U '2 l_4 nJ r

CC uJ I=

a:

0LI zo 2 I9

-4U U

n) X a CU z 0 Pa4 wL -J U 0 n en-

Cf) co0

<I 0 PA;~~~-

tLQ-) IL)i /~~~~

ILk I u T) I ~~~~~~~I

!z mw IIIJ U L L~~~~~~ul~

IL

/-I neuZ a~~~~~~<

I ID.

IzwIKEWUCD ~

cu Uo~~~~I~NU CD 7 i wl~~ ~ ~ ~ ~ ~ ~~ o

u. co~~~~~~~~~~~~~~~~~~~~~~~~~~~~~.

ou~~~~C Ul. I (U L)~~~~~~~I la L) 11 I I,-~~~~~(D (

0 1% ct,~~~~~~~~~c h z lu~r I z~ ~~~~~~w CO LLJ ~~~~~~~~~~~~~~~I GI I

co0~~~~~~~~~-

U

.1 w~~~~~~

______ ORRWING RELEASE RECORDr_

REV PREPRREO DATE REV[EUED APPROVED PURPOSEi I

- -~~~~~~~~~~~~~~~~~~~~~~~~~~~0C w~ ~ ~ ~ ~ ~ RCCSRIEKSECINf~ERCINX SITI

Part I, Page 50 of 52 HOR. (SOUTH)

WELD PREFIX SDS Cs, 10" & l ISO. NO. 2. 2-60 3/4m OLTS TYP OF TYP.

DETfIL 1 DETAIL 2 ORRWING RELEfSE RECORD REV DRTE PREPARED REVIEUEO APPROVED PURPOSE L 7-16-86 51L SMlL RCMl ISO'.S FOR 2nd 1 YEAR PLAN a ji-25-av JPM RCf REL MODOIFICATION OF SUPPORTS.

_ _ FCN^ v1323y J SE 5 3 Ii114*5*7ISO'$ TO CAD FORM AS PER O-09-37S

.4* 7-22-94 JAI1 F REVISED PER ISI INSPECTION WALKDOWN

- - I 1K I t IREV.PER URF0018 ODRC ISERVICE INSPECTION SI1 SECTlON XI ISOMIETRJC

Part I, Page 51 of 52 RB142 IRX 767'-'4NORT10 I0'-8m 900 RED. ELL SCRAM DISCHARGE HDR. (NORTH)

WELD PREFIX SDN CS, 10" & 8" ISO. NO. 2.2-61 BE, HISIH1_

DE1. I DETRIL I DETAIL DRfWING RELERSE RECORD REY DATE PREPMED REVIEWED APPROVED PURPOSE I T-16-86 SMlL SMlL RC7 ISO' S FOR 2nd 1e YEAR PLAN 2 10-tc-87 JPM RCI1 REL MODI1F ICflTION1 OF SUPPOR1S.

a 3 I17 - -- TO CD FORMAT IG OEV'S S PR 89-GT4 4 17229 ___ VA AH M G P~~~I CN 129i REYISED PR SEC ISI 116PECTION WLDW 19S TP44b IK IAREV. PE WF-00W DREC ISERVICE INSPECTION ASHE ECT3ON X ISOMETRIC

I Part I, Page 52 of 52 0

it)i CO a-0 00:

° it 0-a

. 4-I-Z U, OD o j

.- C DATE

[REV PURPOS PREPARED REVIEWED APPROVED nRAWIG RELEASE REqnRnl RZEX DATE PREPARED REVIEWED APPROVED PURPOSE I 3/20/16 MS JAH GP ISSUED PER OURF-B019

- - . I

_= -

~~- -.

THIRD TEN YEAR INTERVAL INSERVICE INSPECFION REPORT March 31, 2003 through April 20,2003 Part J, page 1 of 4

1) Owners: Interstate Power and Light Company, Central Iowa Power Cooperative Corn Belt Power Cooperative an Afliant company Marion, IA Hunbolt, Lt P.O. Box 351 Cedar Rapids, IA 52406
2) Plant: Duane Arnold Energy Center, Palo, LA 52324 3) PlantUnit: #1
4) Owners Certificate of Authorization (if required): N/A 5) Commercial Service Date: 02/01/75
6) National Board Nunber of Unit N/A Gross Generating Capacity 614 MWE STATUS OF WORK FOR TIHRD TEN YEAR INTERVAL (Those percentages shown are actual, where the percentages exceed the allowable only the maximum (50% for period one and at least 16% for period two) will be taken credit for).

I CLASS I ITEM NO. TOTAL # PERIOD I PERIOD 2 PERIOD 3 REMARKS BI1 4 0/0 0%/0 00/0 B1.12 8 0/0 0%/0 0%/

Bl.21 2 25% 50% 5001 BI .22 15 0%/0 0% 0%/

El130 1 50% 50% 500% See Note 7 ElI.4 1 33% 67% 67%

ELM5 1 0% 0% 0%

B3.90 33 48% 73% 73% See Note 1,8 B3. 100 33 48% 73% .73% See Note 1,8 B4.l1 2 0% 0% 0% See Note 2 B4.12 89 0% 0%/0 0%/ See Note 2 B4.13 30 0%/0 0%/0 0% See Note 2 B5.10 14 50% 71% 71% See Note 8 and 11 B5.20 8 38% 63% 63% SeeNote 11 B5.130 8 38% 63% 63% SeeNote 11 B5.140 2 0/. 50% 50%V See Note 11 B6.10 60 33% 67% 100%/

B6.20 56 29% 64% 100%/

B6.30 4 100% 100% 100%/

B6.40 60 33% 67% 100%/

B6.50 60 33% 67% 100%/

B6.180 2 0/0 0%/0 0%/ See Note 3 B6.190 2 0%/0 0%/0 0%/ See Note 3 B6.200 2 0/0 0%/0 0%/ See Note 3 B7.10 3 33% 67% 100 B7.50 5 20% 20% 20% See Note 3 B7.60 2 0%/0 0%/0 0%/ See Note 3 B7.70 47 4% 6% 8% See Note 3 B7.80 89 15% 15% 15% See Note 3 B9.11I 94 22% 33% 33% See Note 11 B9.12 0 0%/0 0% 0%/ See Note 6 and 11 B9.21 9 22% 22% 22%/ See Note 11 B9.31 6 17% 33% 33% See Note 11 B9.32 1 0% 0% 0%/ See Note 11 B9.40 23 22% 40% 40% See Note 11

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part J. page 2 of 4

1) Ownemi Interae Power and Light Company, Central Iowa Power Cooperative Con Bek Power Cooperative an Ailiant company Maion, LA Hunbot, A.

P.O. Bocx 3S1 Cedar Rapids, LA 52406

2) Plant Duane Arnold Energy Center, Pal, LA.52324 3) Plant Unit #1
4) Ownen Cettificate of Authorization (if required): N/A 5) Conrinercial Service Date: 02101fS
6) NationalBoardNunberofUnit: N/A GrosGencrating Capacity 614MWE STATUS OF WORK FOR THIRD TEN YEAR INTERVAL CLASS 1 ITEM NO. TOTAL # PERIOD I PERIOD 2 PERIOD 3 REMARKS B10.10 1 0°h 0% 0% See Note 4 B10.20 3 33% 67% 100% SeeNote4 B10.30 1 0% 0/O 100Y SeeNote4 B12.20 2 0% 0/. 0°/e B12.50 45 6% 9%S 11% SeeNote3 B13.10 35 37% 63% 77%

B13.20 11 36% 36% 72%

B13.30 27 4% 4% 44%

B13.40 5 20% 20% 80%

B14.10 3 0% 0% 0%

B15.10 I N/A N/A N/A Once per refueling outage B15.11 1 N/A N/A N/A Onceperinterval CLASS 1 AND CLASS 2 Risk Informed ITEM NO. TOTAL # PERIOD 1 PERIOD 2 PERIOD 3 REMARKS R-I 70 0% 33% 33% See Note 1 CLASS2 ITEM NO. TOTAL # PERIOD 1 PERIOD 2 PERIOD 3 REMARKS Cl.10 2 50°/. 50% 100°h Cl.20 1 0% 100% 100'/.

C2.21 2 0DA 50% 100%

C2.22 2 0°%. 50% 100%

C3.10 1 0°/. 0°/0 100% See Note 4 C3.20 7 29% 57/e 100% See Note 4 C5.51 69 17% 36% 36% SeeNote 11 C5.81 I 100' 100% 100% SeeNote l C7.10 5 N/A N/A N/A Once per period C7.20 5 N/A N/A N/A Once per interval

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20,2003 Part J page 3 of 4

1) Owners: Interstate Power and Light Company, Central Iowa Power Coopeative Con Belt Power Coaerative an Afliant company Marion, A. Humbot, LA.

P.O. Boax 351 Cedar Rapids, IA. 52406

2) Plant: Duane Amold Ener Center Palo, IA. 52324 3) PlantUnie 1
4) Owners Caitificate of Authorization (ifequie: NA 5) Cmmercial Service Date: 02101nS
6) National BoardNumberofUnit: N/A Gross GenerafingCapacity 614MWE STATUS OF WORK FOR THIRD TEN YEAR INTERVAL CLASS 1 AND 2 SUPPORTS ITEM NO. TOTAL # PERIOD I PERIOD 2 PERIOD 3 REMARKS F1.10 42 33% 64% 100% See Note 5 F1.20 52 27% 58% 100% See Note 5 Fl.40 20 40% 65% 85% See Note S STATUS OF WORK FOR (IWE) FIRST TEN YEAR INTERVAL CLASS MC ITEM NO. TOTAL # PERIOD 1 PERIOD 2 PERIOD 3 REMARKS Et.11 3 33% 67% 0/e El.12 31 19%h 67% 0/0 E1.20 8 38% 75% 0/.

E4.11 2 0%/. 40% 0%/. See Note 9 E5.30 4 25% 75% 0%/.

E8.10 .14 29% 71% 0%/0 E9.20 NIA N/A N/A See Note 10

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part I, page 4 of 4 I) Owners Interstate Power and Light Coman, Central Iowa Power Cooperatie Corn Belt Power Cooperative an Alliant company Marion, LA. Hurnbok LtA P.O. Box 351 Cedar Rapids. LA52406

2) Plant: Duane Arnold Enery Center, Palo, LA 52324 3) Plan Unit: #l
4) Owners Certificate of Authorization (if required): N/A 5) Commrcial Service Date: 02/OIfS
6) National Board Number ofUnit: N/A GrossGencratingCapacity 614MWE STATUS OF WORK FOR 1HIRD TEN YEAR INTERVAL NOTE - Item Numbers B3.90, B3.100 There are a total of 34 nozzles, however I of the nozzles is exempt by IWB-1220(c) and not included in the percentages.

NOTE 2 - Item Numbers B4.1 1, B4.12, B4.13 These items are required to be examined during conduct of the system hydrostatic test, ES Utilities has implemented Code Case N498-1 (TAP-P01 1)

NOTE 3 - Item Numbers B6.180, B6.190, B6.200, B7.50, B7.60, B7.70, B7.80, B12.50 These examinations are performed when the component is disassembled for other reasons. Therefore IWX-2412-1 does not apply.

NOTE 4- ItemNumbers B10.10, B10.20, B10.30, C3.10, C3.20 These item numbers are from Code Case N509 (TAP-1007)

NOTE 5 - Item Number Fl.10, F1.20, F1.40 These item numbers are from Code Case N491 (TAP-1008)

NOTE 6 - Item Number B9.12 There are no welds counted for this item number because of the use of Code Case N-524 (NDE-R012)

NOTE 7 - ItemNumberBl.30 50%/. of the shell-to-flange weld maybe performed during the first and third inspection periods as allowed by Note 4 of Table IWB-2500-1.

NOTE 8 - Item Numbers B3.90, B3.100, B5.10 Relief Request NDE-R035 allows alternative percentages (ref. Code Case N-598). 2 of the Nozzle-to-safeend welds (RRB-F002 and RRD-F002) have been repaired by applying a weld overlay. These two welds are now covered by the requirements of BWRVIP-75.

NOTE 9 - Item Number E4.11 The DAEC has evaluated the need for augmented examination per this item number and has determined that the Torus should be examined twice per interval. Details are specified in Technical Approach and Position TAP-E002.

NOTE 10 - Item Number E9.20 There are no components identified under this item number because the DAEC has been approved to use Option B of Appendix J. The 'Performance Based Containment Testing Program" contains the requirements.

NOTE I -Item Numbers B5.XX, B9.XX, C5XX, and R-I Risk-Informed methods are utilized as described in EPRI TR-1 12657B-A to determine scope of inspections for examination categories B-F, B-J, and C-F-2. The Risk-Informed scope has been combined into a new item number R-I for implementation in the second and third periods of the third interval.

TIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20, 2003 Part K, page I of I

1) Owners: Interstate Power and Ught Company, Central Iowa Power Cooperative Corn Bet Power Cooperative an Alliant company Marion, IA. Humbokt, LA P.O. Box 351 Cedar Rapids, IA. 52406
2) Plant Duane Arnold Energy Center, Palo, [A. 52324 3) Plant Unit: #1
4) Owners Certificate of Authorirtion (if required): N/A 5) Commercial Service Date 0201M 5
6) National Board Number of Unit N/A Gross Generating Capacity- 614 MWE RELIEF REQUESTS The following are the relief requests and code cases that were used during the period of this Summary Report RELIEF REOUESTS DESCRIPTION NDE-R01 I Use of Existing Calibration Blocks as an alternative NDE-R012 Alternative Examination of Class I and 2 piping longitudinal seam welds NDE-R014 Exemption from Appendix m calibration block notch dimensions NDE-R015 Rev. Use of the 1992 Addenda of ASME Section Xl to govern repairs/replacements NDE-R018 Alternative Rules for the selection and examination of Class 1, 2, and 3 integrally welded attachments NDE-R020 Use of the DAEC Technical Specification requirements for visual examination and functional testing of snubbers NDE-R027 Limited Exam of Closure Head Threads in Vessel Flange.

NDE-R035 Alternative Requirments to Required Percentages of Examinations NDE-R038 Alternative Requirements to VH-4240 "Annual Training" NDE-R041 Use of the 1992 Edition of ASME Section )a for "Additional Examinations" PR-002 Alternative Testing for Class2 Pressure Retaining Containent Penetrations connected to nonsafety related piping systems MC-R001 Qualification of Nondestructive Examination Personnel MC-R002 Alternative to VT-3 for Seals and Gaskets MC-R003 Alternative to Torque Test of Bolting MC-R004 Preservice Examination of Reapplied Paint or Coatings MC-RO05 Visual Examination of Painted or Coated Containment Components Prior to Removal of Paint of Coatings MC-R006 Successive examinations of Repaired Areas CODE CASE # DESCRIPTION N-198-1 (NDER023) hnaccessible welds located in Containment Penetrations N-416-1 (PR-004) Alternative pressure testing requirements for welded repairs or installation or replacement items by welding, Class 1, 2, and 3.

N-491 (AP-4008) Alternative rules for examination of Class 1,2,3 and MC component supports N-508-1 (NDE-R033) Rotation of Serviced Snubbers and Pressure Relief Valves for the Purpose of Testing N-509 (TAP-1007) Alternative rules for selection and examination of Class 1, 2,3 and integrally welded attachments N-516-1 (NDE-R042) Underwater Welding N-546 (PR-008) Alternative requirements for Qualification of VT-2 Examination Personnel N-598 (NDE-R035) Alternative Requirements to Required Percentages of Examinations N-606 (MC-R007) Extent and Frequency of VT-3 for Items E1.12 and E1.20

THIRD TEN YEAR INTERVAL INSERVICE INSPECTION REPORT March 31, 2003 through April 20,2003 This page intentionally blank

Attachment 3 to NG-03-0509 Augmented Inspection Results RFO 18 (3 Pages)

AUGMENTED INSPECTION RESULTS RFO18 System Description Weld or Component Report Inspection ISI Isol Fig Acc Examination Description Number Requirement Number REACTOR WATER CUB-J005 103024 A 1.2-1 IB Y UT CLEANUP CUB-JO08 103025 A 1.2-1 B Y UT CUB-JO1 103026 A 1.2-1 IB Y UT CUB-JO1 103027 A 1.2-1 IB Y UT CUB-J013 I03028 A 1.2-1 IB Y UT CUB-J014 103029 A 1.2-1 B Y UT CUB-J016 103030 A 1.2-1 IB Y UT CUB-J017 103031 A 1.2-1 B Y UT CONTROL ROD DRIVE CRA-F002 103008 C 1.2-12A Y UT CRA-F004 103009 C 1.2-12A Y UT CRA-J003 103015 C 1.2-12A Y UT RCIC RSB -J008 103035 A 1.2-18 Y UT RSB -009 103036 A 1.2-18 Y UT RECIRCULATION PUMP RCA-JOO5B 103037 A 1.2-19A Y UT SUCTION RCA-J018 103038 A 1.2-19A Y UT RECIRCULATION RBB-J006 103046 A 1.2-21A Y UT SYSTEM PUMPNALVE RBB-J007 103047 A 1.2-21A Y UT BYPASS RBB-J008 103048 A 1.2-21A Y UT RBB-J012 103049 A 1.2-21A Y UT Recirculation Pump RCB-J021 103051 A 1.2-21A Y UT Suction RCB-J037 103052 A 1.2-21A Y UT Steam Dryer Assembly STEAM DRY EXT SURFACE 103064 B VS-7-1 Y VT-3 FEEDWATER SPARGER 450 & 1350 103064 F VS-09-01 Y EVT-1 JET PUMPS JET PUMP #05 103064 G VS-11-01 Y EVT-1 JET PUMP #06 103064 G VS-11-01 Y EVT-1 JET PUMP #07 103064 G VS-11-01 Y EVT-1 JET PUMP #08 103064 G VS-11-01 Y EVT-1 JET PUMP #09 103064 G VS-11-01 Y EVT-1 JET PUMP #10 103064 G VS-11-01 Y EVT-1 JET PUMP #11 103064 G VS-11-01 Y EVT-1 JET PUMP #12 103064 G VS-11-01 Y EVT-1 ACC- ACCEPTED, Y INDICATING ACCEPTED, N INDICATING REJECTED.

A- BWRVIP-75 E - BWRVIP-76 (GL 94-03)

B- GE SILS F-BWRVIP-I8 C -NUREG 0619 G - BWRVIP.41 D- BWRVIP H - OWNER DEFINED

AUGMENTED INSPECTION RESULTS RFOIS System Description Weld or Component Report Inspection ISI Iso/ Fig Acc Examination Description Number Requirement Number Core Spray HEADERS 103064 F VS-05-01 Y EVT-1 DOWNCOMERS I03064 F VS-05-01 Y EVT-1 JET PUMPS JET PUMP #01 BEAM BOLT I03064 G VS-11-01 Y EVT-I JET PUMP #02 BEAM BOLT I03064 G VS-1 1-01 Y EVT-I JETPUMP#03BEAMBOLT 103064 G VS-11-01 Y EVT-I JET PUMP #04 BEAM BOLT I03064 G VS-11-01 Y EVT-I JET PUMP #05 BEAM BOLT 103064 G VS-11-01 Y EVT-I JET PUMP #06 BEAM BOLT 103064 G VS-1 1-01 Y EVT-1 JET PUMP #07 BEAM BOLT 103064 G VS-11-01 Y EVT-I JET PUMP #08 BEAM BOLT I03064 G VS-11-01 Y EVT-1 JET PUMP #09 BEAM BOLT I03064 G VS-11-01 Y EVT-1 JET PUMP #10 BEAM BOLT I03064 G VS-11-01 Y EVT-1 JET PUMP #11 BEAM BOLT 103064 G VS-1 1-01 Y EVT-1 JET PUMP #12 BEAM BOLT 103064 G VS-1 1-01 Y EVT-I JET PUMP #13 BEAM BOLT I03064 G VS-1 1-01 Y EVT-I JET PUMP #14 BEAM BOLT 103064 G VS-1 1-01 Y EVT-I JET PUMP #15 BEAM BOLT 103064 G VS-11-01 Y EVT-I JET PUMP #16 BEAM BOLT I03064 G VS-11-01 Y EVT-1 CRD CRD GUIDE TUBES 103064 D VS-13-02 Y EVT-1 ACC- ACCEPTED, Y INDICATING ACCEPTED, N INDICATING REJECTED.

A- BWRVIP-75 E - BWRVIP-76 (GL 94-03)

B- GE SILS F - BWRVIP-I 8 C-NUREG 0619 G - BWRVIP-41 D- BWRVIP H - OWNER DEFINED

AUGMENTED INSPECTION RESULTS RFO18 System Description Weld or Component Report Inspection ISI Iso/ Acc Examination Description Number Requirement Fig Number Core Spray CSA-J003 103017 A 1.2-07 Y UT ACC- ACCEPTED, Y INDICATING ACCEPTED, N INDICATING REJECTED.

A- BWRVIP-75 E - BWRVIP-76 (GL 94-03)

B- GE SILS F - BWRVIP-18 C - NUREG 0619 G - BWRVIP41 D-BWRVIP H - OWNER DEFINED