Letter Sequence Request |
|---|
|
|
MONTHYEARML24067A1282024-02-27027 February 2024 Initial Submittal of the Safety Analysis Report for Docket No. 71-9384 Project stage: Request ML24089A2562024-04-0101 April 2024 NRC Approval of Robatel Technologies, LLC Request for Withholding Information from Public Disclosure for the Initial Submittal of the Safety Analysis Report for Docket No. 71-9384 - Enterprise Project Identification Number L-2024-NEW-0003 Project stage: Withholding Request Acceptance ML24145A1342024-06-0505 June 2024 Cover Letter Application for Certificate of Compliance for the Model RT-200 Type B(U) Cask - Accepted for Review Project stage: Other ML24145A1362024-06-0505 June 2024 Enclosure 2 Observations Robatel RT-200 Type B(U) Cask - NON-PROPRIETARY Project stage: Other ML24222A7182024-08-30030 August 2024 Cover Letter - Requests for Additional Information Robatel RT-200 Type B(U) Cask, Docket No. 71-9384 Project stage: RAI ML24222A7192024-08-30030 August 2024 Enclosure 2 - Request for Additional Information Robatel RT-200 Type B(U) Cask - Non-Proprietary Project stage: RAI ML24312A2212024-10-0101 October 2024 Extension Request - Robatel Technologies’ Response to U.S. NRC Request for Additional Information for Review of the Robatel Technologies, LLC Model No. RT-200 Type B(U) Cask - Cac/Epid Numbers: 001029/L-2024-NEW-0003 Project stage: Request ML25062A0932025-02-28028 February 2025 Robatel Technologies, LLC, Submittal of the Revised Safety Analysis Report Project stage: Request ML25150A2982025-05-30030 May 2025 Robatel Technologies, LLC, Submittal of the Revised Safety Analysis Report Project stage: Request ML25150A3562025-06-13013 June 2025 Enclosure 1 - CoC 71-9384 Final Project stage: Other ML25150A3582025-06-13013 June 2025 Enclosure 2 - RT-200 SER R0 Final Project stage: Other ML25150A3572025-06-13013 June 2025 Robatel Technologies RT-200 SER and CoC Cover Letter Docket 71-9384 Project stage: Other ML25160A1682025-06-16016 June 2025 Request for Additional Information (RAI)-10638 by the Office of Nuclear Reactor Regulation Framatome EPID L-2024-NEW-0003 . 0, Txs Compact Platform Topical Report Project stage: RAI 2024-08-30
[Table View] |
Text
Page 1 of 1 5115 Bernard Drive x Suite 304 x Roanoke, VA 24018 540-989-2878 www.robateltech.com October 30, 2024 2021-034-SCL-02 ATTN: Document Control Desk Director, Division of Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Submittal of the Revised Safety Analysis Report for Docket No. 71-9384 Need by Date:
08/07/2025
Reference:
RT-200 Type B(U) Transportation Cask Docket No. 71-9384 Document Control Desk,
Dear Sir or Madam:
Pursuant to 10 CFR 71.38, Robatel Technologies, LLC hereby submits its Safety Analysis Report (SAR)
Revision 1, which has been updated in response to the Requests for Additional Information received on August 30, 2024 (ML24222A718).
Some of the content of the Safety Analysis Report is Robatels proprietary and trade secret information.
The exact details and references are made in the attached affidavit related to this submittal.
Should you or members of your staff have any questions about this submittal, please contact me at jhorin@robateltech.com or Jared Bower at jbower@robateltech.com.
Thank you for your attention to this submittal.
Respectfully, Jay Horin Project Manager/Senior Engineer Robatel Technologies, LLC jhorin@robateltech.com Attachments:
- 1) Affidavit RT-200 SAR REV 1, concerning confidential information and trade secrets
Enclosures:
- 1) RT-200 Safety Analysis Report Rev 1 (PUBLIC), Dated October 2024
- 2) RT-200 Safety Analysis Report Rev 1 (PROPRIETARY), Dated October 2024
- 3) RT-200 RAI Response (PUBLIC), Dated October 30, 2024
- 4) RT-200 RAI Response (PROPRIETARY), Dated October 30, 2024