Southern Nuclear

~ Southern Nuclear Operating Company, Inc.

3535 Colonnade Parkway Birmingham. AL 35243 Tel 205.992.6361 June 3, 2020 Docket Nos.: 52-025 ND-20-0645 52-026 10 CFR 50.55a U.S. Nuclear Regulatory Commission ATTN : Document Control Desk Washington , DC 20555-0001 Southern Nuclear Operating Company Vogtle Electric Generating Plant Units 3 and 4 Submittal of Preservice Test Plan - Version 3.0 Ladies and Gentlemen:

In accordance with the applicable American Society of Mechanical Engineers Code for Operation and Maintenance of Nuclear Power Plants (ASME OM Code), Subparagraph ISTA-3200, and Southern Nuclear Operating Company (SNC) procedures, SNC is submitting , for your information, a copy of the Vogtle Electric Generating Plant Units 3 and 4 Preservice Test Plan Version 3.0. This version adds previously approved PST-Alt-02 (ML19130A218) for pressurizer relief valve testing ,

adds a thermal relief function for several valves consistent with recently submitted lnservice Test Program (ML20142A358), removes a closed safety function for RCS-PL-V001A/B, revises to reflect a fai l-safe test for RNS-PL-V061 , and includes revised references, and various editorial and grammatical revisions.

This letter contains no regulatory commitments. This letter has been reviewed and confirmed to contain no security-related information.

Should you have any questions, please contact Ms. Amy Chamberlain at (205) 992-6361 .

Respectfully submitted ,

Amy C. Chamberlain Manager, Regulatory Affairs Southern Nuclear Operating Company : Vogtle Electric Generating Plant Units 3&4, Preservice Test Plan Version 3.0

U.S. Nuclear Regulatory Commission ND-20-0645 Page 2 of 3 cc:

Southern Nuclear Operating Company / Georgia Power Company Mr. S. E. Kuczynski (w/o enclosures)

Mr. P. P. Sena III (w/o enclosures)

Mr. M. D. Meier (w/o enclosures)

Mr. G. Chick Mr. M. Page Mr. P. Martino Mr. D. L. McKinney (w/o enclosures)

Mr. T. W. Yelverton (w/o enclosures)

Mr. B. H. Whitley Ms. C. A. Gayheart Ms. M. Ronnlund Mr. D. L. Fulton Mr. M. J. Yox Mr. C. T. Defnall Mr. J. Tupik Ms. S. Agee Mr. M. Humphrey Ms. A. C. Chamberlain Mr. S. Leighty Mr. N. Kellenberger Mr. E. Riffle Ms. K. Roberts Mr. J. Haswell Mr. D. T. Blythe Mr. K. Warren Mr. A. S. Parton Document Services RTYPE: VND.LI.L00 File AR.01.02.06 Nuclear Regulatory Commission Mr. W. Jones (w/o enclosures)

Mr. M. King (w/o enclosures)

Ms. M. Bailey w/o enclosures)

Mr. C. Patel Mr. C. Santos Mr. B. Kemker Mr. J. Eargle Mr. G. Khouri Ms. S. Temple Mr. C. J. Even Mr. A. Lerch Mr. S. Walker Mr. N.D. Karlovich Ms. N. C. Coovert

U.S. Nuclear Regulatory Commission ND-20-0645 Page 3 of 3 Nuclear Regulatory Commission (Continued)

Mr. C. Welch Mr. J. Gaslevic Mr. V. Hall Ms. K. P. Carrington Mr. M. Webb Mr. P.J. Heher State of Georgia Mr. R. Dunn Oglethorpe Power Corporation Mr. M. W. Price Ms. A. Whaley Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Dalton Utilities Mr. T. Bundros Westinghouse Electric Company, LLC Mr. L. Oriani (w/o enclosures)

Mr. T. Rubenstein (w/o enclosures)

Mr. M. Corletti Mr. D. Hawkins Mr. J. Coward Other Mr. S. W. Kline, Bechtel Power Corporation Ms. L. A. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GDS Associates, Inc.

Mr. S. Roetger, Georgia Public Service Commission Ms. S. W. Kernizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. S. Blanton, Balch Bingham

Southern Nuclear Operating Company ND-20-0645 Enclosure 1 Vogtle Electric Generating Plant Units 3 and 4 Preservice Test Plan Version 3.0 (dated May 12, 2020)

(This enclosure consists of 127 pages, not including this cover page.)

PRESERVICE TEST PLAN Vogtle Electric Generating Plant Units 3&4 Docket Nos. 52025 & 52026 License Nos. NPF91 & 92 May 12, 2020 Commercial Operation dates: TBD (Unit 3)

TBD (Unit 4)

Owner: Southern Nuclear Operating Company Inc.

Post Office Box 1295 Birmingham, AL 352011295 Plant Location: 7825 River Road Waynesboro, GA 30830 1

Southern Nuclear Version 3.0

TABLE OF CONTENTS Section Pages 1.0 PST PROGRAM INTRODUCTION 34 2.0 ABBREVIATIONS 57 3.0 PROGRAM ALTERNATIVES 8 14 4.0 PRESERVICE TESTING OF PUMPS 15 5.0 PRESERVICE TESTING OF VALVES 16 6.0 VALVE NOTES 17 7.0 VEGP3 VALVE TABLES 18 61 8.0 VEGP4 VALVE TABLES 62 105 9.0 PRESERVICE TESTING OF DYNAMIC RESTRAINTS 106 10.0 DYNAMIC RESTRAINTS NOTES 107 11.0 VEGP3 DYNAMIC RESTRAINTS TABLES 108 115 12.0 VEGP4 DYNAMIC RESTRAINTS TABLES 116 123 13.0 REFERENCE LIST 124 127 2

Southern Nuclear Version 3.0

1.0 PST PROGRAM INTRODUCTION 1.1 GENERAL This document describes the Pump, Valve, and Dynamic Restraint Preservice Testing (PST) Plan for the Vogtle Electric Generating Plant (VEGP), Units 3 & 4. Provided below are important dates relative to the PST Plan.

Combined Operating License: February 10, 2012 (Unit 3); February 10, 2012 (Unit 4)

Estimated Commercial Operation: November 2021 (Unit 3); November 2022 (Unit 4) 1.2 CODE EDITION This PST Plan is based on the American Society of Mechanical Engineers (ASME) Operation and Maintenance of Nuclear Power Plants (OM) Code 2012 Edition, which was approved for use in 10 CFR 50.55a effective August 17, 2017.

1.3 EFFECTIVE DATE The PST plan will begin on the date of the submittal of this plan and conclude with the initial electrical generation by nuclear heat on each unit, unless federal regulations are revised otherwise.

1.4 SCOPE This document is a description of the PST Plan for Units 3 and 4 at VEGP. This document describes only the PST required by the OM Code for applicable components required to be tested by the OM Code, 10CFR50.55a, and additional components committed to be included in the PST plan in the Updated Final Safety Analysis Report (UFSAR).

To ensure that components that meet the Scope requirements of the OM Code, but may not be required to be constructed to ASME B&PV Code Class 1, 2 or 3, are adequately tested for operational readiness as required by 10CFR50.55a(f)(4), this PST plan includes all Safety Related (AP1000 Quality group A, B, C) pumps, valves and dynamic restraints that meet the Scope of ISTA1100, and ISTF1100.

1.5 SUBSEQUENT PLAN REVISIONS It is anticipated that revisions to this document required by changes to the design during the Preservice Test Period will be maintained on site. Any changes which require NRC approval of Alternative testing requirements will be submitted in accordance with 10CFR50.55(a)(z).

1.6 RESPONSIBILITY Southern Nuclear Operating Company (SNC) bears the overall responsibility for the implementation of the Preservice testing activities contained in this program per the ASME OM Code, Subsection ISTA1500.

3 Southern Nuclear Version 3.0

1.7 RECORDS Records and documentation of information and testing results, which provided the basis for evaluation and which facilitate comparison with results from previous and subsequent tests, will be maintained and available for the active life of the component or system in accordance with the ASME OM Code, Subsection ISTA9000.

4 Southern Nuclear Version 3.0

2.0 ABBREVIATIONS ABBREVIATION DEFINITION A Active (valve table)

A OM Code Category A Valve AC OM Code Categories A and C both apply ADS Automatic Depressurization System AI AsIs Alt Alternative per 10CFR50.55a(z)

AO Air Operated A/P Active/Passive (valve table)

App Appendix App. J Leak rate testing to 10CFR50 Appendix J requirements (CIV)

ASME American Society of Mechanical Engineers ASME OM Code ASME Operation and Maintenance of Nuclear Power Plants Code Aug Augmented scope (not required by ASME OM Code)

B OM Code Category B Valve BA Ball Valve BU Butterfly Valve C OM Code Category C Valve C Close/Closed CAS Compressed Air System Cat Category CC Code Case CCS Component Cooling Water System CFR Code of Federal Regulations CK Check Valve CIV Containment Isolation Valve CKC Check Valve Closed CKO Check Valve Open CKOP Check Valve Partial Opening CMT Core Makeup Tank CoOrd. Coordinate CVS Chemical and Volume Control System CV Check Valve D OM Code Category D Valve DVI Direct Vessel Injection DWS Demineralized Water System 5

Southern Nuclear Version 3.0

EH ElectroHydraulic Operated ETM Exercise Test Manual Valve (Full stroke)

FHS Fuel Handling System FPS Fire Protection System FST FailSafe Test GA Gate Valve GL Globe Valve H Hydraulic Snubber IRC Inside Reactor Containment building IRWST InContainment Refueling Water Storage Tank LC Locked Closed LO Locked Open LT Leak Test MA Manual Operator MO Motor Operated MSS Main Steam System MTS Main Turbine System N No NA Not Applicable O Open ORC Outside Reactor Containment building P Passive (valve basis table)

PCS Passive Containment Cooling System PH Pneumatic/Hydraulic PI Remote Position Indication Verification PIV Pressure Isolation Valve (see UFSAR Table 3.918)

PORV Power Operated Relief Valve PL Plug Valve PSS Primary Sampling System PWS Potable Water System PXS Passive Core Cooling System 6

Southern Nuclear Version 3.0 I

RCS Reactor Coolant System RD Rupture Disc RNS Normal Residual Heat Removal System RRD Replace Rupture Disc RV Relief Valve RVT Relief Valve Test SA SelfActuating SC Stop Check valve SDS Sanitary Drainage System SFS Spent Fuel Pool Cooling System SGS Steam Generation System SO Solenoid Operated SQ Squib (explosively actuated) Valve STC Stroke Time Closed test STO Stroke Time Open test VB Vacuum Breaker VBS Nuclear Island NonRadioactive Ventilation System VE Visual Examination VES Main Control Room Emergency Habitability System VFS Containment Air Filtration System VWS Central Chilled Water System WLS Liquid Radioactive Waste System Y Yes III3100 MOV capability verification per ASME OM Code App. III3100 III3300 MOV Preservice test per ASME OM Code App. III3300 7

Southern Nuclear Version 3.0 I

3.0 PROGRAM ALTERNATIVES 3.1 ALTERNATIVES This section identifies the Alternatives to the requirements of 10CFR50.55a and the OM Code requested under 10 CFR 50.55a(z) and approved by the NRC.

Alternative VEGP 3&4PSTAlt01 to the PST plan, regarding charge testing of explosively actuated valves was authorized by the NRC on 3/26/2019, and is attached.

Alternative VEGP 3&4PSTAlt02 to the PST plan, regarding testing of Class 1 safety valves before initial electric power generation, was authorized by the NRC on 5/28/2019, and is attached.

3.2 CODE CASES This section identifies the Code Cases, and associated limitations, that are incorporated in this PST plan.

No Code Cases are currently used in this PST plan.

8 Southern Nuclear Version 3.0

Alternative VEGP3&4PSTAlt01 Vogtle Electric Generating Plant (VEGP) - Units 3 and 4 Plant Site-Unit:

IntervalInterval Applies to the preservice testing period.

Dates:

Approval Date: March 26, 2019.

ASME Code Components ASME Class 1 and 3 Explosively Actuated Valves.

Affected:

Applicable Code Edition and ASME OM Code, 2012 Edition (Code of Record).

Addenda:

ASME OM Code, ISTC3100(d)(2) requires that for post2000 plants, Category D explosively actuated valves shall be preservice tested as follows:

Select a sample of at least 20% of the pyrotechnic charges in all valves to be Applicable Code tested. Test each selected charge either in the valve, or a qualified test fixture Requirements: to confirm the capability of each sampled charge to provide the necessary motive force to operate the valve to perform its intended function without damage to the valve body or connected piping. The sampling must include at least one explosively actuated valve from each redundant safety train.

Based on the ASME OM Code definition of preservice test, which states test performed after completion of construction activities related to the Reason for component, and the statement in ISTC3100(d)(2) that Pyrotechnic Request: charges in all valves, it is implied that the charges must be installed in the valves, and the valves be installed in the system, prior to selection of the charges for testing. Handling of explosive charges exposes personnel to significant risks. Since the charges are fabricated and shipped separately, and the testing will be done by the vendor or another offsite test facility, the current requirements would involve shipping of the charges to the site, installation of the charges in the valves (which would be installed in the 9

Southern Nuclear Version 3.0

piping, in containment), removal of the charges, and shipment of the charges back to the vendor or other test facility.

To minimize handling and transportation of explosive charges, it is proposed to select the charges after fabrication and retain for testing at the vendor, or in the worst case, ship them from the vendor to a separate facility for testing.

Proposed Alternative:

In lieu of the requirements of ISTC3100(d)(2), perform the following:

Select a sample of pyrotechnic charges, following fabrication for testing; this may include charges used for qualification of the batch. The sample shall include a quantity of charges equal to at least 20% of the number of charges of each size installed in the plant and shall include at least one from each manufacturer batch. A description of SNCs planned testing relative to the Code requirements is shown in Table 1 below. Each selected charge shall be tested in a qualified test fixture to confirm the capability of each sampled charge to provide the necessary motive force to operate the valve to perform its intended function without damage to the valve body or connected piping.

Proposed Basis for Use:

Alternative and The proposed alternative provides an equivalent level of safety as it ensures Basis for Use: the charges are tested to the same criteria, and that the charges are tested from each batch (manufacturer, lot and size). The allowance of crediting the qualification samples is equivalent to or better than ISTC5260(d), which only requires test firing of one charge per batch prior to installation as a replacement charge.

The requirement regarding inclusion of one test sample from each train is not applicable, because the charges are selected for testing prior to installation in the valve. However, the selection of charges for installation in valves of each train is random; therefore, the level of testing is equivalent.

The proposed alternative provides improved personnel safety by minimizing the transportation and handling of explosive charges.

Because the proposed alternative tests an equivalent number of pyrotechnic charges to the same criteria, this proposed alternative provides an acceptable level of quality and safety in accordance with 10 CFR 50.55a(z)(1).

10 Southern Nuclear Version 3.0

Duration of Proposed Preservice testing conducted prior to commercial operation.

Alternative:

References:

None.

Table 1: Vogtle 3&4 Planned Explosively Actuated Valve Charge Testing per Purchase Specification Number in plants (number per unit IST Number to Number Batch Charge size x units) (20%) IST (1/train) be Tested Fabricated A 14 valves 8 (4 x 2) 2 4 8 16 B 8 valves - 12 (6 x 2) 3 6 8 20 high C 8 valves - 4 (2 x 2) 1 2 8 12 low Notes:

1. Each charge size is a single batch
2. There are two sizes of charges for the 8 explosively actuated valves, high energy and low energy 11 Southern Nuclear Version 3.0

Alternative VEGP3&4PSTAlt02 Plant SiteUnit: Vogtle Electric Generating Plant (VEGP) - Units 3 and 4 IntervalInterval Applies to the preservice testing period.

Dates:

Date Authorized: May 28, 2019 ASME Code Components ASME Class 1 Safety Valves.

Affected:

Applicable Code Edition and ASME OM Code, 2012 Edition (code of record).

Addenda:

ASME OM Code, I7210 requires Class 1 safety valve testing. Within 6 months before initial reactor criticality, each valve shall have its setpressure verified.

Applicable Code Setpressure verification shall be determined by pressurizing the system up to Requirements:

the valve setpressure and opening the valve, or the valve may be tested at or below normal system operating pressures with an assist device.

The existing Code requirement implies that the safety valves be tested in place. The valves are located on top of the pressurizer. Due to the temperature environment of this location, testing of the safety valves Reason for Request: presents a personnel safety issue to personnel performing the testing as it involves activities such as use of an assist device and installation of a gag on the valve not being tested.

Also, the timing requirement of within 6 months before initial criticality provides potential scheduling issues. If the 6 months expires just before initial criticality, the plant would be in a hot, pressurized condition and would have to be cooled down and depressurized to replace the valves. Tying testing to the fuel load milestone is favorable since, for potential delays that 12 Southern Nuclear Version 3.0

push the fuel load date outside of the proposed 3 month test requirement, the plant would be in a cold and depressurized condition, and the valves could be removed and replaced without having to put a thermal cycle on the plant with the associated time delays of cooling down/depressurizing and subsequent return to normal operating temperature and pressure.

Per discussions with the Appendix I SubGroup, the purpose of this requirement is to ensure that the plant is started up with safety valves with recently verified setpoints and to ensure that valves do not go an excessive time prior to retesting if initial startup is prolonged. Additionally, they believe that I7210 was not meant to preclude the use of pretested valves. The use of pretested valves is allowed per I1320 in lieu of in place testing for routine inservice testing.

Proposed Alternative:

In lieu of performing setpoint testing with the valve installed in the system within 6 months before initial criticality in accordance with I7210, Class 1 Safety Valves shall be replaced with Pretested valves. The setpressure test of the valves shall not be more than 3 months prior to the commencement of Initial Fuel loading. The initial testing per I1320, shall be no longer than 24 months from the date of the setpressure verification test.

Basis for Use:

The Class 1 safety relief valves are Crosby, model number HBBP86. This Proposed manufacturer and model have been commonly used in the nuclear industry in Alternative and this application and have a history of acceptable performance with regards to Basis for Use: setpoint drift.

The proposed alternative provides an equivalent level of safety as it ensures that the safety valves setpoints will be verified recently prior to beginning of fuel loading and subsequent initial startup activities, and that inservice valve testing is not extended past the normal frequency, even if the startup process prior to Initial Generation of Electricity by nuclear heat is prolonged. This alternative provides the additional benefit of improving personnel safety by not having personnel in a heat stress environment to perform inplace testing.

If the schedule of startup activities begins to challenge a testing frequency of 24 months following the preservice test, SNC will evaluate additional setpoint testing prior to startup or performance of a midcycle shutdown to ensure inservice testing is performed at the required inservice testing interval. A 13 Southern Nuclear Version 3.0

review was performed of Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) 2.1.02.08a.ii for testing and analysis of safety relief valves in accordance with ASME Section III. This proposed Code alternative does not have any impact on the ITAAC.

Since the proposed alternative is consistent with inservice testing requirements for replacing with pretested valves in accordance with I1320(b) and the frequency of the first inservice test limits the amount of time between setpressure verification tests, this proposed alternative provides an acceptable level of quality and safety in accordance with 10 CFR 50.55a(z)(1).

Duration of Proposed Preservice testing conducted prior to commercial operation.

Alternative:

References:

None.

14 Southern Nuclear Version 3.0

4.0 PRESERVICE TESTING OF PUMPS 4.1 GENERAL There are no pumps in the AP1000 design that meet the scoping criteria of ISTF1100. ISTF 1000 which provides the scoping criteria for pumps to be included in the PST plan, includes only pumps that have an emergency power source. The emergency power source (Class 1E) for the AP1000 is the 1E Vital DC system, and there are no pumps powered from this source.

15 Southern Nuclear Version 3.0

5.0 PRESERVICE TESTING OF VALVES 5.1 GENERAL Valves will be tested to meet the PST requirements of the OM Code as outlined in the Valve Tables.

The OM Code identifies exercise testing for valves, where the Code requires additional testing be performed during the valve exercising (e.g. stroke time testing), the exercise test is not separately identified in the Valve Table.

Testing will generally only be performed once during the Preservice Test Period, except when Repair, Replacement, or Maintenance require retesting pursuant to ASME OM ISTC 3100(a)/ISTC3310/I7400/III3400.

5.2 ADDITIONAL TESTING REQUIREMENTS 10CFR50.55(a) provides conditions to the OM Code with regard to testing of certain valves.

These conditions are met in this PST Plan as outlined below:

5.2.1 To meet the 10CFR50.55a(b)(3)(ii)(D) Condition on MOV stroke time. A stroke time test to the safety position(s) is specified for MOVs in the program.

5.2.2 To meet the 10CFR50.55a(b)(3)(iii)(B) Check valves requiring Licensees must perform bidirectional testing of check valves, is specified in accordance with ISTC5221 within this PST plan, where practicable.

5.3 SCHEDULE PST will be performed following system turnover from Construction, and will be completed prior to initial electrical generation by nuclear heat.

16 Southern Nuclear Version 3.0

6.0 VALVE NOTES None 17 Southern Nuclear Version 3.0

7.0 VEGP3 VALVE TABLES 18 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: CAS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3CASPLV014 2 N A A 2 BA AO SV3CASM6005 O C C PI (ISTC3700)

(F3) STC FST Instrument Air Containment Isolation Valve LTApp. J SV3CASPLV015 2 N AC A 2 CK SA SV3CASM6005 O C/O NA CKC (F4) CKOP Accommodate thermal expansion Instrument Air Containment Isolation Check Valve LTApp. J SV3CASPLV204 2 N A P 3 BA MA SV3CASM6012 LC C C LTApp. J Service Air Containment Isolation Valve (E5)

SV3CASPLV205 2 N AC A 3 CK SA SV3CASM6012 C C/O NA CKC (E4) CKOP Accommodate thermal expansion Service Air Containment Isolation Check Valve LTApp. J 19 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: CCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3CCSPLV200 2 N A A 10 BU MO SV3CCSM6002 O C AI PI (III3300)

(H2) STC III3100 III3300 Cooling Water Supply Ctmt Isol ORC LTApp. J SV3CCSPLV201 2 N AC A 10 CK SA SV3CCSM6002 O C/O NA CKC (H2) CKOP Accommodate thermal expansion Cooling Water Ctmt Supply Check LTApp. J SV3CCSPLV207 2 N A A 10 BU MO SV3CCSM6002 O C AI PI (III3300)

(B2) STC III3100 III3300 Cooling Water Return Ctmt Isol - IRC LTApp. J SV3CCSPLV208 2 N A A 10 BU MO SV3CCSM6002 O C AI PI (III3300)

(B1) STC III3100 III3300 Cooling Water Return Ctmt Isol ORC LTApp. J SV3CCSPLV220 2 N AC A 1 RV SA SV3CCSM6002 C C/O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (C2) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Ctmt Return CIV Thermal Relief LTApp. J SV3CCSPLV270 3 N C A 4 RV SA SV3CCSM6002 C O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (H2) RVT(I7150(c)) Leak tightness per Vendor test CCS Supply Line to Ctmt Safety/Relief VE(I7150(a))

SV3CCSPLV271 3 N C A 4 RV SA SV3CCSM6002 C O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (C2) RVT(I7150(c)) Leak tightness per Vendor test CCS Return Line to Ctmt Safety/Relief VE(I7150(a))

20 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: CVS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3CVSPLV001 1 N B A 3 GA MO SV3CVSM6001 O C AI PI (III3300)

(G8) STC III3100 CVS Purification Stop Valve III3300 SV3CVSPLV002 1 N B A 3 GA MO SV3CVSM6001 O C AI PI (III3300)

(G7) STC III3100 CVS Purification Stop Valve III3300 SV3CVSPLV003 3 N B A 3 GL MO SV3CVSM6001 O C AI PI (III3300)

(G7) STC III3100 CVS Purification Stop Valve III3300 SV3CVSPLV040 2 N A P 2 BA MA SV3CVSM6005 LC C AI LTApp. J Resin Flush Inside Containment Isolation Valve (F4)

SV3CVSPLV041 2 N A P 2 BA MA SV3CVSM6005 LC C AI LTApp. J Resin Flush Outside Containment Isolation Valve (F2)

SV3CVSPLV042 2 N AC A 1 RV SA SV3CVSM6005 C C/O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (G4) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Flush Line Containment Isolation Relief Valve LTApp. J SV3CVSPLV045 2 N A A 2 GL AO SV3CVSM6005 C C C PI (ISTC3700)

(D4) STC FST Letdown Line Inside Containment Isolation Valve LTApp. J SV3CVSPLV047 2 N A A 2 GL AO SV3CVSM6005 C C C PI (ISTC3700)

(D2) STC FST Letdown Line Outside Containment Isolation Valve LTApp. J 21 Southern Nuclear Version 3.0

System: CVS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3CVSPLV058 2 N AC A 1 RV SA SV3CVSM6005 C C/O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (E4) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Letdown Line Relief Thermal Relief Valve LTApp. J SV3CVSPLV064 N N C A 3 CK SA SV3CVSM6005 C O NA CKC Makeup Discharge Header Check Valve (C5) CKOP Accommodate thermal expansion SV3CVSPLV067 1 N C A 1 CK SA SV3CVSM6001 O C/O NA CKC Makeup Return Line SpringAssisted Check Valve (F7) CKOP Accommodate thermal expansion SV3CVSPLV080 3 N C A 3 CK SA SV3CVSM6001 O C/O NA CKC Regen HX Shell Side Outlet Check Valve (G7) CKOP Accommodate thermal expansion SV3CVSPLV081 1 N BC A 3 SC AO SV3CVSM6001 O C NA PI (ISTC3700)

(G7) CKC Purification Return Line Stop Check Valve CKOP SV3CVSPLV082 1 N C A 3 CK SA SV3CVSM6001 O C/O NA CKC RCS Purification Return Line Check Valve (G8) CKOP Accommodate thermal expansion SV3CVSPLV084 1 N B A 2 GL AO SV3CVSM6001 C C C PI (ISTC3700)

(F7) STC Auxiliary Pressurizer Spray Line Isolation Valve FST SV3CVSPLV085 1 N C A 2 CK SA SV3CVSM6001 C C/O NA CKC Auxiliary Pressurizer Spray Line Valve (F8) CKOP Accommodate thermal expansion SV3CVSPLV090 2 N A A 3 GA MO SV3CVSM6005 O C AI PI (III3300)

(C2) STC III3100 III3300 Makeup Line Outside Containment Isolation Valve LTApp. J SV3CVSPLV091 2 N A A 3 GA MO SV3CVSM6005 O C AI PI (III3300)

(C4) STC III3100 III3300 Makeup Line Inside Containment Isolation Valve LTApp. J SV3CVSPLV092 2 N A A 1 GL AO SV3CVSM6003 O C C PI (ISTC3700)

(F6) STC FST Zinc Injection Containment Isolation Valve ORC LTApp. J 22 Southern Nuclear Version 3.0

System: CVS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3CVSPLV094 2 N A A 1 GL AO SV3CVSM6003 O C C PI (ISTC3700)

(F7) STC FST Zinc Injection Containment Isolation Valve IRC LTApp.

SV3CVSPLV098 2 N AC A 1 RV SA SV3CVSM6003 C C/O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (F6) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Zinc Injection Ctmt Isol Thermal Relief Valve LTApp. J SV3CVSPLV100 2 N AC A 1 CK SA SV3CVSM6005 O C/O NA CKC (B4) CKOP Accommodate thermal expansion Makeup Line Containment Isolation Relief LTApp. J SV3CVSPLV136A 3 N B A 2 BU AO SV3CVSM6004 C C C PI (ISTC3700)

(C4) STC Demineralized Water System Isolation Valve FST SV3CVSPLV136B 3 N B A 2 BU AO SV3CVSM6004 C C C PI (ISTC3700)

(C4) STC Demineralized Water System Isolation Valve FST SV3CVSPLV217 2 N AC A 1/2 CK SA SV3CVSM6003 O C/O NA CKC (D7) CKOP Accommodate thermal expansion Hydrogen Injection Containment Isolation Check Valve IRC LTApp. J SV3CVSPLV219 2 N A A 1/2 GL AO SV3CVSM6003 O C C PI (ISTC3700)

(D6) STC FST Hydrogen Injection Containment Isolation Valve ORC LTApp. J 23 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: DWS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3DWSPLV241 3 N C A 1 RV SA SV3DWSM6007 C O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (E5) RVT(I7150(c)) Leak tightness per Vendor test Demin Water Supply to Containment Relief VE(I7150(a))

SV3DWSPLV244 2 N A P 3 BU MA SV3DWSM6007 LC C AI LTApp. J Exercised during Shutdown and leaktest Demin Water Supply Containment Isolation Outside (E6)

SV3DWSPLV245 2 N AC A 2 CK SA SV3DWSM6007 C C/O NA CKC (E6) CKOP Accommodate thermal expansion Demin Water Supply Containment Isolation Check Valve IRC LTApp. J 24 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: FHS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3FHSPLV001 3 N B A 30 GA MA SV3SFSM6001 C C AI ETM Fuel Transfer Tube Isolation Valve (F6) 25 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: FPS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3FPSPLV050 2 N A P 6 BU MA SV3FPSM6004 LC C AI LTApp. J Exercised during Shutdown and leaktest Fire Water Containment Supply Isolation (F5)

SV3FPSPLV052 2 N AC A 6 CK SA SV3FPSM6004 C C/O NA CKC (F5) CKOP Accommodate thermal expansion Fire Water Supply Cont Isol Check Valve IRC LTApp. J SV3FPSPLV702 3 N C A 1 RV SA SV3FPSM6004 C O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (F/G5) RVT(I7150(c)) Leak tightness per Vendor test Fire Water Supply IC Thermal Relief VE(I7150(a))

26 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: MSS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3MSSPLV001 N Y B A 16 GL AO SV3MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H8) STC Turbine Bypass Control Valve FST SV3MSSPLV002 N Y B A 16 GL AO SV3MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H7) STC Turbine Bypass Control Valve FST SV3MSSPLV003 N Y B A 16 GL AO SV3MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H6) STC Turbine Bypass Control Valve FST SV3MSSPLV004 N Y B A 16 GL AO SV3MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H4) STC Turbine Bypass Control Valve FST SV3MSSPLV005 N Y B A 16 GL AO SV3MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H3) STC Turbine Bypass Control Valve FST SV3MSSPLV006 N Y B A 16 GL AO SV3MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H2) STC Turbine Bypass Control Valve FST SV3MSSPLV015A N Y B A 10 GL AO SV3MSSM6001 O C C PI (ISTC3700) Required by TS 3.7.2 (B6) STC MSR 2ND Stage Reheat Steam AO Isolation Valve FST SV3MSSPLV015B N Y B A 10 GL AO SV3MSSM6001 O C C PI (ISTC3700) Required by TS 3.7.2 (G6) STC ND MSR 2 Stage Reheat Steam AO Isolation Valve FST 27 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: MTS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3MTSPLV001A N Y B A 28 GL EH SV3MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (F6) STC Main Turbine Stop Valve FST SV3MTSPLV001B N Y B A 28 GL EH SV3MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (C6) STC Main Turbine Stop Valve FST SV3MTSPLV002A N Y B A 28 GL EH SV3MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (F6) STC Main Turbine Control Valve FST SV3MTSPLV002B N Y B A 28 GL EH SV3MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (C6) STC Main Turbine Control Valve FST SV3MTSPLV003A N Y B A 28 GL EH SV3MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (E6) STC Main Turbine Stop Valve FST SV3MTSPLV003B N Y B A 28 GL EH SV3MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (D6) STC Main Turbine Stop Valve FST SV3MTSPLV004A N Y B A 28 GL EH SV3MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (E6) STC Main Turbine Control Valve FST SV3MTSPLV004B N Y B A 28 GL EH SV3MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (D6) STC Main Turbine Control Valve FST 28 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: PCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3PCSPLV001A 3 N B A 6 BU AO SV3PCSM6001 C O O PI (ISTC3700)

(E4) STO PCS Actuation Valve A FST SV3PCSPLV001B 3 N B A 6 BU AO SV3PCSM6001 C O O PI (ISTC3700)

(E6) STO PCS Actuation Valve B FST SV3PCSPLV001C 3 N B A 6 GA MO SV3PCSM6001 C O AI PI (III3300) This valve has a passive closed function (E5) STO for Spent fuel makeup.

III3100 PCS Actuation Valve C III3300 SV3PCSPLV002A 3 N B A 6 GA MO SV3PCSM6001 O O AI PI III3300) This valve has a passive closed function (E4) STO for Spent fuel makeup.

III3100 PCS Isolation Valve A III3300 SV3PCSPLV002B 3 N B A 6 GA MO SV3PCSM6001 O O AI PI III3300) This valve has a passive closed function (E6) STO for Spent fuel makeup.

III3100 PCS Isolation Valve B III3300 SV3PCSPLV002C 3 N B A 6 GA MO SV3PCSM6001 O O AI PI (III3300) This valve has a passive closed function (E5) STO for Spent fuel makeup.

III3100 PCS Isolation Valve C III3300 SV3PCSPLV005 3 N B A 4 GA MA SV3PCSM6002 O C AI ETM PCS to DWS/FPS Iso Valve (G5)

SV3PCSPLV009 3 N B A 3 GA MA SV3PCSM6001 C C/O AI ETM Open for Emergency SFP makeup Spent Fuel Pool Emergency Makeup Valve (E4)

SV3PCSPLV015 3 N B A 1 GL MA SV3PCSM6002 O C AI ETM PCS Long Term supply to Distribution Bucket Drain Valve (G8)

SV3PCSPLV020 3 N B A 3 GA MA SV3PCSM6002 C O AI ETM PCS Long Term supply to Distribution Bucket Iso Valve (G7) 29 Southern Nuclear Version 3.0

System: PCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3PCSPLV023 3 N B A 4 GA MA SV3PCSM6002 O C AI ETM PCS Recirc Pumps to PCCWST Iso Valve (F7)

SV3PCSPLV039 3 N C A 4 CK SA SV3PCSM6002 C O/C NA CKO PCS/SFS Long Term Makeup Supply Check Valve (F3) CKC SV3PCSPLV042 3 N B A 1 GL MA SV3PCSM6002 O C AI ETM PCS Long Term Supply from Temp Pump Drain Valve (F3)

SV3PCSPLV044 3 N B A 4 GA MA SV3PCSM6002 C O AI ETM PCS Long Term Supply from Temp Pump Iso Valve (F4)

SV3PCSPLV045 3 N B A 2 GL MA SV3PCSM6001 C O AI ETM PCS Supply to SFS Makeup Iso Valve (B3)

SV3PCSPLV046 3 N B A 4 GA MA SV3PCSM6002 O C AI ETM PCCWST Recirculation Return Isolation Valve (H7)

SV3PCSPLV049 3 N B A 1 GL MA SV3PCSM6001 O C AI ETM PCCWST Drain Isolation Valve (B2)

SV3PCSPLV050 3 N B A 2 GL MA SV3PCSM6002 C C/O AI ETM Recirc Header Discharge to SFS Pool Isolation Valve (F7)

SV3PCSPLV051 3 N B A 2 GL MA SV3PCSM6001 C C/O AI ETM Spent Fuel Pool Emergency Makeup Lower Isolation Valve (B2) 30 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: PSS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3PSSPLV001A 2 N C A 1/4 GL SO SV3PSSM6001 O O C RVT Thermal Relief function Hot Leg 1 Sample Isolation Valve E8 SV3PSSPLV001B 2 N C A 1/4 GL SO SV3PSSM6001 C O C RVT Thermal Relief function Hot Leg 2 Sample Isolation Valve D8 SV3PSSPLV003 2 N C A 1/4 GL SO SV3PSSM6001 C O C RVT Thermal Relief function Pressurizer Sample Isolation Valve G8 SV3PSSPLV008 2 N A A 5/8 GL SO SV3PSSM6001 O C C PI (ISTC3700)

(D7) STC FST Containment Air Sample Containment Isolation Valve IRC LTApp. J SV3PSSPLV010A 2 N A AC 1/4 GL SO SV3PSSM6001 O C/O C PI (ISTC3700)

(D7) STC FST RVT Thermal Relief function Liquid Sample Line Containment Isolation Valve IRC LTApp. J SV3PSSPLV010B 2 N A AC 1/4 GL SO SV3PSSM6001 C C/O C PI (ISTC3700)

(G7) STC FST RVT Thermal Relief function Liquid Sample Line Containment Isolation Valve IRC LTApp. J SV3PSSPLV011A 2 N A A 1/4 GL AO SV3PSSM6001 O C C PI (ISTC3700)

(E6) STC FST Liquid Sample Line Containment Isolation Valve ORC LTApp. J SV3PSSPLV011B 2 N A A 1/4 GL AO SV3PSSM6001 C C C PI (ISTC3700)

(G6) STC FST Liquid Sample Line Containment Isolation Valve ORC LTApp. J 31 Southern Nuclear Version 3.0

System: PSS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3PSSPLV023 2 N A A 1 GL AO SV3PSSM6001 O C C PI (ISTC3700)

(C6) STC FST Sample Return Line Containment Isolation Valve ORC LTApp. J SV3PSSPLV024 2 N A A 1 GL SO SV3PSSM6001 O C C PI (ISTC3700)

(C7) STC FST Sample Return Line Containment Isolation Valve IRC LTApp. J SV3PSSPLV046 2 N A A 5/8 GL AO SV3PSSM6001 O C C PI (ISTC3700)

(D6) STC FST Air Sample Line Containment Isolation Valve ORC LTApp. J 32 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: PWS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3PWSPLV418 3 N B A 1 GL MA SV3PWSM6002 O C AI ETM Control Room Boundary Outside Isolation Valve (G4)

SV3PWSPLV420 3 N B A 1 GL MA SV3PWSM6002 O C AI ETM Control Room Boundary Inside Isolation Valve (F4)

SV3PWSPLV498 3 N C A 1 VB SA SV3PWSM6002 C O NA VE(I7170)

(F4) RVT(I7270(a)) Actuation to verify open/close Control Room Boundary Vacuum Breaker RVT(I7270(b)) Leak tightness 33 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: PXS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3PXSPLV002A 1 N B P 8 GA MO SV3PXSM6001 O O AI PI (ISTC3700)

RCS to CMT A Isolation Valve (G/H5)

SV3PXSPLV002B 1 N B P 8 GA MO SV3PXSM6001 O O AI PI (ISTC3700)

RCS to CMT B Isolation Valve (G/H4)

SV3PXSPLV013A 1 N B P 8 GA MA SV3PXSM6001 LO O AI PI (ISTC3700)

CMT A Discharge Manual Isol Valve (D6)

SV3PXSPLV013B 1 N B P 8 GA MA SV3PXSM6001 LO O AI PI (ISTC3700)

CMT B Discharge Manual Isol Valve (D3)

SV3PXSPLV014A 1 N B A 8 GL AO SV3PXSM6001 C O O PI (ISTC3700)

(E7) STO CMT A Outlet Valve FST SV3PXSPLV014B 1 N B A 8 GL AO SV3PXSM6001 C O O PI (ISTC3700)

(E3) STO CMT B Outlet Valve FST SV3PXSPLV015A 1 N B A 8 GL AO SV3PXSM6001 C O O PI (ISTC3700)

(D7) STO CMT A Outlet Valve FST SV3PXSPLV015B 1 N B A 8 GL AO SV3PXSM6001 C O O PI (ISTC3700)

(D3) STO CMT B Outlet Valve FST SV3PXSPLV016A 1 N C A 8 CK SA SV3PXSM6001 O O/C NA CKO CMT A outlet to RCS Check (D6) CKC SV3PXSPLV016B 1 N C A 8 CK SA SV3PXSM6001 O O/C NA CKO CMT B outlet to RCS Check (D3) CKC SV3PXSPLV017A 1 N C A 8 CK SA SV3PXSM6001 O O/C NA CKO CMT A outlet to RCS Check (D6) CKC SV3PXSPLV017B 1 N C A 8 CK SA SV3PXSM6001 O O/C NA CKO CMT B outlet to RCS Check (D3) CKC SV3PXSPLV021A 3 N B P 1 GL SO SV3PXSM6001 C C C PI (ISTC3700)

Accumulator A Nitrogen supply Valve (C7) 34 Southern Nuclear Version 3.0

System: PXS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3PXSPLV021B 3 N B P 1 GL SO SV3PXSM6001 C C C PI (ISTC3700)

Accumulator B Nitrogen supply Valve (C2)

SV3PXSPLV022A 3 N C A 1 RV SA SV3PXSM6001 C O/C NA VE(I7150(a))

(C7) RVT(I7150(b)) Verify Vendor setpoint Accumulator A Relief Valve RVT(I7150(c)) Leak tightness (from Vendor test)

SV3PXSPLV022B 3 N C A 1 RV SA SV3PXSM6001 C O/C NA VE(I7150(a))

(C2) RVT(I7150(b)) Verify Vendor setpoint Accumulator B Relief Valve RVT(I7150(c)) Leak tightness (from Vendor test)

SV3PXSPLV027A 3 N B P 8 GA MO SV3PXSM6001 O O AI PI (ISTC3700)

Accumulator A to RCS Isolation Valve (B6)

SV3PXSPLV027B 3 N B P 8 GA MO SV3PXSM6001 O O AI PI (ISTC3700)

Accumulator B to RCS Isolation Valve (B3)

SV3PXSPLV028A 1 N AC A 8 CK SA SV3PXSM6001 C O/C NA CKO (B6) CKC Accumulator A outlet to RCS Check LT SV3PXSPLV028B 1 N AC A 8 CK SA SV3PXSM6001 C O/C NA CKO (B3) CKC Accumulator B outlet to RCS Check LT SV3PXSPLV029A 1 N AC A 8 CK SA SV3PXSM6001 C O/C NA CKO (B6) CKC Accumulator A outlet to RCS Check LT SV3PXSPLV029B 1 N AC A 8 CK SA SV3PXSM6001 C O/C NA CKO (B4) CKC Accumulator B outlet to RCS Check LT SV3PXSPLV042 2 N A A 1 GL AO SV3PXSM6001 O C C PI (ISTC3700)

(D1) STC FST High Pressure Nitrogen to Containment Isolation Valve LT App. J SV3PXSPLV043 2 N AC A 1 CK SA SV3PXSM6001 C O/C NA CKOP Accommodate thermal expansion (D2) CKC High Pressure Nitrogen to Containment IC Check Valve LT App. J SV3PXSPLV044 N N C A 1 RV SA SV3PXSM6001 C O NA VE(I7150(a))

(D2) RVT(I7150(b)) Verify Vendor setpoint High Pressure Nitrogen to Containment Penetration Thermal Relief Valve RVT(I7150(c)) Leak tightness (from Vendor test)

SV3PXSPLV101 1 N B P 14 GA MO SV3PXSM6002 O O AI PI (ISTC3700)

RCS to PRHR Heat Exchanger Isolation Valve (G 1) 35 Southern Nuclear Version 3.0

System: PXS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3PXSPLV108A 1 N B A 14 BA AO SV3PXSM6002 C O O PI (ISTC3700)

(F1) STO PRHR Heat Exchanger Outlet Valve to RCS A FST SV3PXSPLV108B 1 N B A 14 BA AO SV3PXSM6002 C O O PI (ISTC3700)

(E1) STO PRHR Heat Exchanger Outlet Valve to RCS B FST SV3PXSPLV109 1 N B P 14 GA MA SV3PXSM6002 LO O AI PI (ISTC3700)

PRHR HX/RCS Return Isol Valve (F1)

SV3PXSPLV117A 3 N B P 8 GA MO SV3PXSM6002 O O AI PI (ISTC3700)

Containment Recirculation Sump A to RCS Isolation Valve (E7)

SV3PXSPLV117B 3 N B P 8 GA MO SV3PXSM6002 O O AI PI (ISTC3700)

Containment Recirculation Sump B to RCS Isolation Valve (E5)

SV3PXSPLV118A 3 N D A 8 SQ SQ SV3PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump A to RCS Actuation Squib Valve (E7) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3PXSPLV118B 3 N D A 8 SQ SQ SV3PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump B to RCS Actuation Squib Valve (E5) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3PXSPLV119A 3 N C A 8 CK SA SV3PXSM6002 C O/C NA PI (ISTC3700)

(D7) CKO Containment Recirc. Sump A outlet to RCS Check CKC SV3PXSPLV119B 3 N C A 8 CK SA SV3PXSM6002 C O/C NA PI (ISTC3700)

(D5) CKO Containment Recirc. Sump B outlet to RCS Check CKC SV3PXSPLV120A 3 N D A 8 SQ SQ SV3PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump A to RCS Actuation Squib Valve (D7) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3PXSPLV120B 3 N D A 8 SQ SQ SV3PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump B to RCS Actuation Squib Valve (D5) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3PXSPLV121A 3 N B P 8 GA MO SV3PXSM6002 O O AI PI (ISTC3700)

IRWST/Recirc Sump to RCS A Isolation Valve (D7)

SV3PXSPLV121B 3 N B P 8 GA MO SV3PXSM6002 O O AI PI (ISTC3700)

IRWST/Recirc Sump to RCS B Isolation Valve (D5)

SV3PXSPLV122A 1 N C A 8 CK SA SV3PXSM6002 C O/C NA PI (ISTC3700)

(C7) CKO IRWST/Recirc Sump to RCS A outlet to RCS Check CKC SV3PXSPLV122B 1 N C A 8 CK SA SV3PXSM6002 C O/C NA PI (ISTC3700)

(C5) CKO IRWST/Recirc Sump to RCS B outlet to RCS Check CKC 36 Southern Nuclear Version 3.0

System: PXS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3PXSPLV123A 1 N D A 8 SQ SQ SV3PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump A to RCS Actuation Squib Valve (C7) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3PXSPLV123B 1 N D A 8 SQ SQ SV3PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump B to RCS Actuation Squib Valve (D5) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3PXSPLV124A 1 N C A 8 CK SA SV3PXSM6002 C O/C NA PI (ISTC3700)

(C7) CKO IRWST/Recirc Sump to RCS A outlet to RCS Check CKC SV3PXSPLV124B 1 N C A 8 CK SA SV3PXSM6002 C O/C NA PI (ISTC3700)

(C5) CKO IRWST/Recirc Sump to RCS B outlet to RCS Check CKC SV3PXSPLV125A 1 N D A 8 SQ SQ SV3PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump A to RCS Actuation Squib Valve (C7) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3PXSPLV125B 1 N D A 8 SQ SQ SV3PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump B to RCS Actuation Squib Valve (D5) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3PXSPLV130A 3 N B A 2 BA AO SV3PXSM6002 O C C PI (ISTC3700)

(H7) STC Containment Condensation Collection to Containment Sump Isolation Valve A FST SV3PXSPLV130B 3 N B A 2 BA AO SV3PXSM6002 O C C PI (ISTC3700)

(H7) STC Containment Condensation Collection to Containment Sump Isolation Valve B FST SV3PXSPLV208A 2 N A P .375 GL MA SV3PXSM6003 LC C C LTApp. J RNS Suction Leak Test Valve (D3)

SV3PXSPLV230A 2 N B P 1 GL AO SV3PXSM6003 C C C PI (ISTC3700)

Core Makeup Tank A Fill Isolation (F6)

SV3PXSPLV230B 2 N B P 1 GL AO SV3PXSM6003 C C C PI (ISTC3700)

Core Makeup Tank B Fill Isolation (G6)

SV3PXSPLV231A 2 N C A 1 CK SA SV3PXSM6003 C C C CKOP Accommodate thermal expansion Core Makeup Tank A Fill Check (F7) CKC SV3PXSPLV231B 2 N C A 1 CK SA SV3PXSM6003 C C C CKOP Accommodate thermal expansion Core Makeup Tank B Fill Check (G7) CKC SV3PXSPLV232A 3 N B P 1 GL AO SV3PXSM6003 C C C PI (ISTC3700)

Accumulator B Fill/Drain Isolation (E6)

SV3PXSPLV232B 3 N B P 1 GL AO SV3PXSM6003 C C C PI (ISTC3700)

Accumulator B Fill/Drain Isolation (G6) 37 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: RCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3RCSPLV001A 1 N B A 4 GL MO SV3RCSM6002 C O AI PI (III3300)

(G5) STO III3100 ADS Stage 1 Control Valve III3300 SV3RCSPLV001B 1 N B A 4 GL MO SV3RCSM6002 C O AI PI (III3300)

(E5) STO III3100 ADS Stage 1 Control Valve III3300 SV3RCSPLV002A 1 N B A 8 GL MO SV3RCSM6002 C O AI PI (III3300)

(G5) STO III3100 ADS Stage 2 Control Valve III3300 SV3RCSPLV002B 1 N B A 8 GL MO SV3RCSM6002 C O AI PI (III3300)

(E5) STO III3100 ADS Stage 2 Control Valve III3300 SV3RCSPLV003A 1 N B A 8 GL MO SV3RCSM6002 C O AI PI (III3300)

(H5) STO III3100 ADS Stage 3 Control Valve III3300 SV3RCSPLV003B 1 N B A 8 GL MO SV3RCSM6002 C O AI PI (III3300)

(F5) STO III3100 ADS Stage 3 Control Valve III3300 SV3RCSPLV004A 1 N D A 14 SQ SQ SV3RCSM6001 C O NA Circuit(ISTC3100(d)(1))

ADS Stage 4 Valve (G6) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3RCSPLV004B 1 N D A 14 SQ SQ SV3RCSM6001 C O NA Circuit(ISTC3100(d)(1))

ADS Stage 4 Valve (F3) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 38 Southern Nuclear Version 3.0

System: RCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3RCSPLV004C 1 N D A 14 SQ SQ SV3RCSM6001 C O NA Circuit(ISTC3100(d)(1))

ADS Stage 4 Valve (F6) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3RCSPLV004D 1 N D A 14 SQ SQ SV3RCSM6001 C O NA Circuit(ISTC3100(d)(1))

ADS Stage 4 Valve (F3) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV3RCSPLV005A 1 N C A 6 RV SA SV3RCSM6002 C O/C NA PI (I7110(c)/7310(f)) From Vendor test (H7) RVT(I7110(b)) Verify Vendor setpoint RVT(I7110(d)) Leak tightness per Vendor test VE(I7110(a))

RVT(I7210) Setpoint verification (due 6m prior to Initial Pressurizer Safety Valve Criticality) Alternative VEGP 3&4PSTAlt02 SV3RCSPLV005B 1 N C A 6 RV SA SV3RCSM6002 C O/C NA PI (I7110(c)/7310(f)) From Vendor test (F6) RVT(I7110(b)) Verify Vendor setpoint RVT(I7110(d)) Leak tightness per Vendor test VE(I7110(a))

RVT(I7210) Setpoint verification (due 6m prior to Initial Pressurizer Safety Valve Criticality) Alternative VEGP 3&4PSTAlt02 SV3RCSPLV010A 3 N C A 1 VB SA SV3RCSM6002 C O NA VE(I7170)

(G4) RVT(I7270(a)) Actuation to verify open/close ADS Header Vacuum Breaker RVT(I7270(b)) Leak tightness SV3RCSPLV010B 3 N C A 1 VB SA SV3RCSM6002 C O NA VE(I7170)

(E4) RVT(I7270(a)) Actuation to verify open/close ADS Header Vacuum Breaker RVT(I7270(b)) Leak tightness SV3RCSPLV011A 1 N B A 4 GA MO SV3RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (G5) STO III3100 ADS Stage 1 Isolation Valve III3300 SV3RCSPLV011B 1 N B A 4 GA MO SV3RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (E5) STO III3100 ADS Stage 1 Isolation Valve III3300 SV3RCSPLV012A 1 N B A 8 GA MO SV3RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (G5) STO III3100 ADS Stage 2 Isolation Valve III3300 39 Southern Nuclear Version 3.0

System: RCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3RCSPLV012B 1 N B A 8 GA MO SV3RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (E5) STO III3100 ADS Stage 2 Isolation Valve III3300 SV3RCSPLV013A 1 N B A 8 GA MO SV3RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (H5) STO III3100 ADS Stage 3 Isolation Valve III3300 SV3RCSPLV013B 1 N B A 8 GA MO SV3RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (F5) STO III3100 ADS Stage 3 Isolation Valve III3300 SV3RCSPLV014A 1 N B P 14 GA MO SV3RCSM6001 O O AI PI (ISTC3700)

ADS Stage 4 Block Valve (G6)

SV3RCSPLV014B 1 N B P 14 GA MO SV3RCSM6001 O O AI PI (ISTC3700)

ADS Stage 4 Block Valve (F3)

SV3RCSPLV014C 1 N B P 14 GA MO SV3RCSM6001 O O AI PI (ISTC3700)

ADS Stage 4 Block Valve (F6)

SV3RCSPLV014D 1 N B P 14 GA MO SV3RCSM6001 O O AI PI (ISTC3700)

ADS Stage 4 Block Valve (F3)

SV3RCSPLV150A 1 N B A 1 GL SO SV3RCSM6001 C O/C C PI (ISTC3700)

(D4) STO STC FST Reactor Head Vent Valve RVT Thermal Relief function SV3RCSPLV150B 1 N B A 1 GL SO SV3RCSM6001 C O/C C PI (ISTC3700)

(D4) STO STC FST Reactor Head Vent Valve RVT Thermal Relief function SV3RCSPLV150C 1 N B A 1 GL SO SV3RCSM6001 C O/C C PI (ISTC3700)

(D4) STO STC Reactor Head Vent Valve FST 40 Southern Nuclear Version 3.0

System: RCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3RCSPLV150D 1 N B A 1 GL SO SV3RCSM6001 C O/C C PI (ISTC3700)

(D4) STO STC Reactor Head Vent Valve FST SV3RCSPLV233 3 N B P 2 GL MA SV3RCSM6002 O O AI PI (ISTC3700) Open only indication RV Head Vent to IRWST Isolation Valve (H3)

SV3RCSPYK03 3 N D A 10 RD SA SV3RCSM6002 C O NA VE(I7160/7260)

Pressurizer Relief Valve Discharge Line Rupture Disc (H8)

SV3RCSPYK04 3 N D A 10 RD SA SV3RCSM6002 C O NA VE(I7160/7260)

Pressurizer Relief Valve Discharge Line Rupture Disc (F7) 41 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: RNS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3RNSPLV001A 1 N A A 10 GA MO SV3RNSM6001 C C AI PI (III3300)

(F2) STC III3100 III3300 RNS Suction from RCS Inner Isolation Valve LT SV3RNSPLV001B 1 N A A 10 GA MO SV3RNSM6001 C C AI PI (III3300)

(D2) STC III3100 III3300 RNS Suction from RCS Inner Isolation Valve LT SV3RNSPLV002A 1 N A A 10 GA MO SV3RNSM6001 C C AI PI (III3300)

(F2) STC III3100 III3300 LT RNS Suction from RCS Outer Isolation /IC Containment Isolation Valve LTApp. J SV3RNSPLV002B 1 N A A 10 GA MO SV3RNSM6001 C C AI PI (III3300)

(D2) STC III3100 III3300 LT RNS Suction from RCS Outer Isolation /IC Containment Isolation Valve LTApp. J SV3RNSPLV003A 2 N C A 1 CK SA SV3RNSM6001 C O NA CKOP Accommodate thermal expansion RNS PIV Thermal Relief Valve (G2) CKC SV3RNSPLV003B 2 N C A 1 CK SA SV3RNSM6001 C O NA CKOP Accommodate thermal expansion RNS PIV Thermal Relief Valve (D2) CKC SV3RNSPLV011 2 N A A 8 GA MO SV3RNSM6001 C C AI PI (III3300)

(F7) STC III3100 III3300 RNS Discharge Header to Containment OC Containment Isolation Valve LTApp. J 42 Southern Nuclear Version 3.0

System: RNS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3RNSPLV012 2 N A A 1 GL MA SV3RNSM6001 C C/O AI ETM PostAccident Long Term RCS Makeup & Containment Isolation Valve (G7) LTApp. J SV3RNSPLV013 2 N AC A 8 CK SA SV3RNSM6001 C C/O NA CKO Accommodate thermal expansion (F7) CKC RNS to Containment IC Containment Isolation Valve LTApp. J SV3RNSPLV015A 1 N AC A 6 CK SA SV3RNSM6001 C C/O NA CKO Accommodate thermal expansion (F8) CKC RNS to DVI Stop Check Valve LT SV3RNSPLV015B 1 N AC A 6 CK SA SV3RNSM6001 C C/O NA CKO Accommodate thermal expansion (F8) CKC RNS to DVI Stop Check Valve LT SV3RNSPLV017A 1 N AC A 6 CK SA SV3RNSM6001 C C/O NA CKO Accommodate thermal expansion (F8) CKC RNS to DVI Check Valve LT SV3RNSPLV017B 1 N AC A 6 CK SA SV3RNSM6001 C C/O NA CKO Accommodate thermal expansion (F8) CKC RNS to DVI Check Valve LT SV3RNSPLV020 2 N AC A 1 RV SA SV3RNSM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (G2) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

RNS Suction Relief Valve LTApp. J SV3RNSPLV021 2 N AC A 3 RV SA SV3RNSM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (G2) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

RNS Suction Relief Valve LTApp. J SV3RNSPLV022 2 N A A 10 GA MO SV3RNSM6001 C C AI PI (III3300)

(F3) STC III3100 III3300 RNS Suction from RCS OC Containment Isolation Valve LTApp. J SV3RNSPLV023 2 N A A 10 GA MO SV3RNSM6001 C C AI PI (III3300)

(E3) STC III3100 III3300 RNS Suction from IRWST/IC Containment Isolation Valve LTApp. J 43 Southern Nuclear Version 3.0

System: RNS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3RNSPLV061 2 N A A 3 GL AO SV3RNSM6001 C C C PI (ISTC3700)

(G3) STC FST CVS return to RNS Suction/IC Containment Isolation Valve LTApp. J 44 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: SDS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3SDSPLV001 3 N B A 3 BU MO SV3SDSM6001 O C AI PI (III3300)

(E5) STC III3100 MCR SDS (Vent) Isolation Valve III3300 SV3SDSPLV002 3 N B A 3 BU MO SV3SDSM6001 O C AI PI (III3300)

(E5) STC III3100 MCR SDS (Vent) Isolation Valve III3300 45 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: SFS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3SFSPLV031 3 N B P 6 BU MA SV3SFSM6001 LO O AI PI (ISTC3700)

Refueling Cavity Drain to S/G 2 Compartment Isolation Valve (F7)

SV3SFSPLV033 3 N B P 2 PL MA SV3SFSM6001 LC C AI PI (ISTC3700)

Refueling Cavity Drain to Containment Sump Isolation Valve (E7)

SV3SFSPLV034 2 N A A 6 BU MO SV3SFSM6001 C C AI PI (III3300)

(D6) STC III3100 III3300 Refueling Cavity/IRWST to SFS IC Containment Iso Valve LTApp. J SV3SFSPLV035 2 N A A 6 BU MO SV3SFSM6001 C C AI PI (III3300)

(D5) STC III3100 III3300 Refueling Cavity/IRWST to SFS OC Containment Iso Valve LTApp. J SV3SFSPLV037 2 N AC A 4 CK SA SV3SFSM6001 C C/O NA CKC (B6) CKOP Accommodate thermal expansion SFS to Refueling Cavity/IRWST IC Containment Iso Valve LTApp. J SV3SFSPLV038 2 N A A 4 BU MO SV3SFSM6001 C C AI PI (III3300)

(B5) STC III3100 III3300 SFS to Refueling Cavity/IRWST OC Containment Iso Valve LTApp. J SV3SFSPLV041 3 N B A 6 BU MA SV3SFSM6001 LC C AI ETM SFS Cask Loading Pit Suction Isolation Valve (F1)

SV3SFSPLV066 3 N B A 2 BA MA SV3SFSM6001 LC C/O AI ETM Spent Fuel Pool Boiloff Makeup Isolation Valve (F3)

SV3SFSPLV067 2 N AC A 1 RV SA SV3SFSM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (E6) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Refueling Cavity/IRWST to SFS Penetration Relief Valve LTApp. J 46 Southern Nuclear Version 3.0

System: SFS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3SFSPLV068 3 N B A 4 BU MA SV3SFSM6001 LO O AI ETM SFS Cask Washdown Pit Drain Isolation Valve (F2)

SV3SFSPLV071 3 N C A 6 CK SA SV3SFSM6001 C O/C NA CKO Refueling Cavity/IRWST to SFS Penetration Relief Valve (E6) CKC SV3SFSPLV072 3 N C A 6 CK SA SV3SFSM6001 C O/C NA CKO Refueling Cavity/IRWST to SFS Penetration Relief Valve (E6) CKC SV3SFSPLV075 3 N B P 20 BU MA SV3SFSM6001 LO O AI PI (ISTC3700)

SFS Reactor Cavity PostAccident Containment Floodup Valve (G7) 47 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3SGSPLV027A 2 N B A 12 GL MO SV3SGSM6001 O C AI PI (III3300)

(G2) STC III3100 SG 1 PORV Isolation valve III3300 SV3SGSPLV027B 2 N B A 12 GL MO SV3SGSM6002 O C AI PI (III3300)

(G2) STC III3100 SG 2 PORV Isolation valve III3300 SV3SGSPLV030A 2 N C A 8X10 RV SA SV3SGSM6001 C O/C NA VE(I7150(a))

(G4/5) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV030B 2 N C A 8X10 RV SA SV3SGSM6002 C O/C NA VE(I7150(a))

(G4/5) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV031A 2 N C A 8X10 RV SA SV3SGSM6001 C O/C NA VE(I7150(a))

(G4) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test 48 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3SGSPLV031B 2 N C A 8X10 RV SA SV3SGSM6002 C O/C NA VE(I7150(a))

(G4) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV032A 2 N C A 8X10 RV SA SV3SGSM6001 C O/C NA VE(I7150(a))

(G4) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV032B 2 N C A 8X10 RV SA SV3SGSM6002 C O/C NA VE(I7150(a))

(G4) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV033A 2 N C A 8X10 RV SA SV3SGSM6001 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV033B 2 N C A 8X10 RV SA SV3SGSM6002 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test 49 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3SGSPLV034A 2 N C A 8X10 RV SA SV3SGSM6001 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV034B 2 N C A 8X10 RV SA SV3SGSM6002 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV035A 2 N C A 8X10 RV SA SV3SGSM6001 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV035B 2 N C A 8X10 RV SA SV3SGSM6002 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV3SGSPLV036A 2 N B A 2 GL AO SV3SGSM6001 O C C PI (ISTC3700)

(G3) STC SG1 Steam Line Drain Isolation FST SV3SGSPLV036B 2 N B A 2 GL AO SV3SGSM6002 O C C PI (ISTC3700)

(G3) STC SG2 Steam Line Drain Isolation FST 50 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3SGSPLV040A 2 N B A 38 GA PH SV3SGSM6001 O C C PI (ISTC3700)

(G1) STC SG 1 Main Steam Isolation Valve FST SV3SGSPLV040B 2 N B A 38 GA PH SV3SGSM6002 O C C PI (ISTC3700)

(G1) STC SG 2 Main Steam Isolation Valve FST SV3SGSPLV057A 2 N B A 20 GA PH SV3SGSM6001 O C C PI (ISTC3700)

(E4) STC SG 1 Main Feedwater Isolation Valve FST SV3SGSPLV057B 2 N B A 20 GA PH SV3SGSM6002 O C C PI (ISTC3700)

(E4) STC SG 2 Main Feedwater Isolation Valve FST SV3SGSPL058A 2 N C A 20 CK SA SV3SGSM6001 O C/O NA CKOP Accommodate thermal expansion SG1 Main Feed Check Valve (E5) CKC SV3SGSPL058B 2 N C A 20 CK SA SV3SGSM6002 O C/O NA CKOP Accommodate thermal expansion SG2 Main Feed Check Valve (E5) CKC SV3SGSPLV067A 2 N B A 6 GA MO SV3SGSM6001 O C AI PI (III3300)

(D5) STC III3100 SG 1 Startup Feedwater Isolation Valve III3300 SV3SGSPLV067B 2 N B A 6 GA MO SV3SGSM6002 O C AI PI (III3300)

(D5) STC III3100 SG 2 Startup Feedwater Isolation Valve III3300 SV3SGSPLV074A 2 N B A 4 GL AO SV3SGSM6001 O C C PI (ISTC3700)

(C5) STC SG 1 Blowdown Isolation Valve FST SV3SGSPLV074B 2 N B A 4 GL AO SV3SGSM6002 O C C PI (ISTC3700)

(C5) STC SG 2 Blowdown Isolation Valve FST SV3SGSPLV075A 3 N B A 4 GL AO SV3SGSM6001 O C C PI (ISTC3700)

(C5) STC SG 1 Blowdown Isolation Valve Secondoff FST 51 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3SGSPLV075B 3 N B A 4 GL AO SV3SGSM6002 O C C PI (ISTC3700)

(C5) STC SG 2 Blowdown Isolation Valve Secondoff FST SV3SGSPLV086A 3 N B A 2 GL AO SV3SGSM6001 C C C PI (ISTC3700)

(F3) STC SG1 Steam Line Drain Level Control FST SV3SGSPLV086B 3 N B A 2 GL AO SV3SGSM6002 C C C PI (ISTC3700)

(F3) STC SG2 Steam Line Drain Level Control FST SV3SGSPLV233A 3 N B A 12 GL AO SV3SGSM6001 C C C PI (ISTC3700)

(H2) STC SG 1 Power Operated Relief Valve (PORV) FST SV3SGSPLV233B 3 N B A 12 GL AO SV3SGSM6002 C C C PI (ISTC3700)

(H2) STC SG 2 Power Operated Relief Valve (PORV) FST SV3SGSPLV240A 2 N B A 3 GL AO SV3SGSM6001 C C C PI (ISTC3700)

(G1) STC SG 1 MSIV Bypass Valve FST SV3SGSPLV240B 2 N B A 3 GL AO SV3SGSM6002 C C C PI (ISTC3700)

(G1) STC SG 2 MSIV Bypass Valve FST SV3SGSPLV250A 3 N B A 20 GL AO SV3SGSM6001 O C C PI (ISTC3700)

(E2/3) STC SG 1 Feedwater Control Valve FST SV3SGSPLV250B 3 N B A 20 GL AO SV3SGSM6002 O C C PI (ISTC3700)

(E2/3) STC SG 2 Feedwater Control Valve FST SV3SGSPLV255A 3 N B A 6 GL AO SV3SGSM6001 C C C PI (ISTC3700)

(D4) STC SG 1 Startup Feedwater Control Valve FST SV3SGSPLV255B 3 N B A 6 GL AO SV3SGSM6002 C C C PI (ISTC3700)

(D4) STC SG 2 Startup Feedwater Control Valve FST 52 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3SGSPL256A 2 N C A 6 CK SA SV3SGSM6001 C O NA CKOP Accommodate thermal expansion SG1 Startup Feedwater Check Valve (D4) CKC SV3SGSPL256B 2 N C A 6 CK SA SV3SGSM6002 C O NA CKOP Accommodate thermal expansion SG2 Startup Feedwater Check Valve (D4) CKC SV3SGSPLV257A 3 N C A 1 RV SA SV3SGSM6001 C O NA RVT(I7150(b)) Verify Vendor setpoint (E4) RVT(I7150(c)) Leak tightness per Vendor test Main Feedwater Thermal Relief VE(I7150(a))

SV3SGSPLV257B 3 N C A 1 RV SA SV3SGSM6002 C O NA RVT(I7150(b)) Verify Vendor setpoint (E4) RVT(I7150(c)) Leak tightness per Vendor test Main Feedwater Thermal Relief VE(I7150(a))

SV3SGSPLV258A 3 N C A 1 RV SA SV3SGSM6001 C O NA RVT(I7150(b)) Verify Vendor setpoint (D4) RVT(I7150(c)) Leak tightness per Vendor test Startup Feedwater Thermal Relief VE(I7150(a))

SV3SGSPLV258B 3 N C A 1 RV SA SV3SGSM6002 C O NA RVT(I7150(b)) Verify Vendor setpoint (D4) RVT(I7150(c)) Leak tightness per Vendor test Startup Feedwater Thermal Relief VE(I7150(a))

53 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: VBS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3VBSPLV186 3 N B A 28 BU MO SV3VBSM6007 O C AI PI (III3300)

(F6) STC III3100 MCR Supply Air Isolation Valve III3300 SV3VBSPLV187 3 N B A 28 BU MO SV3VBSM6007 O C AI PI (III3300)

(F6) STC III3100 MCR Supply Air Isolation Valve III3300 SV3VBSPLV188 3 N B A 28 BU MO SV3VBSM6007 O C AI PI (III3300)

(C7) STC III3100 MCR Return Air Isolation Valve III3300 SV3VBSPLV189 3 N B A 28 BU MO SV3VBSM6007 O C AI PI (III3300)

(C6) STC III3100 MCR Return Air Isolation Valve III3300 SV3VBSPLV190 3 N B A 6 BU MO SV3VBSM6007 O C AI PI (III3300)

(C3) STC III3100 MCR Toilet Exhaust Isolation Valve III3300 SV3VBSPLV191 3 N B A 6 BU MO SV3VBSM6007 O C AI PI (III3300)

(C3) STC III3100 MCR Toilet Exhaust Isolation Valve III3300 54 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: VES Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3VESPLV001 3 N B A 1 GL MA SV3VESM6002 C O/C AI ETM Air Delivery Isolation Valve (D5)

SV3VESPLV005A 3 N B A 1 GL SO SV3VESM6002 C O O PI (ISTC3700)

(F5) STO Air Delivery Isolation Valve A FST SV3VESPLV005B 3 N B A 1 GL SO SV3VESM6002 C O O PI (ISTC3700)

(E5) STO Air Delivery Isolation Valve B FST SV3VESPLV018 3 N B A 1 GL MA SV3VESM6002 C O/C AI ETM Temporary InstrumentationIsolation Valve (F5)

SV3VESPLV019 3 N B A 1 GL MA SV3VESM6002 C O/C AI ETM Temporary InstrumentationIsolation Valve (D5)

SV3VESPLV022A 3 N B A 4 BU AO SV3VESM6002 C O O PI (ISTC3700)

(C2) STO Pressure Relief Isolation Valve A FST SV3VESPLV022B 3 N B A 4 BU AO SV3VESM6002 C O O PI (ISTC3700)

(C2) STO Pressure Relief Isolation Valve B FST SV3VESPLV040A 3 N C A 1 RV SA SV3VESM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (H4) RVT(I7150(c)) Leak tightness per Vendor test Air Tank Safety Relief Valve A VE(I7150(a))

SV3VESPLV040B 3 N C A 1 RV SA SV3VESM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (F4) RVT(I7150(c)) Leak tightness per Vendor test Air Tank Safety Relief Valve B VE(I7150(a))

SV3VESPLV040C 3 N C A 1 RV SA SV3VESM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (E4) RVT(I7150(c)) Leak tightness per Vendor test Air Tank Safety Relief Valve C VE(I7150(a))

55 Southern Nuclear Version 3.0

System: VES Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3VESPLV040D 3 N C A 1 RV SA SV3VESM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (C4) RVT(I7150(c)) Leak tightness per Vendor test Air Tank Safety Relief Valve D VE(I7150(a))

SV3VESPLV044 3 N B A 1 GL MA SV3VESM6002 LO O/C AI ETM Eductor Flow Path Isolation Valve (F4)

SV3VESPLV045 3 N B A 1 GL MA SV3VESM6002 LO O/C AI ETM Eductor Flow Path Isolation Valve (E3)

SV3VESPLV046 3 N B A 1 GL MA SV3VESM6002 C O/C AI ETM Eductor Bypass Isolation Valve (D3) 56 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: VFS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3VFSPLV003 2 N A A 16 BU AO SV3VFSM6001 C C C PI (ISTC3700)

(B4) STC FST Containment Purge Inlet Containment Isol ORC LTApp. J SV3VFSPLV004 2 N A A 16 BU AO SV3VFSM6001 C C C PI (ISTC3700)

(B3) STC FST Containment Purge Inlet Containment Isol IRC LTApp. J SV3VFSPLV009 2 N A A 16 BU AO SV3VFSM6001 C C C PI (ISTC3700)

(D8) STC FST Containment Purge Discharge Containment Isol IRC LTApp. J SV3VFSPLV010 2 N A A 16 BU AO SV3VFSM6001 C C C PI (ISTC3700)

(D7) STC FST Containment Purge Discharge Containment Isol ORC LTApp. J SV3VFSPLV800A 2 N A A 6 BU MO SV3VFSM6001 C O/C AI PI (III3300)

(E7) STC STO III3100 III3300 Containment Vacuum Relief Isolation Valve A ORC LTApp. J SV3VFSPLV800B 2 N A A 6 BU MO SV3VFSM6001 C O/C AI PI (III3300)

(E7) STC STO III3100 III3300 Containment Vacuum Relief Isolation Valve B ORC LTApp. J SV3VFSPLV803A 2 N AC A 6 VB SA SV3VFSM6001 C O/C NA VE(I7170) Vacuum Relief (E7) RVT(I7270(a)) Actuation to verify open/close Containment Vacuum Relief Valve A - IRC LTApp. J Also meets LT requirements of I7270(b) 57 Southern Nuclear Version 3.0

System: VFS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3VFSPLV803B 2 N AC A 6 VB SA SV3VFSM6001 C O/C NA VE(I7170) Vacuum Relief (E7) RVT(I7270(a)) Actuation to verify open/close Containment Vacuum Relief Valve B - IRC LTApp. J Also meets LT requirements of I7270(b) 58 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: VWS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3VWSPLV053 3 N C A 2 RV SA SV3VWSM6003 C O NA RVT(I7150(b)) Verify Vendor setpoint (B6) RVT(I7150(c)) Leak tightness per Vendor test Ctmt Cooling Unit Supply Hdr Relief VE(I7150(a))

SV3VWSPLV057 3 N C A 2 RV SA SV3VWSM6003 C O NA RVT(I7150(b)) Verify Vendor setpoint (H4) RVT(I7150(c)) Leak tightness per Vendor test Ctmt Cooling Unit Return Hdr Relief VE(I7150(a))

SV3VWSPLV058 2 N A A 8 BU AO SV3VWSM6003 O C C PI (ISTC3700)

(B6) STC FST Chilled Water Inlet Containment Isolation Valve LT App. J SV3VWSPLV062 2 N AC A 8 CK SA SV3VWSM6003 O C/O NA CKC (B6) CKOP Accommodate thermal expansion Fan Coolers Supply IC Isol Check Valve LT App. J SV3VWSPLV080 2 N AC A 1 RV SA SV3VWSM6003 C C/O NA RVT(I7150(b)) Verify Vendor setpoint (H4) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Ctmt Cooling Unit Return CIV Relief LT App. J SV3VWSPLV082 2 N A A 8 BU AO SV3VWSM6003 O C C PI (ISTC3700)

(G3) STC FST Chilled Water Outlet Containment Isolation Valve LT App. J SV3VWSPLV086 2 N A A 8 BU AO SV3VWSM6003 O C C PI (ISTC3700)

(G3) STC FST Chilled Water Outlet Containment Isolation Valve LT App. J 59 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 3 System: WLS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3WLSPLV055 2 N A A 2 PL AO SV3WLSM6001 C C C PI (ISTC3700)

(C4) STC FST Containment Sump Discharge CIV - IRC LTApp. J SV3WLSPLV057 2 N A A 2 PL AO SV3WLSM6001 C C C PI (ISTC3700)

(C3) STC FST Containment Sump Discharge CIV - ORC LTApp. J SV3WLSPLV058 2 N AC A 1 RV SA SV3WLSM6001 C C/O NA RVT(I7150(b)) Verify Vendor setpoint (C4) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Containment Sump Discharge Penetration Thermal Relief LTApp. J SV3WLSPLV067 2 N A A 1 GL AO SV3WLSM6001 C C C PI (ISTC3700)

(E3) STC FST RCDT Gas Outlet CIV IRC LTApp. J SV3WLSPLV068 2 N A A 1 GL AO SV3WLSM6001 C C C PI (ISTC3700)

(E3) STC FST RCDT Gas Outlet CIV ORC LTApp. J SV3WLSPLV071A 3 N C A 4 CK SA SV3WLSM6001 C O/C NA CKO CVS Compt Floor Drain Check (C8) CKC SV3WLSPLV071B 3 N C A 4 CK SA SV3WLSM6001 C O/C NA CKO PXS Compt A Floor Drain Check (F8) CKC SV3WLSPLV071C 3 N C A 4 CK SA SV3WLSM6001 C O/C NA CKO PXS Compt B Floor Drain Check (F8) CKC SV3WLSPLV072A 3 N C A 4 CK SA SV3WLSM6001 C O/C NA CKO CVS Compt Floor Drain Check (C7) CKC SV3WLSPLV072B 3 N C A 4 CK SA SV3WLSM6001 C O/C NA CKO PXS Compt A Floor Drain Check (F8) CKC 60 Southern Nuclear Version 3.0

System: WLS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV3WLSPLV072C 3 N C A 4 CK SA SV3WLSM6001 C O/C NA CKO PXS Compt B Floor Drain Check (F8) CKC 61 Southern Nuclear Version 3.0

8.0 VEGP4 VALVE TABLES 62 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: CAS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4CASPLV014 2 N A A 2 BA AO SV4CASM6005 O C C PI (ISTC3700)

(F3) STC FST Instrument Air Containment Isolation Valve LTApp. J SV4CASPLV015 2 N AC A 2 CK SA SV4CASM6005 O C/O NA CKC (F4) CKOP Accommodate thermal expansion Instrument Air Containment Isolation Check Valve LTApp. J SV4CASPLV204 2 N A P 3 BA MA SV4CASM6012 LC C C LTApp. J Service Air Containment Isolation Valve (E5)

SV4CASPLV205 2 N AC A 3 CK SA SV4CASM6012 C C/O NA CKC (E4) CKOP Accommodate thermal expansion Service Air Containment Isolation Check Valve LTApp. J 63 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: CCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4CCSPLV200 2 N A A 10 BU MO SV4CCSM6002 O C AI PI (III3300)

(H2) STC III3100 III3300 Cooling Water Supply Ctmt Isol ORC LTApp. J SV4CCSPLV201 2 N AC A 10 CK SA SV4CCSM6002 O C/O NA CKC (H2) CKOP Accommodate thermal expansion Cooling Water Ctmt Supply Check LTApp. J SV4CCSPLV207 2 N A A 10 BU MO SV4CCSM6002 O C AI PI (III3300)

(B2) STC III3100 III3300 Cooling Water Return Ctmt Isol - IRC LTApp. J SV4CCSPLV208 2 N A A 10 BU MO SV4CCSM6002 O C AI PI (III3300)

(B1) STC III3100 III3300 Cooling Water Return Ctmt Isol ORC LTApp. J SV4CCSPLV220 2 N AC A 1 RV SA SV4CCSM6002 C C/O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (C2) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Ctmt Return CIV Thermal Relief LTApp. J SV4CCSPLV270 3 N C A 4 RV SA SV4CCSM6002 C O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (H2) RVT(I7150(c)) Leak tightness per Vendor test CCS Supply Line to Ctmt Safety/Relief VE(I7150(a))

SV4CCSPLV271 3 N C A 4 RV SA SV3CCSM6002 C O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (C2) RVT(I7150(c)) Leak tightness per Vendor test CCS Return Line to Ctmt Safety/Relief VE(I7150(a))

64 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: CVS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4CVSPLV001 1 N B A 3 GA MO SV4CVSM6001 O C AI PI (III3300)

(G8) STC III3100 CVS Purification Stop Valve III3300 SV4CVSPLV002 1 N B A 3 GA MO SV4CVSM6001 O C AI PI (III3300)

(G7) STC III3100 CVS Purification Stop Valve III3300 SV4CVSPLV003 3 N B A 3 GL MO SV4CVSM6001 O C AI PI (III3300)

(G7) STC III3100 CVS Purification Stop Valve III3300 SV4CVSPLV040 2 N A P 2 BA MA SV4CVSM6005 LC C AI LTApp. J Resin Flush Inside Containment Isolation Valve (F4)

SV4CVSPLV041 2 N A P 2 BA MA SV4CVSM6005 LC C AI LTApp. J Resin Flush Outside Containment Isolation Valve (F2)

SV4CVSPLV042 2 N AC A 1 RV SA SV4CVSM6005 C C/O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (G4) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Flush Line Containment Isolation Relief Valve LTApp. J SV4CVSPLV045 2 N A A 2 GL AO SV4CVSM6005 C C C PI (ISTC3700)

(D4) STC FST Letdown Line Inside Containment Isolation Valve LTApp. J SV4CVSPLV047 2 N A A 2 GL AO SV4CVSM6005 C C C PI (ISTC3700)

(D2) STC FST Letdown Line Outside Containment Isolation Valve LTApp. J 65 Southern Nuclear Version 3.0

System: CVS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4CVSPLV058 2 N AC A 1 RV SA SV4CVSM6005 C C/O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (E4) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Letdown Line Relief Thermal Relief Valve LTApp. J SV4CVSPLV064 N N C A 3 CK SA SV4CVSM6005 C O NA CKC Makeup Discharge Header Check Valve (C5) CKOP Accommodate thermal expansion SV4CVSPLV067 1 N C A 1 CK SA SV4CVSM6001 O C/O NA CKC Makeup Return Line SpringAssisted Check Valve (F7) CKOP Accommodate thermal expansion SV4CVSPLV080 3 N C A 3 CK SA SV4CVSM6001 O C/O NA CKC Regen HX Shell Side Outlet Check Valve (G7) CKOP Accommodate thermal expansion SV4CVSPLV081 1 N BC A 3 SC AO SV4CVSM6001 O C NA PI (ISTC3700)

(G7) CKC Purification Return Line Stop Check Valve CKOP SV4CVSPLV082 1 N C A 3 CK SA SV4CVSM6001 O C/O NA CKC RCS Purification Return Line Check Valve (G8) CKOP Accommodate thermal expansion SV4CVSPLV084 1 N B A 2 GL AO SV4CVSM6001 C C C PI (ISTC3700)

(F7) STC Auxiliary Pressurizer Spray Line Isolation Valve FST SV4CVSPLV085 1 N C A 2 CK SA SV4CVSM6001 C C/O NA CKC Auxiliary Pressurizer Spray Line Valve CKOP Accommodate thermal expansion SV4CVSPLV090 2 N A A 3 GA MO SV4CVSM6005 O C AI PI (III3300)

(C2) STC III3100 III3300 Makeup Line Outside Containment Isolation Valve LTApp. J SV4CVSPLV091 2 N A A 3 GA MO SV4CVSM6005 O C AI PI (III3300)

(C4) STC III3100 III3300 Makeup Line Inside Containment Isolation Valve LTApp. J SV4CVSPLV092 2 N A A 1 GL AO SV4CVSM6003 O C C PI (ISTC3700)

(F6) STC FST Zinc Injection Containment Isolation Valve ORC LTApp. J 66 Southern Nuclear Version 3.0

System: CVS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4CVSPLV094 2 N A A 1 GL AO SV4CVSM6003 O C C PI (ISTC3700)

(F7) STC FST Zinc Injection Containment Isolation Valve IRC LTApp. J SV4CVSPLV098 2 N AC A 1 RV SA SV4CVSM6003 C C/O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (F6) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Zinc Injection Ctmt Isol Thermal Relief Valve LTApp. J SV4CVSPLV100 2 N AC A 1 CK SA SV4CVSM6005 O C/O NA CKC (B4) CKOP Accommodate thermal expansion Makeup Line Containment Isolation Relief LTApp. J SV4CVSPLV136A 3 N B A 2 BU AO SV4CVSM6004 C C C PI (ISTC3700)

(C4) STC Demineralized Water System Isolation Valve FST SV4CVSPLV136B 3 N B A 2 BU AO SV4CVSM6004 C C C PI (ISTC3700)

(C4) STC Demineralized Water System Isolation Valve FST SV4CVSPLV217 2 N AC A 1/2 CK SA SV4CVSM6003 O C/O NA CKC (D7) CKOP Accommodate thermal expansion Hydrogen Injection Containment Isolation Check Valve IRC LTApp. J SV4CVSPLV219 2 N A A 1/2 GL AO SV4CVSM6003 O C C PI (ISTC3700)

(D6) STC FST Hydrogen Injection Containment Isolation Valve ORC LTApp. J 67 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: DWS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4DWSPLV241 3 N C A 1 RV SA SV4DWSM6007 C O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (E5) RVT(I7150(c)) Leak tightness per Vendor test Demin Water Supply to Containment Relief VE(I7150(a))

SV4DWSPLV244 2 N A P 3 BU MA SV4DWSM6007 LC C AI LTApp. J Exercised during Shutdown and leaktest Demin Water Supply Containment Isolation Outside (E6)

SV4DWSPLV245 2 N AC A 2 CK SA SV4DWSM6007 C C/O NA CKC (E6) CKOP Accommodate thermal expansion Demin Water Supply Containment Isolation Check Valve IRC LTApp. J 68 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: FHS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4FHSPLV001 3 N B A 30 GA MA SV4SFSM6001 C C AI ETM Fuel Transfer Tube Isolation Valve (F6) 69 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: FPS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4FPSPLV050 2 N A P 6 BU MA SV4FPSM6004 LC C AI LTApp. J Exercised during Shutdown and leaktest Fire Water Containment Supply Isolation (F5)

SV4FPSPLV052 2 N AC A 6 CK SA SV4FPSM6004 C C/O NA CKC (F5) CKOP Accommodate thermal expansion Fire Water Supply Cont Isol Check Valve IRC LTApp. J SV4FPSPLV702 3 N C A 1 RV SA SV4FPSM6004 C O NA RVT(I7150(b)) Verify Vendor setpoint, Thermal Relief (F/G5) RVT(I7150(c)) Leak tightness per Vendor test Fire Water Supply IC Thermal Relief VE(I7150(a))

70 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: MSS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4MSSPLV001 N Y B A 16 GL AO SV4MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H8) STC Turbine Bypass Control Valve FST SV4MSSPLV002 N Y B A 16 GL AO SV4MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H7) STC Turbine Bypass Control Valve FST SV4MSSPLV003 N Y B A 16 GL AO SV4MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H6) STC Turbine Bypass Control Valve FST SV4MSSPLV004 N Y B A 16 GL AO SV4MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H4) STC Turbine Bypass Control Valve FST SV4MSSPLV005 N Y B A 16 GL AO SV4MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H3) STC Turbine Bypass Control Valve FST SV4MSSPLV006 N Y B A 16 GL AO SV4MSSM6001 C C C PI (ISTC3700) Required by TS 3.7.2 (H2) STC Turbine Bypass Control Valve FST SV4MSSPLV015A N Y B A 10 GL AO SV4MSSM6001 O C C PI (ISTC3700) Required by TS 3.7.2 (B6) STC MSR 2ND Stage Reheat Steam AO Isolation Valve FST SV4MSSPLV015B N Y B A 10 GL AO SV4MSSM6001 O C C PI (ISTC3700) Required by TS 3.7.2 (G6) STC ND MSR 2 Stage Reheat Steam AO Isolation Valve FST 71 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: MTS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4MTSPLV001A N Y B A 28 GL EH SV4MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (F6) STC Main Turbine Stop Valve FST SV4MTSPLV001B N Y B A 28 GL EH SV4MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (C6) STC Main Turbine Stop Valve FST SV4MTSPLV002A N Y B A 28 GL EH SV4MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (F6) STC Main Turbine Control Valve FST SV4MTSPLV002B N Y B A 28 GL EH SV4MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (C6) STC Main Turbine Control Valve FST SV4MTSPLV003A N Y B A 28 GL EH SV4MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (E6) STC Main Turbine Stop Valve FST SV4MTSPLV003B N Y B A 28 GL EH SV4MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (D6) STC Main Turbine Stop Valve FST SV4MTSPLV004A N Y B A 28 GL EH SV4MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (E6) STC Main Turbine Control Valve FST SV4MTSPLV004B N Y B A 28 GL EH SV4MTSM6002 O C C PI (ISTC3700) Required by TS 3.7.2 (D6) STC Main Turbine Control Valve FST 72 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: PCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4PCSPLV001A 3 N B A 6 BU AO SV4PCSM6001 C O O PI (ISTC3700)

(E4) STO PCS Actuation Valve A FST SV4PCSPLV001B 3 N B A 6 BU AO SV4PCSM6001 C O O PI (ISTC3700)

(E6) STO PCS Actuation Valve B FST SV4PCSPLV001C 3 N B A 6 GA MO SV4PCSM6001 C O AI PI (III3300) This valve has a passive closed function (E5) STO for Spent fuel makeup.

III3100 PCS Actuation Valve C III3300 SV4PCSPLV002A 3 N B A 6 GA MO SV4PCSM6001 O O AI PI (III3300) This valve has a passive closed function (E4) STO for Spent fuel makeup.

III3100 PCS Isolation Valve A III3300 SV4PCSPLV002B 3 N B A 6 GA MO SV4PCSM6001 O O AI PI (III3300) This valve has a passive closed function (E6) STO for Spent fuel makeup.

III3100 PCS Isolation Valve B III3300 SV4PCSPLV002C 3 N B A 6 GA MO SV4PCSM6001 O O AI PI (III3300) This valve has a passive closed function (E5) STO for Spent fuel makeup.

III3100 PCS Isolation Valve C III3300 SV4PCSPLV005 3 N B A 4 GA MA SV4PCSM6002 O C AI ETM PCS to DWS/FPS Iso Valve (G5)

SV4PCSPLV009 3 N B A 3 GA MA SV4PCSM6001 C C/O AI ETM Open for Emergency SFP makeup Spent Fuel Pool Emergency Makeup Valve (E4)

SV4PCSPLV015 3 N B A 1 GL MA SV4PCSM6002 O C AI ETM PCS Long Term supply to Distribution Bucket Drain Valve (G8)

SV4PCSPLV020 3 N B A 3 GA MA SV4PCSM6002 C O AI ETM PCS Long Term supply to Distribution Bucket Iso Valve (G7) 73 Southern Nuclear Version 3.0

System: PCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4PCSPLV023 3 N B A 4 GA MA SV4PCSM6002 O C AI ETM PCS Recirc Pumps to PCCWST Iso Valve (F7)

SV4PCSPLV039 3 N C A 4 CK SA SV4PCSM6002 C O/C NA CKO PCS/SFS Long Term Makeup Supply Check Valve (F3) CKC SV4PCSPLV042 3 N B A 1 GL MA SV4PCSM6002 O C AI ETM PCS Long Term Supply from Temp Pump Drain Valve (F3)

SV4PCSPLV044 3 N B A 4 GA MA SV4PCSM6002 C O AI ETM PCS Long Term Supply from Temp Pump Iso Valve (F4)

SV4PCSPLV045 3 N B A 2 GL MA SV4PCSM6001 C O AI ETM PCS Supply to SFS Makeup Iso Valve (B3)

SV4PCSPLV046 3 N B A 4 GA MA SV4PCSM6002 O C AI ETM PCCWST Recirculation Return Isolation Valve (H7)

SV4PCSPLV049 3 N B A 1 GL MA SV4PCSM6001 O C AI ETM PCCWST Drain Isolation Valve (B2)

SV4PCSPLV050 3 N B A 2 GL MA SV4PCSM6002 C C/O AI ETM Recirc Header Discharge to SFS Pool Isolation Valve (F7)

SV4PCSPLV051 3 N B A 2 GL MA SV4PCSM6001 C C/O AI ETM Spent Fuel Pool Emergency Makeup Lower Isolation Valve (B2) 74 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: PSS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4PSSPLV001A 2 N C A 1/4 GL SO SV4PSSM6001 O O C RVT Thermal Relief function Hot Leg 1 Sample Isolation Valve E8 SV4PSSPLV001B 2 N C A 1/4 GL SO SV4PSSM6001 C O C RVT Thermal Relief function Hot Leg 2 Sample Isolation Valve D8 SV4PSSPLV003 2 N C A 1/4 GL SO SV4PSSM6001 C O C RVT Thermal Relief function Pressurizer Sample Isolation Valve G8 SV4PSSPLV008 2 N A A 5/8 GL SO SV4PSSM6001 O C C PI (ISTC3700)

(D7) STC FST Containment Air Sample Containment Isolation Valve IRC LTApp. J SV4PSSPLV010A 2 N AC A 1/4 GL SO SV4PSSM6001 O C/O C PI (ISTC3700)

(D7) STC FST RVT Thermal Relief function Liquid Sample Line Containment Isolation Valve IRC LTApp. J SV4PSSPLV010B 2 N AC A 1/4 GL SO SV4PSSM6001 C C/O C PI (ISTC3700)

(G7) STC FST RVT Thermal Relief function Liquid Sample Line Containment Isolation Valve IRC LTApp. J SV4PSSPLV011A 2 N A A 1/4 GL AO SV4PSSM6001 O C C PI (ISTC3700)

(E6) STC FST Liquid Sample Line Containment Isolation Valve ORC LTApp. J SV4PSSPLV011B 2 N A A 1/4 GL AO SV4PSSM6001 C C C PI (ISTC3700)

(G6) STC FST Liquid Sample Line Containment Isolation Valve ORC LTApp. J 75 Southern Nuclear Version 3.0

System: PSS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4PSSPLV023 2 N A A 1 GL AO SV4PSSM6001 O C C PI (ISTC3700)

(C6) STC FST Sample Return Line Containment Isolation Valve ORC LTApp. J SV4PSSPLV024 2 N A A 1 GL SO SV4PSSM6001 O C C PI (ISTC3700)

(C7) STC FST Sample Return Line Containment Isolation Valve IRC LTApp. J SV4PSSPLV046 2 N A A 5/8 GL AO SV4PSSM6001 O C C PI (ISTC3700)

(D6) STC FST Air Sample Line Containment Isolation Valve ORC LTApp. J 76 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: PWS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4PWSPLV418 3 N B A 1 GL MA SV4PWSM6002 O C AI ETM Control Room Boundary Outside Isolation Valve (G4)

SV4PWSPLV420 3 N B A 1 GL MA SV4PWSM6002 O C AI ETM Control Room Boundary Inside Isolation Valve (F4)

SV4PWSPLV498 3 N C A 1 VB SA SV4PWSM6002 C O NA VE(I7170)

(F4) RVT(I7270(a)) Actuation to verify open/close Control Room Boundary Vacuum Breaker RVT(I7270(b)) Leak tightness 77 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: PXS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4PXSPLV002A 1 N B P 8 GA MO SV4PXSM6001 O O AI PI (ISTC3700)

RCS to CMT A Isolation Valve (G/H5)

SV4PXSPLV002B 1 N B P 8 GA MO SV4PXSM6001 O O AI PI (ISTC3700)

RCS to CMT B Isolation Valve (G/H4)

SV4PXSPLV013A 1 N B P 8 GA MA SV4PXSM6001 LO O AI PI (ISTC3700)

CMT A Discharge Manual Isol Valve (D6)

SV4PXSPLV013B 1 N B P 8 GA MA SV4PXSM6001 LO O AI PI (ISTC3700)

CMT B Discharge Manual Isol Valve (D3)

SV4PXSPLV014A 1 N B A 8 GL AO SV4PXSM6001 C O O PI (ISTC3700)

(E7) STO CMT A Outlet Valve FST SV4PXSPLV014B 1 N B A 8 GL AO SV4PXSM6001 C O O PI (ISTC3700)

(E3) STO CMT B Outlet Valve FST SV4PXSPLV015A 1 N B A 8 GL AO SV4PXSM6001 C O O PI (ISTC3700)

(D7) STO CMT A Outlet Valve FST SV4PXSPLV015B 1 N B A 8 GL AO SV4PXSM6001 C O O PI (ISTC3700)

(D3) STO CMT B Outlet Valve FST SV4PXSPLV016A 1 N C A 8 CK SA SV4PXSM6001 O O/C NA CKO CMT A outlet to RCS Check (D6) CKC SV4PXSPLV016B 1 N C A 8 CK SA SV4PXSM6001 O O/C NA CKO CMT B outlet to RCS Check (D3) CKC SV4PXSPLV017A 1 N C A 8 CK SA SV4PXSM6001 O O/C NA CKO CMT A outlet to RCS Check (D6) CKC SV4PXSPLV017B 1 N C A 8 CK SA SV4PXSM6001 O O/C NA CKO CMT B outlet to RCS Check (D3) CKC SV4PXSPLV021A 3 N B P 1 GL SO SV4PXSM6001 C C C PI (ISTC3700)

Accumulator A Nitrogen supply Valve (C7) 78 Southern Nuclear Version 3.0

System: PXS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4PXSPLV021B 3 N B P 1 GL SO SV4PXSM6001 C C C PI (ISTC3700)

Accumulator B Nitrogen supply Valve (C2)

SV4PXSPLV022A 3 N C A 1 RV SA SV4PXSM6001 C O/C NA VE(I7150(a))

(C7) RVT(I7150(b)) Verify Vendor setpoint Accumulator A Relief Valve RVT(I7150(c)) Leak tightness (from Vendor test)

SV4PXSPLV022B 3 N C A 1 RV SA SV4PXSM6001 C O/C NA VE(I7150(a))

(C2) RVT(I7150(b)) Verify Vendor setpoint Accumulator B Relief Valve RVT(I7150(c)) Leak tightness (from Vendor test)

SV4PXSPLV027A 3 N B P 8 GA MO SV4PXSM6001 O O AI PI (ISTC3700)

Accumulator A to RCS Isolation Valve (B6)

SV4PXSPLV027B 3 N B P 8 GA MO SV4PXSM6001 O O AI PI (ISTC3700)

Accumulator B to RCS Isolation Valve (B3)

SV4PXSPLV028A 1 N AC A 8 CK SA SV4PXSM6001 C O/C NA CKO (B6) CKC Accumulator A outlet to RCS Check LT SV4PXSPLV028B 1 N AC A 8 CK SA SV4PXSM6001 C O/C NA CKO (B3) CKC Accumulator B outlet to RCS Check LT SV4PXSPLV029A 1 N AC A 8 CK SA SV4PXSM6001 C O/C NA CKO (B6) CKC Accumulator A outlet to RCS Check LT SV4PXSPLV029B 1 N AC A 8 CK SA SV4PXSM6001 C O/C NA CKO (B4) CKC Accumulator B outlet to RCS Check LT SV4PXSPLV042 2 N A A 1 GL AO SV4PXSM6001 O C C PI (ISTC3700)

(D1) STC FST High Pressure Nitrogen to Containment Isolation Valve LTApp. J SV4PXSPLV043 2 N AC A 1 CK SA SV4PXSM6001 C O/C NA CKOP Accommodate thermal expansion (D2) CKC High Pressure Nitrogen to Containment IC Check Valve LTApp. J SV4PXSPLV044 N N C A 1 RV SA SV4PXSM6001 C O NA VE(I7150(a))

(D2) RVT(I7150(b)) Verify Vendor setpoint High Pressure Nitrogen to Containment Penetration Thermal Relief Valve RVT(I7150(c)) Leak tightness (from Vendor test)

SV4PXSPLV101 1 N B P 14 GA MO SV4PXSM6002 O O AI PI (ISTC3700)

RCS to PRHR Heat Exchanger Isolation Valve 79 Southern Nuclear Version 3.0

System: PXS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4PXSPLV108A 1 N B A 14 BA AO SV4PXSM6002 C O O PI (ISTC3700)

(F1) STO PRHR Heat Exchanger Outlet Valve to RCS A FST SV4PXSPLV108B 1 N B A 14 BA AO SV4PXSM6002 C O O PI (ISTC3700)

(E1) STO PRHR Heat Exchanger Outlet Valve to RCS B FST SV4PXSPLV109 1 N B P 14 GA MA SV4PXSM6002 LO O AI PI (ISTC3700)

PRHR HX/RCS Return Isol Valve (F1)

SV4PXSPLV117A 3 N B P 8 GA MO SV4PXSM6002 O O AI PI (ISTC3700)

Containment Recirculation Sump A to RCS Isolation Valve (E7)

SV4PXSPLV117B 3 N B P 8 GA MO SV4PXSM6002 O O AI PI (ISTC3700)

Containment Recirculation Sump B to RCS Isolation Valve (E5)

SV4PXSPLV118A 3 N D A 8 SQ SQ SV4PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump A to RCS Actuation Squib Valve (E7) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4PXSPLV118B 3 N D A 8 SQ SQ SV4PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump B to RCS Actuation Squib Valve (E5) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4PXSPLV119A 3 N C A 8 CK SA SV4PXSM6002 C O/C NA PI (ISTC3700)

(D7) CKO Containment Recirc. Sump A outlet to RCS Check CKC SV4PXSPLV119B 3 N C A 8 CK SA SV4PXSM6002 C O/C NA PI (ISTC3700)

(D5) CKO Containment Recirc. Sump B outlet to RCS Check CKC SV4PXSPLV120A 3 N D A 8 SQ SQ SV4PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump A to RCS Actuation Squib Valve (D7) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4PXSPLV120B 3 N D A 8 SQ SQ SV4PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump B to RCS Actuation Squib Valve (D5) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4PXSPLV121A 3 N B P 8 GA MO SV4PXSM6002 O O AI PI (ISTC3700)

IRWST/Recirc Sump to RCS A Isolation Valve (D7)

SV4PXSPLV121B 3 N B P 8 GA MO SV4PXSM6002 O O AI PI (ISTC3700)

IRWST/Recirc Sump to RCS B Isolation Valve (D5)

SV4PXSPLV122A 1 N C A 8 CK SA SV4PXSM6002 C O/C NA PI (ISTC3700)

(C7) CKO IRWST/Recirc Sump to RCS A outlet to RCS Check CKC SV4PXSPLV122B 1 N C A 8 CK SA SV4PXSM6002 C O/C NA PI (ISTC3700)

(C5) CKO IRWST/Recirc Sump to RCS B outlet to RCS Check CKC 80 Southern Nuclear Version 3.0

System: PXS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4PXSPLV123A 1 N D A 8 SQ SQ SV4PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump A to RCS Actuation Squib Valve (C7) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4PXSPLV123B 1 N D A 8 SQ SQ SV4PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump B to RCS Actuation Squib Valve (D5) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4PXSPLV124A 1 N C A 8 CK SA SV4PXSM6002 C O/C NA PI (ISTC3700)

(C7) CKO IRWST/Recirc Sump to RCS A outlet to RCS Check CKC SV4PXSPLV124B 1 N C A 8 CK SA SV4PXSM6002 C O/C NA PI (ISTC3700)

(C5) CKO IRWST/Recirc Sump to RCS B outlet to RCS Check CKC SV4PXSPLV125A 1 N D A 8 SQ SQ SV4PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump A to RCS Actuation Squib Valve (C7) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4PXSPLV125B 1 N D A 8 SQ SQ SV4PXSM6002 C O NA Circuit(ISTC3100(d)(1))

Containment Recirc. Sump B to RCS Actuation Squib Valve (D5) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4PXSPLV130A 3 N B A 2 BA AO SV4PXSM6002 O C C PI (ISTC3700)

(H7) STC Containment Condensation Collection to Containment Sump Isolation Valve A FST SV4PXSPLV130B 3 N B A 2 BA AO SV4PXSM6002 O C C PI (ISTC3700)

(H7) STC Containment Condensation Collection to Containment Sump Isolation Valve B FST SV4PXSPLV208A 2 N A P .375 GL MA SV4PXSM6003 LC C C LTApp. J RNS Suction Leak Test Valve (D3)

SV4PXSPLV230A 2 N B P 1 GL AO SV4PXSM6003 C C C PI (ISTC3700)

Core Makeup Tank A Fill Isolation (F6)

SV4PXSPLV230B 2 N B P 1 GL AO SV4PXSM6003 C C C PI (ISTC3700)

Core Makeup Tank B Fill Isolation (G6)

SV4PXSPLV231A 2 N C A 1 CK SA SV4PXSM6003 C C C CKOP Accommodate thermal expansion Core Makeup Tank A Fill Check (F7) CKC SV4PXSPLV231B 2 N C A 1 CK SA SV4PXSM6003 C C C CKOP Accommodate thermal expansion Core Makeup Tank B Fill Check (G7) CKC SV4PXSPLV232A 3 N B P 1 GL AO SV4PXSM6003 C C C PI (ISTC3700)

Accumulator B Fill/Drain Isolation (E6)

SV4PXSPLV232B 3 N B P 1 GL AO SV4PXSM6003 C C C PI (ISTC3700)

Accumulator B Fill/Drain Isolation (G6) 81 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: RCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4RCSPLV001A 1 N B A 4 GL MO SV4RCSM6002 C O AI PI (III3300)

(G5) STO III3100 ADS Stage 1 Control Valve III3300 SV4RCSPLV001B 1 N B A 4 GL MO SV4RCSM6002 C O AI PI (III3300)

(E5) STO III3100 ADS Stage 1 Control Valve III3300 SV4RCSPLV002A 1 N B A 8 GL MO SV4RCSM6002 C O AI PI (III3300)

(G5) STO III3100 ADS Stage 2 Control Valve III3300 SV4RCSPLV002B 1 N B A 8 GL MO SV4RCSM6002 C O AI PI (III3300)

(E5) STO III3100 ADS Stage 2 Control Valve III3300 SV4RCSPLV003A 1 N B A 8 GL MO SV4RCSM6002 C O AI PI (III3300)

(H5) STO III3100 ADS Stage 3 Control Valve III3300 SV4RCSPLV003B 1 N B A 8 GL MO SV4RCSM6002 C O AI PI (III3300)

(F5) STO III3100 ADS Stage 3 Control Valve III3300 SV4RCSPLV004A 1 N D A 14 SQ SQ SV4RCSM6001 C O NA Circuit(ISTC3100(d)(1))

ADS Stage 4 Valve (G6) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4RCSPLV004B 1 N D A 14 SQ SQ SV4RCSM6001 C O NA Circuit(ISTC3100(d)(1))

ADS Stage 4 Valve (F3) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 82 Southern Nuclear Version 3.0

System: RCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4RCSPLV004C 1 N D A 14 SQ SQ SV4RCSM6001 C O NA Circuit(ISTC3100(d)(1))

ADS Stage 4 Valve (F6) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4RCSPLV004D 1 N D A 14 SQ SQ SV4RCSM6001 C O NA Circuit(ISTC3100(d)(1))

ADS Stage 4 Valve (F3) Charge(ISTC3100(d)(2)) Alternative VEGP 3&4PSTAlt01 SV4RCSPLV005A 1 N C A 6 RV SA SV4RCSM6002 C O/C NA PI (I7110(c)/7310(f)) From Vendor test (H7) RVT(I7110(b)) Verify Vendor setpoint RVT(I7110(d)) Leak tightness per Vendor test VE(I7110(a))

RVT(I7210) Setpoint verification (due 6m prior to Initial Pressurizer Safety Valve Criticality) Alternative VEGP 3&4PSTAlt02 SV4RCSPLV005B 1 N C A 6 RV SA SV4RCSM6002 C O/C NA PI (I7110(c)/7310(f)) From Vendor test (F6) RVT(I7110(b)) Verify Vendor setpoint RVT(I7110(d)) Leak tightness per Vendor test VE(I7110(a))

RVT(I7210) Setpoint verification (due 6m prior to Initial Pressurizer Safety Valve Criticality) Alternative VEGP 3&4PSTAlt02 SV4RCSPLV010A 3 N C A 1 VB SA SV4RCSM6002 C O NA VE(I7170)

(G4) RVT(I7270(a)) Actuation to verify open/close ADS Header Vacuum Breaker RVT(I7270(b)) Leak tightness SV4RCSPLV010B 3 N C A 1 VB SA SV4RCSM6002 C O NA VE(I7170)

(E4) RVT(I7270(a)) Actuation to verify open/close ADS Header Vacuum Breaker RVT(I7270(b)) Leak tightness SV4RCSPLV011A 1 N B A 4 GA MO SV4RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (G5) STO III3100 ADS Stage 1 Isolation Valve III3300 SV4RCSPLV011B 1 N B A 4 GA MO SV4RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (E5) STO III3100 ADS Stage 1 Isolation Valve III3300 SV4RCSPLV012A 1 N B A 8 GA MO SV4RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (G5) STO III3100 ADS Stage 2 Isolation Valve III3300 83 Southern Nuclear Version 3.0

System: RCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4RCSPLV012B 1 N B A 8 GA MO SV4RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (E5) STO III3100 ADS Stage 2 Isolation Valve III3300 SV4RCSPLV013A 1 N B A 8 GA MO SV4RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (H5) STO III3100 ADS Stage 3 Isolation Valve III3300 SV4RCSPLV013B 1 N B A 8 GA MO SV4RCSM6002 C O/C AI PI (III3300) Closed safety function is passive (F5) STO III3100 ADS Stage 3 Isolation Valve III3300 SV4RCSPLV014A 1 N B P 14 GA MO SV4RCSM6001 O O AI PI (ISTC3700)

ADS Stage 4 Block Valve (G6)

SV4RCSPLV014B 1 N B P 14 GA MO SV4RCSM6001 O O AI PI (ISTC3700)

ADS Stage 4 Block Valve (F3)

SV4RCSPLV014C 1 N B P 14 GA MO SV4RCSM6001 O O AI PI (ISTC3700)

ADS Stage 4 Block Valve (F6)

SV4RCSPLV014D 1 N B P 14 GA MO SV4RCSM6001 O O AI PI (ISTC3700)

ADS Stage 4 Block Valve (F3)

SV4RCSPLV150A 1 N B A 1 GL SO SV4RCSM6001 C O/C C PI (ISTC3700)

(D4) STO STC FST Reactor Head Vent Valve RVT Thermal Relief function SV4RCSPLV150B 1 N B A 1 GL SO SV4RCSM6001 C O/C C PI (ISTC3700)

(D4) STO STC FST Reactor Head Vent Valve RVT Thermal Relief function SV4RCSPLV150C 1 N B A 1 GL SO SV4RCSM6001 C O/C C PI (ISTC3700)

(D4) STO STC Reactor Head Vent Valve FST 84 Southern Nuclear Version 3.0

System: RCS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4RCSPLV150D 1 N B A 1 GL SO SV4RCSM6001 C O/C C PI (ISTC3700)

(D4) STO STC Reactor Head Vent Valve FST SV4RCSPLV233 3 N B P 2 GL MA SV4RCSM6002 O O AI PI (ISTC3700) Open only indication RV Head Vent to IRWST Isolation Valve (H3)

SV4RCSPYK03 3 N D A 10 RD SA SV4RCSM6002 C O NA VE(I7160/7260)

Pressurizer Relief Valve Discharge Line Rupture Disc (H8)

SV4RCSPYK04 3 N D A 10 RD SA SV4RCSM6002 C O NA VE(I7160/7260)

Pressurizer Relief Valve Discharge Line Rupture Disc (F7) 85 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: RNS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4RNSPLV001A 1 N A A 10 GA MO SV4RNSM6001 C C AI PI (III3300)

(F2) STC III3100 III3300 RNS Suction from RCS Inner Isolation Valve LT SV4RNSPLV001B 1 N A A 10 GA MO SV4RNSM6001 C C AI PI (III3300)

(D2) STC III3100 III3300 RNS Suction from RCS Inner Isolation Valve LT SV4RNSPLV002A 1 N A A 10 GA MO SV4RNSM6001 C C AI PI (III3300)

(F2) STC III3100 III3300 LT RNS Suction from RCS Outer Isolation /IC Containment Isolation Valve LTApp. J SV4RNSPLV002B 1 N A A 10 GA MO SV4RNSM6001 C C AI PI (III3300)

(D2) STC III3100 III3300 LT RNS Suction from RCS Outer Isolation /IC Containment Isolation Valve LTApp. J SV4RNSPLV003A 2 N C A 1 CK SA SV4RNSM6001 C O NA CKOP Accommodate thermal expansion RNS PIV Thermal Relief Valve (G2) CKC SV4RNSPLV003B 2 N C A 1 CK SA SV4RNSM6001 C O NA CKOP Accommodate thermal expansion RNS PIV Thermal Relief Valve (D2) CKC SV4RNSPLV011 2 N A A 8 GA MO SV4RNSM6001 C C AI PI (III3300)

(F7) STC III3100 III3300 RNS Discharge Header to Containment OC Containment Isolation Valve LTApp. J 86 Southern Nuclear Version 3.0

System: RNS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4RNSPLV012 2 N A A 1 GL MA SV4RNSM6001 C C/O AI ETM PostAccident Long Term RCS Makeup & Containment Isolation Valve (G7) LT App. J SV4RNSPLV013 2 N AC A 8 CK SA SV4RNSM6001 C C/O NA CKO Accommodate thermal expansion (F7) CKC RNS to Containment IC Containment Isolation Valve LT App. J SV4RNSPLV015A 1 N AC A 6 CK SA SV4RNSM6001 C C/O NA CKO Accommodate thermal expansion (F8) CKC RNS to DVI Stop Check Valve LT SV4RNSPLV015B 1 N AC A 6 CK SA SV4RNSM6001 C C/O NA CKO Accommodate thermal expansion (F8) CKC RNS to DVI Stop Check Valve LT SV4RNSPLV017A 1 N AC A 6 CK SA SV4RNSM6001 C C/O NA CKO Accommodate thermal expansion (F8) CKC RNS to DVI Check Valve LT SV4RNSPLV017B 1 N AC A 6 CK SA SV4RNSM6001 C C/O NA CKO Accommodate thermal expansion (F8) CKC RNS to DVI Check Valve LT SV4RNSPLV020 2 N AC A 1 RV SA SV4RNSM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (G2) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

RNS Suction Relief Valve LTApp. J SV4RNSPLV021 2 N AC A 3 RV SA SV4RNSM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (G2) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

RNS Suction Relief Valve LTApp. J SV4RNSPLV022 2 N A A 10 GA MO SV4RNSM6001 C C AI PI (III3300)

(F3) STC III3100 III3300 RNS Suction from RCS OC Containment Isolation Valve LTApp. J SV4RNSPLV023 2 N A A 10 GA MO SV4RNSM6001 C C AI PI (III3300)

(E3) STC III3100 III3300 RNS Suction from IRWST/IC Containment Isolation Valve LTApp. J 87 Southern Nuclear Version 3.0

System: RNS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4RNSPLV061 2 N A A 3 GL AO SV4RNSM6001 C C C PI (ISTC3700)

(G3) STC FST CVS return to RNS Suction/IC Containment Isolation Valve LTApp. J 88 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: SDS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4SDSPLV001 3 N B A 3 BU MO SV4SDSM6001 O C AI PI (III3300)

(E5) STC III3100 MCR SDS (Vent) Isolation Valve III3300 SV4SDSPLV002 3 N B A 3 BU MO SV4SDSM6001 O C AI PI (III3300)

(E5) STC III3100 MCR SDS (Vent) Isolation Valve III3300 89 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: SFS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4SFSPLV031 3 N B P 6 BU MA SV4SFSM6001 LO O AI PI (ISTC3700)

Refueling Cavity Drain to S/G 2 Compartment Isolation Valve (F7)

SV4SFSPLV033 3 N B P 2 PL MA SV4SFSM6001 LC C AI PI (ISTC3700)

Refueling Cavity Drain to Containment Sump Isolation Valve (E7)

SV4SFSPLV034 2 N A A 6 BU MO SV4SFSM6001 C C AI PI (III3300)

(D6) STC III3100 III3300 Refueling Cavity/IRWST to SFS IC Containment Iso Valve LTApp. J SV4SFSPLV035 2 N A A 6 BU MO SV4SFSM6001 C C AI PI (III3300)

(D5) STC III3100 III3300 Refueling Cavity/IRWST to SFS OC Containment Iso Valve LTApp. J SV4SFSPLV037 2 N AC A 4 CK SA SV4SFSM6001 C C/O NA CKC (B6) CKOP Accommodate thermal expansion SFS to Refueling Cavity/IRWST IC Containment Iso Valve LTApp. J SV4SFSPLV038 2 N A A 4 BU MO SV4SFSM6001 C C AI PI (III3300)

(B5) STC III3100 III3300 SFS to Refueling Cavity/IRWST OC Containment Iso Valve LTApp. J SV4SFSPLV041 3 N B A 6 BU MA SV3SFSM6001 LC C AI ETM SFS Cask Loading Pit Suction Isolation Valve (F1)

SV4SFSPLV066 3 N B A 2 BA MA SV4SFSM6001 LC C/O AI ETM Spent Fuel Pool Boiloff Makeup Isolation Valve (F3)

SV4SFSPLV067 2 N AC A 1 RV SA SV4SFSM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (E6) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Refueling Cavity/IRWST to SFS Penetration Relief Valve LTApp. J 90 Southern Nuclear Version 3.0

System: SFS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4SFSPLV068 3 N B A 4 BU MA SV3SFSM6001 LO O AI ETM SFS Cask Washdown Pit Drain Isolation Valve (F2)

SV4SFSPLV071 3 N C A 6 CK SA SV4SFSM6001 C O/C NA CKO Refueling Cavity/IRWST to SFS Penetration Relief Valve (E6) CKC SV4SFSPLV072 3 N C A 6 CK SA SV4SFSM6001 C O/C NA CKO Refueling Cavity/IRWST to SFS Penetration Relief Valve (E6) CKC SV4SFSPLV075 3 N B P 20 BU MA SV4SFSM6001 LO O AI PI (ISTC3700)

SFS Reactor Cavity PostAccident Containment Floodup Valve (G7) 91 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4SGSPLV027A 2 N B A 12 GL MO SV4SGSM6001 O C AI PI (III3300)

(G2) STC III3100 SG 1 PORV Isolation valve III3300 SV4SGSPLV027B 2 N B A 12 GL MO SV4SGSM6002 O C AI PI (III3300)

(G2) STC III3100 SG 2 PORV Isolation valve III3300 SV4SGSPLV030A 2 N C A 8X10 RV SA SV4SGSM6001 C O/C NA VE(I7150(a))

(G4/5) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV030B 2 N C A 8X10 RV SA SV4SGSM6002 C O/C NA VE(I7150(a))

(G4/5) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV031A 2 N C A 8X10 RV SA SV4SGSM6001 C O/C NA VE(I7150(a))

(G4) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test 92 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4SGSPLV031B 2 N C A 8X10 RV SA SV4SGSM6002 C O/C NA VE(I7150(a))

(G4) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV032A 2 N C A 8X10 RV SA SV4SGSM6001 C O/C NA VE(I7150(a))

(G4) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV032B 2 N C A 8X10 RV SA SV4SGSM6002 C O/C NA VE(I7150(a))

(G4) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV033A 2 N C A 8X10 RV SA SV4SGSM6001 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV033B 2 N C A 8X10 RV SA SV4SGSM6002 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test 93 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4SGSPLV034A 2 N C A 8X10 RV SA SV4SGSM6001 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV034B 2 N C A 8X10 RV SA SV4SGSM6002 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV035A 2 N C A 8X10 RV SA SV4SGSM6001 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 1 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV035B 2 N C A 8X10 RV SA SV4SGSM6002 C O/C NA VE(I7150(a))

(G3) RVT(I7150(b)) Verify Vendor setpoint RVT(I7150(c)) Leak tightness per Vendor test RVT(I7250(a)(1)) Setpoint verification (due 6m prior to Initial Criticality)

SG 2 Safety Valve RVT(I7250(a)(2)) Leak tightness verification after set test SV4SGSPLV036A 2 N B A 2 GL AO SV4SGSM6001 O C C PI (ISTC3700)

(G3) STC SG1 Steam Line Drain Isolation FST SV4SGSPLV036B 2 N B A 2 GL AO SV4SGSM6002 O C C PI (ISTC3700)

(G3) STC SG2 Steam Line Drain Isolation FST 94 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4SGSPLV040A 2 N B A 38 GA PH SV4SGSM6001 O C C PI (ISTC3700)

(G1) STC SG 1 Main Steam Isolation Valve FST SV4SGSPLV040B 2 N B A 38 GA PH SV4SGSM6002 O C C PI (ISTC3700)

(G1) STC SG 2 Main Steam Isolation Valve FST SV4SGSPLV057A 2 N B A 20 GA PH SV4SGSM6001 O C C PI (ISTC3700)

(E4) STC SG 1 Main Feedwater Isolation Valve FST SV4SGSPLV057B 2 N B A 20 GA PH SV4SGSM6002 O C C PI (ISTC3700)

(E4) STC SG 2 Main Feedwater Isolation Valve FST SV4SGSPL058A 2 N C A 20 CK SA SV4SGSM6001 O C/O NA CKOP Accommodate thermal expansion SG1 Main Feed Check Valve (E5) CKC SV4SGSPL058B 2 N C A 20 CK SA SV4SGSM6002 O C/O NA CKOP Accommodate thermal expansion SG2 Main Feed Check Valve (E5) CKC SV4SGSPLV067A 2 N B A 6 GA MO SV4SGSM6001 O C AI PI (III3300)

(D5) STC III3100 SG 1 Startup Feedwater Isolation Valve III3300 SV4SGSPLV067B 2 N B A 6 GA MO SV4SGSM6002 O C AI PI (III3300)

(D5) STC III3100 SG 2 Startup Feedwater Isolation Valve III3300 SV4SGSPLV074A 2 N B A 4 GL AO SV4SGSM6001 O C C PI (ISTC3700)

(C5) STC SG 1 Blowdown Isolation Valve FST SV4SGSPLV074B 2 N B A 4 GL AO SV4SGSM6002 O C C PI (ISTC3700)

(C5) STC SG 2 Blowdown Isolation Valve FST SV4SGSPLV075A 3 N B A 4 GL AO SV4SGSM6001 O C C PI (ISTC3700)

(C5) STC SG 1 Blowdown Isolation Valve Secondoff FST 95 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4SGSPLV075B 3 N B A 4 GL AO SV4SGSM6002 O C C PI (ISTC3700)

(C5) STC SG 2 Blowdown Isolation Valve Secondoff FST SV4SGSPLV086A 3 N B A 2 GL AO SV4SGSM6001 C C C PI (ISTC3700)

(F3) STC SG1 Steam Line Drain Level Control FST SV4SGSPLV086B 3 N B A 2 GL AO SV4SGSM6002 C C C PI (ISTC3700)

(F3) STC SG2 Steam Line Drain Level Control FST SV4SGSPLV233A 3 N B A 12 GL AO SV4SGSM6001 C C C PI (ISTC3700)

(H2) STC SG 1 Power Operated Relief Valve (PORV) FST SV4SGSPLV233B 3 N B A 12 GL AO SV4SGSM6002 C C C PI (ISTC3700)

(H2) STC SG 2 Power Operated Relief Valve (PORV) FST SV4SGSPLV240A 2 N B A 3 GL AO SV4SGSM6001 C C C PI (ISTC3700)

(G1) STC SG 1 MSIV Bypass Valve FST SV4SGSPLV240B 2 N B A 3 GL AO SV4SGSM6002 C C C PI (ISTC3700)

(G1) STC SG 2 MSIV Bypass Valve FST SV4SGSPLV250A 3 N B A 20 GL AO SV4SGSM6001 O C C PI (ISTC3700)

(E2/3) STC SG 1 Feedwater Control Valve FST SV4SGSPLV250B 3 N B A 20 GL AO SV4SGSM6002 O C C PI (ISTC3700)

(E2/3) STC SG 2 Feedwater Control Valve FST SV4SGSPLV255A 3 N B A 6 GL AO SV4SGSM6001 C C C PI (ISTC3700)

(D4) STC SG 1 Startup Feedwater Control Valve FST SV4SGSPLV255B 3 N B A 6 GL AO SV4SGSM6002 C C C PI (ISTC3700)

(D4) STC SG 2 Startup Feedwater Control Valve FST 96 Southern Nuclear Version 3.0

System: SGS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4SGSPL256A 2 N C A 6 CK SA SV4SGSM6001 C O NA CKOP Accommodate thermal expansion SG1 Startup Feedwater Check Valve (D4) CKC SV4SGSPL256B 2 N C A 6 CK SA SV4SGSM6002 C O NA CKOP Accommodate thermal expansion SG2 Startup Feedwater Check Valve (D4) CKC SV4SGSPLV257A 3 N C A 1 RV SA SV4SGSM6001 C O NA RVT(I7150(b)) Verify Vendor setpoint (E4) RVT(I7150(c)) Leak tightness per Vendor test Main Feedwater Thermal Relief VE(I7150(a))

SV4SGSPLV257B 3 N C A 1 RV SA SV4SGSM6002 C O NA RVT(I7150(b)) Verify Vendor setpoint (E4) RVT(I7150(c)) Leak tightness per Vendor test Main Feedwater Thermal Relief VE(I7150(a))

SV4SGSPLV258A 3 N C A 1 RV SA SV4SGSM6001 C O NA RVT(I7150(b)) Verify Vendor setpoint (D4) RVT(I7150(c)) Leak tightness per Vendor test Startup Feedwater Thermal Relief VE(I7150(a))

SV4SGSPLV258B 3 N C A 1 RV SA SV4SGSM6002 C O NA RVT(I7150(b)) Verify Vendor setpoint (D4) RVT(I7150(c)) Leak tightness per Vendor test Startup Feedwater Thermal Relief VE(I7150(a))

97 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: VBS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4VBSPLV186 3 N B A 28 BU MO SV4VBSM6007 O C AI PI (III3300)

(F6) STC III3100 MCR Supply Air Isolation Valve III3300 SV4VBSPLV187 3 N B A 28 BU MO SV4VBSM6007 O C AI PI (III3300)

(F6) STC III3100 MCR Supply Air Isolation Valve III3300 SV4VBSPLV188 3 N B A 28 BU MO SV4VBSM6007 O C AI PI (III3300)

(C7) STC III3100 MCR Return Air Isolation Valve III3300 SV4VBSPLV189 3 N B A 28 BU MO SV4VBSM6007 O C AI PI (III3300)

(C6) STC III3100 MCR Return Air Isolation Valve III3300 SV4VBSPLV190 3 N B A 6 BU MO SV4VBSM6007 O C AI PI (III3300)

(C3) STC III3100 MCR Toilet Exhaust Isolation Valve III3300 SV4VBSPLV191 3 N B A 6 BU MO SV4VBSM6007 O C AI PI (III3300)

(C3) STC III3100 MCR Toilet Exhaust Isolation Valve III3300 98 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: VES Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4VESPLV001 3 N B A 1 GL MA SV4VESM6002 C O/C AI ETM Air Delivery Isolation Valve (D5)

SV4VESPLV005A 3 N B A 1 GL SO SV4VESM6002 C O O PI (ISTC3700)

(F5) STO Air Delivery Isolation Valve A FST SV4VESPLV005B 3 N B A 1 GL SO SV4VESM6002 C O O PI (ISTC3700)

(E5) STO Air Delivery Isolation Valve B FST SV4VESPLV018 3 N B A 1 GL MA SV4VESM6002 C O/C AI ETM Temporary InstrumentationIsolation Valve (F5)

SV4VESPLV019 3 N B A 1 GL MA SV4VESM6002 C O/C AI ETM Temporary InstrumentationIsolation Valve (D5)

SV4VESPLV022A 3 N B A 4 BU AO SV4VESM6002 C O O PI (ISTC3700)

(C2) STO Pressure Relief Isolation Valve A FST SV4VESPLV022B 3 N B A 4 BU AO SV4VESM6002 C O O PI (ISTC3700)

(C2) STO Pressure Relief Isolation Valve B FST SV4VESPLV040A 3 N C A 1 RV SA SV4VESM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (H4) RVT(I7150(c)) Leak tightness per Vendor test Air Tank Safety Relief Valve A VE(I7150(a))

SV4VESPLV040B 3 N C A 1 RV SA SV4VESM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (F4) RVT(I7150(c)) Leak tightness per Vendor test Air Tank Safety Relief Valve B VE(I7150(a))

SV4VESPLV040C 3 N C A 1 RV SA SV4VESM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (E4) RVT(I7150(c)) Leak tightness per Vendor test Air Tank Safety Relief Valve C VE(I7150(a))

99 Southern Nuclear Version 3.0

System: VES Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4VESPLV040D 3 N C A 1 RV SA SV4VESM6001 C O/C NA RVT(I7150(b)) Verify Vendor setpoint (C4) RVT(I7150(c)) Leak tightness per Vendor test Air Tank Safety Relief Valve D VE(I7150(a))

SV4VESPLV044 3 N B A 1 GL MA SV4VESM6002 LO O/C AI ETM Eductor Flow Path Isolation Valve (F4)

SV4VESPLV045 3 N B A 1 GL MA SV4VESM6002 LO O/C AI ETM Eductor Flow Path Isolation Valve (E3)

SV4VESPLV046 3 N B A 1 GL MA SV4VESM6002 C O/C AI ETM Eductor Bypass Isolation Valve (D3) 100 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: VFS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4VFSPLV003 2 N A A 16 BU AO SV4VFSM6001 C C C PI (ISTC3700)

(B4) STC FST Containment Purge Inlet Containment Isol ORC LTApp. J SV4VFSPLV004 2 N A A 16 BU AO SV4VFSM6001 C C C PI (ISTC3700)

(B3) STC FST Containment Purge Inlet Containment Isol IRC LTApp. J SV4VFSPLV009 2 N A A 16 BU AO SV4VFSM6001 C C C PI (ISTC3700)

(D8) STC FST Containment Purge Discharge Containment Isol IRC LTApp. J SV4VFSPLV010 2 N A A 16 BU AO SV4VFSM6001 C C C PI (ISTC3700)

(D7) STC FST Containment Purge Discharge Containment Isol ORC LTApp. J SV4VFSPLV800A 2 N A A 6 BU MO SV4VFSM6001 C O/C AI PI (III3300)

(E7) STC STO III3100 III3300 Containment Vacuum Relief Isolation Valve A ORC LTApp. J SV4VFSPLV800B 2 N A A 6 BU MO SV4VFSM6001 C O/C AI PI (III3300)

(E7) STC STO III3100 III3300 Containment Vacuum Relief Isolation Valve B ORC LTApp. J SV4VFSPLV803A 2 N AC A 6 VB SA SV4VFSM6001 C O/C NA VE(I7170) Vacuum Relief (E7) RVT(I7270(a)) Actuation to verify open/close Containment Vacuum Relief Valve A - IRC LTApp. J Also meets LT requirements of I7270(b) 101 Southern Nuclear Version 3.0

System: VFS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4VFSPLV803B 2 N AC A 6 VB SA SV4VFSM6001 C O/C NA VE(I7170) Vacuum Relief (E7) RVT(I7270(a)) Actuation to verify open/close Containment Vacuum Relief Valve B - IRC LTApp. J Also meets LT requirements of I7270(b) 102 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: VWS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4VWSPLV053 3 N C A 2 RV SA SV4VWSM6003 C O NA RVT(I7150(b)) Verify Vendor setpoint (B6) RVT(I7150(c)) Leak tightness per Vendor test Ctmt Cooling Unit Supply Hdr Relief VE(I7150(a))

SV4VWSPLV057 3 N C A 2 RV SA SV4VWSM6003 C O NA RVT(I7150(b)) Verify Vendor setpoint (H4) RVT(I7150(c)) Leak tightness per Vendor test Ctmt Cooling Unit Return Hdr Relief VE(I7150(a))

SV4VWSPLV058 2 N A A 8 BU AO SV4VWSM6003 O C C PI (ISTC3700)

(B6) STC FST Chilled Water Inlet Containment Isolation Valve LT App. J SV4VWSPLV062 2 N AC A 8 CK SA SV4VWSM6003 O C/O NA CKC (B6) CKOP Accommodate thermal expansion Fan Coolers Supply IC Isol Check Valve LT App. J SV4VWSPLV080 2 N AC A 1 RV SA SV4VWSM6003 C C/O NA RVT(I7150(b)) Verify Vendor setpoint (H4) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Ctmt Cooling Unit Return CIV Relief LT App. J SV4VWSPLV082 2 N A A 8 BU AO SV4VWSM6003 O C C PI (ISTC3700)

(G3) STC FST Chilled Water Outlet Containment Isolation Valve LT App. J SV4VWSPLV086 2 N A A 8 BU AO SV4VWSM6003 O C C PI (ISTC3700)

(G3) STC FST Chilled Water Outlet Containment Isolation Valve LT App. J 103 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Valve Table Unit 4 System: WLS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4WLSPLV055 2 N A A 2 PL AO SV4WLSM6001 C C C PI (ISTC3700)

(C4) STC FST Containment Sump Discharge CIV - IRC LTApp. J SV4WLSPLV057 2 N A A 2 PL AO SV4WLSM6001 C C C PI (ISTC3700)

(C3) STC FST Containment Sump Discharge CIV - ORC LTApp. J SV4WLSPLV058 2 N AC A 1 RV SA SV4WLSM6001 C C/O NA RVT(I7150(b)) Verify Vendor setpoint (C4) RVT(I7150(c)) Leak tightness per Vendor test VE(I7150(a))

Containment Sump Discharge Penetration Thermal Relief LTApp. J SV4WLSPLV067 2 N A A 1 GL AO SV4WLSM6001 C C C PI (ISTC3700)

(E3) STC FST RCDT Gas Outlet CIV IRC LTApp. J SV4WLSPLV068 2 N A A 1 GL AO SV4WLSM6001 C C C PI (ISTC3700)

(E3) STC FST RCDT Gas Outlet CIV ORC LTApp. J SV4WLSPLV071A 3 N C A 4 CK SA SV4WLSM6001 C O/C NA CKO CVS Compt Floor Drain Check (C8) CKC SV4WLSPLV071B 3 N C A 4 CK SA SV4WLSM6001 C O/C NA CKO PXS Compt A Floor Drain Check (F8) CKC SV4WLSPLV071C 3 N C A 4 CK SA SV4WLSM6001 C O/C NA CKO PXS Compt B Floor Drain Check (F8) CKC SV4WLSPLV072A 3 N C A 4 CK SA SV4WLSM6001 C O/C NA CKO CVS Compt Floor Drain Check (C7) CKC SV4WLSPLV072B 3 N C A 4 CK SA SV4WLSM6001 C O/C NA CKO PXS Compt A Floor Drain Check (F8) CKC 104 Southern Nuclear Version 3.0

System: WLS Valve ID Valve Actuator Drawing Position Required Description Class Aug. Cat. A/P Size Type Type & Coord. Normal Safety FailSafe Test Alt/CC Comments/Notes SV4WLSPLV072C 3 N C A 4 CK SA SV4WLSM6001 C O/C NA CKO PXS Compt B Floor Drain Check (F8) CKC 105 Southern Nuclear Version 3.0

9.0 PRESERVICE TESTING OF DYNAMIC RESTRAINTS 9.1 GENERAL All Dynamic Restraints listed in the Tables of Section 11.0 and 12.0 will receive the following:

a) A Visual examination meeting the requirements of ISTD4110; b) Testing per ISTD5120. Note, this testing may have been done at the manufacturer facility as allowed by ISTD5110; c) Thermal movement examinations to meet the requirements of ISTD4130.

d) Corrective actions from failures of visual examinations or tests will be performed in accordance with ISTD4140 or ISTD5130, as appropriate.

9.2 SCHEDULE a) Testing will be performed prior to installation in the system.

b) Initial Visual Examinations will be performed prior to Hot Functional testing.

c) Visual reexaminations, if required per ISTD4120, will be performed in conjunction with Initial Thermal Movement examinations.

d) Initial Thermal Movement examinations will be performed during Precore Hot Functional testing. Any subsequent Thermal Movement examinations will be done during PostCore Hot Functional testing.

106 Southern Nuclear Version 3.0

10.0 DYNAMIC RESTRAINTS NOTES None 107 Southern Nuclear Version 3.0

11.0 VEGP3 DYNAMIC RESTRAINTS TABLES 108 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 3 System: CVS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV3CVSPH11Y02621 3 H SV3CVSPLW171/D4 SV3CVSPH11Y02622 3 H SV3CVSPLW171/D4 SV3CVSPH11Y0268 1 H SV3CVSPLW188/C4 SV3CVSPH11Y2040 1 H SV3CVSPLW171/C5 SV3CVSPH11Y2223 1 H SV3CVSPLW171/C5 SV3CVSPH11Y2224 1 H SV3CVSPLW171/C4 SV3CVSPH11Y2227 3 H SV3CVSPLW171/C3 SV3CVSPH11Y2229 1 H SV3CVSPLW182/C6 SV3CVSPH11Y2263 N H SV3CVSPLW091/C4 SV3CVSPH11Y2265 N H SV3CVSPLW091/B6 .

SV3CVSPH11Y2266 N H SV3CVSPLW091/B6 SV3CVSPH11Y7074 3 H SV3CVSPLW187/B5 109 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 3 System: PXS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV3PXSPH11Y0020 1 H SV3PXSPLW01Q/C5 SV3PXSPH11Y0578 3 H SV3PXSPLW01Z/C5 SV3PXSPH11Y2052 3 H SV3PXSPLW02E/C5/6 SV3PXSPH11Y2057 3 H SV3PXSPLW015/C5 SV3PXSPH11Y2059 3 H SV3PXSPLW01H/B6 110 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 3 System: RCS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV3RCSPH11Y0039 1 H SV3RCSPLW023/B5 SV3RCSPH11Y0060NE 1 H SV3RCSPLW023/C6 SV3RCSPH11Y0060NW 1 H SV3RCSPLW023/C6 SV3RCSPH11Y0067 1 H SV3RCSPLW01L/D4 SV3RCSPH11Y00811 1 H SV3CVSPLW188/D6 SV3RCSPH11Y00812 1 H SV3CVSPLW188/D6 SV3RCSPH11Y0082 1 H SV3RCSPLW028/C5 SV3RCSPH11Y0090 1 H SV3PXSPLW050/C3 SV3RCSPH11Y0103 1 H SV3RCSPLW043/C4 SV3RCSPH11Y0112 1 H SV3RCSPLW016/B5 SV3RCSPH11Y0388 1 H SV3RCSPLW030/D3 SV3RCSPH11Y0391 1 H SV3RCSPLW03D/D3 SV3RCSPH11Y0528 1 H SV3RCSPLW01K/D6 SV3RCSPH11Y0810 1 H SV3RCSPLW080/B5 SV3RCSPH11Y0811 1 H SV3RCSPLW080/B4 SV3RCSPH11Y0813 1 H SV3RCSPLW070/B4 SV3RCSPH11Y1127 1 H SV3RCSPLW021/C5 SV3RCSPH11Y1130 1 H SV3RCSPLW024/C4 SV3RCSPH11Y1132 1 H SV3RCSPLW023/B5 SV3RCSPH11Y1134 1 H SV3RCSPLW023/B6 SV3RCSPH11Y1140 1 H SV3RCSPLW029/B6 SV3RCSPH11Y1141 1 H SV3RCSPLW023/C6 SV3RCSPH11Y1144 1 H SV3CVSPLW182/B4 SV3RCSPH11Y2005 1 H SV3RCSPLW015/C5 SV3RCSPH11Y2101 1 H SV3RCSPLW01F/B5 111 Southern Nuclear Version 3.0

System: RCS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV3RCSPH11Y2106 1 H SV3RCSPLW03B/D3 SV3RCSPH11Y2107 1 H SV3RCSPLW03A/D3 SV3RCSPH11Y2264 1 H SV3RCSPLW028/B6 SV3RCSSSE03A1 1 H SV3PH01V1001/G7 & F4 SV3RCSSSE03A2 1 H SV3PH01V1001/G7 & F4 SV3RCSSSE03B1 1 H SV3PH01V1001/G7 & F4 SV3RCSSSE03B2 1 H SV3PH01V1001/G7 & F4 112 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 3 System: RNS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV3RNSPH12Y2060 3 H SV3RNSPLW091/C6 113 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 3 System: SGS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV3SGSPH11Y0001 2 H SV3SGSPLW020/C7 SV3SGSPH11Y0002 2 H SV3SGSPLW020/C7 SV3SGSPH11Y0004 2 H SV3SGSPLW020/C5 SV3SGSPH11Y0057 2 H SV3SGSPLW010/C4 SV3SGSPH11Y0058 2 H SV3SGSPLW010/B7 SV3SGSPH11Y0063 2 H SV3SGSPLW010/B7 SV3SGSPH11Y0463LO 2 H SV3SGSPLW030/B6 SV3SGSPH11Y0463UP 2 H SV3SGSPLW030/B6 SV3SGSPH11Y0464 2 H SV3SGSPLW030/A5 SV3SGSPH11Y0470 2 H SV3SGSPLW040/B6 SV3SGSPH11Y2002NW 2 H SV3SGSPLW030/B/C6 SV3SGSPH11Y2002NE 2 H SV3SGSPLW030/B/C6 SV3SGSPH11Y2021NW 2 H SV3SGSPLW030/B6 SV3SGSPH11Y2021SW 2 H SV3SGSPLW030/B6 SV3SGSPH11Y3101 2 H SV3SGSPLW040/B5/6 SV3SGSPH11Y3102 2 H SV3SGSPLW040/C6 SV3SGSPH11Y3121NW 2 H SV3SGSPLW040/B6 SV3SGSPH11Y3121NE 2 H SV3SGSPLW040/B6 SV3SGSPH11Y7057 2 H SV3SGSPLW040/C6 SV3SGSPH12Y0108UP 3 H SV3SGSPLW140/D4 SV3SGSPH12Y0108DN 3 H SV3SGSPLW140/D4 SV3SGSPH12Y0136UP 3 H SV3SGSPLW130/D4 SV3SGSPH12Y0136DN 3 H SV3SGSPLW130/D4 SV3SGSPH12Y0507UP 2 H SV3SGSPLW140/C5 SV3SGSPH12Y0507DN 2 H SV3SGSPLW140/C5 114 Southern Nuclear Version 3.0

System: SGS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV3SGSPH12Y0510UP 2 H SV3SGSPLW130/C5 SV3SGSPH12Y0510DN 2 H SV3SGSPLW130/C5 SV3SGSPH12Y7056 2 H SV3SGSPLW130/B6 SV3SGSPH12Y7058 2 H SV3SGSPLW140/B6 115 Southern Nuclear Version 3.0

12.0 VEGP4 DYNAMIC RESTRAINTS TABLES 116 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 4 System: CVS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV4CVSPH11Y02621 3 H SV4CVSPLW171/D4 SV4CVSPH11Y02622 3 H SV4CVSPLW171/D4 SV4CVSPH11Y0268 1 H SV4CVSPLW188/C4 SV4CVSPH11Y2040 1 H SV4CVSPLW171/C5 SV4CVSPH11Y2223 1 H SV4CVSPLW171/C5 SV4CVSPH11Y2224 1 H SV4CVSPLW171/C4 SV4CVSPH11Y2227 3 H SV4CVSPLW171/C3 SV4CVSPH11Y2229 1 H SV4CVSPLW182/C6 SV4CVSPH11Y2263 N H SV4CVSPLW091/C4 SV4CVSPH11Y2265 N H SV4CVSPLW091/B6 .

SV4CVSPH11Y2266 N H SV4CVSPLW091/B6 SV4CVSPH11Y7074 3 H SV4CVSPLW187/B5 117 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 4 System: PXS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV4PXSPH11Y0020 1 H SV4PXSPLW01Q/C5 SV4PXSPH11Y0578 3 H SV4PXSPLW01Z/C5 SV4PXSPH11Y2052 3 H SV4PXSPLW02E/C5/6 SV4PXSPH11Y2057 3 H SV4PXSPLW015/C5 SV4PXSPH11Y2059 3 H SV4PXSPLW01H/B6 118 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 4 System: RCS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV4RCSPH11Y0039 1 H SV4RCSPLW023/B5 SV4RCSPH11Y0060NE 1 H SV4RCSPLW023/C6 SV4RCSPH11Y0060NW 1 H SV4RCSPLW023/C6 SV4RCSPH11Y0067 1 H SV4RCSPLW01L/D4 SV4RCSPH11Y00811 1 H SV4CVSPLW188/D6 SV4RCSPH11Y00812 1 H SV4CVSPLW188/D6 SV4RCSPH11Y0082 1 H SV4RCSPLW028/C5 SV4RCSPH11Y0090 1 H SV4PXSPLW050/C3 SV4RCSPH11Y0103 1 H SV4RCSPLW043/C4 SV4RCSPH11Y0112 1 H SV4RCSPLW016/B5 SV4RCSPH11Y0388 1 H SV4RCSPLW030/D3 SV4RCSPH11Y0391 1 H SV4RCSPLW03D/D3 SV4RCSPH11Y0528 1 H SV4RCSPLW01K/D6 SV4RCSPH11Y0810 1 H SV4RCSPLW080/B5 SV4RCSPH11Y0811 1 H SV4RCSPLW080/B4 SV4RCSPH11Y0813 1 H SV4RCSPLW070/B4 SV4RCSPH11Y1127 1 H SV4RCSPLW021/C5 SV4RCSPH11Y1130 1 H SV4RCSPLW024/C4 SV4RCSPH11Y1132 1 H SV4RCSPLW023/B5 SV4RCSPH11Y1134 1 H SV4RCSPLW023/B6 SV4RCSPH11Y1140 1 H SV4RCSPLW029/B6 SV4RCSPH11Y1141 1 H SV4RCSPLW023/C6 SV4RCSPH11Y1144 1 H SV4CVSPLW182/B4 SV4RCSPH11Y2005 1 H SV4RCSPLW015/C5 SV4RCSPH11Y2101 1 H SV4RCSPLW01F/B5 119 Southern Nuclear Version 3.0

System: RCS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV4RCSPH11Y2106 1 H SV4RCSPLW03B/D3 SV4RCSPH11Y2107 1 H SV4RCSPLW03A/D3 SV4RCSPH11Y2264 1 H SV4RCSPLW028/B6 SV4RCSSSE03A1 1 H SV4PH01V1001/G7 & F4 SV4RCSSSE03A2 1 H SV4PH01V1001/G7 & F4 SV4RCSSSE03B1 1 H SV4PH01V1001/G7 & F4 SV4RCSSSE03B2 1 H SV4PH01V1001/G7 & F4 120 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 4 System: RNS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV4RNSPH12Y2060 3 H SV4RNSPLW091/C6 121 Southern Nuclear Version 3.0

Vogtle Electric Generating Plant - Units 3&4 Dynamic Restraint Table Unit 4 System: SGS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV4SGSPH11Y0001 2 H SV4SGSPLW020/C7 SV4SGSPH11Y0002 2 H SV4SGSPLW020/C7 SV4SGSPH11Y0004 2 H SV4SGSPLW020/C5 SV4SGSPH11Y0057 2 H SV4SGSPLW010/C4 SV4SGSPH11Y0058 2 H SV4SGSPLW010/B7 SV4SGSPH11Y0063 2 H SV4SGSPLW010/B7 SV4SGSPH11Y0463LO 2 H SV4SGSPLW030/B6 SV4SGSPH11Y0463UP 2 H SV4SGSPLW030/B6 SV4SGSPH11Y0464 2 H SV4SGSPLW030/A5 SV4SGSPH11Y0470 2 H SV4SGSPLW040/B6 SV4SGSPH11Y2002NW 2 H SV4SGSPLW030/B/C6 SV4SGSPH11Y2002NE 2 H SV4SGSPLW030/B/C6 SV4SGSPH11Y2021NW 2 H SV4SGSPLW030/B6 SV4SGSPH11Y2021SW 2 H SV4SGSPLW030/B6 SV4SGSPH11Y3101 2 H SV4SGSPLW040/B5/6 SV4SGSPH11Y3102 2 H SV4SGSPLW040/C6 SV4SGSPH11Y3121NW 2 H SV4SGSPLW040/B6 SV4SGSPH11Y3121NE 2 H SV4SGSPLW040/B6 SV4SGSPH11Y7057 2 H SV4SGSPLW040/C6 SV4SGSPH12Y0108UP 3 H SV4SGSPLW140/D4 SV4SGSPH12Y0108DN 3 H SV4SGSPLW140/D4 SV4SGSPH12Y0136UP 3 H SV4SGSPLW130/D4 SV4SGSPH12Y0136DN 3 H SV4SGSPLW130/D4 SV4SGSPH12Y0507UP 2 H SV4SGSPLW140/C5 SV4SGSPH12Y0507DN 2 H SV4SGSPLW140/C5 122 Southern Nuclear Version 3.0

System: SGS Pipe Snubber ID Class Type Iso. Drawing/Coord Alt/CC Comments/Notes SV4SGSPH12Y0510UP 2 H SV4SGSPLW130/C5 SV4SGSPH12Y0510DN 2 H SV4SGSPLW130/C5 SV4SGSPH12Y7056 2 H SV4SGSPLW130/B6 SV4SGSPH12Y7058 2 H SV4SGSPLW140/B6 123 Southern Nuclear Version 3.0

13.0 REFERENCE LIST 13.1 General References 13.1.1 ASME Operation and Maintenance of Nuclear Power Plants Code, 2012 Edition (ASME OM2012) 13.1.2 Vogtle 3&4 Updated Final Safety Analysis Report, Revision 7.0 13.1.3 Appendix A, Vogtle Electric Generating Plant, Units 3 and 4 Technical Specifications, Amendment 72 (Unit 3), Amendment 71 (Unit 4).

13.1.4 LDCR2017070, Main Control Room Emergency Habitability System (VES) Changes to Satisfy PostActuation Performance Requirements (LAR17001) [Design Change Package, APPGWGEE4733, Revision 0]

13.1.5 Corrective Action Request 50001849 13.1.6 Letter from Peter C. Hearn (NRC) to Brian H. Whitley (SNC),

Subject:

VOGTLE ELECTRIC GENERATING PLANT UNITS 3 AND 4 REQUEST FOR ALTERNATIVE: ALTERNATIVE REQUIREMENT FOR PRESERVICE TESTING OF EXPLOSIVELY ACTIVATED VALVES (VEGP 3

& 4PSTALT01) (EPID NO. L2018LLA0498), dated 3/26/2019 13.1.7 Letter from Peter C. Hearn (NRC) to Brian H. Whitley (SNC),

Subject:

VOGTLE ELECTRIC GENERATING PLANT UNITS 3 AND 4 REQUEST FOR ALTERNATIVE: ALTERNATIVE REQUIREMENT FOR PRESERVICE TESTING OF CLASS 1 SAFETY VALVES (VEGP 3 & 4PST ALT02) (EPID L2019LLR0025), dated 5/28/2019 13.2 System Specification Documents 13.2.1 SV3CASM3001, AP1000 Compressed and Instrument Air System (CAS) System Specification Document, Revision 0 [APPCASM3001, Rev. 2]

13.2.2 APPCCSM3001, AP1000 Component Cooling WaterSystem Description Document, Revision 4 13.2.3 APPCVSM3001, AP1000 Chemical and Volume Control System (CVS) System Specification Document, Revision 7 13.2.4 APPDWSM3001, Demineralized Water Transfer and Storage System (DWS), System Specification Document, Revision 0 13.2.5 APPFHSM3001, AP1000 Fuel Handling System System Specification Document, Revision 3 13.2.6 APPFPSM3001, AP1000 Fire Protection System System Specification Document, Revision E 13.2.7 APPMSSM3001, AP1000 Main Steam System Specification Document, Revision 3 13.2.8 APPMTSM3001, AP1000 Main Turbine System System Specification Document, Revision 4 13.2.9 APPPCSM3001, Passive Containment Cooling System System Specification Document, Revision 7 13.2.10 APPPSSM3001, AP1000 Primary Sampling System System Specification Document, Revision 5 13.2.11 APPPWSM3001, AP1000 Potable Water System (PWS) System Specification Document, Revision 1 13.2.12 APPPXSM3001, Passive Core Cooling System, System Specification Document, Revision 10 13.2.13 APPRCSM3001, Reactor Coolant System, System Specification Document, Revision 12 124 Southern Nuclear Version 3.0

13.2.14 APPRNSM3001, Normal Residual Heat Removal System System Specification Document, Revision 5 13.2.15 APPSDSM3001, Sanitary Drainage System (SDS) System Specification Document, Revision 1 13.2.16 APPSFSM3001, AP1000 Spent Fuel Pool Cooling System System Specification Document, Revision 7 13.2.17 APPSGSM3001, Steam Generator System (SGS) System Specification Document, Revision 7 13.2.18 APPVBSM3001, Nuclear Island Nonradioactive Ventilation System, System Specification Document, Revision D 13.2.19 APPVESM3001, AP1000 Main Control Room Emergency Habitability System (VES),

System Specification Document, Revision 4 13.2.20 APPVFSM3001, Containment Air Filtration System, System Specification Document, Revision 0 13.2.21 APPVUSM3001, AP1000 Containment Leak Rate Test System System Specification Document, Revision 2 13.2.22 APPVWSM3001, Central Chilled Water System System Specification Document, Revision D 13.2.23 APPWLSM3001, AP1000 Plant Liquid Radwaste System System Specification Document, Revision 8 13.3 Piping and Instrumentation Diagrams 13.3.1 SV3CASM6005, Revision 3 13.3.2 SV3CASM6012, Revision 3 13.3.3 SV3CCSM6002, Revision 5 13.3.4 SV3CVSM6001, Revision 6 13.3.5 SV3CVSM6003, Revision 6 13.3.6 SV3CVSM6004, Revision 5 13.3.7 SV3CVSM6005, Revision 3 13.3.8 SV3DWSM6007, Revision 2 13.3.9 SV3FPSM6004, Revision 6 13.3.10 SV3MSSM6001, Revision 1 13.3.11 SV3MTSM6002, Revision 4 13.3.12 SV3PCSM6001, Revision 5 13.3.13 SV3PCSM6002, Revision 4 13.3.14 SV3PCSM6003, Revision 2 13.3.15 SV3PSSM6001, Revision 5 13.3.16 SV3PWSM6002, Revision 5 13.3.17 SV3PXSM6001, Revision 3 13.3.18 SV3PXSM6002, Revision 5 13.3.19 SV3PXSM6003, Revision 4 13.3.20 SV3PXSM6004, Revision 2 13.3.21 SV3PXSM6005, Revision 0 13.3.22 SV3RCSM6001, Revision 5 13.3.23 SV3RCSM6002, Revision 7 13.3.24 SV3RCSM6003, Revision 4 13.3.25 SV3RCSM6004, Revision 4 125 Southern Nuclear Version 3.0

13.3.26 SV3RCSM6005, Revision 1 13.3.27 SV3RNSM6001, Revision 4 13.3.28 SV3SDSM6001, Revision 2 13.3.29 SV3SFSM6001, Revision 6 13.3.30 SV3SGSM6001, Revision 6 13.3.31 SV3SGSM6002, Revision 6 13.3.32 SV3VBSM6002, Revision 6 13.3.33 SV3VBSM6007, Revision 8 13.3.34 SV3VESM6001, Revision 1 13.3.35 SV3VESM6002, Revision 4 13.3.36 SV3VFSM6001, Revision 6 13.3.37 SV3VUSM6001, Revision 2 13.3.38 SV3VWSM6003, Revision 3 13.3.39 SV3WLSM6001, Revision 3 13.3.40 SV3WLSM6007, Revision 5 13.3.41 SV4CASM6005, Revision 4 13.3.42 SV4CASM6012, Revision 4 13.3.43 SV4CCSM6002, Revision 5 13.3.44 SV4CVSM6001, Revision 5 13.3.45 SV4CVSM6003, Revision 5 13.3.46 SV4CVSM6004, Revision 4 13.3.47 SV4CVSM6005, Revision 3 13.3.48 SV4DWSM6007, Revision 2 13.3.49 SV4FPSM6004, Revision 6 13.3.50 SV4MSSM6001, Revision 1 13.3.51 SV4MTSM6002, Revision 4 13.3.52 SV4PCSM6001, Revision 5 13.3.53 SV4PCSM6002, Revision 4 13.3.54 SV4PCSM6003, Revision 2 13.3.55 SV4PSSM6001, Revision 5 13.3.56 SV4PWSM6002, Revision 5 13.3.57 SV4PXSM6001, Revision 4 13.3.58 SV4PXSM6002, Revision 6 13.3.59 SV4PXSM6003, Revision 4 13.3.60 SV4PXSM6004, Revision 2 13.3.61 SV4PXSM6005, Revision 0 13.3.62 SV4RCSM6001, Revision 6 13.3.63 SV4RCSM6002, Revision 7 13.3.64 SV4RCSM6003, Revision 4 13.3.65 SV4RCSM6004, Revision 4 13.3.66 SV4RNSM6001, Revision 4 13.3.67 SV4SDSM6001, Revision 2 13.3.68 SV4SFSM6001, Revision 6 13.3.69 SV4SGSM6001, Revision 6 13.3.70 SV4SGSM6002, Revision 6 13.3.71 SV4VBSM6002, Revision 6 126 Southern Nuclear Version 3.0

13.3.72 SV4VBSM6007, Revision 8 13.3.73 SV4VESM6001, Revision 1 13.3.74 SV4VESM6002, Revision 4 13.3.75 SV4VFSM6001, Revision 6 13.3.76 SV4VUSM6001, Revision 2 13.3.77 SV4VWSM6003, Revision 3 13.3.78 SV4WLSM6001, Revision 2 13.3.79 SV4WLSM6007, Revision 4 127 Southern Nuclear Version 3.0